INSTALLER / CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
Dutchwest
Natural Vent Gas
Heater
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROP-
ERTY DAMAGE, PERSONAL IN-
JURY OR LOSS OF LIFE.
Models: 2467, 2468
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency or the gas suppler.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from your neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
DO NOT STORE OR USE GASO-
LINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER
APPLIANCE.
Homeowner’s Installation
and Operating Manual
S
G
N
E
D
This appliance may be installed in an after
market permanently located manufac-
tured (mobile) home where not prohibited
by local codes.
CERTIFIED
C
E
D
R
E
I
T
I
F
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
30002008 7/04 Rev. 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Installation & Operating Instructions
The Dutchwest Natural Vent Room Heater, Model Nos. 2467
This appliance is approved for bedroom installations in the
and 2468, is a vented gas appliance listed to the ANSI standard U.S. and Canada.
Z21.88b-2001 and CSA-2.33b-2001 for Vented Room Heaters,
This appliance may be installed in an aftermarket* manufac-
and CSA 2.17-M91, Gas-Fired Appliances For Use at High Alti- tured (mobile) home, where not prohibited by state or local codes.
tudes.
The Dutchwest Natural Vent Room Heater, when installed,
The installation of the Dutchwest Natural Vent Room Heater must be electrically grounded in accordance with local codes or,
must conform with local codes, or in the absence of local codes, in the absence of local codes, with the National Electrical Code
with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest ANSI/NFPA 70, (latest edition), or of the current Canadian Elec-
edition and CSA B-149.1 Installation Code. (EXCEPTION: Do trical Code C22.1.
not derate this appliance for altitude. Maintain the manifold pres-
sure at 3.5 inches w.c. for Natural Gas and 10 inches w.c. for LP out of traffic and away from furniture and draperies.
gas at maximum input.) WARNING: This appliance is hot while in operation. Keep
Duetohightemperaturesthisapplianceshouldbelocated
This appliance is only for use with the type of gas indicated on children, clothing, and furniture away. Contact may cause
the rating plate. This appliance is not convertible for use with burns or ignition of combustible materials.
other gases unless a certified kit is used.
Children and adults should be alerted to the hazards of
Installation and replacement of gas piping, gas utilization high surface temperatures and should stay away to avoid
equipment or accessories, and repair and servicing of burnsorclothingignition.Youngchildrenshouldbecarefully
equipment shall be performed only by a qualified agency. supervisedwhentheyareinthesameroomastheappliance.
The term “qualified agency” means any individual, firm,
Clothing or other flammable materials should not be
corporation, or company that either in person or through a placed on or near the appliance.
representative is engaged in and is responsible for (a)
Any safety screen, glass or guard removed for servicing
installation or replacement of gas piping, or (b), the an appliance must be replaced prior to operating the
connection, installation, repair, or servicing of equipment, appliance.
whoisexperiencedinsuchwork,familiarwithallprecautions
The appliance area must be kept clear and free from
required, and has complied with all the requirements of the combustiblematerials,gasoline,andotherflammablevapors
authority having jurisdiction.
and liquids.
The Dutchwest Natural Vent Room Heater should be
The flow of combustion and ventilation air must not be
inspected before use and at least annually by a qualified obstructed. The installation must include adequate
service agency. It is imperative that control compartments, accessibility and clearance for servicing and proper
burners, andcirculatingairpassagewaysoftheappliancebe operation.
kept clean.
WARNING: DonotoperatetheRoomHeaterwiththeglass
The Dutchwest Natural Vent Room Heater and its individual panel removed, cracked or broken. Replacement of the
shut-off valve must be disconnected from the gas supply piping panel should be done by a licensed or qualified service
during any pressure testing of that system at test pressures in person.
excess of 1/2 psig (3.5 kPa).
Donotusethisapplianceifanyparthasbeenunderwater.
The Dutchwest Natural Vent Room Heater must be isolated Immediately call a qualified service technician to inspect the
from the gas supply piping system by closing its individual manual appliance and to replace any part of the control system and
shutoff valve during any pressure testing of the gas supply pip- any gas control which has been under water.
ing system at test pressures equal to or less than 1/2 psig.
Do not burn wood, trash or any other material for which
An accessible tap is located above the pilot/on-off knob for this appliance was not designed. This appliance is designed
checking the inlet pressure.
to burn either natural gas or propane only.
This appliance needs fresh air for safe operation and must be
This gas appliance must not be connected to a chimney
installed so there are provisions for adequate combustion and flue serving a separate solid-fuel burning appliance.
ventilation air. CAUTION: Label all wires prior to disconnection when
This appliance must be properly connected to a listed 4” servicing controls. Wiring errors can cause improper and
(100mm) Type B venting system or to an approved masonry or dangerous operation.
factory-built chimney system. In Canada, a complete reline of
Class A chimneys is required. This heater is equipped with a vent
safety shutoff system.
Verify proper operation after servicing.
This appliance must be properly connected to a venting
system. WARNING: Operation of this heater when not
connected to a properly installed and maintained venting
system or tampering with the vent safety shutoff system can
result in carbon monoxide (CO) poisoning and possible
death.
* Aftermarket: Completion of sale, nor for purpose of resale,
from the manufacturer.
Proposition 65 Warning: Fuels used in gas, woodburning or
oil fired appliances, and the products of combustion of such
fuels, contain chemicals known to the State of California to
cause cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6
30002008
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Dutchwest Natural Vent Gas Heater Dimensions
See Page 5 for Flue Collar
Centerline Dimensions.
6³⁄₄"
(172mm)
C
L
Valve Inlet
24¹⁄₂"
(622mm)
28³⁄₈"
(721mm)
Valve
Inlet
C
L
4³⁄₈"
(111mm)
12¹⁄₂"
(318mm)
23"
(584mm)
17"
(419mm)
Fig. 1 Dutchwest dimensions.
44
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Ceiling Clearances
Clearance Requirements
Minimum Clearances to Combustible
Materials
45"
(1140mm)
Measure side clearances as shown in Figures 2
through 5 from the outer edge of the cast iron stove
top. Measure rear clearances from the outermost
surface of the sheet metal rear skirt.
72"
(1829mm)
The Dutchwest heater is approved for installation into
an alcove constructed of combustible materials to the
dimensions and clearances shown in Figure 5.
The same clearances apply in a standard parallel
installation.
ST774
Fig. 4 Minimum ceiling clearance; minimum alcove height.
Parallel Installation: Minimum Clearance
and Flue Centerline
Alcove Minimum Dimensions
C
L
C
C
A
D
C
L
A
A
B
A: 4” (102mm)
B: 33” (838mm)
C: 5” (125mm)
B
ST775
Fig. 5 The Dutchwest Natural Vent Stove is approved for
installation into alcoves built of combustible materials.
Stove Clearances
Pipe Centerlines
A: 5” (125mm)
B: 4” (102mm)
C: 16” (406mm)
D: 9¹⁄₄” (235mm)
Hearth Requirements
ST128c
The Dutchwest Heater must be installed on rigid
flooring. When the heater is installed directly on any
combustible surface other than wood flooring, a metal
or wood panel extending the full width and depth of the
unit must be used as the hearth. There are no other
hearth requirements.
Fig. 2 Parallel installation requirements.
Corner Installation: Minimum
Clearance and Flue Centerline
B
WARNING:
Always maintain required
A
•
clearances (air spaces) to nearby
B
combustibles to prevent fire hazard. Do not
fill air spaces with insulation. All venting
components must maintain a 1" (25mm)
clearance to combustible materials. Maintain
a 6” (150mm) clearance when using single
wall pipe.
The gas appliance and vent system must be
vented directly to the outside of the building
and never be attached to a chimney serving a
separate solid fuel or gas-burning appliance.
