Bosch Appliances Smoke Alarm EVAX25E User Manual

Fire Alarm Systems | Bosch Voice Evacuation Systems  
Bosch Voice Evacuation Systems  
Digitally‑recorded automatic evacuation message (up  
to 4 minutes of message capacity)  
Alarm and alert signals  
Live microphone override of message and tone  
Compatible with 12 V or 24 V, analog‑addressable or  
microprocessor‑based fire alarm control panels  
(FACPs)  
Clean dead‑front construction  
Easy installation and operation  
24‑hour backup with 7 Ah batteries installed (batteries  
not supplied)  
The Bosch Voice Evacuation systems and expansion panels  
provide a variety of options that can be easily added to an  
existing fire alarm control panel system for area of assembly  
applications and for high‑rise voice evacuation not requiring  
firemens' phones. Choose up to 2000 W of audio amplifier  
power to meet your speaker power requirements. You can  
supervise multiple zones through your choice of zone  
splitters.  
The EVAX25, EVAX50, and EVAX100 respectively provide  
25 W, 50 W, and 100 W of audio amplifier power in a  
standard‑size enclosure. The EVAX150 has one 50 W audio  
amplifier and one 100 W audio amplifier in a double‑size  
enclosure. The EVAX200 has two 100 W amplifiers in a  
double‑size enclosure.  
Customize these systems to satisfy most application  
requirements by adding expander panels, expander  
modules, or zone splitters. Expanders can be grouped  
together in any combination to provide up to 2000 W of  
audio power.  
System Overview  
Optional Expander Panels  
BOSCH Voice Evacuation Systems  
All Bosch voice evacuation systems include all the  
necessary features to provide an effective voice evacuation  
system:  
The Bosch system expander panels provide an easy and  
cost-effective way to increase the output power of a Bosch  
voice evacuation system. They can also provide a  
manually‑activated emergency paging panel for buildings.  
Features of the EVAX25E, EVAX50E, and EVAX100E:  
Audio amplifier  
Digital message repeater (DMR)  
120 VAC power transformer and battery charger  
Tone generator  
Paging microphone  
Surface‑mount or semi‑flush‑mount enclosure with a  
Audio amplifier  
120 VAC power transformer and battery charger  
Tone generator  
Paging microphone  
hinged, key‑locked door in charcoal‑gray (standard) or  
red (optional)  
Standard‑size enclosure with a hinged, key‑locked door  
The EVAX150E and EVAX200E expander panels provide the  
same features with additional power in a double‑size  
enclosure housing two amplifier modules.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bosch Voice Evacuation Systems | 3  
Speaker Wiring Requirements  
Category  
Product  
The 25 V speaker circuits of most voice evacuation systems  
are classified as power‑limited wiring and can be run with  
other fire alarm wiring without ill effects. No special cabling  
is required. Standard power‑limited fire alarm cable (FPL)  
is sufficient for most applications; however, certain  
addressable systems can generate extraneous noise from  
their addressable loop. Because these addressable systems  
cannot use shielded cable, shielding of the evacuation  
speaker circuit helps to eliminate noise picked up and heard  
in the speakers. When using 70 V circuits, separate them as  
described in the National Electrical Code.  
Expansion  
Modules  
EVX‑25 25 W Amplifier with DMR and microphone  
EVX‑25E 25 W Amplifier without DMR, with microphone  
EVX‑25EM 25 W Amplifier without DMR and microphone  
EVX‑50 50 W Amplifier with DMR and microphone  
EVX‑50E 50 W Amplifier without DMR, with microphone  
EVX‑50EM 50 W Amplifier without DMR and microphone  
EVX‑100 100 W Amplifier with DMR and microphone  
EVX‑100E 100 W Amplifier without DMR, with microphone  
EVX‑100EM100WAmplifierwithoutDMRandmicrophone  
EVX‑RM Charcoal‑gray Remote Microphone Panel  
Remote  
Microphones  
Generally, 18 AWG (1.0 mm) wire is adequate for speakers.  
