Carrier Electric Heater 48P2 User Manual

WEATHERMASTER®  
48P2,P3,P4,P5030-100  
Single Package Gas Heating and Electric Cooling Units  
with Direct Spark Ignition and COMFORTLINK™ Controls  
Installation Instructions  
For additional information and service instructions, refer to  
the Controls and Troubleshooting literature.  
A factory-installed optional integral economizer and high-  
capacity power exhaust is available on size 075-100 units.  
A factory-installed optional return fan is available on size  
075-100 units.  
The staged gas control (SGC) option adds the capability to  
control the rooftop unit’s gas heating system to a specified  
supply-air temperature set point for purposes of tempering a  
cool mixed-air condition.  
CONTENTS  
Page  
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
SAFETY CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . .1,2  
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-68  
Step 1 — Jobsite Survey . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Step 2 — Place Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Step 3 — Roof Mount Unit. . . . . . . . . . . . . . . . . . . . . . . . 2  
Step 4 — Slab Mount Unit . . . . . . . . . . . . . . . . . . . . . . . . 2  
Step 5 — Install Curb Gasketing. . . . . . . . . . . . . . . . . . 2  
Step 6 — Install Field-Fabricated Ductwork . . . . . . 2  
Step 7 — Rig Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Step 8 — Connect Condensate Drain. . . . . . . . . . . . 16  
Step 9 — Install Outdoor Hoods (Units without  
Optional High-Capacity Power Exhaust). . . . . . 32  
• UNIT SIZES 030-050  
SAFETY CONSIDERATIONS  
Installation and servicing of air-conditioning equipment can  
be hazardous due to system pressure and electrical compo-  
nents. Only trained and qualified service personnel should  
install, repair, or service air-conditioning equipment.  
• UNIT SIZES 055-100  
Untrained personnel can perform basic maintenance func-  
tions of cleaning coils and filters and replacing filters. All  
other operations should be performed by trained service per-  
sonnel. When working on air-conditioning equipment, observe  
precautions in the literature, tags and labels attached to the unit,  
and other safety precautions that may apply.  
Follow all safety codes, including ANSI (American Nation-  
al Standards Institute) Z223.1. Wear safety glasses and work  
gloves. Use quenching cloth for unbrazing operations. Have  
fire extinguisher available for all brazing operations.  
Step 10 — Install Economizer Hoods (Units with  
Optional High-Capacity Power Exhaust). . . . . . 33  
• INSTALL SMALL HOODS  
• INSTALL LARGE HOODS  
Step 11 — Route Field Wiring . . . . . . . . . . . . . . . . . . . 35  
• UNIT SIZES 030-060  
• UNIT SIZES 070-100  
Step 12 — Make Field Electrical Connections . . . 35  
• POWER WIRING  
Step 13 — Connect Air Pressure Tubing . . . . . . . . 58  
VARIABLE FRQUENCY DRIVE  
• MODULATING POWER EXHAUST  
• RETURN FAN POWER EXHAUST  
WARNING  
Step 14 — Remove Supply-Fan Shipping  
Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60  
Step 15 — Remove Optional Return-Fan  
Shipping Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . 60  
Step 16 — Connect Gas Piping. . . . . . . . . . . . . . . . . . 61  
Step 17 — Configure Optional Staged Gas  
Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61  
Step 18 — Install Flue/Inlet Hoods and Baffles . . 62  
Step 19 — Install Supply-Air Thermistors  
(Staged and Modulating Gas Units Only) . . . . . 62  
Step 20 — Install Optional Motormaster® V  
Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66  
Step 21 — Install Unit Accessories. . . . . . . . . . . . . . 68  
Before performing service or maintenance operations on  
unit, turn off main power switch to unit. Electrical shock  
could cause personal injury.  
FOR YOUR SAFETY  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any appliance. Do not touch any electri-  
cal switch; do not use any phone in your building. Immedi-  
ately call your gas supplier from a neighbor’s phone.  
Follow the gas supplier’s instructions. If you cannot reach  
your gas supplier, call the fire department.  
CONTROLS INSTALLATION . . . . . . . . . . . . . . . . . . 68-76  
Constant Volume Units. . . . . . . . . . . . . . . . . . . . . . . . . . 68  
• CONTROL WIRING  
Variable Air Volume (VAV) Units . . . . . . . . . . . . . . . . . 68  
Optional and Accessory Control Wiring . . . . . . . . . 68  
Carrier Comfort Network® (CCN) Interface. . . . . . . 73  
Optional UPC Open Installation . . . . . . . . . . . . . . . . . 74  
Smoke Control Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . 74  
FOR YOUR SAFETY  
Do not store or use gasoline or other flammable vapors and  
liquids in the vicinity of this or any other appliance.  
WARNING  
Improper installation, adjustment, alteration, service, or  
maintenance can cause injury or property damage. Refer to  
this manual. For assistance or additional information, con-  
sult a qualified installer, service agency, or the gas supplier.  
GENERAL  
This installation instruction contains basic unit installation  
information, including installation of thermostats and remote  
temperature sensors.  
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.  
Catalog No. 04-53480079-01 Printed in U.S.A. Form 48P-4SI Pg 1 11-10 Replaces: 48P-3SI  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1A — Physical Data 48P2,P3,P4,P5030-050  
BASE UNIT  
48P2,P3,P4,P5030  
48P2,P3,P4,P5035  
NOMINAL CAPACITY (tons)  
30  
35  
OPERATING WEIGHT (lb)  
Base Unit  
Standard Chassis  
Extended Chassis  
Standard Chassis  
Extended Chassis  
Low Heat  
5310  
5440  
5810  
5940  
5410  
5540  
5910  
6040  
High Heat  
With Economizer  
Low Heat  
5610  
5740  
6110  
6240  
5710  
5840  
6210  
6340  
High Heat  
COMPRESSORS  
Scroll  
Quantity...Type  
1...ZP154/1...ZP154  
1...ZP182/1...ZP182  
Oil Charge (oz) per Compressor  
Number of Refrigerant Circuits  
110  
2
110  
2
REFRIGERANT  
R-410A  
Operating Charge (lb), Ckt 1/Ckt 2  
Standard Evaporator Coil  
15.4/14.8  
15.4/24.9  
18.4/17.7  
18.4/27.8  
18.4/17.6  
18.4/27.7  
N/A  
Standard Evaporator with Humidi-MiZer®  
Alternate High-Capacity Evaporator Coil  
Alternate High-Capacity Evaporator with Humidi-MiZer  
N/A  
CONDENSER COILS  
Quantity  
Total Face Area (sq ft)  
Aluminum Novation® Heat Exchanger with Microchannel Coils  
1
1
33.3  
33.3  
EVAPORATOR COILS  
Quantity  
1
Total Face Area (sq ft)  
Refrigerant Feed Device...No. per Circuit  
Standard Evaporator Coils  
Rows...Fins/in.  
32.1  
TXV...1  
3...15.0  
4...15.0  
Double Wavy  
Cross Hatched  
Fin Type  
Tube Type  
Double Wavy  
Cross Hatched  
Alternate, High-Capacity Evaporator Coils  
Rows...Fins/in.  
4...15.0  
Double Wavy  
Cross Hatched  
N/A  
N/A  
N/A  
Fin Type  
Tube Type  
HEATING SECTION  
Low Heat  
7
High Heat  
14  
Low Heat  
7
High Heat  
14  
Number of Heat Exchangers  
Input (MBtuh)  
325  
650  
325  
650  
Output (MBtuh) (Vertical/Horizontal)  
Temperature Rise Range (F)  
Efficiency (%) (Vertical/Horizontal)  
Burner Orifice Diameter  
Quantity (in. ...drill no.)  
Manifold Pressure (in. wg)  
Line Pressure (in. wg) (min...max)  
Firing Stages  
263/260  
10-40  
81/80  
527/520  
25-55  
81/80  
263/260  
10-40  
81/80  
527/520  
25-55  
81/80  
7 (.1285...30)  
14 (.1285...30)  
7 (.1258...30)  
14 (.1258...30)  
3.5  
3.5  
3.5  
3.5  
5.0...13.0  
5.0...13.0  
5.0...13.0  
5.0...13.0  
2
1
2
2
2
1
2
2
Number of Gas Valves  
CONDENSER FANS  
Quantity...Diameter (in.)  
Nominal Cfm  
Propeller Type  
2...30  
18,000  
1.0...1140  
2...30  
19,500  
1.0...1140  
Motor Hp...Rpm  
SUPPLY FAN  
Centrifugal 25 x 25 in.  
Nominal Cfm  
10,500  
15,000  
900  
10,500  
15,000  
900  
Maximum Allowable Cfm  
Maximum Allowable Rpm  
Shaft Diameter at Pulley (in.)  
111  
/
111/  
16  
16  
SUPPLY-FAN MOTOR AND DRIVE  
Motor Hp  
(Any motor available on any unit)  
15  
7.5  
10  
215T  
20  
25  
Motor Frame Size  
213T  
254T  
256T  
284T  
Efficiency at Full Load (%)  
High Efficiency  
Premium Efficiency  
88.5  
91.7  
89.5  
91.7  
91.0  
93.0  
91.0  
93.6  
13.7  
5.5  
91.7  
93.6  
Fan Pulley Pitch Diameter (in.)  
Motor Pulley Pitch Diameter (in.)  
Resulting Fan Speed (rpm)  
Belts Quantity...Type  
13.7  
13.7  
13.7  
13.7  
3.4  
4.3  
549  
4.9  
626  
6.5  
438  
703  
830  
2...BX60  
17.74-14.30  
2...5VX630  
17.74-14.30  
2...5VX630  
17.63...14.01  
2...5VX630  
2...5VX650  
16.63...12.87  
Center Distance Range (in.)  
17.63...14.01  
OPTIONAL POWER EXHAUST†  
Quantity...Motor Hp  
Centrifugal, 18 x 15 in. (Any motor available on any unit)  
2...3.0  
56HZ  
182T  
81.0/88.5  
11  
2...5.0  
184T  
2...7.5  
213T  
213T  
88.5/91.7  
12  
2...10  
215T  
215T  
89.5/91.7  
12  
Motor Frame Size  
High Eff  
Prem Eff  
184T  
Efficiency at Full Load (%) High/Premium  
Fan Pulley Pitch Diameter (in.)  
87.5/89.5  
10.4  
High Eff  
Prem Eff  
High Eff  
Prem Eff  
11.0  
10.4  
12  
12  
Motor Pulley Pitch Diameter Range (in.)  
4.1-3.1  
4.1-3.1  
4.1  
4.7-3.7  
4.7-3.7  
4.2  
6.0-4.8  
6.0-4.8  
5.4  
7.0-5.8  
7.0-5.8  
6.4  
Motor Pulley Pitch Diameter Factory Setup (in.)  
Blower Shaft Diameter at Pulley (in.)  
Fan Rpm Range  
Factory Setup Fan Rpm  
Maximum Allowable Rpm  
17/16  
17/16  
17/16  
17/16  
500-656  
656  
621-785  
703  
1000  
717-882  
800  
1000  
854-1000  
927  
1000  
1000  
FILTERS  
Standard Efficiency Throwaway (Standard)  
Quantity...Size (in.)  
8...20 x 25 x 2, 8...20 x 20 x 2  
8...20 x 25 x 2, 8...20 x 20 x 2  
8...20 x 25 x 2, 8...20 x 20 x 2  
Medium Efficiency (30%) Pleated (Optional)  
Quantity...Size (in.)  
8...20 x 25 x 2, 8...20 x 20 x 2  
High Efficiency (90%) Bag Filters  
with High Velocity Prefilters (Opt)  
Quantity...Size (in.)  
Bag Filter  
Prefilter  
6...20 x 24 x 22, 6...20 x 20 x 22  
12...16 x 20 x 2, 3...20 x 24 x 2  
6...20 x 24 x 22, 6...20 x 20 x 22  
12...16 x 20 x 2, 3...20 x 24 x 2  
MERV 15 Cartridge Filters with High Velocity Prefilters (Opt)  
Quantity...Size (in.)  
Cartridge Filter  
Prefilter  
6...20 x 24 x 12, 6...20 x 20 x 12  
12...16 x 20 x 2, 3...20 x 24 x 2  
6...20 x 24 x 12, 6...20 x 20 x 12  
12...16 x 20 x 2, 3...20 x 24 x 2  
OUTSIDE AIR SCREENS  
Standard Hood (25%) Quantity...Size (in.)  
None  
None  
OPTIONAL ECONOMIZER FILTER  
Quantity...Size (in.)  
Aluminum Frame, Permanent  
5...20 x 20 x 2  
2...20 x 25 x 1  
5...20 x 20 x 1  
2...20 x 25 x 1  
LEGEND  
* 460-3-60 only.  
MBtuh  
TXV  
Btuh in Thousands  
Thermostatic Expansion Valve  
†See Table 7 — Power Exhaust Fan Drive Data on page 9 for more information.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1A — Physical Data 48P2,P3,P4,P5030-050 (cont)  
BASE UNIT  
48P2,P3,P4,P5040  
48P2,P3,P4,P5050  
NOMINAL CAPACITY (tons)  
40  
50  
OPERATING WEIGHT (lb)  
Base Unit  
Standard Chassis  
Extended Chassis  
Standard Chassis  
Extended Chassis  
Low Heat  
5810  
5940  
6310  
6440  
6025  
6155  
6525  
6655  
High Heat  
With Economizer  
Low Heat  
6110  
6240  
6610  
6740  
6325  
6455  
6825  
6955  
High Heat  
COMPRESSORS  
Scroll  
Quantity...Type  
2...ZP103/1...ZP182  
2...ZP120/2...ZP137  
Oil Charge (oz) per Compressor  
Number of Refrigerant Circuits  
110  
2
110  
2
REFRIGERANT  
R-410A  
Operating Charge (lb), Ckt 1/Ckt 2  
Standard Evaporator Coil  
21.6/26.7  
21.6/39.1  
35.1/37.2  
31.1/49.6  
29.4/29.0  
29.4/41.4  
38.2/36.5  
38.2/48.9  
Standard Evaporator with Humidi-MiZer®  
Alternate High-Capacity Evaporator Coil  
Alternate High-Capacity Evaporator with Humidi-MiZer  
CONDENSER COILS  
Quantity  
Total Face Area (sq ft)  
Aluminum Novation® Heat Exchanger with Microchannel Coils  
2
2
66.7  
66.7  
EVAPORATOR COILS  
Quantity  
1
Total Face Area (sq ft)  
Refrigerant Feed Device...No. per Circuit  
Standard Evaporator Coils  
Rows...Fins/in.  
45.5  
TXV...2  
3...15.0  
4...15.0  
Double Wavy  
Cross Hatched  
Fin Type  
Tube Type  
Double Wavy  
Cross Hatched  
Alternate, High-Capacity Evaporator Coils  
Rows...Fins/in.  
6...16.0  
Double Wavy  
Cross Hatched  
6...16.0  
Double Wavy  
Cross Hatched  
Fin Type  
Tube Type  
HEATING SECTION  
Low Heat  
7
High Heat  
14  
Low Heat  
7
High Heat  
14  
Number of Heat Exchangers  
Input (MBtuh)  
325  
650  
325  
650  
Output (MBtuh) (Vertical/Horizontal)  
Temperature Rise Range (F)  
Efficiency (%) (Vertical/Horizontal)  
Burner Orifice Diameter  
Quantity (in. ...drill no.)  
Manifold Pressure (in. wg)  
Line Pressure (in. wg) (min...max)  
Firing Stages  
263/260  
10-40  
81/80  
527/520  
25-55  
81/80  
263/260  
10-40  
81/80  
527/520  
25-55  
81/80  
7 (.1285...30)  
14 (.1285...30)  
7 (.1285...30)  
14 (.1285...30)  
3.5  
3.5  
3.5  
3.5  
5.0...13.0  
5.0...13.0  
5.0...13.0  
5.0...13.0  
2
1
2
2
2
1
2
2
Number of Gas Valves  
CONDENSER FANS  
Quantity...Diameter (in.)  
Nominal Cfm  
Propeller Type  
3...30  
30,000  
1.0...1140  
4...30  
38,000  
1.0...1140  
Motor Hp...Rpm  
SUPPLY FAN  
Centrifugal 25 x 25 in.  
Nominal Cfm  
14,000  
20,000  
900  
14,000  
20,000  
900  
Maximum Allowable Cfm  
Maximum Allowable Rpm  
Shaft Diameter at Pulley (in.)  
111  
/
111/  
16  
16  
SUPPLY-FAN MOTOR AND DRIVE  
Motor Hp  
(Any motor available on any unit)  
7.5  
10  
15  
20  
25  
30*  
Motor Frame Size  
213T  
215T  
254T  
256T  
284T  
286T  
Efficiency at Full Load (%)  
High Efficiency  
Premium Efficiency  
88.5  
91.7  
89.5  
91.7  
91.0  
93.0  
91.0  
93.6  
91.7  
93.6  
13.7  
6.5  
92.4  
93.6  
Fan Pulley Pitch Diameter (in.)  
Motor Pulley Pitch Diameter (in.)  
Resulting Fan Speed (rpm)  
Belts Quantity...Type  
13.7  
13.7  
13.7  
13.7  
12.5  
3.4  
4.3  
4.9  
626  
5.5  
703  
6.5  
438  
549  
830  
910  
2...BX60  
17.74-14.30  
2...5VX630  
17.74-14.30  
2...5VX630  
17.63...14.01  
2...5VX630  
17.63...14.01  
2...5VX650  
3...5VX630  
16.63...12.87  
Center Distance Range (in.)  
16.63...12.87  
OPTIONAL POWER EXHAUST†  
Quantity...Motor Hp  
Centrifugal, 18 x 15 in. (Any motor available on any unit)  
2...3.0  
56HZ  
182T  
81.0/88.5  
11  
2...5.0  
184T  
2...7.5  
213T  
213T  
88.5/91.7  
12  
2...10  
215T  
215T  
89.5/91.7  
12  
Motor Frame Size  
High Eff  
Prem Eff  
184T  
Efficiency at Full Load (%) High/Premium  
Fan Pulley Pitch Diameter (in.)  
87.5/89.5  
10.4  
High Eff  
Prem Eff  
High Eff  
Prem Eff  
11.0  
10.4  
12  
12  
Motor Pulley Pitch Diameter Range (in.)  
4.1-3.1  
4.1-3.1  
4.1  
4.7-3.7  
4.7-3.7  
4.2  
6.0-4.8  
6.0-4.8  
5.4  
7.0-5.8  
7.0-5.8  
6.4  
Motor Pulley Pitch Diameter Factory Setup (in.)  
Blower Shaft Diameter at Pulley (in.)  
Fan Rpm Range  
Factory Setup Fan Rpm  
Maximum Allowable Rpm  
17/16  
17/16  
17/16  
17/16  
500-656  
656  
621-785  
703  
1000  
717-882  
800  
1000  
854-1000  
927  
1000  
1000  
FILTERS  
Standard Efficiency Throwaway (Standard)  
Quantity...Size (in.)  
8...20 x 25 x 2, 8...20 x 20 x 2  
8...20 x 25 x 2, 8...20 x 20 x 2  
Medium Efficiency (30%) Pleated (Optional)  
Quantity...Size (in.)  
8...20 x 25 x 2, 8...20 x 20 x 2  
8...20 x 25 x 2, 8...20 x 20 x 2  
High Efficiency (90%) Bag Filters  
with High Velocity Prefilters (Opt)  
Quantity...Size (in.)  
Bag Filter  
Prefilter  
6...20 x 24 x 22, 6...20 x 20 x 22  
12...16 x 20 x 2, 3...20 x 24 x 2  
6...20 x 24 x 22, 6...20 x 20 x 22  
12...16 x 20 x 2, 3...20 x 24 x 2  
MERV 15 Cartridge Filters with High Velocity Prefilters (Opt)  
Quantity...Size (in.)  
Cartridge Filter  
Prefilter  
6...20 x 24 x 12, 6...20 x 20 x 12  
12...16 x 20 x 2, 3...20 x 24 x 2  
6...20 x 24 x 12, 6...20 x 20 x 12  
12...16 x 20 x 2, 3...20 x 24 x 2  
OUTSIDE AIR SCREENS  
Standard Hood (25%) Quantity...Size (in.)  
None  
None  
OPTIONAL ECONOMIZER FILTER  
Quantity...Size (in.)  
Aluminum Frame, Permanent  
5...20 x 20 x 2  
2...20 x 25 x 1  
5...20 x 20 x 1  
2...20 x 25 x 1  
LEGEND  
* 460-3-60 only.  
MBtuh  
TXV  
Btuh in Thousands  
Thermostatic Expansion Valve  
†See Table 7 — Power Exhaust Fan Drive Data on page 9 for more information.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1B — Physical Data 48P2,P3,P4,P5055-070  
BASE UNIT  
48P2,P3,P4,P5055  
48P2,P3,P4,P5060  
48P2,P3,P4,P5070  
NOMINAL CAPACITY (tons)  
55  
60  
70  
OPERATING WEIGHT (lb)  
Base Unit  
Standard Chassis  
Extended Chassis  
Standard Chassis  
Extended Chassis  
Standard Chassis  
Extended Chassis  
Low Heat  
7810  
7940  
8360  
8490  
7865  
7995  
8415  
8545  
8205  
8335  
8755  
8885  
High Heat  
With Economizer  
Low Heat  
8340  
8470  
8890  
9020  
8395  
8525  
8945  
9075  
8735  
8865  
9285  
9415  
High Heat  
COMPRESSORS  
Scroll  
Quantity...Type  
2...ZP137/2...ZP137  
2...ZP154/2...ZP154  
1...ZP54,1...ZP182/1...ZP54,1...ZP182  
Oil Charge (oz) per Compressor  
Number of Refrigerant Circuits  
110  
2
110  
2
110  
2
REFRIGERANT  
R-410A  
Operating Charge (lb), Ckt 1/Ckt 2  
Standard Evaporator Coil  
37.6/37.9  
37.6/50.3  
46.5/45.8  
46.5/58.2  
42.2/41.8  
42.2/54.2  
47.6/46.5  
47.6/58.9  
43.5/44.8  
43.5/57.2  
55.4/55.5  
55.4/67.9  
Standard Evaporator with Humidi-MiZer®  
Alternate High-Capacity Evaporator Coil  
Alternate High-Capacity Evaporator with  
Humidi-MiZer  
CONDENSER COILS  
Quantity  
Total Face Area (sq ft)  
Aluminum Novation® Heat Exchanger with Microchannel Coils  
2
66.7  
2
4
66.7  
106.7  
EVAPORATOR COILS  
Quantity  
2
Total Face Area (sq ft)  
Refrigerant Feed Device...No. per Circuit  
Standard Evaporator Coils  
Rows...Fins/in.  
