Bradford White Corp Water Heater TGHE 160E NX User Manual

Bradford White EverHotCondensing Tankless Gas Water Heater  
For Exterior Installation  
TGHE-160E-N(X) and TGHE-199E-N(X)  
WARNING: If the information in these  
instructions is not followed exactly, a fire or  
explosion may result causing property  
damage, personal injury or death.  
Do not store or use gasoline or other  
flammable vapors and liquids in the vicinity of this  
or any other appliance  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any appliance.  
Do not touch any electrical switch; do not use  
any phone in your building.  
Ambler, PA 19002  
Tech. Service (800) 334-3393  
Service Part (800) 538-2020  
Warranty Service (800) 531-2111  
Immediately call your gas supplier from a  
neighbor’s phone. Follow the gas supplier’s  
instructions.  
If you cannot reach your gas supplier, call the  
fire department.  
Installation and service must be performed by a  
qualified installer, service agency, or gas supplier.  
INSTALLATION AND OPERATION INSTRUCTION MANUAL  
With Troubleshooting Guide  
PLACE THESE INSTRUCTIONS ADJACENT TO WATER HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE  
A Spanish language version of these instructions is available by  
contacting Bradford White.  
La versión espãnola de estas instrucciones se puede obtener al  
escribirle a la fábrica cuyo nombre aparece en la placa de.  
238-48794-00C 07/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
DO NOT store or use gasoline or other flammable, combustible, or corrosive vapors and/or  
liquids in the vicinity of this or any other appliance.  
This water heater is for outdoor installation only. Do not install indoors.  
This water heater is equipped with an adjustable thermostat to control water temperature.  
Hot water temperatures required for automatic dishwasher and laundry use can cause scald  
burns resulting in serious personal injury and/or death. The temperature at which injury  
occurs varies with the person’s age and the time of exposure. The slower response time of  
disabled persons increases the hazards to them. NEVER allow small children to use a hot  
water tap, or to draw their own bath water. NEVER leave a child or disabled person  
unattended in a bathtub or shower.  
WARNING  
Improper installation, adjustments, alteration, service or maintenance can cause property  
damage, personal injury or loss of life. Failure to follow all instructions in the proper order can  
cause personal injury or death. Read and understand all instructions, including all those  
provided with the appliance before installing, starting-up, operating, maintaining or servicing  
this appliance. Keep this manual and literature in legible condition with this water heater for  
reference by owner and service technician.  
This water heater requires regular maintenance and service to operate safely. Follow the  
instructions contained in this manual.  
Installation, maintenance, and service must be performed only by a qualified, skilled and  
knowledgeable installer or service provider.  
Installation is not complete unless a pressure relief valve is installed into the proper location  
in the hot water outlet piping of this water heater.  
It is the responsibility of the installing contractor to see that all controls are correctly installed  
and are properly operating when the installation is complete.  
This water heater is NOT suitable for installation on combustible flooring. Install water heater  
exactly as shown in this manual.  
DO NOT operate this water heater without first being certain it is filled with water.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
DO NOT tamper with or alter the water heater and/or controls.  
DO NOT operate water heater with jumpered or absent controls or safety devices.  
DO NOT operate water heater if any external part has been under water. Immediately call a  
qualified service technician to inspect the water heater and to replace any part of the control  
system including gas controls, which has been under water.  
DO NOT attempt to use this water heater with any gas other than the type listed on the rating  
plate. Do not attempt to convert this water heater for use with a gas other than the type for  
which it is equipped. Failure to use the proper gas can create an unsafe condition resulting in  
property damage, bodily injury, or death. Consult your local gas supplier or gas company if  
there are any questions.  
DO NOT operate this water heater if the input rate exceeds the rate shown on the water  
heater rating plate.  
This water heater contains very hot water under high pressure. Do not unscrew any pipe  
fittings nor attempt to disconnect any components of this water heater without positively  
assuring the water is cool and is not under pressure. Always wear protective clothing and  
equipment when installing, starting up or servicing this water heater to prevent scald injuries.  
Do not rely on the temperature gauges to determine the temperature. Do not touch any  
components unless they are cool.  
Water heater materials of construction, products of combustion and the fuel contain carbon  
monoxide, nitrogen oxides, aldehydes and/or other toxic or harmful substances which can  
cause death or serious injury and which are known to the state of California to cause cancer,  
birth defects and other reproductive harm. Always use proper safety clothing, respirators and  
equipment when servicing or working nearby this water heater.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
Liquefied petroleum gases/propane gas is heavier than air and will remain at floor level if  
there is a leak. Basements, crawl spaces, closets and areas below ground level will serve as  
pockets for accumulation of leaking gas. Before lighting, smell all around the appliance area  
for gas. Be sure to smell next to the floor.  
IF YOU SMELL GAS:  
DO NOT try to light any appliance.  
DO NOT touch any electric switch; do not use any telephone in your building.  
Immediately call your gas supplier from a telephone in another building. Follow the  
gas supplier’s instructions.  
If you cannot reach your gas supplier, call the fire department.  
DO NOT OPERATE THE APPLIANCE UNTIL THE LEAKAGE IS CORRECTED!  
WARNING  
Flammable items, pressurized containers or any other potential fire hazardous articles must  
never be placed on or adjacent to the water heater. Open containers of flammable material  
must not be stored or used in the same room with this water heater.  
DO NOT USE AN INSULATION BLANKET WITH THIS WATER HEATER. This water heater  
meets or exceeds the ASHRAE/IES 90.1b (latest edition) standards with respect to insulation  
and standby loss requirements.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION II: SPECIFICATIONS  
Table 1. Specifications.  
TGHE-160E-N(X)  
TGHE-199E-N(X)  
Model  
Minimum Rate Btu/h  
9,500 (Natural) / 10,300 (Propane)  
Maximum Rate Btu/h  
157,000  
199,000  
Flow Rate (Min-Max) *  
Flow Rate (45°F rise)  
Default Temperature Setting  
0.4-8.0 GPM (1.5-30 L/min)  
6.6 GPM (25 L/min)  
0.4-9.8 GPM (1.5-37 L/min)  
8.5 GPM (32 L/min)  
104°F (40°C)  
185°F (85°C)  
Maximum Temp Setting (commercial  
**)  
Maximum Temp Setting (residential)  
Minimum Temperature Setting  
Weight  
Selectable at 120°F (49°C) or 140°F (60°C)  
98°F (37°C)  
64 lb (29 kg)  
71 lb (32.2 kg)  
0.94  
Energy Factor  
0.96  
Thermal Efficiency  
Noise level (inside rating)  
Normal  
95%  
50 dB  
44 W  
59 W  
Electrical  
Standby  
2 W  
Consumption  
Anti-frost Protection  
172 W  
172 W  
By-Pass Control  
Electronic  
Minimum Gas  
Supply  
Pressure  
Maximum Gas  
Supply  
Natural Gas  
Propane  
5.0 inch W.C.  
8.0 inch W.C.  
10.5 inch W.C.  
13.5 inch W.C.  
Natural Gas  
Propane  
Pressure  
Condensing, Tankless, Direct Vent, Temperature controlled continuous flow gas  
water heater  
Type of Appliance  
Operation  
With or without remote controls, mounted in kitchen, bathroom, etc.  
Natural Gas or Propane - ensure unit matches gas type supplied at the installation  
location.  
Approved Gas Type  
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4"  
MNPT  
Connections  
Ignition System  
Direct Spark Ignition  
Water Heater: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)  
Simulation Feedforward and Feedback  
50 PSI (Recommended 60-80 PSI for maximum performance)  
150 PSI  
Electric Connections  
Water Temperature Control  
Minimum Water Supply Pressure  
Maximum Water Supply Pressure  
Remote Control Cable  
Non-Polarized Two Core Cable (Minimum 22 AWG)  
Yes  
ENERGY STAR® Qualified  
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.  
** For commercial and hydronic applications requiring higher temperatures. Requires the use of an optional controller  
(P/N 239-48789-00).  
Bradford White Corporation is continually updating and improving products. Therefore, specifications are subject to  
change without prior notice.  
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value  
listed is for the purpose of input adjustment.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions  
TGHE-160E-N(X), TGHE-199E-N(X)  
Table 2. Water Heater Dimensions.  
TGHE-160E-N(X)  
TGHE-199E-N(X)  
DIM  
DESCRIPTION  
In. (mm)  
in. (mm)  
A
B
C
D
E
F
G
H
I
Width  
Depth  
18 ½ (470)  
10 5/8 (271.9)  
26 3/8 (670)  
28 3/8 (721.6)  
4 ½ (115)  
18 ½ (470)  
10 5/8 (271.9)  
26 3/8 (670)  
28 3/8 (721.6)  
4 ½ (115)  
Height - Unit  
Height - with brackets  
Hot Water Outlet - from wall  
Hot Water Outlet - from center  
Cold Water Inlet - from wall  
Cold Water Inlet - from center  
Gas Connection - from wall  
Gas Connection - from center  
From base to gas connection  
From base to cold connection  
From base to hot connection  
Condensate Drain – from wall  
3 7/8 (100)  
3 (75.0)  
3 7/8 (100)  
3 (75.0)  
½ (12.8)  
1 1/16 (27.7)  
4 1/16 (104)  
4 1/16 (104)  
1 5/8 (40.2)  
2 (50.2)  
4 1/16 (104)  
4 1/16 (104)  
1 5/8 (40.2)  
2 (50.2)  
J
K
1 5/8 (41.2)  
5 3/8 (137.6)  
1 5/8 (41.2)  
5 3/8 (137.6)  
7 11/16 (195)  
L
M
Condensate Drain – from center  
7 11/16 (195)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
TGHE-199E-N(X)  
TGHE-160E-N(X)  
Figure 1. Graph Showing Pressure Drop v. Water Flow Rate.  
TGHE-199E-N(X)  
TGHE-160E-N(X)  
Temperature Rise (°F)  
Figure 2. Graph Showing Water Flow Rate v. Temperature Rise.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION III: INSTALLATION INSTRUCTIONS  
WARNING  
INSTALLATION OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A  
LICENSED PLUMBER. Plumbing, air supply, venting, gas supply and electrical work are required.  
DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE NOT CERTAIN OF THE  
FOLLOWING:  
Liquefied petroleum gases/propane gas and natural gas have an odorant added by the gas  
supplier that aids in detection of the gas.  
Most people recognize this odor as a “sulfur” or “rotten egg” smell.  
Other conditions, such as “odorant fade” can cause the odorant to diminish in intensity, or  
“fade”, and not be as readily detectable.  
If you have a diminished sense of smell, or are in any way unsure of the presence of gas,  
immediately contact your gas supplier from a telephone in another building.  
Gas detectors are available. Contact your gas supplier or plumbing professional for more  
information.  
Liquefied petroleum gases/propane gas is heavier than air and will remain at floor level if there is a  
leak. Basements, crawl spaces, closets and areas below ground level will serve as pockets for  
accumulation of leaking gas. Before lighting, smell all around the appliance area for gas. Be sure  
to smell next to the floor.  
IF YOU SMELL GAS:  
Do not try to light any appliance.  
Do not touch any electric switch; do not use any telephone in your building.  
Immediately call your gas supplier from a telephone in another building. Follow the gas  
supplier’s instructions.  
If you cannot reach your gas supplier, call the fire department.  
DO NOT OPERATE THE APPLIANCE UNTIL THE LEAKAGE IS CORRECTED!  
CAUTION  
If building cold water supply has a back-flow preventer, check valve or water meter with check valve,  
provisions for thermal expansion of water in the hot water system must be provided.  
