INSTALLATION INSTRUCTIONS  
HB0072  
E64000 SERIES  
! INTENDED FOR DOMESTIC COOKING ONLY !  
READ AND SAVE THESE INSTRUCTIONS  
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.  
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14.  
Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711  
Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119  
REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register  
SV08341 rev. B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- E64000 SERIES RANGE HOOD SYSTEM -  
INTERNAL BLOWERS  
MODEL 441  
(10” ROUND  
WALL CAP)  
MODEL 647  
(7” ROUND  
WALL CAP)  
MODEL 437  
(HIGH CAPACITY ROOF CAP)  
MODEL 634  
OR 644  
(ROOF CAP)  
MODEL 643  
(8” ROUND  
WALL CAP)  
MODEL 415  
7” ROUND  
ADJUSTABLE ELBOW  
8” ROUND  
ADJUSTABLE ELBOW  
MODEL 418  
(10” ROUND ADJUSTABLE ELBOW)  
MODEL 407  
(7” ROUND -  
2 FT. SECTIONS)  
8” ROUND  
STANDARD  
DUCT  
MODEL 421  
(10” ROUND VERTICAL  
IN-LINE DAMPER  
MODEL 639  
(3¼” X 10”  
WALL CAP)  
MODEL 412  
TRANSITION  
(3¼” X 10” TO 7”)  
MODEL 413  
TRANSITION  
(3¼” X 10” TO 8”)  
MODEL 410  
(10” ROUND DUCT—2 FT. SECTIONS)  
STANDARD  
DUCT  
(3¼” X 10”)  
MODEL 423  
(4½” X 18½”  
MODEL 424  
(4½” X 18½”  
MODEL 454  
(4½” X 18½”  
MODEL 453  
MODEL 427  
(4½” X 18½”  
TO 10” ROUND,  
6” HIGH - LATERAL  
(4½” X 18½”  
TO 10” ROUND -  
HORIZ. /LEFT  
TO 10” ROUND - TO 10” ROUND - HORIZ. TO 10” ROUND -  
VERTICAL  
FRONT/REAR  
HORIZ. /RIGHT  
RECIRCULATION KIT  
ANKE60 SERIES  
ADAPTER /DAMPER  
3¼’’ X 10’’  
(SUPPLIED WITH  
SINGLE BLOWER HOOD)  
ADAPTER 4½” X 18½”  
(SUPPLIED WITH  
DOUBLE BLOWER HOOD)  
E64000 SERIES HOOD  
DOUBLE BLOWER (1200 CFM)  
48” ONLY  
SINGLE BLOWER (600 CFM)  
RMP SERIES BACKSPLASH  
(STAINLESS STEEL WALL COVERING  
WITH WARMING SHELVES.  
OPTIONAL.)  
HL0097  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- E64000 SERIES RANGE HOOD SYSTEM -  
IN-LINE AND EXTERIOR BLOWERS  
MODEL 437  
MODEL HLB9 (800 CFM)  
OR HLB11 (1100 CFM)  
IN-LINE BLOWER  
(INCLUDES TWO 8” X 12” TO  
10’’ ROUND TRANSITIONS)  
(HIGH CAPACITY ROOF CAP)  
MODEL 335 (1200 CFM)  
OR 336 (1500 CFM)  
EXTERIOR BLOWER  
MODEL 331H (600 CFM)  
OR 332H (900 CFM)  
EXTERIOR BLOWER  
MODEL 441  
(10” ROUND  
WALL CAP)  
MODEL 643  
(8” ROUND  
WALL CAP)  
MODEL HLB6 (600 CFM)  
IN-LINE BLOWER  
MODEL 421  
(INCLUDES TWO 4½” X 18½” TO  
10’’ ROUND TRANSITIONS)  
(10” ROUND. VERT.  
