116B
Legacyt Line 16 Air Conditioner
with Puronr Refrigerant
1--1/2 to 5 Nominal Tons
Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
14 -- 16.5 SEER/11.0-- 13.5 EER
S
Microtube Technologyt refrigeration system
Indoor air quality accessories available
S
Sound
S
Sound level as low as 76 dBA
S
Sound level as low as 74 dBA with accessory sound
blanket
Comfort
S
System supports Edger Thermidistatt or standard
thermostat controls
Reliability
S
Puronr refrigerant -- environmentally sound, won’t
deplete the ozone layer and low lifetime servce cost.
S
S
S
S
S
Scroll compressor
Internal pressure relief valve
Internal thermal overload
the environmentally sound refrigerant
Filter drier
Balanced refrigeration system for maximum reliability
Bryant’s Air Conditioners with Puronr refrigerant provide a
collection of features unmatched by any other family of
equipment. The 116B has been designed utilizing Bryant’s Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth’s ozone
layer.
Durability
DuraGuardt protection package:
S
S
S
Solid, durable sheet metal construction
Dense wire coil guard standard
This product has been designed and manufactured to meet
Energy Starr criteria for energy efficiency when matched with
appropriate coil components. Refer to the combination ratings in
the Product Data for system combinations that meet Energy Starr
guidelines.
Baked--on, complete outer coverage, powder paint
Applications
S
Long--line -- up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
information.
S
Low ambient (down to --20_F/--28.9_C)) with
accessory kit
Download from Www.Somanuals.com. All Manuals Search And Download.
REFRIGERANT PIPING LENGTH LIMITATIONS
{
Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puronr Refrigerant:
The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and
outdoor units.
See Table below for liquid line sizing and maximum lengths :
Maximum Total Equivalent Length
Outdoor Unit BELOW Indoor Unit
Liquid
Line
Diam.
w/ TXV
AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit BELOW Indoor
Liquid Line
Connection
Vertical Separation ft (m)
Size
0 --- 5
(0---1.5)
6 --- 1 0
(1.8---3.0)
11---20
(3.4---6.1)
21---30
(6.4---9.1)
31---40
(9.4---12.2)
41---50
(12.5---15.2)
51---60
(15.5---18.3)
61---70
(18.6---21.3)
71---80
(21.6---24.4)
1/4
5/16
3/8
1/4
5/16
3/8
1/4
5/16
3/8
150
250*
250*
75
250*
250*
30
150
250*
250*
75
250*
250*
--- ---
125
250*
250*
75
250*
250*
--- ---
100
250*
250*
50
250*
250*
--- ---
100
250*
250*
50
250*
250*
--- ---
75
--- ---
250*
250*
--- ---
175
250*
--- ---
--- ---
225*
250*
--- ---
125
250*
--- ---
--- ---
150
250*
--- ---
100
250*
--- ---
18000
AC with
Puron
3/8
3/8
3/8
250*
250*
--- ---
225*
250*
--- ---
24000
AC with
Puron
30000
AC with
Puron
175
250*
225*
250*
200
250*
175
250*
125
250*
100
250*
75
250*
--- ---
250*
--- ---
250*
36000
AC with
Puron
42000
AC with
Puron
48000
AC with
Puron
49000
AC with
Puron
60000
AC with
Puron
61000
AC with
Puron
5/16
3//8
5/16
3/8
175
250*
125
150
250*
100
150
250*
100
100
250*
75
100
250*
75
100
250*
50
75
--- ---
250*
--- ---
--- ---
250*
--- ---
3/8
3/8
3/8
3/8
3/8
3/8
250*
--- ---
250*
250*
250*
250*
250*
250*
250*
250*
150
3/8
3/8
3/8
3/8
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
225*
225*
250*
250*
190
250*
250*
150
230
230
110
110
160
160
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
190
150
*
{
Maximum actual length not to exceed 200 ft (61 m)
Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.
--- --- = o u t s i d e a c c e p t a b l e r a n g e
Maximum Total Equivalent Length
Outdoor Unit ABOVE Indoor Unit
Liquid
Line
Diam.
w/ TXV
AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit ABOVE Indoor
Liquid Line
Size
Vertical Separation ft (m)
Connection
25
(7.6)
26---50
(7.9---15.2)
51---75
(15.5---22.9)
76---100
(23.2---30.5)
101---125
(30.8---38.1)
126---150
(38.4---45.7)
151---175
(46.0---53.3)
176---200
(53.6---61.0)
1/4
5/16
3/8
1/4
5/16
3/8
1/4
5/16
3/8
175
250*
250*
100
250*
250*
30
250*
250*
250*
125
250*
250*
--- ---
250*
250*
250*
175
250*
250*
--- ---
250*
250*
250*
200
250*
250*
--- ---
250*
250*
250*
225*
250*
250*
--- ---
250*
250*
250*
250*
250*
250*
--- ---
250*
250*
250*
250*
250*
250*
--- ---
250*
250*
250*
250*
250*
250*
--- ---
18000
AC with
Puron
3/8
3/8
24000
AC with
Puron
30000
AC with
Puron
3/8
3/8
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
36000
AC with
Puron
42000
AC with
Puron
48000
AC with
Puron
49000
AC with
Puron
60000
AC with
Puron
61000
AC with
Puron
5/16
3/8
225*
250*
175
250*
250*
200
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
5/16
3/8
3/8
3/8
3/8
250*
250*
3/8
3/8
3/8
3/8
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
3/8
3/8
* Maximum actual length not to exceed 200 ft (61 m)
Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.