61.5  
TXV...2  
4...15  
4...15  
Double Wavy  
Cross Hatched  
4...15  
Double Wavy  
Cross Hatched  
Fin Type  
Tube Type  
Double Wavy  
Cross Hatched  
Alternate, High-Capacity Evaporator Coils  
Rows...Fins/in.  
6...16  
Double Wavy  
Cross Hatched  
6...16  
Double Wavy  
Cross Hatched  
6...16  
Double Wavy  
Cross Hatched  
Fin Type  
Tube Type  
HEATING SECTION  
Low Heat  
High Heat  
21  
Low Heat  
14  
High Heat  
21  
Low Heat  
High Heat  
21  
Number of Heat Exchangers  
Input (MBtuh)  
14  
650  
14  
650  
975  
650  
975  
975  
Output (MBtuh) (Vertical/Horizontal)  
Temperature Rise Range (F)  
Efficiency (%) (Vertical/Horizontal)  
Burner Orifice Diameter  
Quantity (in. ...drill no.)  
Manifold Pressure (in. wg)  
Line Pressure (in. wg) (min...max)  
Firing Stages  
527/520  
10-40  
81/80  
790/780  
20-50  
81/80  
527/520  
10-40  
81/80  
790/780  
20-50  
81/80  
527/520  
10-40  
81/80  
790/780  
20-50  
81/80  
14 (.1285...30)  
21 (.1285...30)  
14 (.1285...30)  
21 (.1285...30)  
14 (.1285...30)  
21 (.1285...30)  
3.5  
3.5  
3.5  
3.5  
3.5  
3.5  
5.0...13.0  
5.0...13.0  
5.0...13.0  
5.0...13.0  
5.0...13.0  
5.0...13.0  
2
2
2
3
2
2
2
3
2
2
2
3
Number of Gas Valves  
CONDENSER FANS  
Quantity...Diameter (in.)  
Nominal Cfm  
Propeller Type  
4...30  
4...30  
36,600  
4...30  
36,000  
39,000  
Motor Hp...Rpm  
1.0...1140  
1.0...1140  
1.0...1140  
SUPPLY FAN  
Centrifugal 30 x 27.5 in.  
Nominal Cfm  
17,500  
25,000  
800  
21,000  
30,000  
800  
24,500  
30,000  
800  
Maximum Allowable Cfm  
Maximum Allowable Rpm  
Shaft Diameter at Pulley (in.)  
111  
/
111  
/
111/  
16  
16  
16  
SUPPLY-FAN MOTOR AND DRIVE  
Motor Hp  
(Any motor available on any unit)  
15  
20  
25  
30  
40†  
Motor Frame Size  
254T  
256T  
284T  
286T  
S324T  
Efficiency at Full Load (%)  
High Efficiency  
Premium Efficiency  
91.0  
93.0  
91.0  
93.6  
91.7  
93.6  
92.4  
93.6  
93.0  
94.5  
Fan Pulley Pitch Diameter (in.)  
Motor Pulley Pitch Diameter (in.)  
Resulting Fan Speed (rpm)  
Belts Quantity...Type  
13.7  
13.7  
13.7  
15.5  
16.1  
4.5  
5.1  
651  
5.5  
703  
5.9  
6.7  
575  
711  
740  
2...5VX1230  
48.25-44.00  
2...5VX1230  
48.25-44.00  
2...5VX1230  
48.50-44.25  
2...5VX1230  
48.50-44.25  
3...5VX1250  
48.25-44.00  
Center Distance Range (in.)  
OPTIONAL POWER EXHAUST*  
Quantity...Motor Hp  
Centrifugal, 18 x 15 in. (Any motor available on any unit)  
2...5  
184T  
2...7.5  
213T  
2...10  
215T  
Motor Frame Size  
Efficiency at Full Load (%) High/Premium  
Resulting Fan Rpm  
Maximum Allowable Rpm  
87.5/89.5  
740  
88.5/91.7  
820  
1000  
89.5/91.7  
920  
1000  
1000  
FILTERS  
Standard Efficiency Throwaway (Standard)  
Quantity...Size (in.)  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
Medium Efficiency (30%) Pleated (Optional)  
Quantity...Size (in.)  
High Efficiency (90%) Bag Filters  
with High Velocity Prefilters (Optional)  
Quantity...Size (in.)  
Bag Filter  
Prefilter  
6...24 x 24 x 22, 6...24 x 20 x 22  
6...24 x 24 x 2, 6...20 x 24 x 2  
6...24 x 24 x 22, 6...24 x 20 x 22  
6...24 x 24 x 2, 6...20 x 24 x 2  
6...24 x 24 x 22, 6...24 x 20 x 22  
6...24 x 24 x 2, 6...20 x 24 x 2  
MERV 15 Cartridge Filters with  
High Velocity Prefilters (Optional)  
Quantity...Size (in.)  
Cartridge Filter  
Prefilter  
6...24 x 24 x 12,, 6...24 x 20 x 12  
6...24 x 24 x 2, 6...20 x 24 x 2  
6...24 x 24 x 12,, 6...24 x 20 x 12  
6...24 x 24 x 2, 6...20 x 24 x 2  
6...24 x 24 x 12, 6...24 x 20 x 12  
6...24 x 24 x 2, 6...20 x 24 x 2  
OUTSIDE AIR SCREENS  
Standard Hood (25%) Quantity...Size (in.)  
4...25 x 16 x 1, 2...20 x 16 x 1  
12...16 x 25 x 1, 2...16 x 20 x 1  
4...25 x 16 x 1, 2...20 x 16 x 1  
4...25 x 16 x 1, 2...20 x 16 x 1  
12...16 x 25 x 1, 2...16 x 20 x 1  
OPTIONAL ECONOMIZER FILTER  
Quantity...Size (in.)  
Aluminum Frame, Permanent  
12...16 x 25 x 1, 2...16 x 20 x 1  
LEGEND  
*See Table 7 — Power Exhaust Fan Drive Data on page 9 for more information.  
MBtuh  
TXV  
Btuh in Thousands  
Thermostatic Expansion Valve  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1C — Physical Data 48P2,P3,P4,P5075-100  
BASE UNIT  
48P2,P3,P4,P5075  
48P2,P3,P4,P5090  
48P2,P3,P4,P5100  
NOMINAL CAPACITY (tons)  
OPERATING WEIGHT (lb)  
75  
90  
100  
Standard  
Extended  
Chassis  
Standard  
Extended  
Chassis  
Standard  
Extended  
Chassis  
Chassis  
Chassis  
Chassis  
Base Unit  
Low Heat  
9065  
9195  
9615  
9745  
9665  
9795  
10,215  
10,345  
9685  
9815  
10,235  
10,365  
High Heat  
With Economizer  
Low Heat  
9595  
9725  
10,145  
10,275  
10,195  
10,325  
10,745  
10,875  
10,215  
10,345  
10,765  
10,895  
High Heat  
COMPRESSORS  
Scroll  
Quantity...Type  
2...ZP82/2...ZP182  
3...ZP154,3...ZP154  
3...ZP154,3...ZP182  
Oil Charge (oz) per Compressor  
Number of Refrigerant Circuits  
110  
2
110  
2
110  
2
REFRIGERANT  
R-410A  
Operating Charge (lb), Ckt 1/Ckt 2  
Standard Evaporator Coil  
43.8/45.0  
43.8/57.4  
55.1/54.9  
55.1/67.3  
50.4/51.3  
50.4/69.1  
61.5/62.9  
61.5/80.7  
50.8/52.8  
50.8/70.6  
59.3/62.8  
59.3/80.6  
Standard Evaporator with Humidi-MiZer®  
Alternate High-Capacity Evaporator Coil  
Alternate High-Capacity Evaporator with  
Humidi-MiZer  
CONDENSER COILS  
Quantity  
Aluminum Novation® Heat Exchanger with Microchannel Coils  
4
6
6
Total Face Area (sq ft)  
106.7  
160.0  
160.0  
EVAPORATOR COILS  
Quantity  
2
Total Face Area (sq ft)  
Refrigerant Feed Device...No. per Circuit  
Standard Evaporator Coils  
Rows...Fins/in.  
61.5  
TXV...2  
4...15  
4...15  
4...15  
Double Wavy  
Cross Hatched  
Fin Type  
Tube Type  
Double Wavy  
Double Wavy  
Cross Hatched  
Cross Hatched  
Alternate, High-Capacity Evaporator Coils  
Rows...Fins/in.  
6...16  
Double Wavy  
Cross Hatched  
6...16  
Double Wavy  
Cross Hatched  
6...16  
Double Wavy  
Cross Hatched  
Fin Type  
Tube Type  
HEATING SECTION  
Low Heat  
High Heat  
3
Low Heat  
High Heat  
3
Low Heat  
High Heat  
3
Number of Heat Exchangers  
Input (MBtuh)  
2
2
2
650  
975  
650  
975  
650  
975  
Output (MBtuh) (Vertical/Horizontal)  
Temperature Rise Range (F)  
Efficiency (%) (Vertical/Horizontal)  
Burner Orifice Diameter  
527/520  
10-40  
81/80  
790/780  
20-50  
81/80  
527/520  
10-40  
81/80  
790/780  
20-50  
81/80  
527/520  
10-40  
81/80  
790/780  
20-50  
81/80  
Quantity (in. ...drill no.)  
7 (.1285...30)  
7 (.1285...30)  
7 (.1285...30)  
7 (.1285...30)  
7 (.1285...30)  
7 (.1285...30)  
Manifold Pressure (in. wg)  
Line Pressure (in. wg) (Min...Max)  
Number of Gas Valves  
3.5  
5.0...13.0  
2
3.5  
5.0...13.0  
3
3.5  
5.0...13.0  
2
3.5  
5.0...13.0  
3
3.5  
5.0...13.0  
2
3.5  
5.0...13.0  
3
CONDENSER FAN  
Quantity...Diameter (in.)  
Nominal Cfm  
Propeller Type  
4...30  
6...30  
58,000  
6...30  
39,000  
58,000  
Motor Hp (ea)...rpm  
1.0...1140  
1.0...1140  
1.0...1140  
STANDARD SUPPLY FAN  
Nominal Cfm  
Maximum Allowable Cfm  
Maximum Allowable Rpm  
Shaft Diameter at Pulley (in.)  
Forward Curved Centrifugal 36 x 30 in.  
24,500  
30,000  
680  
29,750  
34,000  
680  
35,000  
40,000  
680  
111  
/
111  
/
16  
111  
/
16  
16  
STANDARD SUPPLY-FAN MOTOR AND DRIVE  
Motor Hp  
(Any motor available on any unit)  
30  
40  
50  
60  
Motor Frame Size  
S268T  
S324T  
S36T  
S364T  
Efficiency at Full Load (%)  
High Efficiency  
Premium Efficiency  
92.4  
93.6  
93.0  
94.5  
93.0  
94.5  
93.6  
95.4  
18.5  
7.1  
Fan Pulley Pitch Diameter (in.)  
Motor Pulley Pitch Diameter (in.)  
Resulting Fan Rpm  
18.5  
18.5  
18.5  
5.3  
5.7  
539  
6.5  
615  
501  
672  
4...5VX1320  
47.42-44.52  
Belts Quantity...Type  
Center Distance Range (in.)  
3...5VX1320  
47.88-45.01  
4...5VX1320  
47.64-44.76  
4...5VX1320  
47.42-44.52  
ALTERNATE, AIRFOIL FAN  
Airfoil  
29,750  
34,000  
1846  
Nominal Airflow (cfm)  
24,500  
30,000  
1846  
35,000  
40,000  
1846  
Maximum Allowable Airflow (cfm)  
Maximum Allowable Wheel Speed (rpm)  
Shaft Diameter at Pulley (in.)  
211  
/
211  
/
16  
211  
/
16  
16  
ALTERNATE SUPPLY-FAN MOTOR AND DRIVE  
Motor Hp  
(Any motor available on any unit)  
50  
30  
40  
60  
75  
Motor Frame Size  
S268T  
S324T  
S36T  
S364T  
365T  
Efficiency at Full Load (%)  
High Efficiency  
Premium Efficiency  
92.4  
93.6  
93.0  
94.5  
93.0  
94.5  
8.9  
93.6  
95.4  
94.1  
95.4  
Fan Pulley Pitch Diameter (in.)  
Motor Pulley Pitch Diameter (in.)  
Resulting Fan Rpm  
9.7  
10.2  
8.9  
10.8  
7.5  
8.7  
8.1  
1593  
8.7  
11.1  
1353  
1493  
1711  
1799  
Belts Quantity...Type  
Center Distance Range (in.)  
2...5VX1150  
42.96...45.82  
2...5VX1180  
42.96...45.57  
3...5VX1150  
42.96...45.57  
3...5VX1150  
42.45...45.35  
3...5VX1230  
42.45...45.35  
LEGEND  
*See Table 3 — High-Capacity Power Exhaust Data for more information. See  
Table 7 — Power Exhaust Fan Drive Data on page 9 for more information.  
MBtuh — Btuh in Thousands  
TXV  
Thermostatic Expansion Valve  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1C — Physical Data 48P2,P3,P4,P5075-100 (cont)  
BASE UNIT  
48P2,P3,P4,P5075  
48P2,P3,P4,P5090  
48P2,P3,P4,P5100  
OPTIONAL POWER EXHAUST*  
Quantity...Motor Hp  
Centrifugal, 18 x 15 in. (Any motor available on any unit.)  
2...5  
2...7.5  
213T  
2...10  
215T  
Motor Frame Size  
184T  
Efficiency at Full Load (%)  
High Efficiency  
Premium Efficiency  
87.5  
89.5  
10.6  
4.5  
88.5  
91.7  
10.6  
5.0  
89.5  
91.7  
10.6  
5.6  
Fan Pulley Pitch Diameter (in.)  
Motor Pulley Pitch Diameter (in.)  
Shaft Diameter at Pulley (in.)  
Resulting Fan Rpm  
17/16  
740  
17/16  
820  
17/16  
920  
Maximum Allowable Rpm  
1000  
1000  
1000  
FILTERS  
Standard Efficiency Throwaway  
(Standard)  
Quantity...Size (in.)  
30% and 65% Pleated (Optional)  
Quantity...Size (in.)  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
12...20 x 25 x 2, 12...20 x 20 x 2  
OUTSIDE AIR SCREENS  
Standard Hood (25%) Quantity...Size (in.)  
4...25 x 16 x 1, 2...20 x 16 x 1  
12...16 x 25 x 1, 2...16 x 20 x 1  
4...25 x 16 x 1, 2...20 x 16 x 1  
4...25 x 16 x 1, 2...20 x 16 x 1  
12...16 x 25 x 1, 2...16 x 20 x 1  
OPTIONAL ECONOMIZER FILTER  
Quantity...Size (in.)  
Aluminum Frame, Permanent  
12...16 x 25 x 1, 2...16 x 20 x 1  
LEGEND  
*See Table 3 — High-Capacity Power Exhaust Data for more information. See  
Table 7 — Power Exhaust Fan Drive Data on page 9 for more information.  
MBtuh — Btuh in Thousands  
TXV  
Thermostatic Expansion Valve  
Table 2 — Optional Return Fan Physical Data (48P075-100 Only)  
BASE UNIT  
48P2,P3,P4,P5075-100  
RETURN FAN  
Plenum Fan, 47.13 in. (Any motor available on any unit.)  
1...25 1...30  
284T 286T  
Quantity...Motor Hp  
1...20  
256T  
1...40  
324T  
Motor Frame Size  
Efficiency at Full Load (%) High/Premium  
Fan Pulley Pitch Diameter (in.)  
Motor Pulley Pitch Diameter (in.)  
Shaft Diameter at Pulley (in.)  
Resulting Fan Rpm  
91.0/93.6  
8.5  
91.7/93.6  
9.8  
92.4/93.6  
8.5  
93.0/93.8  
8.5  
5.3  
6.7  
6.1  
6.7  
215  
/
215  
/
215  
/
215  
/
16  
16  
16  
16  
1104  
1447  
1209  
1447  
1271  
1447  
1396  
1447  
Maximum Allowable Rpm  
Table 3 — Optional High-Capacity Power Exhaust Physical Data (48P075-100 Only)  
BASE UNIT  
48P2,P3,P4,P5075-100  
POWER EXHAUST  
Centrifugal, 22 x 20 in., 111  
/16 in. shaft diameter (Any motor available on any unit)  
Total Hp  
20  
30  
40  
2...20  
S256T  
50  
60  
Quantity...Motor Hp  
2...10  
S215T  
2...15  
D254T  
2...25  
S284T  
2...30  
S286T  
Motor Frame Size  
Efficiency at Full Load (%)  
High Efficiency  
89.5  
91.7  
91  
93  
91  
93.6  
91.7  
93.6  
92.4  
93.6  
Premium Efficiency  
Fan Sheave Pitch Diameter (in.)  
Motor Sheave Pitch Diameter (in.)  
Resulting Fan Rpm  
12.4  
12.4  
5.8  
11.1  
11.1  
11.1  
4.8  
714  
1175  
2...BX93  
5.9  
6.5  
6.9  
841  
1175  
2...BX93  
928  
1020  
1094  
Maximum Allowable Rpm  
Belts — Quantity...Type  
1175  
2...5VX950  
1175  
1175  
2...5VX950  
2...5VX950  
Table 4 — Optional Humidi-MiZer® Coil Data  
UNIT SIZE 48/50P  
Humidi-MiZer Coil Construction  
Quantity  
030-075  
090,100  
Aluminum Novation® Coil  
1
1
Face Area (sq ft)  
26.7  
33.3  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 5 — Operating Weights of Options and Accessories (lb)  
48/50P UNIT SIZE  
OPTION OR ACCESSORY  
Condenser Section Roof Curb  
Economizer  
Power Exhaust  
Barometric Relief  
Double Wall Construction  
030,035  
300*  
710*  
200  
040,050  
300*  
710*  
200  
055  
540  
530*  
710*  
200  
900  
060  
540  
530*  
710*  
200  
900  
070  
625  
530*  
710*  
200  
900  
075  
625  
530*  
710*  
200  
900  
090  
625  
530*  
710*  
200  
900  
100  
625  
530*  
710*  
200  
900  
700  
800  
Roof Curb  
Standard Length  
455  
545  
495  
545  
605  
1200  
605  
1200  
605  
605  
700  
605  
700  
605  
700  
Extended Length  
With High-Capacity Power Exhaust  
High-Efficiency Filters  
Bag Filters and Cartridge Filters  
Hail Guard  
20  
35  
120  
95  
20  
35  
150  
95  
20  
40  
145  
115  
20  
40  
145  
115  
20  
40  
210  
115  
20  
210  
115  
20  
210  
115  
20  
210  
115  
Inlet Guide Vanes  
Variable Frequency Drive  
7.5 hp  
10 hp  
15 hp  
20 hp  
25 hp  
30 hp  
40 hp  
50 hp  
60 hp  
75 hp  
20  
20  
35  
35  
53  
20  
20  
35  
35  
53  
35  
35  
53  
53  
53  
35  
35  
53  
53  
53  
35  
35  
53  
53  
53  
53  
53  
53  
53  
152  
53  
53  
53  
53  
152  
53  
53  
53  
53  
152  
High-Capacity Evaporator Coil  
Airfoil Fan  
Humidi-MiZer® Adaptive Dehumidification System  
150  
72  
300  
72  
300  
72  
300  
72  
300  
72  
300  
350  
72  
300  
350  
92  
300  
350  
92  
*Includes hood.  
Table 6 — Supply Fan Drive Data  
SHAFT  
DIA (in.)  
SPEED  
(rpm)  
MOTOR  
SHEAVE  
MOTOR  
PITCH DIA (in.)  
WHEEL  
SHEAVE  
WHEEL  
PITCH DIA (in.)  
