INSTALLATION INSTRUCTIONS
HB0072
E64000 SERIES
! INTENDED FOR DOMESTIC COOKING ONLY !
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14.
SV08341 rev. B
Download from Www.Somanuals.com. All Manuals Search And Download.
- E64000 SERIES RANGE HOOD SYSTEM -
INTERNAL BLOWERS
MODEL 441
(10” ROUND
WALL CAP)
MODEL 647
(7” ROUND
WALL CAP)
MODEL 437
(HIGH CAPACITY ROOF CAP)
MODEL 634
OR 644
(ROOF CAP)
MODEL 643
(8” ROUND
WALL CAP)
MODEL 415
7” ROUND
ADJUSTABLE ELBOW
8” ROUND
ADJUSTABLE ELBOW
MODEL 418
(10” ROUND ADJUSTABLE ELBOW)
MODEL 407
(7” ROUND -
2 FT. SECTIONS)
8” ROUND
STANDARD
DUCT
MODEL 421
(10” ROUND VERTICAL
IN-LINE DAMPER
MODEL 639
(3¼” X 10”
WALL CAP)
MODEL 412
TRANSITION
(3¼” X 10” TO 7”)
MODEL 413
TRANSITION
(3¼” X 10” TO 8”)
MODEL 410
(10” ROUND DUCT—2 FT. SECTIONS)
STANDARD
DUCT
(3¼” X 10”)
MODEL 423
(4½” X 18½”
MODEL 424
(4½” X 18½”
MODEL 454
(4½” X 18½”
MODEL 453
MODEL 427
(4½” X 18½”
TO 10” ROUND,
6” HIGH - LATERAL
(4½” X 18½”
TO 10” ROUND -
HORIZ. /LEFT
TO 10” ROUND - TO 10” ROUND - HORIZ. TO 10” ROUND -
VERTICAL
FRONT/REAR
HORIZ. /RIGHT
RECIRCULATION KIT
ANKE60 SERIES
ADAPTER /DAMPER
3¼’’ X 10’’
(SUPPLIED WITH
SINGLE BLOWER HOOD)
ADAPTER 4½” X 18½”
(SUPPLIED WITH
DOUBLE BLOWER HOOD)
E64000 SERIES HOOD
DOUBLE BLOWER (1200 CFM)
48” ONLY
SINGLE BLOWER (600 CFM)
RMP SERIES BACKSPLASH
(STAINLESS STEEL WALL COVERING
WITH WARMING SHELVES.
OPTIONAL.)
HL0097
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
- E64000 SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
MODEL 437
MODEL HLB9 (800 CFM)
OR HLB11 (1100 CFM)
IN-LINE BLOWER
(INCLUDES TWO 8” X 12” TO
10’’ ROUND TRANSITIONS)
(HIGH CAPACITY ROOF CAP)
MODEL 335 (1200 CFM)
OR 336 (1500 CFM)
EXTERIOR BLOWER
MODEL 331H (600 CFM)
OR 332H (900 CFM)
EXTERIOR BLOWER
MODEL 441
(10” ROUND
WALL CAP)
MODEL 643
(8” ROUND
WALL CAP)
MODEL HLB6 (600 CFM)
IN-LINE BLOWER
MODEL 421
(INCLUDES TWO 4½” X 18½” TO
10’’ ROUND TRANSITIONS)
(10” ROUND. VERT.
IN-LINE DAMPER)
RECOMMENDED FOR
USE WITH EXTERIOR
BLOWERS
MODEL 418
10” ROUND
ADJUSTABLE ELBOW
MODEL HLB3 (280 CFM)
IN-LINE BLOWER
(INCLUDES ONE 8” TO 10”
ROUND TRANSITION)
MODEL 410
(10” ROUND DUCT
- 2 FT. SECTIONS)
E64000 SERIES HOOD
332KR IN-LINE AND
EXTERIOR BLOWER ROUGH-IN KIT
(SUPPLIED WITH HOOD)
RMP SERIES BACKSPLASH
(STAINLESS STEEL WALL COVERING
WITH WARMING SHELVES. OPTIONAL)
HL0098
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
1. SELECT BLOWER OPTION AND INSTALLATION TYPE
1.1 NON-DUCTED INSTALLATION
For a non-ducted installation, a non-duct kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness,
we recommend installing this kit with a single (internal) blower hood. The kit fits hoods from 30-inch width up to 48-inch
width. See installation instructions included with the non-duct kit ANKE60 Series.
