Cabletron Systems Switch FPIM 02 User Manual

SmartSwitch 9000  
9M426-02  
User’s Guide  
9032531-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notice  
Notice  
Cabletron Systems reserves the right to make changes in specifications and other information  
contained in this document without prior notice. The reader should in all cases consult Cabletron  
Systems to determine whether any such changes have been made.  
The hardware, firmware, or software described in this manual is subject to change without notice.  
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT,  
SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED  
TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION  
CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR  
SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.  
© Copyright February 1998 by:  
Cabletron Systems, Inc.  
35 Industrial Way  
Rochester, NH 03867-5005  
All Rights Reserved  
Printed in the United States of America  
Order Number: 9032531-01  
LANVIEW is a registered trademark and SmartSwitch is a trademark of Cabletron Systems, Inc.  
i960 microprocessor is a registered trademark of Intel Corp.  
Ethernet is a trademark of Xerox Corporation.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notice  
FCC Notice  
This device complies with Part 15 of the FCC rules. Operation is subject to the following two  
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any  
interference received, including interference that may cause undesired operation.  
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated in a commercial environment.  
This equipment uses, generates, and can radiate radio frequency energy and if not installed in  
accordance with the operators manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause interference in which case the user  
will be required to correct the interference at his own expense.  
WARNING: Changes or modifications made to this device which are not expressly approved by the  
party responsible for compliance could void the users authority to operate the equipment.  
VCCI Notice  
This is a Class A product based on the standard of the Voluntary Control Council for Interference by  
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment,  
radio disturbance may arise. When such trouble occurs, the user may be required to take corrective  
actions.  
DOC Notice  
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital  
apparatus set out in the Radio Interference Regulations of the Canadian Department of  
Communications.  
Le présent appareil numérique német pas de bruits radioélectriques dépassant les limites applicables  
aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique  
édicté par le ministère des Communications du Canada.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notice  
DECLARATION OF CONFORMITY  
ADDENDUM  
Application of Council Directive(s):  
89/336/EEC  
73/23/EEC  
Manufacturer’s Name:  
Manufacturer’s Address:  
Cabletron Systems, Inc.  
35 Industrial Way  
PO Box 5005  
Rochester, NH 03867  
European Representative Name:  
European Representative Address:  
Mr. J. Solari  
Cabletron Systems Limited  
Nexus House, Newbury Business Park  
London Road, Newbury  
Berkshire RG13 2PZ, England  
Conformance to Directive(s)/Product Standards:  
Equipment Type/Environment:  
EC Directive 89/336/EEC  
EC Directive 73/23/EEC  
EN 55022  
EN 50082-1  
EN 60950  
Networking Equipment, for use in a  
Commercial or Light  
Industrial Environment.  
We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with  
this notice conforms to the above directives.  
Manufacturer  
Legal Representative in Europe  
Mr. Ronald Fotino  
____________________________________________________  
Mr. J. Solari  
______________________________________________________  
Full Name  
Full Name  
Principal Compliance Engineer  
____________________________________________________  
Managing Director - E.M.E.A.  
______________________________________________________  
Title  
Title  
Rochester, NH, USA  
____________________________________________________  
Newbury, Berkshire, England  
______________________________________________________  
Location  
Location  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notice  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Chapter 1  
Chapter 2  
Getting Help .................................................................................................................. 1-4  
Chapter 3  
Chapter 4  
Chapter 5  
Standards ......................................................................................................... 5-1  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1  
Introduction  
The 9M426-02 SmartSwitch Module shown in Figure 1-1, is a three port switch  
module with two front panel HSIM interfaces and one INB-2 backplane interface.  
With the proper HSIM, this module may be used as an ATM uplink for the  
SmartSwitch 9000 chassis.  
Features  
Processor  
The 9M426-02 is equipped with an advanced Intel i960 microprocessor. This  
microprocessor provides a platform for all management functions within a  
scalable RISC-based architecture.  
Packet Switch Engine  
The 9M426-02 module incorporates the SmartSwitch ASIC, a collection of custom  
ASlCs designed specifically for high speed switching. The SmartSwitch ASIC bus  
is 64 bits wide with a bandwidth of 320 Mbps. Since all frame translation, address  
lookups, and forwarding decisions are performed in hardware, the 9M426-02 can  
obtain a throughput performance of greater than 750K pps.  