IN-LINE DAMPER)  
RECOMMENDED FOR  
USE WITH EXTERIOR  
BLOWERS  
MODEL 418  
10” ROUND  
ADJUSTABLE ELBOW  
MODEL HLB3 (280 CFM)  
IN-LINE BLOWER  
(INCLUDES ONE 8” TO 10”  
ROUND TRANSITION)  
MODEL 410  
(10” ROUND DUCT  
- 2 FT. SECTIONS)  
E64000 SERIES HOOD  
332KR IN-LINE AND  
EXTERIOR BLOWER ROUGH-IN KIT  
(SUPPLIED WITH HOOD)  
RMP SERIES BACKSPLASH  
(STAINLESS STEEL WALL COVERING  
WITH WARMING SHELVES. OPTIONAL)  
HL0098  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. SELECT BLOWER OPTION AND INSTALLATION TYPE  
1.1 NON-DUCTED INSTALLATION  
For a non-ducted installation, a non-duct kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness,  
we recommend installing this kit with a single (internal) blower hood. The kit fits hoods from 30-inch width up to 48-inch  
width. See installation instructions included with the non-duct kit ANKE60 Series.  
1.2 DUCTED INSTALLATION  
The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blowers  
(included with the hood), or hood using external blowers. For hood using external blowers, the Broan Elite E64000 Series  
must be installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or  
336 only. Other blowers cannot be substituted. (Blowers sold separately).  
Plan where and how the ductwork will be installed.  
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 10 and up of  
this manual.  
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10”  
round ducts, use a transition (internal blower(s) only). Use 2” duct tape to seal duct joints.  
The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly  
recommended for best capture of cooking impurities.  
Distances over 30” are at the installer and users discretion.  
Roof cap  
Roof cap  
10round duct  
3¼x 10duct  
or 7or 8” round duct  
x 18½to 10”  
transition  
3¼x 10to 7or  
Wall  
cap  
3¼x 10to 8” transition  
(if using round duct)  
Wall  
cap  
Hood  
Hood  
24minimum above  
cooking surface  
24minimum above  
cooking surface  
HH0085A  
HH0086A  
SINGLE INTERNAL BLOWER  
TYPICAL DUCTWORK  
DOUBLE INTERNAL BLOWERS  
TYPICAL DUCTWORK  
Exterior blower  
Roof cap  
10round duct (except  
HLB3, 8” round duct)  
In-line blower  
10round duct  
Wall  
cap  
Hood  
Hood  
24minimum  
above cooking  
surface  
24minimum above  
cooking surface  
HH0092A  
HH0087A  
MODEL 331H, 332H, 335 OR 336  
EXTERIOR BLOWER  
TYPICAL DUCTWORK  
MODEL HLB3, HLB6, HLB9 OR HLB11  
IN-LINE BLOWER TYPICAL DUCTWORK  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. PREPARE THE INSTALLATION  
CAUTION  
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and  
gloves.  
Make sure that the following items are included:  
- Range hood  
- Accessories:  
• Baffle filters  
• Baffle filters handles (located inside the hood)  
• 3¼” x 10” adapter/damper (located inside internal single blower hood)  
• 4½” x 18½” adapter (screwed inside internal double blower hood)  
• In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)  
• Bag of parts including:  
(1) wire clamp, (9) no. 8 x 1/2”, (2) wire connectors, (8) no. 8-32 x 1/4” screws, (4) no. 8 x 3/8” screws  
Parts sold separately:  
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)  
- Exterior blower assembly 331H, 332H, 335 or 336  
- Shielded halogen lights (120 V, 50 W, GU-10) (2 required for 30” and 36” hood width, 3 required for 42” and 48” hood width)  
- RMP Series Backsplash (optional)  
- ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only)  
- Transitions, duct, elbows, dampers, wall or roof cap  
Refer to pages 3 and 4 for a complete list of venting options and model numbers.  
NOTES: 1. For cabinets with recessed bottom, attach three wood filler strips cut to length (not included), on each side, as  
shown below. See illustration and table below for wood filler strips location.  