--- --- = o u t s i d e a c c e p t a b l e r a n g e
{
3
Download from Www.Somanuals.com. All Manuals Search And Download.
REFRIGERANT CHARGE ADJUSTMENTS
Liquid Line Size
Puron Charge oz/ft
0.60
3/8
(Factory charge for lineset = 9 oz)
5/16
1/4
0.40
0.27
Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter
liquid lines, charge adjustments are required per the chart above.
Charging Formula:
[(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment
Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required?
Formula:
(.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz.
Net result is to remove 4.95 oz of refrigerant from the system
Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment?
Formula:
(.40 oz/ft. x 45ft) – (9 oz.) = 9 oz.
Net result is to add 9 oz of refrigerant to the system
LONG LINE APPLICATIONS
An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable
refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line
depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.
For Air Conditioner systems, the chart below shows when an application is considered Long Line.
AC WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m)
Beyond these lengths, long line accessories are required
Liquid Line Size
Units On Same Level
Outdoor Below Indoor
Outdoor Above Indoor
No accessories needed within allowed
lengths
No accessories needed within allowed
lengths
1/4
175 (53.3)
5/16
3/8
120 (36.6)
80 (24.4)
50 (15.2)
35 (10.7)
120 (36.6)
80 (24.4)
Note: See Long Line Guideline for details
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for AC systems with Puron refrigerant:
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Maximum
Liquid Line
Diameters
(In. OD)
Unit
Nominal
Size (Btuh)
Vapor Line
Diameters
(In. OD)
26---50
(7.9---15.2)
51---80
81---100
101---125
126---150
151---175
176---200
201---225
226---250
(15.5---24.4) (24.7---30.5) (30.8---38.1) (38.4---45.7) (46.0---53.3) (53.6---61.0) (61.3---68.6) (68.9---76.2)
18000
1 Stage
AC with
Puron
1/2
5/8
3/4
5/8
3/4
7/8
5/8
3/4
7/8
5/8
3/4
7/8
3/4
7/8
1 1/8
3/4
1
0
0
0
0
0
1
0
0
1
0
0
0
0
0
0
2
1
0
1
0
0
2
0
0
2
1
0
1
0
0
1
3
1
0
2
1
0
3
1
0
4
1
0
2
1
0
2
5
1
0
2
1
0
3
1
0
5
2
1
2
1
0
3
6
2
1
3
1
0
4
1
1
6
2
1
3
1
0
4
7
2
1
3
1
1
5
2
1
8
3
1
4
2
0
5
8
2
1
4
1
1
6
2
1
9
3
1
4
2
0
5
9
3
1
5
2
1
7
2
1
10
4
2
5
2
0
6
11
3
3/8
3/8
3/8
3/8
3/8
1
24000
1 Stage
AC with
Puron
5
2
1
30000
1 Stage
AC with
Puron
8
3
1
36000
1 Stage
AC with
Puron
12
4
2
42000
1 Stage
AC with
Puron
48000,
49000
6
3
0
7
7/8
1 1/8
3/4
0
0
1
0
0
0
0
2
1
0
1
0
4
2
0
1
0
5
2
1
2
0
6
3
1
2
0
7
4
1
2
0
9
4
1
3
1
3
1
1 Stage
AC with
Puron
60000,
61000
1 Stage
AC with
Puron
3/8
3/8
10
5
11
5
7/8
1 1/8
1
1
Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY THERMOSTATS
PART NUMBER
T 2 --- PAC 01
PROGRAM
5 --- 2 D ay
NP
GAS
ELECTRIC
HEAT
COOL
1
1
1
1
1
1
√
√
√
√
√
√
T 2 --- NAC 01
T2SNAC01
NP
THERMOSTAT ACCESSORIES
PART NUMBER
BRIEF DESCRIPTION
THERMOSTATS USED WITH
Thermostat Conversion Kit (4 to 5 wire) --- 10
pack
TSTATXXCNV10
All Bryantr branded thermostats
T X --- L BP01
T X --- MBP01
Large Decorative Backplate
Medium Decorative Backplate
T 6 --- Pxx, T 6 --- Nxx, an d T 2 --- Pxx
T 2 --- Nxx an d T 1 --- Pxx
ACCESSORIES
Unit Sizes --- Series
KIT NUMBER
DESCRIPTION
018---B
024---A
030---A
036---A
042---A
048---B
049---A
060---A
061---A
KAAFT0101AAA
KAATD0101TDR
KSALA0301410
KSALA0601AAA{
HC32GE234
FREEZE THERMOSTAT
TIME DELAY RELAY
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
LOW AMBIENT PSW
MOTORMASTER 230V
MOTOR FAN BALL BEARING
MOTOR FAN BALL BEARING
MOTOR FAN BALL BEARING
MOTOR FAN BALL BEARING
MOTOR FAN BALL BEARING
HARD START (CAP / RELAY)
CYCLE PROTECTOR
SUPPORT FEET
HC34GE240
X
X
HC32GE229
X
HC38GE228
X
HC40GE228
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KSAHS1701AAA
KSACY0101AAA
KSASF0101AAA
KAACS0201PTC
KAALS0201LLS
KAAWS0101AAA
KAACH1701AAA
KAACH1601AAA
KSATX0201PUR
KSATX0301PUR
KSATX0401PUR
KSATX0501PUR
KSASH0601COP
KSASH2101COP
KAALP0401PUR
KAAHI0501PUR
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
START ASSIST PTC
LIQUID LINE SOLENOID
WINTER START
CRANKCASE HTR
CRANKCASE HTR
X
X
S
S
S
S
TXV PURON HSO
X
X
X
TXV PURON HSO
X
X
TXV PURON HSO
X
X
TXV PURON HSO
X
X
X
SOUND HOOD
X
X
X
SOUND HOOD
X
X
X
X
X
X
X
X
X
X
X
X
LOW PRESSURE SWITCH
HIGH PRESSURE SWITCH
X
X
X
X
X
X
X
X
X
X
{
Required accessories include ball bearing fan motor, compressor start assist (CAP / Relay), crankcase heater, evaporator freeze stat, hard shut---off TXV.