Refer to the manufacturer's instructions
included with the venting system for
complete installation procedures.
A
•
•
Stove Clearance
Pipe Centerline
A: 4” (102mm)
B: 17” (432mm)
ST129c
Fig. 3 Corner installation requirements.
30002008
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Gas Specifications
Venting Requirements and Options
Max.
Input
BTU/h BTU/h
28,000 20,000
28,000 19,000
Min.
Input
The Dutchwest must be properly connected to a listed
4” (100mm) Type B venting system or to an approved
Class A masonry or factory-built chimney system. In
Canada, a complete relining of Class A chimney
systems is required.
Model
2467
Fuel
Nat
Gas Control
Millivolt
2468
Prop
Millivolt
The Dutchwest Natural Vent stove will accept decora-
tive 6” (150mm) stove pipe around the Type B venting
system, for aesthetic purposes.
Weight: Fully assembled 350 lbs.
Gas Inlet and Manifold Pressures
Complete Type B vent systems are available from a
number of manufacturers, and your dealer can usually
supply one. Pipe sections from different makers are not
interchangeable; do not mix pipe or vent sections from
different makers. Follow the vent system
Natural
LP (Propane)
Inlet Minimum
5.5” w.c.
11” w.c.
14” w.c.
10” w.c.
Inlet Maximum
Manifold Pressure
14” w.c.
3.5” w.c.
manufacturer’s instructions.
The vent system should conform to the specifications
of the National Fuel Gas Code, latest edition.
Dutchwest Natural Vent
Certified to:
ANSI Z21.86b-2001 / CSA Z2.33b-2001
Vented Gas Fireplace Heaters
If connecting to a Class A chimney system, use 4”
(100mm) single wall or 4” Type B vent connector.
Single wall vent connector requires a minimum 6”
(150mm) clearance to combustible surfaces.
Exterior chimneys may be subject to flow reversal or
condensation. To lessen these conditions, enclose
Type B vents in an insulated chase, or reline exterior
Class A chimneys.
The installation must conform with local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
(EXCEPTION: Do not derate this appliance for
altitude. Maintain the manifold pressure at 3.5” w.c.
for Natural Gas and 10” w.c. for Propane.)
An approved pass-through device is always required,
whether the vent system passes through a wall or a
ceiling. Use a pass-through device from the same
maker who supplies the venting system.
High Elevations
Venting terminals shall not be recessed into a wall or
siding.
Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
Vent Layout and Height Requirements
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the
current ANSI Z223.1/NFPA 54 and/or local codes
having jurisdiction.
Venting for a Dutchwest can rise vertically through the
home, or can pass through an exterior wall and rise
along the outside of the home. Some codes require
that a Type B vent system rising on the outside of the
home be enclosed in a chase. Check your local codes
for requirements.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).
The minimum vent system height for the Dutchwest
Natural Vent Stove is 8’ (2.43m), (Fig. 7) measured
from the top of the stove. To determine the minimum
height the vent system must extend through or past the
roof, refer to the 1993 edition of the National Fuel Gas
Code.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual
for correct installation and operational proce-
dures. For assistance or additional information
consult a qualified installer, service agency, or
the gas supplier.
66
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Passing Through a
Combustible Wall or Ceiling
Venting Requirements
36
34
An approved pass-through device is always required
when a vent passes through a combustible wall or
ceiling. Check with the maker of the vent system for
the correct listed devices that are available. A listed
pass-through device is required whether or not the
installation includes decorative pipe around the Type B
venting system. NOTE: It is essential to seal between
the ceiling support (sometimes called a ‘firestop
spacer’) and the decorative pipe, if installed, with a
high-temperature silicone sealant. (Fig. 6)
A
32
B
30
28
26
24
22
20
18
16
14
12
10
8
Complete the venting system installation according to
the manufacturer’s instructions.
Joists
Air Space as
Required by
Code
6
4
Ceiling
Support
2
1
2
4
6
8
10 12 14 16 18 20 22 24
High-
Horizontal Run (in feet)
Temperature
Silicone
Trim
Collar
Sealant
Venting Runs
High-
Decorative
6” Pipe
NOTE: When venting staight vertical, without an
elbow, a minimum of 8 ft. vertical is required
off the top of the stove.
Temperature
Silicone
Sealant
Listed 4”
(102mm)
B-Vent
= Acceptable venting configuration
= Unacceptable venting configuration
Air Space
ST361
Fig. 6 A ceiling pass-through, with decorative pipe around
the vent.
A: Vertical installations up to 36 feet (12m) in
height. Up to an 18 ft. horizontal vent run can be
installed within the vent system using a
maximum of two 90-degree elbows or four
45-degree elbows.
B: Vertical installations up to 36 feet (12m) in
height. Up to a 24 ft. horizontal vent run can be
installed within the vent system using a
maximum of two 45-degree elbows.
(Ratio = 2/3, Hor./Vert.)
FP567b
Fig. 7 Vent termination window.
30002008
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
4. Disassemble the inner shroud from the outer shroud
by removing the four screws, two on each side.
Install the Optional Fan
1. The fan kit includes a blower assembly and a
rheostat assembly, connected by a cable. The
blower assembly mounts to the bottom rear of the
stove, and the rheostat mounts to the left side of the
valve. The assembly includes a ‘snapstat’ which
automatically turns the fan ON (or OFF) above (or
below) approximately 109°F. The rheostat also
provides a range of fan speed settings from Off
(which overrides the snapstat function) to High.
Unpack and inspect the blower assembly. Confirm
that the fan spins freely.
5. Place the grommet provided in the manual bag
assembly on the inner shroud. Run the snapstat
extension assembly leads through the grommet
toward the firebox. (Fig. 10)
Left Air
Duct
Inner
Shroud
Grommet
2. Attach the fan assembly to the bracket provided in
the log box. Use #10 sheet metal screws provided
with fan kit. Do not remove finger guard screws.
(Fig. 8)
Snapstat
Wire
Rheostat Wire
Fan
Front View
ST720
Fan
Bracket
Fig. 10 Attach snapstat wire assembly to inside of inner
shroud with clamp screws.
6. Assemble the inner shroud to the outer shroud
using previously removed screws.
7. Position the fan assembly so the ducts slide
between the inner and outer shroud. The inner
shroud should engage with the two slots in the ends
of the bracket so the bracket and shroud are
interlocked. (Fig. 11) Secure the bracket with the
four sheet metal screws provided in the finish bag.
Finger Guard
ST669
Fig. 8 Attach the fan assembly to the fan bracket.
3. Connect snapstat leads. Disconnect the snapstat
module from the leads inside the snapstat bracket.
(Fig. 9) Bend open the snapstat bracket. Use
needle nose pliers to remove the black plastic
grommet from the bracket. Discard the bracket.
Connect the two wires to the two snapstat extension
leads provided with the parts bag (wires with the
sleeve).
8. Install the snapstat by loosening the front screw on
the inner side of the duct. (Fig. 12) Slide the
snapstat under the head of the screw and tighten.
Connect the leads to the snapstat. Make sure the
snapstat assembly is mounted straight front to back.
Outer
Shroud
Slot
Inner Shroud
Snapstat Bracket
Snapstat Module
Pinch
Grommet to
Remove
Slot
ST194
Fig. 11 Position the fan to engage the inner shroud with the
fan bracket slots and secure with sheet metal screws.
ST670
Fig. 9 Remove the snapstat and grommet from the bracket
88
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Venting System Assembly
Snapstat
Left Air Duct
The venting collar is on the sheet metal draft hood/heat
exchanger assembly, over the firebox. Use a B-vent
adapter, from the same maker as the rest of the B-vent
components, to join the first section of venting to the
draft hood.