Heavier wire is needed if loads are high or the runs are long.  
The following table indicates typical wire lengths for  
specific wire sizes and speaker loads. It assumes that there  
is an even distribution of speaker load and that a 20% drop  
at the last device is allowable.  
EVX‑RMR Red Remote Microphone Panel  
EVX‑2ZA Class A Zone Splitter  
Zone  
Splitters  
EVX‑4Z Class B Zone Splitter  
Speaker Placement  
25 VRMS Output:  
Choose speakers that deliver a minimum ambient sound of  
15 dB above the normal ambient noise level. In  
high‑ambient noise areas, speakers should be tapped at  
15 dB to 21 dB above the ambient noise level and placed  
closer to one another to ensure that voice messages are  
intelligible.  
Power 18 AWG  
(1.0 mm)  
16 AWG  
14 AWG  
12 AWG  
(1.3 mm)  
(1.6 mm)  
(2.0 mm)  
10 W  
15 W  
25 W  
1900 ft  
(579 m)  
3050 ft  
(930 m)  
4850 ft  
(1478 m)  
7700 ft  
(2347 m)  
1280 ft  
(390 m)  
2030 ft  
(619 m)  
3230 ft  
(985 m)  
5140 ft  
(1567 m)  
760 ft  
(232 m)  
1220 ft  
(372 m)  
1930 ft  
(588 m)  
3080 ft  
(939 m)  
The best way to determine speaker placement needs is to  
conduct a site survey with a decibel meter to measure  
ambient noise levels; however, some general rules for  
speaker placement are:  
70 VRMS Output:  
Power 18 AWG  
(1.0 mm)  
16 AWG  
(1.3 mm)  
14 AWG  
(1.6 mm)  
12 AWG  
(2.0 mm)  
Locate speakers at all pull stations and in main  
corridors similar to the layout of conventional fire  
horns.  
10 W  
15 W  
25 W  
15200 ft  
(4633 m)  
24200 ft  
(7376 m)  
38360 ft  
(11692 m)  
61100 ft  
(18623 m)  
Ensure that all occupied locations are within 50 ft  
10130 ft  
(3088 m)  
16130 ft  
(4916 m)  
25570 ft  
(7794 m)  
40730 ft  
(12415 m)  
(15 m) of a speaker. Place additional speakers in rooms  
such as cafeterias and computer rooms. Be sure there  
are speakers in isolated areas where service personnel  
might be working.  
6080 ft  
(1853 m)  
9680 ft  
(2950 m)  
15340 ft  
(4676 m)  
24440 ft  
(7449 m)  
For ceiling‑mount speakers, use 2 W of speaker power  
for every 2000 ft (186 m ) of area covered in open  
System Power Requirements  
2
2
All Bosch voice evacuation systems require 120 VAC  
connected to the system's power transformer. Standby  
power is supplied, in case of AC power failure, by standby  
batteries (not supplied). The EVAX25, EVAX50, and  
EVAX100 require two 12 VDC, 7 Ah standby batteries. The  
EVAX150 and EVAX200 require four 12 VDC, 7 Ah standby  
batteries.  
2
2
areas and 2 W for every 1500 ft (139 m ) in divided  
areas. For wall‑mount speakers, use 1 W of speaker  
2
2
power for every 2000 ft (186 m ) of area covered in  
2
2
open areas and 1 W for every 1500 ft (139 m ) in  
divided areas.  
Speaker Power Requirements  
System power (total wattage) must be sufficient to supply  
the power required by all of the speakers on the system.  
Speaker transformers can often be tapped for different  
wattages (usually, ¼ W, ½ W, 1 W, etc.). A system rated at  
25 W of audio power can power a speaker load of 25 W. This  
can be made up of 25 speakers each tapped at 1 W, 50  
speakers each tapped at ½ W, or any mathematical  
combination that is less than or equal to 25 W.  