X = Accessory / S --- Standard
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY USAGE GUIDELINE
REQUIRED FOR LONG
LINE
APPLICATIONS*
(Over 80 ft./24.38 m)
REQUIRED FOR
SEA COAST
APPLICATIONS
REQUIRED FOR LOW---AMBI-
ENT COOLING APPLICATIONS
ACCESSORY
(Below 55°F/12.8_C)
(Within 2 miles/3.22 km)
Ball Bearing Fan Motor
Compressor Start Assist Capacitor and Relay
Crankcase Heater
Yes{
Yes
Yes
Yes
Yes
No
No
Yes
Yes
No
No
No
No
No
Yes
No
Evaporator Freeze Thermostat
H a r d S h u t --- O f f T X V
Yes
No
Liquid Line Solenoid Valve
®
Motor Master Control or
Yes
No
No
L o w --- a m b i e n t P r e s s u r e S w i t c h
Support Feet
Recommended
Yes
No
No
Recommended
No
Winter Start Control
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline
Application Guideline.
{ Required for Low---Ambient Controller (full modulation feature) MotorMasterr Control.
Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
5. Cycle Protector
A fan motor with ball bearings which permits speed reduction
while maintaining bearing lubrication.
The cycle protector is designed to prevent compressor short
cycling. This control provides an approximate 5--minute delay
after power to the compressor has been interrupted for any
reason, including power outage, protector control trip, thermostat
jiggling, or normal cycling.
Usage Guideline:
Required on all units when MotorMasterr is used.
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor
motor at each start up.
6. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation
when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when low ambient kit has been added.
7. Low--Ambient Pressure Switch Kit
Usage Guideline:
Required for reciprocating compressors in the
following applications:
Long line
A long life pressure switch which is mounted to outdoor unit
service valve. It is designed to cycle the outdoor fan motor in
order to maintain head pressure within normal operating limits
(approximately 100 psig to 225 psig). The control will maintain
working head pressure at low--ambient temperatures down to 0_F
(--18_C) when properly installed.
Low ambient cooling
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the
following applications:
Usage Guideline:
Long line
A Low--Ambient Pressure Switch or MotorMasterr
Low--Ambient Controller must be used when cooling operation is
used at outdoor temperatures below 55_F (12.8_C).
Low ambient cooling
Suggested for all compressors in areas with a history of
low voltage problems.
8. MotorMasterr Low--Ambient Controller
3. Compressor Start Assist — PTC Type
A fan--speed control device activated by a temperature sensor,
designed to control condenser fan motor speed in response to the
saturated, condensing temperature during operation in cooling
mode only. For outdoor temperatures down to --20_F (--28.9_C),
it maintains condensing temperature at 100_F ±10_F (37.8_C ±
5.5_C).
Solid state electrical device which gives a ”soft” boost to the
compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles.
Improves compressor lubrication on restart and minimizes the
chance of liquid slugging.
Usage Guideline:
A MotorMasterr Low Ambient Controller or
Low--Ambient Pressure Switch must be used when
cooling operation is used at outdoor temperatures
below 55_F (12.8_C).
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.
Suggested for all commercial applications.
9. Outdoor Air Temperature Sensor
Designed for use with Bryant Thermostats listed in this
publication. This device enables the thermostat to display the
outdoor temperature. This device also
is required to enable special thermostat features such as auxiliary
heat lock out.
Usage Guideline:
Suggested for all Bryant thermostats listed in this
publication.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessory Description and Usage (Listed Alphabetically) (Continued)
10. Sound Hood
13. Time--Delay Relay
Wraparound sound reducing cover for the compressor. Reduces
the sound level by about 2 dBA.
An SPST delay relay which briefly continues operation of indoor
blower motor to provide additional cooling after the compressor
cycles off.
Usage Guideline:
NOTE: Most indoor unit controls include this feature. For those
that do not, use the guideline below.
Suggested when unit is installed closer than 15 ft (4.57 m) to
quiet areas, bedrooms, etc.
Usage Guideline:
Suggested when unit is installed between two houses less
than 10 ft (3.05 m) apart.
For improved efficiency ratings for certain
combinations of indoor and outdoor units. Refer to
AHRI Unitary Directory.
11. Support Feet
Four stick--on plastic feet that raise the unit 4 in. (101.6 mm)
above the mounting pad. This allows sand, dirt, and other debris
to be flushed from the unit base, minimizing corrosion.
14. Winter Start Control
This control is designed to alleviate nuisance opening of the
low--pressure switch by bypassing it for the first 3 minutes of
operation.
Usage Guideline:
Suggested in the following applications:
Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
For improved sound ratings.
12. Thermostatic Expansion Valve (TXV)
A modulating flow--control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Kit includes valve, adapter tubes, and external equalizer tube.
Hard shut off types are available.