WARNING  
Pressure relief valve discharge piping must be piped near ground or drain to eliminate potential of  
severe burns. Insulate and use electrical heat tape around the discharge drain pipe in any area  
where freezing could occur. Do not install any shut-off valves, plugs or caps to the temperature and  
pressure relief valve or piping.  
DANGER  
Temperature setting should not exceed safe temperature at fixtures. See water temperature control  
warning in the “Temperature Adjustment” section of this Installation and Operation Instruction  
Manual. If higher preheat temperatures are necessary to obtain adequate booster output, add an  
ASSE approved mixing valve for hot water supplied to fixtures.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
Residential use water heaters are suitable for potable water heating only. DO NOT use a  
residential use water heater for space heating or combination space heating/domestic water  
heating. Commercial use water heaters may be used for space heating or combination space  
heating/domestic water heating. Refer to the instructions for space heating in this Installation  
and Operation Instruction Manual.  
This water heater is not suitable for use in pool or spa applications.  
This water heater must be installed outdoors. Failure to properly install this water heater  
outdoors may result in property damage, personal injury, or death. Refer to the installation of  
the water heater in this Installation and Operation manual for details on the location and  
installation outdoors. Do not install indoors.  
UNPACKING  
INSPECT SHIPMENT carefully for any signs of damage.  
1. All equipment is carefully manufactured, inspected and packed.  
2. Any claims for damage or shortage in shipment must be filed immediately with Bradford White  
Corporation and noted on the Bill of Lading.  
WATER HEATER LOCATION  
1. This water heater must be installed outdoors.  
2. The water heater must be installed on a wall capable of supporting up to 71 pounds (32 kg),  
depending on model. Locate the water heater at a height convenient for servicing and above the  
reach of small children.  
3. Refer to Table 3 for minimum installation clearances.  
4. If the water heater is installed in a confined space, such as a closet, ventilation air must be  
provided to prevent increased room temperature. Excessive ambient temperatures surrounding  
the water heater may shorten the life of the controls.  
REMOVE CARTON  
Move water heater to a location near where it will be installed. Carefully slide water heater out from the  
carton and remove all the contents.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MOUNT WATER HEATER ON THE WALL  
This water heater must be installed outdoors. Refer to Table 3 clearances under overhangs, windows,  
doors, etc. Also, avoid locations where there is heavy water run-off from roofs. Determine the proper  
height and location for the water heater to be installed. Consider the water and gas connections. Allow  
enough room for servicing the water heater and maintain the clearances from combustible materials.  
The water heater is supported on the wall by means of a top and bottom slotted angle bracket. For  
convenience, the center hole of the bracket is slotted so that a center screw may be first installed in the  
wall for hanging the water heater on the wall. Two more screws are then added on the ends of the  
bracket to secure the water heater. Wall anchors should be used for the bracket holes unless the bracket  
lines up with a stud. As an alternative, a suitable piece of plywood may be cut to span the wall studs and  
the brackets fastened to the plywood. Make sure the anchors are rated to support up to 71 pound (32 kg)  
weight of the water heater.  
Table 3. Water Heater Clearances.  
to Non-  
Combustibles  
to Combustibles  
TGHE-160E-N(X)  
TGHE-199E-N(X)  
TGHE-160E-N(X)  
TGHE-199E-N(X)  
Top of Water  
Heater  
12 inches  
(305 mm)  
2 inches  
(51 mm)  
Back of Water  
Heater  
0 (zero)  
0 (zero)  
0 (zero)  
Front of Water  
Heater (panel)  
24 inches  
(610 mm)  
Front of Water  
Heater  
(exhaust)  
24 inches  
(610 mm)  
24 inches  
(610 mm)  
Sides of Water  
Heater  
6 inches  
(152 mm)  
1/8 inch  
(3.2 mm)  
12 inches  
(305 mm)  
2 inches  
(51 mm)  
Floor/Ground  
NOTICE  
The recommended minimum clearance for servicing is 24 inches (610 mm) in front of the water  
heater.  
WARNING  
For all closet installations, follow the minimum clearances to combustibles whether the closet door is  
combustible or non-combustible.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
State Regulations  
NOTICE BEFORE INSTALLATION  
Bradford White direct-vent appliance must be installed by a state qualified or licensed contractor. If you  
are not properly trained, you must not install this unit.  
IMPORTANT: In the State of Massachusetts (248CMR 4.00 & 5.00)  
For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or  
structure used in whole or in part for residential purposes, including those owned or operated by the  
Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above  
finished grade in the area of venting, including but not limited to decks and porches, the following  
requirements must be satisfied:  
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side  
wall horizontal vented gas fueled equipment, the installing plumber or gas fitter must observe that  
a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor  
level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter  
must observe that a battery operated or hard wired carbon monoxide detector with an alarm is  
installed on each additional level of the dwelling, building or structure served by the property  
owner to secure the services of qualified licensed professionals for the installation of hard wired  
carbon monoxide detectors. It is the responsibility of the property owner to secure the services of  
qualified licensed professionals for the installation of hard wired carbon monoxide detectors.  
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a  
crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery  
back-up may be installed on the next adjacent floor level.  
b. In the event that the requirements of this subdivision cannot be met at the time of  
completion of installation, the owner shall have a period of thirty (30) days to comply with  
the above requirements; provided, however, that during said thirty (30) day period, a  
battery operated carbon monoxide detector with an alarm must be installed.  
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required  
in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed  
and IAS certified.  
3. SIGNAGE. A metal or plastic identification plate must be permanently mounted to the exterior of  
the building at a minimum height of eight (8) feet above grade directly in line with the exhaust  
vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign  
must read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW.  
KEEP CLEAR OF ALL OBSTRUCTIONS”.  
INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment  
shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide  
detectors and signage installed in accordance with the provisions of 248 CMR 5308(2)(a)1 through 4.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VENT TERMINAL  
AIR SUPPLY INLET  
AREA WHERE  
TERMINAL IS NOT  
PERMITTED  
Figure 3. Installation Clearances.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 4. Installation Clearances.  
Canadian  
Installations  
US  
Ref  
A
Description  
Installations  
Clearance above grade, veranda,  
porch, deck, or balcony  
12 inches  
(30 cm)  
12 inches  
(30 cm)  
Clearance to window or door that  
may be opened  
36 inches  
(91 cm)  
12 inches  
(30 cm)  
B
Clearance to permanently closed  
window  
C
*
*
Vertical clearance to ventilated  
soffit, located above the terminal  
within a horizontal distance of 2  
feet (61 cm) from the center line of  
the terminal  
D
*
*
E
F
Clearance to unventilated soffit  
Clearance to outside corner  
Clearance to inside corner  
*
*
*
*
*
*
G
3 feet (91 cm)  
within a height  
15 feet (4.5 m)  
above the  
meter/regulator  
assembly  
Clearance to each side of center  
line extended above  
H
*
*
meter/regulator assembly  
Clearance to service regulator vent  
outlet  
36 inches  
(91 cm)  
I
Clearance to non-mechanical air  
supply inlet to building or the  
combustion air inlet to any other  
appliance  
36 inches  
(91 cm)  
12 inches  
(30 cm)  
J
3 feet (91  
cm) above if  
6 feet (1.83 m) within 10 feet  
Clearance to a mechanical air  
supply inlet  
K
(3 m)  
horizontally  
Clearance above paved sidewalk  
or paved driveway located on  
public property  
7 feet  
(2.13 m)  
L
*
Clearance under veranda, porch,  
deck, or balcony  
12 inches  
*
M
(30 cm) ▲  
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two  
single family dwelling and serves both dwellings.  
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the  
floor.  
* For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1 (latest editions), clearances are in  
accordance with local installation codes and the requirements of the gas supplier.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Local codes supersede these clearances.  
Avoid termination locations near a dryer vent.  
Avoid termination locations near commercial cooking exhausts.  
(0.91 m) to ventilated or unventilated soffit or eve  
vent or to a deck or porch  
*
36"  
12"  
(0.30 m) to  
an inside  
2"  
(50 mm) between terminals at same level  
INSIDE  
CORNER  
Figure 4. Additional Installation Clearances.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
High Altitude Installations  
The default setting for the water is 0-2,000 ft (0-610 m) with dip switch numbers 2 and 3 in the OFF  
position. If this water heater is installed at a higher altitude, it is necessary to modify the dip switch  
settings according to Table 5.  
Table 5. Dip Switch Settings for High Altitude Installations.  
0-2000 ft  
(0-610 m)  
2001-5200 ft  
(610-1585 m)  
5201-7700 ft  
(1585-2347 m)  
7701-10200 ft  
(2347-3109 m)  
Switch No. 2  
Switch No. 3  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
Switch No.  
Switch No.  
Switch No.  
Switch No.  
ON  
ON  
ON  
ON  
O
F
F
O
F
F
O
F
F
O
F
F
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION IV: WATER CONNECTIONS  
WARNING  
Failure to install and maintain a new, listed pressure relief valve will release the manufacturer from  
any claim, which might result from excessive temperature and pressures.  
Keep clear of the pressure relief valve discharge line outlet. The discharge may be hot enough to  
cause scald injury. The water is under pressure and may splash.  
WARNING  
DO NOT reverse the inlet and outlet (cold and hot water) connections on the water heater. This may  
cause a hazardous operating condition or the water heater may be inoperable  
WATER QUALITY  
The EverHotwater heater must have the water quality within the following limits for long life and reliable  
operation. The water supply should be tested to make sure the quality is within the specified limits. If  
there is a problem with the water quality, contact your local water conditioning company for equipment to  
condition the water supply to this appliance.  
NOTICE  
Operating this water heater with water conditions outside the specified limits will void the warranty.  
Table 6. Maximum Levels for Water Quality.  
TDS  
(Total  
Dissolved Hardness  
Solids)  
Total  
Description  
pH  
Aluminum Chlorides Copper  
Iron  
Manganese  
Zinc  
Up to  
0.3  
ppm  
Maximum  
Levels  
6.5 to Up to 500  
8.5 ppm  
Up to  
200 ppm  
Up to 0.2  
ppm  
Up to  
250 ppm 1.0 ppm  
Up to  
Up to 0.05  
ppm  
Up to 5  
ppm  
Note: 1 ppm = 1 mg/L  
NOTICE  
If the EverHot water heater is operated under hard water conditions without a water conditioner, the  
diagnostic code “LC” may flash on the water heater’s control. This code means the heat exchanger coil  
is beginning to accumulate mineral deposits and MUST be flushed (see Section VIII, “Flushing  
Procedure for Mineral Scale Removal…”). Contact your installer for a qualified service technician to  
flush the heat exchanger. A water conditioner may be needed to prevent this condition from re-  
occurring.  
CAUTION  
Failure to flush the water heater when “LC” is flashing will cause damage to the heat exchanger.  
Damage caused by mineral scale build up is not covered by the water heater warranty.  
INSTRUCTIONS FOR CONNECTIONS  
1. BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY  
VALVE. After shutting off the main water supply, open a faucet to relieve the water line pressure  
to prevent any water from leaking out of the pipes while making the water connections to the  
water heater. The COLD water inlet and HOT water outlet are identified on the bottom casing of  
the water heater. Make the proper plumbing connections between the water heater and the  
plumbing system to the house. All soldering materials and piping must be compatible with  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
potable water. Unions should be installed on both the hot and cold water lines for future servicing  
and disconnection of the water heater. Install a shut-off valve in the cold water supply line.  
