The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
GARAGE DOOR OPENER
Model PD432DM 1/2 HP
For Residential Use Only
Owner’s Manual
■ Please read this manual and the enclosed safety materials carefully!
■ Fasten the manual near the garage door after installation.
■ The door WILL NOT CLOSE unless The Protector System® is connected and properly aligned.
■ Periodic checks of the opener are required to ensure safe operation.
■ The model number label is located on the front panel of your opener.
Download from Www.Somanuals.com. All Manuals Search And Download.
Preparing your garage door
Before you begin:
•
•
•
Disable locks.
To prevent possible SERIOUS INJURY or DEATH:
Remove any ropes connected to the garage door.
•
•
•
ALWAYS call a trained door systems technician if
garage door binds, sticks, or is out of balance. An
unbalanced garage door may NOT reverse when
required.
NEVER try to loosen, move or adjust garage door,
door springs, cables, pulleys, brackets or their
hardware, ALL of which are under EXTREME
tension.
Disable ALL locks and remove ALL ropes
connected to garage door BEFORE installing
and operating garage door opener to avoid
entanglement.
Complete the following test to make sure your garage
door is balanced and is not sticking or binding:
1. Lift the door about halfway as shown. Release the
door. If balanced, it should stay in place, supported
entirely by its springs.
2. Raise and lower the door to see if there is any
binding or sticking.
If your door binds, sticks, or is out of balance, call a
trained door systems technician.
To prevent damage to garage door and opener:
•
ALWAYS disable locks BEFORE installing and
operating the opener.
•
ONLY operate garage door opener at 120V, 60 Hz
to avoid malfunction and damage.
Sectional Door
One-Piece Door
Tools needed
During assembly, installation and adjustment of the
opener, instructions will call for hand tools as illustrated
below.
Pencil
Carpenter’s
Level (optional)
2
1
Hack Saw
Tape Measure
Wire Cutters
Drill
3/16", 5/16"
and 5/32" Drill Bits
Claw Hammer
Pliers
1/2" and 3/8" Sockets
and Wrench
Screwdriver
Stepladder
Adjustable End Wrench
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning
Identify the type and height of your garage door. Survey
your garage area to see if any of the conditions below
apply to your installation. Additional materials may be
required. You may find it helpful to refer back to this page
and the accompanying illustrations as you proceed with
the installation of your opener.
•
•
Do you have an access door in addition to the garage
door? If not, Model 7702CB Emergency Key Release is
required. See Accessories page.
Look at the garage door where it meets the floor. Any
gap between the floor and the bottom of the door must
not exceed 1/4" (6 mm). Otherwise, the safety reversal
system may not work properly. See Adjustment Step 3.
Floor or door should be repaired.
Depending on your requirements, there are several
installation steps which may call for materials or hardware
not included in the carton.
•
•
•
•
Installation Step 1 – Look at the wall or ceiling above
the garage door. The header bracket must be securely
fastened to structural supports.
SECTIONAL DOOR INSTALLATIONS
•
Do you have a steel, aluminum, fiberglass or glass
panel door? If so, horizontal and vertical reinforcement
is required (Installation Step 12).
Installation Step 4 – Depending upon garage
construction, extension brackets or wood blocks may
be needed to install sensors.
•
The opener should be installed above the center of the
door. If there is a torsion spring or center bearing plate
in the way of the header bracket, it may be installed
within 4 feet (1.2 m) to the left or right of the door
center. See Installation Steps 1 and 12.
Installation Step 4 – Alternate floor mounting of the
safety reversing sensor will require hardware not
provided.
Installation Step 6 – Do you have a finished ceiling in
your garage? If so, a support bracket and additional
fastening hardware may be required.
SECTIONAL DOOR INSTALLATION
FINISHED CEILING
Support bracket &
fastening hardware
is required.
Horizontal and vertical reinforcement is
needed for lightweight garage doors
(fiberglass, steel, aluminum, door with
glass panels, etc.). See page 23 for details.
See page 19.
Rail
Header Wall
Motor unit
Extension
Spring
Torsion
Spring
OR
Wall-mounted
Door
Control
Access
Door
Vertical
Centerline
of Garage
Door
CLOSED POSITION
Header
Bracket
Rail Assembly
Rail Bracket
Garage
Trolley
Door
Safety Reversing Sensor
Spring
Gap between floor and bottom of
door must not exceed 1/4" (6 mm).
Straight
Emergency
Release
Rope &
Door Arm
Safety Reversing Sensor
Handle
Header
Wall
Curved
Door Arm
Door
Bracket
Garage
Door
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning (Continued)
ONE-PIECE DOOR INSTALLATIONS
Without a properly working safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
•
Generally, a one-piece door does not require
reinforcement. If your door is lightweight, refer to the
information relating to sectional doors in Installation
Step 12.
•
The gap between the bottom of the garage door
and the floor MUST NOT exceed 1/4" (6 mm).
Otherwise, the safety reversal system may not
work properly.
•
Depending on your door’s construction, you may need
additional mounting hardware for the door bracket
(Step 12).
•
The floor or the garage door MUST be repaired to
eliminate the gap.
FINISHED CEILING
ONE-PIECE DOOR WITHOUT TRACK
Support bracket &
fastening hardware
is required.
See page 19.
Rail
Header Wall
Motor unit
Wall-mounted
Door Control
CLOSED POSITION
Access
Door
Header Bracket
Rail Bracket
Rail Assembly
Door
Bracket
Trolley
Emergency
Release
Rope &
Safety Reversing Sensor
Gap between floor and bottom of
door must not exceed 1/4" (6 mm).
Curved
Door Arm
Straight
Door Arm
Garage
Door
Safety Reversing Sensor
Handle
Header
Wall
ONE-PIECE DOOR WITH TRACK
CLOSED POSITION
Rail Bracket
Header Bracket
Trolley
Header
Wall
Access
Door
Curved
Door Arm
Rail Assembly
Door
Bracket
Straight
Door Arm
Garage
Door
Emergency
Release Rope
& Handle
Safety Reversing Sensor
Gap between floor and bottom of
door must not exceed 1/4" (6 mm).
Safety Reversing
Sensor
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Carton Inventory
Your garage door opener is packaged in one carton which
contains the motor unit and all parts illustrated below.
Accessories will depend on the model purchased. If
anything is missing, carefully check the packing material.
PARTS MAY BE STUCK IN THE FOAM. Hardware for
assembly and installation is shown on the next page.
Save the carton and packing material until installation and
adjustment is complete.
Remote Control
Visor Clip
Sprocket Coupling
LOCK
LIGHT
SECURITY✚®
1-Button Remote Control (2)
Multi-Function Door
Control Panel
Rail Support Braces (4)
Motor Unit with 2 Light Lenses
2 Conductor Bell Wire
White & White/Red
Rail Assembly
Straight Door
Arm Section
Trolley
Header/Rail Brackets
Y
ONL
CEILING MOUNT
UP
Curved Door
Arm Section
Header Bracket
Door Bracket
Hanging Brackets
Safety
Labels and
Literature
®
The Protector System
(2) Safety Reversing Sensors
(1 Sending Eye and 1 Receiving Eye)
with 2-Conductor White &
White/Black Bell Wire attached
Safety Reversing
Sensor Bracket (2)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Inventory
Separate all hardware and group as shown below for the assembly and installation procedures.
ASSEMBLY HARDWARE
Wire Clips (6)
Metal Sleeve (2)
Hex Bolt 1/4-20x7/16" (14)
Sprocket Coupling
Sleeve
C-Clip (2)
INSTALLATION HARDWARE
Ring Fastener (3)
Wing Nut
1/4"-20 (2)
Carriage Bolt
1/4"-20x1/2" (2)
Nut 5/16"-18 (6)
Handle
Lag Screw
5/16"-9x1-5/8" (2)
Hex Bolt
5/16"-18x7/8" (4)
Insulated
Staples (30)
Lock Washer
5/16" (6)
Lag Screw
5/16"-18x1-7/8" (2)
Screw 6ABx1-1/4" (2)
Screw 6-32x1" (2)
Drywall Anchors (2)
Spacer
Rope
Clevis Pin
5/16"x2-3/4" (1)
Clevis Pin
5/16"x1-1/4" (1)
Clevis Pin
5/16"x1" (1)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY STEP 1
Assemble the Rail
To prevent INJURY from pinching, keep hands and
fingers away from the joints while assembling the rail.
To avoid installation difficulties, do not run the garage
door opener until instructed to do so.
1. Open the rail carton and remove the contents onto
a level work surface. Keep it clean and free of debris
while you are working.
HARDWARE SHOWN ACTUAL SIZE
2. Identify the rail sections and orient the sections on a
flat surface as shown. The back rail has a black gear on
one end. The header rail has a black plastic rack inside
the rail on the screw. The remaining section is the
center rail.
NOTE: Use caution when handling the center rail section.
The screw can slip out if the section is tipped up too far.
Hex Bolt 1/4-20x7/16"
Remove Cardboard Packing
Hanging Brackets
Rail Support Braces
Rail Assembly
Straight Door Arm
Header Rail
Brackets
Rail Assembly
Remove Cardboard Packing
Sprocket Coupling
Remove Cardboard Packing
Rail Assembly Carton
Hex Bolts
Back Rail
1/4-20x7/16"
Hex Bolts
1/4-20x7/16"
Hex Bolts
1/4-20x7/16"
Center Rail
Hex Bolts
1/4-20x7/16"
Header Rail
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Assemble the Rail (continued)
HARDWARE SHOWN ACTUAL SIZE
3. Attach rail support braces to the back rail. Loosely
insert 1/4-20x7/16" hex bolts into the aligned holes of
the end rail and rail support brace (Figure 1). Do not
finger tighten.
