Bryant Furnace 313AAV User Manual

313AAV/JAV Plus 80x  
4--Way Multipoise  
Induced Combustion Gas Furnace  
Input Capacities: 45,000 thru 135,000 Btuh, Series B  
Product Data  
STANDARD FEATURES  
S ECM blower motor included  
S Noise elimination combustion system  
S SmartEvapt can lower the humidity level in the home by  
nearly 10%  
S Certified to leak 2 percent or less of its nominal air  
conditioning CFM delivered when pressurized to 1--In.  
Water Gauge with all present air inlets, air outlets, and  
condensate drain port(s) sealed.  
S Four--position furnace: Upflow, Horizontal Right,  
Horizontal Left, Downflow  
Thirteen different vent options  
S Compact design only 33--1/3 in. (847 mm) tall  
S Microprocessor based “smart” control center  
Fan on Plust -- Continuous Fan speed adjustable from  
thermostat  
Adjustable heating air temperature rise  
Dehumidify mode  
Enhanced diagnostics with LED and reflective sight glass,  
non--volatile fault code memory, and self--test feature  
On--board fuse for transformer protection  
A10256  
S Patented blocked vent safeguard to ensure proper furnace  
THE BRYANT Plus 80x GAS FURNACE  
The Plus 80x Deluxe 4--Way Multipoise Gas Furnace offers  
outstanding features in an 80% AFUE furnace.  
venting  
S Insulated blower compartment  
Deluxe features include: an ECM motor which enhances SEER  
performance up to 1.5 points*, a third fan relay for discrete  
continuous fan speed, the ability to change continuous fan speeds  
from the thermostat (Fan on Plust), dehumidify mode, fault code  
storage, and more. The Plus 80x is very quiet thanks to a new  
combustion design that eliminates noise, rather than just muffle or  
box it in. Applications are easy with 4--way multipoise design,  
through--the--furnace downflow venting, 13 different venting  
options, and an overall design for easy service access. An inner  
blower door is provided for tighter sealing in sensitive applications.  
The 313JAV is approved for use in Low NOx Air Quality  
Management Districts.  
S HYBRID HEAT® Dual Fuel System compatible  
S All models are chimney friendly when used with accessory  
vent kit  
S Perfect Lightt Igniter  
S Residential installations eligible for consumer financing  
through the Comfort Credit Program  
*as compared to the Air Conditioning Heating and Refrigeration Institute’s standard coil---only ratings when paired with selected Bryant evaporator coils.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
BRYANT ACCESSORIES  
DESCRIPTION 313AAV/JAV  
PART NO.  
024045  
X
048070  
X
048090  
X
060110  
X
060135  
FILCABBB0016  
FILCABBB0020  
FILCABBB0024  
FILBBCAR0016  
FILBBCAR0020  
FILBBCAR0024  
EXPXXUNV0016  
EXPXXUNV0020  
EXPXXUNV0024  
EXPXXFIL0016  
EXPXXFIL0020  
EXPXXFIL0024  
KGAFR0401B14  
KGAFR0501B17  
KGAFR0601B21  
KGAFR0701B24  
KGAFR0801SRE  
KGAWF1301UFR {  
KGAWF1401UFR  
KGAWF1501UFR  
KGAWF1306UFR {  
KGAWF1406UFR  
KGAWF1506UFR  
KGAFE0112UPH  
KGASB0201ALL  
KGBVG0101DFG  
KGAVE0101DNH  
KGACA02014FC  
KGACA02015FC  
KGANP4601ALL  
KGAPN3901ALL  
KGALB0101KIT  
KGAHA0150N42  
Media Filter Cabinet  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Cartridge Media Filter  
EZ Flex Media Filter with End Caps  
Replacement EZ Flex Filter Media  
External Bottom Return  
X
X
X
S
X
X
S
Filter Rack  
X
X
External Side Return Filter Rack  
X
S
X
S
S
Unframed Filter 3/4---in. (19 mm)  
X
X
X
X
X
X
X
X
X
Flue Extension  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Combustible Floor Base  
Downflow Vent Guard  
Vent Extension Kit  
Chimney Adapter Kit  
Chimney Adapter Kit  
N a t u r a l --- t o --- P r o p a n e C o n v e r s i o n K i t *  
P r o p a n e --- t o --- N a t u r a l C o n v e r s i o n K i t *  
Label Kit  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KGAHA0250N43  
(factory supplied)  
KGAHA0350N44  
KGAHA0450N45  
KGAHA0550N46  
KGAHA1550N47  
KGAHA1650N48  
KGAHA0650P54  
KGAHA0750P55  
KGAHA0850P56  
KGAHA5750125  
KGAHA5750130  
Gas Orifice Kit (Qty 50)  
See Installation Instructions for model, altitude, and heat value usages.  