2. In order to service the water heater in the event the heat exchanger needs to be flushed of  
mineral deposits, tee fittings with shut-off valves and service connections to hoses should be  
installed. Also, install a shut-off valve to the hot water supply to isolate the service tee fittings. A  
plumbing installation kit, which includes these fittings and a pressure relief valve, is available from  
your supplier. Refer to the piping diagrams in Section IV, “Water Connections”.  
3. Install a pressure relief valve on a tee connection from the hot water outlet piping from the water  
heater. Refer to the piping diagrams (Figure 6 and Figure 7) and pressure relief valve warning in  
Section IV, “Water Connections.”  
4. In cold climates, where piping can freeze during an extended power failure, drain solenoid valves  
should be installed on the cold and hot water supply lines to allow water to drain from the water  
heater when power is interrupted. Refer to the piping diagram (Figure 8) “Recommended Piping  
for Power Failure Freeze Protection” in Section IV, and contact your Bradford White dealer if  
assistance is needed.  
5. If this water heater is installed in a closed water supply system, such as the one having a back-  
flow preventer in the cold water supply, provisions must be made to control thermal expansion.  
DO NOT operate this water heater in a closed system without provisions for controlling thermal  
expansion. Warranties do not cover damages from thermal expansions, such as pressure bulges  
and/or deformities. Your water supplier or local plumbing inspector should be contacted on how  
to control this situation.  
6. Purge the cold water line prior to connecting to the water heater to remove debris. Debris will  
clog the mesh strainer of the inlet filter. The inlet strainer prevents debris from damaging the flow  
sensor or clogging the coil. It may need to be cleaned periodically and should be cleaned after  
the initial operation. DO NOT operate the water heater without the filter in place. In areas where  
sediment may be periodically present in the water supply, a Y-type strainer (#20 mesh) or  
cartridge filter should be installed on the cold water inlet to the water heater to prevent the water  
heater fine mesh strainer from getting plugged and restricting water flow.  
7. After installation of the water lines, open the main water supply valve and fill the water heater.  
While the water heater is filling, open several hot water faucets to allow air to escape from the  
water system. When a steady stream of water flows through the faucets, close them and check  
all water connections for possible leaks.  
8. This water heater may also be connected to a circulating pump or storage tank for increased flow  
capacity during high demand periods.  
9. Commercial installations may require more than one water heater piped together in a manifold to  
supply enough capacity for high temperature and high water flow applications. Special controls  
are available from your Bradford White supplier for operating more than one water heater  
together. These controls stage the operation of the water heaters for the flow rates and control  
the amount of flow through each water heater. Order p/n MSA-2M for the electronic manifold  
control for the first and second water heater and p/n MSA-2S for the wiring harness for each  
additional water heater to be controlled. A maximum of (5) water heaters can be connected  
together. Alternatively, to connect only (2) water heaters, an EZConnectTM harness, p/n REU-  
EZC-1US, can be used. Instructions are included with these parts.  
NOTICE  
Take care when using pipe dope or thread sealing tape to avoid clogging the inlet screen and water  
flow sensor. Wipe off excess pipe dope from threads before connecting to the water heater.  
Commercial dishwashers will require either more than one water heater, or a storage tank to supply a  
sufficient volume of hot water.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 5. Scald Warning.  
Table 7. Approximate scald time/temperatures.  
APPROXIMATE TIME/TEMPERATURE  
RELATIONSHIPS IN SCALDS  
More than 5 minutes  
1½ to 2 minutes  
120°F (49C)  
125°F (52C)  
130°F (54C)  
135°F (57C)  
140°F (60C)  
145°F (63C)  
150°F (66C)  
155°F (68C)  
About 30 seconds  
About 10 seconds  
Less than 5 seconds  
Less than 3 seconds  
About 1½ seconds  
About 1 second  
Condensate  
The TGHE series water heaters are factory equipped with a condensate trap and drain line. All  
condensate must drain and be disposed of per local codes. Use only vent that is approved venting; do  
not use PVC, CPVC, ABS, or galvanized material to vent this appliance.  
If the condensate drain gets blocked, an error code will display on the controller. If this occurs, the  
condensate drain must be cleaned. The condensate trap will automatically prime during operation of the  
unit as condensate forms. Condensate draining from the unit indicates that the trap is full and that there  
is no blockage in the condensate drain.  
Use only PVC or CPVC pipe for the condensate drain line. The drain pipe, along its entire length, must  
be at least the same diameter as the drain line (1/2” NPT). The drain pipe must be as short as possible  
and have a downward pitch. The end of the drain pipe must be open to the atmosphere. The end must  
not be underwater or other substances. Do not connect the drain pipe directly to the rain sewer. Do not  
connect the condensate drain line with an air conditioning evaporator coil drain.  
To minimize freezing of the condensate, run the condensate drain line through an interior wall or between  
insulation and an interior wall.  
NOTICE  
Do not plug or cap the integrated condensate line. Without proper drainage or disposal, condensate  
will damage the water heater.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 6. Recommended Piping for a Basic Installation.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pump to be of bronze or  
stainless construction  
Figure 7. Recommended Piping for a Circulation Systems.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recommended Piping for Power Failure Freeze Protection  
As long as electrical power and gas are supplied to the EverHotwater heater, freeze protection is  
provided to the heat exchanger and piping inside the water heater with ambient temperatures as cold as  
-4F (-20C), when protected from direct wind exposure. In the event of a power failure with ambient  
temperatures below freezing, the water heater must be drained of all water to prevent freeze damage.  
The water heater may be drained manually, or automatically, through the installation of the optional  
solenoid valves, as shown in the following illustration. The drain solenoids are recommended for very  
cold climates to prevent water heater freeze damage where power failures from ice and windstorms  
occur.  
The electrical connections for the two solenoids must be tied to the 120 volt main power supply (black  
and white wires). When the electrical power to the water heater fails, the ¾” solenoid on the cold water  
inlet pipe closes, stopping water flow into the water heater. The drain solenoid opens, allowing the water  
heater and connected piping to drain. Make sure the piping from the drain solenoid is run to a suitable  
drain or outside the building to prevent water damage.  
Figure 8. Recommended Piping for Freeze Protection.  
CAUTION  
Heat trace all water pipe and fittings located outside the home (attic, crawl space) or building  
structure. All pipe and fittings shown below dashed line (see Figure 8) should be located inside  
home or building structure. The vacuum breaker line should be located inside the building structure.  
All piping located outside the building must be insulated and wrapped with heat tape to prevent  
freezing.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRESSURE RELIEF VALVE  
WARNING  
Keep clear of the pressure relief valve discharge line outlet. The discharge may be hot  
enough to cause scald injury. The water is under pressure and may splash.  
For protection against excessive pressure, install pressure protective equipment required by  
local codes, but not less than a pressure relief valve certified by a nationally recognized  
testing laboratory that maintains periodic inspection of production of listed equipment or  
materials as meeting the requirements of the Standard for Relief Valves and Automatic Gas  
Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 and the Standard CAN1-4.4  
Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves.  
The pressure relief valve must be marked with a maximum set pressure not to exceed the  
maximum working pressure of the water heater. The pressure relief valve rating must not be  
less than the hourly rating of the water heater.  
Install the pressure relief valve into a tee connection from the hot water outlet of the water  
heater.  
Note: Some models may already be equipped or supplied with an installed pressure relief  
valve. Verify that the pressure relief valve complies with local codes. If the pressure relief  
valve does not comply with local codes, replace it with one that does. Follow the installation  
instructions in the following paragraph.  
Install a discharge line so that water discharged from the pressure relief valve will exit within  
six (6) inches (15.2 cm) above, or any distance below the structural floor and cannot contact  
any live electrical part. The discharge line is to be installed to allow for complete drainage of  
both the combination temperature and pressure relief valve and the discharge line. The  
discharge opening must not be subjected to blockage or freezing. DO NOT thread, plug or  
cap the discharge line. It is recommended that a minimum clearance of four (4) inches (10.2  
cm) be provided on the side of the water heater for servicing and maintenance of the  
pressure relief valve.  
DO NOT place a valve between the pressure relief valve and the hot water outlet!  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Combination Water and Space Heating Applications – Commercial Use Water Heaters Only  
Commercial use water heaters may be used for space heating or combination space heating/potable water  
heating applications, provided the following requirements and recommended piping diagrams are carefully  
followed.  
WARNING  
The following instructions must be carefully followed to assure safe and reliable operation of the  
water heater. All piping components connected to this water heater must be suitable for use with  
potable water. In Massachusetts, space heating piping length must not exceed 50 feet. Toxic  
chemicals, such as those used for boiler treatment, must not be introduced into potable water used  
for space heating. This water heater must not be connected to an existing heating system or  
component(s) previously used with a non-potable water heating appliance. When the system  
requires water for space heating at temperatures higher than required for other means, an ASSE  
approved mixing valve must be installed to temper the water for those uses in order to reduce the  
scald hazard potential.  
1. Only commercial use water heaters may be used for combination water heating/space heating  
applications. Residential use water heaters will not be covered under warranty for water heating/space  
heating applications.  
2. The temperature setting of the water heater thermostat must not exceed 160F.  
3. In combination space heating/potable water heating applications that require higher water temperatures  
than normally used for potable water uses, an ASSE approved thermostatic mixing valve must be  
installed to temper the water for those uses in order to reduce the scald hazard potential.  
4. In order to assure adequate flow through the water heater, follow the recommended piping diagram and  
circulator specifications (see Figure 9).  
5. An expansion tank will be required in all space heating applications.  
6. A Y-type mesh strainer (#20 mesh screen) should be installed on the cold water inlet of the water heater  
to prevent clogging of the fine mesh screen on the water heater cold water inlet connection.  
7. A water softener must be used if the water supply has a tested hardness level above 10 grains of  
hardness.  
8. All piping must be ¾” copper or larger.  
9. All components must be suitable for use with potable water.  
10. The water heater should be located as close as practical to the space heating heat exchanger.  
11. A check valve should be located after the circulator(s) to prevent backflow during potable water demands.  
12. A heat exchanger may be required to separate the potable water from the space heating circuit in certain  
applications.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: in Massachusetts, the following must be done:  
Tempered potable water must meet temperatures in 248 CMR.  
All water piping must be insulated in accordance with 780 CMR (Massachusetts energy code).  
50 feet maximum distance from water heater to space heating load (developed length).  
Piping loop between water heater and heating load must be in compliance with 248 CMR.  
All circulators must use an electronically controlled timer that activates every 6 hours for 60 seconds.  
Figure 9. Recommended Piping for Combination Water and Space Heating Applications.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION V: GAS CONNECTIONS  
WARNING  
Connect this water heater only to the type of gas as shown on the rating plate. Use clean black iron  
pipe or equivalent material approved by local codes and ordinances. Dirt and scale from the pipe  
can enter the gas valve and cause it to malfunction. The inlet gas line must have at least a 3 in.  
(7.62 cm) drip leg (sediment trap) installed as close to the water heater’s gas valve as possible. A  
ground joint union must be installed in the gas supply line, as close to the water heater as possible,  
to permit servicing of the water heater. Compounds used on the threaded joints of the gas piping  
must be resistant to the action of liquefied petroleum gases/propane gas. DO NOT apply pipe dope  
to the gas valve inlet, and make certain that no pipe dope has become lodged in the inlet screen of  
the gas valve. Extreme care must be taken to ensure no pipe dope enters the gas valve and to  
avoid excessive torque when tightening the gas supply line to the gas valve. Excessive torque may  
result in cracking of the gas valve housing. The suggested maximum torque is 31.5 ft-lbs. (4.4 kg-  
m). The manufacturer of this water heater will not be liable for any damage or injury caused as a  
result of a cracked gas inlet as a result of excessive torque.  
