Chamberlain Garage Door Opener 1270LMC User Manual

®
TM  
Garage Door Opener  
Model 1270LMC  
- 1/2 HP -  
For Residential Use Only  
Owner's Manual  
Please read this manual and the enclosed safety materials carefully!  
Fasten the manual near the garage door after installation.  
The door WILL NOT CLOSE unless the Protector System® is connected and  
properly aligned  
Periodic checks and adjustment of the opener are required to ensure safe  
operation.  
The model number label is located under the light lens on the left side of your  
opener.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
You'll Need Tools  
During assembly, installation and adjustment of the opener, instructions will call for hand tools shown below.  
Pencil  
Carpenter's  
2
1
Level  
Hack Saw  
Tape Measure  
Wire Cutters  
Drill  
Claw Hammer  
3/16", 5/16" and  
5/32" Drill Bits  
Pliers  
1/2" and 7/16" Sockets  
and Wrench  
Stepladder  
Screwdriver  
Adjustable End Wrench  
CAUTION  
WARNING  
An unbalanced garage door might not reverse  
when required and someone under the door  
could be seriously injured or killed.  
If your garage door binds, sticks or is out of  
balance, call for professional garage door  
service. Garage doors, door springs, cables,  
pulleys, brackets and their hardware, are  
under extreme tension and can cause serious  
injury or death. Do not try to loosen, move or  
adjust them yourself!  
To avoid damage to the garage door and  
opener, disable locks before installing and  
operating the opener. Use a wood screw or nail  
to hold locks in the "open" (unlocked) position.  
Operation at other than 120V 60 Hz will cause  
opener malfunction and damage.  
Before you begin, complete the following test to  
make sure your door is balanced, and is not  
sticking or binding:  
Ropes left on a garage door could cause  
someone to become entangled and killed.  
Remove all ropes connected to the door before  
installing and operating the opener.  
• Lift the door about halfway as shown. Release the  
door. It should stay in place, supported entirely by  
its springs.  
Identify the type and height of your door and any  
special conditions that exist and any additional  
materials that may be required by referring to page 4.  
• Raise and lower the door to see if there is any  
binding or sticking.  
ONE-PIECE DOOR  
SECTIONAL DOOR  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before you begin, survey your garage area to see whether any of the conditions below apply to your installation.  
Sectional Door Installation  
FINISHED CEILING  
Support bracket &  
fastening hardware  
is required.  
Horizontal and vertical reinforcement  
See page 13.  
is needed for lightweight garage doors  
Slack in belt tension  
is normal when  
garage door is closed.  
(fiberglass, steel, aluminum,  
door with glass panels, etc.).  
See page 20 for details.  
Header Wall  
Extension Spring  
OR  
Torsion Spring  
Access Door  
Door Center  
Safety  
Reversing  
Sensor  
Floor must be level  
across width of door  
Model 1702LMC Outside Quick Release  
is required if there is no access door.  
Safety  
Reversing Sensor  
One-Piece Door Installation  
One-Piece Door without Track  
FINISHED CEILING  
Support bracket  
& fastening hardware  
may be required.  
Slack in belt tension  
is normal when  
See page 13.  
garage door is closed  
Header  
Wall  
One-Piece Door with Track  
Slack in belt tension  
is normal when  
garage door is closed.  
Access Door  
Access  
Door  
Safety  
Reversing  
Sensor  
Gap between floor  
and bottom of door  
must not exceed 1/4".  
Safety  
Reversing  
Sensor  
Safety  
Reversing Sensor  
Floor must be level  
across width of door  
Safety  
Reversing Sensor  
You may find it helpful to refer back to this page as  
you proceed with the installation of your opener.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Opener Carton Inventory  
Your garage door opener is packaged in two cartons which contain all parts illustrated below. If anything is  
missing, carefully check the packing material. Parts may be "stuck" in the foam. Hardware for installation is  
also listed below.  
LOCK  
LIGHT  
Remote Control  
Transmitter Visor Clip  
Belt Cap Retainer  
Single-Function  
Remote Control  
Transmitter (1)  
Multi-Function  
Door Control Panel  
Styrofoam  
Belt  
Light Lens (2)  
Door Bracket Plate  
2-Conductor Bell Wire  
White & White/Red  
Curved Door  
Arm Section  
One-Piece  
T-rail  
CEILING MOUNT ONLY  
UP  
Door Bracket  
Header Bracket  
2-Conductor Bell Wire  
with Connector (2 rolls)  
White & White/Black  
Trolley  
Safety Reversing Sensor (2)  
(1) Sending Eye  
Belt  
Pulley Bracket  
(1) Receiving Eye  
Straight Door  
Arm Section  
Safety Labels  
and  
Literature  
Safety Reversing Sensor  
Mounting Bracket  
With Slot (2)  
Safety Reversing Sensor  
Mounting Bracket  
With Square Holes (2)  
"C" Wrap (2)  
Safety Reversing Sensor  
Installation Hardware  
Installation Hardware  
Hex Screw 5/16"-18x7/8" (4)  
Hex Screw #8x3/8" (2)  
Screw 6ABx1" (2)  
Lag Screw 1/4"x1-1/2" (4)  
Carriage Bolt 1/4"-20x1/2" (4)  
Lock Nut 1/4"-20 (4)  
Handle  
Lag Screw 5/16"-18x1-7/8" (4)  
Carriage Bolt 5/16"-18x2-1/2" (2)  
Clevis Pin 5/16"x2-3/4" (1)  
Clevis Pin 5/16"x1" (2)  
Insulated Staples (10)  
Ring Fastener (3)  
Rail Grease  
Wing Nut (2)  
Hex Screw 1/4"-20x1-1/2" (2)  
Screw #10-32x3/8" (4)  
Lock Nut #10-32 (4)  
Rope  
Nut 5/16"-18 (6)  
Dry Wall Anchors (2)  
Lock Washer 5/16" (6)  
Insulated Staples (20)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Assembly Section: Pages 6 – 7  
Assembly Step 1  
Attach the T-rail to the Opener  
CAUTION  
To fasten rail, use only those screws mounted  
in top of the opener. Failure to do so will cause  
serious damage to the opener.  
Washered Screw  
5/16"-18x1/2"  
• Remove the two washered screws mounted in top  
of opener.  
Styrofoam  
• Align T-rail and styrofoam over opener sprocket.  
• Cut tape from T-rail, belt and styrofoam.  
REMOVE STYROFOAM.  
Belt  
• Insert both washered screws through the T-rail into  
the opener. Tighten both screws securely.  
USE ONLY THIS  
TYPE AND SIZE  
SCREW  
T-rail  
Hole  
Remember to use only these screws! Any other  
screws will cause serious damage to the opener.  
Washered Screw  
5/16"-18x1/2"  
• Position belt over the opener sprocket.  
Opener  
Sprocket  
T-rail  
Hole  
Belt  
T-rail  
Hole  
Assembly Step 2  
Set the Belt Tension  
Trolley  
• By hand, thread the spring trolley nut on the  
threaded shaft until it is finger tight against the  
trolley. Do not overtighten.  
Trolley  
Threaded  
Shaft  
Spring  
Trolley Nut  
• Insert a small screwdriver tip into one of the insert  
slots of the nut ring, and hold firmly.  
• Using an open end wrench at the square end,  
slightly rotate the assembly clockwise until the nut  
ring is released against the trolley, providing  
tension for the best operation of the opener.  
Trolley  
Threaded Shaft  
Nut  
Ring  
Nut Ring  
Insert Slot  
Open End  
Wrench  
Screw-  
driver  
Trolley  
Square End  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Assembly Step 3  
Attach the Belt Cap Retainer  
WARNING  
Serious injury can result if fingers become  
entangled in moving opener sprocket. Attach  
sprocket cover securely. Never operate opener  
while your hand is near the opener sprocket.  
• Position the belt cap retainer over the  
opener sprocket so the two holes in cap align  
with the two holes in mounting plate. Attach  
with #8x3/8" hex screws provided.  
Hex Screws  
#8x3/8"  
Belt Cap  
Retainer  
Opener Sprocket  
Mounting Plate  
Hardware Shown Actual Size  
Belt  
Hex Screw  
#8x3/8"  
You have now finished assembling your garage door opener. Please read the following  
warnings before proceeding to the installation section:  
IMPORTANT INSTALLATION INSTRUCTIONS  
WARNING  
WARNING  
To reduce the risk of severe injury or death to persons:  
1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.  
2. Install only on a properly balanced and lubricated garage door. An improperly balanced door  
could result in severe injury or death. Repairs to cables, spring assemblies and other hardware  
must be made by a professional service person before installing opener.  
3. Disable all locks and remove all ropes connected to the garage door before installing the opener.  
Ropes connected to a garage door can cause entanglement and death.  
4. If possible, install door opener 7 feet or more above floor with the manual release handle  
mounted 6 feet above the floor.  
5. Do not connect the opener to power source until instructed to do so.  
6. Locate the Door Control within sight of the door at a minimum height of 5 feet where small  
children cannot reach and away from all moving parts of the door.  
7. Install the User Safety Instruction Label on the wall adjacent to the control button and the  
Maintenance Instruction Label in a prominent location on the inside of the garage door.  
8. Upon completion of the installation, the door must reverse when it comes in contact with a  
2x4 laid flat on the floor.  