*Factory---authorized and field---installed. Gas conversion kits are CSA (AGA/CGA) recognized.  
{Suitable for Side Return Filter Rack.  
X
--- Accessor y  
S --- Stan dar d  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PHYSICAL DATA  
UNIT SIZE  
024045  
048070  
048090  
060110  
060135  
OUTPUT CAPACITY  
BTUH  
( N o n --- w e a t h e r i z e d I C S )  
313JAV Upflow; all 313AAV  
313JAV Downflow/Horizontal  
36,000  
53,000  
72,000  
90,000  
107,000  
34,000  
51,000  
69,000  
86,000  
102,000  
313JAV Upflow; all 313AAV  
313JAV Downflow/Horizontal  
N o n --- w e a t h e r i z e d IC S  
44,000  
42,000  
80.0  
66,000  
63,000  
80.0  
88,000  
84,000  
80.0  
110,000  
105,000  
80.0  
132,000  
126,000  
80.0  
INPUT BTUH  
AFUE%  
SHIPPING WEIGHT LB. (KG)  
104 (47)  
126 (57)  
140 (64)  
152 (69)  
163 (74)  
30---60  
( 1 7 --- 3 3 )  
25---55  
( 1 4 --- 3 1 )  
35---65  
( 1 9 --- 3 6 )  
30---60  
( 1 7 --- 3 3 )  
40---70  
( 2 2 --- 3 9 )  
CERTIFIED TEMP RISE RANGE ˚_F (_C)  
Heating  
Cooling  
Heating  
Cooling  
0.10  
0.50  
735  
0.12  
0.50  
1230  
1460  
0.15  
0.50  
1345  
1665  
SPST  
0.20  
0.50  
1890  
2040  
0.20  
0.50  
1865  
2070  
CERTIFIED EXT STATIC  
PRESSURE (IN. In. W.C.)  
AIRFLOW CFM  
1035  
LIMIT CONTROL  
HEATING BLOWER CONTROL  
BURNERS (Monoport)  
Solid---State Time Operation  
4
2
3
5
6
GAS CONNECTION SIZE  
1 / 2 --- in . N P T  
GAS VALVE(Redundant) Manufacturer  
Minimum Inlet Pressure (In. W.C.)  
Maximum Inlet Pressure (In. W.C.)  
IGNITION DEVICE  
W h it e --- R o d g e r s  
4.5 (Natural Gas)  
13.6 (Natural Gas)  
Hot Surface  
*Gas input ratings are certified for elevations to 2000 ft. (610 M)*. In USA, For elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305  
M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1---2009 Table F.4 or furnace Installation Instructions.  
{Capacity in accordance with U.S. Government DOE test procedures.  
}Airflow shown is for bottom only return---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each  
return---air supply. An airflow reduction of up to 7 percent may occur when using a Bryant 4---5/16 in. (110 mm) high efficiency media filter.  
ICS --- Isolated Combustion System  
BLOWER PERFORMANCE DATA  
UNIT SIZE  
024045  
1/2  
6.8  
048070  
3/4  
8.4  
048090  
3/4  
8.4  
060110  
1
10.9  
060135  
1
10.9  
DIRECT---DRIVE MOTOR Hp (ECM --- 5 Speed)  
MOTOR FULL LOAD AMPS  
R P M ( N o m i n a l ) --- S P E E D S  
1050---5  
1050---5  
1050---5  
1050---5  
1050---5  
10 x 6  
(254 x 152)  
11 x 8  
(279 x 203)  
10X10  
(254 x 254)  
11 x 11  
(279 x 279)  
11 x 11  
(279 x 279)  
BLOWER WHEEL DIAMETER x WIDTHS --- IN (MM)  
A02169  
A02169  
A08063  
A02170  
HEAT EXCHANGER  
CONTROL BOARD  
INDUCER BLOWER  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEE NOTES: 1,2,3,4,7,8,9  
SEE NOTES: 1,2,4,5,7,8,9  
SEE NOTES: 1,2,4,7,8,9  
UPFLOW  
DOWNFLOW  
UPFLOW  
A02061  
A02058  
A02059  
SEE NOTES:1,2,3,4,5,7,8,9  
DOWNFLOW  
SEE NOTES: 1,2,3,4,7,8,9  
DOWNFLOW  
SEE NOTES: 1,2,4,5,6,7,8,9  
DOWNFLOW  
A02062  
A02060  
A02063  
Venting Notes  
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC),  
NFPA54/ANSI Z223.1.  