This water heater and its gas connection must be leak tested before placing the water heater in  
operation. Check for gas leaks with a soap and water solution and a brush or a commercial leak  
detector fluid. NEVER USE A MATCH OR OPEN FLAME FOR TESTING!  
The water heater is not intended for operation at higher than 10.5 inches water column, for natural  
gas, 13.5 inches water column for L.P. supply gas pressure. Higher gas supply pressures require  
supplemental reducing service regulation. Exposure to higher gas supply pressure may cause  
damage to the gas controls, which could result in fire or explosion. If overpressure has occurred,  
such as through improper testing of gas lines or emergency malfunction of the supply system, the  
gas valve must be checked for safe operation. Make sure that the outside vents on the supply  
regulators and the safety vent valves are protected against blockage. These are parts of the gas  
supply system, not the water heater.  
WARNING  
Conversion of this unit from natural gas to L.P. or L.P. to natural gas CANNOT be done in the field.  
If the gas supply does not match the type shown on the water heater rating plate, then contact your  
supplier for the proper water heater for the building gas supply.  
CAUTION  
The water heater and individual shut-off valve must be disconnected from the gas supply piping  
system during any pressure testing of the system at test pressures in excess of ½ psi (3.5 kPa).  
The water heater must be isolated from the gas supply piping system by closing its manual shutoff  
valve during any pressure testing of the gas supply system at test pressures equal to or less than ½  
psi (3.5 kPa). The supply line must be capped when not connected to the water heater.  
If copper supply lines are used, they must be internally tinned and certified for gas service.  
The gas supply lines must meet all requirements of the National Fuel Gas Code ANSI Z223.1-Latest  
Edition, or in Canada Natural Gas Installation Code CAN/CGA B149.1-Latest Edition or Propane  
Installation Code CAN/CGA B149.2-Latest Edition. The gas supply line may need to be larger for  
EverHotwater heaters than a storage water heater in the case of a replacement installation. Refer to  
the piping capacity tables at the end of Section V, “Gas Connections” and in the codes referenced above.  
A 3 in. (7.6 cm) drip leg (sediment trap) is required ahead of the gas inlet connection to the water heater.  
Install a manual gas shut-off valve before the gas inlet connection to the water heater before connecting  
to the gas line. A union should be installed before the water heater gas connection for disconnection for  
servicing.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Check the type of gas and the gas inlet pressure before connecting the EverHot® water heater to the gas  
supply. If the gas supply type does not match the type shown on the water heater rating plate, then DO  
NOT connect the water heater. Contact your Bradford White supplier for the correct water heater.  
GAS METER SIZE – NATURAL GAS ONLY  
Be sure that the gas meter has sufficient capacity to supply the full rated gas input of the water heater, as  
well as the requirements of all other gas fired equipment supplied by the meter. If the gas meter is too  
small, ask the gas company to install a larger meter having adequate capacity.  
GAS PRESSURE REGULATION  
Minimum and maximum gas supply pressures are listed below: The minimum gas pressure specified  
below is required for the full input rating specified on the water heater rating plate.  
Natural Gas: Minimum: 5.0 in. w.c.  
L.P. Gas:  
Minimum: 8.0 in. w.c.  
Maximum: 13.5 in. w.c.  
Maximum: 10.5 in. w.c.  
Before placing the WATER heater in operation, check for gas leakage. Use soap and water solution or  
other material acceptable for the purpose of locating gas leaks.  
WARNING  
DO NOT use matches, candles, flame, or other sources of ignition for this purpose.  
Table 8. Maximum Capacity of Schedule 40 Pipe in CFH for Gas Pressures of ½ psig or Less.  
Length  
0.5 in. W.C. Pressure Drop  
(feet)  
(meters)  
3/4  
1
1 1/4  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
3.0  
6.1  
9.1  
12.2  
15.2  
18.3  
21.3  
24.4  
27.4  
30.5  
360  
250  
200  
170  
151  
138  
125  
118  
110  
103  
680  
465  
375  
320  
285  
260  
240  
220  
205  
195  
1,400  
950  
770  
660  
580  
530  
490  
460  
430  
400  
Table 9. Specific Gravity Correction Factors.  
Specific  
Gravity  
0.50  
Correction  
Factor  
1.10  
Specific  
Gravity  
1.30  
Correction  
Factor  
1.07  
0.55  
1.04  
1.40  
1.04  
0.60  
1.00  
1.50  
1.00  
0.65  
0.96  
1.60  
0.97  
0.70  
0.93  
1.70  
0.94  
0.75  
0.90  
0.80  
0.87  
Note: After determining the length of pipe required, select the pipe size that will supply the CFH (cubic  
feet per hour) of gas required for the input rating of the gas appliances on the line. To determine  
the CFH required for the gas appliances on the line, use the formula, shown below. The heating  
value of the gas used may be obtained from a local gas utility.  
Gas Input of Appliance(s) on the Line (Btu/hr)  
CFH   
Heating Value of Gas (Btu/Cu.ft)  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INITIAL OPERATION AND TESTING (INSTALLER ONLY)  
1. Open the gas and water supply valves to the water heater.  
2. Check for water and gas leaks. Use soap solution to check for gas leaks.  
3. To check inlet supply pressure, remove the 1/8” NPT plug on the gas inlet supply fitting just below  
the bottom casing and install a barb fitting for attaching a hose to a manometer. For checking the  
gas manifold pressure, the plug is located just below the gas manifold connection inside the  
control panel.  
4. Turn power on (after completing electrical connections – refer to Section VI, “Electrical  
Connections”) and fully open a hot water tap.  
5. Measure the gas pressures to see that these are within the specified limits below:  
Supply Pressure:  
Manifold Pressure:  
Nat. Gas: Min.: 5 in. w.c., Max.: 10.5 in. w.c.  
L.P. Gas: Min.: 8 in. w.c., Max: 13.5 in. w.c.  
Nat. Gas: 2.4-3.0 in. w.c. High Fire, 0.61-0.85 in. w.c. Low Fire  
L.P. Gas: 3.6-4.0 in. w.c. High Fire, 0.92-1.46 in. w.c. Low Fire  
(Manifold pressures vary depending on the water heater model)  
6. Turn off the hot water faucets. Disconnect the electrical power to the water heater. Remove the  
pressure gauges and replace the plugs. Check for gas leaks around the plugs.  
7. Replace the front control panel. Restore electrical power to the water heater  
NOTICE  
If the gas supply pressure is below the specified value, check the gas piping to ensure that it is the  
correct size for all the gas appliances on line. Check the supply pressure with all the gas appliances  
in operation. The manifold pressure will vary with the water flow rate. Several hot water faucets  
may need to be opened with the temperature control set on the highest setting in order to get  
maximum high fire manifold pressure. If the manifold pressure is below the specified value and  
there is sufficient water pressure and flow, be sure the inlet gas pressure is within the specified limits  
before attempting to adjust the manifold pressure.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION VI: ELECTRICAL CONNECTIONS  
WARNING  
Turn off or disconnect the electrical power supply to the water heater before servicing. Label all  
wires prior to disconnection when servicing controls. Wiring errors can cause improper and  
dangerous operation. Verify proper operation after servicing.  
All electrical wiring must be installed and grounded in accordance with local codes, or in the  
absence of local codes, the National Electrical Code, ANSI/NFPA 70 (latest edition) and/or CSA  
C22.2 Electrical Code (latest edition).  
The water heater must be wired to a 120 VAC, 60 Hz, 15A power supply. The water heater should be  
connected to a GFI outlet and wired on a separate circuit and breaker. A strain relief will be required for  
the line cord. Do not plug the line cord into a receptacle that can have the power supply interrupted by a  
switch that is used to control lights or another appliance.  
If wiring in conduit is required, install an electrical conduit connector. A disconnect switch should be  
provided near the water heater for servicing. Connect the wires exactly as shown in the wiring diagram of  
this manual and on the inside cover panel. The black wire is the hot leg; the white wire is neutral. A  
green screw is provided in the junction box for the green wire ground connection.  
CAUTION  
Do not energize the electric circuit before the water heater tank is filled with water.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TWIN  
THERMISTOR  
WATER  
LEVEL  
DETECTING  
CIRCUIT  
WATER LEVEL  
ELECTRODE  
Figure 10. Ladder Diagram.  
WARNING  
DO NOT adjust any dipswitch settings on PC board unless instructed to do so.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 11. Wiring Diagram for TGHE Models.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TEMPERATURE CONTROLS  
The included temperature control allows the end user to set the hot water supply temperature and will  
display certain diagnostic codes of the water heater if there is a malfunction. All models have the option  
of up to four controllers that can be used to conveniently control water temperatures for bath and shower  
fixtures.  
The main control is to be at a convenient location inside the installation home or building. The adjustment  
range is 98-120F. Additional remote controls can be purchased, p/n 239-48788-00, and these have the  
same available temperature range as the main control. If an optional commercial control, p/n  
239-48789-00, is purchased, the allowable temperature can be up to 185ºF. If a commercial control is  
used, this reduces the warranty period of the water heater. Also, if a commercial control is used with a  
water heater, all of the remaining controls connected to the water heater can achieve the maximum  
temperature that the commercial control allows. See Table 10 for more details.  
Table 10. Available Temperature Settings for TGHE Models.  
Model  
Temperature Settings Available (°F)  
TGHE-160E-N(X)  
TGHE-199E-N(X)  
150 160 185  
98 100 102 104 106 108 110 115 120 125* 130* 135* 140*  
**  
**  
**  
Temp (ºC)  
37 38  
39  
40  
41  
42  
43  
46  
49  
52  
54  
57  
60  
66  
71  
85  
* Re-setting the Maximum Temperature  
These units have a default maximum temperature of 120º F (49º C) and an option to increase the maximum  
temperature to 140 ºF (60 ºC). Temperature settings from 125-140 ºF (52-60 ºC) are available by setting dip switch 6  
to ON in the SW1 bank of 8 dip switches.  
**239-48789-00, Commercial Control  
These settings require the 239-48789-00 controller. When the 239-48789-00 controller is connected, these higher  
temperatures are available on all controller models in the system. Use of a 239-48789-00 controller in a residential  
dwelling will reduce the warranty coverage to that of a commercial warranty application.  
DANGER  
Hotter water increases the risk of scald injury. Scalding may occur within 5 seconds at a  
temperature setting of 140F (60C). To protect against hot water injury, install a mixing valve in the  
water system. This valve will reduce point of discharge temperature by mixing cold and hot water in  
branch water lines. A licensed plumbing professional or local plumbing authority should be  
consulted.  
CAUTION  
This water heater, when set at a lower temperature setting is not capable of producing hot water of  
sufficient temperature for sanitizing purposes. Always check water temperature by hand before  
entering the shower or bath. The temperature may have been changed. Test the temperature of  
the water with your hand or elbow before placing a child in the bath or shower. Do not leave a child  
or an infirm person in the bath unsupervised.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
Do not adjust this water heater in any residential application above 120ºF. If this water heater is  
used in a commercial application where temperatures in excess of 120ºF are required, use an ASSE  
approved mixing device.  
WARNING  
This water heater is equipped with an energy cut out device to prevent overheating. Should  
overheating occur or the gas supply fails to shut off, turn off the manual gas control valve to the  
water heater, and call a qualified service agency.  