4. Extend the drive screw a few inches from the center
rail, and slide the sleeve onto the long journal
(Figure 2).
Metal Sleeve
C-Clip
5. Interlock the long and short journal of the center and
back rails. Slide the sleeve over the journal connection
(Figure 3).
Hex Bolt 1/4-20x7/16"
6. Place the c-clip onto the long journal shaft (center rail)
to ensure that the sleeve does not slide (Figure 4).
7. Slide the center rail so that the center rail and rail brace
holes are aligned (Figure 5). Secure with bolts.
8. Tighten all hex bolts.
9. Repeat steps 3-8 for header section.
Figure 1
Figure 4
Metal
Sleeve
Rail
Rail Support Brace
C-Clip
Center Rail
Rail Support Brace
Figure 2
Drive Screw
Figure 5
Metal Sleeve
Long Journal
Rail Support Brace
Center Rail
Center Rail
Short Journal
Figure 3
Long Journal
Rail Support Brace
Metal Sleeve
9
Download from Www.Somanuals.com. All Manuals Search And Download.
HARDWARE SHOWN ACTUAL SIZE
ASSEMBLY STEP 2
Fasten the Rail to the Motor Unit and Install
the Trolley
NOTE: To aid in assembly and installation, replace the
foam packing around the motor unit. Remove it after
Installation Step 4.
Hex Bolt 1/4"-20x7/16"
1. Working on a level surface, align the rail assembly with
the motor unit, as shown.
2. Slip the coupling over the rail sprocket.
3. Slide the rail through the motor unit bracket until the
coupling fits securely over the motor unit sprocket.
4. Align the four bolt holes in the rail with those in the
motor unit bracket. Insert four 1/4"-20x7/16" hex bolts.
Tighten securely with a 3/8" socket wrench.
5. Disengage trolley by turning the release arm down.
Slide trolley onto and along the bottom of the rail until
it aligns with the rack. Turn release arm up. This will
join the rack and the trolley.
Motor Unit
Motor Unit
Bracket
Sprocket
Hex Bolts
1/4"-20x7/16"
Coupling
Rail Sprocket
Hex Bolts
1/4"-20x7/16"
Rail Assembly
Foam Packaging
Release Arm
Rack
Trolley
To the motor unit
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Rail Brackets
ASSEMBLY STEP 3
Attach the Rail Brackets
• Align rail brackets to end of rail assembly, as shown.
Hex Bolt
1/4"-20x7/16"
• Insert two 1/4"-20x7/16" hex bolts. Tighten securely
with a 3/8" socket.
Rail
You have now finished assembling your garage door
opener. Please read the following warnings before
proceeding to the installation section.
Hex Bolt
1/4"-20x7/16"
HARDWARE SHOWN ACTUAL SIZE
Hex Bolt 1/4"-20x7/16"
INSTALLATION
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS
AND INSTRUCTIONS.
7. NEVER connect garage door opener to power source
until instructed to do so.
2. Install garage door opener ONLY on properly balanced
and lubricated garage door. An improperly balanced
door may NOT reverse when required and could result
in SEVERE INJURY or DEATH.
3. ALL repairs to cables, spring assemblies and other
hardware MUST be made by a trained door systems
technician BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes connected
to garage door BEFORE installing opener to avoid
entanglement.
5. Install garage door opener 7 feet (2.13 m) or more
above floor.
8. NEVER wear watches, rings or loose clothing while
installing or servicing opener. They could be caught
in garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height of
5 feet (1.5 m).
• away from ALL moving parts of the door.
10. Place entrapment warning label on wall next to
garage door control.
11. Place manual release/safety reverse test label in plain
view on inside of garage door.
12. Upon completion of installation, test safety reversal
system. Door MUST reverse on contact with a 1-1/2"
(3.8 cm) high object (or a 2x4 laid flat) on the floor.
6. Mount the emergency release within reach, but at
least 6 feet (1.83 m) above the floor and avoiding
contact with vehicles to avoid accidental release.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 1
Determine the Header Bracket Location
OPTIONAL
CEILING
MOUNT
FOR
Unfinished Ceiling
HEADER
BRACKET
Header Wall
2x4
Vertical Centerline
of Garage Door
To prevent possible SERIOUS INJURY or DEATH:
•
Header bracket MUST be RIGIDLY fastened to
structural support on header wall or ceiling,
otherwise garage door might not reverse when
required. DO NOT install header bracket over
drywall.
2x4
Structural
Supports
•
•
Concrete anchors MUST be used if mounting
header bracket or 2x4 into masonry.
NEVER try to loosen, move or adjust garage
door, springs, cables, pulleys, brackets, or their
hardware, ALL of which are under EXTREME
tension.
Level
(optional)
•
ALWAYS call a trained door systems technician if
garage door binds, sticks, or is out of balance. An
unbalanced garage door might not reverse when
required.
Installation procedures vary according to garage door
types. Follow the instructions which apply to your door.
Header Wall
3" (7.5 cm)
Header Wall
3" (7.5 cm)
1. Close the door and mark the inside vertical centerline
of the garage door.
Highest
Point of
Travel
Track
Door
Highest
Point of
Travel
2. Extend the line onto the header wall above the door.
Track
You can fasten the header bracket within 4 feet
(1.22 m) of the left or right of the door center only if
a torsion spring or center bearing plate is in the way;
or you can attach it to the ceiling (see page 13) when
clearance is minimal. (It may be mounted on the
wall upside down if necessary, to gain approximately
1/2" (1 cm).)
Door
One-piece door with
horizontal track
Sectional door with
curved track
If you need to install the header bracket on a 2x4
(on wall or ceiling), use lag screws (not provided)
to securely fasten the 2x4 to structural supports as
shown here and on page 13.
Header Wall
8" (20 cm)
Header Wall
3. Open your door to the highest point of travel as shown.
Draw an intersecting horizontal line on the header wall
above the high point:
8" (20 cm)
•
3" (7.5 cm) above the high point for sectional door
and one-piece door with track.
Door
Highest
Point
Door
of Travel
•
8" (20 cm) above the high point for one-piece door
without track.
Jamb
Hardware
Highest
Point
of Travel
This height will provide travel clearance for the top
edge of the door.
Pivot
NOTE: If the total number of inches exceeds the height
available in your garage, use the maximum height
possible, or refer to page 13 for ceiling installation.
One-piece door without track: One-piece door without track:
jamb hardware pivot hardware
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 2
Install the Header Bracket
Wall Mounting Holes
The nail hole is for
positioning only. You
must use lag screws
to mount the header
bracket.
You can attach the header bracket either to the wall above
the garage door, or to the ceiling. Follow the instructions
which will work best for your particular requirements. Do
not install the header bracket over drywall. If installing
into masonry, use concrete anchors (not provided).
WALL HEADER BRACKET INSTALLATION
•
•
Center the bracket on the vertical centerline with the
bottom edge of the bracket on the horizontal line as
shown (with the arrow pointing toward the ceiling).
Optional Wall
Mounting Holes
Vertical Centerline
of Garage Door
Header
Bracket
- Header Wall -
Mark the vertical set of bracket holes (do not use the
holes designated for ceiling mount). Drill 3/16" pilot
holes and fasten the bracket securely to a structural
support with the hardware provided.
2x4
Structural
Support
Lag Screws
5/16"-9x1-5/8"
Door Spring
HARDWARE SHOWN ACTUAL SIZE
Horizontal
Line
- Garage Door -
Vertical Centerline
of Garage Door
Lag Screw
5/16"-9x1-5/8"
Highest Point
of Garage
Door Travel
CEILING HEADER BRACKET INSTALLATION
•
Extend the vertical centerline onto the ceiling as
shown.
•
Center the bracket on the vertical mark, no more than
6" (15 cm) from the wall. Make sure the arrow is
pointing toward the wall. The bracket can be mounted
flush against the ceiling when clearance is minimal.
- Finished Ceiling -
Vertical Centerline
of Garage Door
Header
Bracket
•
Mark the side holes. Drill 3/16" pilot holes and fasten
bracket securely to a structural support with the
hardware provided.
6" (15 cm)
Maximum
Ceiling Mounting Holes
Door
Spring
Lag Screws
5/16"-9x1-5/8"
- Header Wall -
The nail hole is for
positioning only. You
must use lag screws
to mount the header
bracket.
Garage Door
Vertical
Centerline
of Garage
Door
13
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 3
Attach the Rail to the Header Bracket
•
Position the opener on the garage floor below the
header bracket. Use packing material as a protective
base. NOTE: If the door spring is in the way you’ll need
help. Have someone hold the opener securely on a
temporary support to allow the rail to clear the spring.
•
•
Position the header/rail bracket against the header
bracket.
Align the bracket holes and join with a clevis pin
5/16"x2-3/4" as shown. Spacer can be installed on
either side of rail.
•
Insert a ring fastener to secure.
Header Wall
Header Bracket
Header/Rail Bracket
Ring Fastener
Rail
Header Bracket
Spacer
Clevis Pin
5/16"x2-3/4"
Garage Door
Header/Rail Bracket
Rail
Opener Carton
or Temporary
Support
HARDWARE SHOWN ACTUAL SIZE
Clevis Pin
5/16"x2-3/4"
Spacer
Ring Fastener
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 4
®
Install The Protector System
Be sure power is NOT connected to the garage door
opener BEFORE installing the safety reversing sensor.
To prevent SERIOUS INJURY or DEATH from a
closing garage door:
The safety reversing sensor must be connected and
aligned correctly before the garage door opener will
move in the down direction.
•
Correctly connect and align the safety reversing
sensor. This required safety device MUST NOT be
disabled.