9. Do not wear watches, rings or loose clothing while installing or servicing an opener. Jewelry or  
loose clothing can be caught in the mechanism of the garage door or the opener.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Section: Pages 8 – 23  
Installation Step 1  
Determine Header Bracket Location  
WARNING  
If the header bracket is not rigidly fastened to  
a structural support on the header wall or  
ceiling, the safety reverse system may not  
work properly (see page 26). The door might  
not reverse when required, and could cause  
serious injury or death.  
Installation procedures vary according to garage  
door types. Follow the instructions which apply to  
your door.  
The garage door springs, cables, pulleys,  
brackets and their hardware are under extreme  
tension. Do not attempt to loosen, move or  
adjust them yourself. Serious personal injury  
or death could result. Call for garage door  
service.  
SECTIONAL Doors and  
ONE-PIECE Door With Track  
Finished  
Ceiling  
Vertical  
Guideline  
Header  
Wall  
2x4  
Structural  
Supports  
• Close the door and mark the inside  
vertical centerline of the garage door.  
• Extend the line onto the header wall  
above the door.  
Remember, you can fasten the  
header bracket within 2 feet to the  
left or right of the door center only if  
a torsion spring or center bearing  
plate is in the way; or you can attach  
it to the ceiling (refer to page 10)  
when clearance is minimal. (It may  
be mounted on the wall upside down  
if necessary, to gain approximately  
1/2".)  
Vertical  
Guideline  
If you need to install the header bracket  
on a 2x4 (on wall or ceiling), use lag  
screws (not supplied) to securely fasten  
the 2x4 to structural supports.  
Ceiling  
Header  
Wall  
2"  
Track  
Header  
Wall  
2"  
• Open your door to the highest  
point of travel as shown. Draw  
an intersecting horizontal line  
on the header wall 2" above  
the high point. This height will  
provide travel clearance for the  
top edge of the door.  
Track  
Highest Point  
of Travel  
Highest Point  
of Travel  
Door  
Door  
Sectional door with  
curved track  
One-piece door with  
horizontal track  
Proceed to Step 2, page 10.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ONE-PIECE Door Without Track  
Read the Safety Instructions on page 8. They also apply to doors without tracks.  
Unfinished  
Ceiling  
Header Wall  
Vertical  
Centerline  
2x4  
• Close the door and mark the  
Structural  
Supports  
inside vertical centerline of  
your garage door. Extend the  
line onto the header wall  
above door.  
If headroom clearance is  
minimal, you can install the  
header bracket on the ceiling.  
See page 10.  
2x4  
Vertical  
Centerline of  
Garage Door  
OPTIONAL CEILING MOUNT  
If you need to install the  
header bracket on a 2x4 (on  
wall or ceiling), use lag screws  
(not supplied) to securely  
fasten the 2x4 to structural  
supports as shown.  
Header Wall  
Highest Point  
Highest Point  
of Travel  
Header  
Wall  
of Travel  
Door  
Door  
Jamb  
Hardware  
Pivot  
One-piece door without track  
jamb hardware  
One-piece door without track  
pivot hardware  
• Open your door to the highest point of travel as  
shown. Measure the distance from the top of the  
door to the floor. Subtract the actual height of the  
door. Add 8" to the remainder. (See Example).  
EXAMPLE  
Distance from top of door  
(at highest point of travel) to floor...........................92"  
Actual height of door .............................................-88"  
Remainder................................................................4"  
Add.........................................................................+8"  
Bracket height on header wall..............................=12"  
(Measure UP from top of CLOSED door.)  
• Close the door and draw an intersecting horizontal  
line on the header wall at the determined height.  
If the total number of inches exceeds the height  
available in your garage, use the maximum  
height possible, or refer to page 10 for ceiling  
installation.  
Proceed to Step 2, page 10.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
You can attach the header bracket either to the  
wall above the garage door, or to the ceiling.  
Follow the instructions which will work best for  
your particular requirements.  
Installation Step 2  
Install the Header Bracket  
Fasten the Header Bracket to the Wall  
• Center the bracket on the vertical guideline with  
the bottom edge of the bracket on the horizontal  
line as shown (with the arrow pointing toward the  
ceiling).  
• Mark either set of bracket holes (do not use the  
holes designated for ceiling mount). Drill 3/16" pilot  
holes and fasten the bracket securely to a structural  
support with the hardware provided.  
Wall  
Mounting Holes  
Vertical  
Center  
Header  
Wall  
Line  
Lag Screws  
CEILING MOUNT ONLY  
CEILING OUNT ONLY  
UP  
5/16"x18x1-7/8"  
Header  
Bracket  
UP  
2x4  
Structural  
Support  
Door  
Spring  
The nail hole is for positioning  
only. You must use lag screws to  
mount the header bracket.  
Optional  
Wall Mounting  
Holes  
Garage  
Door  
Hardware Shown Actual Size  
Highest  
Point of Travel  
(of Garage Door)  
Vertical  
Center  
Line  
Lag Screw  
5/16"-18x1-7/8"  
Fasten the Header Bracket to the Ceiling  
• Extend the vertical guideline onto the ceiling as  
shown.  
Finished  
Ceiling  
• Center the bracket on the vertical mark, no more  
than 6" from the wall. Make sure the arrow is  
pointing toward the wall. The bracket can be  
mounted flush against the ceiling when clearance  
is minimal.  
Vertical  
Center Line  
Header  
Bracket  
• Mark holes designated for ceiling mount only. Drill  
3/16" pilot holes and fasten bracket securely to a  
structural support with the hardware provided.  
U P  
6" Maximum  
Door  
Spring  
Lag Screws  
5/16"x18x1-7/8"  
Ceiling Mounting Holes  
CEILING MOUNT ONLY  
Header  
Wall  
UP  
Vertical  
Center Line  
Garage  
Door  
The nail hole is for positioning only.  
You must use lag screws to mount  
the header bracket.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 3  
Attach the T-rail to the Header Bracket  
• Position the opener on the garage floor below the  
header bracket. Use packing material as a  
protective base.  
Header Wall  
Header  
Bracket  
If the door spring is in the way you'll need help.  
Have someone hold the opener securely on a  
temporary support to allow the T-rail to clear the  
spring.  
Belt Pulley  
Bracket  
• Position the belt pulley bracket against the header  
bracket.  
• Align the bracket holes and join with a clevis pin as  
shown.  
• Insert a ring fastener to secure.  
Ring Fastener  
T-rail  
Header Bracket  
Clevis Pin  
5/16"x2-3/4 "  
Belt Pulley  
Bracket  
T-rail  
Garage  
Door  
Temporary  
Support  
Hardware Shown Actual Size  
Clevis Pin  
5/16"x2-3/4"  
Ring Fastener  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 4  
Position the Opener  
CAUTION  
To prevent damage to steel, aluminum,  
fiberglass or glass panel doors, do not rest the  
opener on the door without using a 2x4.  
Follow instructions which apply to your door type  
as illustrated.  
SECTIONAL Door & ONE-PIECE Door with Track  
A 2x4 laid flat is convenient for setting an ideal  
door-to-T-rail distance.  
• Raise the opener onto a stepladder.  
2x4  
Laid Flat  
T-rail  
You will need help at this point if the ladder is  
not tall enough.  
• Open the door all the way and place a 2x4 laid flat  
on the top section beneath the T-rail.  
Door  
If the top panel hits the trolley when you raise  
the door, pull down on the trolley release arm  
to disconnect inner and outer sections. The  
trolley can remain disconnected until Step 12  
is completed.  
Stepladder  
Trolley  
Release Arm  
Trolley  
ONE-PIECE Door without Track  
Header  
Bracket  
• With the door fully open and parallel to the floor,  
measure the distance from the floor to the top of  
the door.  
Top of Opener  
Top of Door  
• Using a stepladder as a support, raise the opener  
to the same distance as the door from the floor (it  
will be at a slight angle as shown).  
• The top of the door should be level with the top of  
the opener. Do not position the opener more than  
2" above this point.  
Stepladder  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 5  
Hang the Opener  
WARNING  
The opener could fall and injure someone if it  
is not properly secured. Fasten the opener  
securely to structural supports of the garage.  
Two representative installations are shown.  
Yours may be different. Hanging brackets should  
be angled, Figure 1, to provide rigid support. On  
finished ceilings, Figure 2, attach a sturdy metal  
bracket to structural supports before installing the  
opener. The bracket and fastening hardware are not  
supplied.  
Figure 1  
Structural  
Supports  
Measure the distance from each side of the opener  
to the structural support.  
Lag Screws  
5/16"x1-7/8"  
• Cut both pieces of the hanging bracket to required  
lengths.  
Measure  
Distance  
Drill 3/16" pilot holes in the structural supports.  
• Attach one end of each bracket to a support with  
5/16"x1-7/8" lag screws.  
5/16"-18x7/8"  
Hex Screws  
5/16" Lock Washers  
5/16"-18 Nuts  
• Fasten the opener to the hanging brackets with  
5/16"-18x7/8" hex screws, lock washers and nuts.  
• Check to make sure the T-rail is centered over the  
door (or in line with the header bracket if the  
bracket is not centered above the door).  
• Remove the 2x4. Operate the door manually. If the  
door hits the rail, raise the header bracket.  
Figure 2  
— FINISHED CEILING —  
Bracket  
(Not Supplied)  
Hidden  
Support  
Grease the top and underside  
of the rail surface where  
the trolley slides with  
rail grease.  
Lag Screws  
5/16"x1-7/8"  
(Not Supplied)  
5/16"-18x7/8" Screw  
5/16" Lock Washer  
5/16"-18 Nut  
5/16"-18x7/8" Screw  
5/16" Lock Washer  
5/16"-18 Nut  
Hardware Shown Actual Size  
Lag Screw  
5/16"-18x1-7/8"  
Hex Screw  
5/16"-18x7/8"  
Lock Washer 5/16"  
Nut 5/16"-18  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 6  
WARNING  
Install the Multi-Function  
Door Control Panel  
Children operating or playing with a garage  
door opener can injure themselves or others.  