NOTICE  
The lower the temperature setting, the greater the energy efficiency to heat the water. Lower water  
temperatures also extend the heat exchanger life. Remember, no water heating system will provide  
exact temperatures at all times. Allow a few days of operation at this setting to determine the correct  
temperature setting consistent with the requirements for the installation.  
When multiple controls are used, depressing the Priority Button will override the main control and display  
the setpoint of the remote control in use. Both the remote controls and the main control will display  
diagnostic codes in the event the water heater needs service.  
NOTICE  
No more than four temperature controls may be connected to the EverHot® water heater.  
NOTICE  
The default temperature setting that will appear when the water heater is first connected to the electrical  
supply is 104ºF. In the event of a power interruption, the unit will retain its set temperature for up to 6  
hours. If the power is interrupted for more than 6 hours, the unit will revert back to a temperature of  
104°F.  
Before installing optional remote controls, determine the most convenient locations(s). When deciding on  
the best location for the remote controls, please consider the following items:  
1. Place the controls out of reach of small children.  
2. Avoid locations where the control(s) will become hot, such as over a radiator, register, or other  
heat sources.  
3. Avoid direct sunlight. The digital readout can be difficult to read in direct sunlight.  
4. Avoid areas where the remote can be splashed with cooking water, oil, or sauce.  
5. The remote control operates with low voltage.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In Use Indicator  
Priority Button  
Priority Indicator  
Temperature Display  
Figure 12. Remote Control and the Description of Functions on All Controls.  
Residential Control, p/n 239-48788-00  
Commercial Control, p/n 239-48789-00  
Installation of Control(s)  
1. The controls may be wired in parallel only.  
2. Mark the holes on the wall using the control mounting plate and drill two mounting holes using a  
3/32” (2.4 mm) drill bit and a clearance hole for the cable using a ¼” (6.4 mm) drill bit.  
securing screw  
1-21/32"  
wiring hole  
3-5/16"  
securing screw  
Figure 13. Outline of Remote Control's Mounting Plate.  
3. Run the cable from the control to the water heater or another control, which ever is closer or more  
convenient.  
4. Remove the face plate from the control by inserting a screwdriver in the slot and twisting open.  
5. Connect the cable to the terminal screws of the control.  
6. Mount the control to the wall using the holes drilled and with the screws supplied. Note: Plastic  
wall anchors may be required if the control is not located over a stud when mounting on  
wallboard.  
Note: If the cable cannot be run inside the wall cavity, then the plastic knockout should be removed from  
the top or bottom of the control to allow flush mounting with the wall.  
7. Disconnect the power from the water heater and remove the front cover.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Remove the plastic cover from the PCB and electrical connections.  
9. Thread the cable through the access hole at the base of the water heater and connect the wires  
to the control terminals on the right hand side of the PCB.  
REMOTE CONTROL  
CONNECTION TERMINALS  
REMOTE  
CONTROL CABLE  
CABLE CLAMP  
Figure 14. Illustration Showing Where to Connect Remote Control Harness.  
10. Secure the control cable using the clamp provided in the control compartment.  
11. Replace the plastic cover over the PCB terminals and then replace the front control panel of the  
water heater.  
WARNING  
Do not attempt to connect the controls with the power on to the water heater. There is 120 volt  
terminals and wiring next to the remote control connections inside the unit. All servicing and wiring  
must be performed by a qualified installer.  
WARNING  
When the water heater or remotely located remote control is used in public use applications, it shall  
be installed in a location where it cannot be adjusted by the public (i.e. a maintenance room or  
manager’s office). Unauthorized adjustments may result in scalding conditions.  
INITIAL OPERATION AND TESTING OF CONTROLS (INSTALLER ONLY)  
1. Turn on power to the water heater and fully open a hot water tap.  
2. Check the operation of the water heater. Check the operation of the remote temperature  
control(s). Check the operation of the power failure protection system (drain solenoids).  
3. Explain the proper operation of the new Bradford White EverHotwater heater to the end user.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting – Electrical  
There are a number of (live) tests that are required when fault finding this product. Extreme care should  
be used at all times to avoid contact with energized components inside the water heater. Only trained  
and qualified service technicians should attempt to repair this product. Before checking for resistance  
readings, disconnect the power source to the unit and isolate the item from the circuit (unplug it).  
Table 11. (SV1, SV2, SV3, SV4, and POV) Gas Valve and Modulating Solenoids (Set Meter Above 2k).  
Connector  
No.  
Pin  
Nos.  
Wire Color  
Voltage  
Resistance  
(SV0) Pink-Black  
(SV1) Blue-Black  
11-13 VDC  
11-13 VDC  
11-13 VDC  
11-13 VDC  
11-13 VDC  
2-15 VDC  
37-43 ohms  
37-43 ohms  
37-43 ohms  
37-43 ohms  
37-43 ohms  
67-81 ohms  
B5  
B6  
B7  
B3  
B4  
B2  
7-8  
6-7  
(SV2) Yellow-Black  
(SV3) Red-Black  
5-7  
4-7  
(SV4) Orange-Black  
(POV) Orange-Orange  
3-7  
10-11  
Table 12. (M) Water Flow Control Device Servo.  
Connector  
No.  
Pin  
Nos.  
3 or 4-  
8
1 or 2-  
8
Wire Color  
Voltage  
5-7 VDC  
5-7 VDC  
Resistance  
Red or Pink-Orange  
n/a  
n/a  
G2  
G2  
Blue or White-  
Orange  
Red-Pink  
Blue-White  
Gray-Yellow  
Gray-Brown  
n/a  
30-50 ohms  
30-50 ohms  
n/a  
G2  
G2  
G2  
G2  
3-4  
1-2  
7-5  
7-6  
n/a  
0-6 VDC  
0-6 VDC  
n/a  
Note: The grey wire listed above turns to black at F connector on the PCB.  
Table 13. (QS) Water Flow Sensor.  
Connector  
Pin  
Nos.  
Wire Color  
Voltage  
Resistance  
No.  
Black-Red  
11-13 VDC  
4-7 VDC  
n/a  
E5  
1-3  
2-3  
Yellow-Black  
1-1.4 Mega ohms  
E5  
Table 14. By-pass Flow Control.  
Connector  
No.  
Pin  
Nos.  
Wire Color  
Voltage  
Resistance  
Brown-White  
Orange-White  
Yellow-White  
G1  
G1  
G1  
1-5  
2-5  
3-5  
2-6 VDC (unit  
in operating  
mode)  
15-35 ohms  
Red-White -  
Ground  
G1  
4-5  
Table 15. (IG) Ignition System.  
Connector  
No.  
Pin  
Nos.  
1-2  
Wire Color  
Voltage  
90-110 VAC  
Resistance  
Grey-Grey  
n/a  
D1  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 16. (FM) Combustion Fan Motor.  
Connector  
No.  
Pin  
Nos.  
Wire Color  
Voltage  
Resistance  
Red-Black  
White-Black  
Yellow-Black  
6-45 VDC  
5-10 VDC  
11-13 VDC  
n/a  
L1  
L1  
L1  
1-2  
2-4  
2-3  
9.2-9.4k ohms  
3.5-3.9k ohms  
Set your meter to the hertz scale. Reading across the white and black wires at terminals 2 and 4 you should read  
between 60 and 420 hertz.  
Table 17. Thermal Fuse / Overheat Switch.  
Connector  
No.  
Pin  
Nos.  
Wire Color  
Voltage  
Resistance  
B1  
E1  
B13-  
E9  
Red-White  
11-13 VDC  
Below 1 ohms  
Flame Rod:  
Place one lead of your meter to the flame rod and the other to ground. With the unit running, you should  
read between 5-150 VAC. Set your meter to micro-amp scale and series your meter in line with the flame  
rod. You should read 1 micro-amp or greater for proper flame circuit. In the event of low flame circuit,  
remove the flame rod and check for carbon or damage.  
Heat Exchanger and Outgoing Water Temperature Thermistors:  
Check all Thermistors by inserting meter leads into each end of the thermistor plug. Set your meter to the  
20k scale and read resistance. Applying heat to the thermistor bulb should decrease the resistance.  
Applying ice to the thermistor bulb should increase the resistance. See below for examples of typical  
temperatures and resistance readings.  
Example:  
59ºF = 11.4-14kΩ  
86ºF = 6.4-7.8kΩ  
113º = 3.6-4.5kΩ  
140ºF = 2.2-2.7kΩ  
221ºF = 0.6-0.8kΩ  
Table 18. Outgoing Water Thermistor.  
Connector  
No.  
Pin  
Nos.  
Wire Color  
White-White  
Blue-Blue  
Voltage  
n/a  
Resistance  
See example  
above  
See example  
above  
E4  
E3  
E3-E4  
E6-E5  
n/a  
Table 19. Heat Exchanger Temperature Thermistor.  
Connector  
No.  
Pin  
Nos.  
Wire Color  
Voltage  
Resistance  
See example  
above  
Pink-Pink  
n/a  
E2  
5-10  
Table 20. Surge Protector.  
Connector  
No.  
Pin  
Nos.  
Wire Color  
Voltage  
Resistance  
Black-White  
White-White  
108-132 VAC  
108-132 VAC  
n/a  
n/a  
C2  
C1  
1-3  
1-3  
With the power off, you can check the continuity through the surge protector. Place a meter lead on the  
top pin #1 of the surge protector and pin #3 on the bottom of the surge protector. Check across the top  
pin #3 and the bottom pin #1. If you read continuity across these two points, the surge protector is good.  
If you do not get continuity, replace the surge protector.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 21. Remote Controls.  
Connector  
No.  
Pin  
Nos.  
Wire Color  
Voltage  
10-13 VDC  
Resistance  
Terminals A1  
1.5-3.0k ohms  
A
1-3  
Frost Protection:  
This unit has frost protection heaters mounted at different points to protect the water the water heater  
from freezing. The heaters located on the hot water outlet line should have a resistance reading of 10-20  
ohms through each of these heaters. The heater located on the heat exchanger piping should have a  
resistance reading of 35-50 ohms, and the one located in the water flow sensor valve, hot water outlet,  
and drain connection should have a resistance reading of 110-150 ohms. The heater located on the  
latent heat exchanger should have a resistance reading 90-110 ohms.  
Amp Fuses:  
This unit has one inline seven-amp glass fuses. Remove the fuse and check continuity through it. If you  
have continuity through the fuse, it is good. Otherwise, the fuse is blown and must be replaced.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION VII: OPERATING INSTRUCTIONS  
WARNING  
Water heaters are heat-producing appliances. To avoid damage or injury there must be no  
materials stored against the water heater or direct vent system, and proper care must be taken to  
avoid unnecessary contact (especially by children) with the water heater and direct vent system.  
UNDER NO CIRCUMSTANCES SHOULD FLAMMABLE MATERIALS, SUCH AS GASOLINE OR  
PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS WATER HEATER OR IN ANY  
LOCATION FROM WHICH FUMES COULD REACH THE WATER HEATER.  
Installation or service of this water heater requires ability equivalent to that of a licensed tradesman  
in the field involved. Plumbing, air supply, venting, gas supply, and electrical work are required.  
Light the unit in accordance with the operation instructions label attached to the water heater.  
Under no circumstances should the input rate exceed the input rate shown on the water heater  
rating plate. Over firing could result in damage or sooting of the water heater.  
If the unit is exposed to the following, do not operate water heater until all corrective steps have  
been made by a factory authorized independent service contractor or qualified service professional.  