2. For hoods with external or in-line blowers, do not install the transverse wood filler strip.  
C
L
HOOD  
WIDTHS  
30’’  
36’’  
42’’  
CENTER OF WOOD  
STRIP LOCATION (A)  
1338  
1638  
1938  
2238  
A
A
10  
48’’  
HD0285A  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. PREPARE THE INSTALLATION (CONT’D)  
DUCTED INSTALLATIONS ONLY  
Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen.  
See figures below.  
NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter  
the discharge chosen (vertical or horizontal).  
48INTERNAL DOUBLE BLOWER HOOD  
INTERNAL SINGLE BLOWER HOOD  
VERTICAL DISCHARGE  
CABINET BOTTOM VIEW  
CABINET BOTTOM VIEW  
HOOD  
WIDTHS  
DIMENSION C  
C
C
L
L
30’’  
36’’  
42’’  
48’’  
13”  
16”  
19”  
22”  
C
22”  
A
A
B
B
”  
3¾”  
2”  
2”  
10”  
10”  
”  
”  
2”  
2”  
3/4”  
7/8”  
INTERNAL SINGLE BLOWER HOOD  
48” INTERNAL DOUBLE BLOWER HOOD  
HORIZONTAL DISCHARGE  
HOOD  
WIDTHS  
DIMENSION C  
30’’  
36’’  
42’’  
48’’  
13”  
16”  
19”  
22”  
C
L
C
L
C
22”  
5
¼”  
”  
8
B
2”  
2”  
B
3¾”  
2”  
2”  
A
A
10”  
10”  
”  
HOOD WITH IN-LINE OR EXTERIOR BLOWER  
CABINET BOTTOM VIEW  
3½”  
A
B
C
47  
8
L
VERTICAL DISCHARGE ONLY  
10¼”  
³
8
57  
8
Ø 10½”  
8  
HD0258A  
CABINET CENTER LINE  
3. INSTALL BACKSPLASH (OPTIONAL)  
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order  
to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel  
or cooktop. (See instructions packed with backsplash.)  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. REMOVE FILTERS AND GREASE DRIP RAIL  
A. Remove tape on filters.  
Remove filters from hood and set  
aside.  
1
NOTE: It is recommended to start  
with the center one(s).  
B. Remove tape on grease drip rail (1).  
Lift out grease drip rail and set  
aside.  
A
B
HD0240  
5. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)  
SINGLE BLOWER HOOD  
Remove both screws retaining the adapter/damper (1) from inner top of  
the hood.  
1
HD0259  
DOUBLE BLOWER HOOD  
1
First unplug both blower motors (1) before removing 3 screws retaining the  
adapter (2) from inner top of the hood.  
2
HD0283  
Fold the adapter and insert the male part (grey section shown in inset) into  
the female part (white section shown in the inset). Then, fold over each  
male and female end to finalize assembling the adapter.  
HD0284  
- 8 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY)  
Remove the knockout for the chosen opening(s) (horizontal at the back of the hood or vertical on top).  
See illustrations below.  
VERTICAL DISCHARGE  
1
1
2
2
3
3
HORIZONTAL DISCHARGE  
NOTE: For ducted installation  
only.  
HR0021  
A
B
Punch out the appropriate electrical knockout hole on top (A) or back (B) of the  
hood. Install the wire clamp (included in parts bag).  
NOTE: For a non-ducted installation, punch out the back electrical knock-out (B).  
HR0024  
7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY)  
All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal  
discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the back panel of the  
hood. The procedure below applies for one or two motors.  
Unplug the blower.  
HE0085  
LEFT SIDE MOUNTING  
SCREW LOCATION  
Using a 5/16” socket, remove all  
blower mounting screws from the  
inner top of the hood. Keep the  
screws for further use.  