The garage door could close and cause  
serious injury or death.  
• Strip 1/4" of insulation from one end of the bell  
wire; connect the wire to the two screw terminals  
on the back of the Door Control by color:  
white to 2 and white/red to 1.  
Install the Door Control (or any additional push  
buttons) out of the reach of children and away  
from all moving parts of the door and door  
hardware, but where the garage door is visible.  
Do not allow children to operate the push  
button(s) or the remote control transmitter(s).  
Locate the Door Control within sight of the  
door at a minimum height of 5 feet where small  
children cannot reach, and away from all  
moving parts of the door and door hardware.  
Fasten the Multi-Function Door Control Panel  
securely with 6ABx1" screws. If installing into  
drywall, drill 5/32" holes and use the anchors  
provided.  
A moving garage door could injure someone  
under it. Activate the opener only when the  
door is properly adjusted, you can see it clearly,  
and there are no obstructions to door travel.  
• Run the bell wire up the wall and across the ceiling  
to the opener. Use insulated staples to secure the  
wire in several places. Be careful not to pierce the  
wire with a staple, thereby resulting in a short.  
Do NOT connect the power and operate the  
opener at this time. The trolley will travel to the  
full open position but will not return to the  
close position until the sensor beam is  
connected and properly aligned.  
• Receiver terminals and the antenna are located on  
the right side panel of the opener. Position the  
antenna wire as shown.  
See Safety Reversing Sensor Instructions  
beginning on page 17.  
• Then connect the bell wire to the opener terminal  
screws: white to 2 and white/red to 1.  
Remember to affix the User Safety Instruction  
label to the wall near the Door Control, and the  
Maintenance Instruction label in a prominent  
location on the inside of the garage door.  
Outside Keylock Accessory Connections  
To opener terminal screws: white to 2; white/red to 1  
If the label adhesive will not adhere to your garage  
wall surface (or becomes loose with time) use tacks  
to secure the label alongside the Door Control.  
Multi-Function  
Door Control Panel  
Terminal Screws  
Page 28 explains how to operate the opener using  
the lighted push bar and the Lock & Light features  
available on the Multi-Function Door Control Panel.  
RED  
WHI  
- 2  
TE  
- 1  
Hardware Shown Actual Size  
6ABx1" Screw  
Insulated Staples  
Multi-Function Door Control  
Dry Wall Anchors  
Lock Button  
Opener  
Terminal  
Screws  
2-Conductor  
Bell Wire  
LOCK  
LIGHT  
1
2
3
Light Button  
9
9
1
1
7
3
7
3
5
5
KG  
KG  
Door  
Control  
Button  
AVERTISSEMENT: Pour réduire les risques de  
blessures mortelles par happement, après tout  
réglage de la force de déclenchement ou des  
seuils de fin de course s'assurer que le sens de  
la course s'inverse lorsque la porte entre en  
contact avec un object de 13 mm (1 po) de  
hauteur (ou un madrier de  
plat) posé sur le sol. Effectuer les reglages  
selon les procédures décrites dans la notice.  
PART NO: Nº DE PIÈCE:  
2
x
4
de section,  
à
D.O.C. CERT. NO. DATE:  
Sears Roebuck  
Sears Canada Inc., Toronto  
Assembled in Mexico Assemblé du Mexique  
PAT. #RE29,525; 4,750,201; 4,806,930 Other Patents Pending.  
&
Co.  
-
M.D.C. CERT. NO. 132C2105-1  
Multi-Function  
Door Control Panel  
Right Side  
Panel of  
Opener  
Antenna  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 7  
Install the Lights and the Lenses  
Install the lights  
• Install a 75 watt maximum light bulb in the socket.  
The light will turn ON and remain lit for  
approximately 4-1/2 minutes when power is  
connected. Then the light will turn OFF.  
Lens  
Guide  
75 Watt  
Maximum  
Light Bulb  
• If the bulbs burn out prematurely due to vibration,  
replace with a "Garage Door Opener" bulb.  
Lens  
Tab  
75 Watt  
Maximum  
Light Bulb  
Install the lenses  
• Slide lenses into guides. Snap bottom tabs into  
lens slots.  
Lens Slot  
For convenience, the lenses may be installed  
after Adjustment Step 4 on page 26.  
Lens Tab  
• Reverse the procedure to remove the lenses.  
Installation Step 8  
Attach the Manual Release  
Rope and Handle  
WARNING  
Do not use the red handle to pull the door  
open or closed. The rope knot could become  
untied and you could fall. Use the manual  
release only to disengage the trolley and, if  
possible, only when the door is closed.  
Garage doors are heavy. If the door is open  
when the handle is pulled, the door could  
close inadvertently if it is not properly  
balanced. Serious injury may result to persons  
under the door. Make sure the doorway is clear  
of persons and obstructions before pulling  
handle when door is open.  
Overhand  
Knot  
Trolley  
Trolley  
Release Arm  
Rope  
Thread one end of the rope through the hole in the  
top of the red handle so "NOTICE" reads right side  
up as shown. Secure with an overhand knot.  
NOTICE  
Manual  
Release Handle  
Overhand  
Knot  
The knot should be at least 1" from the end of the  
rope to prevent slipping.  
• Thread the other end of the rope through the hole in  
the release arm of the outer trolley.  
• Adjust rope length so the handle is 6 feet above the  
floor. Secure with an overhand knot.  
If it is necessary to cut the rope, heat seal the cut  
end with a match or lighter to prevent unraveling.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 9  
Electrical Connections  
WARNING  
To prevent electrocution or fire, installation  
and wiring must be in compliance with local  
electrical and building codes.  
To reduce the risk of electric shock, your garage  
door opener has a grounding type plug with a third  
grounding pin. This plug will only fit into a grounding  
type outlet.  
If the plug doesn't fit into the outlet you have,  
contact a qualified electrician to install the proper  
outlet.  
To avoid installation difficulties,  
do not run the opener at this time.  
Right  
Wrong  
• Do not change the plug in any way.  
• Do not use a 2-wire adapter.  
• Do not use an extension cord.  
If permanent wiring is required by your local code, refer to the following procedure:  
WARNING  
To prevent electrocution, remove power from  
the garage door opener and from the circuit  
you plan to use for the permanent  
connection.  
Permanent wiring  
connection  
• To make a permanent connection through the  
7/8" diameter hole in the top of the opener  
(according to local code):  
• Remove the opener cover screws and set the  
cover aside.  
Ground Tab  
• Remove the attached 3-prong cord.  
Green  
• Connect the black (line) wire to the screw on the  
brass terminal; the white (neutral) wire to the  
Ground  
Screw  
screw on the silver terminal; and the ground wire  
to the green ground screw. The opener must be  
Black  
Wire  
Ground Wire  
grounded.  
• Reinstall the cover.  
To avoid installation difficulties,  
do not run the opener at this time.  
White Wire  
Black  
Wire  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Protector System®  
Information you'll need before you begin the installation of the safety reversing sensor.  
The safety reversing sensor must be connected  
and aligned correctly before the garage door  
opener will move in the down direction. This is a  
required safety device and cannot be disabled.  
WARNING  
Without a properly working safety reversing  
sensor, persons (particularly children) could  
Installation procedures are the same for sectional  
be injured or killed by a closing garage door.  
and one-piece doors.  
Read and follow all instructions.  
To protect small children, install the safety  
reversing sensor so that the beam will be no  
higher than 4"-6" above the garage floor.  
Disconnect power to the garage door opener  
before installing the safety reversing sensor.  
Sensor Beam  
4-6" max.  
above floor  
Sensor Beam  
4-6" max.  
above floor  
Invisible Light Beam  
Protection Area  
Figure 1: Facing the door from inside the garage  
Be sure power to the opener is disconnected.  
The brackets must be securely fastened to a solid  
surface such as the studs on either side of the door,  
or add a piece of wood at each location if installing in  
masonry construction.  
The sending eye transmits an invisible light beam to  
the receiving eye.The units can be installed on  
either side of the garage door as long as the sun  
never shines directly into the receiving eye lens.  
The invisible light beam path must be unobstructed.  
No part of the garage door (or door tracks, springs,  
hinges, rollers or other hardware) can interrupt the  
beam while the door is closing. If it does, use a piece  
of wood to build out each sensor mounting location to  
the minimum depth required for light beam clearance.  
Look at the label on the connector end of each case  
to identify the sensors.  
The brackets must be connected and fastened so  
that the sending and receiving eyes face each other  
as shown in Figure 1.  
If an obstruction breaks the light beam while the  
garage door is closing, the door will stop and  
reverse to full open position; and the opener lights  
will flash for 5 seconds.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 2  
Installation Step 10  
Install the Safety Reversing Sensor  
Garage WALL or DOOR TRACK Installation  
Mounting Bracket  
With Square Holes  
"C" Wrap  
Figures 2, 3 and 4 show recommended assembly of  
bracket(s) and "C" wrap based on the wall install  
ation of the sensors on each side of the garage door  
as shown on page 17, or on the garage door tracks  
themselves.  
#10-32x3/8"  
Screws  
#10-32  
Lock Nuts  
Figures 5 and 6 are variations which may fit your  
installation requirements better. Make sure the  
wraps and brackets are aligned so the sensors  
will face each other across the garage door.  
