Overview
Channel Button: Press the Channel button to set
intercom to one of four secure channels or the paging
channel. The default channel for the
intercom is the paging channel where
all four channel lights are lit. An
intercom on a channel can only hear
an intercom on the same channel or
on the paging channel.
The Intercom has up to a 1000' range and allows
multiple simultaneous conversations, using a
900 Mhz secure digital radio link. The intercoms form
an exclusive network and respond only to other
intercoms in the network.
Carton Inventory
Volume: Pressing the Volume button
repeatedly will cycle through volume
levels.
Battery: The AA Alkaline batteries
(not provided) will last up to a year
depending on use (Lithium batteries
recommended for colder
Rubber Pads
(2 in Model RWIS)
environments). When batteries are low
intercom will emit two beeps every ten
minutes.
OPTIONAL
An AC Adapter (not provided) can also
be used to power the intercom. In this case, both the
power and channel lights will remain on.
Intercom (2 in Model RWIS)
Conference Mode: Conference Mode allows multiple
intercoms to participate in a conversation compared
to Normal Mode in which only two intercoms can
communicate. All intercoms must be set to the same
channel or the paging channel to be in Conference
Mode. To put intercom in Conference Mode
set Dipswitch #2 to UP position.
Operation & Features
Channel Lights
Volume Button
1
2
Microphone
Monitor Mode: Monitor Mode is used
to monitor the sound in a specific
room. Place the intercom in the room
that is to be monitored and press and
hold the Talk and Volume buttons until
a tone is heard. Any other networked
intercom can listen to that room. If a
Talk
(Power - On)
Channel Button
AC Adapter
specific channel is selected for Monitor Mode then
only other intercoms on that channel or on the
paging channel can listen. When in Monitor Mode,
the intercom will stay active for 15 minutes then will
shut off to conserve battery power. The Channel
light will begin to flash while in Standby Mode
and the intercom will reactivate for an additional
15 minutes when a sound is heard from the room
being monitored.
Learn Button
Dipswitch #1
Dipswitch #2
On/Off: To turn intercom ON, press any button. To
turn intercom OFF, hold down the Volume button for
5 seconds.
Talk Button: To talk, hold down the Talk button. All
intercoms in the network that are on
the same channel will receive the
Voice Activation Mode (VOX): Voice Activation
signal. Release the Talk button when
done talking and within 10-15 seconds
press and hold the Talk button of a
different intercom to make a secure
channel between the two. Once the
channel is made the other intercoms in
the network cannot hear the conversation.
Mode (VOX) allows a call to be answered without
pressing the Talk button. Once a call is heard on an
intercom which has been set to VOX, a response can
be given by speaking loudly into the intercom. There
will be a slight delay when VOX is first activated by a
voice, but will continue to transmit audio until
the speaking stops. To put intercom into VOX,
place Dipswitch #1 to the UP position.
1
2
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Intercom does not function.
Check batteries in intercom. If using an AC Adapter
ensure that it is plugged in.
Ensure intercom is connected to a network.
See Programming Intercom.
Ensure that intercoms are on the same channel. See
Operation & Features.
Need to clear intercom’s memory.
Press and hold Learn button, an initial beep will be
heard. Continue to hold until a second beep is heard
(about 15 seconds). Ensure other intercoms are not
activated during this time. Intercoms in the network that
are on will signal during the clearing process. Once
memory is clear the intercom can be programmed to a
new network.
Intercom is not getting expected transmission
range.
Keep antenna vertical. Keep intercom away from
trees, metal objects and electrical wiring. Cell phones,
cordless phones, or other radio devices may also
limit range.
Static and feedback is heard in intercom.
The intercoms are too close to each other. A cordless
phone, cell phone, or other radio devices can also
cause static.
Intercom is sending audio while no buttons are
pressed.
Intercom beeps every ten minutes.
The battery is low in the intercom. Replace with AA
Alkaline batteries or operate it with AC Adapter (not
provided). A 9-12 volt, 500mA AC Adapter may be
used (center positive polarity on the round plug).
The sending intercom is set to Monitoring Mode or Voice
Activation Mode and will activate when sound is heard.
It can be taken out of Monitoring Mode by pressing the
Talk button. It can be taken out of Voice Activation Mode
by setting Dipswitch #1 to DOWN position.
See Operation & Features.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER:
1-800-528-9131
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery.
THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards for Home or office use. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
© 2008, The Chamberlain Group Inc.