WARNING: If your appliance is not properly installed a house fire may result. For your safety,
follow the installation directions. Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
·
·
PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater.
Failure to follow these instructions could result in property damage, bodily injury, or even death.
Save these instructions.
PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED
Manufactured by
Breckwell Hearth Products
Eugene, Oregon
Grand Prairie, Texas
ã BRECKWELL HEARTH PRODUCTS
C-L-1001 1/05
Download from Www.Somanuals.com. All Manuals Search And Download.
Do not operate your stove if you smell smoke
coming from it. Turn it off, monitor it, and call your
dealer.
Never try to repair or replace any part of the
stove unless instructions are given in this
manual. All other work should be done by a
trained technician.
Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter fluid, or similar liquids to
start or “freshen up” a fire in this stove. Keep all
such liquids well away from the stove while in use.
Do not throw this manual away. This manual
has important operating and maintenance
instructions that you will need at a later time.
Always follow the instructions in this manual.
Never block free airflow through the open vents of
the stove.
Do not place clothing or other flammable
items on or near the stove.
Keep foreign objects out of the hopper.
The viewing door must be closed and latched
during operation.
The stove will not operate during a power outage.
If an outage does occur, check the stove for
smoke spillage and open a window if any smoke
spills into the room.
Do not operate the stove if the flame
becomes dark and sooty or if the burnpot
overfills with pellets. Turn the stove off,
periodically inspect it, and call your dealer.
Disconnect the power cord before performing any
maintenance or repairs on the stove.
Hot while in operation. Keep children,
clothing, and furniture away. Contact may
cause skin burns. Educate all children of the
danger of a high temperature stove. Young
children should be supervised when they are
in the same room as the stove.
NOTE: Turning the stove “off” does not disconnect
all power from the stove.
If the stove is installed in a room without air
conditioning, or in an area where direct
sunlight can shine on the unit, it is possible
this can cause the temperature of the stove to
rise to operational levels; one of the sensors
could then make the stove start on its own. It
is recommended that the stove be unplugged
when not in use for extended amounts of time
(i.e. during the summer months).
During the start up period; 1) DO NOT open the
viewing door; 2) DO NOT open the damper more
than ¾”; 3) DO NOT add pellets to the burnpot
by hand; 4) DO NOT use the Fuel Feed button
(unless you are priming the auger after running
out of pellets) as a dangerous condition could
result.
Do not unplug the stove if you suspect a
malfunction. Turn the stove off, periodically
inspect it, and call your dealer.
Contact your local building officials to obtain a
permit and information on any installation
restrictions or inspection requirements in your
area. Notify your insurance company of this stove
as well.
The exhaust system must be completely
airtight and properly installed. The pellet vent
joints must be sealed with RTV 500°F
(260°C) silicone sealant, and with UL-181-AP
foil tape.
This unit must be properly installed to prevent the
possibility of a house fire. The instructions must be
strictly adhered to. Do not use makeshift methods
or compromise in the installation.
Allow the stove to cool before carrying out
any maintenance or cleaning. Ashes must be
disposed in a metal container with a tight lid
and placed on a no combustible surface well
away from the home structure.
Your stove requires periodic maintenance and
cleaning. Failure to maintain your stove may lead
to smoke spillage in your home.
This stove is designed and approved for
pelletized wood fuel only. Any other type of
fuel burned in this heater will void the
warranty and safety listing.
This stove must be connected to a standard 120
V., 60 Hz grounded electrical outlet. Do not use an
adapter plug or sever the grounding plug. Do not
route the electrical cord underneath, in front of, or
over the stove.
When installed in a mobile home, the stove
must be bolted to the floor, have outside air,
and NOT BE INSTALLED IN A BEDROOM
(Per H.U.D. requirements). Check with local
building officials.
The exhaust system should be checked, at a
minimum, at least twice a year for any build up of
soot or creosote.
Breckwell Hearth Products grants no
warranty, implied or stated, for the
installation or maintenance of your stove,
and assumes no responsibility of any
consequential damage(s).
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
SAFETY PRECAUTIONS
SPECIFICATIONS
INSTALLATION
Preparation
---------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------
2
3
5
5
5
5
6
6
6
7
9
9
Clearances
Combustion Air Supply
When Outside Air Is Not Used
--------------------------------------------------------------------------
-----------------------------------------------------------------
Venting
-----------------------------------------------------------------------------------------------
P2700 Installation
Electrical Installation
Special Mobil Home Requirements
---------------------------------------------------------------------------------
------------------------------------------------------------------------------
----------------------------------------------------------
OPERATION
--------------------------------------------------------------------------------------------------- 10
Proper Fuel
----------------------------------------------------------------------------------------- 10
Pre-Start-Up Check
Building a Fire
------------------------------------------------------------------------------- 10
------------------------------------------------------------------------------------- 10
The HotRod™ Automatic Fire Starter
-------------------------------------------------------- 10
Panel Controls
Opening Door
Room Air Fan
------------------------------------------------------------------------------------- 10
-------------------------------------------------------------------------------------- 11
-------------------------------------------------------------------------------------- 11
Re-Starting a Warm Stove
If Stove Runs Out Of Pellets
---------------------------------------------------------------------- 11
-------------------------------------------------------------------- 11
Damper Control
------------------------------------------------------------------------------------ 12
Refueling
--------------------------------------------------------------------------------------------- 12
Breckwell Maintenance Tool
Shutdown Procedure
-------------------------------------------------------------------- 12
----------------------------------------------------------------------------- 12
Safety Features
Optional Thermostat
Thermostat Installation
------------------------------------------------------------------------------------ 12
------------------------------------------------------------------------------ 13
-------------------------------------------------------------------------- 13
(Please Read This) Operating Safety Precautions
-------------------------------------- 14
MAINTENANCE
Ash Removal
---------------------------------------------------------------------------------------------- 15
---------------------------------------------------------------------------------------- 15
--------------------------------------------------------------------------------------- 15
---------------------------------------------------------------------------------------- 16
---------------------------------------------------------------------------------------------- 16
---------------------------------------------------------------------------------------------- 16
Ash Disposal
Vacuum Use
Cleaning
Blowers
Chimney Cleaning
-------------------------------------------------------------------------------- 17
Recommended Maintenance Schedule
----------------------------------------------------- 17
Removal & Replacement of Broken Door Glass
------------------------------------------ 17
TROUBLE SHOOTING GUIDE
-------------------------------------------------------------------------- 18
Smoke Smell or Soot Build-Up
---------------------------------------------------------------- 23
ELECTRICAL DIAGRAM
REPLACEMENT PARTS LIST
--------------------------------------------------------------------------------- 24
-------------------------------------------------------------------------- 25
WARRANTY
------------------------------------------------------------------------------------------------------ 26
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Width: 23 1/8”
Height: 30 ½”
Depth: 22 ¼”
Weight: 233 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 50 lbs.