The stove includes a spill switch. Operating this stove
when not connected to a properly installed and main-
tained venting system, or tampering with or disconnect-
ing the spill switch, can result in carbon monoxide (CO)
poisoning and possible death.
ST671
Fig. 12 Install the snapstat and connect the extension wire
terminals. View is with top removed, however, access is
available through the rear when installing fan before gas line
connection.
The stove includes a bracket for installing decorative 6”
(150mm) round stove pipe around the B-vent, for
appearance purposes only. The decorative pipe need
not be concentric with the vent pipe.
9. After sliding the firebox in place, the rheostat control
switch attaches to the left side of the valve bracket
at the front of the stove. (Fig. 13)
• Remove the plug from the rheostat bracket.
If the installation includes decorative stove pipe around
the venting system, make a cardboard template of the
decorative pipe by tracing its circumference. Put this
template in the flue recess in the stove top. Position
the template to fit well against the front of the recess.
(Fig. 16) Use this template to locate the bracket to hold
the decorative pipe. Depending on spacing, the bracket
may fit inside the decorative pipe without interfering
with the vent system. Fasten the bracket to the draft
hood/heat exchanger assembly with a sheet metal
screw.
• Insert the switch box shaft through the hole in
the back of the right side of the valve bracket,
aligning the locator pin with the smaller hole in
that bracket.
• Attach the control knob to the rheostat shaft.
• Use the wire tie to secure the fan and rheostat
wire harnesses together.
10.Plug the power cord into a standard grounded 110
volt household outlet. If the fan control knob is not
turned to the OFF position, the fan will turn on when
the temperature at the snapstat reaches
approximately 109°F.
Sheet Metal Screw
Bracket
Template
Rheostat
ST777
Retaining Nut
Fig. 16 Use a template to locate the bracket for decorative
Control Knob
ST758
pipe to surround the B-vent pipe.
Insert the B-vent adapter into the flue collar and drill
1/8” (3mm) pilot holes through both the stove’s collar
and the adapter. Attach the adapter to the flue collar
with sheet metal screws. (Fig. 17)
Fig. 13 Attach rheostat to left side of valve.
MOTOR
BLK
SNAPSTAT
WHT
BLK
ON/OFF
RHEOSTAT
POWER
ST196
ST778
Fig. 14 #2767 / FK26 fan wiring diagram.
Fig. 17 Attach the B-vent adapter to the flue.
30002008
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Attach the first section of venting to the B-vent adapter.
Depending on the length of the individual venting
sections and the lengths of the decorative pipe, you
may need to slip the decorative pipe over the venting
sections before attaching upper sections to lower ones.
The sections of decorative pipe should be oriented with
their seams (if any) toward the wall; sections usually
do not need to be fastened at each joint, other than slip
sections. The decorative pipe need not be fastened to
the locating bracket on the stove. If the layout includes
a slip section, this should be the last section of pipe
visible in the room at the ceiling. Refer to Page 7,
Figure 6 for details on joining the decorative pipe at the
Connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the
firebox, to confirm that you have the appropriate firebox
for the type of fuel to be used. The Dutchwest may be
converted from one gas to another using the appropri-
ate Fuel Conversion Kit listed on Page 23.
CAUTION
This appliance should only be
connected by a qualified gas techni-
cian. Test to confirm manifold
pressures as specified below.
ceiling.
The Dutchwest Heater and its individual shutoff
valve must be disconnected from the gas supply
piping during any pressure testing of that system
at test pressures in excess of 1/2 psig (3.5 kPa).
B-vent Pipe
Decorative
Pipe 7FSSK
Bracket
The Dutchwest Heater must be isolated from the
gas supply piping system by closing its indi-
vidual manual shutoff valve during any pressure
testing of the gas supply piping system at test
pressure equal to or less than 1/2 psig.
There must be a gas shutoff between the stove
and the supply.
ST374
Fig. 18 Install decorative pipe over the B-vent pipe.
In order to connect Natural Gas, use a fitting with
3/8” NPT nipple on the valve side and 1/2” natural
gas supply line with an input of 28,000 BTUs at a
manifold pressure of 3.5” and a minimum inlet
supply pressure of 5.5” w.c.
In order to connect Propane, use a fitting with
3/8” NPT nipple on the valve side and 1/2” pro-
pane gas supply line with an input of 26,000
BTUs at a manifold pressure of 10.0” and a
minimum inlet supply pressure of 11.0” w.c.
In the U.S.; Gas connection should be made in accor-
dance with current National Fuel Gas Code, ANSI
Z223.1/NFPA 54. Since some municipalities have
additional local codes, be sure to consult you local
authority.
In Canada; consult the local authority and CSA-B149.1
installation code.
Connect the gas supply and test for leaks. Use a 50/50
solution of liquid soap and water to test for leaks at gas
fittings and joints. Apply water/soap solution with brush
only - do not over apply. NEVER test with an open
flame. Light the pilot according to the directions on
Page 14, before going to the next step.
1010
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Burner Information
The appliance must only use the gas specified on the
rating plate, unless converted using a CFM Specialty
Home Products Fuel Conversion Kit. Refer to Page 23
for the correct Fuel Conversion Kit for your model.
Conversion instructions are provided with each kit and
beginning on Page 16 in this manual.
ST228
THIS APPLIANCE SHOULD BE CON-
NECTED TO THE GAS SUPPLY ONLY BY A
QUALIFIED GAS SERVICE TECHNICIAN.
FOLLOW ALL LOCAL CODES.
Fig. 20 Attach switch wires to valve.
Thermostat Connection (optional)
THERE MUST BE A GAS SHUT-OFF BE-
TWEEN THE STOVE AND THE SUPPLY.
Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge
thermostat wire to use for the length of lead required in
your installation.
In order to connect Natural Gas, use a fitting with 3/8”
NPT nipple on the valve side and 1/2” natural gas
supply line with an input of 28,000 BTUs at a manifold
pressure of 3.5” and a minimum inlet supply pressure of
5.5” w.c.
Thermostat
Wire / Gauge
Maximum Run
40 feet
18
20
22
25 feet
16 feet
In order to connect Propane, use a fitting with 3/8”
NPT nipple on the valve side and 1/2” propane gas
supply line with an input of 26,000 BTUs at a manifold
pressure of 10.0” and a minimum inlet supply pressure
of 11.0” w.c.
1. Install the wall thermostat in the desired location and
run the wires to the stove location. Terminate these
leads with 1/4” female connectors.
2. Connect the thermostat wires to the valve. (Fig. 20)
Install ON/OFF Switch
Install the Log Set
The switch assembly parts are found in the parts bag.
1. Attach switch assembly to left rear side of stove
shroud (when facing shroud) using two screws and
existing holes in shroud. (Fig. 19)
2. Run wires down back of stove, under bottom of rear
shroud to valve.
1. Remove the logs from their packaging, and inspect
each piece for damage. DO NOT INSTALL DAM-
AGED LOGS.
2. Install the rear log centering it side to side on the
sheet metal shelf at the back of the firebox. (Fig. 21)
The log will touch both sides and the back wall of
the firebox.
3. Attach wires to valve terminals. (Fig. 20)
3. Install the right log by engaging hole on bottom with
pin on the rear log. (Fig. 21) Then set right bottom
side on the burner so the edge of the log touches
the right side of the firebox. The right log does not
use the locator pins on the burner to stay in place.
Switch
Assembly
Existing
Holes
4. Install the left log by engaging hole on bottom with
pin on rear log. (Fig. 21) Then set left bottom side
on the burner so the edge of the log touches the left
side of the firebox.
Screws
ST315
5. Loosely sprinkle the lava rocks directly on top of the
burner in front of and between the decorative grate
and the right and left logs. Use the lava rock to
cover brackets on the burner. (Fig. 22)
Fig. 19 Attach switch assembly to rear shroud.
