Snapshot
Ok on Dimmer
Outdoor OK
DMX-800
Constellation™
Sound Activated
DMX512
Master/Slave
115V/230V Switch
Replaceable Fuse
User Serviceable
Duty Cycle
USER MANUAL
Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
Download from Www.Somanuals.com. All Manuals Search And Download.
1. BEFORE YOU BEGIN
What is included
¾
¾
¾
¾
¾
1 x Constellation™
1 x HMI 575W Lamp
Power Cord
Warranty Card
User Manual
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
AC Power
To determine the power requirements for a particular fixture, see the label affixed to the back plate of
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
channel is used solely for a 0% to 100% switch. Before applying power to a
fixture, check that the source voltage matches the fixture’s requirement.
Check the fixture or device carefully to make sure that if a voltage selection
switch exists that it is set to the correct line voltage you will use.
Figure 1 - AC Voltage Switch
Warning!
Verify that the voltage select switch on your unit matches the
line voltage applied. Damage to your fixture may result if the
line voltage applied does not match the voltage indicated on
the voltage selector switch. All fixtures must be connected to
circuits with a suitable Earth Ground.
Not all fixtures have a voltage
select switch. Please be sure to
connect to the proper voltage.
Contact Us
World Wide
General Information
Chauvet Lighting
3000 North 29th Court
Hollywood, FL 33020
voice: 954.929.1115
fax:
954.929.5560
toll free: 800.762.1084
Technical Support
Chauvet Lighting
3000 North 29th Court
Hollywood, FL 33020
voice: 954.929.1115 (Press 4)
fax:
954.929.5560 (Attention: Service)
World Wide Web
Constellation User Manual
3
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Instructions
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance of this
product.
•
•
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that
they also receive this instruction booklet.
Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher than that stated on the decal or rear panel of the fixture.
•
•
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
•
•
•
•
•
The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent
surfaces. Be sure that no ventilation slots are blocked.
Always disconnect from power source before servicing or replacing lamp or fuse and be sure to
replace with same lamp source.
Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use
its carrying handles.
Maximum ambient temperature (Ta) is 95°F (35°C). Do not operate fixture at temperatures higher
than this.
In the event of a serious operating problem, stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Always use the same type spare parts.
•
•
•
•
Don’t connect the device to a dimmer pack.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Avoid direct eye exposure to the light source while it is on.
Caution!
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET at: 954-929-1115.
Constellation User Manual
4
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
2. INTRODUCTION
Features
•
•
•
•
•
•
13 or 19-channel DMX-512 centerpiece
Pan: 180° / tilt: 90° (each mirror)
Pan/tilt control of each mirror individually
Mechanical dimmer/shutter/strobe
Blackout, reset, sound activation and built-in automatic programs via DMX
6 rotating gobo wheels
7 glass, rotating gobos + open on each wheel
Rotating gobo wheel spin effect for each wheel
Remote fixture reset, lamp on/off and vector control channel
•
Additional Features
•
•
•
•
•
•
•
Built-in automated programs via master/slave or DMX
Built-in sound activated programs via master/slave or DMX
Centrally-located lamp holder for easy lamp changes
Micro-stepping motors
LED display
Thermal switch
Fan cooled
DMX Channel Summary
CHANNEL FUNCTION (19 CHANNEL MODE)
CHANNEL FUNCTION (13 CHANNEL MODE)
Pan 1
Pan 1 & 4
1
1
Tilt 1
Tilt 1 & 4
2
2
Pan 2
Pan 2 & 5
3
3
Tilt 2
Tilt 2 & 5
4
4
Pan 3
Pan 3 & 6
5
5
Tilt 3
Tilt 3 & 6
6
6
Pan 4
Vector Speed
7
7
Tilt 4
Shutter/Strobe
8
8
Pan 5
Gobo 1 & 4
9
9
Tilt 5
Gobo 2 & 5
10
11
12
13
14
15
16
17
18
19
10
Pan 6
Gobo 3 & 6
11
Tilt 6
Gobo Rotate
12
Vector Speed
Shutter/Strobe
Gobo 1 & 4
Lamp On/Off, Reset & Auto Modes
13
Gobo 2 & 5
Gobo 3 & 6
Gobo Rotate
Lamp On/Off, Reset & Auto Modes
Constellation User Manual
5
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Overview
Scanning
Head
Safety Hook
Scanning
Head
Scanning
Head
Lamp
Access
Cover
Scanning
Head
Scanning
Head
Scanning
Head
Top of Unit
Microphone
DMX Input
Connector
DMX Output
Connector
Blackout
Controller
Jack
Power/DMX
Indicator
Control Panel
Top of Unit
IEC Power
Connector
Main Fuse
Secondary
Fuse
Constellation User Manual
6
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
3. SETUP
Lamp
You will need to install a lamp prior to the initial operation of the fixture. A 575W HMI lamp is included.
