Bradley Smoker Water Heater S19 690H User Manual

Installation  
Instructions  
S19-690LHS, S19-690H  
10-Gallon Tank with  
Eye Wash and Optional  
Heater Jacket  
S19-690LHS  
Table of Contents  
Pre-Installation Information . . . . . . . . . . . . . . .2  
Installation Instructions . . . . . . . . . . . . . . . . .3–4  
Maintenance Instructions . . . . . . . . . . . . . . . . .5  
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . .5  
Assembly of Components . . . . . . . . . . . . . . . .6  
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
IMPORTANT  
This equipment should be inspected,  
tested, and recorded weekly to maintain  
proper operation.  
Read this installation manual thoroughly  
before beginning installation.  
S19-690H  
This installation manual should be filed  
by the owner’s maintenance department.  
P.O. Box 309, Menomonee Falls, WI 53052-0309  
TEL. 1-800-BRADLEY FAX 262-251-5817  
215-084 Rev. L; EN 02-586  
Page 1 of 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10-Gallon Tank with Eye Wash and Optional Heater Jacket  
S19-690LHS, S19-690H  
Installation Instructions  
Installation Instructions  
Step 1: Install eye wash  
1. Attach the eye wash to the tank  
outlet with pipe sealant (supplied  
by installer) (see Figure 1).  
Back View  
IMPORTANT: When attaching the  
eye wash to the tank outlet, hold  
the adapter (Item 3) with a  
wrench to prevent stripping.  
Failure to do so may damage  
the seal and cause leakage.  
2. Attach the pressure gauge to the  
adapter on the pressure side of the  
tank with pipe sealant (supplied  
by installer) as shown in Figure  
2 on page 6.  
3. FOR OPTIONAL HEATER  
JACKET:  
• Secure the pipe insulation and  
yellow jacket to the eye wash  
assembly.  
• Wrap the heater belt around  
the tank at a height of four  
inches from the bottom of the  
tank and fasten securely.  
• Connect the heat trace cable to  
the junction box.  
• Slide the jacket up the side of  
the tank and pull the draw-  
string at the top of the jacket.  
Figure 1  
• Place the junction box in the  
pocket on the inside of the  
jacket.  
Bradley Corporation • 215-084 Rev. L; EN 02-586  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
10-Gallon Tank with Eye Wash and Optional Heater Jacket  
S19-690LHS, S19-690H  
Installation Instructions  
Installation Instructions continued . . .  
Step 2: Fill tank and pressurize  
1. If the tank is pressurized, relieve the tank pressure by pulling up on the relief tank tab in the  
center of the cover until the pressure gauge reads “0.”  
IMPORTANT: DO NOT open the cover until the pressure gauge reads “0”!  
2. Open the tank by pulling up on the wire handle located on top of the Quicklock cover. Push  
down, rotate and remove. Fill the container with 7 gallons of potable water. Replace the cover.  
3. Pressurize the tank to 95 PSI by applying air pressure to the valve located beneath the pressure gauge.  
NOTE: Relief valve is designed to automatically vent at 100-130 PSI to prevent the tank from over-  
pressurizing.  
Step 3: Flush tank  
1. Discharge the water through the eye wash for at least five minutes to flush the system.  
2. Refill the tank and pressurize as explained in Step 2 outlined above.  
NOTE: Let unit stand for one hour. If there is a noticeable pressure drop, repressurize back to 95 PSI  
and let stand for one hour. If problems persist, consult the Troubleshooting guide found on page 5.  
NOTE: This unit will provide at least 15 minutes of cleansing action. Take the injured person immediately  
to a normal emergency station for additional cleansing and treatment.  
3. FOR OPTIONAL HEATER JACKET: Plug the jacket’s electrical cord into an electric outlet.  
4
Bradley Corporation • 215-084 Rev. L; EN 02-586  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10-Gallon Tank with Eye Wash and Optional Heater Jacket  
S19-690LHS, S19-690H  
Installation Instructions  
Maintenance Instructions  
WARNING: Water preservatives protect potable water from bacteria, fungi and algae  
growth for up to four months. If a water preservative is not used with this eye wash, it is  
recommended that the tank be cleaned weekly or as often as needed. Infection, loss of  
vision or other serious injury may result from misuse of this eye wash. DO NOT use  
expired, cloudy, colored or contaminated solution. DO NOT open preservative bottle if  
safety seal is broken. DO NOT save unused solution.  