IMPORTANT INFORMATION ABOUT
THE SAFETY REVERSING SENSOR
•
Install the safety reversing sensor so beam is NO
HIGHER than 6" (15 cm) above garage floor.
When properly connected and aligned, the sensor will
detect an obstacle in the path of its electronic beam. The
sending eye (with an amber indicator light) transmits an
invisible light beam to the receiving eye (with a green
indicator light). If an obstruction breaks the light beam
while the door is closing, the door will stop and reverse
to full open position, and the opener lights will flash
10 times.
If it is necessary to mount the units on the wall, the
brackets must be securely fastened to a solid surface such
as the wall framing. Extension brackets (see accessories)
are available if needed. If installing in masonry
construction, add a piece of wood at each location to
avoid drilling extra holes in masonry if repositioning is
necessary.
The units must be installed inside the garage so that the
sending and receiving eyes face each other across the
door, no more than 6" (15 cm) above the floor. Either can
be installed on the left or right of the door as long as the
sun never shines directly into the receiving eye lens.
The invisible light beam path must be unobstructed. No
part of the garage door (or door tracks, springs, hinges,
rollers or other hardware) may interrupt the beam while
the door is closing.
The mounting brackets are designed to clip onto the track
of sectional garage doors without additional hardware.
Safety Reversing Sensor Invisible Light Beam
6" (15 cm) max.
above floor
Safety Reversing Sensor
6" (15 cm) max.
above floor
Protection Area
Facing the door from inside the garage
15
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING THE BRACKETS
Figure 1
DOOR TRACK MOUNT (RIGHT SIDE)
Be sure power to the opener is disconnected. Install
and align the brackets so the sensors will face each other
across the garage door, with the beam no higher than 6"
(15 cm) above the floor. They may be installed in one of
three ways, as follows.
Door
Track
Lip
Indicator
Light
Garage door track installation (preferred):
•
Slip the curved arms over the rounded edge of each
door track, with the curved arms facing the door. Snap
into place against the side of the track. It should lie
flush, with the lip hugging the back edge of the track,
as shown in Figure 1.
Safety
Reversing
Sensor
Bracket
Lens
If your door track will not support the bracket securely,
wall installation is recommended.
WALL MOUNT (RIGHT SIDE)
Figure 2
Wall installation (Figure 2 & 3):
Fasten Wood Block to Wall with
Lag Screws (not provided)
•
Place the bracket against the wall with curved arms
facing the door. Be sure there is enough clearance for
the sensor beam to be unobstructed.
Indicator
Safety
Light
Reversing
•
•
If additional depth is needed, an extension bracket (See
Accessories) or wood blocks can be used.
Sensor
Bracket
Use bracket mounting holes as a template to locate
and drill (2) 3/16" diameter pilot holes on the wall at
each side of the door, no higher than 6" (15 cm) above
the floor.
Lag Screws
(not provided)
Lens
•
•
Attach brackets to wall with lag screws (Not provided).
If using extension brackets or wood blocks, adjust
right and left assemblies to the same distance out from
the mounting surface. Make sure all door hardware
obstructions are cleared.
WALL MOUNT (RIGHT SIDE)
Figure 3
Extension Bracket
(See Accessories)
Floor installation (Figure 4):
(Provided with
Extension Bracket)
•
•
•
Use wood blocks or extension brackets (See
Accessories) to elevate sensor brackets so the lenses
will be no higher than 6" (15 cm) above the floor.
Carefully measure and place right and left assemblies
at the same distance out from the wall. Be sure all door
hardware obstructions are cleared.
Fasten to the floor with concrete anchors as shown.
Safety Reversing
Sensor Bracket
(Provided with
Extension Bracket)
Lens
Indicator
Light
HARDWARE SHOWN ACTUAL SIZE
Figure 4
FLOOR MOUNT (RIGHT SIDE)
Attach with
Concrete Anchors
(not provided)
Carriage Bolt
1/4"-20x1/2"
Wing Nut
1/4"-20
Staples
Lens
Indicator
Light
Safety
Reversing
Sensor
Bracket
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5
MOUNTING AND WIRING THE SAFETY SENSORS
•
Slide a 1/4"-20x1/2" carriage bolt head into the slot
on each sensor. Use wing nuts to fasten sensors
to brackets, with lenses pointing toward each other
across the door. Be sure the lens is not obstructed by
a bracket extension. See Figure 5.
Wing Nut
Carriage Bolt
1/4"-20x1/2"
•
Finger tighten the wing nuts.
Recommended Wire Routing
Lens
1. Using insulated staples, run the wires from both
sensors to the rail at the door header (see Figure 6).
HARDWARE SHOWN ACTUAL SIZE
2. Run the wires through wire clip at the top of the rails.
NOTE: If your access door is near the garage door, you
may choose to install the door control at this time and
run the door control wire along the rail with the sensor
wires. If you choose this option, follow instructions
1-3 on page 20.
Carriage Bolt
1/4"-20x1/2"
Wing Nut
1/4"-20
Wire Clip
Staples
Figure 6
Sensor Wire
Wire Clips
Bell Wire
Rail
Safety Reversing Sensor
Invisible Light Beam
Protection Area
Safety Reversing Sensor
17
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 5
Position the Opener
To prevent damage to garage door, rest garage door
opener rail on 2x4 placed on top section of door.
Follow instructions which apply to your door type as
illustrated.
SECTIONAL DOOR OR ONE-PIECE DOOR WITH
TRACK
A 2x4 laid flat is convenient for setting an ideal door-to-
rail distance.
Top of Door
•
•
Remove foam packaging.
Raise the opener onto a stepladder. You will need help
at this point if the ladder is not tall enough.
Door
2x4 is used to determine
the correct mounting
height from ceiling.
•
•
Open the door all the way and place a 2x4 laid flat on
the top section beneath the rail.
If the top section or panel hits the trolley when you
raise the door, pull down on the trolley release arm
to disconnect inner and outer sections. Slide the outer
trolley toward the motor unit. The trolley can remain
disconnected until Installation Step 13 is completed.
Trolley
Release Arm
ENGAGED
RELEASED
ONE-PIECE DOOR WITHOUT TRACK
A 2x4 on its side is convenient for setting an ideal
door-to-rail distance.
•
•
Remove foam packaging.
Raise the opener onto a stepladder. You will need help
at this point if the ladder is not tall enough.
Top of Door
•
•
Open the door all the way and place a 2x4 on its side
on the top section of the door beneath the rail.
2x4 is used to determine
the correct mounting
height from ceiling.
The top of the door should be level with the top of the
motor unit. Do not position the opener more than 4"
(10 cm) above this point.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 6
Hang the Opener
To avoid possible SERIOUS INJURY from a falling
garage door opener, fasten it SECURELY to structural
supports of the garage. Concrete anchors MUST be
used if installing any brackets into masonry.
Three representative installations are shown. Yours may
be different. Hanging brackets should be angled
(Figure 1) to provide rigid support. On finished ceilings
(Figure 2 and Figure 3), attach a sturdy metal bracket
to structural supports before installing the opener. This
bracket and fastening hardware are not provided (see
accessories).
Figure 1
Structural
Supports
Existing brackets from a previous installation may be
fastened to the sides of the motor unit as in Figures 1, 2
and 3. Then continue with step 6 below.
Measure
Lag Screws
Distance
5/16"-18x1-7/8"
1. Measure the distance from each side of the motor unit
to the structural support.
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
2. Cut both pieces of the hanging bracket to required
lengths.
3. Drill 3/16" pilot holes in the structural supports.
4. Attach one end of each bracket to a support with
5/16"-18x1-7/8" lag screws.
5. Fasten the opener to the hanging brackets with
5/16"-18x7/8" hex bolts, lock washers and nuts.
Figure 2
Bracket
(Not Provided)
Hidden Support
6. Check to make sure the rail is centered over the door
(or in line with the header bracket if the bracket is not
centered above the door).
FINISHED CEILING
Lag Screws
5/16"-18x1-7/8"
7. Remove the 2x4. Operate the door manually. If the door
hits the rail, raise the header bracket.
(Not Provided)
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
NOTE: DO NOT connect power to opener at this time.
Nut 5/16"-18
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
HARDWARE SHOWN ACTUAL SIZE
Lag Screw
5/16"-18x1-7/8"
Figure 3
FINISHED CEILING
Lag Screws
5/16"-18x1-7/8"
Hex Bolt
Lock
Nut 5/16"-18
5/16"-18x7/8"
Washer 5/16"
(Not Provided)
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 7
Install the Door Control
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
Locate door control within sight of door at a minimum
height of 5 feet (1.5 m) where small children cannot
reach, and away from moving parts of door and door
hardware. The installation surface must be smooth and
flat. If installing into drywall (Figure 1), drill 5/32" holes
and use anchors provided. For pre-wired installations (as
in new home construction), it may be mounted to a single
gang box (Figure 2). NOTE: After installation, a green or
amber indicator light behind the cover will indicate proper
connection. If not lit, the Lock and Light features will not
function (reverse wires to correct).
•
Be sure power is NOT connected BEFORE installing
door control.
•
Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
•
Install door control within sight of garage door, out
of reach of children at a minimum height of 5 feet
(1.52 m), and away from all moving parts of door.
•
•
NEVER permit children to operate or play with door
control push buttons or remote control transmitters.
Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to
door travel.
1. Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back of
door control by color: white wire to WHT and white/red
wire to the RED (Figure 3).
•
ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of
closing garage door.