Management  
The 9M426-02 module supports SNMP for local and remote management. Local  
management is provided through the RS-232 Com ports on the SmartSwitch 9000  
Environmental Module using a standard VT-220 terminal or emulator. Remote  
management is possible through Cabletrons SPECTRUM or any SNMP  
compliant management tool as well as telneting to the module. Management  
features including module MAC placement, front panel/ FNB configuration, and  
SMT statistics. Switching statistics on both HSIM interfaces provide frames  
filtered, frames forwarded, and all Spanning Tree Protocol parameters. The  
9M426-02 module supports the IETF MIB ll (RFC-1213), IETF BRIDGE MIB  
(RFC-1493), and a host of Cabletron enterprise MIBs. In addition, the front panel  
provides LEDs for transmit and receive activity.  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Introduction  
Connectivity  
The 9M426-02 module has one interface to the INB-2 and two front panel HSIM  
interfaces.  
Management Information Base (MIB) Support  
For a complete list of supported MIBs, refer to the release notes provided in the  
9M426-02 package.  
LANVIEW LEDs  
The 9M426-02 uses LANVIEW – the Cabletron Systems built-in visual diagnostic  
and status monitoring system. With LANVIEW LEDs, you can quickly identify  
the device, port, and physical layer status at a glance.  
HSIM Modules  
The 9M426-02 module uses standard Cabletron HSIMs. These are not shipped  
with this unit and may be purchased separately.  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
9M426-02  
SMB  
INB  
CPU  
Figure 1-1. The 9M426-02 Module  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Related Manuals  
The manuals listed below should be used to supplement the procedures and  
technical data contained in this manual.  
SmartSwitch 9000 Installation Guide  
SmartSwitch 9000 9C300-1 Environmental Module Users Guide  
SmartSwitch 9000 9C214-1 AC Power Supply Users Guide  
INB Terminator Modules Installation Guide  
SmartSwitch 9000 Module Local Management Users Guide  
Getting Help  
For additional support related to this device or document, contact the Cabletron  
Systems Global Call Center:  
Phone  
(603) 332-9400  
Internet mail  
FTP  
ctron.com (134.141.197.25)  
anonymous  
Login  
Password  
your email address  
BBS  
(603) 335-3358  
Modem setting  
8N1: 8 data bits, No parity, 1 stop bit  
For additional information about Cabletron Systems or its products, visit the  
World Wide Web site: http://www.cabletron.com/  
For technical support, select Service and Support.  
To send comments or suggestions concerning this document, contact the  
Cabletron Systems Technical Writing Department via the following  
email address: [email protected]  
Make sure to include the document Part Number in the email message.  
Before calling the Cabletron Systems Global Call Center, have the following  
information ready:  
Your Cabletron Systems service contract number  
A description of the failure  
A description of any action(s) already taken to resolve the problem (e.g.,  
changing mode switches, rebooting the unit, etc.)  
The serial and revision numbers of all involved Cabletron Systems products in  
the network  
A description of your network environment (layout, cable type, etc.)  
Network load and frame size at the time of trouble (if known)  
The device history (i.e., have you returned the device before, is this a recurring  
problem, etc.)  
Any previous Return Material Authorization (RMA) numbers  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2  
Installing the SmartSwitch 9000  
Module  
This module uses HSIMs for the front panel connections. They are not shipped  
with the module and must be purchased separately. For installation information,  
refer to the manual supplied with the HSIM.  
Unpacking the Module  
1. Carefully remove the module from the shipping box. (Save the box and  
packing materials in the event the module must be reshipped.)  
2. Remove the module from the plastic bag. Observe all precautions to prevent  
damage from Electrostatic Discharge (ESD).  
3. Carefully examine the module, checking for damage. If any damage exists,  
DO NOT install the module. Contact Cabletron Systems Technical Support  
immediately.  
User Accessible Components  
Figure 2-1 shows the various components that are accessible to the user. These  
consist of an eight position DIP switch, replaceable PROMs and sockets for RAM.  