Warning!
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp
with alcohol and wipe it with a lint free cloth before installation.
Lamp Installation
1) Remove the three screws on the
lamp cover plate as indicated in
figure A.
2) Remove the two thumbscrews and
the metal strip shown in figure B.
Figure A
3) Unscrew the lamp from the socket
by turning it counter-clockwise
(figure C).
4) While holding the new lamp with a
lint-free cloth, screw the lamp into
the socket.
5) Replace the two thumbscrews and
the metal strip.
6) Replace the lamp cover plate.
Figure B
Figure C
Constellation User Manual
7
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.
Fuse Replacement
The fuse is located
inside this
compartment.
Remove using a flat
head screwdriver.
With a flat-head screwdriver, unscrew the
fuse holder from its housing. Remove the
damaged fuse from its holder and replace
with exact same type fuse. Screw the fuse
holder back in its place and reconnect power.
FUSE
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller
or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The
combined number of channels required by all the fixtures on a serial data link determines the number
of fixtures the data link can support.
Important:
Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485
standard no more than 32 devices should be connected on one data link. Connecting more than 32
fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in
deterioration of the digital DMX signal.
Maximum recommended serial data link distance: 500 meters (1640 ft.)
Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own
cable please use data-grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
DMX DATA CABLE
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications.
Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will
have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor and shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance: 100 – 140 ohms
Constellation User Manual
8
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
Resistance 120
ohm 1/4w between
pin 2 (DMX -) and
pin 3 (DMX +) of
the last fixture.
DMX connector configuration
1
3
2
COMMON
DMX +
1
1
3
INPUT
3
OUTPUT
Termination reduces signal errors and
to avoid signal transmission problems
and interference, it is always
advisable to connect a DMX signal
terminator.
2
2
DMX -
CAUTION
Do not allow contact between the common and the fixture’s chassis ground. Grounding the common
can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to
verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
3-PIN TO 5-PIN CONVERSION CHART
Note!
If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.
CHAUVET Model No: DMX5M, or DMX5F.
The chart below details a proper cable conversion:
3 PIN TO 5 PIN CONVERSION CHART
Conductor
3 Pin Female (output)
5 Pin Male (Input)
Pin 1
Ground/Shield
Pin 1
Data ( - ) signal
Data ( + ) signal
Do not use
Pin 2
Pin 3
Pin 2
Pin 3
Do not use
Do not use
Do not use
Universal DMX Controller
Setting up a DMX Serial Data Link
1. Connect the (male) 3 pin connector side of
the DMX cable to the output (female) 3 pin
connector of the controller.
2. Connect the end of the cable coming from
the controller which will have a (female) 3
pin connector to the input connector of the
next fixture consisting of a (male) 3 pin
connector.
This drawing provides a
general illustration of the
DMX Input/Output panel of
a lighting fixture.
3. Then, proceed to connect from the output
as stated above to the input of the following
fixture and so on.
CHAUVET Certified DMX Data Cables
Order Code
DMX1.5
DMX4.5
DMX10
Description
DMX Cable 1.5m/4.9ft
DMX Cable 4.5m/14.8ft
DMX Cable 10m/32.8ft
Continue the link
Constellation User Manual
9
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
Master/Slave Fixture Linking
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the first fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then,
proceed to connect from the output as stated above to the input of the following fixture and so on.
Often, the setup for Master-Slave
and Standalone operation requires
that the first fixture in the chain be
initialized for this purpose via either
settings in the control panel or DIP-
switches. Secondarily, the fixtures
that follow may also require a slave
setting. Please consult the
“Operating Instructions” section in
this manual for complete instructions
for this type of setup and
configuration.
Mounting
ORIENTATION
This fixture may be mounted in any position provided there is adequate room for ventilation.
RIGGING
Hanging Clamp
It is important never to obstruct the fan or vents pathway. Mount the
fixture using, a suitable “C” or “O” type clamp. Adjust the angle of
the fixture by loosening both knobs and tilting the fixture. After
finding the desired position, retighten both knobs.
•
When selecting installation location, take into consideration lamp
replacement access and routine maintenance.
•
•
Safety cables should always be used.