(This can vary widely depending on pellet
size, length, and diameter)
EPA status: exempt
Burn time: 1 lb. to 5.5 lbs. per hour
BTU range: 8,200 to 50,000
Approved installations: mobile home, alcove,
conventional
FIGURE 1
PREPARATION
Factory packaging must be removed, and
some minor assembly work is required prior
to installation. Access to the rear of the
stove is necessary.
NOTE: Normally, your dealer will perform
these functions.
CLEARANCES
The Breckwell P2700 Freestanding has
been tested and listed for installation in
residential, mobile home and alcove
applications.
FLOOR PROTECTION: Freestanding
installations, minimum 24” wide by 29” deep.
The stove must be placed on a continuous
(grouted joints) noncombustible material
such as ceramic tile, cement board, brick,
3/8” millboard or equivalent, or other
approved or listed material suited for floor
protection. NOTE: ceramic tile, or any tile,
requires a continuous sheet beneath to
prevent the possibility of embers falling
through to the combustible floor if cracks or
separation should occur in the finished
surface, this would include floor protection
for Built-in raised hearths. Check local codes
for approved alternatives.
FIGURE 2
Clearances are measured from the sides,
back and face (door opening) or stove body
(refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS
OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES
SPECIFIED BY THE VENT
MANUFACTURER.
FLOOR PROTECTION
(MINIMUM 24” W X 29” D)
FIGURE 3
Download from Www.Somanuals.com. All Manuals Search And Download.
COMBUSTION AIR SUPPLY
For a mobile home installation the stove must be
connected to an outside source of combustion air. A 2”
inside diameter metallic pipe, either flexible or rigid, may
be attached to the inlet at the stove’s rear (refer to figure
4). A rodent guard (minimum ¼” wire mesh)/wind hood
must be used at the terminus (refer to figure 5). All
connections must be secured and airtight by either using
the appropriately sized hose clamp and/or UL-181-AP
foil tape.
For mobile home installations only: 2” inside diameter
pipe may be used for the first 5 feet of combustion air
supply run. From 5 to 10 feet use 2 ¾” inside diameter
pipe. No combustion air supply may exceed 10 feet.
Sources of Outside Combustion Air
a. In fireplaces
·
·
Chimney top.
Ash clean out door.
b. For freestanding installations
·
A hole in floor near stove rear terminating only
in a ventilated crawl space.
·
A hole in the wall behind the stove.
WHEN OUTSIDE AIR IS NOT USED
FIGURE 4
If outside air is not used, it is important that combustion
air is easily available to the air inlet. A closeable outside
air register can be used in tightly insulated homes.
VENTING
The Breckwell P2700 is certified for use with listed
TYPE L-Vent, 3” or 4” diameter in size. The stove was
tested with Simpson Duravent brand. Class “A” chimney
is not required. Refer to the instructions provided by the
vent manufacturer, especially when passing through a
wall, ceiling or roof.
This is a pressurized exhaust system. All vent connector
joints must be sealed with 500°F (260°C) RTV silicone
sealant to ensure consistent performance and avoid
smoke spillage. All horizontal connector joints must be
sealed with UL-181-AP foil tape. We recommend that all
vertical vent connector joints be secured with a minimum
of 3 screws.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
INSTALL VENT AT CLEARANCES SPECIFIED BY
THE VENT MANUFACTURER.
FIGURE 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Equivalent Vent Length (EVL)
The longer the run of pipe in your installation, the more restriction
there is in the system. Therefore, larger diameter pipe should be
used.
·
Use 4” pipe if you have more than 15 feet of equivalent vent
length.
·
·
·
Horizontal runs shall not exceed 10’ of EVL.
Recommended vertical runs to be a minimum of 8’.
To calculate EVL, use the following conversions:
90º elbow or “T”
45º elbow
= 5 equivalent feet
= 3 equivalent feet
Horizontal Pipe Run
Vertical Pipe Run
= 1 equivalent foot per actual foot
= 0.5 equivalent foot per actual foot
NOTE: At altitudes above 3,000 feet, we suggest the use of 4”
diameter vent at an EVL of 7 feet or more.
P2700 INSTALLATION
A. HORIZONTALLY THROUGH WALL (refer to Figure 6)
NOTE: Follow L-Vent chimney manufacturer’s instructions.
1. Position stove, adhering to clearances shown in Figures 1 & 2.
2. Locate position of hole in wall; directly behind stove exhaust
vent (refer to figure 4).
3. Always maintain 3” clearance from combustible materials.
4. Install L-Vent wall thimble per L-Vent manufacturer’s
instructions.
5. Attach enough piping to penetrate and extend at least 6”
beyond exterior walls. An 8-foot vertical pipe run is suggested
where possible to reduce the possibility of smoke spillage in
the event of a loss of negative pressure.
FIGURE 6
6. Attach cap and seal outside wall thimbles with non-hardening
waterproof mastic.
7. Termination should not be located so that hot exhaust gases
can ignite trees, shrubs, or grasses or be a hazard to children.
Exhaust gases can reach temperatures of 500ºF and cause
serious burns if touched.
Locate terminations: a) not less then 3 feet above any
forced air inlet located within 10 feet; b) not less than 4
feet below or horizontally from, or one foot above, any
door, window or gravity air inlet into any building; c)
not less than two feet from an adjacent building and
not less than 7 feet above grade when located
adjacent to
a
public walkway. Mobile home
installations must use a spark arrester.
Download from Www.Somanuals.com. All Manuals Search And Download.
B. VERTICALLY WITH NEW CHIMNEY SYSTEM
(Refer to Figure 7)
NOTE: Follow L-Vent chimney manufacturer’s instructions.
OPTION: To achieve a center vertical installation a 45º elbow and a
clean-out tee can be used to offset the pipe from the exhaust outlet
to the rear center of the stove.
OPTION: Install L-Vent elbow in place of clean-out tee. Locate
stove. Drop plumb bob to center of tee outlet, mark point on ceiling.
Install ceiling support and L-Vent pipe per L-Vent manufacturer’s
instructions.
1. Always maintain 3” clearance from combustible materials.
When passing through additional floors or ceilings, always
install firestop spacer.
2. After lining up for hole in roof, cut either around or square hole
in roof, always 3” larger all the way around pipe. Install upper
edge and sides of flashing under roofing materials, nail to the
roof along upper edge. Do not nail lower edge. Seal nail heads
with non-hardening waterproof mastic.
3. Apply non-hardening, waterproof mastic where the storm collar
will meet the vent and flashing. Slide storm collar down until it
sits on the flashing. Seal and install cap. Mobile home
installations must use a spark arrester.
FIGURE 7
C. VERTICALLY INTO EXISTING CHIMNEY SYSTEM
Adapters are available to adapt from 3” L-Vent to 6” or 8” Class-A
chimney. (Figure 8a)
As an alternative, 3” or 4” L-Vent can be run inside existing chimney
to termination. (Figure 8b)
This is the preferred method.