RIGHT SIDE  
MOUNTING SCREW  
LOCATION  
HD0282  
HD0269  
- 9 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY)  
Slide the blower to disengage its flange from the  
retaining bracket.  
HD0270  
Flip the blower and engage its  
flange in the back wall retaining  
bracket.  
RIGHT SIDE  
Using a 5/16” socket and the  
screws previously removed, secure  
the blower to the hood.  
MOUNTING  
SCREW  
LOCATION  
LEFT SIDE  
MOUNTING  
SCREW  
LOCATION  
HD0271  
HD0272  
Plug the blower in.  
NOTE FOR DUAL BLOWER HOOD  
ONLY: Cut off the plastic tie wrap on  
left motor cable.  
HE0085  
8. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)  
(INTERNAL BLOWER HOOD ONLY)  
Using standard 3/8’’ screws provided,  
secure the adapter to the top (or  
back) of the hood (2 screws for a  
3¼” x 10” adapter/damper and  
4 screws for a 4½” x 18½” adapter).  
Seal the adapter to the hood using  
duct tape. For round ducting, install  
an appropriate sized transition and  
seal the joints with duct tape.  
HJ0013  
9. INSTALL ANKE60 RECIRCULATION KIT (NON DUCTED INSTALLATION ONLY)  
Refer to the installation sheet included with the recirculation kit for details.  
- 10 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. INSTALL THE HOOD (ALL BLOWERS)  
INTERNAL BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of the screws  
(smaller part of the key holes [A]) with a pen. Remove the hood and install the (4) 1/2” double thread screws at marked positions,  
leaving a 1/8” gap. Remove wiring cover. Insert the cable in the hood through the wire clamp and tighten the wire clamp to secure  
the cable. Place the hood under the cabinet and slide it into position. Make sure the adapter (or the transition) enters the ducting.  
Secure the hood by tightening the screws completely. Install the last 1/2” double thread screws in the remaining holes [B].  
INTERNAL BLOWER HOOD  
EXTERIOR OR IN-LINE BLOWER HOOD  
A
B
B
A
B
HD0265  
EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of  
the screws (smaller part of the key holes [A]) with a pen. Remove the hood and install the (4) 1/2” double thread screws at  
marked positions, leaving a 1/8” gap. Remove wiring cover on top of the hood, punch-out the electrical knock-out and install the  
wire clamp. Insert the cable in the hood through the wire clamp and tighten the wire clamp to secure the cable. Connect wiring  
(see instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure the  
hood by tightening the screws completely. Install the last 1/2” double thread screws in the remaining holes [B].  
11. CONNECT WIRING (ALL BLOWERS)  
WARNING  
!
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all  
applicable codes and standards. Before connecting wires, switch power off at service panel and lock  
service disconnecting means to prevent power to be switched on accidentally.  
Remove wiring cover from rough-in plate or electrical compartment and set  
aside.  
A
INTERNAL BLOWERS: Connect cable into wiring box using wire connectors.  
Connect BLACK to BLACK, WHITE to WHITE and  
GREEN or bare wire under GREEN ground screw.  
CAUTION  
The ORANGE wire (A) is for make-up air device connection only.  
If there is no make-up air device, never remove the cap on the  
ORANGE wire end.  
Reinstall wiring cover.  
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.  
HE0088  
12. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER HOOD)  
WARNING  
!
Do not plug the two cords together.  
A
B
Plug the 3-prong plug cord from rough-in plate to the 3-prong male  
connector inside the hood (A) and the 2-prong male connector cord from  
rough-in plate to the 2-prong plug inside the hood (B).  
HE0078  
- 11 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. INSTALL LIGHT BULBS  
WARNING  
!
In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed  
fixtures.  
This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (not included).  
1
2
1. Install lamps by placing the bulb leads into their grooves in the socket.  
2. Gently push upwards and turn clockwise until secure.  
HO0090  
WARNING  
!
In order to prevent the risk of personal injury, the halogen lamps must be cooled down before removing  
them.  