1. Flooding to or above the level of the burner or controls  
2. External firing  
3. Damage  
4. Firing without water  
5. Sooting  
Never operate the water heater without first being certain it is filled with water and a pressure relief  
valve is installed in the HOT WATER OUTLET PIPING of the water heater.  
GENERAL INSTRUCTIONS  
TO FILL THE WATER HEATER  
1. Close the water heater drain valve by turning the knob or valve stem clockwise.  
2. Open the cold water supply shut-off valve.  
3. Open several hot water faucets to allow air to escape from the system.  
4. When a steady stream of water flows from the faucets, the water heater is filled. Close the  
faucets and check for water leaks at the water heater drain valve, pressure relief valve, and the  
hot and cold water connections.  
SEQUENCE OF OPERATION  
1. Water heater senses the minimum operating water flow which starts the ignition sequence to light  
the burners.  
2. Blower ON  
3. Gas valve opens and spark igniter starts.  
4. Main burner ON  
5. Flame signal confirmed  
6. Burner flame and combustion blower modulates to maintain selected outlet temperature  
7. Water flow is also regulated to not exceed the capacity of the water heater for the temperature  
selected.  
8. Water flow shuts off.  
9. Burners shut off immediately, but combustion blower continues for several seconds to purge heat  
from coil.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIGHTING INSTRUCTIONS  
FOR YOUR SAFETY READ BEFORE OPERATING  
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing  
property damage, personal injury or loss of life.  
A. This water heater does not have a  
pilot. It is equipped with a direct  
ignition device, which automatically  
lights the burner. Do not try to light  
the burner by hand.  
Immediately call your gas supplier from a  
neighbor’s phone. Follow the gas supplier’s  
instructions.  
If you cannot reach your gas supplier, call the fire  
department.  
B. BEFORE OPERATING: Smell all  
around the appliance area for gas.  
Be sure to smell next to the floor,  
because some gas is heavier than  
air and will settle on the floor.  
C. Use only your hand to operate the remote control  
keypad. Never use tools. If the remote keypad  
doesn’t work, do not try to repair it, call a qualified  
service technician. Forced or improper repair  
may result in a fire or explosion.  
WHAT TO DO IF YOU SMELL GAS  
D. Do not use this water heater if any part has been  
under water. Immediately call a qualified service  
technician to inspect the water heater and to  
replace any part of the control system and any  
gas control which has been under water.  
Do not try to light any appliance.  
Do not touch any electric switch; do  
not use any phone in your building.  
OPERATION INSTRUCTIONS  
1. STOP! Read the safety information  
above before proceeding.  
6. Wait (5) minutes to clear out any gas. If you  
then smell gas, STOP! Follow “B” in the safety  
information above on this label. If you don’t smell  
gas, go to next step.  
2. Set the thermostat to the lowest  
setting.  
7. Turn the manual valve located at the gas inlet of  
appliance counterclockwise  
Figure 15).  
to “ON” (See  
3. Turn off all power to the electrical  
appliance.  
8. Turn on all electric power to the appliance.  
4. This water heater does not have a  
pilot. It is equipped with a direct  
ignition device, which automatically  
lights the burner. Do not try to light  
the burner by hand.  
9. Set the thermostat to desired setting.  
10. If the appliance will not operate, Follow the  
instructions “To Turn Off Gas To Appliance” and  
call your service technician or gas supplier.  
5. Turn the manual valve located at the  
gas inlet of the appliance clockwise  
to “OFF” (See Figure 15).  
TO TURN OFF GAS TO THE APPLIANCE  
1. Set the thermostat to the lowest  
setting.  
3. Turn the manual valve at gas inlet of appliance  
clockwise  
to “OFF” (See Figure 15).  
2. Turn off all electric power to the  
appliance if service is to be  
performed.  
Figure 15. Manual Gas Valve.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
In climates where below freezing temperatures may occur, the water heater must be drained when  
power is off to the water heater to prevent freeze damage to the heat exchanger. Drain solenoids  
are recommended to prevent freeze damage during power failures in cold climate regions.  
TURNING OFF THE WATER HEATER FOR AN EXTENDED PERIOD OF TIME  
If the EverHotwater heater is to be turned off for an extended period of time, the following steps should  
be taken.  
1. Turn the gas shutoff valve on the gas supply inlet to the OFF position (See Figure 15).  
2. Disconnect the electrical supply to the water heater.  
3. Shut off the cold water supply to the water heater and open the drain valve to drain the water  
heater. If the water heater was installed with drain solenoid freeze protection, the water  
heater will drain automatically when power is disconnected.  
TEMPERATURE ADJUSTMENT  
DANGER  
Hotter water increases the risk of scald injury. Scalding may occur within 5 seconds at a  
temperature setting of 140F (60C). To protect against hot water injury, install a mixing valve in the  
water system. This valve will reduce point of discharge temperature by mixing cold and hot water in  
branch water lines. A licensed plumbing professional or local plumbing authority should be  
consulted.  
CAUTION  
This water heater, when set at a lower temperature setting is not capable of producing hot water of  
sufficient temperature for sanitizing purposes. Always check water temperature by hand before  
entering the shower or bath. The temperature may have been changed.  
NOTICE  
This water heater is equipped with an energy cut out device to prevent overheating. Should  
overheating occur or the gas supply fails to shut off, turn off the manual gas control valve to the  
water heater and call a qualified service agent.  
NOTICE  
The lower the temperature setting, the greater the energy efficiency to heat the water. Lower water  
temperatures also extend the heat exchanger life. Remember, no water heating system will provide  
exact temperatures at all times. Allow a few days of operation at this setting to determine the correct  
temperature setting consistent with the requirements for the installation.  
1. The outlet water temperature of the EverHot water heaters is adjusted using the main remote  
control (or optional remote controls). When a remote temperature control is installed, the  
temperature can only be adjusted on the control that has the Priority Indicator Light glowing.  
The temperature displayed on the control in use will also be displayed on all the other remote  
controls.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. To set the desired temperature on the control, all hot water faucets must be closed. If there  
are more remote controls installed, press the “Priority” button on the control you want to  
change the setting on and the “Priority” indicator light will glow.  
3. Press the “Up” or “Down” button until the required temperature is displayed on the digital  
monitor. The default available water temperature range for the main control is 98-120ºF.  
4. To operate the water heater, simply turn any hot water tap on. This will automatically light the  
burner and provide hot water at the preset temperature. If the optional remote controls have  
been installed, the “IN USE” indicator light will glow on all remote controls.  
5. The control(s) can also display diagnostic codes, water flow rate through the unit (in gallons  
per minute) and the outlet water temperature.  
6. Press and hold the “On/Off” button for 2 seconds. While holding the “On/Off” button, press  
the “Up” button to display a sequence of up to 9 diagnostic codes, if any, stored in memory  
that has been experienced. Any diagnostic codes will be displayed on the digital monitor in  
sequence starting with the most recent code. To exit this mode, press the “On/Off” button  
and “Up” button as before.  
7. Press and hold the “Up” button for 2 seconds and without releasing, press the “On/Off” to  
display the water flow through the water heater with hot water in use (GPM = Display  
Readout X 0.1).  
8. Press and hold the “Down” button for 2 seconds and without releasing, press the “On/Off” to  
display the outlet water temperature while in use (degrees F).  
In Use Indicator  
Temperature Display  
Priority Button  
Priority Indicator  
Figure 16. Remote Control and the Description of Functions on All Controls.  
NOTICE  
The temperature can only be adjusted between 98F and 110F when the hot water tap is open and  
hot water is flowing. This is a safety feature to prevent scalding while hot water is in use.  
NOTICE  
The default temperature setting that will appear when the water heater is first connected to the  
electrical supply is 104ºF. In the event of a power interruption, the unit will retain its set temperature  
for up to 6 hours. If the power is interrupted for more than 6 hours, the unit will revert back to a  
temperature of 104°F.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCALDING  
Figure 17. Scalding Warning.  
This water heater can deliver scalding temperature water at any faucet in the system. Be careful  
whenever using hot water to avoid scalding injury. Certain appliances, such as dishwashers and  
automatic clothes washers may require increased water temperature. By setting the thermostat on this  
water heater to obtain the increased temperature water required by these appliances, you may create the  
potential for scald injury. To protect against injury, you should install a tempering valve in the water  
system. This valve will reduce point of discharge temperature by mixing cold and hot water in branch  
supply lines. Such valves are available from the local plumbing supplier.  
CAUTION  
Test the temperature of the water with your elbow before placing a child in the bath or shower. Do not  
leave a child or an infirm person in the bath unsupervised.  
The following chart details the relationship of water temperature and time with regard to scald injury and  
may be used as a guide in determining the safest water temperature for your applications.  
Table 22. Relationship Between Exposure to Hot Water and When a Scald Results.  
APPROXIMATE TIME/TEMPERATURE  
RELATIONSHIPS IN SCALDS  
More than 5 minutes  
120°F (49C)  
125°F (52C)  
130°F (54C)  
135°F (57C)  
140°F (60C)  
145°F (63C)  
150°F (66C)  
155°F (68C)  
1½ to 2 minutes  
About 30 seconds  
About 10 seconds  
Less than 5 seconds  
Less than 3 seconds  
About 1½ seconds  
About 1 second  
FIRST AID FOR SCALDS  
1. Apply cold water to burned area for 30 minutes to reduce the heat in the skin and prevent deeper  
burning. Never use butter, oils, or ointment to cover the burn. They may retain the heat.  
2. Use a blanket to keep the scalded person warm.  
3. Seek medical advice.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIAGNOSTIC CODES ON THE TEMPERATURE CONTROL DISPLAY  
The Bradford White EverHottankless water heaters have the ability to monitor and display any operating  
faults on the control display. The diagnostic codes will display on the monitor and will assist in servicing  
the water heater. The following is a listing of the diagnostic codes, which may flash on the monitor in  
case of a malfunction with the water heater. Please quote the code displayed when calling for service.  
Code  
03  
Code Description  
Remedy  
Power interruption  
during Bath Fill (Water  
will not flow when  
power returns).  
Turn off all hot water taps. Press ON/OFF twice.  
10  
Air Supply or Exhaust  
Blockage  
Ensure Bradford White approved venting materials are being used.  
Check that nothing is blocking the flue inlet or exhaust.  
Check all vent components for proper connections.  
Ensure vent length is within limits.  
Ensure condensation collar was installed correctly.  
Verify dip switches are set properly.  
Check fan for blockage.  
Burner Sensor Error (see code 31)  
Check the fins in the heat exchanger.  
11  
No Ignition  
Check that the gas is turned on at the water heater, gas meter, or cylinder.  
Ensure gas type and pressure is correct.  
Ensure gas line, meter, and/or regulator is sized properly.  
Bleed all air from gas lines.  
Verify dip switches are set properly.  
Ensure water heater is properly grounded.  
Disconnect Manifold Electronic Controls to isolate the problem.  
Ensure igniter is operational.  
Check igniter wiring harness for damage.  
Check gas solenoid valves for open or short circuits.  
Remove burner cover and ensure all burners are properly seated.  
Remove burner plate and inspect burner surface for condensation or debris.  
12  
Flame Failure  
Check that the gas is turned on at the water heater and gas meter. Check for  
obstructions in the flue outlet.  
Ensure gas line, meter, and/or regulator is sized properly.  
Ensure gas type and pressure is correct.  
Bleed all air from gas lines.  
Ensure proper Bradford White venting material was installed.  
Ensure condensation collar was installed properly.  
Ensure vent length is within limits.  
Verify dip switches are set properly.  
Ensure water heater is properly grounded.  
Disconnect keypad.  
