QUADX & QUAD 3Km FLASH HEADS
USER GUIDE BWL-0328/2 (03/07)
BOWENS INTERNATIONAL LIMITED
355 Old Road
Clacton On Sea
Essex CO15 3RH
Tel: +44 (0)1255 422807
Fax: +44 (0)1255 436342
ʻBowensʼ ® and ʻthe power behind the pictureʼ ® are registered trademarks of Bowens International Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Accessories
High-Performance Reflector
Dear Valued Customer,
This 32cm reflector achieves the
maximum amount of light output
possible for lighting large groups
and bouncing light off of high
ceilings. The efficient parabolic
design delivers a narrow, bright
beam of light with intense shadows
and high contrast. A must where
Thank you for choosing the Bowens Quad head professional flash system.
Accurate, ergonomic, powerful and simple to use, the Quad heads have been designed by working
closely with photographers to develop a flash that meets the standards demanded in professional
studios today. All ʻS-Typeʼ accessories from the Bowens range can be used with the Quad heads. For
details of all related products, please contact your local distributor, a list of which can be found at
sheer power is required. BW1878
www.bowens.co.uk. In order to obtain the full benefit from your purchase, please take a few moments
to familiarise yourself with this user manual.
Backlite Reflector
Thank you.
With its 20 x 30.5cm (8 x 12”)
elliptical shape, this reflector
produces an oval pool of light
that can be used to create a
Bowens International Ltd.
natural
vignette
on
a
Safety Notes
background or other areas. Two
fitted spring clips allow colour
gels to be fitted. BW2560
DO NOT:
• Use in an environment where moisture or flammable vapour is likely to come in contact with the
A set of colour gels including seven popular colours, a neutral-density filter and two diffusers for
unit.
heightened lighting creativity is also available for the Backlite reflector. BW2552
• Restrict air vents while in use.
• Use a unit with damaged housing, mouldings, flash tube or modelling lamp.
If the unit is dropped or damaged in any way, always have it checked out before using.
• Operate the unit without a safe grounded (earthed) AC supply.
40° Sunlite Reflector
A
43cm (17”) white-painted
reflector designed to replicate
sunlight for photographing items
such as architectural models. The
white painted interior of the
Sunlite helps to ensure that an
even light is delivered. BW1868
DO:
• Read Instructions before use
• Switch power off and disconnect from the supply before changing modelling bulb or flash tube.
• Disconnect the supply before changing the fuse. Never replace with a fuse of a different rating.
• Exercise care when handling equipment that has been in use. The reflector and front end of the
unit can become very hot.
• Avoid placing cables where they can be tripped over. Protect from heavy, sharp or hot objects,
which may cause damage and replace damaged cables immediately.
• Due to the high voltage / high energy used in all Bowens units, all servicing must be carried out
by an authorised Service Centre.
DID YOU KNOW? that Bowens have over 40 light shaping tools
and accessories available for all their monolights that use the
current ʻSʼ type accessory fitting. Included among the range of
accessories are a wide variety of reflectors and softboxes. For
more information visit the website on www.bowens.co.uk
• Ensure that any extension cord used has a suitable current rating to prevent overheating and
never use coiled extension cords.
• ALWAYS remove the flash head covers before using.
Download from Www.Somanuals.com. All Manuals Search And Download.
Modelling Lamp Replacement
Operation
Avoid moving or knocking the unit when the lamp is switched on or when it has just been turned off since
the lamp filaments can be damaged when hot.
!!! WARNING HIGH VOLTAGE !!!
NOTE: Select and fit a modelling lamp suitable for the mains power supply voltage connected to the
generator. Only use lamps as recommended in the specification.
THIS APPLIANCE MUST BE EARTHED WHEN USED.
ALWAYS DISCONNECT THE UNIT WHEN CHANGING
MODELLING LAMPS & FLASH TUBES.
Flash Tube Replacement
Select a stand or support system of suitable weight and dimensions to ensure stable operation of the
unit. Ensure that the clamp screw is fully tightened. The angle of the head may be set using the locking
handle, always support the flash head before releasing the handle and never force adjustment without
releasing the handle.
Before attempting to replace the flash tube, switch off the pack and disconnect the flash head cable.
Follow the instructions for removing the cover dome.
Move the latch release back towards the rear of the unit, rotate and remove the plastic protective cap.
Always refit the cap when transporting the unit to avoid damage. NEVER operate the unit with the cap
still in place.
Unwind the twisted trigger wire from the terminal and carefully pull the flash tube assembly out of the
unit.
Avoid directly touching the glass envelope of the new tube by using the original packaging or a clean
cloth to grip the tube.
Before connecting the flash head to the pack confirm that the lamp, flash tube and cover glass are
securely fitted; particularly before first use or after transporting the unit. Refer to the section on
replacement if required. Never operate without the cover glass fitted.
Gently locate the three brass sockets into the plugs in the front of the unit. Press down evenly until all
of the plugs and sockets are fully engaged. Pass the trigger wire through the hole in the trigger terminal
tag and wind around the tag, ensuring the trigger wire is kept well clear of the metal top hat. Trim off
excess wire and refit the cover glass.
The modelling lamp is controlled from the generator pack and will respond to all of the pack controls
including the dimmer option. The switch on the rear allows the modelling lamp of individual heads to be
turned off.
Modelling Lamp Replacement
Connection
Before attempting to replace the modelling lamp, switch off the pack and disconnect the flash head
cable. This is particularly important if the lamp glass is broken. Wait a few minutes for the lamp and tube
to cool.
To connect the flash head, first ensure the pack is switched off and disconnected from the mains supply.
Insert the tab on the front of the cable plug into the socket first and then press down firmly on the cable
entry end to ensure latched retention. To remove the plug, press the spring latch away from the plug
and lift from the cable entry end.
Remove the glass dome by depressing both retaining buttons (for the QuadX head, or simply gently
slide the glass dome over the flash tube and modelling lamp for the Quad 3Km head) and carefully lifting
it off. Remove the lamp from the QuadX head by gently pulling it from its socket, for the Quad 3Km
gently unscrew the lamp from its fitting. Take care if the lamp envelope is broken - use a cloth or gloves.
Reflector / Accessory System
Natural grease and oils from the hands can dramatically shorten the working life of a lamp so avoid
directly touching the glass envelope of the new lamp. Use the original packing or a clean cloth to grip
the lamp. Accidental contamination may be removed with a clean cloth and a small quantity of
methylated spirits.
A range of reflectors and accessories are available for the flash head. Slide the neck of the reflector /
accessory over the front of the unit. Align the three pegs with the three slots in the retaining ring, press
down and turn clockwise to lock. Ensure that the latch release is in the closed position.
To remove any reflector / accessory, push the latch release towards the rear of the unit, turn the
reflector fully counter clockwise and withdraw.
Replacement is the reverse of removal but ensure that the lamp is fully inserted into the socket. If the
new lamp fails to light then check the lamp circuit breaker on the pack and the lamp fuse on the flash
head, as this may rupture when a lamp fails. Replace a blown fuse with one of the correct type and
rating, a spare 4A (F) fuse is included with every Quad flash heads.
Download from Www.Somanuals.com. All Manuals Search And Download.
|