2. Remove cover by gently prying on a side corner near the
top of the cover with a small flat head screwdriver
(Figure 4). Fasten with 6ABx1-1/4" self-tapping screws
(drywall installation) or 6-32x1" machine screws (into
gang box) as follows:
HARDWARE SHOWN ACTUAL SIZE
Insulated
Staples
•
•
•
•
Drill and install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
Screw 6ABx1-1/4"
Control Panel (std installation)
Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
Screw 6-32x1"
Control Panel (pre-wired)
Drywall Anchors
Install top screw with care to avoid cracking plastic
housing. Do not overtighten.
STANDARD
INSTALLATION
Figure 2
PRE-WIRED
INSTALLATION
Insert bottom tabs and snap on cover.
Figure 1
NOTE: The push bar may stick if the door control is not
mounted on a smooth surface. If a click is not heard when
pressing the push bar, loosen the two mounting screws
or relocate the door control to a smoother surface.
3. (Standard installation only) Run bell wire up wall and
across ceiling to motor unit. Use insulated staples to
secure wire in several places. Do not pierce wire with a
staple, creating a short or open circuit. If your access
door is near the garage door, you may run this wire with
the Safety Reversing Sensor wires along the top of the
rail. See page 17.
24 Volt
To Replace
Insert Bottom
Tabs First
Bell Wire
To Replace Insert
Bottom Tabs First
Figure 3
MULTI-FUNCTION
WALL CONTROL PANEL
Top Mounting Hole
4. Insert all wires through the opening on top of motor unit
above the terminal block on the back panel (Figure 4).
Figure 4
Terminal
Screws
5. Strip 7/16" (11 mm) of insulation from each set of bell
wires. Connect bell wires to the quick-connect terminals
as follows: white to white and white/red to red; white to
white and white/black to grey (Figure 5).
Bell Wire
Bottom
Mounting Hole
9
1
9
1
7
3
7
3
5
5
KG
KG
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.
To release or insert wire, push
in tab with screwdriver tip
Safety Sensor Connections
Door Control Connections
6. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual
release/safety reverse test label in a prominent location
on inside of garage door.
NOTE: DO NOT connect the power and operate the opener at
this time. The trolley will travel to the full open position but
will not return to the close position until the sensor beam is
connected and properly aligned.
White
Red
Grey
7/16"
(11 mm)
Strip wire 7/16" (11 mm)
20
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 8
Install the Lights
To prevent possible OVERHEATING of the endpanel or
light socket:
•
Press the release tabs on both sides of lens. Gently
rotate lens back and downward until the lens hinge is
in the fully open position. Do not remove the lens.
•
•
DO NOT use short neck or specialty light bulbs.
DO NOT use halogen bulbs. Use ONLY
incandescent.
•
Install a 100 watt maximum light bulb in each socket.
Light bulb size should be A19, standard neck only. The
lights will turn ON and remain lit for approximately
4-1/2 minutes when power is connected. Then the
lights will turn OFF.
To prevent damage to the opener:
•
•
DO NOT use bulbs larger than 100W.
ONLY use A19 size bulbs.
•
•
Reverse the procedure to close the lens.
Use A19, standard neck garage door opener bulbs for
replacement.
100 Watt (Max)
Standard Light Bulb
NOTE: Use only standard light bulbs. The use of short
neck or speciality light bulbs may overheat the endpanel
or light socket.
Release Tab
Lens
Hinge
100 Watt (Max)
Standard Light Bulb
INSTALLATION STEP 9
Attach the Emergency Release Rope and
Handle
To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
•
Thread one end of the rope through the hole in the top
of the red handle so “NOTICE” reads right side up as
shown. Secure with an overhand knot at least
1" (2.5 cm) from the end of the rope to prevent
slipping.
•
If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
•
•
NEVER use emergency release handle unless
garage doorway is clear of persons and
obstructions.
NEVER use handle to pull door open or closed. If
rope knot becomes untied, you could fall.
•
•
Thread the other end of the rope through the hole in
the release arm of the outer trolley.
Adjust rope length so the handle is 6 feet (1.83 m)
above the floor. Ensure that the rope and handle clear
the tops of all vehicles to avoid entanglement. Secure
with an overhand knot.
NOTE: If it is necessary to cut the rope, heat seal the cut
end with a match or lighter to prevent unraveling.
Trolley
Trolley Release Arm
NO
Emergency
TICE
Overhand Knot
Release Handle
21
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 10
Electrical Requirements
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire:
To avoid installation difficulties, do not run the opener
until Step 11 below.
•
•
•
Be sure power is NOT connected to the opener,
and disconnect power to circuit BEFORE removing
cover to establish permanent wiring connection.
Garage door installation and wiring MUST be in
compliance with all local electrical and building
codes.
NEVER use an extension cord, 2-wire adapter, or
change plug in any way to make it fit outlet. Be
sure the opener is grounded.
To reduce the risk of electric shock, your garage door
opener has a grounding type plug with a third grounding
pin. This plug will only fit into a grounding type outlet.
If the plug doesn't fit into the outlet you have, contact a
qualified electrician to install the proper outlet.
RIGHT
WRONG
PERMANENT WIRING
CONNECTION
If permanent wiring is required by your local code, refer
to the following procedure.
Ground Tab
To make a permanent connection through the 7/8" hole in
the top of the motor unit:
Green
Ground
Screw
•
Remove the motor unit cover screws and set the cover
aside.
Black
Wire
•
•
Remove the attached 3-prong cord.
Ground Wire
White Wire
Connect the black (line) wire to the screw on the brass
terminal; the white (neutral) wire to the screw on
the silver terminal; and the ground wire to the green
ground screw. The opener must be grounded.
Black
Wire
White Wire
•
Reinstall the cover.
To avoid installation difficulties, do not run the opener
until Step 11 below.
INSTALLATION STEP 11
Complete the Safety Reversing Sensor
Installation
TROUBLESHOOTING THE SAFETY
REVERSING SENSORS
1. If the sending eye indicator light does not glow steadily
ALIGNING THE SAFETY REVERSING SENSORS
after installation, check for:
•
Plug in the opener. The indicator lights in both the
sending and receiving eyes will glow steadily if wiring
connections and alignment are correct.
•
•
Electric power to the opener.
A short in the white or white/black wires. These can
occur at staples, or at opener connections.
The sending eye amber indicator light will glow regardless
of alignment or obstruction. If the green indicator light in
the receiving eye is off, dim, or flickering (and the invisible
light beam path is not obstructed), alignment is required:
•
•
Incorrect wiring between sensors and opener.
A broken wire.
2. If the sending eye indicator light glows steadily but the
receiving eye indicator light doesn’t:
•
Loosen the sending eye wing nut and readjust, aiming
directly at the receiving eye. Lock in place.
•
•
Check alignment.
•
Loosen the receiving eye wing nut and adjust the
sensor until it receives the sender’s beam. When the
green indicator light glows steadily, tighten the wing
nut.
Check for an open wire to the receiving eye.
3. If the receiving eye indicator light is dim, realign either
sensor.
NOTE: When the invisible beam path is obstructed or
misaligned while the door is closing, the door will reverse.
If the door is already open, it will not close. The opener
lights will flash 10 times. (See page 15.)
22
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 12
Fasten the Door Bracket
Fiberglass, aluminum or lightweight steel garage
doors WILL REQUIRE reinforcement BEFORE
installation of door bracket. Contact your door
manufacturer for reinforcement kit.
Follow instructions which apply to your door type
as illustrated below or on the following page.
A horizontal reinforcement brace should be long enough
to be secured to two or three vertical supports. A
vertical reinforcement brace should cover the height of
the top panel.
Header
Bracket
Figure 1 shows one piece of angle iron as the horizontal
brace. For the vertical brace, 2 pieces of angle iron are
used to create a U-shaped support. The best solution is to
check with your garage door manufacturer for an opener
installation door reinforcement kit.
NOTE: Many door reinforcement kits provide for direct
attachment of the clevis pin and door arm. In this case
you will not need the door bracket; proceed to Step 13.
Door
Bracket
Location
SECTIONAL DOORS
HORIZONTAL AND VERTICAL
REINFORCEMENT IS NEEDED
FOR LIGHTWEIGHT GARAGE
1. Center the door bracket on the previously marked
vertical centerline used for the header bracket
installation. Note correct UP placement, as stamped
inside the bracket.
Vertical
DOORS (FIBERGLASS,
Centerline
ALUMINUM, STEEL, DOORS
of Garage
WITH GLASS PANEL, ETC).
Door
(NOT PROVIDED)
2. Position the top edge of the bracket 2"-4" (5-10 cm)
below the top edge of the door, OR directly below any
structural support across the top of the door.
Figure 1
3. Mark, drill holes and install as follows, depending on
your door’s construction:
Vertical Reinforcement
Metal or light weight doors using a vertical angle iron
brace between the door panel support and the door
bracket:
Vertical Centerline
of Garage Door
UP
Vertical Reinforcement
Vertical
•
Drill 3/16" fastening holes. Secure the door bracket
using the two 1/4"-14x5/8" self-threading screws.
(Figure 2A)
Centerline
of Garage Door
Bolt
Door Bracket
Self-Threading
•
Alternately, use two 5/16" bolts, lock washers and nuts
(not provided). (Figure 2B)
5/16"-18x2"
(Not
UP
Screw 1/4"-14x5/8"
Provided)
Metal, insulated or light weight factory reinforced
doors:
Figure 2A
Door
Bracket
•
Drill 3/16" fastening holes. Secure the door bracket
using the self-threading screws (Figure 3).
Lock Washer 5/16"
Nut
5/16"-18
Wood Doors:
Figure 2B
•
Use top and bottom or side to side door bracket holes.
Drill 5/16" holes through the door and secure bracket
with 5/16"x2" carriage bolts, lock washers and nuts
(not provided). (Figure 4)
Inside Edge of
Door or
Reinforcement
Board
Bolt 5/16"-18x2"
(Not Provided)
NOTE: The 1/4"-14x5/8" self-threading screws are not
intended for use on wood doors.