Note!
Clamp is sold separately.
Never mount in places where the fixture will be exposed to rain, high
humidity, extreme temperature changes or restricted ventilation.
•
Use only heavy duty clamps for this fixture.
Constellation User Manual
10
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
4. OPERATING INSTRUCTIONS
Navigating the Control Panel
Access control panel functions using the three panel
buttons located directly underneath the LCD Display.
Power/DMX
Indicator
Button
Function
Used to access the menu and scroll
through top-level menu items.
<MODE>
Scrolls through menu options in
ascending order
<UP>
Scrolls through menu options in
descending order
<DOWN>
UP DOWN
MODE
The Control Panel LED Display shows the menu items you select from the menu map below. When a
menu function is selected, the display will show immediately the first available option for the selected
menu function. NOTE: the Power/DMX indicator will blink slowly if a signal is detected on the DMX
input connector, and will be solid if no signal is detected.
Press the <MODE> button once to activate the control panel. Pressing the <MODE> button again will
scroll through the different top-level menu options available. Use the <UP> and <DOWN> buttons to
navigate the menu options. To return to the previous option or menu without changing the value,
press the <MODE> button.
Menu Map
Constellation User Manual
11
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Functions
MENU
OPTION
DESCRIPTION
DMX: The fixture will be controlled by a DMX signal coming from a DMX controller.
The starting address must be selected, and can be set using the up and down
buttons.
Slave Unit: Sets the fixture to run in sync with the Master. You must set the first
fixture in the data link to “Master” otherwise nothing will happen.
Sound Active – Master Unit: Sets the fixture to Master status for Master-Slave
operation and the built in programs will be triggered by the sound. No data link is
required; all fixtures can be set to this mode for Stand-alone operation.
Automatic – Master Unit: Sets the fixture to Master status for Master-Slave
operation and the built in programs will be triggered automatically to a pre-
programmed time interval. No data link is required; all fixtures can be set to this mode
for Stand-alone operation.
Blackout – Master Unit: Sets the fixture to Master status for Master-Slave operation
and closes the shutter. No data link is required; all fixtures can be set to this mode for
blackout operation.
13 Channel Mode: Sets the fixture to operate in 13 channel mode.
19 Channel Mode: Sets the fixture to operate in 19 channel mode.
Operation
Stand-Alone Mode (Sound-Active, Auto Mode):
This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto
Mode.
1) Press <MODE/ESC> until
,
, or
is displayed.
2) Use the <UP> and <DOWN> buttons to scroll through until the desired mode is displayed.
is auto mode;
is sound-active.
3) The unit will react to the low frequencies of music via the internal microphone in Sound-Active
mode, or the unit will auto change in Auto Mode.
Master/Slave Mode (Master Sound, Master Auto):
This mode will allow you to link up to 32 units together without a controller.
1) Use standard DMX cables to daisy chain your units together via the DMX connector on the rear
of the units. For longer cable runs we suggest a terminator at the last fixture. For more
information about terminators, see page 9.
2) Choose a unit to function as the master. Press <MODE> until
,
, or
is displayed on the master unit.
3) Use the <UP> and <DOWN> buttons to scroll through until the desired mode is displayed.
is auto mode;
is sound-active.
4) Press <MODE> until,
is displayed on the slave units.
Constellation User Manual
12
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
DMX Mode
This mode allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with
DMX, please read the DMX Primer on page 16.
1) Press <MODE/ESC> until
is displayed.
2) Use the <UP> and <DOWN> buttons to select the desired address.