Follow guidelines for equivalent vent length.
D. VERTICALLY INTO EXISTING MASONRY FIREPLACE
NOTE: Follow L-Vent chimney manufacturer’s instructions.
1. Have the masonry chimney inspected by a qualified chimney
sweep or installer to determine its structural condition.
2. You will need a pipe length equal to the chimney height from
the hearth. If outside combustion air is to be used, you will
need a pipe length equal to the chimney height plus 18 inches.
FIGURE 8a
3. Install a blanking plate and the chimney pipe, and if used the
outside air pipe, as shown in Figure 9.
4. Attach the L-vent adapter, a section of pipe and clean out tee,
making sure the clean out tee is centered in the chimney flue
area. Use RTV, metallic tape, and a minimum of three self-
taping screws at all joint connections to ensure a tight seal.
5. Position the stove, adhering to the clearances in Figures 1 & 2.
6. Measure and build chimney top plate. Cut out holes for
chimney pipe, and if used the outside air pipe. Install and seal
with non-hardening mastic to prevent water leakage. Install
vent cap.
FIGURE 8b
Download from Www.Somanuals.com. All Manuals Search And Download.
E. INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY
NOTE: Follow L-Vent chimney manufacturer’s instructions.
1. Position the stove, adhering to the clearances in Figures 1 & 2.
Mark the center of the hole where the pipe is to pierce the masonry
chimney.
2. It will be necessary to break out the masonry around the location of
the pipe center mark. Use a 4-inch diameter hole for 3-inch pipe
and 5-inch diameter hole for 4-inch pipe.
3. Measure and build chimney top plate. Cut out holes for chimney
pipe, and if used the outside air pipe.
4. Install the tee on the bottom of the vertical pipe system and lower it
down the chimney until the center branch of the tee is level with
the center of the hole in the masonry, as shown in Figure 10.
5. Install and seal the top plate from step 3 with non-hardening
mastic. Slip the storm collar over the pipe, and while holding the
pipe at the proper elevation, affix the collar with a minimum of
three ¼” stainless steel sheet metal screws. Seal all joints and
seams around the collar.
6. Connect the horizontal pipe by pushing it through the hole in the
masonry and lining it up with the branch in the tee. Push the pipe
into the tee while twisting it to lock it into the tee.
7. If desired, once the horizontal pipe is in place, the space between
the pipe and masonry may be filled with high-temperature grout.
FIGURE 9
8. Install the trim collar. An adjustable pipe length and adapter may
be needed to finish the connection to the stove.
ELECTRICAL INSTALLATION
This stove is provided with a 6-foot grounded electrical cord extending
from the rear of the stove. We recommend connecting to a good quality
surge protector that is plugged into a standard three-prong, 120V, 60 Hz
electrical outlet. Voltage variations can lead to serious performance
problems. The Breckwell electrical system is designed for 120V AC with
no more than 5% variation. Breckwell cannot accept responsibility for
poor performance or damage due to inadequate voltage. If connected to
an older, two-prong outlet, a separate ground wire should be run to a
proper ground (refer this to a qualified technician). Always route the
electrical cord so that it will not come in contact with any hot part of the
stove.
SPECIAL MOBIL HOME REQUIREMENTS
WARNING: DO NOT INSTALL IN A SLEEPING ROOM.
For installation in a mobile home, an outside source of combustion air
must be used
(See “COMBUSTION AIR SUPPLY”).
The P2700 must be grounded to the steel chassis of the home with 8
Ga. copper wire using a serrated or star washer to penetrate paint or
protective coating to ensure grounding.
FIGURE 10
The P2700 must be securely fastened to the floor of the mobile home.
Refer to “VENTING” for proper exhaust configurations.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME
FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.
Download from Www.Somanuals.com. All Manuals Search And Download.
PANEL CONTROLS (See Figure 11)
The blowers and automatic fuel supply are controlled from a panel on the left-hand side of the P2700.
The control panel functions are as follows.
a. ON/OFF SWITCH
·
When pushed the stove will automatically ignite. No other firestarter is necessary. The igniter will
stay on for at least 10 and up to 15 minutes, depending on when Proof of Fire is reached. The fire
should start in about 5 minutes.
·
·
The green light located above the On/Off button (in the On/Off box) will flash during the ignition
start-up period. (See figure 11)
The Heat Level Advance is inoperable during the ignition start period. When the green light
continuously stays on the Heat Level Advance can be adjusted to achieve the desired heat output.
NOTE: If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button
must be held down for 2 seconds.
b. FUEL FEED SWITCH
·
·
When the “Fuel Feed” button is pushed and held down the stove will feed pellets continuously into
the burnpot.
While the stove’s auger system is feeding pellets the green light (in the “Fuel Feed” box) will be on.
(See figure 11)
CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BECAUSE IT COULD
SMOTHER THE FIRE AND LEAD TO A DANGEROUS SITUATION.
c. HIGH FAN SWITCH
·
The room air fan speed varies directly with the feed rate. The “HIGH FAN” switch overrides this
variable speed function. It will set the room air blower speed to high at any feed rate setting.
When the “HIGH FAN” button is pushed the room air fan will switch to its highest setting.
When this button is pushed again the room air fan will return to its original setting based on the
Heat Level Advance setting.
·
·
d. RESET TRIM
FIGURE 11
Different size and quality pellet fuel may require adjustment of the “1” feed setting on the Heat Level
Advance bar graph. This is usually a one-time adjustment based on the fuel you are using. The
“RESET TRIM” button when adjusted will allow for 3 different feed rate settings for the #1 feed setting
only. To adjust simply push the “RESET TRIM” button while the stove is operating at setting “1” and
watch the bar graph.
·
When the “1” & “3” lights are illuminated on the bar graph the low feed rate is at its “lowest” setting.
(Approx. 0.9 pounds per hour)
·
·
When the “1” light is illuminated on the bar graph the low feed rate is at its “normal” setting.
When the “1” & “4” lights are illuminated on the bar graph the low feed rate is at its “highest”
setting.
NOTE: When the stove is set on “1” the “reset trim” values will be shown on the Heat Level Advance
bar graph. For example if the Reset Trim is set to its lowest setting every time the stove is set to low the
“1” and “3” lights will be illuminated on the bar graph.
e. HEAT LEVEL ADVANCE
·
This button when pushed will set the pellet feed rate, hence the heat output of your stove. The
levels of heat output will incrementally change on the bar graph starting from level “1” to “5”.
NOTE: When dropping 3 or more heat level settings (4 to 1, or 5 to 2 or 1) push the ‘High Fan’ button
and allow the room air fan to run at that setting for at least 5 minutes to prevent the stove from tripping
the high temp thermodisk. If the high temp thermodisk does trip see “SAFETY FEATURES”.
