Bradford White Corp Water Heater Electric Instantaneous Water Heaters User Manual

Electric Instantaneous Water Heaters  
®
The KwickShot Electric Instantaneous Water Heaters  
Models Feature:  
I On Demand Hot Water—No delay.  
I Reduced Energy Waste—Flow switch activates heater only  
on demand (no stand-by heat loss). 99% efficient.  
I Continuous Hot Water—No storage capacity to run out.  
I No Need for a T&P Relief Valve—Check local codes.  
I Integral Flow Restrictor—Built-in to ensure proper  
temperature rise.  
I Prevention Of Bacteria Growth.  
I Easy Installation—Mounts on wall – no sweat connections.  
I Ni Chrome Heating Element—A unique, patented flow  
path ensures optimum heat transfer and extended  
element life.  
I Durable Design—Reduces calcification and sedimentation.  
I Space Saving Installation—Compact size.  
I High Temperature Limit Switch (ECO)—Protects against  
element burn out, with reset button.  
I Warranty—Heaters are designed for durability and  
guaranteed against failure due to leaks of Heater  
Body/Element Assembly for a period of 10 years. Field  
serviceable element with replaceable cartridge element (1  
year warranty).  
I Single Phase and Three Phase models—Single Phase  
models 240 volt and below are cUL certified.  
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties.  
See complete copy of the warranty included with the heater.  
LISTED  
WHERE  
APPLICABLE  
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171;  
(B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534;  
7,270,087 B2. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271.  
KwickShot® is a registered trademark of Bradford White® Corporation.  
217-B-1108-A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electric Instantaneous Water Heaters  
Turn on 0.5 GPM (up to 6.5kW)  
Turn on 0.7 GPM (7.5 kW and up)  
Max Flow 2.0 GPM  
Flow Controlled (Single Phase)  
Model  
kW  
Temperature Rise °F  
0.75 1.0 1.5 2.0  
GPM GPM GPM GPM GPM  
Recommended  
Wire Size  
Voltage AMPS  
Please consult local codes for electrical requirements. Additional  
voltages and wattages are available. For more information please  
consult factory.  
Number  
Rating  
0.5  
EFC-5500-4-S-10 5.5  
EFC-6500-4-S-10 6.5  
EFC-7500-4-S-10 7.5  
EFC-9500-4-S-10 9.5  
EFC-8300-2-S-10 8.3  
240  
240  
240  
240  
208  
23.0  
27.0  
32.0  
40.0  
39.0  
75  
88  
50  
59  
68  
86  
76  
38  
44  
51  
65  
57  
25  
30  
34  
43  
38  
18  
22  
25  
32  
29  
10 AWG  
10 AWG  
8 AWG  
8 AWG  
8 AWG  
Refer to Voltage Identification Code Chart on page 5.  
Applications: Single Phase Only.  
Kitchen Sinks, Bar Sinks, Dual Lavs, Utility Sinks, Manufacturing  
Facilities, and Modular Buildings.  
Specifications:  
Dimensions: 1034" x 514" x 27⁄  
Weight: 3 lbs.  
27  
8
8"  
"
51  
4
"
Materials:  
Cover: ABS UL rated 94Vo.  
Glass reinforced “UDEL†” Heater Body  
and Ni Chrome Element  
Color: White  
Standard temperature range  
100°F-140°F.  
Maintains accurate temperature control  
1°F  
Element: Replaceable cartridge insert  
Pipe-Fittings: 1/2" NPT compression at  
bottom of unit.  
93  
4
"
103  
4
"
Operating Pressure: Min 25 PSI,  
Max 150 PSI.  
OUTLET  
INTLET  
3
11  
2
"
"
4
Activated in stages based on demand  
Min. flow 0.7 GPM Max Flow 3.0 GPM  
Series Two - Thermostatic (Single Phase)  
(Twin Module) With Single Thermostatic Control  
Model  
kW  
Temperature Rise °F  
1.5 2.0 2.5 3.0  
GPM GPM GPM GPM  
87 65 52 43  
Recommended  
Wire Size  
Please consult local codes for electrical requirements.  
Additional voltages and wattages are available. For  
more information please consult factory.  