DMX Channel Values (19-channel mode)
CHANNEL VALUE
FUNCTION (19-CHANNEL MODE)
1
2
000 Ù 255 Pan 1: 128 = halfway point
000 Ù 255 Tilt 1: 128 = halfway point
000 Ù 255 Pan 2: 128 = halfway point
000 Ù 255 Tilt 2: 128 = halfway point
000 Ù 255 Pan 3: 128 = halfway point
000 Ù 255 Tilt 3: 128 = halfway point
000 Ù 255 Pan 4: 128 = halfway point
000 Ù 255 Tilt 4: 128 = halfway point
000 Ù 255 Pan 5: 128 = halfway point
000 Ù 255 Tilt 5: 128 = halfway point
000 Ù 255 Pan 6: 128 = halfway point
000 Ù 255 Tilt 6: 128 = halfway point
000 Ù 255 Vector Speed: (Normal > Slow)
3
4
5
6
7
8
9
10
11
12
13
Dimmer/Shutter
000 Ù 099 Dimmer (0 – 100%)
100 Ù 133 Open
134 Ù 243 Strobe (Fast > Slow)
244 Ù 249 No Function
250 Ù 255 Open
14
15
16
17
000 Ù 255 Gobo 1 & 4
000 Ù 255 Gobo 2 & 5
000 Ù 255 Gobo 3 & 6
Gobo Rotate
000 Ù 016 No Function
18
017 Ù 135 Counter-clockwise (Slow > Fast)
136
No Rotate
137 Ù 255 Clockwise Rotate (Slow > Fast)
Mode
000
No Function
001 Ù 007 Auto 1
008 Ù 015 Auto 2
016 Ù 023 Auto 3
024 Ù 031 Auto 4
032 Ù 039 Auto 5
040 Ù 047 Auto 6
048 Ù 055 Auto 7
056 Ù 063 Auto 8
064 Ù 071 Auto 9
19
072 Ù 079 Auto 10
080 Ù 087 Auto 11
088 Ù 095 Auto 12
096 Ù 103 Auto 13
104 Ù 111 Auto 14
112 Ù 119 Auto 15
120 Ù 127 Auto 16
128 Ù 160 Sound 1
161 Ù 193 Lamp On (after 5 seconds)
194 Ù 226 Lamp off (after 5 seconds)
227 Ù 254 Reset (after 5 seconds)
255
No Function
Constellation User Manual
13
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
DMX Channel Values (13-channel mode)
CHANNEL VALUE
FUNCTION (19-CHANNEL MODE)
1
2
3
4
5
6
7
000 Ù 255 Pan 1 & 4: 128 = halfway point
000 Ù 255 Tilt 1 & 4: 128 = halfway point
000 Ù 255 Pan 2 & 5: 128 = halfway point
000 Ù 255 Tilt 2 & 5: 128 = halfway point
000 Ù 255 Pan 3 & 6: 128 = halfway point
000 Ù 255 Tilt 3 & 6: 128 = halfway point
000 Ù 255 Vector Speed: (Normal > Slow)
Dimmer/Shutter
000 Ù 099 Dimmer (0 – 100%)
100 Ù 133 Open
134 Ù 243 Strobe (Fast > Slow)
244 Ù 249 No Function
250 Ù 255 Open
8
9
000 Ù 255 Gobo 1 & 4
000 Ù 255 Gobo 2 & 5
000 Ù 255 Gobo 3 & 6
10
11
Gobo Rotate
000 Ù 016 No Function
12
017 Ù 135 Counter-clockwise (Slow > Fast)
136
No Rotate
137 Ù 255 Clockwise Rotate (Slow > Fast)
Mode
000
No Function
001 Ù 007 Auto 1
008 Ù 015 Auto 2
016 Ù 023 Auto 3
024 Ù 031 Auto 4
032 Ù 039 Auto 5
040 Ù 047 Auto 6
048 Ù 055 Auto 7
056 Ù 063 Auto 8
064 Ù 071 Auto 9
13
072 Ù 079 Auto 10
080 Ù 087 Auto 11
088 Ù 095 Auto 12
096 Ù 103 Auto 13
104 Ù 111 Auto 14
112 Ù 119 Auto 15
120 Ù 127 Auto 16
128 Ù 160 Sound 1
161 Ù 193 Lamp On (after 5 seconds)
194 Ù 226 Lamp off (after 5 seconds)
227 Ù 254 Reset (after 5 seconds)
255
No Function
Gobo DMX Values
VALUE
GOBO
000 Ù 015
016 Ù 031
032 Ù 047
048 Ù 063
064 Ù 079
080 Ù 095
096 Ù 111
112 Ù 127
128 Ù 191
192 Ù 255
Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo scroll counter-clockwise (Fast > Slow)
Gobo scroll clockwise (Fast > Slow)
Constellation User Manual
14
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
General Troubleshooting
Applies to
Foggers
& Snow
Dimmers
& Chaser
Symptom
Solution(s)
Lights
9
Controllers
Auto shut off
Check fan thermal switch reset
Beam is very dim or
not bright
Clean optical system or replace lamp
Check 220/110v switch for proper setting
9
Breaker/Fuse keeps
blowing
Check total load placed on device
9
9
9
Chase is too slow
Check users manual for speed adjustment
9
9
9
9
Device has no power Check for power on Mains.