2. Immediately increase to 5--in. (127 mm) vent connector outside furnace casing when 5--in. (127 mm) vent connector required, refer to  
Note 1.  
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when  
Downflow Vent Guard is used in downflow position.  
4. Type B vent where required, refer to Note 1.  
5. 4--in. (102 mm) single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit.  
6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration.  
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit for sizing and complete  
application details.  
8. Secure vent connector to furnace elbow with (2) corrosion--resistant sheet metal screws, space approximately 180_ apart.  
9. Secure all other single wall vent connector joints with (3) corrosion--resistant screws spaced approximately 120_ apart. Secure Type B  
vent connectors per vent connector manufacturer’s recommendations.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL RIGHT  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL RIGHT  
A02068  
A02070  
SEE NOTES: 1,2,4,7,8,9  
HORIZONTAL RIGHT  
A02069  
SEE NOTES: 1,2,4,7,8,9  
HORIZONTAL LEFT  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL LEFT  
A02064  
A02065  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL LEFT  
SEE NOTES: 1,2,4,5,7,8,9  
HORIZONTAL LEFT  
A02067  
A02066  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
AIR DELIVERY -- CFM (WITH FILTER)*  
EXTERNAL STATIC PRESSURE (In. W.C.)  
RETURN---AIR  
UNIT SIZE  
SPEED  
SUPPLY  
0.1  
0.2  
0.3  
0.4  
1075  
800  
0.5  
1035  
755  
0.6  
980  
720  
0.7  
905  
680  
0.8  
820  
645  
0.9  
720  
1
580  
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
1185  
920  
735  
820  
650  
1145  
880  
685  
765  
595  
1585  
1360  
1200  
1140  
985  
1800  
1545  
1320  
1160  
1030  
2205  
1525  
1890  
1340  
1205  
2240  
1660  
1865  
1575  
1355  
1115  
835  
605  
540  
Bottom or  
Side(s)  
024045  
625  
585  
530  
490  
435  
395  
345  
295  
725  
670  
630  
580  
545  
490  
455  
405  
535  
490  
430  
390  
330  
280  
235  
--- ---  
1625  
1405  
1240  
1190  
1035  
1845  
1590  
1365  
1225  
1100  
2255  
1600  
1945  
1420  
1280  
2295  
1725  
1910  
1630  
1430  
1535  
1320  
1155  
1095  
930  
1495  
1280  
1110  
1050  
885  
1460  
1240  
1065  
1000  
835  
1415  
1195  
1020  
955  
1365  
1155  
975  
915  
745  
1295  
1115  
935  
870  
695  
1220  
1070  
895  
1125  
1030  
850  
Bottom or  
Side(s)  
048070  
048090  
060110  
060135  
830  
790  
785  
650  
600  
1755  
1500  
1270  
1110  
960  
1710  
1455  
1215  
1060  
875  
1665  
1410  
1170  
1010  
805  
1595  
1365  
1125  
950  
1500  
1315  
1070  
895  
1400  
1270  
1025  
830  
1275  
1180  
955  
1105  
1000  
900  
Bottom or  
Side(s)  
770  
710  
730  
645  
570  
505  
425  
2150  
1465  
1830  
1280  
1140  
2185  
1605  
1800  
1510  
1285  
2100  
1400  
1770  
1200  
1055  
2125  
1545  
1745  
1435  
1200  
2040  
1335  
1715  
1140  
990  
2070  
1460  
1685  
1365  
1125  
1985  
1275  
1655  
1065  
910  
2005  
1395  
1610  
1300  
1075  
1920  
1210  
1600  
1005  
840  
1925  
1340  
1545  
1245  
1015  
1835  
1150  
1545  
925  
1735  
1080  
1480  
865  
1615  
1015  
1430  
790  
Bottom or  
Side(s)  
760  
695  
630  
1805  
1285  
1485  
1185  
945  
1670  
1230  
1435  
1130  
855  
1545  
1170  
1380  
1065  
800  
Bottom or  
Side(s)  
*A filter is required for each return---air inlet. Airflow performance included 3/4---in. (19 mm) washable filter media such as contained in factory ---authorized ac-  
cessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.  