QUANTITY  
...BELT  
HP  
Sizes 030-050  
7.5  
10  
15  
20  
25  
13/8  
438  
549  
626  
703  
830  
910  
2BK36  
2B5V42  
2B5V48  
2B5V54  
2B5V64  
3B5V64  
3.4  
4.3  
4.9  
5.5  
6.5  
6.5  
2B5V136  
2B5V136  
2B5V136  
2B5V136  
2B5V136  
3B5V124  
13.7  
13.7  
13.7  
13.7  
13.7  
12.5  
2...BX60  
13/8  
15/8  
15/8  
17/8  
17/8  
2...5VX630  
2...5VX630  
2...5VX630  
2...5VX650  
3...5VX630  
30*  
Sizes 055-070  
15  
20  
25  
30  
40  
15/8  
575  
651  
703  
711  
740  
2B5V44  
2B5V50  
2B5V54  
2B5V62  
3B5V66  
4.5  
5.1  
5.5  
6.3  
6.7  
2B5V136  
2B5V136  
2B5V136  
2B5V154  
3B5V160  
13.7  
13.7  
13.7  
15.5  
16.1  
2...5VX1230  
2...5VX1230  
2...5VX1230  
2...5VX1230  
3...5VX1250  
15/8  
17/8  
17/8  
21/8  
Sizes 075-100 (Forward-Curved Fan)  
30  
40  
50  
60  
17/8  
21/8  
21/8  
23/8  
501  
539  
615  
672  
3B5V52  
4B5V56  
4B5V64  
4B5V70  
5.33  
5.74  
6.54  
7.14  
B5V184  
B5V184  
B5V184  
B5V184  
18.5  
18.5  
18.5  
18.5  
3...5VX1320  
4...5VX1320  
4...5VX1320  
4...5VX1320  
Sizes 075-100 (Airfoil Fan)  
30  
40  
50  
60  
75  
17/8  
21/8  
21/8  
23/8  
23/8  
1353  
1493  
1593  
1711  
1799  
2B5V74  
2B5V86  
3B5V80  
3B5V86  
3B5V110  
7.5  
8.7  
8.1  
8.7  
11.1  
2Q5V97  
2Q5V103  
3R5V90  
3R5V90  
3R5V109  
9.7  
10.2  
8.9  
8.9  
10.8  
2...5VX1150  
2...5VX1180  
3...5VX1150  
3...5VX1150  
3...5VX1230  
*Sizes 040,050 only.  
NOTE: Part numbers are Browning Manufacturing Corp. reference.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 7 — Power Exhaust Fan Drive Data  
MOTOR SHEAVE  
BLOWER SHEAVE  
48P2,P3 UNITS  
48P4,P5 UNITS  
MOTOR  
SHAFT  
FAN  
SPEED  
RPM  
TOTAL MOTOR  
Pitch  
Pitch  
CENTER  
DISTANCE  
CENTER  
DISTANCE  
Part  
Part  
BELTS  
QTY...P/N  
BELTS  
QTY...P/N  
HP  
QTY...HP DIAMETER  
(in.)  
Diameter  
Number  
(in.)  
Diameter  
Number  
(in.)  
RANGE (in.)  
RANGE (in.)  
Sizes 030-050  
7
6*  
6†  
10**  
15**  
20**  
2...3  
/
656/500 1VL44  
656/500 1VP44L  
785/621 1VP50L  
882/717 1VP65  
1000/854 1VP75  
4.1-3.1  
4.1-3.1  
4.7-3.7  
6.0-4.8  
7.0-5.8  
BK115  
BK115  
BK110  
BK130  
BK130  
11  
11  
1...BX71 23.62-26.50 1...BX46 11.40-13.26  
1...BX71 23.62-26.50 1...BX46 11.40-13.26  
1...BX71 23.62-26.50 1...BX46 11.16-13.05  
1...BX77 23.62-26.50 1...BX53 11.40-13.26  
1...BX79 23.62-26.50 1...BX53 11.04-12.95  
8
2...3  
2...5  
11/8  
11/8  
13/8  
13/8  
10.4  
12  
2...7.5  
2...10  
12  
Sizes 055-100  
10  
15  
20  
2...5  
11/8  
13/8  
13/8  
740  
820  
920  
2P3V45  
2P3V50  
2P3V56  
4.5  
5.0  
5.6  
2Q3V106  
2Q3V106  
2Q3V106  
10.6  
10.6  
10.6  
2...3VX71 22.71-26.38 2...3VX50 10.91-13.30  
2...3VX71 22.71-26.38 2...3VX50 10.78-13.20  
2...3VX75 22.71-26.38 2...3VX50 10.78-13.20  
2...7.5  
2...10  
*High-efficiency motor option.  
†Premium-efficiency motor option.  
**Applies to both motor options.  
NOTE: Part numbers are Browning Manufacturing Corp. reference.  
Table 8 — Optional High-Capacity Power Exhaust Fan Drive Data  
MOTOR SHEAVE  
Part Pitch Diameter  
BLOWER SHEAVE  
Part Pitch Diameter  
MOTOR  
SHAFT  
TOTAL MOTOR  
SPEED  
RPM  
CENTER DISTANCE  
RANGE (in.)  
QTY...BELT  
HP  
QTY...HP  
DIA. (in.)  
Number  
2B5V48  
2B5V58  
2B5V58  
2B5V64  
2B5V68  
(in.)  
4.8  
5.8  
5.9  
6.5  
6.9  
Number  
2B5V124  
2B5V124  
2B5V110  
2B5V110  
2B5V110  
(in.)  
12.4  
12.4  
11.1  
11.1  
11.1  
20  
30  
40  
50  
60  
2...10  
2...15  
2...20  
2...25  
2...30  
1.375  
1.625  
1.625  
1.875  
1.875  
714  
841  
928  
1020  
1094  
2...BX93  
2...BX93  
2...5VX950  
2...5VX950  
2...5VX950  
32.8 to 36.7  
32.6 to 36.5  
32.6 to 36.5  
32.5 to 36.3  
32.5 to 36.3  
Table 9 — Optional Return Fan Drive Data  
MOTOR SHEAVE  
BLOWER SHEAVE  
MOTOR  
TOTAL  
HP  
MOTOR  
QTY...HP  
SPEED  
RPM  
CENTER DISTANCE  
RANGE (in.)  
Pitch  
Pitch  
SHAFT  
QTY...BELT  
Part  
Part  
Diameter  
Number  
Diameter  
Number  
DIA. (in.)  
(in.)  
(in.)  
20  
25  
30  
40  
1...20  
1...25  
1...30  
1...40  
1.625  
1.875  
1.875  
2.125  
1104  
1209  
1271  
1396  
3B5V52  
3B5V66  
3B5V60  
3B5V66  
5.3  
6.7  
6.1  
6.7  
3R5V85  
3R5V97  
3R5V85  
3R5V85  
8.5  
9.8  
8.5  
8.5  
3...5VX1000  
3...5VX1060  
3...5VX1030  
3...5VX1060  
38.1 to 41.0  
38.9 to 41.8  
38.9 to 41.8  
39.9 to 42.8  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
"X"  
A
A
CONDENSER  
END SUPPORT  
4
1
4 REF.  
9 3/4"  
2
3
"X"-  
NO GASKET  
DETAIL A-A  
Fig. 6 — Gasket Location on Roof Curb (Size 070-100 Units)  
5
5
Fig. 7 — Gasket Location — Condenser Section Roof Curb (Size 070-100 Units)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
1
3
3
2
Fig. 8 — Gasket Location on Roof Curb (48P075-100 Units with Optional High-Capacity Power Exhaust)  
four 0.20-in. engagement holes. Install a drain coupling assem-  
bly using screws provided at each secondary drain hole loca-  
tion. See Fig. 26. Do not attach any drain coupling assemblies  
in the condenser section base rail.  
Step 8 — Connect Condensate Drain There  
are a total of five drain connections required on each unit: one  
primary drain (on right-hand side of the unit) and four second-  
ary drains (two on each side of unit).  
Using field-supplied fittings and pipe sections, assemble U-  
traps at each secondary drain fitting. See Fig. 27. Provide a  
minimum size of ½-in. pipe for secondary drains. Use a trap at  
least 4-in. deep for size 030-070 units and 7-in. deep for size  
075-100 units. Apply a bead of RTV or similar sealant around  
the drain assemblies.  
Consult local plumbing codes for direction on joining multi-  
ple drain lines. Total size of any combined line does not need  
to exceed nominal 2-in. size of primary drain connection.  
PRIMARY DRAIN — The primary drain is a 2-in. FPT pipe  
connection located on the right-hand side of the unit looking at  
the unit from the return air end. See Fig. 12-21. Fig. 22 shows  
the additional length of units with an extended chassis.  
With field-supplied fittings and pipe sections, plumb the pri-  
mary condensate drain to the 2-in. FPT connector on the base  
rail. Use a trap height of at least 4-in. for size 030-070 units  
and 7-in. for size 075-100 units. See Fig. 23 and 24. Install with  
a height dimension of at least 2-in. from the top of the exit pipe  
from the trap section to the bottom of the connector. Apply a  
bead of RTV or similar sealant around the pipe joint at the con-  
nector in the base rail.  
Fill the U-traps at the secondary drain locations prior to unit  
start-up. Also check the U-traps before each cooling season to  
ensure the traps are filled and functioning properly.  
SECONDARY  
DRAINS  
(Units  
Installed  
on  
SECONDARY DRAINS (Units Installed on Steel Beam or  
Slab) — There are two secondary drain connections required  
on each side of the unit. There are secondary drains on the bot-  
tom of the base rail on each side of the unit in the filter section  
and on each side of the unit in the supply fan section. There are  
labels marking each location on the unit base rail. See Fig. 12-  
21. Drain holes will need to be drilled in these locations at the  
side of the base rail. The existing secondary drain holes in the  
bottom of the base rail must be sealed. Prior to final positioning  
of the unit, apply a bead of RTV or similar sealant around each  
secondary drain hole in the bottom of the unit base rail. See  
Fig. 27. Install the metal seal plates then position the unit into  
final location.  
Curb) — There are two secondary drain connections on each  
side of the unit. See Fig. 25. There are secondary drains on  
each side of the unit in the filter section and on each side of the  
unit in the supply fan section. There are labels marking each lo-  
cation on the unit base rail. See Fig. 12-21.  
Locate the four 11/4-in. drain coupling assemblies and  
mounting screws (shipped in a bag taped to the basepan in the  
supply fan section, located behind the access panel marked  
FAN SECTION). The drain couplings are a 10-gage plate with  
a 11/4 in. half coupling welded to the plate.  
At each secondary drain hole location, there is a 13/8-in.  
hole pre-drilled in the bottom of the base rail, surrounded by  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION - NOTICE TO RIGGERS:  
ALL PANELS MUST BE IN PLACE WHEN RIGGING.  
NOTE: Rig with four cables and spread with two 95 inch (2413 MM) spreader bars.  
CENTER OF GRAVITY  
B
LIFTING LUGS  
C
MODEL POSITION  
4
WEIGHT  
KGS  
A
SIZE  
UNITS  
1,2,3  
48P  
5
LBS  
6019  
6169  
6710  
6925  
9220  
9275  
9615  
10665  
11265  
11285  
6149  
6299  
6840  
7055  
9350  
9405  
9745  
10795  
11395  
11415  
6519  
6669  
7210  
7425  
9770  
9825  
9825  
11215  
11815  
11835  
6649  
6799  
7340  
7555  
9900  
9955  
10295  
11345  
11945  
11965  
5519  
5669  
6210  
6425  
8230  
8285  
8625  
10265  
10865  
10885  
5819  
5969  
6510  
6725  
8780  
8835  
9175  
6019  
6169  
6710  
6925  
8780  
8835  
9175  
10815  
11415  
11435  
6319  
6469  
7010  
7225  
9330  
9385  
9725  
IN  
MM  
4334  
4342  
5035  
5113  
5814  
5803  
6215  
6429  
6628  
6603  
4310  
4319  
5012  
5090  
5816  
5805  
6218  
6462  
6657  
6637  
4753  
4768  
5456  
5534  
6164  
6151  
6575  
6775  
6976  
6944  
4726  
4742  
5431  
5507  
6166  
6153  
6564  
6808  
7005  
6978  
4043  
4049  
4727  
4807  
5401  
5392  
6362  
6354  
6562  
6535  
3867  
3863  
4576  
4665  
5885  
5874  
6287  
4456  
4475  
5151  
5228  
5741  
5731  
6725  
6722  
6932  
6899  
4237  
4244  
4961  
5050  
6226  
6214  
6625  
IN  
MM  
1164  
1164  
1164  
1164  
1164  
1164  
1021  
1021  
1054  
1054  
1164  
1164  
1164  
1164  
1164  
1164  
1021  
1021  
1054  
1054  
1164  
1164  
1164  
1164  
1164  
1164  
1021  
1021  
1054  
1054  
1164  
1164  
1164  
1164  
1164  
1164  
1021  
1021  
1054  
1054  
1164  
1164  
1164  
1164  
1164  
1164  
1021  
1021  
1054  
1054  
1164  
1164  
1164  
1164  
1164  
1164  
1021  
1164  
1164  
1164  
1164  
1164  
1164  
1021  
1021  
1054  
1054  
1164  
1164  
1164  
1164  
1164  
1164  
1164  
IN  
MM  
4227  
4227  
4707  
4707  
6541  
6541  
5563  
6495  
6495  
6495  
4227  
4227  
4707  
4707  
6541  
6541  
5563  
6495  
6495  
6495  
4867  
4867  
5288  
5288  
6939  
6939  
6355  
7132  
7132  
7132  
4867  
4867  
5288  
5288  
6939  
6939  
6355  
7132  
7132  
7132  
3762  
3762  
4305  
4305  
5347  
5347  
4483  
6495  
6495  
6495  
4227  
4227  
4707  
4707  
6541  
6541  
5563  
4402  
4402  
4945  
4945  
5288  
5288  
5123  
7132  
7132  
7132  
4867  
4867  
5288  
5288  
6939  
6939  
6355  
2,3,4,5  
2,3,4,5  
2,3,4,5  
2,3,4,5  
B,D,H  
C,E,J  
P,R,W  
Q,S,X  
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
030  
035  
040  
050  
055  
060  
070  
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
030  
035  
040  
050  
055  
060  
070  
2730  
2798  
3044  
3141  
4182  
4207  
4361  
4838  
5110  
5119  
2789  
2857  
3103  
3200  
4241  
4266  
4420  
4897  
5169  
5178  
2957  
3025  
3270  
3368  
4432  
4457  
4457  
5087  
5359  
5368  
3016  
3084  
3329  
3427  
4491  
4516  
4670  
5146  
5418  
5427  
2503  
2571  
2817  
2914  
3733  
3758  
3912  
4656  
4928  
4937  
2639  
2708  
2953  
3050  
3983  
4008  
4162  
2730  
2798  
3044  
3141  
3983  
4008  
4162  
4906  
5178  
5187  
2866  
2934  
3180  
3277  
4232  
4257  
4411  
170.6  
170.9  
198.2  
201.3  
228.9  
228.5  
244.7  
253.1  
260.9  
260.0  
169.7  
170.0  
197.3  
200.4  
229.0  
228.5  
244.8  
254.4  
262.1  
261.3  
187.1  
187.7  
214.8  
217.9  
242.7  
242.2  
258.8  
266.7  
274.7  
273.4  
186.1  
186.7  
213.8  
216.8  
242.7  
242.3  
258.4  
268.0  
275.8  
274.7  
159.2  
159.4  
186.1  
189.3  
212.6  
212.3  
250.5  
250.1  
258.4  
257.3  
152.3  
152.1  
180.2  
183.6  
231.7  
231.3  
247.5  
175.4  
176.2  
202.8  
205.8  
226.0  
225.6  
264.8  
264.6  
272.9  
271.6  
166.8  
167.1  
195.3  
198.8  
245.1  
244.7  
260.8  
45.8  
45.8  
45.8  
45.8  
45.8  
45.8  
40.2  
40.2  
41.5  
41.5  
45.8  
45.8  
45.8  
45.8  
45.8  
45.8  
40.2  
40.2  
41.5  
41.5  
45.8  
45.8  
45.8  
45.8  
45.8  
45.8  
40.2  
40.2  
41.5  
41.5  
45.8  
45.8  
45.8  
45.8  
45.8  
45.8  
40.2  
40.2  
41.5  
41.5  
45.8  
45.8  
45.8  
45.8  
45.8  
45.8  
40.2  
40.2  
41.5  
41.5  
45.8  
45.8  
45.8  
45.8  
45.8  
45.8  
40.2  
45.8  
45.8  
45.8  
45.8  
45.8  
45.8  
40.2  
40.2  
41.5  
41.5  
45.8  
45.8  
45.8  
45.8  
45.8  
45.8  
45.8  
166.4  
166.4  
185.3  
185.3  
257.5  
257.5  
219.0  
255.7  
255.7  
255.7  
166.4  
166.4  
185.3  
185.3  
257.5  
257.5  
219.0  
255.7  
255.7  
255.7  
191.6  
191.6  
208.2  
208.2  
273.2  
273.2  
250.2  
280.8  
280.8  
280.8  
191.6  
191.6  
208.2  
208.2  
273.2  
273.2  
250.2  
280.8  
280.8  
280.8  
148.1  
148.1  
169.5  
169.5  
210.5  
210.5  
176.5  
255.7  
255.7  
255.7  
166.4  
166.4  
185.3  
185.3  
257.5  
257.5  
219.0  
173.3  
173.3  
194.7  
194.7  
208.2  
208.2  
201.7  
280.8  
280.8  
280.8  
191.6  
191.6  
208.2  
208.2  
273.2  
273.2  
250.2  
48 P2, P3, P4, P5  
Vertical Supply/ Return  
Horizontal Supply/ Return  
Low Gas Heat  
48P  
48P  
48P  
50P  
48 P2, P3, P4, P5  
Vertical Supply/ Return  
Horizontal Supply/ Return  
High Gas Heat  
48 P2, P3, P4, P5  
Vertical Supply/ Return  
Horizontal Supply/ Return  
Low Gas Heat  
Extended Chassis  
48 P2, P3, P4, P5  
Vertical Supply/ Return  
Horizontal Supply/ Return  
High Gas Heat  
Extended Chassis  
2,3  
-,A,B,C  
-,B,C  
50 P2, P3  
Vertical Supply/ Return  
50P  
50P  
2,3,4,5  
50 P2, P3, P4, P5  
Vertical Supply/ Return  
Horizontal Supply/ Return  
2,3  
4,5  
H
-
50 P2, P3  
Vert Supply/ Return w/ Ext Plenum  
50 P4, P5  
Horizontal Supply/ Return  
50P  
2,3  
R,S,T,V,W  
50 P2, P3  
Vertical Supply/ Return  
w/ Extended Chassis  
50P  
50P  
2,3,4,5  
R,T,V,W  
50 P2, P3, P4, P5  
Vert, Horz Supply/ Return  
w/ Extended Chassis  
2,3  
4,5  
P,Y  
R,W  
50 P2, P3  
Vert Supply/ Return w/ Ext Plenum  
w/ Extended Chassis  
50 P4, P5  
Horizontal Supply/ Return  
w/ Extended Chassis  
NOTE:  
1. Weights do not include economizer or  
power exhaust.  
a48-8455  
48ZZ501077 2.0  
Fig. 9 — Rigging Label — Units without Optional Return Fan or High-Capacity Power Exhaust  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION - NOTICE TO RIGGERS:  
ALL PANELS MUST BE IN PLACE WHEN RIGGING.  
NOTE: Rig with four cables and spread with two 95 inch (2413 MM) spreader bars.  