Garage DOOR Track Installation  
Figure 3  
1/4"-20 Lock Nuts  
Inside  
Garage  
Door Track  
Mounting Bracket  
with Square Holes  
Garage  
Wall  
For Garage Wall or Door Track Installation  
Drill 3/8"  
Holes  
Fasten the "C" wraps to the mounting brackets  
having square holes, using the hardware shown in  
Figure 2.  
"C" Wrap  
For Door Track Installation Only  
Discard slotted bracket. Drill 3/8" holes in each  
track and fasten securely with hardware as shown  
in Figure 3.  
1/4"-20x1/2"  
Carriage Bolts  
For Wall Installation  
Figure 4  
Garage WALL Installation  
• Connect each assembly to a slotted bracket, using  
the hardware shown in Figure 4. Note alignment  
of brackets for left and right sides of the door.  
1/4x1-1/2"  
1/4-20x1/2" Carriage Bolts  
(with square shoulder)  
Lag Screws  
Inside  
Garage  
Wall  
• Finger tighten the lock nuts.  
Use bracket mounting holes as a template to locate  
and drill (2) 3/16" diameter pilot holes on both sides  
of the garage door, 4"-6" above the floor (but not  
exceeding 6"). See warning on page 17.  
• Attach bracket assemblies with 1/4"x1-1/2"  
lag screws as shown in Figure 4.  
"C" Wrap  
Mounting Bracket  
with Slot  
Mounting Bracket  
with Square Holes  
• Adjust right and left side bracket assemblies to the  
same distance out from mounting surface. Make  
sure all door hardware obstructions are cleared.  
Tighten the nuts securely.  
1/4"-20  
Lock Nuts  
Alternate Floor Mount  
Alternate Wall Mount  
Figure 5  
Figure 6  
Inside  
Garage  
Wall  
Inside  
Garage  
Wall  
Indicator  
Light  
Sensor  
Mounting Bracket  
with Slot  
Mounting Bracket  
with Square Holes  
Mounting Bracket  
with Square Holes  
Mounting Bracket  
with Slot  
"C" Wrap  
"C" Wrap  
Attach with  
concrete anchors  
(not provided)  
Sensor  
Indicator Light  
Garage  
Floor  
Garage  
Floor  
Hardware Shown Actual Size  
#10x32  
Lock Nut  
1/4x1-1/2"  
Lag Screw  
1/4"-20x1/2"  
Carriage Bolts  
#10-32x3/8"  
Screw  
1/4"-20  
Lock Nut  
Staples  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Sensor  
• Insert the wire connector into each  
sensor and push until you hear a  
click, Figure 7. The white tab on the  
sensor should be flush with the  
back of the connector.  
Figure 7  
Tab should be  
flush with back  
of connector  
White Tab  
Push connector in  
until you hear a click  
Wire Connector  
Figure 8  
Connect Wire to  
Opener Terminals  
— Finished Ceiling —  
Bell Wire  
Wall Control  
Connections  
(dotted line)  
Sensor  
Connections  
1
2
3
Bell Wire  
OPENER TERMINAL SCREWS  
Center each sensor unit in a "C" wrap with lenses  
pointing toward each other across the door.  
• Secure sensors with the hardware shown. Finger  
tighten the wing nut on the receiving eye to allow  
for final adjustment. Securely tighten the sending  
eye wing nut.  
Wing Nut  
"C" Wrap  
Wire  
Indicator Light  
Sensor  
Invisible Light Beam  
1/4-20x1-1/2"  
Hex Bolt  
Protection Area  
Sensor  
Sensor  
Run paired wires from both sensors to the opener.  
Use insulated staples to secure the wire to wall  
and ceiling.  
Trouble Shooting  
1. If the sending eye indicator light does not glow  
steadily after installation, check for:  
Strip 1/4" of insulation from each set of wires.  
• Electric power to the opener.  
Separate white and white/black wires sufficiently to  
connect to the opener terminal screws: white to 2  
and white/black to 3.  
• A short in the white or white/black wires. These  
can occur under staples or at screw terminal  
connections.  
• Plug in the opener. Make sure the Lock Feature is  
off. Green indicator lights in both the sending and  
receiving eyes will glow steadily if wiring  
• Incorrect wiring between sensors and opener.  
• An open wire (wire break).  
connections and alignment are correct.  
• Lock switch on Multi-Function Door Control Panel  
is on. Turn it off.  
If the indicator light is off in the receiving eye (and  
the invisible light beam path is not obstructed),  
alignment is required.  
2. If the sending eye indicator light glows steadily but  
the receiving eye indicator light doesn't:  
• Loosen the receiving eye wing nut to allow slight  
rotation of unit. Adjust sensor vertically and/or  
horizontally until the green indicator light glows  
with a steady light.  
• Check alignment.  
• Check for an open wire to the receiving eye.  
Hardware Shown Actual Size  
1/4-20x1-1/2"  
Hex Bolt  
• When indicator lights are glowing steadily in both  
units, tighten the wing nut in the receiving eye unit.  
Wing Nut  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 11  
CAUTION  
Fasten Door Bracket  
To prevent damage to steel, aluminum,  
fiberglass or glass panel doors, always  
reinforce the inside of the door both vertically  
and horizontally with angle iron.  
Follow instructions which apply to your door type  
as illustrated below or on page 21.  
A horizontal brace should be long enough to be secured to 2 vertical supports. A vertical brace should  
cover the height of the top panel.  
The illustration shows one piece of angle iron as the horizontal brace. For the vertical brace, 2 pieces of  
angle iron are used to create a "U"-shaped support. The best solution is to check with your garage door  
manufacturer for an opener installation, door reinforcement kit.  
SECTIONAL Door Installation Procedure  
Header  
Horizontal and vertical reinforcement  
Bracket  
is needed for lightweight garage doors  
(fiberglass, aluminum, steel,  
doors with glass panel, etc).  
Figure 1  
Vertical  
Reinforcement  
Door  
Bracket  
Location  
Lock Washer  
5/16"  
Carriage Bolt  
5/16"-18x2-1/2"  
Door  
Vertical  
Bracket  
Guideline  
Nut  
5/16"-18  
Vertical  
Guideline  
Figure 2  
Inside Edge  
of Door or  
Reinforcement Board  
Door  
Bracket  
• Center the door bracket on the previously marked  
vertical guideline used for the header bracket  
installation.  
Door Bracket  
Plate  
• Position the bracket on the face of the door within  
the following limits:  
A) The top edge of the bracket 2"-4" below the top  
edge of the door.  
Hardware Shown Actual Size  
B) The top edge of the bracket directly below any  
structural support across the top of the door.  
• Mark and drill 5/16" left and right fastening holes.  
Secure the bracket as shown in Figure 1 if there is  
vertical reinforcement.  
Nut 5/16"-18  
Lock Washer 5/16"  
If your installation doesn't require vertical reinforce-  
ment but does need top and bottom fastening holes  
for the door bracket, position the door plate over the  
door bracket as shown in Figure 2. Fasten securely  
with hardware shown in Figure 1.  
Carriage Bolt  
5/16"-18x2-1/2"  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
All ONE-PIECE Door Installation Procedure  
Please read and comply with the warnings and reinforcement instructions on page 20.  
They apply to one-piece doors also.  
Header Wall  
– Finished Ceiling –  
2x4  
Horizontal and vertical  
reinforcement is needed for  
lightweight garage doors  
(fiberglass, aluminum, steel,  
Header  
Bracket  
door with glass panel, etc.).  
Door  
Bracket  
Inside Edge  
of Door or  
Reinforcement Board  
Vertical  
Centerline of  
Garage Door  
Door  
Bracket  
Door Bracket  
Plate  
• Center the bracket (with or without the plate  
Hardware Shown Actual Size  
according to your fastening requirements) on the  
inside face of the door, in line with the header  
bracket as shown. Mark either the left and right, or  
the top and bottom holes.  
• Drill 5/16" pilot holes and fasten the door bracket  
with hardware supplied.  
Nut 5/16"-18  
Lock Washer 5/16"  
Carriage Bolt  
5/16"-18x2-1/2"  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 12  
Connect Door Arm to Trolley  
Follow instructions which apply to your door type  
as illustrated below and on page 23.  
SECTIONAL Doors Only  
Make sure garage door is fully closed. Pull the manual release handle to disconnect the outer trolley  
from the inner trolley. Slide the outer trolley back (away from the door) about 2" as shown in  
Figures 1, 2 and 3.  
Figure 1:  
Figure 2:  
Fasten straight door arm section to outer trolley  
with a clevis pin. Secure the connection with a ring  
fastener.  
Bring arm sections together. Find two pairs of holes  
that line up and join sections. Select holes as far  
apart as possible to increase door arm rigidity.  
• Fasten curved section to the door bracket in the  
same way as shown.  
Inner Trolley  
Outer Trolley  
Lock  
Washers  
5/16"  
Clevis  
Pin  
Rope  
Ring  
Fastener  
Manual  
Release  
Handle  
Nuts  
5/16"-18  
Door  
Straight  
Bracket  
Door Arm  
Screws  
5/16"-18x7/8"  
Curved  
Door Arm  
Clevis Pin  
Figure 1  
Hole Alignment Alternative  
Figure 2  
Door Bracket  
Figure 3:  
If holes in curved arm are above holes in straight  
arm, disconnect straight arm. Cut about 6" from  
the solid end. Reconnect to trolley with cut end  
down as shown.  
• Bring arm sections together.  
• Find two pairs of holes that line up and join with  
screws, lock washers and nuts.  