Disconnect Manifold Electronic Controls to isolate the problem.  
Check power supply for loose connections.  
Check power supply for proper voltage and voltage drops.  
Ensure flame rod wire is connected.  
Check flame rod for carbon build-up.  
Disconnect and reconnect all wiring harnesses on unit and PC board.  
Check for DC shorts at components.  
Check gas solenoid valves for open or short circuits.  
Remove burner plate and inspect burner surface for condensation or debris.  
Check the ground wire for the PC board.  
14  
Thermal Fuse  
Check gas type of unit and ensure it matches gas type being used.  
Check for restrictions in air flow around unit and vent terminal.  
Check for low water flow in a circulating system causing short-cycling.  
Ensure dip switches are set to the proper position.  
Check for foreign materials in combustion chamber and/or exhaust piping.  
Check heat exchanger for cracks and/or separations.  
Check heat exchanger surface for hot spots which indicate blockage due to scale build-  
up. Refer to instructions in manual for flushing heat exchanger.  
Measure resistance of safety circuit.  
Ensure high fire and low fire manifold pressure is correct.  
Check for improper conversion of product.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Code  
16  
Code Description  
Remedy  
Over Temperature  
Warning  
Check for restrictions in air flow around unit and vent terminal.  
Check for low water flow in a circulating system causing short-cycling.  
Check for foreign materials in combustion chamber and/or exhaust piping.  
Check for clogged heat exchanger.  
25  
31  
32  
33  
Condensate Trap  
Error  
Condensate container is full.  
Check condensate drain for blockage.  
Replace condensate trap.  
Burner Sensor Error  
Measure resistance of sensor.  
Replace sensor.  
Outgoing Water  
Temperature Sensor  
Fault  
Check sensor wiring for damage.  
Measure resistance of sensor.  
Clean sensor of scale build-up.  
Replace sensor.  
Heat Exchanger  
Check sensor wiring for damage.  
Outgoing Temperature Measure resistance of sensor.  
Sensor Fault  
Clean sensor of scale build-up.  
Replace sensor.  
52  
61  
Modulating Solenoid  
Valve Signal Abnormal Measure resistance of valve coil.  
Combustion Fan  
Failure  
Check modulating gas solenoid valve wiring harness for loose or damaged terminals.  
Ensure fan will turn freely.  
Check wiring harness to motor for damaged and/or loose connections.  
Measure resistance of motor winding.  
65  
71  
72  
Water Flow Control  
Fault  
The water flow control valve has failed to close during the bath fill function. Immediately  
turn off the water and discontinue the bath fill function. Contact a state qualified or  
licensed contractor to service the water heater.  
SV0, SV1, SV2, and  
SV3 Solenoid Valve  
Circuit Fault  
Replace the PC board.  
Flame Sensing Device Ensure flame rod is touching flame when unit fires.  
Fault  
Check all wiring to flame rod for damage.  
Remove flame rod and check for carbon build-up; clean with sand paper.  
Check inside burner chamber for any foreign material blocking flame at flame rod.  
Measure micro amp output of sensor circuit with flame present.  
Replace flame rod.  
73  
Burner Sensor Circuit  
Error  
Check sensor wiring and PC board for damage.  
Replace sensor.  
LC  
Scale Build-up in Heat  
Exchanger (when  
Flush heat exchanger. Refer to instructions in manual.  
Replace heat exchanger.  
checking maintenance NOTE: The LC code is the only error code that will allow the unit to keep running. The  
code history, “00” is  
substituted for “LC”)  
display will alternate between the LC code and the temperature setting. The controller  
will continue to beep. The LC code will reset if power is turned off and then on.  
No  
code  
Nothing happens  
when water flow is  
activated.  
Clean inlet water supply filter.  
On new installations ensure hot and cold water lines are not reversed.  
Check for bleed over. Isolate unit from building by turning off hot water line to building.  
Isolate the circulating system if present. Open your pressure relief valve; if water is  
flowing, there is bleed over in your plumbing.  
Ensure you have at least the minimum flow rate required to fire unit.  
Ensure turbine spins freely.  
Measure the resistance of the water flow control sensor.  
Check for DC shorts at components.  
If any of the above diagnostic codes are seen flashing on the display, call for service.  
WARNING  
Failure to remedy faults may result in severe burns, scalds, and/or death.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION VIII: MAINTENANCE  
WARNING  
Always turn off the electrical power supply, the manual gas valve, and the manual water control  
valve whenever servicing this appliance.  
KEEP THE WATER HEATER AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS,  
GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS.  
The EverHotwater heater should be checked annually by a qualified technician. Regular maintenance  
will keep the water heater operating efficiently and help to assure reliable operation and a long service  
life.  
1. Remove and clean the inlet water filter screen. If a Y-type strainer or cartridge filter is used on  
the cold water inlet to the water heater, inspect or clean as needed to assure full water flow to the  
water heater.  
2. Visually inspect the burner flames. The flame must burn with a clear blue, stable flame (possibly  
with orange tips). Refer to Figure 18 for satisfactory flame appearance. If the burner flame  
appearance is not satisfactory or debris is visible on the burners, remove and clean with a  
vacuum cleaner.  
Figure 18. Burner Flame Appearance.  
3. Check the front vent outlet for blockage and clean, if necessary. Keep shrubs and vegetation  
clear of the vent terminal.  
4. All electric motors are permanently lubricated and do not need oiling. Remove the combustion air  
blower and clean wheel and housing with soft brush or vacuum.  
5. If the “LC” code has been flashing on the display, the heat exchanger will need flushing to remove  
lime and scale deposits. Refer to the “Flushing Procedure for Lime Scale Removal…” in Section  
VIII, “Maintenance.”  
6. Check operation of the pressure relief valve. To check the relief valve, lift the lever at the end of  
the valve several times. The valve should seat properly and operate freely. If water does not  
flow, remove and inspect for obstructions or corrosion. Replace with a new valve of the  
recommended size as necessary. A thorough inspection of the valve should be performed at  
least every three years by removing the pressure relief valve from the outlet piping. Do not  
attempt to repair the valve, as this could result in improper operation and explosion of the heat  
exchanger and piping. In areas with poor water conditions, it may be necessary to inspect the  
pressure relief valve more often than the recommended maintenance schedule.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
Before manually operating the valve, make sure that a drain line has been attached to the valve to  
direct the discharge to an open drain. Failure to take this precaution could mean contact with  
extremely hot water passing out the valve during this checking operation.  
FLUSHING PROCEDURE FOR MINERAL SCALE REMOVAL FROM HEAT EXCHANGER  
The amount of calcium carbonate (minerals) released from water is in direct proportion to water  
temperature and usage. The higher the water temperature or water usage and the harder the water  
(more dissolved calcium carbonate), the more mineral deposits are dropped out of the water. This is the  
mineral scale that forms in pipes, water heaters, and on cooking utensils.  
Mineral accumulation reduces the efficiency and longevity of the heat exchanger coil and will cause the  
water heater to malfunction. The mineral scale may need to be periodically removed from the heat  
exchanger (indicated by the “LC” code on the remote display). The usage of water softening equipment  
greatly reduces the hardness of the water. However, this equipment does not always remove all of the  
hardness (minerals). The heat exchanger may occasionally need to be flushed to clear out the mineral  
deposits. Use the following procedure and Figure 19 to flush the heat exchanger and remove the mineral  
scale.  
1. Disconnect power to the water heater.  
2. Close the shut-off valves in the cold water inlet and outlet supply (V3 and V4).  
3. Connect pump outlet hose (H1) to the cold water line at valve (V2). Connect drain hose (H3) to  
valve (V1).  
4. Pour 4 gallons of virgin, food grade, white vinegar or citric acid into a 5 gallon bucket.  
5. Place the drain hose (H3) and the hose (H2) to the pump inlet into the cleaning solution.  
6. Open the both valves (V1 and V2) to the hot and cold water lines.  
7. Turn on power to the circulating pump and allow the vinegar to circulate through the heat  
exchanger coil for at least 45 minutes. Heat exchangers containing a considerable amount of  
minerals may require several hours.  
8. Turn off power to the circulating pump.  
9. Remove the free end of the drain hose (H3) from the pail and route it to a drain.  
10. Close the valve (V2) and open shut-off valve (V4). Do not open shut-off valve (V3).  
11. Allow water to flow out of the hose for 5 minutes to flush vinegar from the water heater.  
12. Close service valve (V1) and open shut-off valve (V3).  
13. Disconnect the hoses from the valve connections.  
14. With (V4) closed, remove the in-line filter at the cold water inlet and clean out any residue. Place  
the filter back into unit and open (V4).  
15. Restore power to the water heater and check operation.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EverHot®  
Water Heater  
In-line  
Filter  
Gas Supply  
V2  
V1  
H3  
V4  
V3  
Cold Water Line  
Hot Water Line  
H2  
H1  
5 gallon pail of virgin, food  
grade, white vinegar (or virgin,  
food grade, citric acid).  
Circulating Pump  
Figure 19. Piping for Mineral Scale Flushing.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Common Troubleshooting Comments on the Operation of the EverHot® Tankless Water Heater  
Comment: I don’t have any hot water when I open the tap!  
Make sure the gas and electricity is turned on to the water heater. The temperature display should have  
the green light lit when a hot water tap is open and the water heater is operating. Make sure there are no  
diagnostic codes flashing on the display.  
Comment: When I was using the hot water, the water got cold!  
If you reduced the hot water flow from the tap, you may have reduced the flow below the minimum flow to  
operate the water heater. If you mix the hot water with cold water at the tap in an attempt to get a  
temperature below the temperature being produced by the water heater, the hot water flow through the  
water heater may drop below the minimum flow required to operate the water heater. To remedy this  
situation, either increase the total water flow from the tap or using the control, decrease the setpoint  
temperature of the water heater to the temperature desired at the tap.  
Comment: White smoke comes out of the exhaust!  
During colder weather when the exhaust temperature is much hotter than the ambient air, the moist  
exhaust gases condense producing a white vapor cloud.  
Comment: When I open a hot water faucet I do not immediately get hot water!  
Hot water must travel through the plumbing piping to the faucet. This may take from 10 to 30 seconds  
depending upon the length of cold plumbing pipe the water must travel through.  
Comment: After I turn off the hot water tap, the fan on the water heater continues to run!  
The fan is designed to continue to run for a short period of time after the flow of water stops. This is to  
ensure constant water temperature during frequent short water draws (such as washing dishes), as well  
as exhausting residual heat and flue gases from the water heater and venting system.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION IX: PARTS LIST  
TGHE-160E and TGHE-199E Models  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TGHE-160E TGHE-199E  
Quantity  
No.  
Description  
001 Main Body  
002 Wall Bracket  
003 Rubber Bushing  
004 Connection Reinforcement Panel  
005 Heat Protection Plate  
006 Front Panel  
007 Gasket - Top and Bottom  
008 Gasket - Side  
011 Screw Cover  
012 Screw Cover Lid  
013 Cable Access Assembly  
014 Rubber Bushing  
016 Packing  
017 Screw Cover Assembly  
021 Reinforcement Bracket  
022 Attachment Bracket  
801 Screw  
1
2
1
1
1
1
2
2
2
4
1
1
1
2
1
3
4
4
1
2
1
1
1
1
2
2
2
4
1
1
1
2
1
3
4
4
802 Washer  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TGHE-160E  
TGHE-199E  
No.  