NOTE: When using a hard shut off TXV with single phase
reciprocating compressors, a Compressor Start Assist Capacitor
and Relay is required.
Usage Guideline:
Required to achieve AHRI ratings in certain equipment
combinations. Refer to combination ratings.
Hard shut off TXV or LLS required in air conditioner
long line applications.
Required for use on all zoning systems.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL DATA
MAX
LENGTH
ft. (m)}
60° C
MAX
LENGTH
ft. (m)}
75° C
OPER VOLTS*
COMPR
FAN
MIN WIRE
SIZE{
60° C
MIN WIRE
SIZE{
75° C
MAX FUSE**
or CKT BRK
AMPS
UNIT SIZE
V/PH
MCA
MAX
MIN
LRA
RLA FLA
018---B
024---A
030---A
036---A
042---A
048---B
049---A
060---A
061---A
48.0
58.3
9.0 0.50 11.8
13.5 0.75 17.7
12.8 0.75 16.8
14.1 0.50 18.1
17.9 1.20 23.6
19.9 1.20 26.1
21.8 1.20 26.1
21.4 1.20 28.0
25.0 1.20 32.5
14
14
14
12
10
10
10
8
14
14
14
12
10
10
10
10
10
67 (20.4)
46 (14.0)
44 (13.4)
57 (17.4)
85 (25.9)
70 (21.3)
70 (21.3)
91 (27.7)
94 (28.7)
64 (19.5)
43 (13..1)
41 (12.5)
54 (16.5)
81 (24.7)
67 (20.4)
67 (20.4)
56 (17.1)
58 (17.7)
20
25
25
30
40
40
40
40
50
64.0
77.0
112.0
109.0
117.0
135.0
134.0
208/230/1---60
253
197
8
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{
If wire is applied at ambient greater than 30_C, consult table 310---16 of the NEC (NFPA 70). The ampacity of non---metallic---sheathed cable (NM), trade
name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article 334---80. If other than uncoated (no---plated), 60 or 75_C insulation, copper
wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70).
Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%.
}
* * T ime --- D el ay f u se.
FLA --- Fu l l L oad Amps
LRA --- L ocked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE Standards 90.1
A--WEIGHTED SOUND POWER LEVEL (dBA)
U n i t S i z e ---
Voltage, Series
Standard
Rating (dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125
52.5
57.5
55.0
50.5
52.5
57.5
51.5
55.0
56.5
250
59.0
64.0
63.5
59.5
62.0
61.5
62.0
62.5
63.0
500
65.5
69.0
68.0
64.5
66.0
66.0
67.5
67.5
65.5
1000
70.5
71.0
69.5
70.5
73.5
70.5
73.5
70.5
69.0
2000
64.5
69.0
67.0
62.0
68.0
65.5
69.0
65.0
67.0
4000
59.0
64.5
63.5
59.5
62.0
59.5
64.5
61.0
61.5
8000
54.5
60.0
58.5
54.5
55.5
53.5
62.0
53.5
56.0
0018---B
0024---A
0030---A
0036---A
0042---A
0048---B
0049---A
0060---A
0061---A
76
76
76
76
78
78
78
78
78
NOTE: Tested in accordance with AHRI Standard 270---08 (not listed in AHRI).
A--WEIGHTED SOUND POWER LEVEL (dBA) WITH SOUND SHIELD
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
U n i t S i z e ---
Standard
Voltage, Series
Rating (dBA)
125
55.5
58.0
55.5
51.5
53.0
58.5
53.0
56.5
57.0
250
59.0
64.0
63.0
58.5
62.0
61.5
61.5
62.5
63.0
500
65.0
69.0
68.0
62.0
65.5
66.0
67.5
66.5
65.5
1000
68.5
70.5
69.0
65.0
72.0
69.0
72.0
68.0
67.0
2000
63.5
68.5
67.0
61.0
65.0
64.0
68.0
63.0
65.5
4000
58.0
64.5
63.0
58.0
61.0
58.5
61.5
59.5
59.0
8000
52.0
59.5
58.5
52.0
54.0
51.0
59.0
51.5
52.5
0018---B
0024---A
0030---A
0036---A
0042---A
0048---B
0049---A
0060---A
0061---A
74
75
75
74
76
76
76
75
75
NOTE: Tested in accordance with AHRI Standard 270---08 (not listed in AHRI).
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE---VOLTAGE, SERIES
REQUIRED SUBCOOLING _F (_C)
018---B
024---A
030---A
036---A
042---A
048---B
049---A
060---A
061---A
10 (5.6)
10 (5.6)
10 (5.6)
10 (5.6)
9 (5.0)
10 (5.6)
8 (4.4)
9 (5.0)
9 (5.0)
8
Download from Www.Somanuals.com. All Manuals Search And Download.
4 6 0 - 3 - 6 0
2 0 8 / 2 3 0 - 3 - 6 0
2 3 0 - 1 - 6 0
2 0 8 - 2 3 0 - 1 - 6 0
9
Download from Www.Somanuals.com. All Manuals Search And Download.
4 6 0 - 3 - 6 0
2 0 8 / 2 3 0 - 3 - 6 0
2 3 0 - 1 - 6 0
2 0 8 - 2 3 0 - 1 - 6 0
Download from Www.Somanuals.com. A1ll0Manuals Search And Download.
Wall
11
Download from Www.Somanuals.com. All Manuals Search And Download.