1.2 DUCTED INSTALLATION
The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blowers
(included with the hood), or hood using external blowers. For hood using external blowers, the Broan Elite E64000 Series
must be installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or
336 only. Other blowers cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 10 and up of
this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10”
round ducts, use a transition (internal blower(s) only). Use 2” duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly
recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion.
Roof cap
Roof cap
10” round duct
3¼” x 10” duct
or 7” or 8” round duct
4½” x 18½” to 10”
transition
3¼” x 10” to 7” or
Wall
cap
3¼” x 10” to 8” transition
(if using round duct)
Wall
cap
Hood
Hood
24” minimum above
cooking surface
24” minimum above
cooking surface
HH0085A
HH0086A
SINGLE INTERNAL BLOWER
TYPICAL DUCTWORK
DOUBLE INTERNAL BLOWERS
TYPICAL DUCTWORK
Exterior blower
Roof cap
10” round duct (except
HLB3, 8” round duct)
In-line blower
10” round duct
Wall
cap
Hood
Hood
24” minimum
above cooking
surface
24” minimum above
cooking surface
HH0092A
HH0087A
MODEL 331H, 332H, 335 OR 336
EXTERIOR BLOWER
TYPICAL DUCTWORK
MODEL HLB3, HLB6, HLB9 OR HLB11
IN-LINE BLOWER TYPICAL DUCTWORK
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
2. PREPARE THE INSTALLATION
CAUTION
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and
gloves.
Make sure that the following items are included:
- Range hood
- Accessories:
• Baffle filters
• Baffle filters handles (located inside the hood)
• 3¼” x 10” adapter/damper (located inside internal single blower hood)
• 4½” x 18½” adapter (screwed inside internal double blower hood)
• In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)
• Bag of parts including:
(1) wire clamp, (9) no. 8 x 1/2”, (2) wire connectors, (8) no. 8-32 x 1/4” screws, (4) no. 8 x 3/8” screws
Parts sold separately:
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)
- Exterior blower assembly 331H, 332H, 335 or 336
- Shielded halogen lights (120 V, 50 W, GU-10) (2 required for 30” and 36” hood width, 3 required for 42” and 48” hood width)
- RMP Series Backsplash (optional)
- ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only)
- Transitions, duct, elbows, dampers, wall or roof cap
Refer to pages 3 and 4 for a complete list of venting options and model numbers.
NOTES: 1. For cabinets with recessed bottom, attach three wood filler strips cut to length (not included), on each side, as
shown below. See illustration and table below for wood filler strips location.
2. For hoods with external or in-line blowers, do not install the transverse wood filler strip.
C
L
HOOD
WIDTHS
30’’
36’’
42’’
CENTER OF WOOD
STRIP LOCATION (A)
133⁄8
163⁄8
193⁄8
223⁄8
”
”
”
”
A
A
10”
48’’
HD0285A
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
2. PREPARE THE INSTALLATION (CONT’D)
DUCTED INSTALLATIONS ONLY
Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen.
See figures below.
NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter
the discharge chosen (vertical or horizontal).