Lock  
Washers  
5/16"  
Hardware Shown Actual Size  
Nuts  
5/16"-18  
Screws  
5/16"-18x7/8"  
Nut 5/16"-18  
Ring Fastener  
Lock Washer 5/16"  
Figure 3  
Cut This End  
Clevis Pin  
5/16"x1"  
Hex Screw  
5/16"-18x7/8"  
Proceed to Adjustment Step 1, page 24. Trolley will re-engage automatically when the opener is operated.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
All ONE-PIECE Doors  
Assemble the Door Arm:  
Door  
Bracket  
Ring  
Fasten the straight and curved door arm sections  
together to the longest possible length (with a 2 or  
3 hole overlap).  
Fastener  
Nuts  
5/16"-18  
Lock  
Washers  
5/16"  
Straight  
Door Arm  
• With the door closed, connect the straight door  
arm section to the door bracket with a clevis pin.  
Clevis Pin  
Curved  
Door Arm  
• Secure with a ring fastener.  
Screws  
5/16"-18x7/8"  
On one-piece doors, before connecting the door arm to the trolley the travel limits must be adjusted. Limit  
adjustment screws are located on the left side panel as shown on page 24. Follow adjustment procedures  
below.  
Fully Closed  
Trolley  
Fully Open  
Trolley  
Door Arm  
Door Arm  
Door Arm  
Connector Hole  
Connector Hole  
Door Arm  
Door with  
Backward Slant  
Closed  
Door  
Open Door  
Adjustment Procedures for One-Piece Doors  
Open Door Adjustment:  
Decrease UP limit  
Closed Door Adjustment:  
Decrease DOWN limit  
• Turn the UP limit adjustment screw counter-  
clockwise 5-1/2 turns.  
• Turn the DOWN limit adjustment screw clockwise 5  
complete turns.  
• Press the Door Control push bar. The trolley will  
travel to the fully open position.  
• Press the Door Control push bar. The trolley will  
travel to the fully closed position.  
• Manually raise the door to the open position  
(parallel to the floor), and lift the door arm to the  
trolley. The arm should touch the trolley just in  
back of the door arm connector hole. Refer to the  
fully open trolley/door arm positions in the  
illustration. If the arm does not extend far enough,  
adjust the limit further. One full turn equals 2" of  
trolley travel.  
• Manually close the door and lift the door arm to the  
trolley. The arm should touch the trolley just ahead  
of the door arm connector hole. Refer to the fully  
closed trolley/door arm positions in the illustration. If  
the arm is behind the connector hole, adjust the limit  
further. One full turn equals 2" of trolley travel.  
Connect the door arm to the trolley.  
Close the door and join the curved arm to the connector hole in the trolley with the remaining clevis pin.It may be  
necessary to lift the door slightly to make the connection.  
• Secure with a ring fastener.  
• Run the opener through a complete travel cycle. If the door has a slight "backward" slant in full open position as  
shown in the illustration, decrease the UP limit until the door is parallel to the floor.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjustment Section: Pages 24 – 26  
Adjustment Step 1  
Adjust the UP and DOWN Limits  
WARNING  
Improper adjustment of the travel limits will  
interfere with the proper operation of the safety  
reverse system. The door might not reverse  
when required and could seriously injure or kill  
someone under it. Test the safety reverse  
system following all adjustments to the travel  
limits. See page 26.  
Do not make any limit adjustments until the  
safety reversing sensors are completely  
installed.  
Limit adjustment settings regulate the points at  
which the door will stop when moving up or down.  
The door will stop in the up direction if anything  
interferes with door travel. The door will reverse in  
the down direction if anything interferes with the  
door travel (including binding or unbalanced doors).  
To operate the opener, press the Door Control push  
bar. Run the opener through a complete travel  
cycle.  
• Does the door open and close completely?  
• Does the door stay closed and not reverse  
unintentionally when fully closed?  
If your door passes both of these tests, no limit  
adjustments are necessary unless the reversing test  
fails (See page 26).  
Adjustment procedures are outlined below. Run  
the opener through a complete travel cycle after  
each adjustment.  
Left Side  
Limit  
Panel  
Adjustment  
Screws  
Repeated operation of the opener during  
adjustment procedures may cause the motor to  
overheat and shut off. Simply wait 15 minutes  
and try again.  
Read the procedures carefully before continuing on  
to Adjustment Step 2. Use a screwdriver to make  
limit adjustments.  
Adjustment Label  
How and When to Adjust the Limits  
If the door does not open completely  
but opens at least five feet  
If the opener reverses in fully closed position  
Decrease down travel. Turn the DOWN limit  
adjustment screw clockwise. One turn equals 2" of  
travel.  
Increase up travel. Turn the UP limit adjustment  
screw clockwise. One turn equals 2" of travel.  
If door does not open at least 5 feet: Adjust the  
UP (open) force as explained in Adjustment Step 2.  
If the door reverses when closing and  
there is no visible interference to travel cycle  
If the door does not close completely  
If the opener lights are flashing, the Safety Reversing  
Sensor is obstructed. Remove the obstruction.  
Increase down travel. Turn the DOWN limit  
adjustment screw counterclockwise. One turn  
equals 2" of travel.  
Test the door for binding: Pull the manual release  
handle. Manually open and close the door. If the door  
is binding, call for garage door service. If the door is  
not binding or unbalanced, adjust the DOWN (close)  
force. See Adjustment Step 2.  
If door still won't close completely, try lengthening  
the door arm. (See page 22.)  
If you have adjusted the door arm to the maximum  
length and the door still will not close completely,  
lower the header bracket. See Installation Step 1,  
pages 8 and 9.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjustment Step 2  
Adjust the Force  
WARNING  
Too much force on the door will interfere with  
the proper operation of the safety reverse  
system. The door might not reverse properly  
when required and could seriously injure or  
kill someone under it. Do not increase the  
force beyond the minimum amount required to  
close the door. Do not use the force  
adjustments to compensate for a binding or  
sticking garage door. Test the safety reverse  
system following all adjustments to force  
levels. See page 26.  
Force adjustment controls are located on the right  
side panel of the opener. Force adjustment settings  
regulate the amount of power required to open and  
close the door.  
The door will stop in the up direction if anything  
interferes with its travel. The door will reverse in the  
down direction if anything interferes with its travel  
(including binding or unbalanced doors).  
If the forces are set too light, door travel may be  
interrupted by nuisance reversals in the down  
direction and stops in the up direction. Weather  
conditions can affect the door movement, so  
occasional adjustment may be needed.  
Force  
Adjustment  
Controls  
The maximum force adjustment range is 260  
degrees, about 3/4 of a complete turn. Do not force  
controls beyond that point. Turn force adjustment  
controls with a screwdriver.  
1
2
3
TO PROGRAM RECEIVER CODE  
FOR EACH REMOTE CONTROL  
1. Press and HOLD remote control  
transmitter push button.  
2. Press receiver code button. The opener  
light will flash once.  
9
9
1
1
3. Release transmnitter button. Opener  
has learned code.  
7
3
7
3
TO ERASE ALL RECEIVER CODES  
5
5
1. Press and HOLD receiver code button.  
Green indicator light alongside will turn  
ON.  
K
G
K
G
This device complies  
with FCC Rules Part  
15. Operation of this  
device is subject to the  
following conditions:  
1. This device may  
not cause harmful  
interference. 2. This  
device must accept  
any interference  
WARNING: To reduce the risk of severe injury  
or death by entrapment, when adjusting either  
the force or limits of travel controls ensure that  
inch object (or  
board laid flat). See instructions for proper  
adjustment procedure.  
AVERTISSEMENT: Pour réduire les risques de  
blessures mortelles par happement, après tout  
réglage de la force de déclenchement ou des  
seuils de fin de course s'assurer que le sens de  
la course s'inverse lorsque la porte entre en  
contact avec un object de 13 mm (1 po) de  
2. When light turns OFF (about  
6
seconds) ALL codes are erased from  
opener memory.  
the door reverses on  
a
1
a
2
x
4
that may be received,  
including interference  
that may cause  
hauteur (ou un madrier de  
plat) posé sur le sol. Effectuer les reglages  
selon les procédures décrites dans la notice.  
PART NO: Nº DE PIÈCE:  
2
x
4
de section,  
à
undesired operation.  
Sears Roebuck  
Sears Canada Inc., Toronto  
Assembled in Mexico Assemblé du Mexique  
PAT. #RE29,525; 4,750,201; 4,806,930 Other Patents Pending.  
&
Co.  
D.O.C. CERT. NO. DATE:  
-
M.D.C. CERT. NO. 132C2105-1  
9
9
1
1
7
7
3
3
5
5
KG  
KG  
Adjustment Label  
Right Side Panel  
of Opener  
How and When to Adjust the Forces  
Test the DOWN (close) force  
If the door doesn't open at least 5 feet  
Grasp the door bottom when the door is about  
halfway through DOWN (close) travel. The door  
should reverse. (Reversal halfway through down  
travel does not guarantee reversal on a one-inch  
obstruction. See page 26.) If the door is hard to  
hold or doesn't reverse, decrease the DOWN (close)  
force by turning the control counterclockwise.  
Increase UP (Open) force by turning the control  
clockwise. Make 10 degree turn adjustments until  
door opens completely. Re-adjust the UP limit if  
necessary. After each adjustment, run the opener  
through a complete travel cycle.  
If the door reverses during the down (close) cycle  
and the opener lights aren't flashing  
Make 10 degree turn adjustments until the door  
reverses normally. After each adjustment, run the  
opener through a complete cycle.  
