Ventilation Hood
Ho u s e h o ld Ap p lia n c e s
Installation Instructions
for Model Numbers Beginning with DAH93,
DAH94 and DAH95
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT: Save these instructions.
INSTALLER: Please leave these instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Figure 1 - DAH93 and DAH94 models
General Information
1. For the most efficient air flow exhaust, use a straight
run or as few elbows as possible.
Blower Cord Connector
Connector Access Panel
2. Do not use flex ducting.
3. COLD WEATHER installations should have an additional
backdraft damper installed to minimize backward cold
air flow and a nonmetallic thermal break to minimize
conduction of outside temperatures as part of the
ductwork. The damper should be on the cold air side of
the thermal break. The break should be as close as
possible to where the ducting enters the heated portion
of the house.
4. Hood installation height above cooktop is the user’s
preference. The lower the hood above the cooktop, the
more efficient the capturing of cooking odors, grease,
and smoke. This hood has been approved for installations
as low as 24 inches and as high as 36” above the cooktop.
The lower height may be inconvenient for tall people
and large cooking vessels. Consequently, Bosch
recommends the hood be installed 30”-36” above the
countertop.
Rear Filter Rail
J Box
Figure 2 - DAH95 models with internal blower
Blower Cord Connector
5. Remote blowers require a five wire installation.
Connector Access Panel
6. Make-Up Air: Local building codes may require the use
of make-up air systems when using ducted ventilation
systems greater than specified CFM of air movement.
The specified CFM varies from locale to locale. Consult
your HVAC professional for specific requirements in your
area.
Blower
1. Unpack Hood
Pull hood from outer packaging and remove all
packaging materials.
J Box
Mounting Plate
Rear Filter Rail
2. Remove Knockout
Remove the appropriate blower duct knockout. For
horizontal discharge, remove the knockout in the back
wall of the hood. For vertical discharge, remove the
knockout in the top of the hood.
Figure 3 - DAH95 models with remote blower
Remote Wire Cover
3. Install Internal Blower (DAH95 models only)
If your hood is already equipped with a blower, or you
will be using a remote blower, proceed to
Step 4: Install Transition (next page).
1. Remove rear filter rail.
2. Remove blower control wire cover.
3. Remove J box.
White Connector
4. With hood standing on its back wall, place blower
in center of hood.
5. Screw 6 screws (3 on each side) through mounting
plates. See Figure 2.
J Box
Rear Filter Rail
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
are 15 3/4” from the center line (See Figure 5).
4. Install Transition
4. Place the hood.
For internal blower installation, install the 7”
transition (included) to connect to 7” ducting. If 7”
ducting is not available, 8” ducting may be used. In
this instance, an additional 7-8” transition must also be
used (not included).
5. Tighten the screws.
For remote blower applications, 10” ducting is
required. In this instance, a 7”-10” transition must
also be used.
Attach the transition with 4 #8 sheetmetal screws
(included) and seal connection with duct tape.
Figure 4 - Wall Mount
5. Mount the Hood
C
L
The DAH model hood can be mounted through the
back wall or through the top. See General Information,
page 1, for suggestions for hood height.
Once the preferred height is determined, locate the
centerline (left to right) of the cooking appliance.
15-3/8"
from CL
Wall Mount
1. From the centerpoint of the cooking appliance,
measure up to the preferred height. Measure up an
additional 9” to locate the centerline of the screw
holes (see Figure 4).
9"
11-1/2"
from CL
30" - 36"
2. Install toggle bolts through drywall leaving 1/4” of
the bolt exposed.
Install one togglebolt 11 1/2” to the left of the
centerline and one togglebolt 11 1/2” to the right
of the centerline. These are the only installation
points for the 30” hood. See Figure 4
For the 36” hood, there are 2 additional installation
points. These are also at the centerline height, but
are 15 3/8” from the centerline in each direction.
See Figure 4.
3. Place the hood by sliding the mounting holes in the
hood over the bolts.
