Bryant Furnace 367AAN User Manual

LOW-BOY  
OIL FURNACE  
367AAN  
Sizes 105 & 120  
Series A  
FEATURES  
Low-Boy Design—The compact low-boy, dedicated upflow  
design is ideal for installation in basements where overhead  
space is limited.  
The model 367AAN is available in 2 sizes. Each size is  
capable of 3 heat/airflow combinations by a simple nozzle  
change. Unit 036105 covers inputs of 70,000, 91,000 and  
105,000 Btuh, and unit 060120 covers inputs of 119,000,  
140,000 and 154,000 Btuh. This eliminates the need to stock 6  
separate units.  
Venting—The 367AAN has a rear flue outlet. The unit may be  
vented using Type L vent material and a factory-approved or  
masonry chimney. It may also be sidewall vented with an  
approved power venter.  
Combustion Chamber/Heat Exchanger—The unique combi-  
nation combustion chamber/heat exchanger is made mainly of  
stainless and aluminized steel for durability and long life. Its  
heat transfer properties make it highly efficient. All seams are  
tightly welded for leak-free operation.  
Warranties—Limited Lifetime Warranty on combustion  
chamber/heat exchanger. Five-year Warranty on Beckett  
burner. Two-year Warranty on Honeywell ignition control.  
Contact your dealer for details.  
Beckett Oil Burner and Honeywell Controls—High quality  
Beckett oil burner allows safe and efficient combustion of oil.  
Honeywell ignition control and fan timer board provide for  
reliable operation and easy connection of thermostat and  
accessory wiring.  
Casing—Made of 18 gage painted steel for years of durability.  
The cabinet features an insulated enclosure for the burner and  
controls.  
LOW-BOY  
OIL FURNACE  
Insulation and Soundproofing—A unique silencer along with  
insulated walls and rubber blower mounts efficiently controls  
combustion noise and vibrations and makes this unit 1 of the  
quietest on the market.  
The model 367AAN combines high efficiency and quiet  
operation with the latest in oil heating technology. The  
367AAN is available in 2 sizes. Each size allows for 3 possible  
input capacities by a simple nozzle change. The furnace  
design is a low-boy style for upflow applications, especially  
where space is limited. The components of the 367AAN are  
the best available. The 367AAN features a Beckett oil burner  
and a Honeywell ignition control and fan timer board. The  
367AAN is among the most efficient and quietest oil furnaces  
available and will provide years of quality service. As with  
other Bryant furnaces, this model is designed to work as part  
of a total home comfort system which includes elements for  
cooling, air cleaning, humidification, ventilation, and zoning.  
Adjustable Blower Speed—Four-speed blower for precise  
airflow selection of heating or cooling operation.  
Constant Low-Speed Blower Switch—Allows continual low-  
speed air circulation through the home to maximize comfort  
while maintaining efficiency. Air is constantly filtered and  
stagnant air is reduced.  
Certifications—The 367AAN is UL and ULC certified. The  
efficiency rating is GAMA certified.  
Form No. PDS 367A.105.2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
UNIT SIZE  
036105  
060120  
SHIPPING WEIGHT (Lb)  
RATINGS AND PERFORMANCE  
Input Btuh  
235  
260  
70,000  
91,000  
74,000  
105,000  
85,000  
119,000  
98,000  
140,000  
115,000  
154,000  
125,000  
Output Capacity*  
Nonweatherized ICS  
57,000  
Nozzle—100 psig Pump Pressure  
Firing Rate (GPH)  
0.50—70W 0.65—70W 0.75—70B 0.85—70B 1.00—70W 1.10—70W  
0.50  
81.4  
0.65  
81.4  
0.75  
81.4  
0.85  
80.6  
1.00  
80.6  
1.10  
80.6  
AFUE%*  
Nonweatherized ICS  
Certified Temperature Rise Range °F  
Recommended Heating Blower Speed  
Heating CFM @ 0.2-in. wc Static Pressure  
Cooling CFM @ 0.5-in. wc Static Pressure  
ELECTRICAL  
55—85  
Med-Low  
840  
55—85  
Med-High  
1130  
55—85  
High  
55—85  
Med-Low  
1220  
55—85  
Med-High  
1555  
55—85  
High  
1425  
1250  
1890  
1865  
1250  
1250  
1865  
1865  
Unit Volts—Hertz—Phase  
Operating Voltage Range Min—Max†  
Maximum Unit Amps  
115—60—1  
104—132  
15.7  
20  
12.2  
15  
Minimum Wire Size (AWG)  
Maximum Wire Length (Ft)‡  
Maximum Fuse or Ckt Bkr Amps**  
Transformer (24v)  
14  
26  
40va  
40va  
External Control  
Heating  
Cooling  
Power Available  
30va  
Air Conditioning Blower Relay  
BURNER AND CONTROLS  
Standard  
Beckett  
AFG-F6  
Beckett AFG-F3  
Burner Model (3450 RPM)***  
Beckett AFG-F3  
Oil Pump Stages  
1
Ignition Control  
Continuous  
Heating Blower Control (Off Delay)  
BLOWER DATA  
Selectable 60, 90, 120, or 150 Sec  
3/4  
9.5  
Direct-Drive Motor HP (PSC)  
Motor Full Load Amps  
1/3  
6.2  
RPM (Nominal)—Speeds  
Blower Wheel Diameter X Width (In.)  