CENTER OF GRAVITY  
LIFTING LUGS  
C
MODEL POSITION  
WEIGHT  
LBS KGS  
A
B
SIZE  
UNITS  
1,2,3  
4
5
IN  
MM  
IN  
MM  
IN  
MM  
50P 2,3,4,5  
48P 2,3,4,5  
48P 2,3,4,5  
-,B,C  
50 P2, P3, P4, P5  
075 11921 5407 220.1 5590  
090 12521 5679 228.4 5800  
100 12541 5689 227.8 5786  
075 12321 5589 224.6 5706  
090 12921 5861 232.6 5908  
100 12941 5870 230.4 5853  
075 12451 5648 226.9 5764  
090 13051 5920 233.7 5936  
100 13071 5929 232.9 5915  
40.2  
41.5  
41.5  
40.2  
41.5  
41.5  
40.2  
41.5  
41.5  
1021 255.7 6495  
1054 255.7 6495  
1054 255.7 6495  
1021 255.7 6495  
1054 255.7 6495  
1054 255.7 6495  
1021 255.7 6495  
1054 255.7 6495  
1054 255.7 6495  
Vert Supply/Return w/ RE Fan  
Horz Supply Vert Return w/ RE Fan  
B,D,H  
C,E,J  
48 P2, P3, P4, P5 Low Gas Heat  
Vert Supply/Return w/ RE Fan  
Horz Supply Vert Return w/ RE Fan  
48 P2, P3, P4, P5 High Gas Heat  
Vert Supply/Return w/ RE Fan  
Horz Supply Vert Return w/ RE Fan  
50P 2,3,4,5 R,T,V,W  
50 P2, P3, P4, P5  
075 12471 5657 231.7 5885  
090 13071 5929 240.1 6098  
100 13091 5938 239.2 6075  
40.2  
41.5  
41.5  
1021 280.8 7132  
1054 280.8 7132  
1054 280.8 7132  
a48-8456  
Vert Sup/Ret, Horz Sup/ Vert Ret  
w/ RE Fan, w/ Ext Chassis  
48P 2,3,4,5  
48P 2,3,4,5  
48P 2,3,4,5  
48P 2,3,4,5  
50P 2,3,4,5  
P,R,W  
Q,S,X  
B,D,H  
C,E,J  
-,B,C  
48 P2, P3, P4, P5 Low Gas Heat  
Vert Sup/Ret, Horz Sup/ Vert Ret  
w/ RE Fan, w/ Ext Chassis  
48 P2, P3, P4, P5 High Gas Heat  
Vert Sup/Ret, Horz Sup/ Vert Ret  
w/ RE Fan, w/ Ext Chassis  
48 P2, P3, P4, P5 Low Gas Heat  
Vert Sup/Ret, Horz Sup/Ret  
w/ Hi Cap PE  
48 P2, P3, P4, P5 High Gas Heat  
Vert Sup/Ret, Horz Sup/Ret  
w/ Hi Cap PE  
075 12871 5838 236.2 6000  
090 13471 6110 244.3 6205  
100 13491 6119 241.8 6142  
075 13001 5897 238.5 6058  
090 13601 6169 245.4 6234  
100 13621 6178 244.2 6203  
075 13499 6123 290.1 7367  
090 14097 6394 297.7 7561  
100 14119 6404 297.1 7546  
075 13629 6182 291.3 7400  
090 14227 6453 298.9 7593  
100 14249 6463 298.2 7575  
40.2  
41.5  
41.5  
40.2  
41.5  
41.5  
40.2  
41.5  
41.5  
40.2  
41.5  
41.5  
1021 280.8 7132  
1054 280.8 7132  
1054 280.8 7132  
1021 280.8 7132  
1054 280.8 7132  
1054 280.8 7132  
1021 312.1 7927  
1054 312.1 7927  
1054 312.1 7927  
1021 312.1 7927  
1054 312.1 7927  
1054 312.1 7927  
50 P2, P3, P4, P5  
Vert Sup/Ret, Horz Sup/Ret  
w/ Hi Cap PE  
075 13099 5942 287.1 7293  
090 13697 6213 295.1 7496  
100 13719 6223 294.4 7478  
40.2  
41.5  
41.5  
1021 312.1 7927  
1054 312.1 7927  
1054 312.1 7927  
48P 2,3,4,5 R,T,V,W  
48 P2, P3, P4, P5 Low Gas Heat  
Vert Sup/Ret, Horz Sup/Ret  
w/ Hi Cap PE w/ Ext Chassis  
075 14049 6373 483.5 12280 40.2  
090 14647 6644 484.3 12302 41.5  
100 14669 6654 493.8 12542 41.5  
1021 337.3 8567  
1054 337.3 8567  
1054 337.3 8567  
48P 2,3,4,5  
50P 2,3,4,5  
P,R,W  
Q,S,X  
48 P2, P3, P4, P5 High Gas Heat  
Vert Sup/Ret, Horz Sup/Ret  
w/ Hi Cap PE w/ Ext Chassis  
50 P2, P3, P4, P5  
Vert Sup/Ret, Horz Sup/Ret  
w/ Hi Cap PE w/ Ext Chassis  
075 14179 6432 483.5 12280 40.2  
090 14777 6703 484.3 12301 41.5  
100 14799 6713 493.8 12542 41.5  
075 13649 6191 483.5 12281 40.2  
090 14247 6462 484.4 12304 41.5  
100 14269 6472 493.8 12543 41.5  
1021 337.3 8567  
1054 337.3 8567  
1054 337.3 8567  
1021 337.3 8567  
1054 337.3 8567  
1054 337.3 8567  
48ZZ501078 2.0  
Fig. 10 — Rigging Label — Units with Optional Return Fan or High-Capacity Power Exhaust  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
3
2
B
1
A
CORNER WEIGHTS (lb)  
A
in.  
B
in.  
TOTAL  
(lb)  
48P2,P3,P4,P5 UNITS  
SIZE  
1
2
3
4
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
2002  
2056  
1983  
2079  
2408  
2417  
2950  
3385  
3255  
3248  
2034  
2088  
2013  
2108  
2443  
2452  
2991  
3444  
3307  
3303  
1009  
1031  
1374  
1386  
2205  
2223  
2450  
2604  
2911  
2929  
1042  
1064  
1410  
1422  
2236  
2254  
2481  
2618  
2931  
2946  
1008  
1029  
1372  
1384  
2202  
2220  
1913  
2033  
2407  
2422  
1041  
1062  
1408  
1420  
2233  
2250  
1937  
2044  
2424  
2436  
2000  
2053  
1981  
2076  
2404  
2414  
2303  
2643  
2691  
2686  
2032  
2085  
2010  
2105  
2439  
2449  
2335  
2689  
2734  
2731  
6,019  
6,169  
6,710  
6,925  
9,220  
9,275  
9,615  
10,665  
11,265  
11,285  
6,149  
6,299  
6,840  
7,055  
9,350  
9,405  
9,745  
10,795  
11,395  
11,415  
170 5/8  
170 7/8  
198 1/4  
201 1/4  
228 7/8  
228 1/2  
244 5/8  
253 1/8  
261  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
40 1/4  
40 1/4  
Vertical Supply/Return  
Horizontal Supply/Return  
Low Heat  
No Extended Chassis  
41 1  
/
/
2
260  
41 1  
2
169 3/4  
170  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
40 1/4  
40 1/4  
41 1/2  
41 1/2  
Vertical Supply/Return  
Horizontal Supply/Return  
High Heat  
197 3/8  
200 3/8  
229  
No Extended Chassis  
228 1/2  
244 3/4  
254 3/8  
262 1/8  
261 1/4  
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
030  
035  
040  
050  
055  
060  
070  
075  
090  
100  
2166  
2223  
2148  
2244  
2558  
2567  
3117  
3551  
3419  
3409  
2197  
2253  
2177  
2272  
2592  
2602  
3158  
3610  
3471  
3463  
1096  
1114  
1460  
1471  
2331  
2349  
2541  
2747  
3048  
3070  
1130  
1148  
1496  
1508  
2361  
2379  
2623  
2761  
3068  
3086  
1094  
1112  
1458  
1469  
2328  
2346  
2023  
2145  
2521  
2538  
1129  
1147  
1494  
1506  
2358  
2376  
2048  
2156  
2537  
2552  
2163  
2220  
2145  
2241  
2554  
2563  
2434  
2773  
2827  
2819  
2194  
2250  
2174  
2269  
2589  
2598  
2466  
2818  
2870  
2864  
6,519  
6,669  
187 1/8  
187 3/4  
214 3/4  
217 7/8  
242 5/8  
242 1/8  
258 7/8  
266 3/4  
274 5/8  
273 3/8  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
40 1/4  
40 1/4  
41 1/2  
41 1/2  
Vertical Supply/Return  
Horizontal Supply/Return  
Low Heat  
7,210  
7,425  
with Extended Chassis  
9,770  
9,825  
10,165  
11,215  
11,815  
11,835  
6,649  
6,799  
186 1/8  
186 5/8  
213 3/4  
216 7/8  
242 3/4  
242 1/4  
258 1/2  
268  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
45 7/8  
40 1/4  
Vertical Supply/Return  
Horizontal Supply/Return  
High Heat  
7,340  
7,555  
with Extended Chassis  
9,900  
9,955  
10,295  
11,345  
11,945  
11,965  
40 1  
/
4
275 3/4  
274 3/4  
41 1/2  
41 1/2  
CORNER WEIGHTS (lb)  
A
in.  
B
48P2,P3,P4,P5 UNITS WITH  
OPTIONAL HIGH-CAPACITY POWER EXHAUST  
TOTAL  
(lb)  
SIZE  
1
2
3
4
in.  
075  
090  
100  
075  
090  
100  
4171  
4004  
4002  
4230  
4058  
4054  
3410  
3712  
3726  
2662  
3070  
3081  
3256  
3311  
3309  
3302  
3356  
3352  
13,499  
14,097  
14,119  
13,629  
14,227  
14,249  
290  
40 1  
/
Vertical Supply/Return  
Horizontal Supply/Return  
Low Heat  
Vertical Supply/Return  
Horizontal Supply/Return  
High Heat  
297 5/8  
297 1/8  
41 1/42  
41 1/2  
3424  
3730  
3745  
2673  
3084  
3097  
291 3/8  
299  
40 1/4  
41 1  
/
2
298 1/4  
41 1/2  
075  
090  
100  
075  
090  
100  
6905  
6484  
6620  
6969  
6541  
6679  
984  
1534  
1409  
993  
1547  
1422  
768  
1268  
1165  
776  
1280  
1176  
5391  
5362  
5474  
5441  
5409  
5523  
14,049  
14,647  
14,669  
14,179  
14,777  
14,799  
483 1/2  
484 3/8  
493 3/4  
483 1/2  
484 1/4  
493 3/4  
40 1/4  
41 1/2  
41 1/2  
40 1/4  
41 1/2  
41 1/2  
Vertical Supply/Return  
Horizontal Supply/Return  
Low Heat with Extended Chassis  
Vertical Supply/Return  
Horizontal Supply/Return  
High Heat with Extended Chassis  
NOTE: The weight distribution and center of gravity information include the impact of an economizer, the largest indoor fan motor, and a VFD (variable frequency  
drive). On units with a return fan or high-capacity power exhaust, the largest motors and VFD are also included. These weights do not include the impact of other  
factory-installed options such as barometric relief, power exhaust, high-capacity indoor coil, hot water coil, or indoor fan.  
Fig. 11 — Weight Distribution and Center of Gravity  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
3
2
B
1
A
CORNER WEIGHTS (lb)  
A
in.  
B
in.  
48P2,P3,P4,P5 UNITS  
WITH OPTIONAL RETURN FAN  
TOTAL  
(lb)  
SIZE  
1
2
3
4
075  
090  
100  
075  
090  
100  
3470  
3327  
3302  
3543  
3377  
3370  
3449  
3745  
3782  
3449  
3767  
3785  
2693  
3097  
3127  
2693  
3115  
3130  
2709  
2751  
2730  
2766  
2793  
2787  
12,321  
12,921  
12,941  
12,451  
13,051  
13,071  
224 5/8  
232 5/8  
230 3/8  
226 7/8  
233 3/4  
232 7/8  
40 1/4  
41 1/2  
41 1/2  
40 1/4  
41 1/2  
41 1/2  
Vertical Supply/Return  
Horizontal Supply/Return  
Low Heat  
Vertical Supply/Return  
Horizontal Supply/Return  
High Heat  
075  
090  
100  
075  
090  
100  
3609  
3467  
3437  
3681  
3517  
3505  
3618  
3906  
3948  
3620  
3928  
3951  
2825  
3230  
3264  
2826  
3248  
3267  
2818  
2867  
2842  
2874  
2908  
2898  
12,871  
13,471  
13,491  
13,001  
13,601  
13,621  
236 1/4  
244 1/4  
241 3/4  
238 1/2  
245 3/8  
244 1/4  
40 1/4  
41 1/2  
41 1/2  
40 1/4  
41 1/2  
41 1/2  
Vertical Supply/Return  
Horizontal Supply/Return  
Low Heat with Extended Chassis  
Vertical Supply/Return  
Horizontal Supply/Return  
High Heat with Extended Chassis  
NOTE: The weight distribution and center of gravity information include the impact of an economizer, the largest indoor fan motor, and a VFD (variable frequency  
drive). On units with a return fan or high-capacity power exhaust, the largest motors and VFD are also included. These weights do not include the impact of other  
factory-installed options such as barometric relief, power exhaust, high-capacity indoor coil, hot water coil, or indoor fan.  
Fig. 11 — Weight Distribution and Center of Gravity (cont)  
Locate the four 11/4-in. drain coupling assemblies and  
mounting screws (shipped in a bag taped to the basepan in the  
supply fan section, located behind the access panel marked  
FAN SECTION). The drain couplings are a 10-gage plate with  
a 11/4 in. half coupling welded to the plate.  
4. Using field-supplied fittings and pipe sections, assemble  
U-traps at each secondary drain fitting. See Fig. 24. Pro-  
vide minimum size of ½-in. pipe for secondary drains.  
Use a trap at least 4-in. deep for size 030-070 units and  
7-in. deep for size 075-100 units.  
After final positioning of the unit, perform the following  
procedure:  
5. Apply a bead of RTV or similar sealant around the drain  
assemblies.  
1. At each of the four secondary drain locations (marked  
with labels on the unit base rail), position the drain cou-  
pling assembly in the side of the base rail. Mark the  
screw holes and the drain hole locations on the base rail.  
Consult local plumbing codes for direction on joining multi-  
ple drain lines. Total size of any combined line does not need to  
exceed nominal 2-in. size of primary drain connection.  
Fill the U-traps at the secondary drain locations prior to unit  
start-up. Also check the U-traps before each cooling season to  
ensure the traps are filled and functioning properly.  
2. Drill holes for drain outlet (use 13/8-in. hole saw) and for  
the mounting screws (use 3/16-in. drill bit).  
3. Install a drain coupling assembly using screws provided  
at each secondary drain hole location.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8613  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8614  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8615  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8616  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8617  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8618  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8619  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8620  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8621  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8622  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B
A
AUXILIARY COIL LOCATION (in.)  
UNIT  
DISTANCE A HEIGHT B  
a48457  
SIZES  
030,035  
040,050  
055-070  
075-100  
123.0  
156.8  
200.4  
200.4  
6.6  
6.6  
6.6  
6.6  
075-100 with High-  
Capacity Power Exhaust  
279.2  
6.6  
Fig. 22 — Units with Optional Extended Chassis — Location of Coil Tracks  
Fig. 25 — Secondary Condensate Drain  
Location (Curb Mount)  
Fig. 23 — Primary Drain Connection  
a48-8460  
a48-8458  
2” MIN.  
(51 mm)  
A
2” MIN.  
(51 mm)  
A
A = 4-in. (102 mm) min — Sizes 030-070  
7-in. (178 mm) min — Sizes 075-100  
A = 4-in. (102 mm) min — sizes 030-070  
7-in. (178 mm) min — sizes 075-100  
Fig. 24 — Slab-Mounted Condensate  
Drain Piping Details  
Fig. 26 — Curb-Mounted Condensate  
Drain Pipe Details  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Apply a bead of RTV or similar sealant to corner of econ-  
omizer hood at pivot points to prevent water leaks. See  
Fig. 29.  
a48-8459  
OUTDOOR  
AIR HOOD  
16-GAGE METAL  
SEAL PLATE  
(FIELD SUPPLIED  
FIELD INSTALLED)  
BOTTOM OF  
BASE RAIL  
OUTDOOR  
AIR HOOD  
Fig. 28 — Outdoor Air Hood Installation  
(Sizes 030-050)  
Fig. 27 — Secondary Drain Seal Plate  
Location (Slab Mount)  
Step 9 — Install Outdoor Hoods (Units without  
Optional High-Capacity Power Exhaust)  
UNIT SIZES 030-050  
a48-8461  
25% Outdoor-Air Hoods (Units without Economizer  
Option) (Fig. 28)  
OUTDOOR-AIR HOOD  
1. Outdoor-air hoods are shipped bolted to the unit in a ship-  
ping position. Remove the 6 screws holding each 25%  
outdoor air hood shipping cover in place.  
4”  
2. Remove the holddown screw from each upper corner of  
each hood.  
3. Pivot hoods outward (2 hoods).  
RTV  
(ALL HOODS)  
4. Install 17 screws around outside of each hood. (Screws  
are in the fastener package taped to the basepan inside the  
fan section.)  
Fig. 29 — Outdoor-Air and Economizer Hood  
5. Apply a bead of RTV or similar sealant to corner of each  
hood at pivot points to prevent water leaks. See Fig. 29.  
Economizer Hoods (Units with Economizer Option)  
(Fig. 30 and 31)  
SIDE HOOD  
(ROTATE  
OPEN)  
1. Remove the 4 screws holding each of the 2 economizer  
side hoods in place.  
2. Pivot hoods outwards (2 hoods).  
3. Apply seal strip to vertical flange of hood sides.  
4. Install hood sides of hood top using 19 screws (7 each  
side, 5 top). Screws are in fastener package located with  
the hood sides and seal strip which is taped inside the  
unit.  
SIDE HOOD  
(ROTATE  
OPEN)  
END HOOD  
(FIXED)  
5. Apply a bead of RTV or similar sealant to corners of  
economizer hoods at pivot points to prevent water leaks.  
See Fig. 29.  
Fig. 30 — Economizer Outdoor-Air Hood  
Installation (Sizes 030-050)  
UNIT SIZES 055-100  
25% Outdoor-Air Hoods (Fig. 32) — The outdoor-air hoods  
are factory installed on the 055-100 units.  
SIDE HOOD  
(ROTATE  
OPEN)  
Economizer Hoods (Units with Economizer Option) (Fig. 33-35)  
END HOOD  
(FIXED)  
1. Remove the 6 screws holding each of the 4 economizer  
shipping covers in place.  
2. Remove the holddown screw from each upper corner of  
each economizer hood.  
3. Pivot hoods outward (4 hoods).  
4. Apply seal strip to vertical flange of hood sides.  
5. Install 18 screws (5 each side, 6 top, and 2 bottom)  
around the outside of each hood. (Screws are in the fas-  
tener package taped to the basepan inside the fan section.)  
SIDE HOOD  
(ROTATE  
OPEN)  
POWER EXHAUST (FIXED)  
Fig. 31 — Economizer with Power Exhaust  
Outdoor-Air Hood Installation (Sizes 030-050)  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 10 — Install Economizer Hoods (Units  
with Optional High-Capacity Power  
Exhaust) — The economizer uses a total of 4 outdoor  
intake hoods, 2 on each side of the unit. See Fig. 36. Two small  
hoods (one per side) are factory-installed and are pivoted  
inside the unit chassis for shipment. Two large hoods are  
shipped in packages located inside the unit. The large hoods  
(one on each side) require field assembly and mounting.  
INSTALL SMALL HOODS — To install the small econo-  
mizer hoods, perform the following procedure:  
1. Remove the 10 screws holding each of the small econo-  
mizer hood shipping covers in place.  
OUTDOOR  
AIR HOODS  
(FIXED)  
2. Pivot hoods outward. (There are a total of 2 hoods.)  
3. Apply seal strip to vertical flange of hood sides.  
Fig. 32 — 25% Outdoor-Air Hood Location  
4. Install 15 screws (4 each side, 7 across top) around the  
outside of each hood. Screws are in the fastener package  
taped to the basepan inside the fan section.  
5. Apply a bead of RTV or similar sealant to corner of econ-  
omizer hood at pivot points to prevent water leaks. (See  
Fig. 29.)  
SIDE HOODS  
(ROTATE OPEN)  
INSTALL LARGE HOODS — Large hoods are shipped dis-  
assembled in the economizer section of the unit behind the  
large economizer hood shipping cover. See Fig. 37 for assem-  
bly details for large economizer hoods. To install the large  
economizer hoods, perform the following procedure:  
END HOODS  
(FIXED)  
1. Remove the 17 screws holding each of the large econo-  
mizer hood shipping covers in place.  
SIDE HOODS  
(ROTATE  
OPEN)  
2. Remove the packages containing the disassembled large  
economizer hoods (total of 2 packages). Each package  
contains the following (see Fig. 37 for Item numbers): left  
hood side (Item 1), right hood side (Item 2), hood top  
(Item 3), hood front (Item 4), top filter flange (Item 5), 4  
side filter flanges (Item 6), bottom support (Item 7), front  
support (Item 8), 6 filters (Item 9), 9 filter clips (Item 10),  
seal strip, and fasteners.  
Fig. 33 — Economizer Outdoor-Air Hood  
Installation (Sizes 055-100)  
SIDE HOODS  
(ROTATE OPEN)  
3. Place seal strip on backside of bottom support (Item 7)  
along entire length of support, covering 6 clearance holes.  
4. Attach bottom support piece (Item 7) to unit. Be sure seal  
strip is between bottom support and panel on unit.  
5. Place seal strip on 3/4-in. flange on both the left and right  
hood sides (Items 1 and 2).  
6. Attach the side filter flanges (Item 6) to the left and right  
hood sides (Items 1 and 2), 2 on each hood side.  
END HOODS  
(FIXED)  
7. Attach left and right hood sides (Items 1 and 2) to unit. Be  
sure seal strip is between hood side and unit.  
8. Place seal strip on 3/4-in. flange on hood top (Item 3).  
9. Attach top filter flange (Item 5) to hood top (Item 3).  
10. Attach top hood to unit and to hood sides. Be sure seal  
strip is between hood top and unit.  
SIDE HOODS  
POWER  
(ROTATE  
EXHAUST (FIXED)  
OPEN)  
Fig. 34 — Economizer with Power Exhaust  
Outdoor-Air Hood Installation (Sizes 055-100)  
SIDE HOODS  
(ROTATE OPEN)  
11. Attach front support (Item 8) between left and right hood  
sides.  
12. Place seal strip on all filter flanges.  
13. Attach filter clips (Item 10) to front and bottom supports  
(Items 7 and 8).  
14. Install filters (Item 9). Filters are held in place with filter  
clips.  
15. Attach hood front (Item 4) to hood top and sides.  
END HOODS  
(FIXED)  
16. Apply RTV or similar sealant to 6 places shown in  
Fig. 37.  
SIDE HOODS  
RETURN/  
(ROTATE  
EXHAUST (FIXED)  
OPEN)  
Fig. 35 — Economizer with Return  
Fan Outdoor-Air Hood Installation  
(Units with Optional Return Fan)  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PE VFD  
ACCESS DOOR  
AUXILIARY  
CONTROL BOX  
LARGE ECONOMIZER  
HOOD LOCATION  
EXHAUST  
AIR  
POWER EXHAUST  
ACCESS DOOR  
SMALL ECONOMIZER  
HOOD LOCATION  
LEGEND  
PE VFD — Power Exhaust Variable Frequency Drive  
Fig. 36 — Economizer Hood Location — Units with High-Capacity Power Exhaust  
APPLYRTV INTHE  
INDICATED AREAS  
ITEM 5  
ITEM 3  
SEE DETAIL Z  
ITEM 6  
DETAILZ  
SCALE 3:4  
ITEM 1  
ITEM 8  
ITEM 7  
ITEM 2  
AND BOTH ENDS OF  
BOTTOM FILTER ROW  
ITEM 10  
ITEM 9  
ITEM 4  
a48-8462  
Fig. 37 — Large Economizer Hood Assembly  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
terminal block and equipment ground. Maximum wire size is  
two (2) 500 MCM (maximum wire size) conductors per pole.  