--- --- Indicates unstable operating conditions.  
ELECTRICAL DATA  
OPERATING VOLTAGE  
V O LT S ---  
H E R T Z ---  
PHASE  
MAXIMUM FUSE  
OR CKT BKR  
AMPS{  
UNIT  
SIZE  
MAXIMUM  
MAXIMUM WIRE  
MINIMUM  
WIRE GAGE  
RANGE*  
UNIT AMPS  
LENGTH FT (M)}  
Maximum  
127  
Minimum  
104  
024045  
048070  
048090  
060110  
060135  
1 1 5 --- 6 0 --- 1  
1 1 5 --- 6 0 --- 1  
1 1 5 --- 6 0 --- 1  
1 1 5 --- 6 0 --- 1  
1 1 5 --- 6 0 --- 1  
8.1  
9.5  
10.3  
13.1  
13.1  
34 (10)  
29 (9)  
27 (8)  
34 (10)  
34 (10)  
15  
15  
15  
20  
20  
14  
14  
14  
12  
12  
127  
104  
127  
104  
127  
104  
127  
104  
* Permissible limits of the voltage range at which the unit operates satisfactorily.  
{ Time---delay type is recommended.  
}Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIMENSIONS  
5.1  
[130.5]  
2 1/16  
[51.6]  
1.7  
[43.5]  
C
Ø7/8  
[22.2]  
ACCESSOORY (2)  
8 5/8  
[219]  
6 13/16  
[172.3]  
5 7/8  
1 15/16  
[49.2]  
[148.5] 5 5/8  
AIR FLOW  
AIR FLOW  
[143.3]  
2 5/16  
5 7/16  
[138.5]  
5 15/16  
[150.7]  
5 1/2  
[140.3]  
3 7/16  
[86.8]  
5 7/8  
[148.5]  
[59]  
A
B
19  
[481.7]  
OUTLET  
1 15/16  
[49.2]  
AIR FLOW  
TOP OF CASING  
TOP OF CASING  
4 13/16  
[122.2]  
Ø1/2  
Ø7/8  
[22.2]  
JUNCTION BOX  
LOCATION  
Ø7/8  
[22.2]  
[12.7]  
7 13/16  
[197.8]  
8 7/16  
[213.5]  
9 11/16  
[245.4]  
THERMOSTAT WIIRE ENTRY  
9 9/16  
[243.3]  
ACCESSORY  
11 7/16  
[290.7]  
Ø1 3/4  
9 7/8  
[250.7]  
[44.5]  
GAS ENTRY  
Ø7/8  
[22.2]  
27 3/4  
[704.7]  
Ø1/2  
[12.7]  
J.BOX PPROVISION  
Ø7/8  
Ø1 3/4  
27 3/4  
[704.7]  
29 9/16  
[750.7]  
[44.5]  
THERMOSTAT WIIRE ENTRY  
[22.2]  
ACCESSORY  
GAS ENTRY  
33 1/4  
[843.9]  
14 7/8  
Ø7/8  
[337.3]  
[22.2]  
(BOTH SIDES)  
ACCESSORY  
Ø7/8  
[22.2]  
ACCESSORY  
KNOCK OUUTS FOR  
VENTING(5  
PLACES)  
21.6  
6.1  
[155.7]  
1 1/4  
D
3/4  
[19.1]  
[549.5]  
[31.8]  
22 1/16  
1
BOTTOM RRETURN  
WIDTH  
BOTTOMM INLET  
[560]  
[25.4]  
28.39  
SIDE INLET  
(BOTH SSIDES)  
[721.2]  
29  
[736.9]  
A10271  
1. Two additional 7/8--in. (22 mm) dia. knockouts are located in the top plate.  
2. Minimum return--air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.  
3. Minimum return--air opening at furnace.  
a. For 800 CFM--16--in. (406 mm) round or 14--1/2 x 12--in. (368 x 305 mm) rectangle.  
b. For 1200 CFM--20--in. (508 mm) round or 14--1/2 x 19--1/3 in. (368 x 491 mm)rectangle.  
c. For 1600 CFM--22--in. (559 mm) round or 14--1/2 x 22--1/16--in. (368 x 560 mm) rectangle.  