TESTED AHRI COMBINATION RATINGS*
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Bryant database at:
Model Number
116BNA018****B
116BNA024****A
116BNA030****A
116BNA036****A
116BNA042****A
116BNA048****B
116BNA049****A
116BNA060****A
116BNA061****A
Indoor Coil Model Number
CNPV*1917A**
CNPV*3117A**
CNPV*3117A**
CNPV*3717A**
CNPV*4324A**
CAP**6025A**
Furnace Model Number
Cooling Capacity
18,000
EER
12.0
12.0
12.0
12.0
12.0
12.0
11.5
12.0
12.0
SEER
14.5
14.5
14.5
14.5
14.5
14.5
14.0
14.5
14.5
23,600
28,600
34,400
41,500
46,000
48,000
56,000
59,500
CAP**6025A**
CNPV*6124A**
CNPV*6124A**
*
AHRI = Air Conditioning, Heating & Refrigeration Institute
EER
SEER
—
—
Energy Efficiency Ratio
Seasonal Energy Efficiency Ratio
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE
computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. A1ll4Manuals Search And Download.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. A1ll6Manuals Search And Download.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
CONDENSER ONLY RATINGS
SST
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
° F (° C)
55 (12.78)
65 (18.33)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
115 (46.11)
125 (51.67)
116BNA018****B
TCG
SDT
KW
15.70
66.60
0.75
14.90
76.20
0.87
14.10
85.80
0.99
13.20
95.30
1.12
12.30
104.80
1.26
11.30
114.30
1.41
10.20
123.70
1.60
9.20
133.10
1.81
30
(---1.11)
TCG
SDT
KW
17.50
67.80
0.75
16.60
77.30
0.87
15.70
86.80
0.99
14.70
96.30
1.12
13.70
105.70
1.26
12.60
115.10
1.42
11.50
124.40
1.60
10.30
133.80
1.81
35
(1.67)
TCG
SDT
KW
19.40
69.00
0.74
18.40
78.50
0.87
17.40
87.90
0.99
16.30
97.30
1.12
15.20
106.60
1.26
14.00
115.90
1.42
12.80
125.20
1.60
11.50
134.50
1.81
40
(4.44)
TCG
SDT
KW
21.50
70.40
0.74
20.30
79.70
0.86
19.20
89.00
0.99
18.00
98.30
1.13
16.70
107.60
1.27
15.50
116.90
1.43
14.10
126.10
1.61
12.80
135.30
1.82
45
(7.22)
TCG
SDT
KW
23.60
71.60
0.73
22.40
80.90
0.86
21.10
90.10
1.00
19.70
99.40
1.13
18.40
108.60
1.28
17.00
117.80
1.44
15.60
127.00
1.62
14.10
136.20
1.82
50
(10.0)
TCG
SDT
KW
25.90
73.00
0.73
24.50
82.10
0.86
23.10
91.30
1.00
21.60
100.50
1.14
20.10
109.70
1.29
18.60
118.80
1.45
17.10
128.00
1.63
15.50
137.10
1.84
55
(12.78)
116BNA024****A
TCG
SDT
KW
20.30
66.10
1.00
19.40
75.80
1.15
18.30
85.30
1.30
17.20
94.90
1.47
16.10
104.40
1.65
14.80
114.00
1.85
13.60
123.40
2.09
12.20
132.80
2.36
30
(---1.11)
TCG
SDT
KW
22.60
67.20
0.99
21.40
76.80
1.14
20.30
86.30
1.30
19.10
95.80
1.47
17.80
105.30
1.65
16.50
114.70
1.86
15.10
124.10
2.09
13.60
133.50
2.36
35
(1.67)
TCG
SDT
KW
24.90
68.40
0.98
23.70
77.90
1.14
22.40
87.30
1.30
21.00
96.70
1.47
19.60
106.10
1.66
18.20
115.50
1.86
16.70
124.80
2.09
15.10
134.10
2.36
40
(4.44)
TCG
SDT
KW
27.40
69.60
0.97
26.00
79.00
1.14
24.60
88.30
1.30
23.10
97.70
1.48
21.60
107.00
1.66
20.10
116.30
1.87
18.40
125.60
2.10
16.70
134.90
2.37
45
(7.22)
TCG
SDT
KW
30.10
70.80
0.96
28.60
80.10
1.13
27.00
89.40
1.30
25.40
98.70
1.48
23.70
107.90
1.67
22.00
117.20
1.88
20.20
126.40
2.11
18.40
135.60
2.37
50
(10.0)
TCG
SDT
KW
33.00
72.10
0.95
31.30
81.30
1.13
29.50
90.50
1.31
27.70
99.70
1.49
25.90
108.90
1.68
24.10
118.10
1.89
22.10
127.30
2.12
20.20
136.40
2.39
55
(12.78)
116BNA030****A
TCG
SDT
KW
24.90
68.10
1.27
23.50
77.50
1.43
22.20
87.00
1.60
20.80
96.40
1.78
19.40
105.80
1.99
17.90
115.10
2.23
16.20
124.40
2.50
14.40
133.60
2.81
30
(---1.11)
TCG
SDT
KW
27.50
69.40
1.28
26.00
78.70
1.44
24.50
88.10
1.61
23.10
97.40
1.79
21.50
106.70
2.00
19.90
116.00
2.24
18.10
125.30
2.51
16.20
134.40
2.82
35
(1.67)
TCG
SDT
KW
30.30
70.70
1.29
28.60
79.90
1.44
27.10
89.20
1.61
25.50
98.50
1.80
23.80
107.70
2.01
22.00
117.00
2.25
20.10
126.20
2.52
18.10
135.30
2.83
40
(4.44)
TCG
SDT
KW
33.30
72.00
1.29
31.50
81.20
1.44
29.80
90.40
1.61
28.00
99.60
1.80
26.20
108.80
2.01
24.30
118.00
2.26
22.30
127.20
2.53
20.10
136.30
2.85
45
(7.22)
TCG
SDT
KW
36.50
73.50
1.29
34.50
82.50
1.44
32.60
91.70
1.61
30.70
100.80
1.80
28.80
110.00
2.02
26.70
119.20
2.26
24.50
128.20
2.54
22.20
137.20
2.86
50
(10.0)
TCG
SDT
KW
39.90
75.00
1.29
37.80
84.00
1.44
35.70
93.00
1.61
33.60
102.10
1.80
31.50
111.20
2.02
29.30
120.30
2.27
26.90
129.30
2.54
24.40
138.20
2.86
55
(12.78)
See notes on page 20
18
Download from Www.Somanuals.com. All Manuals Search And Download.