CAUTION: THE “5” SETTING IS DESIGNED FOR TEMPORARY USE ONLY. IF USED FOR
EXTENDED PERIODS, IT CAN SHORTEN THE LIFE EXPECTANCY OF THE UNITS COMPONENTS.
AVOID USE AT THIS SETTING FOR MORE THAN ONE OR TWO HOURS AT A TIME.
Download from Www.Somanuals.com. All Manuals Search And Download.
PROPER FUEL
THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory-approved pellets are those ¼” or 5/16” in
diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed. Burning wood
in forms other than pellets is not permitted. It will violate the building codes for which the stove has been approved and will void all
warranties. The design incorporates automatic feed of the pellet fuel into the fire at a carefully prescribed rate. Any additional fuel introduced
by hand will not increase heat output but may seriously impair the stoves performance by generating considerable smoke. Do not burn wet
pellets. The stove’s performance depends heavily on the quality of your pellet fuel. Avoid pellet brands that display these characteristics:
a. Excess Fines – “Fines” is a term describing crushed pellets or loose material that looks like sawdust or sand. Pellets can be screened
before being placed in hopper to remove most fines.
b. Binders – Some pellets are produced with materials to hold the together, or “bind” them.
c. High ash content – Poor quality pellets will often create smoke and dirty glass. They will create a need for more frequent
maintenance. You will have to empty the burnpot plus vacuum the entire system more often. Poor quality pellets could damage the
auger. Breckwell cannot accept responsibility for damage due to poor quality pellets. Your dealer can recommend a good quality pellet
dealer in your area.
PRE-START-UP CHECK
Remove optional imitation log set if in use. Remove burnpot, making sure it is clean and none of the air holes are plugged. Clean the firebox,
and then reinstall burnpot. Clean door glass if necessary (a dry cloth or paper towel is usually sufficient). Never use abrasive cleaners on the
glass or door. Check fuel in the hopper, and refill if necessary.
NOTE: The P2700 Hopper can hold up to 50 lbs. of pellets.
BUILDING A FIRE
Never use a grate or other means of supporting the fuel. Use only the Breckwell approved burnpot.
During the start up period:
1) DO NOT open the viewing door.
2) DO NOT open the damper more than ¾”.
3) DO NOT add pellets to the burnpot by hand.
4) DO NOT use the Fuel Feed button (unless you are priming the auger after running out of pellets).
A dangerous condition could result.
NOTE: During the first few fires, your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal.
Maintaining smaller fires will minimize this. Avoid placing items on stovetop during this period because paint could be affected.
THE HOTROD AUTOMATIC FIRESTARTER
a. Fill hopper and clean burnpot.
b. Press “On/Off” button. Make sure light is on.
c. Adjust damper to ½” to ¾” open (pushed in is closed). This will vary depending on your installation and elevation. Once fire is
established adjust for desired flame increasing the amount the damper is open as the heat setting is increased.
(See “DAMPER CONTROL”)
d. Adjust feed rate to desired setting by pressing “Heat Level Advance” button.
If fire doesn’t start in 15 minutes, press “On/Off”, wait a few minutes, clear the burnpot, and start procedure again.
DAMPER CONTROL
The damper control rod on the stove’s lower left side adjusts the combustion air. This control is necessary due to the varied burn
characteristics of individual installations, different pellet brands and pellet feed rates. It allows you to improve the efficiency of your stove.
Providing correct combustion air will reduce the frequency of cleaning your glass door and prevent the rapid buildup of creosote inside your
stove and chimney.
You should adjust the damper based on the fire’s appearance. A low, reddish, dirty fire can be improved by pulling the damper out slightly. A
“blow torch” fire can be improved by pushing the damper in a bit.
As a general rule, on lower feed rate settings, the damper should be in farther. On higher feed rates, the damper should be more open.
Through trial and error, you will find the best setting. Consult your dealer if you need help.
NOTE: On “1”, damper should be out approximately ½” to ¾”. If damper is out too far, it can cause the fire to go out.
OPENING DOOR
If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down. If the stove shuts down
push the “On/Off” button to re-start your stove.
ROOM AIR FAN
When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This usually takes about 10 minutes
from start-up.
Download from Www.Somanuals.com. All Manuals Search And Download.
RE-STARTING A WARM STOVE
If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.
IF STOVE RUNS OUT OF PELLETS
The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes.
After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes.
After the 10 minutes the “3” light on the bar graph will flash and the “On/Off” light will go off.
To restart, refill hopper and press “Fuel Feed” button until pellets begin to fall into burnpot. Press “On/Off” button.
REFUELING
We recommend that you not let the hopper drop below ¼ full.
KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER.
BRECKWELL MAINTENANCE TOOL
A tool has been provided to help with the following functions:
FIGURE 12
a. Stirring pellets in hopper – unlike liquids in a tank, pellets do not drain evenly into the auger. Bridging across the opening can occur.
Pellets can hang up on the sides of the hopper. Occasionally “stirring” the hopper can help.
NOTE: To help prevent bridging of pellets, common wax paper can be rubbed on the sidewalls and bottom of the hopper.
b. Scrape ashes from burnpot.
SHUTDOWN PROCEDURE
Turning your Breckwell stove off is a matter of pressing the “On/Off” control panel switch. The red light will go out. The blowers will continue
to operate until internal firebox temperatures have fallen to a preset level.
SAFETY FEATURES
a. Your stove is equipped with a high temperature thermodisc. This safety switch has two functions.
1. To recognize an overheat situation in the stove and shut down the fuel feed or auger system.
2. In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut down the auger, preventing
the stove from overheating.
NOTE: On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting your stove. On other
units the thermodisk has no reset button and will reset itself once the stove has cooled. The manufacturer recommends that you call your
dealer if this occurs as this may indicate a more serious problem. A service call may be required.
b. If the combustion blower fails, an air pressure switch will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds during operation will cause enough pressure change to activate the air switch,
shutting the fuel feed off. Close the door and press “On/Off” button to continue operation of your stove.
Download from Www.Somanuals.com. All Manuals Search And Download.
OPTIONAL THERMOSTAT
A thermostat may help you maintain a constant house temperature
automatically. A millivolt thermostat is required. A fixed wall mount or
Breckwell’s hand held model can be used. The control panel can be
set up two ways to operate your stove in thermostat mode.
THERMOSTAT INSTALLATION
·
·
·
·
A MILLIVOLT THERMOSTAT IS REQUIRED.
Unplug stove from power outlet.
Remove control board from stove.
The two thermostat wires connect to the terminal block on the
lower left side of the back of the control board.
(See figure 21)
·
Insert the wires in the terminal side and tighten the two screws.
MODES
TO SWITCH BETWEEN ANY OF THE THREE MODES THE STOVE
MUST BE SHUT OFF, THE NEW MODE SELECTED, AND THE
STOVE RESTARTED.