Technical Specifications  
Environmental Considerations  
Relative Humidity:  
Up to 95%, non condensing  
Temperature (Operating):  
+32°F to +120°F (0°C to +49°C)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 | Bosch Voice Evacuation Systems  
Mechanical Properties  
Power Requirements (Primary)  
Color:  
Standard: charcoal gray  
Optional: red  
Current (Input):  
25 W system: 0.8 A  
50 W system: 0.6 A  
100 W system: 2 A  
150 W system: 2.6 A  
200 W system: 4 A  
Dimensions (H x W x D):  
Standard: 18 in. x 14.5 in. x 4 in.  
(45.7 cm x 36.8 cm x 10.2 cm)  
Double-size: 27 in. x 14.5 in. x 4 in.  
(68.6 cm x 36.8 cm x 10.2 cm)  
Voltage (Nominal Input):  
120 VAC  
Material:  
16 gauge (1.5 mm) steel  
Outputs  
Tone and Voice  
(at 25/70 VRMS):  
25 W system: 25 W  
50 W system: 50 W  
100 W system: 100 W  
150 W system: 150 W  
200 W system: 200 W  
Power Requirements (Battery)  
Current (Alarm):  
Current (Standby):  
Power (Battery):  
25 W system: 1 A  
50 W system: 1 A  
100 W system: 2.5 A  
150 W system: 1 A  
200 W system: 5 A  
25 W system: 0.18 A  
50 W system: 0.13 A  
100 W system: 0.18 A  
150 W system: 0.31 A  
200 W system: 0.36 A  
24 VDC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bosch Voice Evacuation Systems | 5  
Bosch Voice Systems Information  
Bosch Voice Evacuation Systems with DMR and microphone)  
Consists of  
Consists of  
Consists of  
Model  
Model  
Model  
EVAX25*  
1
1
1
1
1
EVAX50*  
1
1
1
1
1
1
1
1
EVAX100*  
1
1
1
1
1
1
1
1
EVAX25*/4Z  
EVAX25*/8Z  
EVAX25*/2ZA  
1
1
1
1
2
EVAX50*/4Z  
EVAX50*/8Z  
EVAX50*/12Z  
1
2
3
EVAX100*/4Z  
EVAX100*/8Z  
EVAX100*/12Z  
2
3
1
2
EVAX25*/4ZA  
1
1
EVAX50*/16Z  
EVAX50*/2ZA  
EVAX50*/4ZA  
EVAX50*/6ZA  
EVAX50*/8ZA  
1
1
1
1
1
4
1
EVAX100*/16Z  
EVAX100*/2ZA  
EVAX100*/4ZA  
Evax100*/6ZA  
EVAX100*/8ZA  
1
1
1
1
1
4
1
1
2
3
4
1
1
1
2
3
4
1
1
1
1
1
1
Consists of  
Consists of  
Model  
Model  
EVAX150*  
1
1
1
1
1
1
1
1
EVAX200*  
1
1
1
1
1
1
1
1
EVAX150*/8Z  
EVAX150*/12Z  
EVAX150*/16Z  
EVAX150*/4ZA  
EVAX150*/6ZA  
EVAX150*/8ZA  
1
1
1
1
1
1
2
3
4
EVAX200*/8Z  
EVAX200*/12Z  
EVAX200*/16Z  
EVAX200*/4ZA  
EVAX200*/6ZA  
EVAX200*/8ZA  
1
1
1
1
1
1
2
3
4
2
3
4
2
3
4
* The asterisk (*) is not part of the number; it is a placeholder for indicating the color option. For a charcoal gray  
enclosure, drop the asterisk (*). For a red enclosure, replace the asterisk (*) with an R.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 | Bosch Voice Evacuation Systems  
EVAX Expansion Panels - EM models (without DMR, without microphone)  
Consists of  
Consists of  
Consists of  
Model  
Model  
Model  
EVAX25EM*  
1
1
1
1
1
EVAX50EM*  
1
1
1
1
1
EVAX100EM*  
1
1
1
1
1
1
1
EVAX25EM*/4Z  
EVAX25EM*/8Z  
EVAX25EM*/2ZA  
1
2
1
1
1
EVAX50EM*/4Z  
EVAX50EM*/8Z  
EVAX50EM*/12Z  
1
2
3
1
1
EVAX100EM*/4Z  
EVAX100EM*/8Z  
EVAX100EM*/12Z  
1
2
3