CONDENSER ONLY RATINGS CONTINUED
SST
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
° F (° C)
55 (12.78)
65 (18.33)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
115 (46.11)
125 (51.67)
116BNA036****A
TCG
SDT
KW
31.50
68.90
1.50
29.90
78.20
1.73
28.30
87.50
1.96
26.60
96.80
2.21
24.80
106.20
2.50
22.90
115.50
2.82
21.00
124.90
3.21
18.90
134.20
3.66
30
(---1.11)
TCG
SDT
KW
34.80
70.10
1.50
33.00
79.30
1.73
31.20
88.60
1.97
29.40
97.90
2.22
27.40
107.20
2.51
25.40
116.50
2.83
23.30
125.80
3.21
21.10
135.00
3.66
35
(1.67)
TCG
SDT
KW
38.30
71.40
1.51
36.40
80.60
1.74
34.40
89.80
1.98
32.40
99.00
2.24
30.30
108.20
2.52
28.10
117.40
2.85
25.80
126.70
3.22
23.40
135.90
3.66
40
(4.44)
TCG
SDT
KW
42.10
72.80
1.52
40.00
81.90
1.75
37.80
91.00
1.99
35.60
100.20
2.25
33.30
109.40
2.54
30.90
118.50
2.86
28.40
127.70
3.24
25.80
136.80
3.67
45
(7.22)
TCG
SDT
KW
46.20
74.40
1.53
43.90
83.30
1.77
41.50
92.40
2.01
39.00
101.50
2.27
36.50
110.50
2.56
33.90
119.60
2.88
31.20
128.70
3.25
28.40
137.70
3.68
50
(10.0)
TCG
SDT
KW
50.50
76.00
1.55
47.90
84.90
1.79
45.30
93.80
2.04
42.70
102.80
2.30
39.90
111.80
2.58
37.10
120.80
2.91
34.20
129.80
3.28
31.10
138.70
3.70
55
(12.78)
116BNA042****A
TCG
SDT
KW
37.90
69.80
1.83
36.20
79.20
2.03
34.30
88.70
2.26
32.30
98.10
2.54
30.10
107.40
2.86
27.90
116.70
3.22
25.50
125.90
3.63
23.00
135.10
4.09
30
(---1.11)
TCG
SDT
KW
41.90
71.20
1.84
40.00
80.60
2.04
37.90
89.90
2.28
35.70
99.20
2.56
33.30
108.40
2.88
30.80
117.70
3.24
28.30
126.80
3.65
25.60
136.00
4.10
35
(1.67)
TCG
SDT
KW
46.10
72.70
1.85
44.00
81.90
2.05
41.70
91.20
2.30
39.20
100.40
2.58
36.70
109.60
2.90
34.00
118.70
3.26
31.20
127.80
3.67
28.30
136.90
4.13
40
(4.44)
TCG
SDT
KW
50.70
74.20
1.86
48.30
83.30
2.07
45.80
92.50
2.32
43.10
101.60
2.60
40.20
110.80
2.92
37.30
119.80
3.29
34.30
128.90
3.70
31.10
137.90
4.15
45
(7.22)
TCG
SDT
KW
55.50
75.80
1.87
52.90
84.80
2.09
50.10
93.90
2.34
47.10
103.00
2.63
44.00
112.00
2.95
40.80
121.00
3.32
37.50
130.00
3.73
34.10
138.90
4.19
50
(10.0)
TCG
SDT
KW
60.70
77.40
1.89
57.70
86.40
2.11
54.60
95.40
2.36
51.30
104.40
2.66
47.90
113.40
2.99
44.40
122.30
3.36
40.80
131.20
3.77
37.10
140.00
4.22
55
(12.78)
116BNA048****B
TCG
SDT
KW
42.80
67.80
2.00
40.60
77.20
2.29
38.30
86.60
2.58
36.00
96.00
2.87
33.60
105.40
3.17
31.10
114.70
3.51
28.50
124.00
3.90
25.80
133.30
4.35
30
(---1.11)
TCG
SDT
KW
47.40
69.00
1.93
44.80
78.30
2.25
42.30
87.70
2.56
39.70
97.00
2.87
37.10
106.30
3.19
34.40
115.60
3.53
31.60
124.80
3.92
28.60
134.10
4.36
35
(1.67)
TCG
SDT
KW
52.30
70.40
1.82
49.50
79.60
2.18
46.60
88.80
2.52
43.80
98.00
2.85
40.90
107.20
3.19
37.90
116.50
3.55
34.90
125.70
3.94
31.60
134.80
4.38
40
(4.44)
TCG
SDT
KW
57.80
71.80
1.68
54.60
80.80
2.07
51.40
90.00
2.45
48.20
99.10
2.81
45.00
108.30
3.17
41.70
117.40
3.55
38.30
126.60
3.95
34.80
135.70
4.40
45
(7.22)
TCG
SDT
KW
63.70
73.20
1.49
60.10
82.20
1.93
56.50
91.30
2.34
52.90
100.30
2.74
49.40
109.40
3.13
45.70
118.50
3.53
42.00
127.50
3.95
38.10
136.50
4.41
50
(10.0)
TCG
SDT
KW
70.10
74.70
1.25
66.00
83.70
1.74
62.00
92.60
2.20
58.00
101.60
2.63
54.10
110.60
3.06
50.00
119.60
3.49
45.90
128.50
3.94
41.60
137.40
4.41
55
(12.78)
See notes on page 20
19
Download from Www.Somanuals.com. All Manuals Search And Download.