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a  
combination of 1 side and the bottom, or the bottom of single side inlets. The use of both side inlets, a combination of one side and the bottom, or the bottom only  
will ensure adequate return air openings for airflow requirements above 1800 CFM.  
A
B
C
D
VENT  
CONNECTION  
SIZE  
ACCESSORY-  
MEDIA CABINET  
SIZE  
CABINET  
WIDTH  
IN (MM)  
OUTLET WIDTH  
IN (MM)  
TOP & BOTTOM  
FLUE COLLAR  
IN (MM)  
BOTTOM INLET  
WIDTH  
FURNACE SIZE  
IN (MM)  
IN (MM)  
024045  
048070  
048090  
060110  
060135  
14---3/16 (360)  
17---1/2 (445)  
21 (533)  
12---9/16 (319)  
15---7/8 (403)  
19---3/8 (492)  
19---3/8 (492)  
22---7/8 (581)  
9---5/16 (237)  
11---9/16 (294)  
13---5/16 (338)  
13---5/16 (338)  
15---1/16 (383)  
12---11/16 (322)  
16---1/8 (410)  
19---1/2 (495)  
19---1/2 (495)  
23 (584)  
4
4
16 (406)  
16 (406)  
20 (508)  
20 (508)  
24 (610)  
4
21 (533)  
4
24---1/2 (622)  
4*  
*135 size furnaces require a 5 or 6---in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete  
installation requirements.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
A10269  
G
F
E
N
I
D
Always Ask For  
Use of the AHRI Certified TM Mark indicates a  
manufacturer’s participation in the program. For  
verification of certification for individual products,  
C
E D  
E
R
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPICAL WIRING SCHEMATIC  
FIELD 24-V WIRING  
FIELD 115-, 208/230-, 460-V WIRING  
FACTORY 24-V WIRING  
FACTORY 115-V WIRING  
NOTE 2  
THERMOSTAT  
TERMINALS  
W
C
R
G
Y
FIVE WIRE  
FIELD-SUPPLIED  
DISCONNECT  
THREE-WIRE  
HEATING-ONLY  
208/230- OR  
460-V  
BLOWER DOOR SWITCH  
THREE  
PHASE  
W
R
BLK  
BLK  
C
O
N
T
R
O
L
WHT  
WHT  
208/230-V  
SINGLE  
PHASE  
GND  
GND  
G
AUXILIARY  
J-BOX  
115-V FIELD-  
SUPPLIED  
DISCONNECT  
COM  
Y/Y2  
GND  
NOTE 1  
CONDENSING  
UNIT  
TWO  
WIRE  
24-V  
TERMINAL  
BLOCK  
NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation.  
2. Some thermostats require a "C" terminal connection as shown.  
3. If any of the original wire, as supplied, must be replaced, use  
same type or equivalent wire.  
FURNACE  
A99440  
MODEL NUMBER NOMENCLATURE  
066  
V
A
135  
A
E
313  
A
JA  
Bryant Type Code  
Gas Furnace, 4---Way  
Multipoise, 80%  
F i x e d --- C a p a ci t y  
Model Code  
A = Standard  
J = Low NOx  
Variations  
Series  
A
B
Electrical Supply  
A = 110 to 125 Volts  
Brand Name  
A --- C o mmo n U ni t  
Variations  
Heating Size  
000 --- None  
050 --- Heating Input  
005 --- Electrical Output  
105 --- Oil Input  
Cooling Size  
000 --- None  
014 --- 14,000 Btuh  
018 --- 18,000 Btuh  
024 --- 24,000 Btuh  
037 --- Boiler Size  
012 --- Air  
060 --- Humidifiers  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GUIDE SPECIFICATIONS  
Gas Furnace  
313AAV/JAV  
GENERAL  
System Description  
Inducer Motor  
Furnish a _________________ fixed capacity gas--fired furnace  
for use with natural gas or propane (factory authorized conversion  
kit required for propane); furnish cold air return plenum.  