Step 1: Inspect eye wash unit  
1. Visually inspect the pressure gauge weekly to ensure the unit is maintaining the proper pressure.  
If the unit is not working properly, remove it from the hazard area immediately and refer to the  
troubleshooting instructions. For further assistance, contact the Bradley Corporation.  
Step 2: Clean eye wash unit  
When using potable water only:  
1. Empty the tank any time from once per week to once per month, depending on the quality of  
your water supply. The manufacturer is not responsible for variations in the water supply.  
2. Clean the inside of the tank using warm water and mild soap. Rinse the tank thoroughly with  
warm water.  
3. Refill the eye wash tank following the procedure outlined in Step 2 found on page 4.  
When using potable water and water preservative (recommended):  
1. Empty the tank at least once every 120 days.  
2. Clean the inside of the tank using warm water and mild soap. Rinse the tank thoroughly with  
warm water.  
3. Refill the eye wash tank with potable water and the contents of an 8-ounce bottle of water  
preservative (refer to the procedure outlined in Step 2 found on page 4).  
• To order potable water preservative, contact your Bradley representative or local distributor  
and ask for part number S19-865.  
Troubleshooting  
1. If pressure relief valve relieves prior to the required pressure, do the following (when in the  
unpressurized condition):  
• Tighten the valve completely into the cap by turning the gray hex head portion of the pressure  
relief valve clockwise. Do not use a wrench.  
• Pull up on the relief valve ring and ensure that the ring is not preventing the valve from closing  
completely. Push on the center pin of the relief valve to ensure that it is completely closed.  
Repressurize tank to required pressure. This may have to be done several times to get the valve  
to seat completely.  
2. If the pressurized tank loses pressure over time, check the connections with diluted liquid dish  
soap or children’s bubbles to identify the leak location. Tighten the connection slightly and test  
again.  
Bradley Corporation • 215-084 Rev. L; EN 02-586  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
10-Gallon Tank with Eye Wash and Optional Heater Jacket  
S19-690LHS, S19-690H  
Installation Instructions  
Assembly of Components  
Figure 2  
Parts List  
Item Part No.  
Qty  
1
Description  
Item Part No.  
Qty  
2
Description  
1
2
3
4
5
6
7
8
S27-252  
153-429  
153-217  
169-786  
S27-161  
204-095  
169-043  
S05-116  
TANK – 10 GALLON  
ADAPTER  
9
107-371  
269-1671  
261-007B  
S83-167  
230-022  
269-1669  
204-421  
114-051  
TETHERED DUST COVER  
PIPE WRAP  
1
10  
11  
1
1
ADAPTER  
1
HEATER BELT, 4 "  
JUNCTION BOX ASSEMBLY  
POWER SUPPLY CORD  
HEATER JACKET  
1
PRESSURE GAUGE  
TANK VALVE ASSY.  
OPERATING INSTR. LABEL  
PIPE PLUG, 1-3/8"  
EYE WASH VALVE ASSY.  
12  
13  
14  
15*  
16*  
1
1
1
1
1
1
1
EMERGENCY TAG  
SAFETY SIGN  
1
1
* Not Shown  
6
Bradley Corporation • 215-084 Rev. L; EN 02-586  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Beko Washer 2012 CX User Manual
Black Box Electronic Accessory ACX1000 User Manual
Black Decker Paper Shredder 8D 150 User Manual
Blaupunkt Car Stereo System Mnchen CD51 User Manual
Bosch Appliances Dishwasher SHE98M User Manual
Bravetti Cookware CW21HCH User Manual
Brinkmann Grill Accessory 815 3610 0 User Manual
Brother Printer PT 3600 User Manual
Cateye Work Light HL NC200 User Manual
Chromalox Electric Heater PB402 4 User Manual