Increase DOWN (close) force by turning the control  
clockwise. Make 10 degree turn adjustments until the  
door completes a close cycle. After each adjustment,  
run the opener through a complete travel cycle. Do  
not increase the force beyond the minimum  
amount required to close the door.  
Test the UP (open) force  
Grasp the door bottom when the door is about  
halfway through UP (open) travel. The door should  
stop. If the door is hard to hold or doesn't stop,  
decrease UP (open) force by turning the control  
counterclockwise. Make 10 degree turn adjustments  
until the door stops easily. After each adjustment,  
run the opener through a complete travel cycle.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjustment Step 3  
WARNING  
Test the Protector System®  
Without a properly working safety reversing  
sensor, persons (particularly children) could be  
seriously injured or killed if trapped by a closing  
garage door. Repeat this test once a month.  
• Press the remote control push button to open the  
door.  
• Place the opener carton in the path of the door.  
• Press the remote control push button to close the  
door. The door will not move more than an inch,  
and the opener light(s) will flash.  
The garage door opener will not close from a  
remote if the indicator light in either sensor is  
off (alerting you to the fact that the sensor is  
misaligned or obstructed).  
The garage door can be closed by pressing and  
holding the Door Control push bar until down travel  
is completed.  
Professional service is required if the opener  
closes the door when the safety reversing  
sensor is obstructed.  
Safety Reversing Sensor  
Safety Reversing Sensor  
Adjustment Step 4  
Test the Safety Reverse System  
WARNING  
Failure to test and adjust the safety reverse  
system may result in serious injury or death  
from a closing garage door. Repeat this test  
once a month and adjust as needed.  
GARAGE DOOR  
Test:  
• Place a 2x4 laid flat on the floor, centered under  
the garage door.  
• Operate the door in the down direction. The door  
must reverse on striking the obstruction.  
Adjustment:  
If the door stops on the obstruction, it is not traveling  
far enough in the down direction.  
• Increase the DOWN limit by turning the DOWN  
limit adjustment screw counterclockwise 1/4 turn.  
• Repeat the test.  
On a sectional door, make sure limit  
adjustments do not force the door arm beyond a  
straight up and down position. See the  
illustration on page 22.  
• When the door reverses on the 2x4 laid flat,  
remove the obstruction and run the opener through  
3 or 4 complete travel cycles to test adjustment.  
2x4 laid flat  
Important safety check:  
Repeat Adjustment Steps 1, 2 and 4 after:  
If the door will not reverse after repeated  
adjustment attempts, call for professional  
garage door service.  
• Each adjustment of door arm length, force controls  
or limit controls.  
• Any repair to or adjustment of the garage door  
(including springs and hardware).  
• Any repair to or buckling of the garage floor.  
• Any repair to or adjustment of the opener.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
WARNING  
WARNING  
To reduce the risk of severe injury or death to persons:  
1. READ AND FOLLOW ALL INSTRUCTIONS.  
2. Do not permit children either to operate or to play with the opener. Keep remote control in a  
location inaccessible to children.  
3. Operate opener only when the door is in full view and free from any obstruction. Keep the door in  
sight until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.  
4. Check safety reversal system monthly. See page 26. The garage door MUST reverse on contact  
with a 2x4 board laid flat placed on the floor. If an adjustment is made to either the force or the limit  
of travel, both adjustments may be needed and the safety reversal system must be checked.  
Failure to properly adjust the opener may result in severe injury or death.  
5. If possible, use the manual release only when the door is in a closed position. Caution should be  
taken whenever the disconnect cord is actuated with the door open. Weak or broken springs may  
cause the door to fall rapidly, causing injury or death to persons.  
6. KEEP GARAGE DOORS PROPERLY BALANCED. See page 3. An improperly balanced door may not  
reverse when required and could result in severe injury or death. Repairs to cables, spring  
assemblies and other hardware must be made by a professional garage door person.  
7. Disconnect the electric power from the garage door opener before making any repairs or removing  
the covers.  
8.  
SAVE THESE INSTRUCTIONS.  
Care of Your Opener  
The remote control transmitter:  
Limit and force adjustment controls  
The opener must learn the code of any new remote  
control. Page 29 explains how to program your  
receiver and how to erase all codes if required. Self  
service of your radio controls and remote controls is  
not recommended. If service is needed, call the toll-  
free number listed on the back page.  
Limit Controls  
Force Controls  
9
9
1
1
7
7
3
3
5
5
KG  
KG  
Adjustment Label  
(Located on the left side panel)  
Adjustment Label  
(Located on the right side panel)  
The remote control battery:  
The green test light will glow and the opener will  
operate when the remote control is activated.  
Weather conditions may cause some minor  
changes in door operation requiring some re-  
adjustments, particularly during the first year of  
operation.  
If the test light is dim or off, replace the battery.  
The 12V battery should produce power for at least a  
year.  
Pages 24 and 25 refer to the limit and force  
adjustments. Only a screwdriver is required. Follow  
the instructions carefully.  
Dispose of your old battery properly.  
Repeat the safety reverse test (page 26) after any  
adjustment of limits or force.  
Maintenance Schedule  
Once a Month  
Once a Year  
Manually operate door. If it is unbalanced or  
Oil door rollers, bearings and hinges.  
binding, call for professional garage door service.  
The opener does not require additional lubrication.  
Do not grease the door tracks.  
Check to be sure door opens & closes fully.  
Adjust limits and/or force if necessary. (See pages  
24 and 25.)  
Repeat the safety reverse test. Make any  
necessary adjustments. (See page 26.)  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation of Your Opener  
Activate the opener with any of the following:  
The Remote Control Transmitter. Hold push  
button down until the door starts to move.  
WARNING  
The Door Control. Hold push bar down until the  
door starts to move.  
Weak or broken springs could allow an open  
door to fall (either rapidly or unexpectedly),  
resulting in serious injury, death or property  
damage. If possible, use the manual release  
rope and handle only when the door is fully  
closed.  
The Outside Keylock or Keyless Entry System.  
(See Accessories)  
When the opener is activated with the safety  
reversing sensor installed and correctly aligned:  
1. If open, the door will close. If closed, the door will  
open.  
To open the door  
manually:  
2. If closing, the door will reverse.  
Trolley  
Release Arm  
The door should be  
fully closed if  
possible. Pull down on  
the red manual  
release handle and lift  
the door manually.  
To reconnect the door  
to the opener, press  
3. If opening, the door will stop (allowing space for  
entry and exit of pets and for fresh air).  
Trolley  
4. If the door has been stopped in a partially open  
position, it will close.  
NOTICE  
5. If obstructed while closing, the door will reverse.  
6. If obstructed while opening, the door will stop.  
Manual  
Release Handle  
(Pull Down)  
7. The garage door will reverse in the closing cycle  
when the invisible beam is broken. If fully open, the  
door will not close when the beam is broken. The  
sensor has no effect in the opening cycle.  
the Door Control  
push bar.  
Manual disconnect  
position  
If the sensor is not installed, or is not aligned correctly,  
the door won't close from any remote transmitter. You  
can close the door with the Door Control, the Outside  
Keylock, or Keyless Entry, however, if you activate  
them until down travel is complete. If you release them  
too soon, the door will reverse.  
The lockout feature  
prevents the trolley from  
reconnecting auto-  
Trolley  
Release Arm  
matically. Pull the red  
manual release handle  
down and back (toward  
the opener). The door  
can then be raised and  
lowered manually as  
often as necessary. To  
disengage the lockout  
feature, pull the manual  
handle straight down.  
The trolley will reconnect  
on the next UP or  
Trolley  
The opener lights will blink for 5 seconds when the  
safety reversing sensor causes the door to reverse.  
NOTICE  
The Opener Lights will turn on under the following  
conditions: When the opener is initially plugged in;  
when the power is interrupted; when the opener is  
activated. It will turn off automatically after 4-1/2  
minutes or provide constant light when the Light  
feature is activated. Bulb size is 75 watts maximum.  
Manual  
Release Handle  
(Pull Down & Back  
Towards Opener)  
Lockout position  
DOWN operation.  
Operation of the Door Controls  
(both are not included with all models)  
Lighted Door Control Button:  
Lighted Push Bar - Door Control Panel: Press to  
open or close the door.  
Lock Feature - Door Control Panel: The Lock  
feature is designed to prevent operation of the door  
from remote controls. However, the door will open  
and close from the Door Control push bar, the  
Outside Keylock and the Keyless Entry Accessories.  
Press again to reverse the door during the closing  
cycle or to stop the door while it's opening.  
To Activate: Press and hold the Lock button for  
2 seconds. The push bar light will flash as long as  
the Lock feature is on.  
Light Feature - Door Control Panel: Press the  
Light button. If the opener light is off, it will turn on.  
If the opener light is on, (even in the 4-1/2 minute  
automatic cycle) it will turn off.  
To Turn Off: Press and hold the Lock button for  
2 seconds again.The push bar light will stop  
flashing. Normal operation will resume. The Lock  
feature will also turn off whenever the "Smart"  
button on the opener panel is activated.  
But if you use the Light button to turn the light(s) on  
and then activate the opener, the light(s) will turn off  
after 4-1/2 minutes.  
The Light button will not control the opener lights  
when the door is in motion.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Receiver and Remote Control Programming  
NOTICE: To comply with FCC/IC rules, adjustment or modifications of  
this receiver and/or transmitter are prohibited, except for changing the  
code setting or replacing the battery. THERE ARE NO OTHER USER  
SERVICEABLE PARTS.  