MANUAL MODE
·
In this mode the stove will operate only from the control panel as
detailed in the “OPERATION” section of this owner’s manual.
HIGH/LOW THERMOSTAT MODE
·
When engaged in this mode the stove will automatically switch
between two settings. When warm enough, it will switch to the
#1 or low setting. The room air blower will also slow to its lowest
speed.
·
The Heat Level Advance setting on the bar graph will stay
where it was initially set. When the house cools below the
thermostat setting, the stove will switch to the feed rate of the
heat level advance setting.
ON/OFF THERMOSTAT MODE
·
In this mode when the home is warm enough the stove will shut
off. The fans will continue to run until the stove cools.
·
When the home cools below the thermostat setting, the stove
will automatically restart and run at the last feed rate setting.
NOTE: When in “high/low” or “on/off” thermostat mode –
Do not operate the stove higher than the #3 setting.
·
Set damper control rod approximately ½” to ¾” out. This will vary
depending on elevation and weather conditions. Observe stoves
operation and adjust damper as necessary.
FIGURE 14
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING SAFETY PRECAUTIONS
PLEASE READ THIS!
a. Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skin burns.
b. If you notice a smoldering fire (burnpot full but no visible flame) AND a heavy smoke buildup in firebox,
immediately TURN OFF the stove, but DO NOT unplug it. Do not open the door, change the damper
setting or tamper with any controls on the stove. Wait until firebox clears, and blowers shut down, do as
instructed in “PRE-START-UP CHECK” and “BUILDING A FIRE”, then attempt to restart the fire. If the
problem persists contact your dealer.
c. WARNING: DO NOT ADD PELLETS TO THE BURNPOT BY HAND AT ANY TIME, A DANGEROUS
CONDITION COULD RESULT.
d. WARNING: DURING THE START UP CYCLE; 1) DO NOT OPEN THE VIEWING DOOR; 2) DO NOT
OPEN THE DAMPER MORE THAN ¾”; 3) DO NOT USE THE FUEL FEED BUTTON (UNLESS PRIMING
THE AUGER AFTER RUNNING OUT OF PELLETS). A DANGEROUS CONDITION COULD RESULT.
e. Pellets should be stored in a dry place. The pellets should not be stored within 12” of the stove.
f. DO NOT STORE OR USE FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE, IN THE VICINITY OF
YOUR BRECKWELL STOVE. NEVER USE A GAS OR PROPANE TORCH, GASOLINE, GASOLINE-
TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID OR SIMILAR FLUIDS TO START
OR “FRESHEN UP” A FIRE IN THIS HEATER.
g. WARNING: DO NOT OVERFIRE THIS STOVE. This may cause serious damage to your stove and void
your warranty. It also may create a fire hazard in your home. IF ANY EXTERNAL PART OF THE UNIT
BEGINS TO GLOW, YOU ARE OVERFIRING. Immediately press the “POWER” switch on the control
panel.
h. KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES, SUCH AS FURNITURE, DRAPES,
TOYS, ETC. AT LEAST THREE FEET FROM THE OPERATING STOVE.
i. Maintain proper ventilation. It is important that adequate oxygen be supplied to the fire for the combustion
process. Modern houses are often so well insulated that it may become necessary to open a window
slightly or install an outside air vent to provide sufficient combustion air.
j. Since heating with a solid fuel is potentially hazardous, even with a well made and thoroughly tested stove,
it would be wise to install strategically placed smoke detectors and have a fire extinguisher in a convenient
location, near an exit.
k. Do not open stove door when operating unless necessary. This will create a dirty, inefficient burn and could
allow smoke spillage or sparks to escape.
l. Do not permit operation by young children or those unfamiliar with stove’s operation.
m. Do not service or clean this appliance without disconnecting the power cord.
n. Do not abuse the door glass by striking, slamming or similar trauma. Do not operate the stove with the glass
removed, cracked or broken.
o. If the stove is installed in a room without air conditioning, or in an area where direct sunlight can shine on
the unit, it is possible this can cause the temperature of the stove to rise to operational levels; one of the
sensors could then make the stove start on its own. It is recommended that the stove be unplugged when
not in use for extended amounts of time (i.e. during the summer months).
Download from Www.Somanuals.com. All Manuals Search And Download.
FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED
CAN RESULT IN POOR PERFORMANCE AND SAFETY
HAZARDS. NEVER CLEAN WHEN HOT.
NOTE: Inspect burn pot periodically to see that holes have not
become plugged, if so, clean thoroughly.
ASH REMOVAL
Ashes should be placed in a metal container with a tight-fitting lid.
The closed container or ashes should be placed on a
noncombustible surface or on the ground, well away from all
combustible materials pending final disposal. If ashes are disposed
of by soil burial or otherwise locally dispersed, they should be
retained in the closed container until all cinders have thoroughly
cooled.
ASH DISPOSAL
The P2700 has an ash bin located below the firebox. To remove
ashes:
FIGURE 14
a. Make sure fire is out and firebox is cool.
b. Clean heat exchanger tubes (see “CLEANING” and Figure 14).
c. Remove optional imitation log set, if in use. Remove burn pot
by grasping it and pulling straight out.
d. Empty ashes from burn pot. Scrape burn pot with cleaning tool.
Make sure burnpot holes are not plugged.
e. Scrape ash in firebox into the under-stove bin through the
opening (see Figure 15) or vacuum to remove ashes.
WARNING: Make sure ashes are cool to the touch
before using a vacuum.
See “VACUUM USE”.
f.
Periodically remove and empty ash bin (see Figure 16) by
unscrewing the two knobs on the front of the pedestal below
the lower cowl. Dispose of ashes properly.
(See “ASH REMOVAL” above)
FIGURE 15
g. Replace ash bin, making sure to tighten the knobs and
maintaining a good seal.
h. Replace burn pot. Make sure it is level and pushed all the way
back in when it is reinstalled. If the collar on the burnpot
attached to the fresh air tube is not pushed back to meet the
firebox wall, the Hot Rod will not work properly.
VACUUM USE
If a vacuum is used to clean your unit, we suggest using a vacuum
designed for ashes.
(We recommend LoveLess Ash Vac, 1-800-568-3949 Ext. #27)
Some regular vacuums and shop vacs leak ash into the room. Your
vacuum or shop vac may have a special filter or bag available to
eliminate this leakage.
FIGURE 16
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING
a. Heat Exchange Tubes – Your Breckwell stove is designed
with a built-in heat exchange tube cleaner. This should be used
every two or three days to remove accumulated ash on the
tubes, which reduces the efficiency of your unit. Insert the
handle end (with hole) of the cleaning tool onto the cleaning
rod (refer to figure 14). The cleaner rod is located in the grill
above the stove door. Move the cleaner rod back and forth
several times to clean the heat exchanger tubes. When
finished be sure to leave tube cleaner at the rear of the stove.
b. Interior Chambers – Three ash doors in the firebox in the
P2700 can be removed for periodic cleaning (refer to figure
17). These doors allow access to the chamber surrounding the
firebox.