30002008
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Install the Stove Front
Left Log
Insert the handle stub into the hole in the front casting.
Fasten in place with the 3/8” locking nut provided. (Fig.
23)
Right
Log
The front attaches to the stove by four steel tabs that
engage with corresponding cast ribs onto the sides and
bottom of the stove body. Position the front about 3”
down from stove top and lift the plate to engage the
upper tabs behind the adjacent ribs on the sides. (Fig.
24) Then lower the front into position, so the lower tabs
engage with the corresponding ribs at the bottom.
When properly installed, the bottom of the stove front
cannot be pulled away from the sides without also lifting
it.
Rear Log
Decorative Grate
LG141
3/8”
Locking
Nut
Fig. 21 Install the back, left and right logs.
Handle Stub
ST773
Fig. 23 Insert handle stub into hole in front. Secure with 3/8”
locking nut.
Engage steel
tabs behind
the cast iron
bosses
Lava Rock
DUU
TT
CC
HHWE
LG142
E
Es
t.
19
74
SS
TT
Fig. 21 Completed log installation.
Bottom tabs engage
notch in the leg
ST780
Fig. 24 Install the front plate.
1212
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Operation
Your First Fire
Read these instructions carefully and familiarize
yourself with the burner controls. Locate the pilot
assembly, Figure 25. Follow the lighting instructions on
Page 14 exactly.
During the first fire, it is not unusual to smell some
odor associated with new logs, paint and metal being
heated. Odors should dissipate within an hour or so,
however, you can open a window to provide fresh air
CO105c
to alleviate the condition.
Fig. 26 Correct pilot flame pattern.
Pilot and Burner Inspection
Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in
Figures 26 and 27. If flame patterns are incorrect, turn
the heater off. Contact your dealer or a qualified gas
technician for assistance. Do not operate the heater
until the pilot flame is correct.
Follow regular maintenance procedures as described
on Page 19.
Red Glow
LG143
Fig. 27 Correct burner flame pattern.
Pilot
Assembly
ST769
Fig. 25 Pilot Assembly location.
30002008
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Lighting and Operating Instructions
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manu-
ally. When lighting the pilot follow these instruc-
tions exactly.
instructions.
If you cannot reach your gas supplier, call the
Fire Department
•
B. BEFORE LIGHTING smell all around the heater
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call a
qualified service technician. Applying force or any
attempted repair may result in a fire or explosion.
WHAT TO DO IF YOU SMELL GAS
•
•
•
•
Do not try to light any fireplace
Do not touch any electric switch
Do not use any phone in your building
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the heater and to replace any part of
the control system and any gas control which has
been under water.
Lighting Instructions
1. STOP! Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go on to
Step 4. For RN/RP appliances turn the On/Off
switch to “OFF” position or set thermostat to
lowest level.
10. Push the control knob all the way in and hold.
Immediately light the pilot by repeatedly
depressing the piezo spark ignitor until a flame
appears. Continue to hold the control knob in for
about one (1) minute after the pilot is lit. Release
knob and it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 5 through 8.
4. Open control access panel.
5. Push in gas control knob slightly and turn
clockwise
to "OFF".
3/8" - 1/2"
OFF
PILOT
2
O
Honeywell
Euro SIT
SIT NOVA
•
If knob does not pop up when released, stop
and immediately call your service technician or
gas supplier.
6. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you
smell gas, STOP! Follow "B" in the safety
information above. If you do not smell gas, go
to the next step.
7. Remove glass door before lighting pilot. (See
Glass Frame Removal section).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to "PILOT".
•
If after several tries, the pilot will not stay lit,
turn the gas control knob to "OFF" and call your
service technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the On/Off switch to
“ON” position or set thermostat to desired setting.
14. Turn on all electrical power to the fireplace.
To Turn Off Gas To Heater
1. Turn the On/Off switch to Off position or set the
thermostat to lowest setting.
3. Open control access panel.
4. Push in gas control knob slightly and turn
2. Turn off all electric power to the fireplace if
service is to be performed.
clockwise
5. Close control access panel.
to "OFF". Do not force.
1414
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Troubleshooting / Honeywell #8420 Gas Control System
NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position.
WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK.
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
A. Defective or misaligned
electrode at the pilot
Using a match, light [ilot. If pilot lights, turn off pilot and
push the ignitor button again. If pilot will not light, check
gap at electrode and pilot - it should be 1/8” to have a
strong spark.
1. Spark ignitor will
not light
B. Defective ignitor (push
button)
Push piezo ignitor button. Check for spark at electrode
and pilot. If there is no spark at the pilot, and electrode
wire is properly connected, replace ignitor.
A. Defective pilot generator
(thermocouple)
Check pilot flame. It must impinge on the thermocouple
or thermopile. NOTE: This pilot burner assembly uses
both a thermocouple adn a thermopile. The thermo-
couple operates the pilot flame. Tighten the thermo-
couple. The thermopile operates the main valve. (ON
and OFF) Clean and/or adjust pilot for maximum flame
impingement on thermocouple and thermopile.
Turn valve knob to “Pilot”. Maintain flow to pilot; millivolt
mete should read greater than 10mV. If the reading is
okay and the pilot does not stay on, replace the gas
valve. NOTE: An interrupter block (not supplied) must
be used to conduct this test.
2. Pilot will not stay lit
after carefully
following the
lighting instructions
B. Defective automatic valve
operator
C.Defective safety switch
Check the continuity accross the safety limit switch with
the unit cold. If there is no continuity, the safety switch
needs to be replaced.
A. Remote switch or wires
defective
Check rocker switch and wires for proper connection
Use jumper wires across terminals at rocker switch. If
burner lights, replace rocker switch. If okay, use jumper
wires across rocker switch wires at the valve. If burner
lights, wires are faulty or connections are bad.
1. Be sure wire connecitons from thermopile at gas
valve terminals are tight and thermopile is fully inserted
into pilot bracket.
3. Pilot lights, no gas
to burner, valve
knob ON, remote
switch (rocker
switch) ON
B. Thermopile may not gen-
ate sufficient voltage
2. One of the rocker switch wires may be grounded
Remove rocker switch wire form valve termianls. If
burner now stays lit, trace rocker switch wiring from
ground. It may be grounded to the appliance of the
gas supply line.
3. Check the thermopile with a millivolt meter. Take
reading at thermopile (“TP” and “TP/TH”) terminals of
gas valve. Should read 325 millivolts minimum while
holding valve knob depressed in PILOT position and
with rocker switch OFF. Replace faulty thermopile if
reading is below specified minimum.
C. Plugged burner orifice
D. Defective automatic valve
operator
Check burner orifices for debris, and remove.
Turn knob to ON, place rocker switch to ON. Millivolt
meter should read greater than 10mV. If the reading is
okay and the burner does not light, replace the valve.
Clean and/or adjust pilot flame for maximum flame
impingement on thermocouple and thermopile.
A. Pilot flame may be too low
or high, (blowing or lifting).
causing the pilot to drop out
B. Possible blockage of the
vent terminal
4. Frequent pilot
outage
Check the vent termianl for blockage.
30002008
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
5. Remove the rear log bracket by loosening the screw
and sliding the bracket up. CAUTION: Do not
remove the screw completely. It would be very
difficult to replace it. (Fig. 29)
Fuel Conversion Instructions
WARNING! This conversion kit shall be installed
by a qualified service agency in accordance with
the manufacturer’s instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in these instruc-
tions is not followed exactly, a fire, explosion or
production of carbon monoxide may result
causing property damage, personal injury or loss
of life. The qualified service agency is respon-
sible for the proper installation of this kit. The
installation is not proper and complete until the
operation of the converted appliance is checked
as specified in the manufacturer’s instructions
supplied with the kit.