Check device’s fuse. (internal and/or external)
Fixture is not
responding
Check DMX Dip switch settings for correct addressing
Check DMX cables
Check polarity switch settings
9
9
Fixture is on but
there is no
movement to the
audio
Make sure you have the correct audio mode on the
control switches. If audio provided via ¼” jack, make
sure a live audio signal exists
9
9
9
9
Adjust sound sensitivity knob
Lamps cuts off
sporadically
Possible bad lamp or fixture is overheating.
Lamp may be at end of its life.
9
9
Light will not come
on after power failure before the electronics in the fixture can kick start it
again, wait 5 to 10 minutes before powering up
Some discharge lamps require a cooling off period
Loss of signal
Use only DMX cables
Install terminator
Note: Keep DMX cables separated from power cables
or black lights.
9
9
Moves slow
No flash
Check 220/110v switch for proper setting
9
9
9
Re-install bulb, may have shifted in shipping
No laser output
No light output
Bounce mirror motor may have shifted during shipping,
readjust
Check slip ring & brushes for contact
Install bulb
Call service technician
9
Relay will not work
Check reset switch
Check cable connections
9
Remote does not
work
Make sure connector is firmly connected to device
9
9
9
Stand alone mode
All Chauvet lighting fixtures featuring stand-alone
functions do not require additional settings, simply
power the fixture and it will automatically enter into this
mode
If you still have a problem after trying the above solutions, please contact CHAUVET Technical
Support at the location on the next page.
Constellation User Manual
15
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Support
Address: Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)
Support (Email): [email protected]
Telephone: (954) 929-1115 - (Press 4)
Fax: (954) 929-5560 - (Attention: Service)
5. APPENDIX
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A
fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user
must assign a starting address on the fixture that indicates the first channel reserved in the controller.
There are many different types of DMX controllable fixtures and they all may vary in the total number
of channels required. Choosing a start address should be planned in advance. Channels should
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is
set incorrectly. You can however, control multiple fixtures of the same type using the same starting
address as long as the intended result is that of unison movement or operation. In other words, the
fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which
the fixtures are connected is not important and has no effect on how a controller communicates to
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET
carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
Constellation User Manual
16
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
General Maintenance
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage
and environment are contributing factors in determining frequency. As a general rule, fixtures should
be cleaned at least twice a month. Dust build up reduces light output performance and can cause
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off
fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Note:
If you are given an RA #, please include the following information on a piece of paper
inside the box:
1) Your name
2) Your address
3) Your phone number
4) The RA #
5) A brief description of the symptoms
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
Constellation User Manual
17
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Specifications
WEIGHT & DIMENSIONS
Length........................................................................................................................... 33.5 in (850 mm)
Width ............................................................................................................................ 31.5 in (800 mm)
Height ........................................................................................................................... 11.8 in (300 mm)
Weight .............................................................................................................................99.2 lbs (45 kg)
POWER
Switch-selectable power settings ..............................................................110V 60Hz AC or 230V 50Hz
Power Consumption................................................................................................................840W Max
Inrush Power .................................................................................................................................. 936W
LIGHT SOURCE
Lamp..............................................................................................................................HMI 575W Lamp
APPROVED LAMPS
Osram™ HMI575/GS ...........................................................................................1000 hr, 6000K, 575W
Philips™ MSI-575/2..............................................................................................1000 hr, 7000K, 575W
Philips™ MSI-575/HR ..........................................................................................1000 hr, 6000K, 575W
PHOTO OPTIC
Beam Angle (each beam)................................................................................................................... 12°
Beam Angle (entire unit)..................................................................................................................... 73°
Pan ................................................................................................................................................... 570°
Tilt..................................................................................................................................................... 270°
Illuminance at 1m ..................................................................................................9,784 fc (105,276 lux)
THERMAL
Maximum ambient temperature.............................................................................................95°F (35°C)
FUSE
Main....................................................................................................20mm Glass 15A 250V Fast Blow
Secondary ............................................................................................20mm Glass 3A 250V Fast Blow
CONTROL & PROGRAMMING
Data input ................................................................................................ locking 3-pin XLR male socket
Data output........................................................................................... locking 3-pin XLR female socket
Data pin configuration ..............................................................................pin 1 shield, pin 2 (-), pin 3 (+)
Protocols........................................................................................................................ DMX-512 USITT
DMX Channels ................................................................................................................................13/19
ORDERING INFORMATION
Constellation..............................................................................................................................DMX-800
WARRANTY INFORMATION
Warranty.............................................................................................................. 2-year limited warranty
Constellation User Manual
18
2007-01-09/10:53
Download from Www.Somanuals.com. All Manuals Search And Download.
|