To remove lamps, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves.  
NOTE: If need be, use a rubber dishwashing glove to add grip when removing the bulb.  
14. REINSTALL GREASE DRIP RAIL AND FILTERS  
CAUTION  
Remove protective plastic film covering filters before installing them.  
Reinstall grease drip rail. The illustration beside shows how to reinsert the  
grease drip rail into the range hood.  
HD0241  
1
NOTE: Assemble the metal handles to the filters, using no. 8-32 x 1/4” screws  
provided, before reinstalling them in the hood.  
It is recommended to install side filters first and finish with center one(s).  
1. Insert one end of the filter into the upper channel of the hood.  
2
2. Raise the other end toward the inside of hood and insert in the grease  
drip rail of the hood.  
HD0242  
- 12 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. USE AND CARE  
Baffle Filters  
The baffle filters should be cleaned frequently. Use a warm detergent solution.Wash more often if your cooking style generates greater  
grease—like frying foods or wok cooking.  
Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe.  
Allow filters to dry completely before reinstalling them in the hood.  
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate  
detergent or as a result of local water conditions—but this will not affect filter performance. This discoloration is not covered by  
the warranty.  
Grease Drip Rail  
The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle  
filters, wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail  
to dry completely before reinstalling it in the hood.  
Blower Cleaning (Internal)  
Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water.  
Hood Cleaning  
Stainless steel cleaning:  
Do:  
Don’t:  
Regularly wash with clean cloth or rag soaked with warm  
Use any steel or stainless steel wool or any other scrapers  
water and mild soap or liquid dish detergent.  
Always clean in the direction of original polish lines.  
Always rinse well with clear water (2 or 3 times) after  
cleaning. Wipe dry completely.  
You may also use a specialized household stainless steel  
cleaner.  
to remove stubborn dirt.  
Use any harsh or abrasive cleansers.  
Allow dirt to accumulate.  
Let plaster dust or any other construction residues reach  
the hood. During construction/renovation, cover the hood to  
make sure no dust sticks to stainless steel surface.  
Avoid: When choosing a detergent  
• Any cleaners that contain bleach will attack stainless steel.  
• Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.  
• Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should  
never be used close to a range.  
16. OPERATION  
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes  
to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.  
HEAT SENTRY™  
This hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower  
if it senses excessive heat above the cooking surface.  
1) If blower is OFF - it turns blower ON to HIGH speed.  
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.  
WARNING  
!
The HEAT SENTRY™ can start the blower even if the hood is turned OFF. In this case, it is impossible to  
turn the blower OFF with blower switch. If you must stop the blower, do it from the main electrical panel.  
When the temperature level drops to normal, the blower will return to its original setting.  
- 13 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16. OPERATION (CONT’D)  
4
3
2
1
A
B
HC0034  
A) Halogen light knob  
B) Blower speed control knob  
HC0035  
1) Halogen light knob  
2) Blower operation indicator  
3) ON/OFF blower switch  
4) Blower speed control knob  
COOKTOP LIGHTING (HALOGEN)  
A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity).  
BLOWER  
The blower is operated using two controls.  
Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower indicator (2) turns on and the blower  
operates at the previous setting of the speed control (4).  
Turn the speed control knob counterclockwise to increase blower speed – clockwise to decrease speed.  
17. WARRANTY  
WARRANTY  
BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY  
Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in  
materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product or part which  
is found to be defective under normal use and service.  
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to  
misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone LLC), faulty installation or  
installation contrary to recommended installation instructions.  
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or  
provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.  
BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION, SHALL BE THE  
PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE LLC SHALL NOT BE  
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH  
PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of incidental  
or consequential damages, so the above limitation or exclusion may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to  
another. This warranty supersedes all prior warranties.  
To qualify for warranty service, you must (a) notify Broan-NuTone LLC at one of the addresses or telephone number stated  
below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At  
the time of requesting warranty service, you must present evidence of the original purchase date.  