1
2
1
1
1
1
EVAX25EM*/4ZA  
1
1
EVAX50EM*/16Z  
EVAX50EM*/2ZA  
EVAX50EM*/4ZA  
EVAX50EM*/6ZA  
EVAX50EM*/8ZA  
1
1
1
1
1
4
EVAX100EM*/16Z  
EVAX100EM*/2ZA  
EVAX100EM*/4ZA  
Evax100EM*/6ZA  
EVAX100EM*/8ZA  
1
1
1
1
1
4
1
2
3
4
1
1
1
2
3
4
1
1
1
1
1
1
Consists of  
Consists of  
Model  
Model  
EVAX150EM*  
1
1
1
1
1
1
1
1
EVAX200EM*  
1
1
1
1
1
1
1
1
EVAX150EM*/8Z  
EVAX150EM*/12Z  
EVAX150EM*/16Z  
EVAX150EM*/4ZA  
EVAX150*/6ZA  
EVAX150*/8ZA  
1
1
1
1
1
1
2
3
4
EVAX200EM*/8Z  
EVAX200EM*/12Z  
EVAX200EM*/16Z  
EVAX200EM*/4ZA  
EVAX200EM*/6ZA  
EVAX200EM*/8ZA  
1
1
1
1
1
1
2
3
4
2
3
4
2
3
4
* The asterisk (*) is not part of the number; it is a placeholder for indicating the color option. For a charcoal gray  
enclosure, drop the asterisk (*). For a red enclosure, replace the asterisk (*) with an R.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bosch Voice Evacuation Systems | 7  
EVAX Expansion Panels - E models (without DMR, with microphone)  
Consists of  
Consists of  
Consists of  
Model  
Model  
Model  
EVAX25E*  
1
1
EVAX50E*  
1
1
EVAX100M*  
1
1
Consists of  
Consists of  
Model  
Model  
EVAX150E*  
1
1
EVAX200E*  
1
1
* The asterisk (*) is not part of the number; it is a placeholder for indicating the color option. For a charcoal gray  
enclosure, drop the asterisk (*). For a red enclosure, replace the asterisk (*) with an R.  
Ordering Information  
Ordering Information  
EVAX25R 25 W Amplifier with DMR and  
Microphone (red cabinet)  
25 W amplifier with a digital message repeater  
and a microphone in a standard (45.7 cm x  
36.2 cm x 10.2 cm [18 in. x 14.25 in. x 4 in.])  
red cabinet.  
EVAX24R  
EVAX50R/4Z 50 W, Four‑zone Amplifier  
with DMR and Microphone (red cabinet)  
50 W amplifier with one EVX‑4Z Zone Splitter,  
a digital message repeater, and a microphone  
in a standard (45.7 cm x 36.2 cm x 10.2 cm  
[18 in. x 14.25 in. x 4 in.]) red cabinet  
EVAX50R/4Z  
EVAX25R/4Z 25 W, Four‑zone Amplifier  
with DMR and Microphone (red cabinet)  
25 W amplifier with one EVX‑4Z Zone Splitter,  
a digital message repeater, and a microphone  
in a standard (45.7 cm x 36.2 cm x 10.2 cm  
[18 in. x 14.25 in. x 4 in.]) red cabinet  
EVAX25R/4Z  
EVAX25R/8Z  
EVAX50R  
EVAX50R/8Z 50 W, Eight‑zone Amplifier  
with DMR and Microphone (red cabinet)  
50WamplifierwithtwoEVX‑4ZZoneSplitters,  
a digital message repeater, and a microphone  
in a standard (45.7 cm x 36.2 cm x 10.2 cm  
[18 in. x 14.25 in. x 4 in.]) red cabinet  
EVAX50R/8Z  
EVAX25R/8Z 25 W, Eight‑zone Amplifier  
with DMR and Microphone (red cabinet)  
25WamplifierwithtwoEVX‑4ZZoneSplitters,  
a digital message repeater, and a microphone  
in a standard (45.7 cm x 36.2 cm x 10.2 cm  
[18 in. x 14.25 in. x 4 in.]) red cabinet  
Accessories  
D126 Standby Battery (12 V, 7 Ah)  
Sealed lead‑acid standby and auxiliary re-  
chargeable power supply.  