Step 11 — Route Field Wiring  
UNIT SIZES 030-060 — Field wiring can be brought into the  
unit through the basepan and roof curb or through the corner  
post in the side of the unit next to the control box.  
Units with Factory-Installed Disconnect — The factory-  
installed disconnect is an interlocking, door-type. The discon-  
nect handle locks the door when it is in the ON position. The  
disconnect handle must be in the OFF position to open the con-  
trol box door. The disconnect is located in the control box be-  
hind the control box door for all units. See Fig. 42.  
All field wiring must comply with NEC and all local codes.  
Wire must be sized based on MCA (minimum circuit amps) on  
the unit informative plate. See Fig. 43 for power wiring con-  
nections to the unit disconnect and equipment ground.  
A 31/2-in. FPT coupling for field power and a /4-in. FPT  
3
coupling for 24 v control wiring are provided in the basepan.  
There are two 7/8-in. pilot holes in the corner post as shown on  
the certified drawings. Use these holes as pilot holes for mak-  
ing the hole for field-supplied conduit in the corner post for  
field power wiring.  
CAUTION  
QUANTITY...MAXIMUM WIRE SIZE  
DISCONNECT SIZE  
(MCM)  
Use care when drilling near condenser coil. Damage to unit  
could result.  
250 Amps  
400 Amps  
600 Amps  
1...300  
1...600  
2...600  
If field power wiring is brought through the roof curb, route  
wiring out through one of the holes to the field-supplied dis-  
connect and then back into the unit through the other hole. See  
Fig. 38 and 39 for recommended disconnect location.  
If power wiring is brought through the side of the unit, route  
wiring from field-supplied disconnect through top hole into  
unit.  
Operating Voltage — Operating voltage to the compressor  
must be within the voltage range indicated on the unit name-  
plate. Voltages between phases must be balanced within 2%,  
and the current must be balanced within 10%. See Tables 10-25  
for unit electrical data.  
Use the following formula to determine the percentage of  
voltage imbalance.  
If control wiring is to be brought in through the side of the  
7
unit, a /8-in. diameter hole must be drilled in the corner post  
Voltage Imbalance  
next to the control box.  
UNIT SIZES 070-100 — Field wiring is brought into the unit  
through the bottom of the control box. Wiring can be brought  
through the roof curb through field-supplied watertight connec-  
tions. See Fig. 40.  
A 45/32-in. hole for field power wiring and a 7/8-in. hole for  
24 v control wiring are provided in the bottom of the control  
box. Field-supplied couplings must be used when routing wir-  
ing into the control box.  
max voltage deviation from average voltage  
= 100 x  
average voltage  
Example: Supply voltage is 460-3-60.  
AB = 452 v  
BC = 464 v  
AC = 455 v  
455 + 464 + 455  
Average Voltage =  
3
See Fig. 40 for recommended disconnect location.  
Step 12 — Make Field Electrical Connections  
1371  
=
3
IMPORTANT: Units with VFDs (variable frequency  
drives) generate, use, and can radiate radio frequency  
energy. If units are not installed and used in accordance  
with these instructions, they may cause radio interfer-  
ence. They have been tested and found to comply with  
limits of a Class A computing device as defined by FCC  
(Federal Communications Commission) regulations,  
Subpart J of Part 15, which are designed to provide rea-  
sonable protection against such interference when oper-  
ated in a commercial environment.  
=
457  
Determine maximum deviation from average voltage:  
(AB) 457 – 452 = 5 v  
(BC) 464 – 457 = 7 v  
(AC) 457 – 455 = 2 v  
Maximum deviation is 7 v.  
Determine percent voltage imbalance:  
7
% Voltage Imbalance = 100 x  
457  
POWER WIRING — Units are factory wired for the voltage  
shown on the unit nameplate. The main terminal block is suit-  
able for use with aluminum or copper wires. Maximum wire  
size varies according to disconnect size.  
Units without Factory-Installed Disconnect — When install-  
ing units, provide a disconnect per NEC (National Electrical  
Code) of adequate size (MOCP [maximum overcurrent protec-  
tion] of unit is on the informative plate). All field wiring must  
comply with NEC and all local codes. Size wire based on  
MCA (minimum circuit amps) on the unit informative plate.  
See Fig. 41 for power wiring connections to the unit power  
= 1.53%  
This amount of phase imbalance is satisfactory as it is be-  
low the maximum allowable 2%.  
IMPORTANT: If the supply voltage phase imbalance is  
more than 2%, contact local utility immediately.  
Unit failure as a result of operation on improper line voltage  
or excessive phase imbalance constitutes abuse and may cause  
damage to electrical components.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROL BOX  
RECOMMENDED  
FIELD-SUPPLIED  
DISCONNECT LOCATION  
CAUTION  
a48-8463  
Use care when drilling into corner post to avoid damage to con-  
denser coil.  
Fig. 38 — Disconnect Location — Size 030 and 035 Units  
CAUTION  
a48-8464  
Use care when drilling into corner post to avoid damage to con-  
denser coil.  
Fig. 39 — Disconnect Location — Size 040-060 Units  
CONTROL BOX  
RECOMMENDED  
FIELD-SUPPLIED  
DISCONNECT  
LOCATION  
CAUTION  
a48-8465  
Use care when drilling into corner post to avoid damage to con-  
denser coil.  
Fig. 40 — Disconnect Location — Size 070-100 Units  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FACTORY  
WIRE  
TB1  
21  
22  
11  
12  
23  
22  
21  
DISCONNECT PER NEC  
13  
23  
DISCONNECT  
PER NEC  
EQUIP  
GND  
EQUIP GND  
LEGEND  
13  
12  
11  
EQUIP — Equipment  
GND — Ground  
NEC — National Electrical  
Code  
LEGEND  
EQUIP — Equipment  
GND  
NEC  
TB  
— Ground  
a48-8466  
FIELD  
WIRE  
— National Electrical Code  
Terminal Block  
Fig. 43 — Field Power Wiring Connections  
for Factory-Installed Disconnect  
Fig. 41 — Field Power Wiring Connections  
FACTORY-INSTALLED  
DISCONNECT  
HANDLE LOCATION  
FACTORY-INSTALLED  
DISCONNECT  
(HIDDEN)  
a48-8467  
Fig. 42 — Factory-Installed Disconnect Location (End of Unit Shown)  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 10 — Electrical Data, 48P2,P3,P4,P5030 Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FUSE OR  
HACR  
BRKR*  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
5
10.6  
16.7  
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
152.8/150.6 200/200  
9.6 174.0/169.8 225/200  
15.2 186.2/181.0 225/225  
22.0 201.2/194.6 250/225  
28.0 214.4/206.6 250/250  
7 1/2 24.2 / 22.0  
7.5 24.2  
10 30.8  
3
10.6  
16.7  
159.4/156.6 200/200  
9.6 180.6/175.8 225/225  
15.2 192.8/187.0 225/225  
22.0 207.8/200.6 250/250  
28.0 221.0/212.6 250/250  
10  
15  
30.8 / 28.0  
46.2 / 42.0  
59.4 / 54.0  
74.8 / 68.0  
88.0 / 80.0  
11.0  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
174.8/170.6 225/200  
9.6 196.0/189.8 225/225  
15.2 208.2/201.0 250/250  
22.0 223.2/214.6 250/250  
28.0 236.4/226.6 250/250  
5
7.5 24.2  
10 30.8  
3
6.6  
208/230  
187  
253  
1
51.3  
300  
1
51.3  
300  
2
10.6  
16.7  
190.1/183.3 225/225  
(ea)  
9.6 211.3/202.5 250/250  
15.2 223.5/213.7 250/250  
22.0 238.5/227.3 250/250  
28.0 251.7/239.3 300/250  
20  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
209.3/200.8 250/250  
9.6 230.5/220.0 300/250  
15.2 242.7/231.2 300/250  
22.0 257.7/244.8 300/300  
28.0 270.9/256.8 300/300  
25  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
225.8/215.8 300/250  
9.6 247.0/235.0 300/300  
15.2 259.2/246.2 300/300  
22.0 274.2/259.8 350/300  
28.0 287.4/271.8 350/350  
30  
5
7.5 24.2  
10 30.8  
69.6  
79.2  
84.8  
91.6  
97.6  
2
2
2
2
3
5
7.5  
10  
4.8  
7.6  
11.0  
14.0  
90  
100  
100  
110  
110  
7 1/2  
72.6  
82.2  
87.8  
94.6  
100.6  
2
2
2
2
3
5
7.5  
10  
4.8  
7.6  
11.0  
14.0  
90  
100  
110  
110  
110  
10  
15  
20  
25  
30  
14.0  
21.0  
27.0  
34.0  
40.0  
79.6  
89.2  
94.8  
101.6  
107.6  
2
2
2
2
3
5
7.5  
10  
4.8  
7.6  
11.0  
14.0  
100  
110  
110  
110  
125  
3.3  
460  
414  
508  
1
23.1  
150  
1
23.1  
150  
2
86.6  
96.2  
101.8  
108.6  
114.6  
(ea)  
2
2
2
2
3
5
7.5  
10  
4.8  
7.6  
11.0  
14.0  
110  
110  
125  
125  
125  
95.3  
104.9  
110.5  
117.3  
123.3  
2
2
2
2
3
5
7.5  
10  
4.8  
7.6  
11.0  
14.0  
125  
125  
125  
150  
150  
102.8  
112.4  
118.0  
124.8  
130.8  
2
2
2
2
3
5
7.5  
10  
4.8  
7.6  
11.0  
14.0  
125  
150  
150  
150  
150  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 10 — Electrical Data, 48P2,P3,P4,P5030 Units (cont)  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
FUSE OR  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
(ea)  
Hp  
(ea)  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
HACR  
(ea)  
(ea)  
(ea)  
BRKR*  
59.0  
66.8  
71.2  
77.0  
81.0  
70  
80  
90  
90  
100  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
7 1/2  
9.0  
61.0  
68.8  
73.2  
79.0  
83.0  
80  
80  
90  
90  
100  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
10  
11.0  
17.0  
22.0  
27.0  
32.0  
67.0  
74.8  
79.2  
85.0  
89.0  
80  
90  
90  
100  
100  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
15  
2.6  
575  
518 632  
1
19.9  
109  
1
19.9  
109  
2
72.5  
80.3  
84.7  
90.5  
94.5  
90  
100  
100  
110  
110  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
(ea)  
20  
78.8  
86.6  
91.0  
96.8  
100.8  
100  
110  
110  
110  
125  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
25  
85.0  
92.8  
97.2  
103.0  
107.0  
110  
110  
125  
125  
125  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
30  
LEGEND  
NOTE: Units use 1 (low heat) or 2 (high heat) combustion fan motors rated at  
0.3 FLA each.  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 11 — Electrical Data, 48P2,P3,P4,P5035 Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER EVAPORATOR FAN  
FAN MOTOR MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FUSE OR  
HACR  
BRKR*  
3 PH,  
60 Hz  
FLA  
(ea)  
RLA LRA  
(ea) (ea)  
RLA LRA  
(ea) (ea)  
Hp  
(ea)  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
5
10.6  
16.7  
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
163.0/160.8  
200/200  
225/225  
250/225  
250/250  
250/250  
225/200  
225/225  
250/250  
250/250  
250/250  
225/225  
250/250  
250/250  
250/250  
300/250  
250/225  
250/250  
250/250  
300/250  
300/300  
250/250  
300/250  
300/300  
300/300  
350/300  
300/300  
300/300  
350/300  
350/300  
350/350  
100  
110  
110  
125  
125  
100  
110  
110  
125  
125  
110  
110  
125  
125  
125  
110  
125  
9.6 184.2/180.0  
15.2 196.4/191.2  
22.0 211.4/204.8  
28.0 224.6/216.8  
7 1/2  
24.2 / 22.0  
7.5 24.2  
10 30.8  
3
10.6  
16.7  
169.6/166.8  
9.6 190.8/186.0  
15.2 203.0/197.2  
22.0 218.0/210.8  
28.0 231.2/222.8  
10 30.8 / 28.0  
15 46.2 / 42.0  
20 59.4 / 54.0  
25 74.8 / 68.0  
30 88.0 / 80.0  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
185.0/180.8  
9.6 206.2/200.0  
15.2 218.4/211.2  
22.0 233.4/224.8  
28.0 246.6/236.8  
5
7.5 24.2  
10 30.8  
3
6.6  
208/230 187 253  
1
55.8 340  
1
55.8 340  
2
10.6  
16.7  
199.1/192.8  
(ea)  
9.6 220.3/212.0  
15.2 232.5/223.2  
22.0 247.5/236.8  
28.0 260.7/248.8  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
218.3/209.8  
9.6 239.5/229.0  
15.2 251.7/240.2  
22.0 266.7/253.8  
28.0 279.9/265.8  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
234.8/224.8  
9.6 256.0/244.0  
15.2 268.2/255.2  
22.0 283.2/268.8  
28.0 296.4/280.8  
78.1  
5
7.5 24.2  
10 30.8  
3
5
7.5  
10  
3
/
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
87.7  
93.3  
100.1  
106.1  
81.1  
90.7  
96.3  
103.1  
109.1  
88.1  
97.7  
103.3  
110.1  
116.1  
94.2  
103.8  
109.4  
116.2  
122.2  
102.9  
112.5  
118.1  
124.9  
130.9  
110.4  
120.0  
125.6  
132.4  
7 1/2  
11.0  
14.0  
21.0  
27.0  
34.0  
40.0  
10  
5
7.5  
10  
3
15  
5
7.5  
10  
3
3.3  
460  
414 508  
1
26.9 179  
1
26.9 179  
2
(ea)  
20  
5
125  
125  
125  
125  
125  
150  
150  
150  
150  
150  
150  
150  
7.5  
10  
3
25  
5
7.5  
10  
3
5
7.5  
10  
30  
138.4  
175  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 11 — Electrical Data, 48P2,P3,P4,P5035 Units (cont)  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER EVAPORATOR FAN  
FAN MOTOR MOTOR  
POWER EXHAUST  
POWER SUPPLY  
VOLTAGE  
No. A1  
No. B1  
3 PH,  
60 Hz  
FLA  
(ea)  
RLA LRA  
(ea) (ea)  
RLA LRA  
(ea) (ea)  
Hp  
(ea)  
FUSE OR  
HACR BRKR*  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
67.5  
75.3  
79.7  
85.5  
89.5  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
90  
90  
100  
100  
110  
7 1/2  
9.0  
69.5  
77.3  
81.7  
87.5  
91.5  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
90  
100  
100  
110  
110  
10  
15  
20  
25  
30  
11.0  
17.0  
22.0  
27.0  
32.0  
75.5  
83.3  
87.7  
93.5  
97.5  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
90  
100  
110  
110  
110  
2.6  
575  
518 632  
1
23.7 132  
1
23.7 132  
2
80.5  
88.3  
92.7  
98.5  
102.5  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
100  
110  
110  
110  
125  
(ea)  
86.4  
94.2  
98.6  
104.4  
108.4  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
110  
110  
125  
125  
125  
92.6  
100.4  
104.8  
110.6  
114.6  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
110  
125  
125  
125  
125  
LEGEND  
Full Load Amps  
NOTE: Units use 1 (low heat) or 2 (high heat) combustion fan motors rated at  
0.3 FLA each.  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 12 — Electrical Data, 48P2,P3,P4,P5040 Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR  
HACR BRKR*  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
5
10.6  
16.7  
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
174.0/171.8  
225/225  
250/225  
250/250  
250/250  
250/250  
225/225  
250/250  
250/250  
250/250  
250/250  
250/225  
250/250  
250/250  
300/250  
300/300  
250/250  
250/250  
300/250  
300/300  
300/300  
300/250  
300/300  
300/300  
350/300  
350/300  
300/300  
350/300  
350/300  
350/350  
350/350  
110  
110  
125  
125  
125  
110  
125  
125  
125  
125  
110  
125  
125  
125  
150  
125  
125  
9.6 195.2/191.0  
15.2 207.4/202.2  
22.0 222.4/215.8  
28.0 235.6/227.8  
7 1/2 24.2 / 22.0  
7.5 24.2  
10 30.8  
3
10.6  
16.7  
180.6/177.8  
9.6 201.8/197.0  
15.2 214.0/208.2  
22.0 229.0/221.8  
28.0 242.2/233.8  
10  
15  
20  
25  
30  
7 1/2  
10  
15  
20  
25  
30  
30.8 / 28.0  
46.2 / 42.0  
59.4 / 54.0  
74.8 / 68.0  
88.0 / 80.0  
11.0  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
196.0/191.8  
9.6 217.2/211.0  
15.2 229.4/222.2  
22.0 244.4/235.8  
28.0 257.6/247.8  
5
7.5 24.2  
10 30.8  
3
6.6  
208/230  
187 253  
1
55.8  
340  
2
30.1  
225  
3
10.6  
16.7  
210.1/203.8  
(ea)  
9.6 231.3/223.0  
15.2 243.5/234.2  
22.0 258.5/247.8  
28.0 271.7/259.8  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
229.3/220.8  
9.6 250.5/240.0  
15.2 262.7/251.2  
22.0 277.7/264.8  
28.0 290.9/276.8  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
245.8/235.8  
9.6 267.0/255.0  
15.2 279.2/266.2  
22.0 294.2/279.8  
28.0 307.4/291.8  
87.9  
5
7.5 24.2  
10 30.8  
3
5
7.5  
10  
3
/
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
97.5  
103.1  
109.9  
115.9  
90.9  
100.5  
106.1  
112.9  
118.9  
97.9  
107.5  
113.1  
119.9  
125.9  
104.0  
113.6  
119.2  
126.0  
132.0  
112.7  
122.3  
127.9  
134.7  
140.7  
120.2  
129.8  
135.4  
142.2  
14.0  
5
7.5  
10  
3
21.0  
5
7.5  
10  
3
3.3  
460  
414 508  
1
26.9  
179  
2
16.7  
114  
3
(ea)  
27.0  
5
125  
150  
150  
125  
150  
150  
150  
150  
150  
150  
175  
175  
7.5  
10  
3
34.0  
5
7.5  
10  
3
5
7.5  
10  
40.0  
148.2  
175  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 12 — Electrical Data, 48P2,P3,P4,P5040 Units (cont)  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR  
HACR BRKR*  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
70.8  
78.6  
83.0  
88.8  
92.8  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
90  
100  
100  
110  
110  
7 1/2  
9.0  
72.8  
80.6  
85.0  
90.8  
94.8  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
90  
100  
100  
110  
110  
10  
11.0  
17.0  
22.0  
27.0  
32.0  
78.8  
86.6  
91.0  
96.8  
100.8  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
100  
110  
110  
110  
110  
15  
2.6  
575  
518 632  
1
23.7  
132  
2
12.2  
80  
3
83.8  
91.6  
96.0  
101.8  
105.8  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
100  
110  
110  
125  
125  
(ea)  
20  
89.7  
97.5  
101.9  
107.7  
111.7  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
110  
110  
125  
125  
125  
25  
95.9  
103.7  
108.1  
113.9  
117.9  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
125  
125  
125  
125  
125  
30  
LEGEND  
NOTE: Units use 1 (low heat) or 2 (high heat) combustion fan motors rated at  
0.3 FLA each.  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 13 — Electrical Data, 48P2,P3,P4,P5050 Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR  
HACR BRKR*  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
5
10.6  
16.7  
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
225.4/223.2  
250/250  
250/250  
300/300  
300/300  
300/300  
250/250  
300/250  
300/300  
300/300  
300/300  
250/250  
300/300  
300/300  
300/300  
350/300  
300/300  
300/300  
350/300  
350/350  
350/350  
350/300  
350/350  
350/350  
400/350  
400/350  
350/350  
400/350  
400/350  
400/400  
400/400  
110  
125  
125  
125  
150  
110  
125  
125  
150  
150  
125  
125  
150  
150  
150  
125  
150  
9.6 246.6/242.4  
15.2 258.8/253.6  
22.0 273.8/267.2  
28.0 287.0/279.2  
7 1/2 24.2 / 22.0  
7.5 24.2  
10 30.8  
3
10.6  
16.7  
232.0/229.2  
9.6 253.2/248.4  
15.2 265.4/259.6  
22.0 280.4/273.2  
28.0 293.6/285.2  
10  
15  
20  
25  
30  
7 1/2  
10  
15  
20  
25  
30  
30.8 / 28.0  
46.2 / 42.0  
59.4 / 54.0  
74.8 / 68.0  
88.0 / 80.0  
11.0  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
247.4/243.2  
9.6 268.6/262.4  
15.2 280.8/273.6  
22.0 295.8/287.2  
28.0 309.0/299.2  
5
7.5 24.2  
10 30.8  
3
6.6  
208/230  
187 253  
2
33.3  
239  
2
48.1  
245  
4
10.6  
16.7  
263.5/256.7  
(ea)  
9.6 284.7/275.9  
15.2 296.9/287.1  
22.0 311.9/300.7  
28.0 325.1/312.7  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
282.7/274.2  
9.6 303.9/293.4  
15.2 316.1/304.6  
22.0 331.1/318.2  
28.0 344.3/330.2  
5
7.5 24.2  
10 30.8  
3
10.6  
16.7  
299.2/289.2  
9.6 320.4/308.4  
15.2 332.6/319.6  
22.0 347.6/333.2  
28.0 360.8/345.2  
101.9  
5
7.5 24.2  
10 30.8  
3
5
7.5  
10  
3
/
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
4.8  
7.6  
11.0  
14.0  
111.5  
117.1  
123.9  
129.9  
104.9  
114.5  
120.1  
126.9  
132.9  
112.5  
122.1  
127.7  
134.5  
140.5  
120.0  
129.6  
135.2  
142.0  
148.0  
128.7  
138.3  
143.9  
150.7  
156.7  
136.2  
145.8  
151.4  
158.2  
14.0  
5
7.5  
10  
3
21.0  
5
7.5  
10  
3
3.3  
460  
414 508  
2
17.9  
125  
2
18.6  
125  
4
(ea)  
27.0  
5
150  
150  
150  
150  
150  
175  
175  
175  
175  
175  
175  
175  
7.5  
10  
3
34.0  
5
7.5  
10  
3
5
7.5  
10  
40.0  
164.2  
200  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 13 — Electrical Data, 48P2,P3,P4,P5050 Units (cont)  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR  