48” INTERNAL DOUBLE BLOWER HOOD
INTERNAL SINGLE BLOWER HOOD
VERTICAL DISCHARGE
CABINET BOTTOM VIEW
CABINET BOTTOM VIEW
HOOD
WIDTHS
DIMENSION C
C
C
L
L
30’’
36’’
42’’
48’’
13”
16”
19”
22”
C
22”
A
A
B
B
5½”
3¾”
2”
2”
10”
10”
5¼”
5¼”
2”
2”
3/4”
7/8”
INTERNAL SINGLE BLOWER HOOD
48” INTERNAL DOUBLE BLOWER HOOD
HORIZONTAL DISCHARGE
HOOD
WIDTHS
DIMENSION C
30’’
36’’
42’’
48’’
13”
16”
19”
22”
C
L
C
L
C
22”
5
¼”
5½”
8
”
B
2”
2”
B
3¾”
2”
2”
A
A
10”
10”
5¼” 5¼”
HOOD WITH IN-LINE OR EXTERIOR BLOWER
CABINET BOTTOM VIEW
3½”
A
B
C
47
8
”
L
VERTICAL DISCHARGE ONLY
10¼”
³
8
”
57
8
”
Ø 10½”
9³8
”
HD0258A
CABINET CENTER LINE
3. INSTALL BACKSPLASH (OPTIONAL)
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order
to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel
or cooktop. (See instructions packed with backsplash.)
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
4. REMOVE FILTERS AND GREASE DRIP RAIL
A. Remove tape on filters.
Remove filters from hood and set
aside.
1
NOTE: It is recommended to start
with the center one(s).
B. Remove tape on grease drip rail (1).
Lift out grease drip rail and set
aside.
A
B
HD0240
5. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)
SINGLE BLOWER HOOD
Remove both screws retaining the adapter/damper (1) from inner top of
the hood.
1
HD0259
DOUBLE BLOWER HOOD
1
First unplug both blower motors (1) before removing 3 screws retaining the
adapter (2) from inner top of the hood.
2
HD0283
Fold the adapter and insert the male part (grey section shown in inset) into
the female part (white section shown in the inset). Then, fold over each
male and female end to finalize assembling the adapter.
HD0284
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY)
Remove the knockout for the chosen opening(s) (horizontal at the back of the hood or vertical on top).
See illustrations below.
VERTICAL DISCHARGE
1
1
2
2
3
3
HORIZONTAL DISCHARGE
NOTE: For ducted installation
only.
HR0021
A
B
Punch out the appropriate electrical knockout hole on top (A) or back (B) of the
hood. Install the wire clamp (included in parts bag).
NOTE: For a non-ducted installation, punch out the back electrical knock-out (B).
HR0024
7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY)
All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal
discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the back panel of the
hood. The procedure below applies for one or two motors.
Unplug the blower.
HE0085
LEFT SIDE MOUNTING
SCREW LOCATION
Using a 5/16” socket, remove all
blower mounting screws from the
inner top of the hood. Keep the
screws for further use.
RIGHT SIDE
MOUNTING SCREW
LOCATION
HD0282
HD0269
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY)
Slide the blower to disengage its flange from the
retaining bracket.
HD0270
Flip the blower and engage its
flange in the back wall retaining
bracket.
RIGHT SIDE
Using a 5/16” socket and the
screws previously removed, secure
the blower to the hood.
MOUNTING
SCREW
LOCATION
LEFT SIDE
MOUNTING
SCREW
LOCATION
HD0271
HD0272
Plug the blower in.
NOTE FOR DUAL BLOWER HOOD
ONLY: Cut off the plastic tie wrap on
left motor cable.
HE0085
8. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)
(INTERNAL BLOWER HOOD ONLY)
Using standard 3/8’’ screws provided,
secure the adapter to the top (or
back) of the hood (2 screws for a
3¼” x 10” adapter/damper and
4 screws for a 4½” x 18½” adapter).
Seal the adapter to the hood using
duct tape. For round ducting, install
an appropriate sized transition and
seal the joints with duct tape.
HJ0013
9. INSTALL ANKE60 RECIRCULATION KIT (NON DUCTED INSTALLATION ONLY)
Refer to the installation sheet included with the recirculation kit for details.
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
10. INSTALL THE HOOD (ALL BLOWERS)
INTERNAL BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of the screws
(smaller part of the key holes [A]) with a pen. Remove the hood and install the (4) 1/2” double thread screws at marked positions,
leaving a 1/8” gap. Remove wiring cover. Insert the cable in the hood through the wire clamp and tighten the wire clamp to secure
the cable. Place the hood under the cabinet and slide it into position. Make sure the adapter (or the transition) enters the ducting.