Voltage  
AMPS  
Number  
Rating  
EFT-19000-4-D-10 19.0  
240  
80 (2 x 40 Amps)  
8 AWG per module  
Refer to Voltage Identification Code Chart  
on page 5.  
The unit must have 2 independent electrical circuits using correctly rated wire  
and 2 circuit breakers.  
Applications: Single Phase Only.  
Residential-Single Shower (Cabin or Condo), Multi Lavs.  
SPEC OPTIONS:  
Multi Lavs = ML 0.5 turn on  
set temp.  
9"  
Set Temp = 105°F.  
Specifications:  
Dimensions: 10" x 9" x 3"  
Weight: 8 lbs.  
Materials:  
Cover: Enameled Steel.  
Glass reinforced “UDEL†” Heater  
Body and Ni Chrome Element  
Color: White  
10"  
Element: Dual replaceable  
cartridge inserts  
Pipe-Fittings: 3/4" NPT pipe  
fittings at the bottom of the unit.  
Operating Pressure: Min 25 PSI,  
Max 150 PSI.  
"
4
3"  
ELECTRICAL  
SUPPLY  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electric Instantaneous Water Heaters  
Series Three (Single Phase)  
Min Flow 0.7 GPM  
Max Flow 4.0 GPM  
Please consult local codes for electrical requirements.  
Additional voltages and wattages are available. For  
more information please consult factory.  
Model  
kW  
Temperature Rise °F  
2.0 2.5 3.0  
GPM GPM GPM GPM GPM  
65 50  
Recommended  
Wire Size  
Voltage  
Current  
Per  
Number  
Rating  
1.5  
4.0  
Phase  
EFT-28000-4-T-10 28.0  
240  
120 (3x40 Amps)  
8 AWG  
Refer to Voltage Identification Code Chart  
on page 5.  
The unit must have 3 independent electrical circuits using correctly rated wire  
and 3 circuit breakers. This unit can only be ordered with 240V, but can be  
used on 208V with 25% reduced output (no model number change required).  
Applications: Single Phase Only.  
Whole House Residential up to 4.5 GPM (Apartment,  
Condo, Cabin).  
1
"
Specifications:  
15 4  
Dimensions: 1514"x 1214"x 41⁄  
Weight: 12 lbs.  
4"  
Materials:  
Cover: Enameled Steel.  
Glass reinforced “UDEL†”  
Heater Body and Ni Chrome  
Element  
Color: White  
Element: Three replaceable  
cartridge inserts  
1
"
12 4  
Pipe-Fittings: 3/4" NPT pipe  
fittings at the bottom of the  
unit.  
1
"
7 4  
Operating Pressure: Min 25  
PSI, Max 150 PSI.  
OUTLET  
INTLET  
1
"
ELECTRICAL  
SUPPLY  
4 4  
Min Flow 0.7 GPM  
Max Flow 6.0 GPM  
Series Four (Single Phase)  
Model  
kW  
Temperature Rise °F  
1.0 2.0 2.5 3.0 4.0 5.0 6.0  
GPM GPM GPM GPM GPM GPM GPM  
Recommended  
Wire Size  
Please consult local codes for electrical  
Voltage  
AMPS  
Number  
Rating  
requirements. Additional voltages and wattages  
are available. For more information please consult  
factory.  
EFT-38000-4-F-10 38.0  
240  
160 (4x40 Amps) 129.8 129.8 103.8 86.5 64.9 51.9 43.3  
8 AWG  
The unit must have 4 independent electrical circuits using  
correctly rated wire and 4 circuit breakers. This unit can  
only be ordered with 240V, but can be used on 208V with  
25% reduced output (no model number change required).  
Refer to Voltage Identification Code Chart  
on page 5.  
Applications: Single Phase Only.  
Whole House Residential.  
Multi Fixture up to 6GPM.  
20316  
"
121  
8
"
931 32  
"
Specifications:  
Color: White  
Element: Four replaceable cartridge  
inserts  
Dimensions: 20316"x  
OUTLET  
INTLET  
1218"x 418  
"
Weight: 23 lbs.  
Materials:  
Cover: Enameled Steel.  
Glass reinforced “UDEL†” Heater  
Body and Ni Chrome Element  
Pipe-Fittings: 3/4" NPT pipe fittings  
at the bottom of the unit.  
