Installation  
Figure 1 - DAH93 and DAH94 models  
General Information  
1. For the most efficient air flow exhaust, use a straight  
run or as few elbows as possible.  
Blower Cord Connector  
Connector Access Panel  
2. Do not use flex ducting.  
3. COLD WEATHER installations should have an additional  
backdraft damper installed to minimize backward cold  
air flow and a nonmetallic thermal break to minimize  
conduction of outside temperatures as part of the  
ductwork. The damper should be on the cold air side of  
the thermal break. The break should be as close as  
possible to where the ducting enters the heated portion  
of the house.  
4. Hood installation height above cooktop is the user’s  
preference. The lower the hood above the cooktop, the  
more efficient the capturing of cooking odors, grease,  
and smoke. This hood has been approved for installations  
as low as 24 inches and as high as 36” above the cooktop.  
The lower height may be inconvenient for tall people  
and large cooking vessels. Consequently, Bosch  
recommends the hood be installed 30”-36” above the  
countertop.  
Rear Filter Rail  
J Box  
Figure 2 - DAH95 models with internal blower  
Blower Cord Connector  
5. Remote blowers require a five wire installation.  
Connector Access Panel  
6. Make-Up Air: Local building codes may require the use  
of make-up air systems when using ducted ventilation  
systems greater than specified CFM of air movement.  
The specified CFM varies from locale to locale. Consult  
your HVAC professional for specific requirements in your  
area.  
Blower  
1. Unpack Hood  
Pull hood from outer packaging and remove all  
packaging materials.  
J Box  
Mounting Plate  
Rear Filter Rail  
2. Remove Knockout  
Remove the appropriate blower duct knockout. For  
horizontal discharge, remove the knockout in the back  
wall of the hood. For vertical discharge, remove the  
knockout in the top of the hood.  
Figure 3 - DAH95 models with remote blower  
Remote Wire Cover  
3. Install Internal Blower (DAH95 models only)  
If your hood is already equipped with a blower, or you  
will be using a remote blower, proceed to  
Step 4: Install Transition (next page).  
1. Remove rear filter rail.  
2. Remove blower control wire cover.  
3. Remove J box.  
White Connector  
4. With hood standing on its back wall, place blower  
in center of hood.  
5. Screw 6 screws (3 on each side) through mounting  
plates. See Figure 2.  
J Box  
Rear Filter Rail  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
are 15 3/4” from the center line (See Figure 5).  
4. Install Transition  
4. Place the hood.  
For internal blower installation, install the 7”  
transition (included) to connect to 7” ducting. If 7”  
ducting is not available, 8” ducting may be used. In  
this instance, an additional 7-8” transition must also be  
used (not included).  
5. Tighten the screws.  
For remote blower applications, 10” ducting is  
required. In this instance, a 7”-10” transition must  
also be used.  
Attach the transition with 4 #8 sheetmetal screws  
(included) and seal connection with duct tape.  
Figure 4 - Wall Mount  
5. Mount the Hood  
C
L
The DAH model hood can be mounted through the  
back wall or through the top. See General Information,  
page 1, for suggestions for hood height.  
Once the preferred height is determined, locate the  
centerline (left to right) of the cooking appliance.  
15-3/8"  
from CL  
Wall Mount  
1. From the centerpoint of the cooking appliance,  
measure up to the preferred height. Measure up an  
additional 9” to locate the centerline of the screw  
holes (see Figure 4).  
9"  
11-1/2"  
from CL  
30" - 36"  
2. Install toggle bolts through drywall leaving 1/4” of  
the bolt exposed.  
Install one togglebolt 11 1/2” to the left of the  
centerline and one togglebolt 11 1/2” to the right  
of the centerline. These are the only installation  
points for the 30” hood. See Figure 4  
For the 36” hood, there are 2 additional installation  
points. These are also at the centerline height, but  
are 15 3/8” from the centerline in each direction.  
See Figure 4.  
3. Place the hood by sliding the mounting holes in the  
hood over the bolts.  
4. Tighten the bolts.  
Top Mount  
1. Install the hood flush against the back wall.  
Figure 5 - Top Mount  
CL  
2. Identify the centerline on the mounting surface  
(underside of cabinet).  
Front  
3. Place the hood and install the drywall screws  
through the mounting holes.  
Insert 3 drywall screws 11 1/2” off the  
centerline in both directions at the following  
depths:  
1"  
6"  
1. 2 1/4” from the back wall  
2. 8 1/4” from the back wall  
3. 9 1/4” from the back wall  
(See Figure 5).  