Secure the hood by tightening the screws completely. Install the last 1/2” double thread screws in the remaining holes [B].
INTERNAL BLOWER HOOD
EXTERIOR OR IN-LINE BLOWER HOOD
A
B
B
A
B
HD0265
EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of
the screws (smaller part of the key holes [A]) with a pen. Remove the hood and install the (4) 1/2” double thread screws at
marked positions, leaving a 1/8” gap. Remove wiring cover on top of the hood, punch-out the electrical knock-out and install the
wire clamp. Insert the cable in the hood through the wire clamp and tighten the wire clamp to secure the cable. Connect wiring
(see instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure the
hood by tightening the screws completely. Install the last 1/2” double thread screws in the remaining holes [B].
11. CONNECT WIRING (ALL BLOWERS)
WARNING
!
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power to be switched on accidentally.
Remove wiring cover from rough-in plate or electrical compartment and set
aside.
A
INTERNAL BLOWERS: Connect cable into wiring box using wire connectors.
Connect BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under GREEN ground screw.
CAUTION
The ORANGE wire (A) is for make-up air device connection only.
If there is no make-up air device, never remove the cap on the
ORANGE wire end.
Reinstall wiring cover.
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.
HE0088
12. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER HOOD)
WARNING
!
Do not plug the two cords together.
A
B
Plug the 3-prong plug cord from rough-in plate to the 3-prong male
connector inside the hood (A) and the 2-prong male connector cord from
rough-in plate to the 2-prong plug inside the hood (B).
HE0078
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
13. INSTALL LIGHT BULBS
WARNING
!
In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed
fixtures.
This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (not included).
1
2
1. Install lamps by placing the bulb leads into their grooves in the socket.
2. Gently push upwards and turn clockwise until secure.
HO0090
WARNING
!
In order to prevent the risk of personal injury, the halogen lamps must be cooled down before removing
them.
To remove lamps, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves.
NOTE: If need be, use a rubber dishwashing glove to add grip when removing the bulb.
14. REINSTALL GREASE DRIP RAIL AND FILTERS
CAUTION
Remove protective plastic film covering filters before installing them.
Reinstall grease drip rail. The illustration beside shows how to reinsert the
grease drip rail into the range hood.
HD0241
1
NOTE: Assemble the metal handles to the filters, using no. 8-32 x 1/4” screws
provided, before reinstalling them in the hood.
It is recommended to install side filters first and finish with center one(s).
1. Insert one end of the filter into the upper channel of the hood.
2
2. Raise the other end toward the inside of hood and insert in the grease
drip rail of the hood.
HD0242
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
15. USE AND CARE
Baffle Filters
The baffle filters should be cleaned frequently. Use a warm detergent solution.Wash more often if your cooking style generates greater
grease—like frying foods or wok cooking.
Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe.
Allow filters to dry completely before reinstalling them in the hood.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate
detergent or as a result of local water conditions—but this will not affect filter performance. This discoloration is not covered by
the warranty.
Grease Drip Rail
The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle
filters, wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail
to dry completely before reinstalling it in the hood.
Blower Cleaning (Internal)
Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water.
Hood Cleaning
Stainless steel cleaning:
Do:
Don’t:
•
Regularly wash with clean cloth or rag soaked with warm
•
Use any steel or stainless steel wool or any other scrapers
water and mild soap or liquid dish detergent.
Always clean in the direction of original polish lines.
Always rinse well with clear water (2 or 3 times) after
cleaning. Wipe dry completely.
You may also use a specialized household stainless steel
cleaner.
to remove stubborn dirt.
Use any harsh or abrasive cleansers.
Allow dirt to accumulate.
Let plaster dust or any other construction residues reach
the hood. During construction/renovation, cover the hood to
make sure no dust sticks to stainless steel surface.
•
•
•
•
•
•
Avoid: When choosing a detergent
• Any cleaners that contain bleach will attack stainless steel.
• Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
• Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should
never be used close to a range.
16. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes
to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
HEAT SENTRY™
This hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower
if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.
WARNING
!
The HEAT SENTRY™ can start the blower even if the hood is turned OFF. In this case, it is impossible to
turn the blower OFF with blower switch. If you must stop the blower, do it from the main electrical panel.
When the temperature level drops to normal, the blower will return to its original setting.
- 13 -
Download from Www.Somanuals.com. All Manuals Search And Download.
16. OPERATION (CONT’D)
4
3
2
1
A
B
HC0034
A) Halogen light knob
B) Blower speed control knob
HC0035
1) Halogen light knob
2) Blower operation indicator
3) ON/OFF blower switch
4) Blower speed control knob
COOKTOP LIGHTING (HALOGEN)
A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity).
BLOWER
The blower is operated using two controls.
Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower indicator (2) turns on and the blower
operates at the previous setting of the speed control (4).
Turn the speed control knob counterclockwise to increase blower speed – clockwise to decrease speed.
17. WARRANTY
WARRANTY
BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY
Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in
materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product or part which
is found to be defective under normal use and service.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to
misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone LLC), faulty installation or
installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or
provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION, SHALL BE THE
PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE LLC SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to
another. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone LLC at one of the addresses or telephone number stated
below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At
the time of requesting warranty service, you must present evidence of the original purchase date.
(For U.S.) Broan-NuTone LLC; 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711
(For Canada) Broan-NuTone Canada; 1140 Tristar Drive, Mississauga, ON L5T 1H9 www.broan.ca 877-896-1119
- 14 -
Download from Www.Somanuals.com. All Manuals Search And Download.
18. WIRING DIAGRAMS
NEON
Broan Elite E64000 Series
Internal blower hoods
BLK
FAN
SWITCH
On 3
SPEED
CONTROL
1
BLK
BRN
BLU
Off 2
ORA
USE ONLY WITH
APPROPRIATE
MAKE-UP AIR SYSTEM
M
M
BLK
ORA
RED
BLK
WHT
ORA
HS
THERMOSTAT
BLU
LINE
NEUTRAL
GROUND
BLK
BLU
WHT
BRN
BLU
WHT
WHT
BLK
BLK
LAMP
SWITCH
RED
BLK
YEL
YEL
L
1-3
YEL
2
WHT
WHT
WHT
COLOR CODE
BLK
BLACK
BLUE
BROWN
ORANGE
RED
WHITE
YELLOW
BLU
BRN
ORA
RED
WHT
YEL
LAMP
LAMP
LAMP
HE0090A
Broan Elite E64000 Series
NEON
BLK
SPEED CONTROL
Exterior or In-Line blower hoods
FAN
SWITCH
On 3
COLOR CODE
1
BLK
BLU
GRN
ORA
WHT
YEL
BLACK
BLUE
GREEN
ORANGE
WHITE
YELLOW
BLK
Off 2
ORA
USE ONLY WITH
APPROPRIATE
MAKE-UP AIR SYSTEM
ORA
HS
THERMOSTAT
BLK
BLU
BLK
BLU
WHT
WHT
BLK
LAMP
SWITCH
YEL
BLK
BLK
YEL
WHT
L
1-3
2
YEL
WHT
WHT
WHT
GRN
WHT
120 V
SUPPLY
LINE
M
BLK
BLK
RETURN
GROUND
WHT
WHT
GRN
LAMP
LAMP
LAMP
REMOTE
BLOWER ASSEMBLY
ROUGH-IN PLATE
HE0091A
WHT
- 15 -
Download from Www.Somanuals.com. All Manuals Search And Download.
19. SERVICE PARTS
Broan Elite E64000 Series
Internal blower hoods
Broan Elite E64000 Series
Exterior or In-Line blower hoods
1
14
2
2
15
15
6
3
3
6
5
5
4
4
14
18
17
7
7
10
9
16
11
12
8
11
12
13
HL0104
13
19
19
HL0103
QTY. (HOOD WIDTH)
30” 36” 42” 48”
QTY. (HOOD WIDTH)
30” 36” 42” 48”
KEY
NO.