These will be used for future upgrades. Instructions for installing the components  
will be supplied with the upgrade kit.  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installing the SmartSwitch 9000 Module  
SMB-1  
PROM  
i960  
Processor  
Boot  
PROM  
DIP Switch  
Local DRAM  
Socket  
Flash SIMM  
Socket  
1 2 3 4 5 6 7 8  
Figure 2-1. User Accessible Components  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the SmartSwitch 9000 Module  
An eight position DIP switch is located on the module card as shown in  
Figure 2-1. The function of the switches are listed in Table 2-1.  
See the Cautions at the end of this table.  
Table 2-1. Function of DIP Switch  
Switch  
Function  
Description  
When toggled, this switch clears user-entered  
passwords stored in NVRAM, and restores the  
default passwords. Once reset you can use the  
defaults or enter new passwords.  
Clear  
Password  
8
1
The module uses NVRAM to store user  
entered parameters such as IP addresses,  
device name, etc. To reset these parameters to  
the factory defaults, toggle this switch. Once  
reset you can use the defaults or enter new  
parameters which are stored in NVRAM when  
the module is powered down, and remain  
there until the switch is toggled again.  
Clear  
NVRAM  
7
2
Toggling this switch after pulling the board  
out of the SmartSwitch 9000, clears download  
information from NVRAM and forces image  
files to be downloaded from the station  
connected to the EPIM on the Environmental  
Module configured to act as that modules’  
BOOTP server.  
Force BootP  
Download  
6
5
4
3
2
1
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
For Factory Use Only  
For Factory Use Only  
For Factory Use Only  
For Factory Use Only  
For Factory Use Only  
1. Caution: Do not toggle Switch 8 unless you intend to reset the user  
configured passwords to their factory default settings.  
!
CAUTION  
2. Caution: Do not toggle Switch 7 unless you intend to reset the user  
parameters to the factory default settings.  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the SmartSwitch 9000 Module  
Installing the Module into the SmartSwitch 9000  
Chassis  
To install the SmartSwitch 9000 module, follow the steps below:  
The INB Terminator Modules must be installed on the rear of the chassis before powering  
up this module. Refer to the INB Terminator Modules Installation Guide for  
NOTE  
information and installation procedure.  
1. Remove the blank panel covering the two slots in which the module is being  
installed. All other slots must be covered, if other modules are not being  
installed, to ensure proper airflow and cooling.  
2. Attach one end of the ESD wrist strap packaged with the SmartSwitch 9000  
chassis to your wrist. Plug the other end into the ESD Wrist Strap Grounding  
receptacle in the lower right corner of the SmartSwitch 9000 Chassis shown in  
3. Grasp the module and slide it into the slots. Make sure that the modules  
circuit card is between the card guides, as shown in Figure 2-2. Check both the  
upper and lower tracks the card. Take care that the module slides in straight  
and engages the backplane connectors properly.  
4. Lock down the top and bottom plastic tabs, as shown in Figure 2-2.  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the SmartSwitch 9000 Module  
L
L
L
I
I
Jack for ESD  
wrist strap  
Metal Back-Panel  
Circuit Card  
Card Guides  
Warning:  
Ensure that the circuit card is between the card guides.  
Lock down the top and bottom plastic tabs  
at the same time, applying even pressure.  
Figure 2-2. Installing the 9M426-02 Module  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the SmartSwitch 9000 Module  
The Reset Switch  
The Reset switch is located under the top plastic tab as shown in Figure 2-3.  
Use the reset switch to reset the modules processor, shutdown (power down) the  
module, and/ or restart the module.  
To reset the modules i960 processor, press the reset switch twice within three  
seconds.  
To shutdown the module, press and hold the reset switch for three or more  
seconds.  
To restart the module, press the reset switch momentarily.  
SNMP management may be used to disable this switch to enhance module  
security.  
Reset Switch  
SMB  
CPU  
Figure 2-3. The Reset Switch  
2-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 3  
Operation  
The 9M426-02 FDDI SmartSwitch Module is a three port switch module with two  
front panel HSIM interfaces and one INB-2 backplane interface. This module,  
with the proper HSIM, may be used for an FDDI, ATM, WAN and other  
high-speed connectivity for the SmartSwitch 9000 chassis.  