WARNING  
Children operating or playing with a garage  
door opener can injure themselves or others.  
The garage door could close and cause  
serious injury or death. Do not allow children  
to operate the Door Control or remote control  
transmitter(s).  
Your garage door opener receiver and remote control  
transmitter have been set at the factory to a matching  
code. The door will activate when the remote control  
push button is pressed.  
A moving garage door could injure or kill  
someone under it. Activate the opener only  
when you can see the door clearly, it is free of  
obstructions, and is properly adjusted.  
Your "Smart" garage door opener will operate with:  
• up to four "Smart" remote control transmitters  
(with green indicator lights),  
• a Keyless Entry System, and  
• code switch transmitters with red indicator lights.  
Below are instructions for programming your opener  
to match any additional remotes you may purchase.  
See available accessories on page 34.  
To Add A Remote  
Figure 1  
1. Press and hold the remote push button. See  
Figure 1.  
Single Function Remote Control  
2. Then press and release the "Smart" button on the  
right side of the opener in Figure 2. The opener  
lights will flash once.  
Battery  
Indicator Light  
3. Release the remote push button.  
Now the opener will operate when the remote control  
push button is pressed.  
Push Button  
If you release the remote control push button  
before the opener lights flash, the opener will not  
accept the code.  
Figure 2  
To Erase All Remote Control Codes  
• Press and hold the "Smart" button on the opener  
panel until the indicator light turns off (about 6  
seconds). All the codes the opener has learned  
will be erased.  
Garage Door Opener  
(With "Smart" Button)  
1
2
3
• To reprogram, repeat Steps 1 - 3 for each remote  
control in use.  
9
9
1
1
7
7
3
3
5
5
KG  
KG  
Code programming instructions are also located  
on the opener panel.  
"Smart"  
Button  
Indicator  
Light  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Having a Problem?  
Situation  
Probable Cause & Solution  
1. Does the opener have electric power? Plug a lamp into the outlet. If it doesn't light,  
check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.)  
2. Have you disabled all door locks? Review installation instruction warnings on page 7.  
3. Is there a build-up of ice or snow under the door? The door may be frozen to the  
ground. Remove any restriction.  
The opener doesn't  
operate from either  
the Door Control or  
the remote control:  
4. The garage door spring may be broken. Have it replaced.  
5. Repeated operation may have tripped the overload protector in the motor. Wait 15  
minutes. Try again.  
Opener operates from  
the remote, but not  
from Door Control:  
1. Is the door control lit? If not, remove the bell wire from the opener terminals. Short the  
red and white terminals by touching both terminals at the same time with a piece of  
wire. If the opener runs, check for a faulty wire connection at the door control, a short  
under the staples, or a broken wire.  
2. Are the wiring connections correct? Review Step 6, page 14.  
The door operates  
from the Door  
Control, but not from  
the remote control:  
1. If your model has the Lock feature, turn it off.  
2. Is the wall push button flashing? Your opener needs to re-learn a remote control  
code. Refer to instructions on the opener panel.  
3. Does the battery test light glow when the remote control push button is pressed? If  
not, replace the battery.  
4. Program the receiver to match the remote control code.  
5. Repeat the receiver programming procedure with all remote controls.  
The remote control  
has short range:  
1. Check the battery test light. If the light is dim, replace the battery.  
2. Change the location of the remote control in your car.  
3. Check to be sure the antenna on the side or back panel of opener extends fully  
downward.  
4. Some installations may have shorter range due to a metal door, foil backed insulation,  
or metal garage siding.  
Opener noise is  
disturbing in living  
quarters of home:  
If operational noise is a problem because of proximity of the opener to the living  
quarters, the Vibration Isolator Kit 41A3263 can be installed. This kit was designed to  
minimize vibration to the house and is easy to install.  
The garage door  
opens and closes  
by itself:  
1. Be sure that all remote control push buttons and battery indicator lights are off.  
2. Remove the bell wire from the door control terminals and operate from the remote  
only. If this solves the problem, the door control is faulty (replace), or there is an  
intermittent short on the wire between the door control and the opener.  
The door doesn't  
open completely:  
1. If the door has been working properly but now doesn't open all the way, increase the  
up force. See page 25.  
2. Is something obstructing the door? Remove the obstruction or repair the door.  
3. If door opens at least 5 feet, the travel limits may need to be increased. One turn  
equals 2 inches of travel. See page 24.  
Repeat the safety reverse test after the adjustment is complete.  
The door stops but  
doesn't close  
completely:  
Review the travel limits adjustment procedures on page 24.  
Repeat the safety reverse test after any adjustment of door arm length, close  
force or down limit.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Having a Problem? (continued)  
Situation  
Probable Cause & Solution  
The door opens but  
won't close:  
1. If the opener lights blink, check the safety reversing sensor. See page 19.  
2. If the opener lights do not blink and it is a new installation, check the down force.  
See Adjustment Step 2, page 25. For an existing installation, see below.  
Repeat the safety reverse test after the adjustment is complete.  
The door reverses for  
no apparent reason  
and opener lights  
don't blink:  
1. Is something obstructing the door? Pull the manual release handle. Operate the door  
manually. If it is unbalanced or binding, call for professional garage door service.  
2. Clear any ice or snow from the garage floor area where the door closes.  
3. Review the force adjustment procedures on page 25.  
4. If door reverses in the fully closed position, decrease the travel limits (page 24).  
Repeat safety reverse test after adjustments to force or travel limits. The need  
for occasional adjustment of the force and limit settings is normal. Weather  
conditions in particular can affect door travel.  
Check the safety reversing sensor. Remove any obstruction or align the receiving eye.  
See page 19.  
The door reverses for  
no apparent reason  
and opener lights  
blink for 5 seconds  
after reversing:  
The opener lights:  
. . . don't turn on:  
Replace the light bulbs (75 watts maximum). Use a standard neck garage door opener  
bulb if regular bulb burns out.  
. . . don't turn off:  
Is the Light feature on? Turn it off.  
The door may be out of balance or the springs are broken. Close the door and use the  
manual release to disconnect the trolley. Open and close the door manually. A properly  
balanced door will stay in any point of travel while being supported entirely by its  
springs. If it does not, disconnect the opener and call a professional garage door  
serviceman. Do not increase the force to operate the opener.  
The opener strains or  
maximum force is  
needed to operate  
door:  
The opener motor  
hums briefly, then  
won't work:  
1. The garage door springs are broken. See above.  
2. If the problem occurs on the first operation of the opener, door may be locked.  
Disable the door lock. If the belt was removed and reinstalled, the motor may be out  
of phase. Remove the belt; cycle the motor to the down position. Observe the drive  
sprocket. When it turns in a clockwise direction and stops in the down position,  
reinstall the belt.  
Repeat the safety reverse test after the adjustment is complete.  
The opener won't  
operate due to  
power failure:  
1. Use the manual release to disconnect the trolley. The door can be opened and  
closed manually. When the power is restored, press the Door Control push bar and  
trolley will automatically reconnect (unless trolley is in lockout position.) See page 28.  
2. The Outside Quick Release accessory (for use on garages with no service door)  
disconnects the trolley from outside the garage in case of power failure.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts  
Rail Assembly Parts  
5
3
1
6
7
2
KEY  
NO.  
PART  
NO.  
4
DESCRIPTION  
1
2
3
4
5
6
7
1A995  
Master link kit  
41A3588  
41B3869-1  
183B99  
Belt pulley bracket  
Complete trolley assembly  
One-piece T-rail  
41A3589  
41B4103  
109B33  
Full belt assembly  
Tensioner assembly  
Trolley clip  
Installation Parts  
2
3
6
LOCK  
LIGHT  
4
12VDC  
5
1
NOTICE  
KEY PART  
NO.  
NO.  
DESCRIPTION  
9
7
1
2
3
4
41A4202A  
10A14  
29C128  
Multi-function door control panel  
12V battery  
Transmitter visor clip  
Single-function remote control  
case, cover & screw only  
Manual release rope & handle assy.  
2-conductor bell wire, white & white/red  
Door bracket  
8
CEILING MOUNT ONLY  
UP  
41A3984-7  
5
6
7
8
9
41A2828  
217A238  
12B374-1  
12B380-1  
41A4353-1  
41A4373  
11  
10  
13  
Door bracket plate  
Header bracket w/clevis pin & fastener  
Safety sensor kit  
10  
(receiving and sending eye only)  
2-conductor bell wire with connector  
white & white/black (2 rolls)  
Curved door arm section  
Straight door arm section  
"C" wrap bracket  
14  
11  
41B4115  
12  
12  
13  
14  
15  
16  
178B35  
178B34  
12B483  
12B484  
12B485  
Square hole bracket  
Slotted bracket  
16  
15  
NOT SHOWN  
41A2770-1  
Installation hardware bag  
(includes hardware listed on page 5).  
41A4116  
Safety sensor hardware  
Owner's manual  
114A1857  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts  
Opener Assembly Parts  
1
2
4
9
7
3
5
6
8
8
10  
11  
20  
3
12  
18  
19  
9
13  
15  
5
17  
14  
(Down)  
Contact  
16  
LIMIT SWITCH ASSY.  
Brown  
Wire  
D N  
Grey  
Wire  
U P  
Drive  
Gear  
Center Limit  
Contact  
(Up)  
Contact  
Yellow  
Wire  
KEY PART  
KEY  
NO.  
PART  
NO.  
NO.  
NO.  