Loosen Screw
Remove Screws
Rear Log Bracket
Pilot
Left & Right Log
Bracket Assembly
CAUTION: The gas supply shall be shut off prior
to disconnecting the electrical power, before
ST350
Fig. 29 Remove rear log bracket and left and right log
bracket assembly.
6. Remove the right and left log bracket assembly by
unfastening the two screws which hold the burner in
place. (Fig. 29)
OFF
7. Hold the burner at the right hand side and lift to clear
the right burner leg. Then pull to the right to clear the
injectors on the left hand side.
T
O
L
I
P
L
I
O
H
8. Remove injector orifices from left burner leg using
1/2” wrench. (Fig. 35)
Main
Gas Line
Gas Supply Inlet
9. Install conversion orifices. (Refer to Table 2)
ST770
10. Remove cap from HI/LO knob. This can be accom-
plished by lifting the plastic cap off the screw. (Fig.
30)
Fig. 28 Attach the gas line to the left side of the valve.
Conversion Precautions
11. Remove the screw from center of HI/LO knob with
small screwdriver turning counterclockwise. (Fig. 30)
Conversion must be completed only by qualified
personnel. Before proceeding, turn control knob on
valve to “OFF” and turn gas supply OFF. Turn OFF any
electricity that may be going to the appliance. CAU-
TION: Allow stove to cool completely before beginning
conversion.
12.Insert blue painted screw when converting to natural
gas and red painted screw when converting to LP.
13. Tighten screw (do not over tighten), replace cap.
Cap
Lift Open
Conversion Procedure
1. Remove stove front. Lift stove front up and then
swing bottom out and away to disengage from the
stove body. (Page 19, Fig. 36)
2. Swing open the swiveling latches at the top left and
right corners of the glass frame. (Page 20, Fig. 37)
Hi-Lo
Knob
Center Screw
CO100
3. Pull the top edge of the glass and frame assembly
away from the firebox face. Place the assembly out
of the way on a flat, padded surface such as a
counter protected by a towel.
Fig. 30 Remove center screw from Hi-Lo knob.
14. Locate pilot. (Fig. 29)
15. Replace pilot orifice.
• Remove pilot hood by lifting up. (Fig. 31) NOTE: It
is not necessary to remove the pilot tube for conver-
sion.
4. Remove the logset from the firebox.
1616
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
• Remove pilot orifice with allen wrench. (Fig. 32)
• Install the conversion orifice.
1/8"
Air Shutter
(LP Position)
• Reinstall pilot hood. Be sure to align hood with
index tab.
3/8"
Pilot Hood
Configuration for
Stove with Serial #’s
up to #5483
Air Shutter
(LP Position)
Pilot
Bracket
Configuration for Stoves with
Serial #’s Starting at #5484
ST726
CO105a
Fig. 34 LP air shutter settings.
Fig. 31 Remove pilot hood.
Index Tab
Left Burner Leg
Allen Wrench
Injector Orifices
90¡
Snap Ring
ST353a
CO106a
Fig. 35 Remove and replace injector orifices.
Fig. 32 Remove pilot orifice.
NOTE: Be sure burner leg remains at a 90° angle to
firebox base after conversion.
16. Adjust air shutter on the burner. The air shutter is
located on the bottom of the burner on the left. (Fig.
46) Loosen the two nuts holding the shutter in place.
On natural gas units, the shutter is shipped fully
closed. To convert to LP, reset the shutter as speci-
fied in Table 2. (Fig. 34) On propane unit the shutter
is set at 1/8” or 3/8” opening depending on rating
plate serial number. To convert to natural gas, the
shutter should set to fully closed. Refasten the two
nuts.
17. Replace burner. Slide the burner in at an angle with
left side lower than the right side. Slide the left side
onto the injectors, making sure the burner leg
remains at a 90° angle to the base. Lower the right
hand side down in to place. Make sure the burner is
as far left as possible and the injector shoulders are
inside the burner.
NOTE: It is very critical to keep the left burner leg,
which holds the injectors, at a 90° angel to the base.
(Fig. 35) This keeps the orifices aligned with the
tubes inside burner. Failure to do so could affect the
flame appearance and performance of the unit.
Front Injector Air Inlet
Air Shutter
18. Place conversion label on valve.
19. Reinstall the right and left log bracket assembly.
20. Replace logs.
Burner
Rear
21. Replace glass and stove front.
22. Check manifold pressure.
Conversion is complete.
Injector Air
Inlet -
Covered
Configuration for
Stove with Serial
#’s up to #5250
Air Shutter
Configuration for Stoves with
Serial #’s Starting at 5251
ST718
Fig. 33 Natural gas air shutter setting.
30002008
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Table 2. Injector Orifice Size Matrix
Conversion to Natural Gas
Part # Rear
Input (BTU/h)
Air Shutter
Setting
Kit #
Front
Part #
Minimum Maximum
000-5021 #54 / .055” 20000130 #44 / .086” 30000334
19,000
Input (BTU/h)
Minimum Maximum
21,500 28,000
28,000
Fully Closed
Conversion to LP
Air Shutter
Setting
Kit #
Front
Part #
Rear
Part #
000-5022 #69 / .029” 30000513 #54 / .055” 20000130
3/8” Open
1818
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Maintenance
Your Dutchwest Gas Heater will provide years of
CAUTION
service with minimal upkeep. The following procedures
will help ensure that your stove continues to function
properly.
TURN THE PILOT OFF BEFORE PAINTING.
ALLOW THE HEATER TO COOL COMPLETELY
BEFORE PAINTING.
Annual System Inspection
Have the entire heater and venting system inspected
annually by a qualified gas technician. Replace any
worn or broken parts.
Cleaning the Glass
WARNING: Let the glass cool completely before
attempting to clean.
Logset and Burner /
It will be necessary to clean the glass periodically.
During start-up, condensation, which is normal, forms
on the inside of the glass and causes lint, dust and
other airborne particles to cling to the glass surface.
Also, initial paint curing may deposit a slight film on the
glass. It is therefore recommended that the glass be
cleaned two or three times with a non-ammonia house-
hold cleaner and warm water (we recommend gas
fireplace glass cleaner). After that the glass should be
cleaned two or three times during each heating season
depending on the circumstances present.
Cleaning and Inspection
Cleanliness is critical to the proper function of the
heater. The logset and burner must all be kept free of
dust and unobstructed by debris. Inspect these areas
before each use and clean as necessary.
1. Turn the burner OFF and let the heater cool com-
pletely before cleaning.
2. Lift the Stove Front up and then swing the bottom
out to disengage it from the heater shell. (Fig. 36)
3. Carefully remove the glass and frame assembly and
place it out of the way on a flat, padded surface
such as a counter protected by a towel.
Clean glass after first two weeks of
operation.
4. Carefully inspect the Logs for damage. Contact your
local dealer if any damage is evident. DO NOT
Glass Replacement
OPERATE THE HEATER WITH DAMAGED LOGS.
Replace glass only with CFM Specialty Home Products
approved parts. Refer to Page 22 for Replacement
Parts. Refer to Figure 37 and previous instructions for
removal of the damaged glass frame.
5. Use a soft bristled brush to sweep dust or debris
from the Logs, Pilot and Burner. Use care as the
logs are fragile and susceptible to damage.
6. Replace the glass panel and frame assembly.
7. Replace the Stove Front.
Care of Cast Iron
An occasional dusting with a dry rag will help keep the
painted surfaces looking new. Use high-temperature
stove paints, available through your local dealer, to
touch-up areas as needed. Clean areas to be painted
with a wire brush and be sure to cover the logs, burner
and valve assembly, glass and frame assembly. Apply
the paint sparingly; two light coats of paint will give
better results than a single heavy coat.