Periodically, you must vacuum ashes from this chamber. In
some cases you will need to remove creosote, which can
accumulate rapidly under certain conditions. A small wire brush
can be used. It is important to remove this creosote because it
is highly combustible. INSPECT BEHIND THESE CLEANING
PLATES AT LEAST ONCE PER TON OF PELLETS BURNED
UNTIL YOU ARE FAMILIAR WITH HOW ASHES AND
CREOSOTE ACCUMULATE WITH YOUR OPERATING
PRACTICES. Use the small wire brush to also clean the inside
of the chamber walls, above the access doors.
FIGURE 17
BLOWERS
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER
BEFORE SERVICING UNIT.
Cleaning - Over a period of time, ashes or dust may collect on the
blades of both the combustion blower and convection blower.
Periodically the blowers should be vacuumed clean as these
ashes can impede performance. Creosote can also accumulate in
the combustion blower. This needs to be brushed clean. The
convection blower is accessed by opening the stove’s left side
panel. The combustion blower can be accessed by opening the
right side panel. The convection blower is on the left (facing
stove), and the combustion blower is on the right.
NOTE: When cleaning, be careful not to dislodge balancing clip on
convection blower or to bend fan blades. Some stove owners lightly
spray an anti-creosote chemical on the fire to help reduce creosote
formation within the stove.
FIGURE 18
FIGURE 19
Download from Www.Somanuals.com. All Manuals Search And Download.
CHIMNEY CLEANING
a. Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue or a newly started fire or from a slow-
burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire,
which may damage the chimney or even destroy the house. Despite their high efficiency, pellet stoves can accumulate creosote under
certain conditions.
b. Fly Ash – This accumulates in the horizontal portion of an exhaust run. Though noncombustible, it may impede the normal exhaust
flow. It should therefore be periodically removed.
c. Inspection and Removal – The chimney connector and chimney should be inspected annually or per ton to determine if a creosote or
fly ash build-up has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire. Inspect the
system at the stove connection and at the chimney top. Cooler surfaces tend to build creosote deposits quicker, so it is important to
check the chimney from the top as well as from the bottom.
The creosote should be removed with a brush specifically designed for the type of chimney in use. A qualified chimney sweep can perform
this service. It is also recommended that before each heating season the entire system be professionally inspected, cleaned and, if
necessary, repaired.
To clean the chimney, detach the vent at the combustion blower transition where it is attached to the blower.
RECOMMENDED MAINTENANCE SCHEDULE
Use this as a guide under average-use conditions.
Daily
Stirred
Wiped
Weekly
Emptied
Cleaned
Brushed
Annually or per Ton
Burn Pot
Glass
Combustion Chamber
Ashes
Emptied
Interior Chambers
Heat Exchange Tubes
Combustion Blower Blades
Convection Blower Impeller
Vent System
Vacuumed
Two passes
Vacuumed / Brushed
Vacuumed / Brushed
Cleaned
Gaskets
Inspected
Hopper (end of season)
Emptied and vacuumed
Gasket around door and door glass should be inspected and repaired or replaced when necessary (see “REPLACEMENT PARTS”).
REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS
While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass from the
doorframe. Dispose of all broken glass properly. Return the damaged door to your Breckwell Dealer for repair or replacement.
Neither the appliance owner nor any other unauthorized person(s) should replace the door glass. An authorized Breckwell dealer must
perform all repairs involving door glass.
Download from Www.Somanuals.com. All Manuals Search And Download.
When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve
simple problems yourself. Problems can be caused by to only five factors: 1) poor fuel; 2) poor operation or maintenance; 3) poor
installation; 4) component failure; 5) factory defect. You can usually solve those problems related to 1 and 2. Your dealer can solve
problems relating to 3, 4 and 5. Refer to figures 17, 18 and 19 to help locate indicated parts.
STOVE SHUTS OFF AND THE # 2 LIGHT FLASHES
Possible Causes:
Possible Remedies: (Unplug stove first when possible)
1. Airflow switch hose or stove attachment pipes for hose are
blocked.
Unhook air hose from the air switch and blow through it. If air flows
freely, the hose and tube are fine. If air will not flow throw the hose,
use a wire coat hanger to clear the blockage.
2. The air inlet, burnpot, interior combustion air chambers,
combustion blower, or exhaust pipe are blocked with ash or
foreign material.
Follow all cleaning procedures in the maintenance section of the
owner’s manual.
3. The firebox is not properly sealed.
Make sure the door is closed and that the gasket is in good shape.
If the ash door has a latch, make sure the ash door is properly
latched and the gasket is sealing good. If the stove has just a small
hole for the ashes to fall through under the burnpot, make sure the
slider plate is in place to seal off the firebox floor.
4. Vent pipe is incorrectly installed.
Check to make sure vent pipe installation meets criteria in owner’s
manual.
5. The airflow switch wire connections are bad.
Check the connectors that attach the gray wires to the air switch.
Check to see if the gray wires are loose at the Molex connector.
6. The gray wires are pulled loose at the Molex connector on the
wiring harness.
7. Combustion blower failure.
With the stove on, check to see if the combustion blower is running.
If it is not, you will need to check for power going to the combustion
blower. It should be a full current. If there is power, the blower is
bad. If there is not, see #8.
8. Control board not sending power to combustion blower.
If there is no current going to the combustion blower, check all wire
connections. If all wires are properly connected, you have a bad
control board.
9. Control board not sending power to air switch.
10. Air switch has failed (very rare).
There should be a 5-volt current (approximately) going to the air
switch after the stove has been on for 30 seconds.
To test the air switch, you will need to disconnect the air hose from
the body of the stove. With the other end still attached to the air
switch, very gently suck on the loose end of the hose (you may want
to remove the hose entirely off the stove and the air switch first and
make sure it is clear). If you hear a click, the air switch is working.
BE CAREFUL TOO MUCH VACUUM CAN DAMAGE THE AIR
SWITCH.
Download from Www.Somanuals.com. All Manuals Search And Download.
STOVE SHUTS OFF AND THE # 3 LIGHT FLASHES
Possible Causes:
Possible Remedies: (Unplug stove first when possible)
1. The hopper is out of pellets.
Refill the hopper.
2. The air damper is too far open for a low feed setting.
3. The burnpot is not pushed completely to the rear of the firebox.
4. The burnpot holes are blocked.
If burning on the low setting, you may need to close the damper all
the way (push the knob in so it touches the side of the stove).
Make sure that the air intake collar on the burnpot is touching the
rear wall of the firebox.
Remove the burnpot and thoroughly clean it.