(For U.S.) Broan-NuTone LLC; 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711  
(For Canada) Broan-NuTone Canada; 1140 Tristar Drive, Mississauga, ON L5T 1H9 www.broan.ca 877-896-1119  
- 14 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18. WIRING DIAGRAMS  
NEON  
Broan Elite E64000 Series  
Internal blower hoods  
BLK  
FAN  
SWITCH  
On 3  
SPEED  
CONTROL  
1
BLK  
BRN  
BLU  
Off 2  
ORA  
USE ONLY WITH  
APPROPRIATE  
MAKE-UP AIR SYSTEM  
M
M
BLK  
ORA  
RED  
BLK  
WHT  
ORA  
HS  
THERMOSTAT  
BLU  
LINE  
NEUTRAL  
GROUND  
BLK  
BLU  
WHT  
BRN  
BLU  
WHT  
WHT  
BLK  
BLK  
LAMP  
SWITCH  
RED  
BLK  
YEL  
YEL  
L
1-3  
YEL  
2
WHT  
WHT  
WHT  
COLOR CODE  
BLK  
BLACK  
BLUE  
BROWN  
ORANGE  
RED  
WHITE  
YELLOW  
BLU  
BRN  
ORA  
RED  
WHT  
YEL  
LAMP  
LAMP  
LAMP  
HE0090A  
Broan Elite E64000 Series  
NEON  
BLK  
SPEED CONTROL  
Exterior or In-Line blower hoods  
FAN  
SWITCH  
On 3  
COLOR CODE  
1
BLK  
BLU  
GRN  
ORA  
WHT  
YEL  
BLACK  
BLUE  
GREEN  
ORANGE  
WHITE  
YELLOW  
BLK  
Off 2  
ORA  
USE ONLY WITH  
APPROPRIATE  
MAKE-UP AIR SYSTEM  
ORA  
HS  
THERMOSTAT  
BLK  
BLU  
BLK  
BLU  
WHT  
WHT  
BLK  
LAMP  
SWITCH  
YEL  
BLK  
BLK  
YEL  
WHT  
L
1-3  
2
YEL  
WHT  
WHT  
WHT  
GRN  
WHT  
120 V  
SUPPLY  
LINE  
M
BLK  
BLK  
RETURN  
GROUND  
WHT  
WHT  
GRN  
LAMP  
LAMP  
LAMP  
REMOTE  
BLOWER ASSEMBLY  
ROUGH-IN PLATE  
HE0091A  
WHT  
- 15 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19. SERVICE PARTS  
Broan Elite E64000 Series  
Internal blower hoods  
Broan Elite E64000 Series  
Exterior or In-Line blower hoods  
1
14  
2
2
15  
15  
6
3
3
6
5
5
4
4
14  
18  
17  
7
7
10  
9
16  
11  
12  
8
11  
12  
13  
HL0104  
13  
19  
19  
HL0103  
QTY. (HOOD WIDTH)  
30” 36” 42” 48”  
QTY. (HOOD WIDTH)  
30” 36” 42” 48”  
KEY  
NO.  
PART  
NO.  
KEY  
NO.  
DESCRIPTION  
PART NO.  