DUU
TT
CC
HH
W
Es
EE
SS
TT
t.
1
97
4
Clean porcelain enamel surfaces with a soft, damp
cloth. Do not use abrasive cleaning agents. If neces-
sary, use only a cleaning agent formulated especially
for use on porcelain enamel surfaces.
ST771a
Fig. 36 Remove the Stove Front.
30002008
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Inspect the Vent System Annually
Have the vent system inspected annually by a quali-
fied technician. Shut off the main gas supply before
inspecting the system. Both the inner exhaust pipe and
the outer combustion supply pipe must be checked to
confirm that they are unblocked and in good condition.
Check the Gas Flame Regularly
To ensure that the stove is operating properly, check
the flames periodically to confirm they match Figure 39.
The flames will be blue during the first 15-20 minutes of
operation, and will gradually turn to yellow.
ST582
Fig. 37 Release the latches to release the glass frame.
Gasket Replacement
Do not use your stove if the flame pattern differs from
that shown here. Contact your Dutchwest dealer or a
qualified technician for help.
The Dutchwest Gas Heater uses a ‘tadpole’ type gasket
to seal between the glass panel and the frame. In time,
this gasket can become brittle and compressed and
should be replaced. New gasket is available from your
dealer.
Shut off the gas supply and allow the stove to cool.
Wear safety goggles and a dust mask.
1. Remove the Front, Glass Frame and Glass Panel.
(Figs. 36, 37) Remove the old gasket. Use a razor
blade, with rounded corners, to separate the glass
and gasket from the frame, and to clean the glass of
any remaining cement or bits of gasket.
2. Determine the correct length of gasket by laying it
out around the edge of the glass. Allow an extra 1 -
2” (25-50mm). Mark the spot to be cut. Use a utility
knife.
Red Glow
LG143
3. Starting on a long edge, remove about 6” of the
protective paper strip and apply the flat adhesive
face of the gasket around the outside-facing edge of
the panel. Continue around the panel, applying
about 6” at a time and being careful to not stretch
the material. Do not overlap the gasket ends. (Fig.
38)
Fig. 39 Correct flame pattern.
Stove Disassembly
If there is ever a need to remove the firebox assembly
from the stove shell, support the firebox with solid
stands about 6” (150mm) tall under the left and right
outer edges of the firebox base. Do not set the firebox
assembly directly on the floor; this can damage the
control valve and/or the gas lines from the valve to the
firebox.
4. Apply a thin bead of high temperature silicone
rubber sealant along the inside corner of the glass
frame, all around the perimeter. Place the flat
gasketed side of the glass panel back into the steel
frame. Pinch the rounded inside-facing gasket
material to bulk it up.
Before removing the firebox from the shell, disconnect
the on/off switch wires from the valve. If the assembly
includes the optional fan, disconnect the fan rheostat. If
the installation includes a wall thermostat, disconnect
the thermostat leads from valve.
5. Replace the glass frame and front panel as previ-
ously described.
Disconnection and reconnection to the gas line should
only be done by a qualified gas service technician.
Upon reinstallation, the vent system must be sealed to
the firebox as shown in the installation section, Page 9.
Also be sure the logs are placed in the firebox correctly,
as shown on Page 11, Figures 21, 22.
ST179
Fig. 38 Wrap the gasket material around the outside edge of
the glass.
2020
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Wiring Diagrams
FAN
ON
OFF
POWER
CORD
On/Off Switch
Wiring
WHT
BLK
BLK
TP/TH
TP
TH
Chassis
Ground
GRN
Black
ST124b
BLK
BLK
Thermostat
(Optional)
Optional Thermostat
Wiring
FAN JUNCTION BOX
Strain Relief
TP/TH
ON / OFF
Rheostat
TP
TH
Black
Snapstat
ST124c
WHT
BLK
Fig. 40 On/off switch and optional thermostat circuit.
BLK
GRN
NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-
PLIED WITH THE APPLIANCE, MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE SF-
2, 200°C WIRE OR ITS EQUIVALENT.
RHEOSTAT / SNAPSTAT
BOX
Chassis Ground
ST153
Schematic Diagram
MOTOR
Safety Limit
Switch
BLK
SNAPSTAT
WHT
BLK
ON/OFF
RHEOSTAT
Valve
ST236
Fig. 42 Fan circuit.
ST665
Fig. 41 Safety Limit Switch wiring.
30002008
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
4
9
2
8
1
5
1a
3
1c
1b
11
7
6
14a,b
10
13
12
OFF
17
PILOT
L
I
O
H
15a,b
18
16
19
22a,b,c,d
26
24
27
25
21
30a,b
29
28
20
23a,b
35
34
32
31
33
39
37
38
2008
CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products
at any time, without notice.
Dutchwest Natural Vent Gas Heater
Models 2467, 2468
Ref. Description
1. SDV30 Log Set Assembly
1a. Rear Log
Part Number
20003458
20003459
20003460
20003461
57897
1b. Right Log
1c. Left Log
2. Small Lava Rock Package
3. Top, NV DW Gas
4. Grille, NV DW Gas
5. Front, DW Gas
30002005
30002044
30001928
2222
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Dutchwest Natural Vent Gas Heater (continued)
Models 2467, 2468
Ref. Description
Part Number
30001929
30001930
30001927
30001926
1203702
6. Door, DW Gas
7. Leg, DW Gas
8. End, Rt - DW Gas
9. End, Lt - DW Gas
10. Gasket, Glass Med. Knit - RDV40
11. Glass, DV25
1601691
12. Glass Frame Assembly SDV30
13. Manifold Tube Assembly - Double Bead
14a. Valve RN Honeywell VS8420E 2038
14b. Valve RP Honeywell VS9420E 2020
15a. Pilot Assembly 3Way N/DV Rn 0.199.706
15b. Pilot Assemlby 3Way RP 0.199.703
16. Thermocouple 24”
30000127
20003739
10001782
10001759
10002264
10002265
53373
7531137
17. Electrode Ignitor w/ cable SIT 24
18. Pilot Top Convertible
19. Thermopile
10001297
10002266
51827
7533113
20. Tubing Pilot w/Fitting SIT
21. Nut Electrode SIT #0.974.144
22a. Orifice Hood #69 - 0.0292” (Front LP)
22b. Orifice Hood #54 (Front Natural)
23a. Orifice Pilot #62 NG Top Convertible
23b. Orifice Pilot #35 - LP Top Convertible
24. Burner Housing Assembly
25. Nut, Hex Jam 3/8 - 16 Top LK-Z
26. Front Pawl Assembly, Ash Door - ENC
27. Front Steel Handle/Shaft - NI/VER
28. Handle Package, Ceramic w/Screw
29. Grate Burner JDV
10001296
57886
30000513
20000130
10002268
10002269
20005264
1203290
5004025
5004237
0004342
20002167
51866
30a. Sensor Spill Switch, Bedroom
30b. Spill Switch
20005039
30000874
10002582
20005700
20005259
20005258
20002566
30000069
20005227
31. Switch Rocker
32. Wire w/Straight Term 2 End 50”
33. Spill Switch Wire Assembly
34. Bracket - Right Log
35. Bracket - Left Log
37. Gasket Base Pan Inner
38. Interrupter block
39. Draft Hood/Flue Collector Assembly
Fuel Conversion Kits
Conversion Kit, NG to LP - 2467
Conversion Kit, LP to NG - 2468
Kit #000-5022
Kit #000-5021
30002008
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
Optional Accessories Available
Fan Kits
Decorative Rings
FK26 Fan
4” brass or black rings are available to add a
decorative touch to the exposed stove pipe.