System Management Buses  
There are two management channels within the SmartSwitch 9000 system: the  
SMB-1 and the SMB-10. These buses provide out-of-band management and inter-  
module management communication.  
SMB-1 Bus  
The SMB-1 is a 1Mbs management bus located within the SmartSwitch 9000. This  
bus is utilized by all diagnostic controllers in the system including connectivity  
modules, power supply modules and the environmental module. The SMB-1  
transports inter-chassis information between system components, such as power  
and environmental information, as well as diagnostic messages. Periodic  
loop-back tests are performed by all modules which share this bus to ensure the  
validity of SMB-1. In the event a failure is detected on SMB-1, the SMB-10 may be  
used as an alternate communication channel.  
SMB-10 Bus  
The SMB-10 is a 10Mbs management bus located within the SmartSwitch 9000  
which is also used for inter-chassis communication of modules as well as serving  
as an out-of-band management channel into the SmartSwitch 9000. The SMB-10 is  
externalized from the chassis via an optional Ethernet Port Interface Module  
(EPIM) located on the front of the Environmental Module. Through an EPIM  
connection, full SNMP management of the SmartSwitch 9000 is available out-of-  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Operation  
band from user data. Modules which share the SMB-10 bus periodically send out  
loop-back packets to ensure the validity of SMB-10. In the event a fault is detected  
on the SMB-10, the SMB-1 can be used as an alternate communication channel by  
the modules.  
System Diagnostic Controller  
This diagnostic controller is composed of a Z-80 microprocessor and its  
supporting logic. The diagnostic controller is designed to control the power-up  
sequencing of modules, monitor the 9M426-02 input and output power  
parameters, keep watch over the main host processor, as well as monitor the  
temperature and control the SMB LANVIEW diagnostic LED. Although the  
diagnostic controller and the main host processor can operate independent of  
each other if needed, they exchange information about each others status and  
overall module condition. The information gathered by the diagnostic controller  
is available to the network manager via local/ remote management and the LCD  
located on the environment module. The 9M426-02 has been designed so that in  
the event of a diagnostic controller fault, the 9M426-02 will continue to function.  
DC/DC Converter  
The DC/ DC converter converts the 48 VDC on the system power bus to the  
necessary operating voltages for its host network services module. The diagnostic  
controller monitors and controls the operation of the DC/ DC converter.  
INB Interface  
Each module that attaches to the INB has an INB Network Interface Block (NIB).  
The INB NIB converts canonical frames to fixed length data blocks for  
transmission onto the INB. For data blocks received from the INB, the INB NIB  
reassembles the data blocks received from the INB back into canonical frames for  
transmission to the SmartSwitch ASIC then from the SmartSwitch ASIC to the  
front panel ports.  
SecureFast Switch  
The SmartSwitch ASIC is a hardware based switch design that is the key building  
block of the SmartSwitch 9000. All filtering/ forwarding decisions are made in  
hardware as opposed to software as in traditional switches. This custom  
hardware allows the SmartSwitch ASIC to process over 150K frames per second.  
The SmartSwitch ASIC is designed to support up to 64 ports that are shared  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Operation  
between the host processor, the INB backplane, and LAN/ WAN interfaces on the  
front panel of SmartSwitch 9000 modules. The SmartSwitch ASIC can operate in  
two modes: as a traditional switch, or as a SecureFast Switch (SFS). When  
operating in traditional switch mode, it makes filtering/ forwarding decisions  
based on Destination Address (DA), with standard IEEE 802.1d learning. When  
operating in SecureFast Switch mode, all filtering/ forwarding decisions are made  
based on a DA-SA pair and its receive port. These DA-SA pairs with the  
associated receive port are programmed into the switch using Cabletrons  
SecureFast Virtual Network Server (SecureFast VNS). This provides the network  
administrator with the ultimate network security without the performance  
degradation found when using routers or traditional switches with special  
filtering capabilities. The SmartSwitch 9000 enterprise switching system can  
support modules operating in traditional switch mode and SecureFast Switch  
mode simultaneously providing security when/ where needed and ease of  
configuration where security is not required.  
i960 Core  
The i960 core provides the SNMP protocol stacks, to support industry standard  
MIBs. Additionally, Cabletron enterprise extension MIBs are supported for each  
media type. Advanced management services, such as the Distributed LAN  
Monitor, telnet and network address to MAC address mapping, are also provided  
by the i960 core.  