Inducer motor shall be soft mounted to reduce vibration  
transmission.  
Draft Safeguard Switch  
Quality Assurance  
Unit will be designed, tested and constructed to the current ANSI Z  
21.47/CSA 2.3 design standard for gas--fired central furnaces.  
Draft Safeguard Switch (blocked vent safeguard) shall be factory  
installed to reduce the possibility of vent gas infiltration due to a  
blocked or restricted vent pipe.  
Unit will be 3rd party certified by CSA to the current ANSI Z  
21.47/CSA 2.3 design standard for gas--fired central furnaces.  
Heat Exchangers  
Heat exchangers shall be a 4--Pass 20 gage aluminized steel of  
fold--and--crimp sectional design when applied operating under  
negative pressure.  
Unit will carry the CSA Blue Star® label.  
Unit efficiency testing will be performed per the current DOE test  
procedure as listed in the Federal Register.  
Unit will be certified for capacity and efficiency and listed in the  
latest AHRI Consumer’s Directory of Certified Efficiency Ratings.  
Controls  
Control shall include a micro--processor based integrated electronic  
control board with at least 11 service troubleshooting codes  
displayed via enhanced flashing LED diagnostic light on the  
control, a self--test feature that checks all major functions of the  
furnace within one minute, and a replaceable automotive--type  
circuit protection fuse. Multiple operational settings available  
including, separate blower speeds for heating, cooling and  
continuous fan. Continuous fan speed may be adjusted from the  
thermostat. Features will also include temporary reduced airflow in  
Unit will carry the current Federal Trade Commission Energy  
Guide efficiency label.  
Delivery, Storage and Handling  
Unit shall be shipped as single package only and is stored and  
handled per unit manufacturer’s recommendations.  
Warranty (for inclusion by specifying engineer)  
the cooling mode for improved dehumidification when  
a
U.S. only. Warranty certificate available upon request.  
Thermidistatt Control is selected as the thermostat.  
PRODUCTS  
Equipment  
Components shall include: slow--opening gas valve to reduce  
ignition noise, regulate gas flow, with electric switch gas shut--off;  
flame proving sensor, hot surface igniter, pressure switch assembly;  
flame rollout switch, blower and inducer assembly, 40va  
transformer; low--voltage (heating) (heating/ cooling) thermostat.  
Operating Characteristics  
Heating Capacity shall be ________ Btuh input; ________ Btuh  
output capacity.  
Fuel Gas Efficiency shall be 80% AFUE.  
Air delivery shall be ___________ CFM minimum at 0.50 In.  
W.C. external static pressure.  
Dimensions shall be: depth __________ in.; width _________ in;  
height_________in. (mm) (casing only). Height shall  
be_________in. (mm) with A/C coil and _____________in. (mm)  
overall with plenum.  
Blower Wheel and Blower Motor  
Galvanized blower wheel shall be centrifugal type, statically and  
dynamically balanced. Blower motor of ECM type shall be  
permanently lubricated with sealed bearings, of _______hp, and  
shall be multiple--speed direct drive. Blower motor shall be soft  
mounted to the blower scroll to reduce vibration transmission.  
Electrical Requirements  
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).  
Minimum wire size shall be_________AWG; maximum fuse size  
or circuit breaker shall be __________Amps.  
Filters  
Furnace may have reusable--type filters. Filter shall be _______ in  
(x) _______in. (mm). An accessory high--efficiency media filter is  
available as an option. _______________ Media Filter.  
Special Features  
Refer to section of the product data sheet identifying accessories  
and descriptions for specific features and available enhancements.  
Casing  
Casing shall be of .030 in. (.76 mm) thickness minimum,  
pre--painted galvanized steel.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
0 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231  
Printed in U.S.A.  
Edition Date: 09/10  
Catalog No. PDS313AAV--- 0 5  
Replaces: PDS313AAV---04  
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bionaire Humidifier BCM1855 User Manual
Black Box Switch express ethernet switch User Manual
Black Decker Iron F611 User Manual
Bose Stereo System 323699 0010 User Manual
Braun Iron SI6285 User Manual
Breville Juicer JE95XL User Manual
Casablanca Fan Company Fan 46U26D User Manual
Century Welding System IM998 User Manual
Chicago Electric Portable Generator 90300 User Manual
Cisco Systems Model Vehicle 2960 User Manual