HACR BRKR*  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
78.1  
85.9  
90.3  
96.1  
100.1  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
90  
100  
100  
110  
110  
7 1/2  
9.0  
80.1  
87.9  
92.3  
98.1  
102.1  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
90  
100  
100  
110  
110  
10  
11.0  
17.0  
22.0  
27.0  
32.0  
86.7  
94.5  
98.9  
104.7  
108.7  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
100  
110  
110  
110  
125  
15  
2.6  
575  
518 632  
2
12.8  
80  
2
14.7  
100  
4
92.9  
100.7  
105.1  
110.9  
114.9  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
110  
110  
125  
125  
125  
(ea)  
20  
99.2  
107.0  
111.4  
117.2  
121.2  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
125  
125  
125  
125  
125  
25  
105.4  
113.2  
117.6  
123.4  
127.4  
2
2
2
2
3
5
7.5  
10  
3.9  
6.1  
9.0  
11.0  
125  
125  
125  
150  
150  
30  
LEGEND  
NOTE: Units use 1 (low heat) or 2 (high heat) combustion fan motors rated at  
0.3 FLA each.  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 14 — Electrical Data, 48P2,P3,P4,P5055 Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER EVAPORATOR  
FAN MOTOR FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
/
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR  
HACR BRKR*  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
277.0/272.8  
300/300  
350/350  
350/350  
350/350  
350/300  
350/350  
400/350  
400/350  
350/350  
400/400  
400/400  
400/400  
400/350  
450/400  
450/400  
450/450  
450/450  
500/450  
500/450  
500/500  
125  
150  
150  
150  
125  
150  
150  
175  
150  
175  
175  
175  
175  
175  
175  
200  
200  
200  
225  
225  
100  
110  
125  
125  
110  
125  
125  
125  
125  
125  
125  
150  
125  
150  
150  
150  
150  
150  
175  
175  
5.0 16.7 / 15.2 310.4/303.2  
7.5 24.2 / 22.0 325.4/316.8  
10.0 30.8 / 28.0 338.6/328.8  
15  
20  
25  
30  
46.2/42.0  
/
293.1/286.3  
5.0 16.7 / 15.2 326.5/316.7  
7.5 24.2 / 22.0 341.5/330.3  
10.0 30.8 / 28.0 354.7/342.3  
59.4/54.0  
74.8/68.0  
88.0/80.0  
/
312.3/303.8  
6.6  
5.0 16.7 / 15.2 345.7/334.2  
7.5 24.2 / 22.0 360.7/347.8  
10.0 30.8 / 28.0 373.9/359.8  
208/230  
187 253  
414 508  
518 632  
2
2
2
48.1  
245  
2
48.1  
245  
4
(ea)  
/
328.8/318.8  
5.0 16.7 / 15.2 362.2/349.2  
7.5 24.2 / 22.0 377.2/362.8  
10.0 30.8 / 28.0 390.4/374.8  
/
361.3/348.8  
5.0 16.7 / 15.2 394.7/379.2  
7.5 24.2 / 22.0 409.7/392.8  
10.0 30.8 / 28.0 422.9/404.8  
40 114.0/104.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
113.9  
129.1  
135.9  
141.9  
121.4  
136.6  
143.4  
149.4  
130.1  
145.3  
152.1  
158.1  
137.6  
152.8  
159.6  
165.6  
152.6  
167.8  
174.6  
180.6  
90.5  
15  
20  
25  
30  
40  
15  
20  
25  
30  
40  
21.0  
27.0  
34.0  
40.0  
52.0  
17.0  
22.0  
27.0  
32.0  
41.0  
3.3  
460  
18.6  
125  
2
18.6  
125  
4
(ea)  
102.7  
108.5  
112.5  
96.7  
2
2
2
2
2
2
2
2
2
2
2
2
108.9  
114.7  
118.7  
103.0  
115.2  
121.0  
125.0  
109.2  
121.4  
127.2  
131.2  
120.5  
132.7  
138.5  
142.5  
2.6  
575  
14.7  
100  
2
14.7  
100  
4
(ea)  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
2
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 15 — Electrical Data, 48P2,P3,P4,P5060 Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER EVAPORATOR  
FAN MOTOR FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
/
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR  
HACR BRKR*  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
290.6/286.4  
300/300  
350/350  
350/350  
400/350  
350/350  
350/350  
400/350  
400/400  
350/350  
400/400  
400/400  
450/400  
400/400  
450/400  
450/450  
450/450  
450/450  
500/450  
500/500  
500/500  
150  
150  
175  
175  
150  
175  
175  
175  
175  
175  
200  
200  
175  
200  
200  
200  
200  
225  
225  
250  
125  
125  
150  
150  
125  
150  
150  
150  
150  
150  
150  
150  
150  
150  
175  
175  
175  
175  
200  
200  
5.0 16.7 / 15.2 324.0/316.8  
7.5 24.2 / 22.0 339.0/330.4  
10.0 30.8 / 28.0 352.2/342.4  
15  
20  
25  
30  
46.2/42.0  
/
305.9/299.1  
5.0 16.7 / 15.2 339.3/329.5  
7.5 24.2 / 22.0 354.3/343.1  
10.0 30.8 / 28.0 367.5/355.1  
59.4/54.0  
74.8/68.0  
88.0/80.0  
/
325.1/316.6  
6.6  
5.0 16.7 / 15.2 358.5/347.0  
7.5 24.2 / 22.0 373.5/360.6  
10.0 30.8 / 28.0 386.7/372.6  
208/230  
187 253  
414 508  
518 632  
2
2
2
51.3  
300  
2
51.3  
300  
4
(ea)  
/
341.6/331.6  
5.0 16.7 / 15.2 375.0/362.0  
7.5 24.2 / 22.0 390.0/375.6  
10.0 30.8 / 28.0 403.2/387.6  
/
374.1/361.6  
5.0 16.7 / 15.2 407.5/392.0  
7.5 24.2 / 22.0 422.5/405.6  
10.0 30.8 / 28.0 435.7/417.6  
40 114.0/104.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
132.4  
147.6  
154.4  
160.4  
139.4  
154.6  
161.4  
167.4  
148.1  
163.3  
170.1  
176.1  
155.6  
170.8  
177.6  
183.6  
170.6  
185.8  
192.6  
198.6  
112.0  
124.2  
130.0  
134.0  
117.5  
129.7  
135.5  
139.5  
123.8  
136.0  
141.8  
145.8  
130.0  
142.2  
148.0  
152.0  
141.3  
153.5  
159.3  
163.3  
15  
20  
25  
30  
40  
15  
20  
25  
30  
40  
21.0  
27.0  
34.0  
40.0  
52.0  
17.0  
22.0  
27.0  
32.0  
41.0  
3.3  
460  
23.1  
150  
2
23.1  
150  
4
(ea)  
2
2
2
2
2
2
2
2
2
2
2
2
2.6  
575  
19.9  
109  
2
19.9  
109  
4
(ea)  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
2
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 16 — Electrical Data, 48P2,P3,P4,P5070 Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER EVAPORATOR  
FAN MOTOR FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR  
HACR BRKR*  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
300.8/ 296.6  
350/350  
350/350  
400/350  
400/400  
350/350  
400/350  
400/400  
400/400  
400/350  
400/400  
450/400  
450/400  
400/400  
450/450  
450/450  
500/450  
450/450  
500/500  
500/500  
500/500  
150  
175  
175  
175  
150  
175  
175  
200  
175  
200  
200  
200  
200  
200  
225  
225  
225  
225  
250  
250  
125  
150  
150  
150  
150  
150  
150  
150  
150  
150  
175  
175  
150  
175  
175  
175  
175  
200  
200  
200  
5.0 16.7  
7.5 24.2  
10.0 30.8  
15.2 334.2/ 327.0  
22.0 349.2/ 340.6  
28.0 362.4/ 352.6  
15  
20  
25  
30  
46.2/42.0  
314.9/ 308.6  
5.0 16.7  
7.5 24.2  
10.0 30.8  
15.2 348.3/ 339.0  
22.0 363.3/ 352.6  
28.0 376.5/ 364.6  
59.4/54.0  
74.8/68.0  
88.0/80.0  
334.1/ 325.6  
6.6  
5.0 16.7  
7.5 24.2  
10.0 30.8  
15.2 367.5/ 356.0  
22.0 382.5/ 369.6  
28.0 395.7/ 381.6  
208/230  
187 253  
414 508  
518 632  
2
2
2
51.3  
300  
2
55.8  
340  
4
(ea)  
350.6/ 340.6  
5.0 16.7  
7.5 24.2  
10.0 30.8  
15.2 384.0/ 371.0  
22.0 399.0/ 384.6  
28.0 412.2/ 396.6  
383.1/ 370.6  
5.0 16.7  
7.5 24.2  
10.0 30.8  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
/
/
/
15.2 416.5/ 401.0  
22.0 431.5/ 414.6  
28.0 444.7/ 426.6  
140.9  
40 114.0/104.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
156.1  
162.9  
168.9  
147.0  
162.2  
169.0  
175.0  
155.7  
170.9  
177.7  
183.7  
163.2  
178.4  
185.2  
191.2  
178.2  
193.4  
200.2  
206.2  
120.5  
132.7  
138.5  
142.5  
125.5  
137.7  
143.5  
147.5  
131.4  
143.6  
149.4  
153.4  
137.6  
15  
20  
25  
30  
40  
15  
20  
25  
30  
40  
21.0  
27.0  
34.0  
40.0  
52.0  
17.0  
22.0  
27.0  
32.0  
41.0  
3.3  
460  
23.1  
150  
2
26.9  
179  
4
(ea)  
2
2
2
2
2
2
2
2
2
2
2
2
2.6  
575  
19.9  
109  
2
23.7  
132  
4
(ea)  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
149.8  
155.6  
159.6  
148.9  
161.1  
166.9  
170.9  
2
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 17 — Electrical Data — 48P2,P3,P4,P5075 Standard Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER  
POWER SUPPLY  
No. A1,A2  
No. B1,B2  
EXHAUST  
VOLTAGE  
3 PH, 60 Hz  
RLA LRA  
RLA LRA  
Hp  
FLA  
(ea)  
FUSE OR  
HACR BRKR*  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
(ea)  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
170.8  
186.0  
192.8  
198.8  
185.8  
201.0  
207.8  
213.8  
202.1  
217.3  
224.1  
230.1  
217.1  
232.3  
239.1  
245.1  
240.8  
256.0  
262.8  
268.8  
145.2  
157.4  
163.2  
167.2  
156.5  
168.7  
174.5  
178.5  
170.2  
182.4  
188.2  
192.2  
182.7  
194.9  
200.7  
204.7  
201.5  
213.7  
219.5  
223.5  
200  
225  
225  
225  
225  
250  
250  
250  
250  
250  
250  
250  
250  
300  
300  
300  
300  
350  
350  
350  
175  
175  
175  
175  
175  
200  
200  
200  
200  
225  
225  
225  
225  
250  
250  
250  
250  
250  
250  
300  
30  
40  
50  
60  
75  
30  
40  
50  
60  
75  
40.0  
52.0  
65.0  
77.0  
96.0  
32.0  
41.0  
52.0  
62.0  
77.0  
3.3  
460  
414 508  
2
26.9  
179  
2
26.9  
179  
4
(ea)  
2.6  
575  
518 632  
2
23.7  
132  
2
23.7  
132  
4
(ea)  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
2
2
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 18 — Electrical Data — 48P2,P3,P4,P5075 Units with Optional High-Capacity Power Exhaust  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER  
POWER SUPPLY  
No. A1,A2  
No. B1,B2  
EXHAUST  
VOLTAGE  
3 PH, 60 Hz  
RLA LRA  
RLA LRA  
Hp  
FLA  
(ea)  
FUSE OR  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
(ea)  
HACR BRKR*  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
198.8  
212.8  
224.8  
238.8  
250.8  
213.8  
227.8  
239.8  
253.8  
265.8  
230.1  
244.1  
256.1  
270.1  
282.1  
245.1  
259.1  
271.1  
285.1  
297.1  
268.8  
282.8  
294.8  
308.8  
320.8  
167.2  
179.2  
189.2  
199.2  
209.2  
178.5  
190.5  
200.5  
210.5  
220.5  
192.2  
204.2  
214.2  
224.2  
234.2  
204.7  
216.7  
226.7  
236.7  
246.7  
223.5  
235.5  
245.5  
255.5  
265.5  
225  
250  
250  
250  
300  
250  
250  
250  
300  
300  
250  
300  
300  
300  
300  
300  
300  
300  
350  
350  
350  
350  
350  
400  
400  
175  
200  
200  
225  
225  
200  
225  
225  
250  
250  
225  
250  
250  
250  
250  
250  
250  
250  
250  
300  
300  
300  
300  
300  
300  
30  
40  
50  
60  
75  
30  
40  
50  
60  
75  
40.0  
52.0  
65.0  
77.0  
96.0  
32.0  
41.0  
52.0  
62.0  
77.0  
3.3  
460  
414 508  
2
26.9  
179  
2
26.9  
179  
4
(ea)  
2.6  
575  
518 632  
2
23.7  
132  
2
23.7  
132  
4
(ea)  
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 19 — Electrical Data — 48P2,P3,P4,P5075 Units with Optional Return Fan  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR HACR  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
BRKR*  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
197.8  
204.8  
210.8  
225.8  
212.8  
219.8  
225.8  
237.8  
229.1  
236.1  
242.1  
254.1  
244.1  
251.1  
257.1  
269.1  
267.8  
274.8  
280.8  
292.8  
167.2  
172.2  
177.2  
188.5  
178.5  
183.5  
188.5  
197.5  
192.2  
197.2  
202.2  
211.2  
204.7  
209.7  
214.7  
223.7  
223.5  
228.5  
233.5  
242.5  
225  
225  
250  
250  
250  
250  
250  
250  
250  
300  
300  
300  
300  
300  
300  
300  
350  
350  
350  
350  
175  
200  
200  
225  
200  
200  
225  
225  
225  
225  
250  
250  
250  
250  
250  
250  
300  
300  
300  
300  
30  
40  
50  
60  
75  
30  
40  
50  
60  
75  
40.0  
52.0  
65.0  
77.0  
96.0  
32.0  
41.0  
52.0  
62.0  
77.0  
3.3  
460  
414 508  
2
26.9  
179  
2
26.9  
179  
4
(ea)  
2.6  
575  
518 632  
2
23.7  
132  
2
23.7  
132  
4
(ea)  
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 20 — Electrical Data — 48P2,P3,P4,P5090 Standard Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR HACR  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
BRKR*  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
5
7.5  
10.0  
5
7.5  
10  
5
7.5  
10  
5
7.5  
10  
5
7.5  
10  
5
7.5  
10.0  
5
7.5  
10  
5
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
208.4  
223.6  
230.4  
236.4  
223.4  
238.6  
245.4  
251.4  
239.7  
254.9  
261.7  
267.7  
254.7  
269.9  
276.7  
282.7  
278.4  
293.6  
300.4  
306.4  
175.0  
187.2  
193.0  
197.0  
186.3  
198.5  
204.3  
208.3  
200.0  
212.2  
218.0  
222.0  
212.5  
224.7  
230.5  
234.5  
231.3  
243.5  
249.3  
253.3  
225  
250  
250  
250  
250  
250  
250  
300  
300  
300  
300  
300  
300  
300  
350  
350  
350  
350  
350  
400  
200  
200  
200  
225  
225  
225  
225  
225  
250  
250  
250  
250  
250  
250  
250  
250  
300  
300  
300  
300  
30  
40  
50  
60  
75  
30  
40  
50  
60  
75  
40.0  
52.0  
65.0  
77.0  
96.0  
32.0  
41.0  
52.0  
62.0  
77.0  
3.3  
460  
414 508  
3
23.1  
150  
3
23.1  
150  
6
(ea)  
2.6  
575  
518 632  
3
19.9  
109  
3
19.9  
109  
6
7.5  
10  
5
7.5  
10  
5
(ea)  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
2
2
7.5  
10  
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 21 — Electrical Data — 48P2,P3,P4,P5090 Units with Optional High-Capacity Power Exhaust  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR HACR  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
BRKR*  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
236.4  
250.4  
262.4  
276.4  
288.4  
251.4  
265.4  
277.4  
291.4  
303.4  
267.7  
281.7  
293.7  
307.7  
319.7  
282.7  
296.7  
308.7  
322.7  
334.7  
306.4  
320.4  
332.4  
346.4  
358.4  
197.0  
209.0  
219.0  
229.0  
239.0  
208.3  
220.3  
230.3  
240.3  
250.3  
222.0  
234.0  
244.0  
254.0  
264.0  
234.5  
246.5  
256.5  
266.5  
276.5  
253.3  
265.3  
275.3  
285.3  
295.3  
250  
300  
300  
300  
300  
300  
300  
300  
300  
350  
300  
300  
350  
350  
350  
350  
350  
350  
350  
400  
400  
400  
400  
400  
450  
225  
225  
250  
250  
250  
225  
250  
250  
250  
300  
250  
250  
250  
300  
300  
250  
300  
300  
300  
300  
300  
300  
350  
350  
350  
30  
40  
50  
60  
75  
30  
40  
50  
60  
75  
40.0  
52.0  
65.0  
77.0  
96.0  
32.0  
41.0  
52.0  
62.0  
77.0  
3.3  
460  
414 508  
3
23.1  
150  
3
23.1  
150  
6
(ea)  
2.6  
575  
518 632  
3
19.9  
109  
3
19.9  
109  
6
(ea)  
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 22 — Electrical Data — 48P2,P3,P4,P5090 Units with Optional Return Fan  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR HACR  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
BRKR*  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
235.4  
242.4  
248.4  
263.4  
250.4  
257.4  
263.4  
275.4  
266.7  
273.7  
279.7  
291.7  
281.7  
288.7  
294.7  
306.7  
305.4  
312.4  
318.4  
330.4  
197.0  
202.0  
207.0  
218.3  
208.3  
213.3  
218.3  
227.3  
222.0  
227.0  
232.0  
241.0  
234.5  
239.5  
244.5  
253.5  
253.3  
258.3  
263.3  
272.3  
250  
250  
250  
300  
300  
300  
300  
300  
300  
300  
300  
350  
350  
350  
350  
350  
400  
400  
400  
400  
225  
225  
225  
250  
225  
250  
250  
250  
250  
250  
250  
250  
250  
300  
300  
300  
300  
300  
300  
300  
30  
40  
50  
60  
75  
30  
40  
50  
60  
75  
40.0  
52.0  
65.0  
77.0  
96.0  
32.0  
41.0  
52.0  
62.0  
77.0  
3.3  
460  
414 508  
3
23.1  
150  
3
23.1  
150  
6
(ea)  
2.6  
575  
518 632  
3
19.9  
109  
3
19.9  
109  
6
(ea)  
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 23 — Electrical Data — 48P2,P3,P4,P5100 Standard Units  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR HACR  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
BRKR*  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
7.6  
11.0  
14.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
219.8  
235.0  
241.8  
247.8  
234.8  
250.0  
256.8  
262.8  
251.1  
266.3  
273.1  
279.1  
266.1  
281.3  
288.1  
294.1  
289.8  
305.0  
311.8  
317.8  
186.4  
198.6  
204.4  
208.4  
197.7  
209.9  
215.7  
219.7  
211.4  
223.6  
229.4  
233.4  
223.9  
236.1  
241.9  
245.9  
242.7  
254.9  
260.7  
264.7  
250  
250  
250  
250  
250  
300  
300  
300  
300  
300  
300  
300  
300  
350  
350  
350  
350  
400  
400  
400  
200  
225  
225  
225  
225  
250  
250  
250  
250  
250  
250  
250  
250  
250  
300  
300  
300  
300  
300  
300  
30  
40  
50  
60  
75  
30  
40  
50  
60  
75  
40.0  
52.0  
65.0  
77.0  
96.0  
32.0  
41.0  
52.0  
62.0  
77.0  
3.3  
460  
414 508  
3
23.1  
150  
3
26.9  
179  
6
(ea)  
2.6  
575  
518 632  
3
19.9  
109  
3
23.7  
132  
6
(ea)  
5.0  
7.5  
10.0  
5.0  
7.5  
10.0  
6.1  
9.0  
11.0  
6.1  
9.0  
11.0  
2
2
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 24 — Electrical Data — 48P2,P3,P4,P5100 Units with Optional High-Capacity Power Exhaust  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR HACR  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
BRKR*  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
14.0  
21.0  
27.0  
34.0  
40.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
11.0  
17.0  
22.0  
27.0  
32.0  
247.8  
261.8  
273.8  
287.8  
299.8  
262.8  
276.8  
288.8  
302.8  
314.8  
279.1  
293.1  
305.1  
319.1  
331.1  
294.1  
308.1  
320.1  
334.1  
346.1  
317.8  
331.8  
343.8  
357.8  
369.8  
208.4  
220.4  
230.4  
240.4  
250.4  
219.7  
231.7  
241.7  
251.7  
261.7  
233.4  
245.4  
255.4  
265.4  
275.4  
245.9  
257.9  
267.9  
277.9  
287.9  
264.7  
276.7  
286.7  
296.7  
306.7  
250  
300  
300  
300  
300  
300  
300  
300  
350  
350  
300  
350  
350  
350  
350  
350  
350  
350  
400  
400  
400  
400  
400  
450  
450  
225  
250  
250  
250  
300  
250  
250  
250  
300  
300  
250  
250  
300  
300  
300  
300  
300  
300  
300  
300  
300  
350  
350  
350  
350  
30  
40  
50  
60  
75  
30  
40  
50  
60  
75  
40.0  
52.0  
65.0  
77.0  
96.0  
32.0  
41.0  
52.0  
62.0  
77.0  
3.3  
460  
414 508  
3
23.1  
150  
3
26.9  
179  
6
(ea)  
2.6  
575  
518 632  
3
19.9  
109  
3
23.7  
132  
6
(ea)  
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 25 — Electrical Data — 48P2,P3,P4,P5100 Units with Optional Return Fan  
COMPRESSOR  
VOLTAGE  
RANGE  
CONDENSER  
FAN MOTOR  
EVAPORATOR  
FAN MOTOR  
POWER EXHAUST  
POWER SUPPLY  
No. A1  
No. B1  
VOLTAGE  
FLA  
(ea)  
RLA LRA  
RLA LRA  
Hp  
(ea)  
FUSE OR HACR  
3 PH, 60 Hz  
Min Max Qty  
Qty  
Qty  
FLA  
Hp  
FLA  
Qty  
MCA  
(ea)  
(ea)  
(ea)  
(ea)  
BRKR*  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
20  
25  
30  
40  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
27.0  
34.0  
40.0  
52.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
22.0  
27.0  
32.0  
41.0  
246.8  
253.8  
259.8  
274.8  
261.8  
268.8  
274.8  
286.8  
278.1  
285.1  
291.1  
303.1  
293.1  
300.1  
306.1  
318.1  
316.8  
323.8  
329.8  
341.8  
208.4  
213.4  
218.4  
229.7  
219.7  
224.7  
229.7  
238.7  
233.4  
238.4  
243.4  
252.4  
245.9  
250.9  
255.9  
264.9  
264.7  
269.7  
274.7  
283.7  
250  
300  
300  
300  
300  
300  
300  
300  
300  
350  
350  
350  
350  
350  
350  
350  
400  
400  
400  
400  
225  
225  
250  
250  
250  
250  
250  
250  
250  
250  
250  
300  
300  
300  
300  
300  
300  
300  
350  
350  
30  
40  
50  
60  
75  
30  
40  
50  
60  
75  
40.0  
52.0  
65.0  
77.0  
96.0  
32.0  
41.0  
52.0  
62.0  
77.0  
3.3  
460  
414 508  
3
23.1  
150  
3
26.9  
179  
6
(ea)  
2.6  
575  
518 632  
3
19.9  
109  
3
23.7  
132  
6
(ea)  
LEGEND  
FLA  
HACR  
Hp  
LRA  
MCA  
RLA  
Full Load Amps  
Heating, Air Conditioning, and Refrigeration  
Nominal Horsepower  
Locked Rotor Amps  
Minimum Circuit Amps (for wire sizing)  
Rated Load Amps  
* Used to determine minimum disconnect per NEC (National Electrical Code).  
NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan motors rated at  
0.3 FLA each.  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
area near the entrance lobby (or other appropriate and sensitive  
location) so that location is controlled as closely to design pres-  
sures as possible.  
These units use a pressure transducer for sensing building  
pressure. The BP transducer is located in the unit auxiliary con-  
trol box. See Fig. 44 and 45 for auxiliary control box location.  
See Fig. 46 and 47 for auxiliary control box details. Use a nom-  
inal 1/4-in. plastic tubing.  
Step 13 — Connect Air Pressure Tubing — Be-  
fore options such as the variable frequency drive (VFD) and/or  
modulating power exhaust can operate properly, the pneumatic  
tubing for pressure sensing must be installed. Use fire-retardant  
1
plenum tubing (field-supplied). All control devices use /4-in.  
tubing. Tubing must be run from the appropriate sensing loca-  
tion (in the duct or in the building space) to the control device  
location in the unit.  
VARIABLE FREQUENCY DRIVE — The tubing for the  
duct pressure (DP) control option should sample supply duct  
pressure approximately 2/3 of the way out from the unit in the  
main trunk duct, at a location where a constant duct pressure is  
desired.  
On these units, the duct pressure is sensed by a pressure  
transducer. The pressure transducer output is directed to the unit  
control module. On all sizes, the DP transducer is located in the  
unit auxiliary control box. See Fig. 44 and 45 for auxiliary  
control box location. See Fig. 46-48 for auxiliary control box  
details. Use a nominal 1/4-in. plastic tubing.  
Refer to appropriate base unit Controls and Troubleshooting  
book for instructions on adjusting set points for duct pressure  
controls.  
MODULATING POWER EXHAUST — The tubing for the  
building pressure (BP) control (achieved via the modulating  
power exhaust option) should sample building pressure in the  
For instructions on adjusting BP control set points, refer to  
the Controls and Troubleshooting book.  
RETURN FAN POWER EXHAUST — The tubing for the  
building pressure (BP) control (achieved via the return power  
exhaust option) should sample building pressure in the area  
near the entrance lobby (or other appropriate and sensitive lo-  
cation) so that location is controlled as closely to design pres-  
sures as possible.  
The units use a pressure transducer for sensing building  
pressure. The BP transducer is located in the unit auxiliary con-  
trol box. See Fig. 45 for auxiliary control box location. See  
Fig. 48 for auxiliary control box details. Use a nominal 1/4 in.  
plastic tubing.  
For instructions on adjusting BP control set points, refer to  
the Controls and Troubleshooting book.  
AUXILIARY  
CONTROL  
BOX  
Fig. 44 — Auxiliary Control Box Location (Sizes 030-050)  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUXILIARY  
CONTROL  
BOX  
Fig. 45 — Auxiliary Control Box Location (Sizes 055-100)  
FS  
DP  
BP  
FS  
DP  
OACFM  
TRANSDUCER  
BP  
OACFM  
TRANSDUCER  
LEGEND  
LEGEND  
BP  
DP  
FS  
Building Pressure Transducer  
Duct Pressure Transducer  
Filter Switch  
BP  
DP  
FS  
Building Pressure Transducer  
Duct Pressure Transducer  
Filter Switch  
OACFM — Outdoor Air Cfm Sensor Transducer  
OACFM — Outdoor Air Cfm Sensor Transducer  
Fig. 46 — Auxiliary Control Box Details  
(Sizes 030-050)  
Fig. 47 — Auxiliary Control Box Details  
(Sizes 055-100 without Optional Return Fan)  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS  
DP  
BP  
OACFM  
TRANSDUCER  
RF  
CFM  
PP  
SS  
Fig. 49 — Shipping Brackets; Size 030-050 Units  
LEGEND  
Building Pressure OACFM — Outdoor Air Cfm  
BP  
DP  
FS  
Transducer  
Duct Pressure  
Transducer  
Filter Switch  
Sensor Transducer  
Plenum Pressure  
Safety Switch  
PPSS  
RFCFM — Return Fan Cfm Sensor Transducer  
Fig. 48 — Auxiliary Control Box Details  
(Size 075-100 Units with Optional Return Fan)  
Step 14 — Remove Supply-Fan Shipping  
Brackets — Supply-fan shipping brackets (4 per unit) must  
be removed from each corner of the fan sled before starting  
unit.  
UNIT SIZES 030-050  
1. To remove brackets, raise fan sled by turning adjusting  
bolt counterclockwise until spring is compressed slightly.  
2. Remove screws holding shipping bracket to unit cross  
rail.  
3. Remove shipping bracket (top of bracket is slotted so that  
it will slide out).  
4. After removing all shipping brackets, level fan sled using  
the adjusting screws. On all 4 corners, dimension from  
cross rail to fan sled should be as shown in Fig. 49.  
UNIT SIZES 055-070 — To remove shipping brackets, re-  
move the 6 screws holding each bracket to the cross rail. There  
are 8 brackets per unit. See Fig. 50.  
After removing all shipping brackets, level fan sled using  
the adjusting screws. On all 4 corners dimension from cross  
rail to fan sled should be as shown in Fig. 50.  
UNIT SIZES 075-100 — To remove shipping brackets, re-  
move the 6 screws holding each bracket to the cross rail. There  
are 4 brackets per unit. See Fig. 51.  
After removing all shipping brackets, level fan sled using  
the adjusting screws. On all 4 corners dimension from cross  
rail to fan sled should be as shown in Fig. 51.  
Fig. 50 — Shipping Brackets;  
Size 055-070 Units  
Step 15 — Remove Optional Return-Fan Ship-  
ping Brackets — Optional return fan shipping brackets  
must be removed from each corner of the fan sled before start-  
ing unit.  
To remove shipping brackets, remove 2 screws holding  
each bracket to the cross rail. There are 4 brackets per unit.  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8468  
Fig. 51 — Shipping Brackets (Sizes 075-100)  
After removing all shipping brackets, level the fan using the  
adjustment screws. On all 4 corners the dimension from cross  
rail to fan sled should be as shown in Fig. 52.  
Step 16 — Connect Gas Piping — Unit is  
equipped for use with natural gas only. Installation must con-  
form with local building codes, or in the absence of local  
codes, with the National Fuel Gas Code (NFGC), ANSI  
Z223.1.  
A 1/8-in. NPT tapping plug, accessible for test gage connec-  
tion, must be field installed immediately upstream of gas sup-  
ply connection to unit, but after manual gas valve. See Fig. 53.  
Natural gas pressure at unit gas connection must not be less  
than 5 in. wg or greater than 13 in. wg.  
Size gas supply piping for 0.5 in. wg maximum pressure  
drop. Do not use supply pipe smaller than unit gas connection.  
CAUTION  
Disconnect gas piping from unit when leak testing at pres-  
sures greater than 0.5 psig. Pressures greater than 0.5 psig  
will cause gas valve damage resulting in a hazardous con-  
dition. If gas valve is subjected to pressure greater than  
0.5 psig, it must be replaced.  
Step 17 — Configure Optional Staged Gas  
or Modulating Gas Control — The 48P Series large  
rooftop units may be ordered with an optional factory-installed  
staged gas or modulating gas control system that monitors  
heating operation of the rooftop.  
Refer to the Unit Controls and Troubleshooting book for in-  
formation on configuring staged gas or modulating gas control.  
NOTE: All dimensions are in inches.  
Fig. 52 — Optional Return  
Fan Shipping Brackets  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
together with screw provided. Refer to Table 26 for  
usage.  
4. Install flue deflector hood assembly over each flue outlet  
hood. See Fig. 64. Observe the offset mounting hole loca-  
tions in the deflector hood flanges when attaching hood to  
panel. Holes in the mounting flange must be at the bottom  
when attached.  
5. Inlet hoods are shipped unassembled and must be assem-  
bled on the access panel (see Fig. 65-67). Flanges of the  
hood top and sides should be installed on the inside of the  
access panel openings with the screws provided. The  
sides should be placed on the inside of top hoods for all  
hood assemblies (6-in., 14-in., and 30-in.). Attach speed  
clips to screen. Insert screen into bottom opening of 6-in.  
and 14-in. hoods and secure it with 3 screws. To ease the  
installation, the 30-in. hood screen may be inserted from  
inside of access panel (gas section door) into bottom  
opening of hood. Secure with 5 screws. Attached view  
port cover over 14-in. inlet hood opening (Fig. 66). Se-  
cure with two screws.  
*NPT plug is field supplied.  
NOTE: Follow all local codes.  
Fig. 53 — Gas Piping Details  
Step 18 — Install Flue/Inlet Hoods and  
Baffles — The flue/inlet hoods and baffles are shipped in a  
package taped to the basepan in the fan section. The flue (out-  
let) hoods are pre-assembled. The flue deflector, inlet hoods,  
and baffles require assembly.  
The hoods are located on the heating section access panel as  
shown in Fig. 54 (sizes 030-050), Fig. 55 (sizes 055-100 with  
low heat and vertical supply), Fig. 56 (sizes 055-100 with low  
heat and horizontal supply), and Fig. 57 (sizes 055-100 with  
high heat). The inlet baffles are located inside the access panel  
as illustrated in Fig. 58 (sizes 030-050), Fig. 59 (sizes 055-100  
with modulating low heat and horizontal supply), and Fig. 60  
(sizes 055-100 with modulating high heat). See Table 26 for a  
list of parts used to assemble each hood and quantities of each  
hood type and baffle used with each unit.  
6. Install inlet baffle on the access panel with the screw(s)  
provided. See Fig. 68 for 14-in baffle and Fig. 69 for  
30-in baffle. Attach 14-in baffle from the outside of the  
access panel. The 30-in baffle should be installed from in-  
side of the access panel. Secure with three screws.  
Step 19 — Install Supply-Air Thermistors  
(Staged and Modulating Gas Units Only) —  
Supply-air thermistors are a field-installed, factory-provided  
component. Three supply-air thermistors are shipped with  
staged and modulating gas units inside the unit control box.  
Thermistor wires must be connected to the SGC in the unit  
control box. See Table 27. The supply-air thermistors should  
be located in the supply duct with the following criteria:  
1. Remove shipping block-offs and shipping tape from all  
openings in the access panel.  
2. Attach flue outlet hoods (see Fig. 61) to access panel us-  
ing screws provided. Hoods are placed over each com-  
bustion outlet.  
downstream of the heat exchanger cells  
equally spaced as far as possible from the heat  
exchanger cells  
a duct location where none of the supply air thermistors  
are within sight of the heat exchanger cells  
a duct location with good mixed supply air portion of the  
unit.  
3. Install flue deflector baffle inside flue deflector hood. See  
Fig 62 for V-type deflector and Fig. 63 for curve-type  
deflector. For V-type deflector, screw the baffle and hood  
14-IN.  
INLET HOOD  
FLUE HOOD AND  
FLUE DEFLECTOR  
HOOD (48 SERIES  
HIGH-HEAT ONLY)  
FLUE OUTLET  
HOOD  
14-IN.  
INLET HOOD  
FLUE HOOD  
AND FLUE  
DEFLECTOR  
HOOD  
VIEW PORT  
COVER  
FLUE HOOD AND  
DEFLECTOR  
HOOD  
14-IN. INLET  
HOOD  
14-IN.  
INLET HOOD  
6-IN. INLET  
HOOD  
a48-8470  
Fig. 54 — Flue/Inlet Hood Locations, 030-050 Units  
Fig. 55 — Flue/Inlet Hood Locations, Sizes 055-100,  
Low Heat, Vertical Supply Units  
a48-8469  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FLUE OUTLET  
HOOD  
FLUE HOOD  
AND FLUE  
DEFLECTOR  
HOOD  
6-IN. INLET  
HOOD  
30-IN. INLET  
HOOD  
INLET BAFFLE  
(14-in.)  
a48-8584  
a48-8471  
Fig. 58 — Baffle Location, 030-050 Units  
Fig. 56 — Flue/Inlet Hood Locations, Sizes 055-100,  
Low Heat, Horizontal Supply Units  
a48-8585  
30-IN. INLET  
HOOD  
FLUE OUTLET  
HOOD  
INLET BAFFLE  
(30-in.)  
FLUE HOOD  
AND FLUE  
DEFLECTOR  
HOOD  
30-IN. INLET  
HOOD  
6-IN. INLET  
HOOD  
a48-8472  
Fig. 57 — Flue/Inlet Hood Locations, Sizes 055-100,  
High Heat, Vertical and Horizontal Supply Units  
Fig. 59 — Baffle Location, Sizes 055-100,  
Modulating Low Heat, Horizontal Supply Units  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 26 — Flue Hood, Inlet Hood, and Baffle Usage  
QUANTITY USED  
HOOD OR  
BAFFLE TYPE  
PARTS LIST  
FIG. NO.  
Sizes 030-050 Sizes 030-050 Sizes 055-070 Sizes 055-070 Sizes 075-100 Sizes 075-100  
(Low Heat)  
(High Heat)  
(Low Heat)  
(High Heat)  
(Low Heat)  
(High Heat)  
Top (6-in.)  
Side (Left)  
Side (Right)  
Screen  
Speed Clips  
Screws  
6-in. Inlet  
Hood  
65  
1
1
1
1
Top (14-in.)  
Side (Left)  
Side (Right)  
Screen  
1
1
14-in. Inlet  
Hood  
65,66  
67  
3
3
(Vertical  
2
(Vertical  
2
Cover  
Supply Only)  
Supply Only)  
Speed Clips  
Screws  
Top (30-in.)  
Side (Left)  
Side (Right)  
Screen  
Speed Clips  
Screws  
1
1
30-in. Inlet  
Hood  
(Horizontal  
Supply Only)  
(Horizontal  
Supply Only)  
Flue Outlet  
Hood  
Pre-assembled  
61  
62  
1
1
2
2
2
3
3
2
2
3
3
Hood  
2
Flue Deflector  
(V-Type)  
Deflector  
Baffle  
(Horizontal  
Supply Only)  
Screws  
Hood  
2
Flue Deflector  
(Curve-Type)  
Deflector  
Baffle  
63  
68  
69  
1
2
(Vertical  
2
2
Supply Only)  
Screws  
Baffle  
Screws  
Baffle  
Screws  
14-in. Baffle  
30-in. Baffle  
1
1
(Modulating  
Horizontal  
Supply Only)  
(Modulating  
Horizontal  
Supply Only)  
Fig. 61 — Flue Outlet Hood  
FLUE DEFLECTOR  
BAFFLE  
FLUE  
DEFLECTOR  
HOOD  
PUSH  
BAFFLE  
DOWN SO  
THESE 2  
SCREW  
HOLES  
INLET BAFFLE  
(30-in.)  
ALIGN  
Fig. 60 — Baffle Locations, Sizes 055-100,  
Modulating High Heat, Vertical and  
Horizontal Supply Units  
a48-8587  
a48-8586  
Fig. 62 — Flue Deflector Baffle (V-Type)  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESS PANEL  
OPENING  
COVER  
(14-IN. HOOD ONLY)  
FLUE DEFLECTOR  
HOOD  
MAKE  
SCREW  
HOLES  
ALIGN  
FLUE DEFLECTOR  
BAFFLE (BOTH HOODS)  
a48-8588  
Fig. 63 — Flue Deflector Baffle (Curve-Type)  
HOOD  
SIDE (TYP  
BOTH SIDES)  
SCREEN  
SPEED CLIP  
(TYP 3)  
Fig. 65 — Inlet Hood Assembly (6-in. and 14-in.)  
VIEW PORT  
COVER  
OBSERVE OFFSET  
MOUNTING HOLE  
LOCATIONS WHEN  
INSTALLING FLUE  
DEFLECTOR HOODS.  
Fig. 64 — Mounting Deflector Hoods  
Fig. 66 — 14-in. Inlet Hood View Port Cover  
Installation  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INLET HOOD  
SIDE  
INLET  
HOOD  
SCREEN  
(WITH SPEED CLIPS)  
INLET HOOD  
SIDE  
a48-8473  
Fig. 67 — Inlet Hood Assembly (30-in.)  
Fig. 68 — Air Baffle (14-in.)  
a48-8590  
a48-8591  
Fig. 69 — Air Baffle (30-in.)  
Table 27 — SGC Thermistor Designations  
PIN  
FUNCTION AND LOCATION  
Thermistors  
THERMISTOR  
SAT1  
CONNECTION  
POINT  
PART NO.  
Supply-Air Thermistor (SAT) — Inserted into supply section  
underneath the gas heat section (factory-provided,  
field-installed)  
Supply-Air Thermistor (SAT) — Inserted into supply section  
underneath the gas heat section (factory-provided,  
field-installed)  
Supply-Air Thermistor (SAT) — Inserted into supply section  
underneath the gas heat section (factory-provided,  
field-installed)  
J8 – 1,2 (SGC)  
J8 – 3,4 (SGC)  
J8 – 5,6 (SGC)  
SAT2  
HH79NZ033  
SAT3  
Limit Switch Thermistor (LIMTTEMP) — Inserted next the  
lower limit switch (factory-installed)  
LIMTTEMP  
J8 – 15,16 (SGC)  
SGC — Staged Gas Controller  
Step 20 — Install Optional Motormaster®  
V
On size 040-060 units, in areas with prevailing winds of  
more than 5 mph and where temperatures drop below 32 F,  
wind baffles must be field fabricated to ensure proper cooling  
cycle operation at low-ambient temperatures with Motormaster  
V controls. Wind baffles are not needed on size 030, 035, and  
070-100 units. See Fig. 70 for baffle details. Use 20-gage galva-  
nized sheet metal, or similar corrosion-resistant material for the  
baffles. Use field-supplied screws to attach baffles to unit.  
Screws should be 1/4-in. diameter or larger. Screws should not  
be more than 1/2-inch in length. Drill required screw holes for  
mounting baffles.  
Control — The Motormaster V control is a motor speed  
control device which adjusts condenser fan motor speed in re-  
sponse to varying liquid refrigerant pressure. A properly applied  
Motormaster V control extends the operating range of air-condi-  
tioning systems and permits operation at lower outdoor ambient  
temperatures.  
The optional Motormaster V controls are factory-installed.  
Field-fabricated and installed wind baffles are also required for  
units in areas with prevailing winds of more than 5 mph and  
where temperatures drop below 32 F. The Motormaster V con-  
trol permits operation of the unit to an ambient temperature of  
–20 F. The control regulates the speed of one or two 3-phase fan  
motors depending on unit size. Replacement of the fan motor on  
most units is not necessary.  