Vertical
Centerline
of Garage
Door
UP
Vertical
Centerline
of Garage
Door
HARDWARE SHOWN ACTUAL SIZE
UP
Self-Threading Screw
1/4"-14x5/8"
Self-Threading
Screw
1/4"-14x5/8"
Figure 4
Figure 3
23
Download from Www.Somanuals.com. All Manuals Search And Download.
ONE-PIECE DOORS
Please read and comply with the warnings and
reinforcement instructions on the previous page. They
apply to one-piece doors also.
•
•
•
Center the door bracket on the top of the door, in line
with the header bracket as shown. Mark either the left
and right, or the top and bottom holes.
Metal Doors: Drill 3/16" pilot holes and fasten the
bracket with the 1/4"-14x5/8" self-threading screws
provided.
HARDWARE SHOWN ACTUAL SIZE
Wood Doors: Drill 5/16" holes and use 5/16"x2"
carriage bolts, lock washers and nuts (not provided)
or 5/16"x1-1/2" lag screws (not provided) depending
on your installation needs.
Self-Threading Screw
1/4"-14x5/8"
NOTE: The door bracket may be installed on the top edge
of the door if required for your installation. (Refer to the
dotted line optional placement drawing.)
Self-Threading
Screw 1/4"-14x5/8"
Header Wall
Door
Bracket
Top of Door
(Inside Garage)
Finished
Ceiling
2x4 Support
Top Edge
of Door
Header
Bracket
Optional
Placement
Door
Bracket
METAL DOOR
Optional
Placement
of Door
HORIZONTAL
AND VERTICAL
REINFORCEMENT
IS NEEDED FOR
LIGHTWEIGHT
GARAGE DOORS
(FIBERGLASS,
ALUMINUM, STEEL,
DOORS WITH GLASS
PANEL, ETC.). (NOT
PROVIDED)
Lock Washer
5/16"
Nut
Bracket
5/16"-18
Top of Door
(Inside Garage)
Door
Bracket
Vertical
Centerline of
Garage Door
Top Edge
of Door
Optional
Placement
Carriage Bolt
5/16"x2"
(Not Provided)
WOOD DOOR
For a door with no exposed framing, or for the
optional installation, use lag screws 5/16"x1-1/2"
(Not Provided) to fasten door bracket.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 1
Outer Trolley
INSTALLATION STEP 13
Inner Trolley
Connect Door Arm to Trolley
Follow instructions which apply to your door type as
illustrated below and on the following page.
Ring
Fastener
Clevis Pin
5/16"x1"
SECTIONAL DOORS ONLY
•
Make sure garage door is fully closed. Pull the
emergency release handle to disconnect the outer
trolley from the inner trolley. Slide the outer trolley
back (away from the door) about 2" (5 cm) as shown in
Figures 1, 2 and 3.
Straight
Door Arm
Emergency
Release
Handle
Door
Bracket
•
Figure 1:
Curved
– Fasten straight door arm section to outer trolley with
the 5/16"x1" clevis pin. Secure the connection with a
ring fastener.
Door Arm
Clevis Pin
5/16"x1-1/4"
Figure 2
– Fasten curved section to the door bracket in the same
way, using the 5/16"x1-1/4" clevis pin.
IMPORTANT: The groove on the straight door arm MUST
face away from the curved door arm (Figure 4).
•
Figure 2:
– Bring arm sections together. Find two pairs of holes
that line up and join sections. Select holes as far apart
as possible to increase door arm rigidity.
Lock Washers
5/16"
Nuts
5/16"-18
•
Figure 3, Hole alignment alternative:
– If holes in curved arm are above holes in straight
arm, disconnect straight arm. Cut about 6" (15 cm)
from the solid end. Reconnect to trolley with cut end
down as shown.
Bolts
5/16"-18x7/8"
– Bring arm sections together.
Door Bracket
– Find two pairs of holes that line up and join with
bolts, lock washers and nuts.
Figure 3
•
Pull the emergency release handle toward the opener at
a 45° angle so that the trolley release arm is horizontal.
Proceed to Adjustment Step 1, page 27. Trolley will
re-engage automatically when opener is operated.
Lock
Washers
5/16"
HARDWARE SHOWN ACTUAL SIZE
Nuts
5/16"-18
Ring Fastener
Nut 5/16"-18
Bolts
5/16"-18x7/8"
Cut this end
Figure 4
Clevis Pin
5/16"x1-1/4" (Door Bracket)
CORRECT
INCORRECT
Lock Washer 5/16"
Straight
Door Arm
Straight
Door Arm
Curved
Curved
Door
Arm
Hex Bolt
5/16"-18x7/8"
Clevis Pin
5/16"x1" (Trolley)
Door
Arm
(Groove
facing out)
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5
ALL ONE-PIECE DOORS
CORRECT
INCORRECT
1. Assemble the door arm, Figure 5:
IMPORTANT: The groove on the straight door arm MUST
face away from the curved door arm (Figure 5).
Straight
Door Arm
Straight
Door Arm
• Fasten the straight and curved door arm sections
together to the longest possible length (with a 2 or 3
hole overlap).
Curved
Door
Arm
Curved
Door
Arm
(Groove
facing out)
• With the door closed, connect the straight door arm
section to the door bracket with the 5/16"x1-1/4"
clevis pin.
Door
Bracket
• Secure with a ring fastener.
Ring
Fastener
2. Adjustment procedures, Figure 6:
Lock
Nuts
Washers 5/16"-18
5/16"
• On one-piece doors, before connecting the door arm
to the trolley, the travel limits must be adjusted. Limit
adjustment screws are located on the left side panel
as shown on page 27. Follow adjustment procedures
below.
Clevis Pin
5/16"x1-1/4"
Straight
Arm
• Open door adjustment: decrease UP travel limit
Bolts
5/16"-18x7/8
Curved
Door Arm
- Turn the UP limit adjustment screw
counterclockwise 4 turns.
- Manually close the door and lift the door arm to the
trolley. The arm should touch the trolley just ahead of
the door arm connector hole. Refer to the fully closed
trolley/door arm positions in the illustration. If the arm
is behind the connector hole, adjust the limit further.
One full turn equals 2" (5 cm) of trolley travel.
- Press the Door Control push button. The trolley will
travel to the fully open position.
- Manually raise the door to the open position
(parallel to the floor), and lift the door arm to the
trolley. The arm should touch the trolley just in back
of the door arm connector hole. Refer to the fully
open trolley/door arm positions in the illustration.
If the arm does not extend far enough, adjust the
limit further. One full turn equals 2" (5 cm) of trolley
travel.
3. Connect the door arm to the trolley:
• Close the door and join the curved arm to the
connector hole in the trolley with the remaining clevis
pin. It may be necessary to lift the door slightly to
make the connection.
• Closed door adjustment: decrease DOWN travel
limit
• Secure with a ring fastener.
• Run the opener through a complete travel cycle. If the
door has a slight "backward" slant in full open position
as shown in the illustration, decrease the UP limit until
the door is parallel to the floor.
- Turn the DOWN limit adjustment screw clockwise
4 complete turns.
- Press the Door Control push button. The trolley will
travel to the fully closed position.
NOTE: When setting the up limit on the following page, the
door should not have a "backward" slant when fully open
as illustrated below. A slight backward slant will cause
unnecessary bucking and/or jerking operation as the door
is being opened or closed from the fully open position.
Figure 6
Inner Trolley
- Closed Door -
Outer Trolley
Door Arm Connector Hole
Door Arm
Emergency Release Handle
Closed Door
Inner Trolley
Outer Trolley
Correct Angle
Door Arm
Connector Hole
Door with
Backward Slant (Incorrect)
Open Door
26
Download from Www.Somanuals.com. All Manuals Search And Download.
ADJUSTMENT STEP 1
Adjust the UP and DOWN Travel Limits
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
Limit adjustment settings regulate the points at which the
door will stop when moving up or down.
To operate the opener, press the Door Control push bar.
Run the opener through a complete travel cycle.
•
Incorrect adjustment of garage door travel limits
will interfere with proper operation of safety
reversal system.
•
•
Does the door open and close completely?
•
•
If one control (force or travel limits) is adjusted,
the other control may also need adjustment.
After ANY adjustments are made, the safety
reversal system MUST be tested. Door MUST
reverse on contact with 1-1/2" (3.8 cm) high object
(or 2x4 laid flat) on floor.
Does the door stay closed and not reverse
unintentionally when fully closed?
If your door passes both of these tests, no limit
adjustments are necessary unless the reversing test fails
(Adjustment Step 3, page 29).
Adjustment procedures are outlined below. Read the
procedures carefully before proceeding to Adjustment
Step 2. Use a screwdriver to make limit adjustments. Run
the opener through a complete travel cycle after each
adjustment.
NOTE: Repeated operation of the opener during
adjustment procedures may cause the motor to overheat
and shut off. Simply wait 15 minutes and try again.
To prevent damage to vehicles, be sure fully open
door provides adequate clearance.
NOTE: If anything interferes with the door’s upward
travel, it will stop. If anything interferes with the door’s
downward travel (including binding or unbalanced doors),
it will reverse.
HOW AND WHEN TO ADJUST THE LIMITS
•
If the door does not open completely but opens at
least 5 feet (1.5 m):
Limit Adjustment Screws
Left Side Panel
Increase up travel. Turn the UP limit adjustment screw
clockwise. One turn equals 2" (5 cm) of travel.
•
•
If door does not open at least 5 feet (1.5 m):
Adjust the UP (open) force as explained in Adjustment
Step 2.