CONDENSER ONLY RATINGS CONTINUED
SST
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
° F (° C)
55 (12.78)
65 (18.33)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
115 (46.11)
125 (51.67)
116BNA049****A
TCG
SDT
KW
45.00
70.30
2.04
42.40
79.50
2.41
39.90
88.90
2.75
37.40
98.20
3.08
34.90
107.60
3.44
32.30
116.90
3.84
29.50
126.20
4.32
26.40
135.40
4.89
30
(---1.11)
TCG
SDT
KW
49.80
71.70
1.99
46.80
80.90
2.39
44.00
90.10
2.75
41.20
99.40
3.10
38.50
108.70
3.47
35.60
118.00
3.87
32.60
127.20
4.34
29.30
136.30
4.90
35
(1.67)
TCG
SDT
KW
54.90
73.20
1.93
51.50
82.40
2.36
48.40
91.50
2.75
45.30
100.70
3.12
42.20
109.90
3.50
39.10
119.00
3.91
35.80
128.20
4.38
32.30
137.20
4.92
40
(4.44)
TCG
SDT
KW
60.40
74.80
1.86
56.60
83.90
2.33
53.00
92.90
2.75
49.60
102.00
3.14
46.20
111.10
3.53
42.80
120.20
3.95
39.30
129.20
4.41
35.50
138.10
4.94
45
(7.22)
TCG
SDT
KW
66.20
76.40
1.78
62.00
85.50
2.28
58.00
94.50
2.73
54.20
103.40
3.15
50.50
112.40
3.56
46.70
121.40
3.99
42.90
130.30
4.45
38.70
139.10
4.98
50
(10.0)
TCG
SDT
KW
72.40
78.20
1.68
67.70
87.10
2.23
63.20
96.10
2.71
59.10
104.90
3.16
55.00
113.80
3.59
50.90
122.60
4.02
46.70
131.40
4.49
42.10
140.10
5.01
55
(12.78)
116BNA060****A
TCG
SDT
KW
49.90
70.90
2.31
47.50
80.40
2.60
45.10
89.80
2.90
42.40
99.20
3.24
39.60
108.50
3.61
36.70
117.80
4.05
33.50
127.00
4.56
30.20
136.30
5.17
30
(---1.11)
TCG
SDT
KW
55.30
72.50
2.31
52.60
81.80
2.61
49.80
91.20
2.93
46.90
100.50
3.27
43.90
109.70
3.65
40.70
118.90
4.08
37.30
128.10
4.59
33.80
137.30
5.19
35
(1.67)
TCG
SDT
KW
61.00
74.10
2.31
58.00
83.40
2.63
54.90
92.60
2.95
51.70
101.80
3.29
48.40
111.00
3.68
45.00
120.10
4.12
41.40
129.20
4.63
37.60
138.30
5.22
40
(4.44)
TCG
SDT
KW
67.20
75.80
2.31
63.80
84.90
2.64
60.30
94.10
2.97
56.90
103.20
3.32
53.30
112.30
3.71
49.60
121.40
4.15
45.70
130.40
4.66
41.70
139.40
5.25
45
(7.22)
TCG
SDT
KW
73.70
77.60
2.31
70.00
86.60
2.65
66.20
95.70
2.99
62.40
104.70
3.35
58.50
113.70
3.75
54.50
122.70
4.19
50.40
131.60
4.70
46.10
140.50
5.28
50
(10.0)
TCG
SDT
KW
80.80
79.50
2.31
76.60
88.40
2.66
72.40
97.30
3.02
68.30
106.20
3.39
64.00
115.20
3.79
59.80
124.00
4.24
55.30
132.90
4.74
50.70
141.60
5.32
55
(12.78)
116BNA061****A
TCG
SDT
KW
47.40
70.70
1.95
46.30
80.00
2.35
45.00
89.20
2.79
43.40
98.50
3.30
41.50
107.70
3.90
39.30
116.90
4.61
36.80
126.00
5.45
33.80
135.10
6.46
30
(---1.11)
TCG
SDT
KW
52.30
72.20
1.98
51.10
81.40
2.38
49.60
90.60
2.82
47.90
99.70
3.34
45.90
108.90
3.94
43.40
118.00
4.65
40.70
127.00
5.49
37.40
136.00
6.49
35
(1.67)
TCG
SDT
KW
57.60
73.90
2.01
56.20
82.90
2.41
54.60
92.00
2.86
52.70
101.00
3.38
50.40
110.10
3.99
47.80
119.10
4.70
44.80
128.10
5.54
41.20
137.00
6.53
40
(4.44)
TCG
SDT
KW
63.20
75.60
2.05
61.70
84.50
2.45
59.90
93.50
2.91
57.80
102.50
3.43
55.30
111.40
4.04
52.40
120.40
4.75
49.00
129.20
5.59
45.20
138.10
6.58
45
(7.22)
TCG
SDT
KW
69.20
77.40
2.09
67.50
86.20
2.50
65.50
95.10
2.96
63.20
104.00
3.49
60.40
112.80
4.10
57.20
121.70
4.82
53.50
130.40
5.65
49.40
139.10
6.64
50
(10.0)
TCG
SDT
KW
75.60
79.30
2.14
73.70
88.00
2.56
71.40
96.80
3.03
68.80
105.60
3.56
65.70
114.30
4.17
62.20
123.00
4.89
58.20
131.70
5.72
53.60
140.30
6.70
55
(12.78)
* AHRI listing applies only to systems shown in Combination Ratings table.