The FK26 fan kit helps distribute heated air from within
the firebox out into the room.. The fan is controlled by
a snapstat that turns power on and off as the firebox
temperature rises above and falls below a preset
temperature. A rheostat provides for variable fan
speeds.
Model
Description
4FSDRB/4
4” Black Rings (4)
4FSDRP/4 4” Polished Brass Rings (4)
Outside Air Adapter
Specifications
An outside air adapter, #5076, may be added to the
stove to bring fresh air for combustion directly from
outside the building into the stove.
115 Volt / 60Hz / .75 amps
Maintenance
The fan itself does not require regular maintenance,
however, periodic cleaning of the fan and the
surrounding area is required.
Installation
Refer to Page 8 for installation instructions.
Remote Controls
The remote control allows you to turn the heater on or
off from anywhere in the room. Refer to Page 21 for
wiring diagrams.
Model
Functions Controlled
MRC1
MRC2
MRC3
ON/OFF
ON/OFF and Temperature
ON/OFF and Temperature control
with a digital display and a
programmable 24 hour clock
Wall mounted thermostat control
IMT
2424
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
Dutchwest Natural Vent Gas Heater
30002008
25
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED LIFETIME WARRANTY
PRODUCT COVERED BY THIS WARRANTY
All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner.
BASIC WARRANTY
•
Any part and/or component replaced under the provisions of this
warranty is covered for six months or the remainder of the original
warranty, whichever is longest.
CFM Specialty Home Products Company (hereinafter referred to
collectively as the Company) warrants that your new Dutchwest Gas
Fireplace/Stove is free from manufacturing and material defects for
aperiodofoneyearfromthedateofpurchase, subjecttothefollowing
conditions and limitations.
•
This warranty is limited to the repair of or replacement of part(s) found
to be defective in material or workmanship, provided that such part(s)
have been subjected to normal conditions of use and service, after
said defect is confirmed by the Company’s inspection.
EXTENDED LIFETIME WARRANTY
•
•
Thecompanymay, at itsdiscretion, fullydischargeallobligationswith
respect to this warranty by refunding the wholesale price of the
defective part(s)
The heat exchanger, where applicable, and combustion chamber of
every Dutchwest gas product is warranted for life against through wall
perforation. All appliances equipped with an Insta-Flame Ceramic
Burner have limited lifetime coverage on the ceramic burner plaque.
Warrantees are made to the original owner subject to proof of
purchase and the conditions and limitations listed on this Warranty
Document
Any installation, labor, construction, transportation, or other related
costs/expensesarisingfromdefectivepart(s), repair, replacement, or
otherwise of same, will not be covered by this warranty, nor shall the
Company assume responsibility for same. Further, the Company will
not be responsible for any incidental, indirect, or consequential
damages except as provided by law.
COMPONENT WARRANTY
CAST IRON: All external and internal cast iron parts are warranted for a
period of three years.
•
SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR
LIMITATIONSOFINCIDENTALANDCONSEQUENTIALDAMAGES
ORLIMITATIONSONHOWLONGANIMPLIEDWARRANTYLASTS,
SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR
CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE.
Note: On porcelain enamel finished external parts and accessories
The Company offers no Warranty on chipping of enamel surfaces.
Inspect all product prior to accepting it for any damage to the enamel.
The salt air environment of coastal areas or a high humidity
environment can be corrosive to the porcelain enamel finish. These
conditions can cause rusting of the cast iron beneath the porcelain
enamel finish, which will cause the finish to flake off.
•
•
•
•
Allotherwarranties-expressedorimplied-withrespecttotheproduct,
its components and accessories, or any obligations/liabilities on the
part of the Company are hereby expressly excluded.
Dye lot variations with replacement parts and/or accessories can
occur and are not covered by warranty.
The Company neither assumes, nor authorizes any third party to
assume on its behalf, any other liabilities with respect to the sale of
this CFM Specialty Home Products product
GLASS DOORS: Glass doors are covered for a period of one year.
Glass doors are not warranted for breakage due to misuse or
accident. Glass doors are not covered for discoloration or burned in
stains due to environmental issues, or improper cleaning and
maintenance.
The warranties as outlined within this document do not apply to
chimney components or other non CFM Specialty Home Products
accessories used in conjunction with the installation of this product..
Damage to the unit while in transit is not covered by this warranty but
is subject to claim against the common carrier. Contact the dealer
from whom you purchased your fireplace/stove (do not operate the
appliance as this might negate the ability to process the claim with the
carrier).
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be
cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar
mix and masonry cleaners may corrode the brass finish. The
Company will not be responsible for, nor will it warrant any brass parts
which are damaged by external chemicals or down draft conditions.
•
•
The Company will not be responsible for:
GAS VALVES: Gas valves are covered for a period of one year
a) Down drafts or spillage caused by environmental conditions such
as near-by trees, buildings, roof tops, hills, or mountains.
b) Inadequate ventilation or negative air pressure caused by
mechanical systems such as furnaces, fans, clothes dryers, etc.
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and
mechanical components of the burner assembly are covered for one
year. All steel tube burners are warranted for one year.
ACCESSORIES: Unless otherwise noted all components and CFM
Specialty Home Products company supplied accessories are covered for
a period of one year.
This warranty is void if:
a) The fireplace has been operated in atmospheres contaminated
by chlorine, fluorine, or other damaging chemicals.
b) The fireplace has been subjected to prolonged periods of
dampness or condensation
c) Any damages to the fireplace, combustion chamber, heat
exchangerorothercomponentsduetowater,orweatherdamage,
which is the result of but not limited to, improper chimney/venting
installation.
CONDITIONS AND LIMITATIONS
•
This new Dutchwest product must be installed by a competent,
authorized, service contractor. A licensed technician, as prescribed
by the local jurisdiction must perform any installation/service work. It
must be installed and operated at all times in accordance with the
Installation and Operating instructions furnished with the product.
Any alteration, willful abuse, accident, or misuse of the product shall
nullify this warranty.
d) Any alteration, willful abuse, accident, or misuse of the product
has occurred.
•
•
This warranty is non-transferable, and is made to the original owner,
provided that the purchase was made through an authorized supplier
of the Company.
IF WARRANTY SERVICE IS NEEDED…
1) Contactyoursupplier. Makesureyouhaveyourwarranty,
your sales receipt, and the model/serial number of your
CFM Specialty Home Products product.
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK
YOURSELF.
ThecustomermustpayforanyAuthorizedDealerin-hometravelfees
or service charges for in-home repair work. It is the dealers option
whether the repair work will be done in the customer’s home or in the
dealer’s shop.
•
If upon inspection, the damage is found to be the fault of the
manufacturer, repairs will be authorized at no charge to the customer
parts and/or labor.
2626
30002008
Download from Www.Somanuals.com. All Manuals Search And Download.
GARANTIE À VIE LIMITÉE
PRODUIT COUVERT PAR LA PRÉSENTE GARANTIE
Toutes cuisinières à gaz de Dutchwest ont équipé avec une Insta-Flamme un Brûleur en ceramique.
GARANTIE DE BASE
La société CFM Specialty Products (ci-après la « Société ») garantit
votre nouveau poêle/foyer au gaz Dutchwest contre tous défauts de
fabrication et de matières premières pour une période d’un an à
compter de la date d’achat, sous réserve des conditions et limitations
suivantes.
• Si, lors de l’inspection, on constate que les dommages sont la faute du
fabricant, les réparations, les pièces et la main-d’œuvre seront auto-
risées sans frais pour le client.
• Toute pièce et (ou) tout composant remplacé en vertu des dispositions
de la présente garantie est couvert pour une période de six mois ou
jusqu’à l’expiration de la garantie originale, selon la dernière des
éventualités à survenir.