If the door does not close completely:
Increase down travel. Turn the down limit adjustment
screw counterclockwise. One turn equals 2" (5 cm) of
travel.
If door still won't close completely try lengthening the
door arm (page 25) and decreasing the down limit.
ADJUSTMENT LABEL
•
•
If the opener reverses in fully closed position:
Decrease down travel. Turn the down limit adjustment
screw clockwise. One turn equals 2" (5 cm) of travel.
If the door reverses when closing and there is no
visible interference to travel cycle:
If the opener lights are flashing, the Safety Reversing
Sensors are either not installed, misaligned, or
obstructed. See Troubleshooting, page 22.
Test the door for binding: Pull the emergency release
handle. Manually open and close the door. If the
door is binding or unbalanced, call for a trained
door systems technician. If the door is balanced and
not binding, adjust the DOWN (close) force. See
Adjustment Step 2.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
ADJUSTMENT STEP 2
Adjust the Force
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
Force adjustment controls are located on the back panel
of the motor unit. Force adjustment settings regulate the
amount of power required to open and close the door.
•
•
•
•
•
Too much force on garage door will interfere with
proper operation of safety reversal system.
NEVER increase force beyond minimum amount
required to close garage door.
NEVER use force adjustments to compensate for a
binding or sticking garage door.
If one control (force or travel limits) is adjusted,
the other control may also need adjustment.
After ANY adjustments are made, the safety
reversal system MUST be tested. Door MUST
reverse on contact with 1-1/2" (3.8 cm) high object
(or 2x4 laid flat) on floor.
If the forces are set too light, door travel may be
interrupted by nuisance reversals in the down direction
and stops in the up direction. Weather conditions can
affect the door movement, so occasional adjustment may
be needed.
The maximum force adjustment range is about 3/4 of a
complete turn. Do not force controls beyond that point.
Turn force adjustment controls with a screwdriver.
NOTE: If anything interferes with the door’s upward
travel, it will stop. If anything interferes with the door’s
downward travel (including binding or unbalanced doors),
it will reverse.
HOW AND WHEN TO ADJUST THE FORCES
Force
1. Test the DOWN (close) force
Adjustment
Controls
Back Panel
•
Grasp the door bottom when the door is about
halfway through DOWN (close) travel. The door
should reverse. Reversal halfway through down
travel does not guarantee reversal on a 1-1/2"
(3.8 cm) obstruction. See Adjustment Step 3,
page 29. If the door is hard to hold or doesn't
reverse, DECREASE the DOWN (close) force by
turning the control counterclockwise. Make small
adjustments until the door reverses normally.
After each adjustment, run the opener through a
complete cycle.
•
If the door reverses during the down (close) cycle
and the opener lights aren't flashing, INCREASE
DOWN (close) force by turning the control
clockwise. Make small adjustments until the door
completes a close cycle. After each adjustment, run
the opener through a complete travel cycle. Do not
increase the force beyond the minimum amount
required to close the door.
Antenna
FORCE ADJUSTMENT LABEL
2. Test the UP (open) force
•
Grasp the door bottom when the door is about
halfway through UP (open) travel. The door should
stop. If the door is hard to hold or doesn't stop,
DECREASE UP (open) force by turning the control
counterclockwise. Make small adjustments until
the door stops easily and opens fully. After each
adjustment, run the opener through a complete
travel cycle.
Open Force
Close Force
•
If the door doesn’t open at least 5 feet (1.5 m),
INCREASE UP (open) force by turning the
control clockwise. Make small adjustments until
door opens completely. Readjust the UP limit if
necessary. After each adjustment, run the opener
through a complete travel cycle.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
ADJUSTMENT STEP 3
Test the Safety Reversal System
TEST
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
•
With the door fully open, place a 1-1/2" (3.8 cm) board
(or a 2x4 laid flat) on the floor, centered under the
garage door.
•
•
•
Safety reversal system MUST be tested every
month.
If one control (force or travel limits) is adjusted,
the other control may also need adjustment.
After ANY adjustments are made, the safety
reversal system MUST be tested. Door MUST
reverse on contact with 1-1/2" high (3.8 cm) object
(or 2x4 laid flat) on the floor.
•
Operate the door in the down direction. The door must
reverse on striking the obstruction.
ADJUST
•
If the door stops on the obstruction, it is not traveling
far enough in the down direction. Increase the DOWN
limit by turning the DOWN limit adjustment screw
counterclockwise 1/4 turn.
NOTE: On a sectional door, make sure limit
adjustments do not force the door arm beyond a
straight up and down position. See the illustration on
page 25.
•
•
Repeat the test.
When the door reverses on the 1-1/2" (3.8 cm) board,
remove the obstruction and run the opener through 3
or 4 complete travel cycles to test adjustment.
•
If the unit continues to fail the Safety Reverse Test, call
for a trained door systems technician.
IMPORTANT SAFETY CHECK:
Test the Safety Reverse System after:
•
Each adjustment of door arm length, limits, or force
controls.
•
Any repair to or adjustment of the garage door
(including springs and hardware).
1-1/2" (3.8 cm) board
(or a 2x4 laid flat)
•
•
Any repair to or buckling of the garage floor.
Any repair to or adjustment of the opener.
ADJUSTMENT STEP 4
Test The Protector System®
Without a properly installed safety reversing sensor,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
•
•
•
Press the remote control push button to open the door.
Place the opener carton in the path of the door.
Press the remote control push button to close the
door. The door will not move more than an inch
(2.5 cm), and the opener lights will flash.
The garage door opener will not close from a remote if the
indicator light in either sensor is off (alerting you to the
fact that the sensor is misaligned or obstructed).
If the opener closes the door when the safety reversing
sensor is obstructed (and the sensors are no more
than 6" (15 cm) above the floor), call for a trained door
systems technician.
Safety Reversing Sensor
Safety Reversing Sensor
29
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND
INSTRUCTIONS.
9. If one control (force or travel limits) is adjusted, the
other control may also need adjustment.
2. ALWAYS keep remote controls out of reach of
children. NEVER permit children to operate or play with
garage door control push buttons or remote controls.
3. ONLY activate garage door when it can be seen clearly,
it is properly adjusted, and there are no obstructions
to door travel.
4. ALWAYS keep garage door in sight until completely
closed. NO ONE SHOULD CROSS THE PATH OF THE
MOVING DOOR.
5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY
OPEN DOOR.
10. After ANY adjustments are made, the safety reversal
system MUST be tested.
11. Safety reversal system MUST be tested every month.
Garage door MUST reverse on contact with 1-1/2"
(3.8 cm) high object (or a 2x4 laid flat) on the floor.
Failure to adjust the garage door opener properly may
cause SEVERE INJURY or DEATH.
12. ALWAYS KEEP GARAGE DOOR PROPERLY
BALANCED (see page 3). An improperly balanced
door may NOT reverse when required and could
result in SEVERE INJURY or DEATH.
13. ALL repairs to cables, spring assemblies and other
hardware, ALL of which are under EXTREME tension,
MUST be made by a trained door systems technician.
14. ALWAYS disconnect electric power to garage door
opener BEFORE making ANY repairs or removing
covers.
6. If possible, use emergency release handle to disengage
trolley ONLY when garage door is CLOSED. Weak or
broken springs or unbalanced door could result in an
open door falling rapidly and/or unexpectedly, causing
SEVERE INJURY or DEATH.
7. NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
15. INSTRUCTIONS.
SAVE THESE
8. NEVER use handle to pull garage door open or closed.
If rope knot becomes untied, you could fall.
Using Your Garage Door Opener
Your Security✚® opener and hand-held remote control
have been factory-set to a matching code which changes
with each use, randomly accessing over 100 billion
new codes. Your opener will operate with up to eight
Security✚® remote controls and one Security✚® Keyless
Entry System. If you purchase a new remote, or if you
wish to deactivate any remote, follow the instructions in
the Programming section.
6. If obstructed while opening, the door will stop.
7. If fully open, the door will not close when the beam is
broken. The sensor has no effect in the opening cycle.
If the sensor is not installed, or is misaligned, the door
won't close from a hand-held remote. However, you can
close the door with the Door Control, the Outdoor Key
Switch, or Keyless Entry, if you activate them until down
travel is complete. If you release them too soon, the door
will reverse.
Activate your opener with any of the following:
•
•
•
The hand-held Remote Control: Hold the large push
button down until the door starts to move.
The opener lights will turn on under the following
conditions: when the opener is initially plugged in; when
power is restored after interruption; when the opener is
activated.
The wall-mounted Door Control: Hold the push button
or bar down until the door starts to move.
The Keyless Entry (See Accessories): If provided with
your garage door opener, it must be programmed
before use. See Programming.
They will turn off automatically after 4-1/2 minutes or
provide constant light when the Light feature on the
Multi-Function Door Control Panel is activated. Bulb size is
A19. Bulb power is 100 watts maximum.
Security✚® light feature: Lights will also turn on when
someone walks through the open garage door. With a
Multi-Function Door Control Panel, this feature may be
turned off as follows: With the opener lights off, press and
hold the light button for 10 seconds, until the light goes
on, then off again. To restore this feature, start with the
opener lights on, then press and hold the light button for
10 seconds until the light goes off, then on again.
When the opener is activated (with the safety reversing
sensor correctly installed and aligned)
1. If open, the door will close. If closed, it will open.
2. If closing, the door will reverse.
3. If opening, the door will stop.
4. If the door has been stopped in a partially open
position, it will close.
5. If obstructed while closing, the door will reverse. If the
obstruction interrupts the sensor beam, the opener
lights will blink for five seconds.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Wall-Mounted Door Control
To Open the Door Manually
THE MULTI-FUNCTION DOOR CONTROL
Press the lighted push button to
Push
open or close the door. Press again
to reverse the door during the
closing cycle or to stop the door
while it's opening.