CAUTION  
To avoid damage to refrigerant coils, electrical compo-  
nents, and wiring use extreme care when drilling screw  
holes and screwing in fasteners.  
INSTALL FIELD-FABRICATED WIND BAFFLES  
WARNING  
To avoid the possibility of electrical shock, open all discon-  
nects before installing or servicing this accessory.  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIND BAFFLE  
a48-8561  
BAFFLE INSTALLATION LOCATION (SIZES 050 AND 060 SHOWN)  
a48-8560  
DIMENSION “A”  
in.  
UNIT SIZE  
QUANTITY  
mm  
030,035  
040-060  
070-100  
Not Used  
2
Not Used  
78.125 0.125  
1984  
3
NOTE: 48/50P030, 035, and 070-100 units do not require  
baffles.  
Fig. 70 — Wind Baffle Details  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VAV CONTROL WIRING — The recommended types of  
control wiring are shown below:  
Step 21 — Install Unit Accessories — For appli-  
cations requiring accessories, the following packages are  
available:  
PART NO.  
MANUFACTURER  
All units:  
Regular Wiring  
1895  
Plenum Wiring  
barometric relief  
Alpha  
American  
Belden  
Columbia  
Manhattan  
Quabik  
A48301  
884421  
space temperature sensor  
CO2 sensor  
A21451  
8205  
D6451  
space temperature sensor with CO2 sensor  
airflow switch  
filter switch  
smoke detector  
M13402  
6130  
M64430  
SENSORS — Sensors should be wired using single twisted  
pairs of 20 AWG (American Wire Gage) conductor cable rated  
for the application, except for the T-56 accessory sensor which  
requires 3-conductor cable.  
HUMIDITY CONTROL AND HOT WATER AND  
STEAM VALVES — These devices require 20 AWG twisted  
pair conductor cables rated for the application for the 4 to  
20 mA signal.  
SPACE TEMPERATURE SENSOR (T-55) — The space tem-  
perature sensor (P/N 33ZCT55SPT), if used, is wired to termi-  
nals in the unit main control box. To connect the space temper-  
ature sensor, see Fig. 72.  
SPACE TEMPERATURE SENSOR (T-56) — The space tem-  
perature sensor (P/N 33ZCT56SPT), if used, is wired to termi-  
nals in the unit main control box. To connect the space temper-  
ature sensor, see Fig. 72.  
COMMUNICATING SPACE TEMPERATURE SENSOR  
(T-58) — The communicating space temperature sensor (P/N  
33ZCT58SPT) is wired to the Carrier Comfort Network®  
(CCN) connections on TB202.  
SPACE TEMPERATURE AVERAGING — Applications that  
require averaging using multiple space temperature sensors can  
be satisfied using either 4 or 9 sensors as shown in Fig. 73.  
NOTE: Only Carrier sensors may be used for standard T-55  
space averaging. Sensors must be used in multiples of 1, 4, and  
9 only, with total sensors wiring not to exceed 1000 ft.  
NOTE: Do not use T-56 sensors for space temperature averag-  
ing because the 5-degree offset function will not work in a  
multiple sensor application.  
All 48P2,P4 (constant volume) units:  
modulating power exhaust  
All 48P3,P5 (variable air volume) units:  
modulating power exhaust  
Refer to the individual accessory installation instructions in  
each accessory package for information on installing accessories.  
CONTROLS INSTALLATION  
Constant Volume (CV) Units — The 48P2,P4 units  
may be used in applications with additional control features,  
options, or accessories. Refer to the appropriate accessory  
installation instructions for more information on installing that  
accessory. Control options and accessories available for CV  
units are:  
• thermostats  
• enthalpy sensor  
• enthalpy switch  
• relative humidity sensor  
• CEM (controls expansion module)  
• Navigator™ hand-held display  
CONTROL WIRING — The unit can be controlled with a  
Carrier-approved accessory electro-mechanical or electronic  
thermostat that has two stages of cooling, two stages of heating  
control, and an output for fan control. The thermostat may also  
include time of day scheduling or use scheduling routines built  
into the ComfortLink™ controls.  
Install the thermostat according to the installation instruc-  
tions shipped with the accessory thermostat. Locate thermostat  
assembly on a solid interior wall to sense average temperature.  
HEAT INTERLOCK RELAY (VAV Units Only — Not Neces-  
sary for Digital Air Volume Applications) — Variable air vol-  
ume (VAV) units using morning warm-up and/or occupied  
heating require that room terminals be controlled to a position  
that provides the minimum required heating cfm or greater  
when the unit goes into Heating mode. The HIR (heat interlock  
relay) function is provided for this control. When the unit goes  
into Heating mode, the HIR is energized to provide switch clo-  
sure or opening (depending on how the field-supplied power  
source is set up) to open the room terminals. The field connec-  
tions for the HIR are at TB201 terminals 9 and 10. See Fig. 74.  
Route thermostat cable or equivalent leads of colored wire  
from subbase terminals through conduit into the low voltage  
connections in the main control box. For thermostat TB201  
connections, see Fig. 71.  
NOTE: For wire runs up to 50 ft, use no. 18 AWG (American  
Wire Gage) insulated wire (35 C minimum). For over 75 ft, use  
no. 14 AWG insulated wire (35 C minimum). All wire larger  
than no. 18 AWG cannot be directly connected at the thermostat  
and will require a junction box and splice at the thermostat.  
Variable Air Volume (VAV) Units The 48P3,P5  
units may be used in applications with additional control fea-  
tures, options, or accessories. Refer to the appropriate accesso-  
ry installation instructions for more information on installing  
that accessory. Refer to the Controls and Troubleshooting man-  
ual for more information concerning installation and configura-  
tion of options and accessories. Control options and accessories  
available for VAV units are:  
Option and Accessory Control Wiring The P  
Series units may be used in applications with additional control  
features, options, or accessories. Refer to the Controls and  
Troubleshooting manual for more information concerning  
installation and configuration of options and accessories.  
Figures 74-84 contain wiring information on the following  
features:  
• enthalpy sensor  
• heat interlock relay (Fig. 74)  
• enthalpy switch  
• outdoor air enthalpy switch (Fig. 75)  
• CO2 space sensor (Fig. 76)  
• relative humidity sensor  
• CEM (controls expansion module)  
• Navigator hand-held display  
• filter status switch (Fig. 77)  
• fan status switch (Fig. 78)  
• space humidity sensor (Fig. 79)  
• return air humidity sensor (Fig. 79)  
• return air CO2 sensor (Fig. 80)  
• return air smoke detector (Fig. 81)  
• smoke control — fire shutdown (Fig. 82)  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
• smoke control — purge (Fig. 83)  
• smoke control — evacuation (Fig. 83)  
• smoke control — pressurization (Fig. 83)  
• CCN connections (Fig. 84)  
JUMPER  
TERMINALS  
T55- SPT  
SEN  
T56- SPT  
SEN  
SET  
FIELD SUPPLIED THERMOSTAT  
11  
12  
1
2
13  
14  
3
4
5
6
9
7
8
15  
16  
RC  
Y1  
Y1  
Y2  
Y2  
W1  
W1  
W2  
W2  
G
G
R
R
UNIT  
TB201  
10  
X
C
TB201  
Fig. 72 — T55 or T56 Wiring  
a48-8474  
a48-8475  
Fig. 71 — Field Control Thermostat Wiring  
TB201  
RED  
1
BLK  
2
SENSOR 4  
SENSOR 3  
SENSOR 1  
SENSOR 2  
TB202  
1
2
SENSOR 1  
SENSOR 2  
SENSOR 3  
SENSOR 6  
SENSOR 5  
SENSOR 4  
SENSOR 9  
SENSOR 8  
SENSOR 7  
NOTE: Use T55 sensor only.  
a48-8476  
Fig. 73 — Space Temperature Averaging Wiring  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
14  
15  
RCB  
J8  
RELAY 5  
10  
9
a48-8477  
Fig. 74 — Heat Interlock Relay Wiring  
a48-8481  
6
RCB  
J4  
FIELD INSTALLED (FIELD  
SUPPLIED) JUMPER WHEN  
ENTHALPY SWITCH NOT USED  
5
a48-8478  
Fig. 75 — Outdoor Air Enthalpy Switch Wiring  
TB201  
8
MBB  
J8  
7
a48-8479  
Fig. 76 — CO2 Space Sensor Wiring  
FILTER STATUS  
MBB  
J8  
a48-8480  
Fig. 77 — Filter Status Wiring  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RCB  
J4  
Fig. 78 — Fan Status Switch Wiring  
4
3
CEM  
J6  
a48-8482  
Fig. 79 — Space and Return Air Humidity Sensor Wiring  
RED  
BRN  
a48-8483  
Fig. 80 — Return Air CO2 Sensor Wiring  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TB201  
1
2
a48-8483  
Fig. 81 — Return Air Smoke Detector Wiring  
FIRE SHUTDOWN  
2
BLU  
MBB  
J6  
1 WHT  
TB201  
a48-8485  
Fig. 82 — Fire Shutdown Wiring  
14  
15  
16  
17  
18  
19  
TB 202  
RCB J4  
a48-8486  
Fig. 83 — Purge, Evacuation, and Pressurization Wiring  
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a48-8487  
TB201  
MBB  
J5  
Fig. 84 — CCN Connections  
Carrier Comfort Network® (CCN) Interface —  
The 48P Series units can be connected to the CCN system if  
desired. The communication bus wiring is supplied and  
installed in the field. It consists of shielded, 3-conductor cable  
with shield wire.  
IMPORTANT: When connecting the CCN communica-  
tion bus to a system element, use a color coding system for  
the entire network to simplify installation and checkout.  
The following color code is recommended:  
The system elements are connected to the communication  
bus in a daisy chain arrangement. The positive pin of each  
system element communication connector must be wired to the  
positive pins of the system element on either side of it, the  
negative pins must be wired to the negative pins, and the signal  
pins must be wired to common pins. Wiring connections for  
the CCN system should be made at the terminal block using the  
screw terminals. The board also contains an RJ14 CCN plug  
that can be used to connect a field service computer. There is  
also another RJ14 LEN (Local Equipment Network) connec-  
tion that is used to download software or connect a Naviga-  
tor™ device.  
NOTE: Conductors and drain wire must be 20 AWG minimum  
stranded, tinned copper. Individual conductors must be insu-  
lated with PVC, PVC/nylon, vinyl, Teflon, or polyethylene. An  
aluminum/polyester 100% foil shield and an outer jacket of  
PVC, PVC/nylon, chrome vinyl, or Teflon with a minimum  
operating temperature range of –4 to 140 F (–20 C to 60 C) is  
required. See Table 28 for cables that meet the requirements.  
SIGNAL  
TYPE  
+
COMMON  
CCN BUS CONDUCTOR  
INSULATION COLOR  
COMM1 PLUG  
PIN NO.  
RED  
WHITE  
BLACK  
1
2
3
NOTE: If a cable with a different color scheme is selected, a  
similar color code should be adopted for the entire network.  
At each system element, the shields of its communication  
bus cables must be tied together. If the communication bus is  
entirely within one building, the resulting continuous field  
must be connected to a ground at one point only. If the commu-  
nication bus cable exits from one building and enters another,  
the shields must be connected to grounds at the lightning  
suppressor in each building where the cable enters or exits the  
building (one point per building only).  
To connect the unit to the network (Fig. 84):  
1. Turn off power to the control box.  
Table 28 — CCN Connection Approved  
Shielded Cables  
2. Cut the CCN wire and strip the ends of the red (+), white  
(common) and black (–) conductors. (If a different net-  
work color scheme is used, substitute appropriate colors.)  
3. Wire the CCN to the screw terminals on the COMM  
board as follows (Fig. 84):  
MANUFACTURER  
Alpha  
CABLE PART NO.  
2413 or 5463  
A22503  
American  
Belden  
a. Secure the red (+) wire to CCN screw terminal +  
on the COMM board.  
b. Secure the white (common) wire to CCN screw  
terminal C on the COMM board.  
8772  
Columbia  
02525  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
c. Secure the black (–) wire to CCN screw terminal –  
on the COMM board.  
using the BACview keypad/display unit, press and hold  
the “FN” key then press the “.” Key.  
d. Secure shield wire to CCN screw terminal  
SHIELD on the COMM board.  
To install a BT485 terminator, push the BT485 on to the  
BT485 connector located near the BACnet connector.  
NOTE: The BT485 terminator has no polarity associated with  
it.  
To order a BT485 terminator, consult Commercial Products  
i-Vu® Open Control System Master Prices.  
MS/TP WIRING RECOMMENDATIONS — Recommen-  
dations are shown in Tables 29 and 30. The wire jacket and UL  
temperature rating specifications list two acceptable alterna-  
tives. The Halar specification has a higher temperature rating  
and a tougher outer jacket than the SmokeGard specification,  
and it is appropriate for use in applications where the user is  
concerned about abrasion. The Halar jacket is also less likely to  
crack in extremely low temperatures.  
IMPORTANT: A shorted CCN bus cable will prevent  
some routines from running and may prevent unit from  
starting. If abnormal conditions occur, unplug the connec-  
tor. If conditions return to normal, check CCN connector,  
and run new cable if necessary. A short in one section of  
the bus can cause problems with all system elements on  
the bus.  
Optional UPC Open Installation  
WIRING THE UPC OPEN TO THE MS/TP NET-  
WORK — The UPC Open controller communicates using  
BACnet on an MS/TP network segment communications at  
9600 bps, 19.2 kbps, 38.4 kbps, or 76.8 kbps.  
Wire the controllers on an MS/TP network segment in a dai-  
sy-chain configuration. Wire specifications for the cable are  
22 AWG (American Wire Gage) or 24 AWG, low-capacitance,  
twisted, stranded, shielded copper wire. The maximum length  
is 2000 ft.  
Install a BT485 terminator on the first and last controller on  
a network segment to add bias and prevent signal distortions  
due to echoing. See Fig. 85-87.  
To wire the UPC Open controller to the BAS network:  
1. Pull the screw terminal connector from the controller's  
BAS Port.  
2. Check the communications wiring for shorts and  
grounds.  
3. Connect the communications wiring to the BAS port’s  
screw terminals labeled Net +, Net -, and Shield.  
NOTE: Use the same polarity throughout the network  
segment.  
4. Insert the power screw terminal connector into the UPC  
Open controller's power terminals if they are not current-  
ly connected.  
NOTE: Use the specified type of wire and cable for maximum  
signal integrity.  
Smoke Control Modes — Rooftop units can be used  
for aid in building smoke control in the event of a building fire.  
The available functions include: Fire Shutdown, Pressuriza-  
tion, Evacuation, and Smoke Purge. These functions are  
enhanced when multiple rooftop units are used to zone a build-  
ing. See Table 31 and Fig. 82 and 83.  
FIRE SHUTDOWN — Fire Shutdown mode terminates all  
unit operation (cooling, heating, supply fan, and power  
exhaust). This mode prevents recirculation of contaminated air  
back into the space. The mode will not allow admission into  
the space of unsuitable outside air. See Fig. 82 for wiring.  
PRESSURIZATION — Pressurization mode is intended to  
keep smoke out of a zone. The factory-installed optional econ-  
omizer is required for this function. Pressurization is accom-  
plished by the following:  
• opening the economizer (option)  
• running the supply fan (optional inlet guide vanes open  
or optional VFD at normal duct static pressure set point)  
• closing the power exhaust dampers (if installed as option  
or accessory)  
• shutting off the power exhaust fans (if installed as option  
or accessory)  
5. Verify communication with the network by viewing a  
module status report. To perform a module status report  
Table 29 — MS/TP Wiring Recommendations  
SPECIFICATION  
Cable  
Conductor  
Insulation  
Color Code  
Twist Lay  
RECOMMMENDATION  
Single twisted pair, low capacitance, CL2P, 22 AWG (7x30), TC foam FEP, plenum rated cable  
22 or 24 AWG stranded copper (tin plated)  
Foamed FEP 0.015 in. (0.381 mm) wall 0.060 in. (1.524 mm) O.D.  
Black/White  
2 in. (50.8 mm) lay on pair 6 twists/foot (20 twists/meter) nominal  
Aluminum/Mylar shield with 24 AWG TC drain wire  
Shielding  
SmokeGard Jacket (SmokeGard PVC) 0.021 in. (0.5334 mm) wall 0.175 in. (4.445 mm) O.D.  
Halar Jacket (E-CTFE) 0.010 in. (0.254 mm) wall 0.144 in. (3.6576 mm) O.D.  
Jacket  
DC Resistance  
Capacitance  
Characteristic Impedance  
Weight  
15.2 Ohms/1000 feet (50 Ohms/km) nominal  
12.5 pF/ft (41 pF/meter) nominal conductor to conductor  
100 Ohms nominal  
12 lb/1000 feet (17.9 kg/km)  
SmokeGard 167°F (75°C)  
Halar -40 to 302°F (-40 to 150°C)  
UL Temperature Rating  
Voltage  
Listing  
300 Vac, power limited  
UL: NEC CL2P, or better  
LEGEND  
AWG  
CL2P  
DC  
American Wire Gage  
Class 2 Plenum Cable  
Direct Current  
FEP  
NEC  
O.D.  
TC  
Fluorinated Ethylene Polymer  
National Electrical Code  
Outside Diameter  
Tinned Copper  
Underwriters Laboratories  
UL  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 30 — Open System Wiring Specifications and Recommended Vendors  
WIRING SPECIFICATIONS  
Description  
RECOMMENDED VENDORS AND PART NUMBERS  
Connect Air  
International  
Contractors  
Wire and Cable  
Wire Type  
Belden RMCORP  
22 AWG, single twisted shielded pair, low capacitance, CL2P,  
TC foam FEP, plenum rated. See MS/TP Installation Guide for  
specifications.  
24 AWG, single twisted shielded pair, low capacitance, CL2P,  
TC foam FEP, plenum rated. See MS/TP Installation Guide  
for specifications.  
W221P-22227  
W241P-2000F  
25160PV  
CLP0520LC  
MS/TP  
Network (RS-485)  
82841 25120-OR  
21450  
Rnet  
4 conductor, unshielded, CMP, 18 AWG, plenum rated.  
W184C-2099BLB 6302UE  
CLP0442  
LEGEND  
American Wire Gage  
Class 2 Plenum Cable  
Communications Plenum Rated  
Fluorinated Ethylene Polymer  
Tinned Copper  
AWG  
CL2P  
CMP  
FEP  
TC  
BT485  
TERMINATOR  
BACNET  
CONNECTION  
POWER LED  
Tx1 LED  
Rx1 LED  
BACNET  
BAUD RATE  
DIP SWITCHES  
Tx2 LED  
Rx2 LED  
ADDRESS  
ROTARY  
SWITCHES  
RUN LED  
ERROR LED  
Fig. 85 — UPC Open Controller  
This allows the space to be overpressurized relative to adjacent  
zones and prevents or slows entry of smoke into this space  
from adjacent zones. See Fig. 82 for wiring.  
accessory power exhaust is required for this function. Evacua-  
tion is accomplished by the following:  
• turning the supply fan off  
EVACUATION — Evacuation mode removes smoke or un-  
desirable air from interior spaces without reintroducing unsuit-  
able air. The factory-installed optional economizer with option/  
• opening the economizer (option required)  
• running the exhaust fans (option or accessory required)  
• opening the exhaust dampers.  
See Fig. 82 for wiring.  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 86 — Open System Network Wiring  
Fig. 86 — BT485 Installation  
SMOKE PURGE — Smoke Purge mode removes smoke  
Table 31 — Smoke Control Modes  
from the interior spaces and replaces it with fresh outside air.  
The factory-installed optional economizer with option/  
accessory power exhaust are required for this function. Smoke  
purge is accomplished by the following:  
MODE  
FUNCTION  
Fire  
Shutdown  
Pressur-  
ization  
Smoke  
Purge*  
On  
Open/On  
Open  
Evacuation*  
Supply Fan  
VFD†  
Economizer  
Off  
Closed  
On  
Open/On  
Open  
Off  
Open  
• turning supply fan on  
• opening the economizer (option required)  
• running the exhaust fans (option or accessory required)  
• opening the exhaust dampers  
Return Air  
Damper  
Open  
Off  
Closed  
Off  
Closed  
On  
Closed  
On  
See Fig. 82 for wiring.  
Exhaust  
Fans  
Exhaust  
Damper  
SMOKE CONTROL INSTALLATION — Implementation of  
the various smoke control modes on these units requires the in-  
staller to modify the unit wiring to add contacts (via either  
manual switches or relays) that will selectively interrupt and  
override standard factory control sequences. See Table 31 and  
Fig. 81 and 82 for more information.  
Closed  
Closed  
Open  
Open  
LEGEND  
VAV — Variable Air Volume  
VFD — Variable Frequency Drive  
*Power exhaust option required for this mode.  
†Applicable to VAV units with appropriate options.  
Copyright 2010 Carrier Corporation  
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.  
Catalog No. 04-53480079-01 Printed in U.S.A. Form 48P-4SI Pg 76 11-10 Replaces: 48P-3SI  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Waffle Iron WMB500 User Manual
BlueAnt Wireless Bluetooth Headset X5i User Manual
Bogen Stereo System RPK79 User Manual
Bolens Trimmer 52069 6HP User Manual
Bolens Trimmer HT816r User Manual
Bostitch Staple Gun 102272REVB 3 97 User Manual
Bushnell Digital Camera 119204 User Manual
Char Broil Charcoal Grill 10201600 User Manual
Chicago Electric Cordless Drill 69452 User Manual
Cisco Systems Conference Phone CP7921GAK9RF User Manual