5. The air inlet, the interior chambers, or exhaust system has a
partial blockage.
Follow all cleaning procedures in the maintenance section of the
owner’s manual.
6. The auger shaft is jammed.
Start by emptying the hopper. Then remove the auger motor by
removing the auger pin. Remove the auger shaft inspection plate in
the hopper so that you can see the auger shaft. Gently lift the auger
shaft straight up so that the end of the auger shaft comes up out of
the bottom auger bushing. Next, remove the two nuts that hold the
top auger biscuit in. Then rotate the bottom end of the auger shaft
up towards you until you can lift the shaft out of the stove. After you
have removed the shaft, inspect it for bent flights, burrs, or broken
welds. Remove any foreign material that might have caused the
jam. Also, check the auger tube for signs of damage such as burrs,
rough spots, or grooves cut into the metal that could have caused a
jam.
7. The auger motor has failed.
Remove the auger motor from the auger shaft and try to run the unit.
If the motor will turn the shaft is jammed on something. If the motor
will not turn, the motor is bad.
8. The Proof of Fire (POF) thermodisk has malfunctioned.
Temporarily bypass the POF thermodisk by disconnecting the two
brown wires and connecting them with a short piece of wire. Then
plug the stove back in. If the stove comes on and works, you need
to replace the POF thermodisk. This is for testing only. DO NOT
LEAVE THE THERMODISC BYPASSED. Your blowers will never
shut off and if the fire went out the auger will continue to feed pellets
until the hopper is empty if you leave the POF thermodisk bypassed.
9. The high limit thermodisk has tripped or is defective.
10. The fuse on the control board has blown.
Wait for the stove to cool for about 30 - 45 minutes. It should now
function normally. If not use the owner’s manual to locate the high
limit thermodisk. To test if the thermodisk is bad, you can bypass it
as described previously for the POF thermodisk.
Remove the control board. If the fuse appears to be bad, replace it
with a 5 Amp 250 Volt fuse. Plug the stove back in and try to run the
unit.
11. The control board is not sending power to the POF thermodisk
or other auger system components.
There should be a 5-volt (approximately) current going to the POF
thermodisk after the stove has been on for 10 minutes.
Download from Www.Somanuals.com. All Manuals Search And Download.
STOVE FEEDS PELLETS, BUT WILL NOT IGNITE
Possible Causes:
Possible Remedies:
1. Air damper open too far for ignition.
Push the air damper in closer to the side of the stove for startup. In
some situations it may be necessary to have the damper completely
closed for ignition to take place. After there is a flame, the damper
can then be adjusted for the desired feed setting.
2. Blockage in igniter tube or inlet for igniter tube.
Find the igniter housing on the backside of the firewall. The air
intake hole is a small hole located on bottom side of the housing.
Make sure it is clear. Also, look from the front of the stove to make
sure there is not any debris around the igniter element inside of the
igniter housing.
3. The burnpot is not pushed completely to the rear of the firebox.
4. Bad igniter element.
Make sure that the air intake collar on the burnpot is touching the
rear wall of the firebox.
Put power directly to the igniter element. Watch the tip of the igniter
from the front of the stove. After about 2 minutes the tip should
glow. If it does not, the element is bad.
5. The control board is not sending power to the igniter.
Check the voltage going to the igniter during startup. It should be a
full current. If the voltage is lower than full current, check the wiring.
If the wiring checks out good, the board is bad.
SMOKE SMELL COMING BACK INTO THE HOME
Possible Causes:
Possible Remedies:
1. There is a leak in the vent pipe system.
Inspect all vent pipe connections. Make sure they are sealed with
RTV silicone that has a temperature rating on 500 degree F or
higher. Also, seal joints with UL-181-AP foil tape. Also, make sure
the square to round adapter piece on the combustion blower has
been properly sealed with the same RTV.
2. The gasket on the combustion blower has gone bad.
Inspect both gaskets on the combustion blower to make sure they
are in good shape.
CONVECTION BLOWER SHUTS OFF AND COMES BACK ON
Possible Causes:
Possible Remedies:
1. The convection blower is overheating and tripping the internal
temperature shutoff.
Clean any dust off of the windings and fan blades. If cleaning the
blower does not help, the blower may be bad.
2. Circuit board malfunction.
Test the current going to the convection blower. If there is power
being sent to the blower when it is shut off, then the control board is
fine. If there is NOT power being sent to the blower when it shuts off
during operation, then you have a bad control board.
Download from Www.Somanuals.com. All Manuals Search And Download.
STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED
Possible Causes:
Possible Remedies:
1. Fuse on control board blew
Remove the control board. If the fuse appears to be bad, replace it
with a 5 Amp 250 Volt fuse. Plug the stove back in and try to run the
unit.
2. High limit switch has tripped or is defective
Wait for the stove to cool for about 30 - 45 minutes. It should now
function normally. If not use the owner’s manual to locate the high
limit thermodisk. To test if the thermodisk is bad, you can bypass it
as described previously for the POF thermodisk.
3. Bad auger motor
4. Auger jam
Remove the auger motor from the auger shaft and try to run the unit.
If the motor will turn, the shaft is jammed on something. If the motor
will not turn, the motor is bad.
Start by emptying the hopper. Then remove the auger motor by
removing the auger pin. Remove the auger shaft inspection plate in
the hopper so that you can see the auger shaft. Gently lift the auger
shaft straight up so that the end of the auger shaft comes up out of
the bottom auger bushing. Next, remove the two nuts that hold the
top auger biscuit in. Then rotate the bottom end of the auger shaft
up towards you until you can lift the shaft out of the stove. After you
have removed the shaft, inspect it for bent flights, burrs, or broken
welds. Remove any foreign material that might have caused the
jam. Also, check the auger tube for signs of damage such as burrs,
rough spots, or grooves cut into the metal that could have caused a
jam.
5. Loose wire or connector
6. Bad control board
Check all wires and connectors that connector to the auger motor,
high limit switch, and the Molex connector.
If the F2 fuse is good, the wires and connectors check out good, and
the high limit switch did not trip, test for power going to the auger
motor. If there is not a full current going to the auger motor when
the fuel feed light is on, you have a bad control board.
Download from Www.Somanuals.com. All Manuals Search And Download.
·
·
·
GLASS “SOOT’S” UP AT A VERY FAST RATE
FLAME IS LAZY, DARK, AND HAS BLACK TIPS
AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS
Possible Causes:
Possible Remedies:
1. Stove or vent pipe is dirty, which restricts airflow through the
burnpot.
Follow all cleaning procedure in the maintenance section of the
owner’s manual.
2. Vent pipe installed improperly.
Check to make sure the vent pipe has been installed according to
the criteria in the owner’s manual.
3. Air damper is set too far in (closed) for a higher setting.
Pull the damper knob farther out away from the side of the stove and
try to burn the unit again.