Operating Pressure: Min 25 PSI,  
Max 150 PSI.  
ELECTRICAL  
SUPPLY  
41  
8
"
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electric Instantaneous Water Heaters  
Thermostatic Triple Module Models (Three Phase)  
Min Flow 0.7 GPM  
Max Flow 4.0 GPM  
Model  
kW  
Temperature Rise °F  
2.0 2.5 3.0 3.5 4.0  
GPM GPM GPM GPM GPM GPM  
Recommended  
Voltage AMPS  
Please consult local codes for electrical requirements.  
Additional voltages and wattages are available. For more  
information please consult factory.  
Number  
Rating  
Wire Size  
1.5  
EFT-18000-2-T-10 18.0 208y/120v 50.0  
EFT-24000-2-T-10 24.0 208y/120v 67.0  
EFT-18000-6-T-10 18.0 480y/277v 21.7  
EFT-24000-6-T-10 24.0 480y/277v 28.9  
EFT-32000-6-T-10 32.0 480y/277v 38.5  
82  
82  
61  
82  
61  
82  
49  
65  
49  
65  
87  
41  
54  
41  
54  
73  
35  
47  
35  
47  
62  
32  
41  
32  
41  
55  
10 AWG  
10 AWG  
10 AWG  
10 AWG  
8 AWG  
Refer to Voltage Identification Code Chart  
and wiring diagram on page 5.  
Multi-Outlet Three Phase Applications: Modular Hand  
Washing, Multi-Shower, Restaurants, Beauty Salons.  
These models are not certified to be installed in Canada.  
1
"
15 4  
SPEC OPTIONS:  
S = Sanitation 180°F  
ML = Multi-Lav temp  
setting 105 to  
110 - 0.5 turn on up  
to 8 lavs  
FS = Factory Set  
(ambient to 180°F)  
1
"
12 4  
Specifications:  
Dimensions:  
1514"x 1214"x 414  
Weight: 15 lbs.  
Materials:  
"
1
"
7 4  
Cover: Enameled Steel.  
Glass reinforced “UDEL†” Heater  
Body and Ni Chrome Element  
Color: White  
OUTLET  
INTLET  
Element: Triple replaceable  
cartridge inserts  
Pipe-Fittings: 1/2" compression  
at bottom of unit.  
1
"
ELECTRICAL  
SUPPLY  
4 4  
Operating Pressure: Min 25 PSI,  
Max 150 PSI.  
Example: ES-5500-4-S-10-S  
The 4 in the model number indicates 240 volt.  
Voltage Identification Code  
For All Models  
Please be advised that the voltages listed in the Voltage Identification Code  
may not be available for all models.  
1
2
3
4
5
6
7
8
Voltage Code  
Voltage  
120 208 220 240 277 480Y/277V 380 415  
Additional voltages and wattages are available. For more information please  
consult factory.  
Electrical Configurations and Requirements for Bradford White Three Phase Tankless Water Heaters.  
All Bradford White three-phase units are custom made to order and as such are, non-returnable and non-refundable. We urge you therfore to check your  
electrical supply, making sure all criteria for operating your Bradford White water heaters are met, especially that a neutral line is available for all 480Y/277V volt units.  
L1  
L1  
Bradford White 208/120 Three Phase Units  
Delta Configuration  
Requires: 3 Lives, 1 Ground (earth)  
Bradford White 480Y/277V Three Phase Units  
Star Configuration  
Requires: 3 Lives, 1 Neutral and  
1 Ground  
N
L2  
L3  
L2  
L3  
Three-Phase delta; Three-wire  
Three-Phase star; Four-wire; non-earthed neutral  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electric Instantaneous Water Heaters  
Suggested Specification:  
Instantaneous Water Heater shall be a Bradford White Model __________ with __________kW, _________vac ______________  
to heat ________GPM @ a temperature rise of __________ degrees F. Unit shall have ABS UL 94 Vo rated cover. Heater body  
and element shall be glass reinforced UDEL.† Element shall be replaceable cartridge insert. Unit shall have a replaceable  
filter in the inlet connector. Element shall be iron free, nickel-chrome material. Heater shall be fitted with 1/2" compression  
nuts and sleeves to eliminate need for soldering. Maximum operating pressure of 150 psi. Hot water storage tanks  
prohibited. Unit shall be Bradford White or approved equal.  