The Host engine sends and receives packets via the CPU SmartSwitch ASIC  
Interface. This allows the traditional switch to perform spanning tree protocol and  
other traditional switching functions. The SMB Interfaces provide communication  
to the Host Engine for management functions and communication with other  
modules in the chassis.  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation  
3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
LANVIEW LEDs  
The front panel LANVIEW LEDs indicate the status of the module and may be  
used as an aid in troubleshooting. Shown in Figure 4-1 is the LANVIEW LEDs of  
the 9M426-02 module.  
System Status  
9M426-02  
FNB Transmit  
FNB Receive  
SMB  
INB  
CPU  
Figure 4-1. The LANVIEW LEDs  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
LANVIEW LEDs  
The functions of the two System Status LEDs, System Management Bus (SMB)  
and the CPU, are listed in Table 4-1.  
Table 4-1. System Status (SMB and CPU) LEDs  
LED Color  
State  
Description  
Fully operational.  
Green  
Yellow  
Functional  
Testing  
Power-up Testing  
Yellow (flashing) Crippled  
Not fully operational (i.e., one bad port).  
Blinks yellow and green while booting.  
Normal power-up reset.  
Yellow/ Green  
Red  
Booting  
Reset  
Red (Flashing)  
Off  
Failed  
Fatal error has occurred.  
Power off  
Module powered off.  
The functions of the INB receive LED are listed in Table 4-2.  
Table 4-2. INB Receive LED  
LED Color  
State  
Green (Flashing)  
Link, Port Disabled  
Green  
Link, Port Enabled, No activity  
Link, Port Enabled, Activity  
Fault  
Yellow (Flashing)  
Red  
Off  
No Link  
The functions of the INB transmit LED are listed in Table 4-3.  
Table 4-3. INB Transmit LED  
LED Color  
State  
Green (Flashing)  
Yellow (Flashing)  
Red (Flashing)  
Red  
Data Activity  
Port in Standby State  
Collision  
Fault  
Off  
No activity, Port Disabled  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 5  
Specifications  
Technical Specifications  
CPU  
Intel i960 RISC based microprocessor  
Memory  
4 Meg. Flash Memory (expandable to 8 Meg.)  
16 Meg. DRAM (expandable to 32 Meg.)  
Network Interface  
Cabletron HSIMs  
Safety  
It is the responsibility of the person who sells the system to which the module will be a  
part to ensure that the total system meets allowed limits of conducted and radiated  
emissions.  
!
CAUTION  
This equipment meets the safety requirements of:  
UL 1950  
CSA C22.2 No. 950  
EN 60950  
IEC 950  
EMI Requirements of FCC Part 15 Class A  
EN 55022 Class A  
VCCI Class I  
5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Specifications  
EMC requirements of:  
EN 50082-1  
IEC 801-2 ESD  
IEC 801-3 Radiated susceptibility  
IEC 801-4 EFT  
Service  
MTBF (MHBK-217E)  
MTTR  
>200,000 hrs.  
<0.5 hr.  
Physical  
Dimensions  
35.0 D x 44.0 H x 6.0 W centimeters  
(13.8 D x 17.4 H x 2.4 W inches)  
Weight  
Unit:  
Shipping:  
2.6 kg. (6lb)  
3.6 kg. (8lb)  
Environment  
Operating Temperature  
Storage Temperature  
Relative Humidity  
5 to 40° C  
-30 to 90° C  
5% to 95% non-condensing  
5-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         

Black Decker Chipper GS2400 User Manual
Black Decker Router BDCMTJSR User Manual
Bosch Power Tools Router 0601613639 User Manual
Boss Audio Systems Car Amplifier CH1200M User Manual
Braun Mixer MR 5500 M User Manual
Briggs Stratton Automobile Parts 110700 User Manual
Brinkmann Landscape Lighting 822 2500 2 User Manual
Campbell Hausfeld Pressure Washer IN470200AV User Manual
Canon Camera Accessories 4411B002 User Manual
Channel Plus Speaker H424 User Manual