DESCRIPTION  
DESCRIPTION  
1
2
41A4371  
41A3587  
Belt cap retainer  
10  
11  
12  
13  
30B363  
12A373  
41A3150  
41D3058  
Capacitor - 1/2HP  
Capacitor bracket  
Gear and sprocket assembly  
Complete with:  
Spring washer  
Thrust washer  
Retaining ring  
Bearing plate  
Roll pins (2)  
Drive gear and worm gear  
Terminal block w/screws  
Universal replacement motor &  
bracket assembly  
Complete with: Motor, worm,  
bracket, bearing assembly, RPM  
sensor  
Helical gear w/retainer and grease  
14  
15  
16  
17  
18  
19  
20  
41A3583-3  
41A2818  
41D3452  
41C4398A  
41A2826  
41A2822A  
41A4416  
Cover  
3
41A2817  
Drive/worm gear kit w/grease  
Roll pins (2)  
Helical gear & retainer w/grease  
Limit switch assembly  
RPM sensor assembly  
Shaft bearing kit  
4
5
6
41B4245  
41C4253  
Line cord  
Wire harness assembly with plug  
41A4252-6B Receiver logic board assembly  
Complete with: Logic board,  
End panel w/all labels  
Interrupter cup assembly  
End panel  
NOT SHOWN  
7
8
9
41A4435  
175B88M  
108D34  
End panel w/all labels  
Light socket  
Lens  
41A2825  
Opener assembly hardware kit  
(includes screws not designated  
by a number in illustration).  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessories Available For Your Opener  
Model 1702LMC  
Model 60LMC  
Model 61LMC  
Model 81LMC  
Model 82LMC  
Single-Function Standard Size  
Remote Control:  
Outside Quick Release:  
Required for a garage with NO  
access door.  
Includes visor clip.  
Outside Keylock:  
"Smart" Remote Control:  
Opens the garage door automatically  
from outside when remote control is  
not handy.  
Includes visor clip.  
Model 1778LMC  
8 foot Complete Rail:  
2-Channel “Smart” Remote  
Control:  
To allow an 8 foot door to open fully.  
Includes visor clip.  
Model 1770LMC  
Model 66LMC  
10 foot Complete Rail:  
Model 83LMC  
Model 84LMC  
3-Channel “Smart” Remote  
Control:  
To allow a 10 foot door to open fully.  
Includes visor clip.  
Keyless Entry:  
4-Channel “Smart” Remote  
Control:  
Enables homeowner to operate  
garage door opener from outside  
by entering code on specially  
designed keyboard.  
Includes visor clip.  
Model 64LMC  
Model 58LMC  
Multi-Function Door Control Panel:  
Multi-Function Mini Remote  
Control:  
Provides a Lock Feature which  
prevents operation of garage door  
opener from portable remotes and a  
Light Feature for constant light.  
LOCK  
LIGHT  
With key ring & Velcro fastening  
strip.  
Model 99LMC  
Security Remote Control:  
E
N
T
E
R
Enables homeowner to operate garage door opener by entering 2, 3, 4, or 5 digit code from  
backlit keyboard. Includes visor clip.  
9
0
7
8
5
6
3
4
2
1
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Access Door/Outside Quick Release Accessory..........................................................................................4, 34  
Electrical Safety Warnings....................................................................................................................2, 7, 16, 27  
Garage Door  
Testing for balance, binding and sticking...................................................................................................3, 25, 27  
Determining high point of travel:  
Sectional Door ....................................................................................................................................................8  
One-Piece Door..............................................................................................................................................8, 9  
Disabling existing locks......................................................................................................................................3, 7  
Force Controls  
Adjustment Procedures ....................................................................................................................................25  
Problems that might require Force adjustments.........................................................................................30, 31  
Safety Warnings .........................................................................................................................................25, 27  
Door hardware.......................................................................................................................3, 7, 8, 12, 14, 27, 28  
Maintenance Instruction Label.........................................................................................................................7, 14  
Reinforcement requirements .....................................................................................................................4, 20, 21  
Removing of all ropes........................................................................................................................................3, 7  
Possible door damage...........................................................................................................................3, 4, 12, 20  
Travel Limits  
Adjustment Procedures ....................................................................................................................................24  
Problems that might require Limit adjustments...........................................................................................30, 31  
Safety Warnings ...................................................................................................................................15, 27, 28  
Manual Release Rope & Handle  
Lockout Feature..................................................................................................................................................28  
Manual Disconnect .......................................................................................................................................28, 31  
Safety Warnings ...........................................................................................................................................24, 27  
Opener Terminals  
Door Control Connections ..................................................................................................................................14  
Safety Reversing Sensor Connections...............................................................................................................19  
Outside Keylock Accessory Connections ...........................................................................................................14  
Protector System®..........................................................................................................................................17, 26  
Receiver and Remote Controls  
Programming the receiver ..................................................................................................................................29  
Erasing all codes ................................................................................................................................................29  
Safety warning....................................................................................................................................................29  
Problems with transmitter operation ...................................................................................................................30  
Safety Reverse Test Procedure..........................................................................................................................26  
Testing required..................................................................................................................................7, 26, 30, 31  
Safety Reverse System Problems  
Securing header bracket to wall .........................................................................................................................8  
Adjusting travel limits........................................................................................................................................24  
Applying excessive force on the door...............................................................................................................25  
Buckling or uneven floor ...............................................................................................................................4, 26  
Safety Warnings.......................................................2, 3, 6, 7, 8, 12, 13, 14, 15, 16, 17, 20, 24, 25, 26, 27, 28, 29  
User Instruction Label for garage wall ..........................................................................................................7, 14  
Vibration Noise (isolator kit)...............................................................................................................................30  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO ORDER  
REPAIR PARTS  
Selling prices will be furnished on request or parts will  
be shipped at prevailing prices and you will be billed  
accordingly.  
LIFT-MASTER SERVICE  
IS ON CALL  
OUR LARGE SERVICE ORGANIZATION  
SPANS AMERICA AND CANADA  
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE  
THE FOLLOWING INFORMATION:  
INSTALLATION AND SERVICE INFORMATION IS AS  
NEAR AS YOUR TELEPHONE SIX DAYS A WEEK.  
SIMPLY DIAL OUR TOLL FREE NUMBER:  
• PART NUMBER  
• PART NAME  
• MODEL NUMBER  
1-800-654-4736  
HOURS: (Mountain Std. Time)  
6:00 A.M. TO 6:00 P.M. - Monday through Friday  
7:00 A.M. TO 3:00 P.M. - Saturday  
Closed Sunday  
ADDRESS ORDERS TO:  
CHAMBERLAIN MFG., CANADA INC.  
230 Bayview Drive  
Barrie, Ont., Canada L4N 5E9  
For professional installation, parts and service,  
contact your local LIFT-MASTER/ CHAMBERLAIN  
dealer. Look for him in the Yellow Pages, or call our  
Service number for a list of dealers in your area.  
SERVICE INFORMATION  
TOLL FREE NUMBER:  
1-800-654-4736  
LIFT-MASTER GARAGE DOOR OPENER FIVE-YEAR LIMITED WARRANTY  
Chamberlain/Lift-Master warrants to the first retail purchaser of this product that it will be free from any defect in materials and/or  
workmanship for a period of 60 full months from the date of purchase. The product must be used in complete accordance with Lift-  
Master's instructions for installation, operation and care.  
This warranty does not cover non-defect damage, damage caused by unreasonable use (including abuse, failure to provide  
reasonable and necessary maintenance, or any alterations to the product), labor charges for dismantling or reinstalling of a repaired  
or replaced unit or replacement batteries.  
If, during the warranty period, the product appears as though it may be defective, CALL OUR TOLL FREE SERVICE NUMBER  
BEFORE DISMANTLING IT (1-800-654-4736). If the product is then alleged to be defective, please send it pre-paid and insured to  
our Service Center to obtain warranty repair. You will be advised of shipping instructions when you call the number listed above.  
Please be sure to include a brief description of the problem and a dated proof-of-purchase receipt with any product that is returned for  
warranty repair.  
Product under warranty, which upon receipt by Chamberlain/Lift-Master is determined to be defective in materials and/or  
workmanship, will be repaired or replaced (Chamberlain's option) at no cost to you and returned pre-paid. Defective parts will be  
repaired or replaced with new or factory rebuild parts at Chamberlain's option.  
THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS  
LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SOME PROVINCES MAY NOT ALLOW LIMITATIONS ON HOW  
LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.  
All claims for consequential or incidental damages for breach of this warranty are excluded and in no event shall manufacturer's  
liability for breach of warranty, negligence, strict liability or breach of contract exceed the cost of the product covered herein, but the  
purchaser is entitled to the remedies expressly provided in this policy. Some provinces do not allow the exclusion or limitation of  
incidental or consequential damages, so the above limitation or exclusion may not apply to you.  
No representative or person is authorized to assume for us any other liability in connection with the sale of this product. This warranty  
gives you specific legal rights, and you may also have other rights which may vary from province to province.  
© 1995, Chamberlain Mfg., Canada, Inc.  
114A1857B  
All Rights Reserved  
Printed in Mexico  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Saw 90521029 User Manual
BMW Car Video System CN1013887ID User Manual
Boston Acoustics Speaker MM226 User Manual
Bowens Camera Flash BWL 0335 2 User Manual
BOXLIGHT Projector CP 635i User Manual
Bravetti Oven K4930H User Manual
Campbell Hausfeld Nail Gun IFN102 User Manual
Canon Camera Flash 420EX User Manual
Carver Stereo Amplifier CV Series User Manual
Casio Musical Instrument LK 43 User Manual