Filter Size (In.)—Disposable  
1075—4  
12 X 10  
10 X 8  
(2) 16 X 20 X 1  
(2) 12 X 20 X 1  
FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS  
Electronic Air Cleaner  
AIRA  
902B  
Mechanical Air Cleaner  
Air Cleaner Cabinet  
KEACA  
Humidifier  
Model 912D, 912E, 913B, 913C, or 914A  
Model VA3B, VB5B, or VC5B  
Model VL3A  
Heat Recovery Ventilator  
Energy Recovery Ventilator  
Thermostat—Non-Programmable  
For Use with 1-Speed Air Conditioner—TSTATBBNAC01-A  
For Use with 2-Speed Air Conditioner—TSTATBBN2S01-A  
For Use with 2-Speed Heat Pump—TSTATBBN2S01-A  
Thermostat—Programmable  
For Use with 1-Speed Air Conditioner—TSTATBBPAC01-A  
For Use with 2-Speed Air Conditioner—TSTATBBP2S01-A  
For Use with 1-Speed Heat Pump—TSTATBBPDF01-A  
For Use with 2-Speed Heat Pump—TSTATBBP2S01-A or TSTATBBPDF01-A  
Zoning—2-Zone  
ZONEKIT2ZBDP, ZONEBB2KIT01  
Zoning—4-Zone  
ZONEBB4KIT01  
Zoning—8-Zone  
ZONEBB8KIT01  
OIL NOZZLE KIT†† (QTY-50)  
OIL NOZZLE KIT†† (QTY-50)  
OIL NOZZLE KIT†† (QTY-50)  
OIL NOZZLE KIT‡‡ (QTY-50)  
OIL NOZZLE KIT‡‡ (QTY-50)  
OIL NOZZLE KIT‡‡(QTY-50)  
0.50 GPH For 70,000 Btuh — KLANZ0150050  
0.65 GPH For 91,000 Btuh — KLANZ0250065  
0.75 GPH For 105,000 Btuh — KLANZ0350075  
0.85 GPH For 120,000 Btuh — KLANZ0450085  
1.00 GPH For 140,000 Btuh — KLANZ0550100  
1.10 GPH For 154,000 Btuh — KLANZ0650110  
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.  
† Permissible voltage limits for proper furnace operation.  
‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.  
** Time-delay fuse recommended.  
*** Beckett AFG-F6 requires field supplied and replacement burner firing head.  
†† For unit 036105  
‡‡ For unit 060120  
ICS—Isolated Combustion System  
PSC—Permanent Split Capacitor  
As Factory Shipped.  
—3—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AIR DELIVERY—CFM (With Filter)  
EXTERNAL STATIC PRESSURE IN. WC  
UNIT  
SIZE  
BLOWER  
SPEED  
0.2  
0.3  
0.4  
0.5  
0.6  
1170  
885  
0.7  
1030  
820  
0.8  
925  
0.9  
805  
670  
500  
665  
1335  
1215  
940  
655  
High  
Med-High  
Med-Low  
Low  
1425  
1130  
840  
1350  
1045  
810  
1305  
1000  
770  
1250  
950  
745  
036105  
060120  
740  
685  
635  
580  
725  
730  
740  
745  
730  
715  
690  
High  
2080  
1890  
1555  
1220  
2040  
1860  
1475  
1165  
1965  
1770  
1395  
1080  
1865  
1675  
1320  
1000  
1700  
1550  
1210  
925  
1575  
1450  
1135  
855  
1475  
1330  
1050  
780  
Med-High  
Med-Low  
Low  
SERVICE TRAINING  
Packaged Service Training programs are an excellent way to increase your  
knowledge of the equipment discussed in this manual, including:  
• Unit Familiarization  
• Installation Overview  
• Maintenance  
• Operating Sequence  
A large selection of product, theory, and skills programs is available, using popular  
video-based formats and materials. All include video and/or slides, plus companion  
book.  
Classroom Service Training plus "hands-on" the products in our labs can mean  
increased confidence that really pays dividends in faster troubleshooting, fewer  
callbacks. Course descriptions and schedules are in our catalog.  
CALL FOR FREE CATALOG 1-800-962-9212  
[ ] Packaged Service Training  
[ ] Classroom Service Training  
A94328  
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE  
UNIT MUST BE INSTALLED IN ACCORDANCE  
WITH INSTALLATION INSTRUCTIONS  
Cancels: PDS 367A.105.1B  
—4—  
© 1998 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46206  
PRINTED IN U.S.A.  
Catalog No. 5236-700  
1-98  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Network Router F5D8236 4 User Manual
Belkin Network Router F506230 3 User Manual
Belkin Switch F1DP108Gea User Manual
Bionaire Air Cleaner BAP815 User Manual
Black Box Network Hardware AC603A User Manual
Blanco Indoor Furnishings 514 470 User Manual
Blaupunkt Car Amplifier PCA 2100 User Manual
Campbell Hausfeld Air Compressor FP2601 User Manual
Casio Digital Camera EX Z2200 User Manual
Christie Digital Systems Projector LW400 User Manual