DESCRIPTION  
ADAPTER/DAMPER 3¼” X 10”  
(1-BLOWER HOOD)  
ADAPTER 4¼” x 18½” (2-BLOWER HOOD)  
1
1
1
1
2 SV06750 BROAN ELITE LOGO  
1
2
1
1
1
1
1
2
1
1
1
1
1
3
1
1
1
1
1
3
1
1
1
1
SV13296  
SV17797  
1
3 SV16569 LAMP SHELL, SOCKET & TRIM ASSY  
4 SV03435 HEAT SENTRY™ THERMOSTAT  
5 SV08338 LIGHT SWITCH  
6 SV03501 SPEED CONTROL  
7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS)  
1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
2
3
4
5
6
7
8
9
SV06750 BROAN ELITE LOGO  
SV16569 LAMP SHELL, SOCKET & TRIM ASSY  
SV03435 HEAT SENTRY™ THERMOSTAT  
SV08338 LIGHT SWITCH  
SV17640 GREASE RAIL 30”  
1
-
-
-
1
-
-
-
1
-
-
-
-
SV03501 SPEED CONTROL  
SV17641 GREASE RAIL 36”  
11  
SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS)  
SV08343 REPLACEMENT CHARCOAL FILTERS (PAIR)  
SV08344 CHARCOAL FILTER SUPPORTS (PAIR)  
INTERNAL MOTOR  
SV17642 GREASE RAIL 42”  
SV17643 GREASE RAIL 48”  
-
-
1
12 SV08337 FILTER SPRING (SET OF 6)  
1
2
1
1
-
3
1
2
2
1
-
4
SV17600 BAFFLE FILTER 8.84” X 9.80”  
SV17603 BAFFLE FILTER 11.84” X 9.80”  
10 SV08097  
1
1
1
1
13  
(1 OR 2, DEPENDING ON HOOD MODEL)  
SV17640 GREASE RAIL 30”  
1
-
-
-
1
2
1
1
1
3
1
-
1
-
-
1
-
3
1
1
3
1
-
-
1
-
1
2
2
1
1
4
1
-
-
-
1
1
-
4
1
1
4
1
14 SV08339 BLOWER ROCKER SWITCH  
15 SV08093 PILOT LAMP ASSY  
16 SV08354 ROUGH-IN PLATE 10” ROUND  
17 SV13924 FEMALE CONNECTOR  
18 SV13923 MALE CONNECTOR  
19 SV07680 BAFFLE FILTER HANDLE WITH SCREWS  
1
1
1
1
1
3
1
1
1
1
1
1
3
1
1
1
1
1
1
4
1
1
1
1
1
1
4
1
SV17641 GREASE RAIL 36”  
SV17642 GREASE RAIL 42”  
SV17643 GREASE RAIL 48”  
11  
12 SV08337 FILTER SPRING (SET OF 6)  
SV17600 BAFFLE FILTER 8.84” X 9.80”  
SV17603 BAFFLE FILTER 11.84” X 9.80”  
14 SV08339 BLOWER ROCKER SWITCH  
15 SV08093 PILOT LAMP ASSY  
19 SV07680 BAFFLE FILTER HANDLE WITH SCREWS  
13  
SV08341 INSTALLATION GUIDE  
*
PARTS BAG ([2] WIRE CONNECTORS,  
[9] SCREWS NO. 8 X 1/2”,  
SV08353 [1] WIRE CLAMP,  
1
1
1
1
*
SV08341 INSTALLATION GUIDE  
PARTS BAG ([2] WIRE CONNECTORS,  
[9] SCREWS NO. 8 X 1/2”,  
SV08353 [1] WIRE CLAMP,  
*
[8] MECHANICAL SCREWS NO. 8-32 X 1/4”,  
[4] SCREWS NO. 8 X 3/8”)  
* NOT SHOWN.  
1
1
1
1
*
[8] MECHANICAL SCREWS NO. 8-32 X 1/4”,  
[4] SCREWS NO. 8 X 3/8”)  
* NOT SHOWN.  
- 16 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Car Stereo System F5U203UK User Manual
Best Blower IEX42 User Manual
Black Decker Cordless Drill HD4810 HD5010 HD5010A5 User Manual
Bose Speaker System Speakers User Manual
Boston Acoustics Car Speaker SE45 User Manual
Briggs Stratton Lawn Mower 1687079 User Manual
Brother All in One Printer 885MC User Manual
Camco Stereo Amplifier P Series User Manual
Chamberlain Safety Gate SL920 User Manual
Chief Manufacturing Indoor Furnishings PST 2000 Series User Manual