2 1/4"  
The 36” hood also requires 3 additional screws, at  
the same depths, on each side (total of 6). These  
Back  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
6. Connect Wiring  
Accessories  
The following accessories are available from your Bosch  
dealer or through Bosch Service: 800-944-2904. Please  
reference the model number when requesting these items.  
WARNING:  
Use only spring type wire nuts (included) to make  
electrical connections. Replacement wire nuts must be  
rated for a minimum of (2) #18ga wires and a maximum  
of 4 #14ga wires, UL & CSA rated to 600V and 302º F/  
150º C. Request #189692 when ordering from  
BSH.  
Accessory  
6” Duct Covers  
Biscuit  
Black  
Stainless Steel  
White  
Model #  
30”  
36”  
N/A  
DCZ7607UC  
DCZ7606UC  
DCZ9666UC  
DCZ7605UC DCZ9665UC  
DCZ7602UC DCZ9662UC  
For Internal Blower Use:  
12” Duct Covers  
Biscuit  
Black  
Stainless Steel  
White  
Recirculation Kit  
Biscuit  
Black  
Stainless Steel  
White  
Charcoal Filter  
3 1/4 x 10Transition  
Blowers*  
Integral Blower, 400 CFM  
Integral Blower, 600 CFM  
Remote Blower, 600 CFM  
Remote Blower, 1000 CFM  
30”  
36”  
N/A  
DCZ9266UC  
DCZ9265UC  
DCZ9262UC  
36”  
See Figure 1 or 2, page 3.  
1. Remove electrical knockout behind J box and  
install 1/2” conduit connectors.  
DCZ7207UC  
DCZ7206UC  
DCZ7205UC  
DCZ7202UC  
30”  
DRZ7007UC  
DRZ7006UC  
DRZ7005UC DRZ9065UC  
DRZ7002UC DRZ9062UC  
DHZ7960UC  
2. Run 120V AC 60Hz, 15A supply wires through 1/2”  
conduit to hood electrical knockout behind J box  
cover.  
N/A  
DRZ9066UC  
3. Connect blower cord wires to house wiring through  
electrical knockouts. Use wire nuts supplied (white  
to white, black to black, green to green).  
4. Connect blower cord at white connector behind  
connector access panel (if not already connected).  
Verify that connectors are tightly connected.  
For Remote Blower Use:  
See Figure 3, page 3.  
DHZ3410UC  
DHG4001UC  
DHG6001UC  
DHG6003UC  
DHG1003UC  
1. Remove 2 hood electrical knockouts and install  
1/2” conduit connectors.  
2. Run black, white and green supply wires through  
1/2” conduit to hood electrical knockout behind  
J box.  
*for use with DAH95 models only  
Figure 6 - Remote Blower Pigtail Assembly  
3. Connect power supply wires to hood wires behind  
J box (white to white, black to black, green to  
green). Use wire nuts supplied.  
GND L1  
N
4. Run 5 wires (#14 AWG) in 1/2” conduit from the  
remote blower to the electrical knockout behind  
the remote wire cover.  
BLACK  
5. Connect remote blower wiring to “pigtail” wires  
behind remote wire cover with wire nuts supplied  
(white to white, black to black, green to green and  
black to brown, white to white, red to red and  
blue to blue) See Figure 6.  
WHITE  
6. Connect other end of “pigtail” at white connector.  
Verify that connectors are tightly connected.  
BROWN  
WHITE  
RED  
M
7. Reassemble Hood  
BLUE  
Reattach the following:  
GND  
1. Connector access panel (internal blower only)  
2. J box  
3. Remote wire cover (remote blower use only)  
4. Back filter rail  
5. Filters  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/944-2904  
5060008728 Rev. A (ECO# 5V01MD)  
© BSH Home Appliances Corporation 2003 • Litho U. S. A. 8/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Boston Acoustics Home Theater System high powered subwoofer User Manual
Bowflex Stepper Machine TC5500 User Manual
Braun Trimmer 5377 User Manual
Bravetti Electric Grill EP865 User Manual
Bush Hog Brush Cutter 3715 User Manual
Cable Electronics MP3 Player CAT5TX RX User Manual
Canon Projector LV S1 User Manual
Chicago Electric Automobile Battery Charger 95000 User Manual
Chief Manufacturing Indoor Furnishings FHP 110 User Manual
Cisco Systems Lawn Mower MM275 User Manual