4. Tighten the bolts.
Top Mount
1. Install the hood flush against the back wall.
Figure 5 - Top Mount
CL
2. Identify the centerline on the mounting surface
(underside of cabinet).
Front
3. Place the hood and install the drywall screws
through the mounting holes.
Insert 3 drywall screws 11 1/2” off the
centerline in both directions at the following
depths:
1"
6"
1. 2 1/4” from the back wall
2. 8 1/4” from the back wall
3. 9 1/4” from the back wall
(See Figure 5).
2 1/4"
The 36” hood also requires 3 additional screws, at
the same depths, on each side (total of 6). These
Back
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
6. Connect Wiring
Accessories
The following accessories are available from your Bosch
dealer or through Bosch Service: 800-944-2904. Please
reference the model number when requesting these items.
WARNING:
Use only spring type wire nuts (included) to make
electrical connections. Replacement wire nuts must be
rated for a minimum of (2) #18ga wires and a maximum
of 4 #14ga wires, UL & CSA rated to 600V and 302º F/
150º C. Request #189692 when ordering from
BSH.
Accessory
6” Duct Covers
Biscuit
Black
Stainless Steel
White
Model #
30”
36”
N/A
DCZ7607UC
DCZ7606UC
DCZ9666UC
DCZ7605UC DCZ9665UC
DCZ7602UC DCZ9662UC
For Internal Blower Use:
12” Duct Covers
Biscuit
Black
Stainless Steel
White
Recirculation Kit
Biscuit
Black
Stainless Steel
White
Charcoal Filter
3 1/4 x 10Transition
Blowers*
Integral Blower, 400 CFM
Integral Blower, 600 CFM
Remote Blower, 600 CFM
Remote Blower, 1000 CFM
30”
36”
N/A
DCZ9266UC
DCZ9265UC
DCZ9262UC
36”
See Figure 1 or 2, page 3.
1. Remove electrical knockout behind J box and
install 1/2” conduit connectors.
DCZ7207UC
DCZ7206UC
DCZ7205UC
DCZ7202UC
30”
DRZ7007UC
DRZ7006UC
DRZ7005UC DRZ9065UC
DRZ7002UC DRZ9062UC
DHZ7960UC
2. Run 120V AC 60Hz, 15A supply wires through 1/2”
conduit to hood electrical knockout behind J box
cover.
N/A
DRZ9066UC
3. Connect blower cord wires to house wiring through
electrical knockouts. Use wire nuts supplied (white
to white, black to black, green to green).
4. Connect blower cord at white connector behind
connector access panel (if not already connected).
Verify that connectors are tightly connected.
For Remote Blower Use:
See Figure 3, page 3.
DHZ3410UC
DHG4001UC
DHG6001UC
DHG6003UC
DHG1003UC
1. Remove 2 hood electrical knockouts and install
1/2” conduit connectors.
2. Run black, white and green supply wires through
1/2” conduit to hood electrical knockout behind
J box.
*for use with DAH95 models only
Figure 6 - Remote Blower Pigtail Assembly
3. Connect power supply wires to hood wires behind
J box (white to white, black to black, green to
green). Use wire nuts supplied.
GND L1
N
4. Run 5 wires (#14 AWG) in 1/2” conduit from the
remote blower to the electrical knockout behind
the remote wire cover.
BLACK
5. Connect remote blower wiring to “pigtail” wires
behind remote wire cover with wire nuts supplied
(white to white, black to black, green to green and
black to brown, white to white, red to red and
blue to blue) See Figure 6.
WHITE
6. Connect other end of “pigtail” at white connector.
Verify that connectors are tightly connected.
BROWN
WHITE
RED
M
7. Reassemble Hood
BLUE
Reattach the following:
GND
1. Connector access panel (internal blower only)
2. J box
3. Remote wire cover (remote blower use only)
4. Back filter rail
5. Filters
5
Download from Www.Somanuals.com. All Manuals Search And Download.
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/944-2904
5060008728 Rev. A (ECO# 5V01MD)
© BSH Home Appliances Corporation 2003 • Litho U. S. A. 8/03