4. Burnpot holes are blocked.
5. Air damper is broken.
Remove the burnpot and thoroughly clean it.
Visually inspect the damper assembly. Make sure the damper plate
is attached to the damper rod. When the damper rod is moved the
plate should move with it.
6. Blockage in air intake pipe.
7. Circuit board malfunction.
Visually inspect the air intake pipe that leads into the burnpot for
foreign material.
Time the fuel feed light at each setting (after the stove has
completed the startup cycle). Make sure the times match the auger
timing chart. If the auger motor runs constantly, the board is bad.
8. Combustion blower is not spinning fast enough.
Test the RPM on the blower after the blades have been cleaned.
The RPM should be approximately 3000 RPM.
9. Bad Pellets
The brand of pellets or the batch of pellets that are being used may
be of poor quality. If possible, try a different brand of pellets. You
might also want to try a brand that is made from a different type of
wood (softwood vs. hardwood). Different woods have different
characteristics when being burned.
(Applies to GLASS “SOOT’S” UP AT A VERY FAST RATE Only)
10. The trim setting on the low feed rate is to low
Use the “Reset Trim” button to increase the low feed rate setting. If
the 1 & 4 are on, the stove is currently on the lowest setting. If only
the 1 light is on, the stove is in the default (medium) setting. If the 1
& 5 lights are on, the stove is in the high trim setting for the low feed
rate. If the stove is being burned on one of the two lower settings,
advance to the next trim setting and try burning the stove.
(Applies to GLASS “SOOT’S” UP AT A VERY FAST RATE Only)
Download from Www.Somanuals.com. All Manuals Search And Download.
HIGH LIMIT SWITCH KEEPS TRIPPING
Possible Causes:
Possible Remedies:
1. The convection blower is overheating and tripping the internal
temperature shutoff.
Clean any dust off of the windings and fan blades. If cleaning the
blower does not help, the blower may be bad.
2. The stove is being left on the highest setting for extended
periods of time.
The highest heat level setting is designed for use over short periods
of time. Burning the stove on the highest setting for longer than 1 –
2 hours could lead to potential overheating situations.
3. Fuel other than wood pellets is being burned in the stove.
Breckwell pellet stoves are designed and tested to use wood pellets.
While it is possible to burn a corn mixture (corn mixed in with wood
pellets) in the stove, it is not recommended to burn above the
number 3 heat level. Check for signs of fuel other than wood
pellets. If there are signs of corn being used, find out what mixed
was being used and what setting. No other types of fuel have been
approved for Breckwell pellet stoves. If there are signs of other
types of fuel being used, advise the consumer to stop using them
immediately.
4. High limit switch is malfunctioning.
If the other items check out ok, replace the high limit switch.
DIGITAL CIRCUIT BOARD TIMING RATES
Heat Level Setting
P2700
1 & 3
1.4 seconds
2 seconds
2.5 seconds
4 seconds
7 seconds
9 seconds
12 seconds
1
1 & 4
2
3
4
5
Total Cycle Time
14.5 seconds
SMOKE SMELL OR SOOT BUILD-UP
Because it is a wood-burning device, your Breckwell may emit a faint wood-burning odor. If this increases beyond normal, or if you notice an
unusual soot build-up on walls or furniture, check your exhaust system carefully for leaks. All joints should be properly sealed. Also clean
your stove, following instructions in “MAINTENANCE”. If problem persists, contact your dealer.
Download from Www.Somanuals.com. All Manuals Search And Download.
FIGURE 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Contact an Authorized Breckwell Pellet Stove Dealer to obtain any of these parts. Never use
substitute materials. Use of non-approved parts can result in poor performance and safety
hazards.
ITEM
PART #
Air Switch
C-E-201
Air Switch Hose
Auger Motor
C-M-340-T
C-E-017
Breckwell Maintenance Tool
Brick Panel Set, Ceramic – Optional
Burnpot
Ceramic Firelog Set (imitation) - Optional
Circuit Board / Control Panel
Combustion Blower
Convection Blower
A-TOOL-96
A-M-BRICK27
A-S-BURNPOT
A-M-LOG
C-E-401
A-E-027
A-E-033
Door Gasket
C-G-050
Door Glass (center)
Door Glass (side)
Exhaust Adapter 3”
Exhaust Adapter 4”
Hot Rod Igniter
C-D-2700-A
C-D-2700-B
C-M-050
A-4-VA
C-E-IGN
Remote Thermostat – RF – Acumen - Optional
Thermodisk, Proof of Fire
Thermodisk, High Temp
Door Handle (wood)
Damper Knob (wood)
Window Gasket (6’-1”)
AG-RCN
C-E-090-22C
C-E-090-21
C-S-851
C-S-852
C-G-033
Download from Www.Somanuals.com. All Manuals Search And Download.
LIFETIME LIMITED WARRANTY
Breckwell Hearth Products warrants to the original consumer purchaser that the Breckwell stove
in its original installation is free from defects in material and workmanship from the original date
of purchase as follows:
Steel fabricated components, excluding burnpot inserts, are covered for five years. Glass and
burnpot inserts are warranted for one year only for thermal damage. Electrical components,
which include the digital control board, auger motor, combustion and convection blowers,
igniter, and valves, are covered for one year. There is no warranty on gaskets or paint. After
expiration of the warranty period, any components may be purchased at 30% discount off
manufacturers suggested list price plus shipping and handling charges, as long as the original
consumer purchaser owns the product.
This warranty covers defect in materials and workmanship in covered components, provided
this product has been properly installed and operated strictly in accordance with the instructions
in this owner’s manual and any applicable local codes. This warranty does not cover damage or
breakage caused by improper handling, misuse, abuse, overfiring, disassembly, unauthorized
modification or other circumstances beyond Breckwell’s control.
If warranty service is needed during the warranty period, notify the nearest Authorized Breckwell
Dealer. Provide your name, address, phone number, serial number and model number of the
stove, date of purchase, name and address of installer and as much information as possible
about the nature of the problem.
If the dealer must examine the Breckwell stove at the consumer’s residence, a reasonable
service call charge may be incurred and is the responsibility of the consumer. If the unit must
be transported, those charges will be the consumer’s responsibility. Breckwell’s sole
responsibility is to repair or replace the defective part as stated herein. Breckwell will not be
liable for consequential or indirect damages to property or persons resulting from use of this
product. No other express warranty is given and no affirmation of Breckwell or its agents by
work or action shall constitute a warranty.
All disputes relating to this warranty shall be tried before the courts of Oregon. Venue in any
litigation arising hereunder shall be in the Circuit Court of the state of Oregon for the County of
Lane.
Warranty limitations may not apply in your area. This warranty gives you specific legal rights.
You may also have other rights which vary from state to state.
Purchased from
Date Purchased
Model
Serial Number
Installed by
PLEASE KEEP THIS FOR YOUR RECORDS