Button
To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
• If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
• NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If
rope knot becomes untied, you could fall.
Lock
Button
Light
Button
Light feature
Press the Light button to turn the opener light on or off.
It will not control the opener lights when the door is in
motion. If you turn it on and then activate the opener, the
light will remain on for 4-1/2 minutes. Press again to turn
it off sooner. The 4-1/2 minute interval can be changed to
1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold
the Lock button until the light blinks (about 10 seconds).
A single blink indicates that the timer is reset to 1-1/2
minutes. Repeat the procedure and the light will blink
twice, resetting the timer to 2-1/2 minutes. Repeat again
for a 3-1/2 minute interval, etc., up to a maximum of four
blinks and 4-1/2 minutes.
DISCONNECT THE TROLLEY:
The door should be fully
Trolley
closed if possible. Pull
down on the emergency
release handle (so that
the trolley release arm
snaps into a vertical
position) and lift the
door manually.
Trolley Release
Arm (in Manual
Disconnect
Lock feature
Designed to prevent operation of the door from
hand-held remote controls. However, the door will open
and close from the Door Control, the Outdoor Keylock and
the Keyless Entry Accessories.
Position)
NO
TICE
The lockout feature
prevents the trolley from
reconnecting automatically,
and the door can be raised
Lockout position
(Manual Disconnect)
To activate, press and hold the Lock button for 2 seconds.
The push button light will flash as long as the Lock feature
is on.
and lowered manually as often as necessary.
To turn off, press and hold the Lock button again for
2 seconds. The push button light will stop flashing. The
Lock feature will also turn off whenever the “learn” button
on the motor unit panel is activated.
TO RE-CONNECT THE TROLLEY:
Pull the emergency
release handle
Trolley
toward the opener
at a 45° degree
angle so that the
trolley release arm
Emergency
Trolley
Release Arm
TICE
NO
is horizontal. The
Release Handle
trolley will reconnect
on the next UP or
(Pull at 45° angle)
DOWN operation,
either manually or by using the
door control or remote.
To Reconnect
31
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE OF YOUR OPENER
LIMIT AND FORCE ADJUSTMENTS:
THE REMOTE CONTROL BATTERY
Weather conditions may cause
some minor changes in door
operation requiring some
re-adjustments, particularly
during the first year of operation.
FORCE CONTROLS
To prevent possible SERIOUS INJURY or DEATH:
•
•
NEVER allow small children near batteries.
If battery is swallowed, immediately notify doctor.
Pages 27 and 28 refer to the
limit and force adjustments. Only a
screwdriver is required. Follow the
instructions carefully.
LIMIT CONTROLS
To reduce risk of fire, explosion or chemical burn:
•
•
Replace ONLY with 3V2032 coin batteries.
DO NOT recharge, disassemble, heat above 100° C
(212° F) or incinerate.
Repeat the safety reverse test
(Adjustment Step 3, page 29) after
any adjustment of limits or force.
The lithium battery should
produce power for up to
5 years.
Battery
positive
To replace battery, use the
visor clip or screwdriver
blade to pry open the case
as shown. Insert battery
positive side up (+).
side up (+)
MAINTENANCE SCHEDULE
Every Month
•
•
•
Manually operate door. If it is unbalanced or binding,
call a trained door systems technician.
Dispose of old battery
properly. Replace the
battery with only 3V2032
coin cell batteries.
Check to be sure door opens & closes fully. Adjust
limits and/or force if necessary. (See pages 27 and 28)
Repeat the safety reverse test. Make any necessary
adjustments. (See Adjustment Step 3)
NOTICE: To comply with FCC and or Industry Canada (IC) rules,
adjustment or modifications of this receiver and/or transmitter are
prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE.
Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Every Year
•
Oil door rollers, bearings and hinges. The opener does
not require additional lubrication. Do not grease the
door tracks.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
HAVING A PROBLEM?
1. My door will not close and the light bulbs blink on
my motor unit: The safety reversing sensor must be
connected and aligned correctly before the garage door
opener will move in the down direction.
Bell Wire
• Verify the safety reversing sensors are properly
installed, aligned and free of any obstructions. Refer
to Installation Step 4: Install The Protector System .
®
G
KG
• Check diagnostic LED for flashes on the motor unit
then refer to the Diagnostic Chart on the following
page.
“Learn”
Button
LED or
Diagnostic
LED
2. My remotes will not activate the door:
Safety Reversing Sensor
• Verify your Premium door control is not blinking.
If it is blinking, deactivate the Lock Mode following
the instructions for Using the Multi-Function Door
Control.
• Reprogram remotes following the programming
instructions. Refer to Programming.
Receiving Eye Safety
Reversing Sensor
(Green Indicator Light)
Sending Eye Safety
Reversing Sensor
(Amber Indicator Light)
• If remote will still not activate your door, check
diagnostic LED for flashes on motor unit then refer
to Diagnostic Chart on the following page.
3. My door reverses for no apparent reason:
Repeat safety reverse test after adjustments to force or
travel limits. The need for occasional adjustment for the
force and limit settings is normal. Weather conditions
in particular can affect door travel.
• Manually check door for balance or any binding
problems.
• Refer to Adjustment Step 2, Adjust the Force.
4. My door reverses for no apparent reason after fully
closing and touching the floor: Repeat safety reverse
test after adjustments to force or travel limits. The
need for occasional adjustment for the force and limit
settings is normal. Weather conditions in particular can
affect door travel.
• Refer to Adjustment Step 1, Adjust the UP and
DOWN Travel Limits. Decrease down travel by
turning down limit adjustment screw clockwise.
5. My lights will not turn off when door is open:
• The garage door opener is equipped with a security
light feature. This feature activates the light on when
the safety sensor beam has been obstructed. Refer
to Operation section; Using the Wall Mounted Door
Control, Light Feature.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Installed
Safety Reversing
Sensor
Diagnostics
Located On
Motor Unit
KG
Your garage door opener is programmed with
self-diagnostic capabilities. The “Learn” button/diagnostic
LED will flash a number of times then pause signifying
it has found a potential issue. Consult Diagnostic Chart
below.
LED or
Diagnostic
LED
“Learn”
Button
Safety Reversing Sensor
Diagnostic Chart
Symptom: One or both of the indicator lights on the safety reversing sensors
do not glow steady.
1 FLASH
Safety reversing sensors
wire open (broken or
disconnected).
• Inspect sensor wires for a short (staple in wire), correct wiring polarity
(black/white wires reversed), broken or disconnected wires, replace/attach
as needed.
OR
• Disconnect all wires from back of motor unit.
• Remove sensors from brackets and shorten sensor wires to 1-2 ft. (30-60 cm)
from back each of sensor.
2 FLASHES
Safety reversing sensors
wire shorted or black/white
wire reversed.
• Reattach sending eye to motor unit using shortened wires. If sending eye
indicator light glows steadily, attach the receiving eye.
• Align sensors, if the indicator lights glow replace the wires for the sensors. If
the sensor indicator lights do not light, replace the safety sensors.
3 FLASHES
Symptom: LED is not lit on door control.
• Inspect door control/wires for a short (staple in wire), replace as needed.
Door control or wire shorted.
• Disconnect wires at door control, touch wires together. If motor unit activates,
replace door control.
• If motor unit does not activate, disconnect door control wires from motor unit.
Momentarily short across red and white terminals with jumper wire. If motor
unit activates, replace door control wires.
Symptom: Sending indicator light glows steadily, receiving indicator light is
dim or flashing.
4 FLASHES
Safety reversing sensors
slightly misaligned
(dim or flashing LED).
• Realign receiving eye sensor, clean lens and secure brackets.
• Verify door track is firmly secured to wall and does not move.
Symptom: Motor has overheated; the motor unit does not operate;
RPM Sensor = Short travel 6-8" (15-20 cm).
5 FLASHES
Motor overheated or possible
RPM sensor failure. Unplug
to reset.
• Unplug unit to reset. Try to operate motor unit, check diagnostic code.
• If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace
RPM sensor.
• If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and
retry. If motor unit still will not operate replace logic board.
6 FLASHES
Symptom: Motor unit doesn’t operate.
• Replace logic board because motor rarely fails.
Motor Circuit Failure.
Replace Receiver Logic
Board.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING
®
NOTICE: If this Security✚ garage door opener is operated with a non-rolling code transmitter, the technical measure
in the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The
owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code
transmitter to circumvent that technical measure.
Your garage door opener has already been programmed at the factory to operate with your hand-held remote control.
The door will open and close when you press the large push button.
Below are instructions for programming your opener to operate with additional Security✚® remote controls.
To Add or Reprogram a Hand-held Remote Control
USING THE “LEARN” BUTTON
USING THE MULTI-FUNCTION DOOR CONTROL
9
1
9
1
7
3
7
3
5
5
K
LOCK
LIGHT
1. Press and hold the button
on the hand-held remote*
that you wish to operate your
garage door.
1. Press and release the “learn”
button on the motor unit. The
learn indicator light will glow
steadily for 30 seconds.
2. While holding the remote
button, press and hold the
2. Within 30 seconds, press and
hold the button on the hand-
held remote* that you wish to
operate your garage door.
LIGHT button on the
Multi-Function Door Control.
LOCK
LIGHT
3. Continue holding both buttons
while you press the push bar
on the Multi-Function Door
Control (all three buttons are
3. Release the button when the
motor unit lights blink. It
has learned the code. If light
bulbs are not installed, two
clicks will be heard.
LOCK
LIGHT
held).
4. Release buttons when the
motor unit lights blink. It has
learned the code. If light bulbs
are not installed, two clicks will
be heard.