PART
NO.
KEY
NO.
DESCRIPTION
PART NO.
DESCRIPTION
ADAPTER/DAMPER 3¼” X 10”
(1-BLOWER HOOD)
ADAPTER 4¼” x 18½” (2-BLOWER HOOD)
1
1
1
1
2 SV06750 BROAN ELITE LOGO
1
2
1
1
1
1
1
2
1
1
1
1
1
3
1
1
1
1
1
3
1
1
1
1
SV13296
SV17797
1
3 SV16569 LAMP SHELL, SOCKET & TRIM ASS’Y
4 SV03435 HEAT SENTRY™ THERMOSTAT
5 SV08338 LIGHT SWITCH
6 SV03501 SPEED CONTROL
7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS)
1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
2
3
4
5
6
7
8
9
SV06750 BROAN ELITE LOGO
SV16569 LAMP SHELL, SOCKET & TRIM ASS’Y
SV03435 HEAT SENTRY™ THERMOSTAT
SV08338 LIGHT SWITCH
SV17640 GREASE RAIL 30”
1
-
-
-
1
-
-
-
1
-
-
-
-
SV03501 SPEED CONTROL
SV17641 GREASE RAIL 36”
11
SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS)
SV08343 REPLACEMENT CHARCOAL FILTERS (PAIR)
SV08344 CHARCOAL FILTER SUPPORTS (PAIR)
INTERNAL MOTOR
SV17642 GREASE RAIL 42”
SV17643 GREASE RAIL 48”
-
-
1
12 SV08337 FILTER SPRING (SET OF 6)
1
2
1
1
-
3
1
2
2
1
-
4
SV17600 BAFFLE FILTER 8.84” X 9.80”
SV17603 BAFFLE FILTER 11.84” X 9.80”
10 SV08097
1
1
1
1
13
(1 OR 2, DEPENDING ON HOOD MODEL)
SV17640 GREASE RAIL 30”
1
-
-
-
1
2
1
1
1
3
1
-
1
-
-
1
-
3
1
1
3
1
-
-
1
-
1
2
2
1
1
4
1
-
-
-
1
1
-
4
1
1
4
1
14 SV08339 BLOWER ROCKER SWITCH
15 SV08093 PILOT LAMP ASS’Y
16 SV08354 ROUGH-IN PLATE 10” ROUND
17 SV13924 FEMALE CONNECTOR
18 SV13923 MALE CONNECTOR
19 SV07680 BAFFLE FILTER HANDLE WITH SCREWS
1
1
1
1
1
3
1
1
1
1
1
1
3
1
1
1
1
1
1
4
1
1
1
1
1
1
4
1
SV17641 GREASE RAIL 36”
SV17642 GREASE RAIL 42”
SV17643 GREASE RAIL 48”
11
12 SV08337 FILTER SPRING (SET OF 6)
SV17600 BAFFLE FILTER 8.84” X 9.80”
SV17603 BAFFLE FILTER 11.84” X 9.80”
14 SV08339 BLOWER ROCKER SWITCH
15 SV08093 PILOT LAMP ASS’Y
19 SV07680 BAFFLE FILTER HANDLE WITH SCREWS
13
SV08341 INSTALLATION GUIDE
*
PARTS BAG ([2] WIRE CONNECTORS,
[9] SCREWS NO. 8 X 1/2”,
SV08353 [1] WIRE CLAMP,
1
1
1
1
*
SV08341 INSTALLATION GUIDE
PARTS BAG ([2] WIRE CONNECTORS,
[9] SCREWS NO. 8 X 1/2”,
SV08353 [1] WIRE CLAMP,
*
[8] MECHANICAL SCREWS NO. 8-32 X 1/4”,
[4] SCREWS NO. 8 X 3/8”)
* NOT SHOWN.
1
1
1
1
*
[8] MECHANICAL SCREWS NO. 8-32 X 1/4”,
[4] SCREWS NO. 8 X 3/8”)
* NOT SHOWN.
- 16 -
Download from Www.Somanuals.com. All Manuals Search And Download.
|