• Cette garantie est limitée à la réparation ou au remplacement de toute
pièce trouvée défectueuse en matières premières ou main-d’oeuvre,
à condition que ladite pièce ait été sujette aux conditions normales
d’usage et de service, après que ledit défaut a été confirmé par une
inspection par la Société.
• La Société peut, à sa discrétion, se décharger entièrement de toutes
obligations se rapportant à cette garantie en remboursant le prix de
gros de toute pièce défectueuse.
• Tous les frais/dépenses d’installation, de main-d’oeuvre, de construc-
tion, de transport ou autres causés par toute pièce défectueuse, une
réparation, un remplacement ou autre, ne seront pas couverts en vertu
de la présente garantie, et la Société n’assume aucune responsabilité
pour ceux-ci. De plus, la Société ne pourra être tenue responsable de
tous dommages fortuits ou indirects, sauf là où prévu par la loi.
• CERTAINS PROVINCES NE PERMETTENT PAS L’EXCLUSION OU
LES LIMITATIONS RELATIVES AUX DOMMAGES CONSÉCUTIFS
OU INDIRECTS QUANT À LA DURÉE DE TOUTE GARANTIE IMPLI-
CITE, SI BIEN QU’IL EST POSSIBLE QUE LES LIMITATIONS
CI-DESSUS NE S’APPLIQUENT PAS DANS VOTRE CAS. LA PRÉ-
SENTE GARANTIE VOUS DONNE DES DROITS SPÉCIFIQUES, ET
IL EST POSSIBLE QUE VOUS AYEZ D’AUTRES DROITS QUI
PEUVENT VARIER D’UN ÉTAT À L’AUTRE.
• Toute autre garantie, expresse ou implicite, en ce qui a trait au produit
et ses composants et accessoires, ou toute obligation/responsabilité
de la part de la Société sont expressément exclues en vertu des
présentes.
• La Société n’assume et n’autorise personne à assumer, en son nom,
toute responsabilité en ce qui a trait à la vente de ce produit Dutchwest.
• Les garanties, telles qu’elles sont décrites dans le présent document,
ne s’appliquent pas aux composants de cheminée ni à d’autres
accessoires CFM Specialty Home Products utilisés conjointement
avec l’installation de ce produit.
GARANTIE À VIE PROLONGÉE
L’échangeur de chaleur, s’il y a lieu, ainsi que la chambre à combus-
tion de tout produit à gaz de la société Dutchwest sont garantis pour
la vie contre la perforation des parois. Tous les produits équipés d’un
brûleur en céramique Insta-Flame comprennent une garantie à vie
limitée de la plaque du brûleur en céramique. Les garanties sont
accordées à l’acheteur d’origine, le tout sujet à une preuve d’achat et
aux conditions et limitations suivantes :
GARANTIE DES COMPOSANTS
FONTE : Toutes les pièces en fonte externes et internes sont garanties
pour une période de trois ans.
Nota : Dans le cas des pièces et accessoires externes au fini en émail de
porcelaine, la Société n’offre aucune garantie quant à l’écaillage des
surfaces en émail. Avant d’accepter un produit, inspectez-le afin de
vous assurer que les surfaces en émail ne sont pas endommagées.
L’atmosphère saline des zones côtières ou les environnements à
forte humidité peuvent provoquer la corrosion du fini en émail de
porcelaine. Ces conditions peuvent également faire rouiller la fonte
sous le fini en émail de porcelaine, provoquant ainsi l’écaillement de
la couche de fini.
Dans le cas des pièces et (ou) des accessoires de remplacement, les
variations de lots de teinture sont possibles, mais elles ne sont pas
couvertes par la garantie.
PORTES EN VERRE : Les portes en verre sont couvertes pour une
période d’un an. Les portes en verre ne sont pas garanties contre le bris
causé par un mauvais usage ou un accident. Les portes en verre ne sont
pas couvertes contre la décoloration ni contre les taches imprégnées
attribuables à des conditions environnementales ou à un nettoyage et un
entretien inadéquats.
PIÈCES ET ACCESSOIRES PLAQUÉS EN LAITON : Les pièces en
laiton ne doivent être nettoyées qu’avec de l’essence de citron. Les
nettoyants pour le laiton ne doivent pas être utilisés, et les agents
nettoyants pour le mortier et la maçonnerie peuvent provoquer la corro-
sion du fini laiton. La Société ne pourra être tenue responsable des
dommages à toute pièce en laiton occasionnés par des conditions
chimiques externes ou le refoulement, et elle n’offre aucune garantie à
cet égard.
• Les dommages causés à l’unité tandis qu’elle est en transit ne sont pas
couverts par la présente garantie, mais pourront être l’objet d’une
réclamation contre le transporteur général. Communiquez avec le
détaillant chez qui vous avez acheté votre foyer/poêle (n’utilisez pas
l’appareil étant donné que cela pourrait annuler toute réclamation
contre le transporteur).
• La Société n’engagera aucune responsabilité quant :
a) au refoulement de cheminée ou débordement causé par les condi-
tions environnementales (arbres, édifices, toits, coteaux ou monta-
gnes adjacents);
SOUPAPES À GAZ : Les soupapes à gaz sont couvertes pour une
période d’un an.
COMPOSANTS ÉLECTRONIQUES ET MÉCANIQUES : Les compo-
sants électroniques et mécaniques du brûleur sont couverts pendant un
an. Tous les brûleurs en acier sont garantis pendant un an.
ACCESSOIRES : À moins d’indication contraire, tous les composants et
accessoires fournis par CFM Specialty Home Products sont couverts
pendant une période d’un an.
b) à une ventilation inadéquate ou une pression d’air négative causée
par des systèmes mécaniques comme les fournaises, les ventila-
teurs, les sécheuses, etc.
CONDITIONS ET LIMITATIONS
• Ce nouveau produit Dutchwest doit être installé par un entrepreneur
de service autorisé et compétent. L’installation/le service doivent être
assurés par un technicien breveté, conformément à la juridiction
locale. Le produit doit être installé et utilisé en tout temps selon les
instructions d’installation et de fonctionnement fournies avec le pro-
duit. Toute altération ou tout abus volontaire, accident ou mauvais
usage du produit annulera cette garantie.
• Cette garantie n’est pas transférable et est offerte à l’acheteur d’ori-
gine, à condition que l’achat ait été effectué par l’entremise d’un
détaillant autorisé de la Société.
• Cette garantie est nulle si :
a) le foyer a été utilisé dans une atmosphère contaminée par du
chlore, du fluor ou tout autre produit chimique;
b) le foyer est assujetti à de longues périodes d’humidité ou de
condensation;
c) des dommages sont causés au foyer, à la chambre de combustion,
à l’échangeur de chaleur ou aux autres composants par de l’eau
ou par la température qui est le résultat mais sans y être limité,
d’une mauvaise installation de cheminée/ventilation;
d) toutealtérationainsiquetout abus volontaire, accident oumauvais
usage du produit annule la présente garantie.
• Le client doit assumer les frais de déplacement à domicile de tout
détaillant autorisé ou les frais de service relatifs à toute réparation
effectuée à domicile. Le détaillant peut à son choix effectuer les
réparations chez le client ou à son atelier.
SI UN SERVICE SOUS GARANTIE EST REQUIS…
1) Communiquez avec votre détaillant. Assurez-vous que vous avez
votre garantie, votre reçu de caisse ainsi que le numéro de modèle/
série de votre produit CFM Specialty Home Products.
2) NE TENTEZ PAS D’EFFECTUER DES RÉPARATIONS VOUS-
MÊME.
30002008
27
Download from Www.Somanuals.com. All Manuals Search And Download.
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
© CFM Specialty Home Products
Download from Www.Somanuals.com. All Manuals Search And Download.
|