To Erase All Codes From Motor
*3-Button Remotes (315 MHz)
Unit Memory
If provided with your garage door opener, the
large button is factory
programmed to operate it.
To deactivate any unwanted remote, first erase all
codes:
Additional buttons on any
Press and hold the “learn”
button on motor unit until the
learn indicator light goes out
(approximately 6 seconds). All
previous codes are now erased.
Reprogram each remote or keyless
entry you wish to use.
®
Security✚ 3-Button remote
or mini-remote can be
programmed to operate
®
other Security✚ garage door openers.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
To Add, Reprogram or Change a Keyless Entry PIN
NOTE: Your new Keyless Entry must be programmed to operate your garage door opener.
USING THE “LEARN” BUTTON
USING THE MULTI-FUNCTION DOOR CONTROL
LOCK
LIGHT
NOTE: This method requires two people if the Keyless
Entry is already mounted outside the garage.
1. Press and release the “learn”
button on motor unit. The learn
indicator light will glow steadily
for 30 seconds.
1. Enter a four digit personal
identification number (PIN) of
your choice on the keypad. Then
press and hold ENTER.
2. Within 30 seconds, enter a four
digit personal identification
number (PIN) of your choice on
the keypad. Then press and hold
the ENTER button.
2. While holding the ENTER button,
press and hold the LIGHT button
on the Multi-Function Door
LOCK
LIGHT
Control.
3. Release the button when the
motor unit lights blink. It has
learned the code. If light bulbs
are not installed, two clicks will
be heard.
3. Continue holding the ENTER and
LIGHT buttons while you press
the push bar on the
Multi-Function Door Control
(all three buttons are held).
LOCK
T
To change an existing, known PIN
If the existing PIN is known, it may be changed by one
person without using a ladder.
1. Press the four buttons for the present PIN, then press
and hold the # button.
4. Release buttons when the motor
unit lights blink. It has learned
the code. If light bulbs are not
installed, two clicks will be heard.
The opener light will blink twice. Release the # button.
2. Press the new 4-digit PIN you have chosen, then
press ENTER.
The motor unit lights will blink once when the PIN has been
learned.
Test by pressing the new PIN, then press ENTER. The door
should move.
2. Press the temporary 4-digit PIN you have chosen, then
press ENTER.
The opener light will blink four times.
3. To set the number of hours this temporary PIN will
work, press the number of hours (up to 255), then
press ✽.
OR
To set a temporary PIN
3. To set the number of times this temporary PIN will
work, press the number of times (up to 255), then
press #.
The opener light will blink once when the temporary PIN
has been learned.
Test by pressing the four buttons for the temporary
PIN, then press ENTER. The door should move. If the
temporary PIN was set to a certain number of openings,
remember that the test has used up one opening. To clear
the temporary password, repeat steps 1-3, setting the
number of hours or times to 0 in step 3.
You may authorize access by visitors or service people with
a temporary 4-digit PIN. After a programmed number of
hours or number of accesses, this temporary PIN expires
and will no longer open the door. It can be used to close
the door even after it has expired. To set a temporary PIN:
1. Press the four buttons for your personal entry PIN
(not the last temporary PIN), then press and hold the ✽
button.
The opener light will blink three times. Release the
button.
One Button Close: Opener can be closed by pressing only the ENTER button if the one button close feature has been
activated. This feature has been activated at the factory. To activate or deactivate this feature press and hold buttons 1
and 9 for 10 seconds. The keypad will blink twice when the one button close is active. The keypad will blink four times
when one button close is deactivated.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
REPAIR PARTS
Rail Assembly Parts
1
8
2
7
6
KEY PART
NO. NO.
DESCRIPTION
5
1
2
81C275
Rack
41A6263
Hardware bag (includes
sprocket coupling)
4
3
3
4
5
12B890
12B900
41A6264
Left rail bracket
Right rail bracket
Screw drive rail assembly
Complete 7' (2.1 m)
6
7
8
12B889
Rail support brace
Complete trolley assembly
Drive sprocket kit
NOT SHOWN
41A6262
41A4836
Installation Parts
4
28A143
Wire clips
1
LOCK
LIGHT
2
KEY PART
NO. NO.
DESCRIPTION
3
1
2
3
4
41A5273-14 Multi-function door control
950D
1-Button remote control
3V 2032 Lithium battery
Visor clip
Y
L
ON
CEILING MOUNT
UP
10A20
6
29B137
41A2828
5
7
5
Emergency release rope & handle assy.
NO
TICE
6
7
8
9
41B4494-1 2-Conductor bell wire: white & white/red
10
11
41A4353
41A5047
41A5034
Header bracket w/clevis pin & fastener
Door bracket w/clevis pin & fastener
Safety sensor kit: receiving and sending eyes
with 3' (.9 m) 2-conductor bell wire attached
9
10 178B34
11 12B776
12 178B35
Straight door arm section
Hanging bracket
8
12
Curved door arm section
13
13 41A5266-1 Safety sensor bracket
NOT SHOWN
41A4675-7 Installation hardware bag (see page 7)
114A4320
Owner’s manual
114A4320SP Owner’s manual - Spanish
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Motor Unit Assembly Parts
13
9a
10
9
1
2
14
3
6a
12
4
5
8
6
7
11
14
KEY PART
NO. NO.
KEY PART
NO. NO.
DESCRIPTION
DESCRIPTION
1
2
3
4
5
6
31C568
Drive shaft cover
Line cord
8
41A4837-1
41A6635
41A6634
Worm gear and retainer
Low voltage wire harness
High voltage wire harness
41B4245
30B620
9
Capacitor – 1/2
9a
10
11
12
13
14
41A3150
41D4671
41A6241
Terminal block w/screws
Limit switch assembly
Motor drive assembly
Drive belt
41AS050R2M Receiver logic board
41A5525-53 Cover
41C22-1
175B88
108D79
Drive coupling hub
Light socket
6a 20B21-1
41C4672
7
Screw drive RPM kit
Light lens
38
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
956D
3-Button Mini-Remote Control with
SECURITY✚®
3-Button SECURITY✚® Remote
Control
953D
:
:
With key ring and fastening strip.
Includes visor clip.
935CB
1702LMC
Outside Quick Release:
Motion Detecting Control Panel:
Required for a garage with NO access
door.
Multi-function door control with
motion sensor that automatically
turns opener lights on for 5 minutes
when it detects a person entering
the garage. Sensor can be easily
deactivated when desired.
LOCK
LIGHT
CLLAD
Remote Light Control
:
Enables homeowner to turn on a lamp,
television or other appliance from
their car with their garage door opener
remote or from anywhere in their
home with an additional Chamberlain
Security✚® remote.
SECURITY✚® Keyless Entry
:
940D
Enables homeowner to operate garage
door opener from outside by entering
a password on a specially designed
keyboard. Also can add a temporary
password for visitors or service
persons. This temporary password
can be limited to a programmable
number of hours or entries.
41A5281
Extension Brackets:
(Optional) For safety reversing sensor
installation onto the wall or floor.
CLDM1
7806CB
Garage Door Monitor:
To order call: 1-800-528-9131
Monitors the status of your garage
door from inside your home.
942FP-10
Fingerprint Keyless Entry
:
8 Foot (2.4 m) Rail Extension Kit:
The system uses biometric technology
that enables an authorized user to gain
access by scanning their fingerprint.
The sensor strip on the unit makes a
numeric template of the fingerprint
that is unique to that user. The
unit’s memory can store up to ten
fingerprints.
To allow an 8 foot (2.4 m) door to
open fully.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAMBERLAIN® SERVICE
IS ON CALL
HOW TO ORDER
REPAIR PARTS
Selling prices will be furnished on request or parts
will be shipped at prevailing prices and you will be
billed accordingly.
OUR LARGE SERVICE ORGANIZATION
SPANS AMERICA
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE
THE FOLLOWING INFORMATION:
INSTALLATION AND SERVICE INFORMATION
IS AS NEAR AS YOUR TELEPHONE.
SIMPLY DIAL OUR TOLL FREE NUMBER:
• PART NUMBER
• PART NAME
• MODEL NUMBER
1-800-528-9131
ADDRESS ORDERS TO:
THE CHAMBERLAIN GROUP, INC.
Technical Support Group
6050 S. Country Club Road
Tucson, Arizona 85706
For professional installation, parts and service,
contact your local CHAMBERLAIN dealer. Look for
him in the Yellow Pages, or call our Service number
for a list of dealers in your area.
SERVICE INFORMATION TOLL FREE NUMBER:
1-800-528-9131
CHAMBERLAIN® ONE YEAR LIMITED WARRANTY
6 YEAR MOTOR LIMITED WARRANTY
The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is
originally installed, that it is free from defect in materials and/or workmanship for a period of one year from the date of purchase [and
that the motor is free from defect in materials and/or workmanship for a period of 6 years from the date of purchase]. The proper
operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and
testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-9131,
toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You
will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase
receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are
confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you
and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE ONE YEAR LIMITED
WARRANTY PERIOD SET FORTH ABOVE [EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE MOTOR, WHICH ARE
LIMITED IN DURATION TO THE 6 YEAR LIMITED WARRANTY PERIOD FOR THE MOTOR], AND NO IMPLIED WARRANTIES WILL
EXIST OR APPLY AFTER SUCH PERIOD. Some states do not allow limitations on how long an implied warranty lasts, so the
above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED
BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE
REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR
CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS
INSTALLED FOR NON-RESIDENTIAL USE.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE
DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES.
THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT
DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING
IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH
OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED
HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS
PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or
exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
© 2011, The Chamberlain Group, Inc.
114A4320
All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
|