KW --- Outdoor Unit Kilowatts Only.
SDT --- Saturated Temperature Leaving Compressor (° F)
SST --- Saturated Temperature Entering Compressor (° F/° C)
TCG --- Gross Cooling Capacity (1000 Btuh)
20
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR--COOLED, SPLIT--SYSTEM AIR CONDITIONER
GUIDE SPECIFICATIONS
GENERAL
System Description
116B
1--1/2 TO 5 NOMINAL TONS
Fans
—
—
Condenser fan will be direct--drive propeller type,
discharging air upward.
Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings. Shafts will be corrosion resistant.
Outdoor--mounted, air--cooled, split--system air conditioner unit
suitable for ground or rooftop installation. Unit consists of a
hermetic compressor, an air--cooled coil, propeller--type
condenser fan, and a control box. Unit will discharge supply air
upward as shown on contract drawings. Unit will be used in a
refrigeration circuit to match up to a packaged fan coil or coil
unit.
—
—
Fan blades will be statically and dynamically balanced.
Condenser fan openings will be equipped with coated
steel wire safety guards.
Quality Assurance
—
—
—
—
Unit will be rated in accordance with the latest edition
of AHRI Standard 210.
Compressor
—
—
Compressor will be hermetically sealed.
Unit will be certified for capacity and efficiency, and
listed in the latest AHRI directory.
Unit construction will comply with latest edition of
ANSI/ ASHRAE and with NEC.
Unit will be constructed in accordance with UL
standards and will carry the UL label of approval. Unit
will have c--UL--us approval.
Compressor will be mounted on rubber vibration
isolators.
Condenser Coil
—
—
Condenser coil will be air cooled.
Coil will be constructed of aluminum fins mechanically
bonded to copper tubes which are then cleaned,
dehydrated, and sealed.
—
Unit cabinet will be capable of withstanding Federal
Test Method Standard No. 141 (Method 6061) 500--hr
salt spray test.
Refrigeration Components
—
Refrigeration circuit components will include
liquid--line shutoff valve with sweat connections,
vapor--line shutoff valve with sweat connections,
system charge of Puronr (R--410A) refrigerant, and
compressor oil.
—
—
Air--cooled condenser coils will be leak tested at 150
psig and pressure tested at 450 psig.
Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is
—
Unit will be equipped with filter drier for Puron
refrigerant.
Operating Characteristics
—
stored and handled per unit manufacturer’s
recommendations.
—
The capacity of the unit will meet or exceed _____
Warranty (for inclusion by specifying engineer)
U.S. and Canada only.
Btuh at a suction temperature of _____ _F/_C. The
power consumption at full load will not exceed _____
kW.
—
PRODUCTS
Equipment
Factory assembled, single piece, air--cooled air conditioner unit.
Contained within the unit enclosure is all factory wiring, piping,
controls, compressor, refrigerant charge Puronr (R--410A), and
special features required prior to field start--up.
—
Combination of the unit and the evaporator or fan coil
unit will have a total net cooling capacity of _____
Btuh or greater at conditions of _____ CFM entering
air temperature at the evaporator at _____ _F/_C wet
bulb and _____ _F/_C dry bulb, and air entering the
unit at _____ _F/_C.
Unit Cabinet
—
The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.
—
Unit cabinet will be constructed of galvanized steel,
bonderized, and coated with a powder coat paint.
Electrical Requirements
—
Nominal unit electrical characteristics will be _____ v,
single phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v
to _____ v.
—
—
Unit electrical power will be single point connection.
Control circuit will be 24v.
Special Features
—
Refer to section of this literature identifying accessories
and descriptions for specific features and available
enhancements.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM DESIGN SUMMARY
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc.
2. Minimum outdoor operating air temperature for cooling mode without low--ambient operation accessory is 55_F (12.8_C).
3. Maximum outdoor operating air temperature is 125_F (51.7_C).
4. For reliable operation, unit should be level in all horizontal planes.
5. For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or 35 ft (10.7 m) vertical differential, consult Residential
Piping and Longline Guideline and Service Manual available from equipment distributor.
6. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing
lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4
mm).
7. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
8. Do not apply capillary tube indoor coils to these units.
9. Factory--supplied filter drier must be installed.
Catalog No: PDS116B---04
Copyright 2012 Bryant Heating & Cooling Systems. S 7310 W. Morris St. S Indianapolis, IN 46231
Edition Date: 09/12
Replaces: PDS116B---03
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
|