Description  
Quantity  
103 Burner Unit Assembly LPG  
Burner Unit Assembly NG  
104 Burner Case Cover  
106 Burner Packing  
107 Burner  
1
1
-
-
-
1
1
1
1
16  
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
6
2
4
1
1
2
3
4
2
108 Burner Case Back Cover  
109 Damper LPG  
-
1
1
1
1
-
Damper NG  
110 Manifold Assembly NG  
Manifold Assembly LPG  
111 Manifold Packing  
112 Manifold Packing  
114 Combustion Chamber Sight Glass Plate  
116 Electrode  
-
1
1
2
1
1
-
1
-
-
117 Flame Rod  
118 Electrode Packing  
119 Electrode Holder  
120 Chamber Packing  
125 Fan Motor All Assembly  
126 Fan Casing  
127 Fan Inlet Connector  
128 Fan Inlet Packing  
135 Air Inlet Box All Assembly  
137 Flue Outlet Packing  
138 Seal Packing  
143 Heat Exchanger Assembly  
151 Burner Fixing  
160 Heat Exchanger Secondary  
166 Reinforcement Bracket  
423 Clip  
424 Connecting Pipe  
431 Connecting Pipe - Inlet  
432 Connecting Pipe - HEX  
433 Clip  
434 Clip  
706 Ignitor  
707 High Tension Cord  
708 Electrode Sleeve  
709 Thermistor  
710 Thermistor Clip Large  
711 Thermal Fuse Clip  
716 Anti-Frost Heater Clip B  
718 Anti-Frost Heater Clip C  
728 Ignitor Attachment Plate  
806 Screw  
-
1
1
1
1
-
-
1
1
1
1
1
2
1
1
1
1
1
1
5
2
1
1
1
2
3
4
2
810 O-ring  
814 O-ring  
815 O-ring  
824 O-ring  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TGHE-160E  
TGHE-199E  
No.  
Description  
Quantity  
100 Gas Controller Assembly  
101 Test Port Set Screw  
102 Gas Connection 3/4" NPT  
400 Water Inlet 3/4" NPT  
401 Water Flow Servo and Sensor Assembly  
402 Rectifier  
403 By-pass Flow Assembly  
404 Stop Bracket  
408 Hot Water Outlet 3/4" NPT  
409 Stop Bracket  
410 Plug Band (Small)  
411 Drain Valve  
412 Water Filter Assembly  
413 Cover  
421 Drain Connection  
422 Drain Plug  
423 Clip  
426 Packing  
440 Condensate Trap  
441 Packing  
442 Condensate Trap Plug  
446 Screw  
447 Connection Harness  
700 PC Board  
701 Surge Protector  
701 Surge Protector with Terminals  
702 PC Board Cover Side  
703 PC Board Cover Front  
704 Clip  
712 Frost Sensing Switch  
727 Flow Sensor  
730 Thermistor  
743 Secondary Heat Exchanger Heater  
744 Heater and Harness  
803 Screw  
804 Screw  
806 Screw  
807 Washer  
810 O-ring  
813 O-ring  
814 O-ring  
816 O-ring  
817 O-ring  
818 Packing  
819 Screw  
820 Screw  
821 Screw  
822 Screw  
823 O-ring  
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
2
1
2
1
1
1
-
1
1
1
1
1
1
1
-
3
1
1
2
2
3
3
1
1
1
2
4
2
3
1
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
2
1
2
1
1
1
1
1
1
1
2
1
1
-
1
3
1
1
2
2
1
3
1
1
2
2
4
2
3
1
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TGHE-160E  
TGHE-199E  
No.  
Description  
Quantity  
447 Connection Harness  
712 Frost Sensing Switch  
713 Anti-Frost Heater 120V  
715 Valve Heater 120V Assembly  
721 Fuse Harness  
1
1
1
1
1
1
1
1
1
1
1
1
1
-
1
2
1
1
1
1
1
1
1
1
1
1
1
1
722 Power Harness  
724 Sensor Harness  
725 Thermal Fuse Harness Assembly  
726 Ignitor Harness  
729 Temperature Controller Harness  
731 Solenoid Connection Harness  
732 AWG#18 Harness  
733 Connection Harness  
744 Heater and Harness  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION X: WARRANTY  
What does this Limited Warranty Cover?  
This limited warranty covers both the heat exchanger and component parts for leakage or other  
malfunction caused by defects in materials and/or workmanship. It applies to the original consumer  
purchaser and to any subsequent owner as long as the water heater remains installed at its original place  
of installation.  
What does this limited warranty not cover?  
This limited warranty does not cover leakage or other malfunction caused by:  
a) Defective installation, reinstallation at another location and specifically, any installation which is  
made in violation of applicable state or local plumbing, housing or building codes, or without a  
certified American Gas Association, ASME, or comparable combination temperature and  
pressure relief valve, or contrary to the written instructions furnished with the unit.  
b) Adverse local conditions, and specifically sediment or lime precipitate in the heat exchanger;  
corrosive elements in the atmosphere; or water quality contrary to the written requirements  
furnished with the unit.  
c) Misuse, and specifically operations and/or maintenance contrary to the written instructions  
furnished with the unit, removal of anode(s), disconnection, alteration or addition on non-  
approved components or apparatus, operation at settings other than those set forth on the rating  
plate, or accidental or other exterior damage.  
This warranty also does not cover:  
a) Production of noise, taste, odors, discoloration or rusty water.  
b) Incidental property damage, loss of use, inconvenience or other incidental or consequential costs.  
c) Costs associated with the replacement and/or repair of the unit, including any freight, shipping or  
delivery charges, any removal, installation or re-installation charges, any material, and/or permits  
required for installation, re-installation or repair, or charges to return the defective heater and/or  
component part to the manufacturer.  
What is the duration of the implied warranty?  
Any implied warranties, including the warranty of merchantability imposed on the sale of the water heater  
under the laws of the state of sale are limited in duration to one year from date of original installation.  
How does state law relate to the warranty?  
Some states do not allow:  
a) Limitations on how long an implied warranty lasts.  
b) Limitations on incidental or consequential damages.  
So the above limitations or exclusions may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights which vary from state to  
state.  
What is the period of coverage?  
This limited warranty runs from the date of installation (or without proof of installation, from three (3)  
months after the date of manufacture) for the period specified on the following chart.  
Item  
Residential  
Applications  
Commercial and Radiant Heating  
Applications  
Heat Exchanger  
All other Parts and Components  
12-years*#  
5-years*#  
5-years*  
5-years*  
A warranty product or part is provided exclusive of labor, freight, and/or any installation costs. All  
replacement heaters and parts carry the balance of the original warranty, i.e. if an original twelve (12)  
year warranted heater develops a leak due to defects in materials/workmanship after only ten (10) years,  
the replacement unit is warranted for two (2) years in this example.  
*Note: Period of coverage is reduced to 3-years from date of purchase when used as a circulating water  
heater within a hot water circulation loop, where the water heater is in series with a circulation system and  
all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
demand recirculation is not incorporated. A system that incorporates a continuous recirculation due to  
timer settings, excessive heat loss of the loop or aquastat / thermostat setting will be treated as a  
continuous circulation system and have a reduced warranty of 3 years.  
On-demand recirculation is defined as a hot water re-circulating loop or system that utilizes existing hot  
and cold lines or a dedicated return line, and only activates when hot water is used. It can be activated  
by a push button, motion sensor, or voice activation but not by a temperature sensor. A timer added to a  
standard re-circulating pump is not considered as on-demand.  
# The warranty for a heat exchanger used in a circulation system which is controlled through an aquastat  
/ thermostat, or timer, or an on-demand system is 12 years for residential applications.  
Use of a Main Controller/Commercial control (p/n 239-48789-00) in a residential dwelling will reduce the  
warranty coverage to that of a commercial warranty application.  
What will we do to correct problems?  
If a defect occurs within the heat exchanger warranty period, we will:  
a) Provide a replacement water heater of our manufacture, (or at our option) repair any unit which  
develops a leak in the heat exchanger with the warranty period. To obtain a replacement water  
heater, you must forward both the rating plate from the defective unit to us and a copy of the  
original sales receipt. If government regulations require the replacement heater to have features  
not found in the defective heater, you will be required to pay the difference in price represented  
by those government required features.  
If a defect occurs within the parts warranty period, we will:  
a) Provide a replacement part (or at our option repair) any part which fails to function within the parts  
warranty period. To obtain a replacement, you must forward the defective part to us. If  
government regulations require the replacement part to have features not found in the defective  
part, you will be required to pay the difference in price represented by those government required  
features.  
What will we not do?  
We will not:  
a) Repair or replace any water heater, or part, subject to conditions outlined in “What does this  
limited warranty not cover?”  
b) Reimburse any costs associated with repair and/or replacement.  
c) Replace and/or repair any heater without complete model/serial number.  
d) Replace any water heater without prior receipt of actual rating plate from appliance and copy of  
original sales receipt.  
How do you get warranty assistance?  
Upon discovering s defect or problem, you should  
a) Contact either the installer or dealer, or  
b) Contact us  
Bradford White Corporation  
Warranty Support Group  
200 Lafayette Street  
Middleville, MI 49333  
1-800-531-2111  
What should you do to keep the warranty in effect?  
To facilitate warranty assistance, you should:  
a) Follow all instructions enclosed with the product.  
b) Retain all bills of sale or receipts for proof of installation, etc.  
c) Contact your installer, dealer or our Warranty Department as soon as any problem or defect is  
noticed.  
d) When necessary, allow us, or our chosen representative, to inspect the unit.  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EverHot® Limited Warranty Registration  
In order to confirm Limited Warranty coverage at 12 years for Residential Applications1,  
complete the information below and click submit.  
*Consumers First Name:  
____________________  
*Address:  
*Consumers Last Name:  
___________________  
*City:  
____________________  
*State:  
____________________  
*Zip:  
____________________  
*Phone Number:  
____________________  
*Installation Date:  
____________________  
*Purchase Date:  
____________________  
*Installation Application Type:  
(Ex: Residential or Commercial)  
____________________  
*Model Number:  
____________________  
*Serial Number:  
____________________  
____________________  
*Installation Company:  
(Ex: ABC Plumbing Company)  
Installer’s EverHot® Certification Number:  
(Ex: 109456)  
____________________  
Installer’s Phone Number:  
____________________  
*Denotes required fields  
____________________  
(1) Period of coverage is reduced to the Commercial Applications Limited Warranty (see  
above box) if above information is not received by Bradford White Corporation.  
Fax Number: Warranty Support Group: 269-795-1089  
Mail: Warranty Support Group: 200 Lafayette Street, Middleville, MI 49333-9493  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ambler, PA  
For U.S. and Canada field service,  
Contact your professional installer or  
local Bradford White representative.  
Sales/800-523-2931  
Fax/215-641-1670  
Parts Fax/215-641-2180  
Technical Support/800-334-3393  
Fax/269-795-1089  
Warranty/800-531-2111  
Fax/269-795-1089  
International:  
Telephone/215-641-9400  
Telefax/215-641-9750  
Mississauga, ON  
Sales/866-690-0961  
905-238-0100  
Fax/905-238-0105  
Technical Support/800-334-3393  
Email  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Switch LE2425A User Manual
Blue Rhino Charcoal Grill 253341 User Manual
Bolens Lawn Mower 13000 User Manual
Brother All in One Printer DCP 117C User Manual
Cabletron Systems Switch HSIM A6DP User Manual
Canon All in One Printer 3480i User Manual
Chamberlain Garage Door Opener 2245 User Manual
Channel Vision Network Card IR 2005 User Manual
Chromalox Fan ESFS 40 User Manual
Cisco Systems IP Phone 7925G EX User Manual