Note: All models are Single Phase except the Thermostatic Three Phase (3 Module) Models.  
Kwickshot models are not recommended for Space Heating Applications.  
No chemicals shall be added to the Kwickshot models: Potable Water Only.  
U.S. Patent No.’s: 4,762,980 and 4,960,976  
UL Patent #'s 4,762,980 and 4,960,976.  
UL Listed: E197168  
- Only for 240 Volt and below Single Phase Models  
Typical Flow Rates in Gallons per Minute (gpm)  
Fixture  
Type  
Kitchen  
Sink  
Pantry  
Sink  
Laundry  
Sink  
Lavatory  
Bathtub  
Shower  
Dishwasher  
1.0-3.0  
Flow  
Rates  
0.5  
2.0-4.0  
1.5-4.0  
1.0-1.5  
1.5-2.5  
2.5-3.0  
FLOW CHART  
POWER REQUIRED-kW  
10 29.34kW  
44kW  
39.5kW  
35.1kW  
30.7kW  
26.4kW  
22kW  
58.6kW  
52.7kW  
49.9kW  
41kW  
73.2kW  
9
8
7
6
5
4
3
2
1
26.4kW  
23.4kW  
20.5kW  
17.6kW  
14.6kW  
11.7kW  
8.8kW  
5.8kW  
3.0kW  
65.9kW  
58.6kW  
51.2kW  
44kW  
82kW  
70.3kW  
61.5kW  
52.7kW  
44kW  
GPM  
82kW  
71.5kW  
61.5kW  
51.2kW  
41kW  
79kW  
70.3kW  
58.6kW  
46.9kW  
35.1kW  
23.4kW  
11.7kW  
5.8kW  
35.1kW  
29kW  
79kW  
37kW  
65.9kW  
52.7kW  
39.5kW  
26.4kW  
13.0kW  
6.5kW  
90˚F  
73.2kW  
17.6kW  
13.0kW  
8.8kW  
4.4kW  
23.4kW  
17.6kW  
11.7kW  
5.8kW  
3.0kW  
40˚F  
29kW  
35.1kW  
26.4kW  
17.6kW  
8.8kW  
4.4kW  
60˚F  
58.6kW  
44kW  
64.4kW  
48.3kW  
32.2kW  
16.1kW  
8kW  
22kW  
30.7kW  
20.5kW  
10.2kW  
5.1kW  
70˚F  
14.6kW  
7.3kW  
3.6kW  
50˚F  
29.3kW  
14.6kW  
7.3kW  
100˚F  
1
/2  
20˚F  
30˚F  
80˚F  
110˚F  
Temperature Rise - ˚F  
FORMULAS  
Flow Rate, (GPM) = kW rating x 6.83  
rise in temp. (°F)  
Rise in Temp. (°F) = kW rating x 6.83  
rise in temp. (°F)  
kW Rating =  
GPM x rise in temp.  
6.83  
Ambler, PA  
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.  
G
G
G
G
Sales 800-523-2931 Fax 215-641-1670 / Technical Support 800-334-3393 Fax 269-795-1089 Warranty 800-531-2111 Fax 269-795-1089  
G
International: Telephone 215-641-9400 Telefax 215-641-9750 / www.bradfordwhite.com  
G
Sales / Technical Support 866-690-0961 / 905-238-0100 Fax 905-238-0105 / www.bradfordwhite.com  
©2008, Bradford White Corporation. All rights reserved.  
217-B-1108-A  
Printed in U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bissell Yard Vacuum 6594 User Manual
Black Box Network Router 80211G User Manual
Black Decker Hot Beverage Maker TR200JA User Manual
Bosch Appliances Range HGS3023UC User Manual
Bosch Power Tools Grinder 1775E User Manual
Boss Audio Systems Stereo Receiver 612UA User Manual
Brother Sewing Machine 885 V35 V37 User Manual
Casio Watch 2326 User Manual
CDA Washer CI230 User Manual
Chauvet Indoor Furnishings STRIKE 324 User Manual