D126  
DFP-2 Large Dead Front Panel  
Charcoal gray panel fits a large cabinet or back  
box with door and comes with a lock and key  
DFP-2  
EVAX50R 50 W Amplifier with DMR and  
Microphone (red cabinet)  
50 W amplifier with a digital message repeater  
and a microphone in a standard (45.7 cm x  
36.2 cm x 10.2 cm [18 in. x 14.25 in. x 4 in.])  
red cabinet  
EVX-BB-2 Large Back Box  
EVX-BB-2  
Large charcoal-gray back box measures  
(HxWxD) 27 in. x 14.25 in. x 4 in. (68.6 cm x  
36.2 cm x 10.2 cm) and comes without a door  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 | Bosch Voice Evacuation Systems  
Ordering Information  
EVX-BB-2R Large Back Box  
EVX-BB-2R  
EVX-CAB-1  
EVX-CAB-1R  
EVX-CAB-2  
EVX-CAB-2R  
EVX-DR-2  
Large red back box measures (HxWxD) 27 in.  
x 14.25 in. x 4 in. (68.6 cm x 36.2 cm x  
10.2 cm) and comes without a door  
EVX-CAB-1 Standard Cabinet  
Charcoal-gray standard cabinet measures  
(HxWxD) 18 in. x 14.25 in. x 4 in. (45.7 cm x  
36.2 cm x 10.2 cm) and comes with a door  
EVX-CAB-1R Standard Cabinet  
Red standard cabinet measures (HxWxD)  
18 in. x 14.25 in. x 4 in. (45.7 cm x 36.2 cm x  
10.2 cm) and comes with a door  
EVX-CAB-2 Large Cabinet  
Large charcoal-gray cabinet measures  
(HxWxD) 27 in. x 14.25 in. x 4 in. (68.6 cm x  
36.2 cm x 10.2 cm) and comes with a door  
EVX-CAB-2R Large Cabinet  
Large red cabinet measures (HxWxD) 27 in. x  
14.25in. x4in. (68.6cmx36.2cmx10.2cm)  
and comes with a door  
EVX-DR-2 Large Door  
Charcoal-gray door fits a large cabinet or back  
box  
EVX-DR-2R Large Door  
Red door fits a large cabinet or back box  
EVX-DR-2R  
EVX-RM  
EVX-RM Remote Microphone  
Remote microphone in a charcoal-gray cabinet  
EVX-SC Microphone Supervisory Card  
EVX-SC  
supervises up to five remote microphones  
Americas:  
Europe, Middle East, Africa:  
Bosch Security Systems B.V.  
P.O. Box 80002  
5600 JB Eindhoven, The Netherlands  
Phone: + 31 40 2577 284  
Fax: +31 40 2577 330  
Asia-Pacific:  
Robert Bosch (SEA) Pte Ltd, Security Systems  
11 Bishan Street 21  
Singapore 573943  
Phone: +65 6258 5511  
Represented by  
Bosch Security Systems, Inc.  
130 Perinton Parkway  
Fairport, New York, 14450, USA  
Phone: +1 800 289 0096  
Fax: +1 585 223 9180  
Fax: +65 6571 2698  
© Bosch Security Systems Inc. 2010 | Data subject to change without notice  
T1125085707 | Cur: en-US, V5, 4 Jul 2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Network Card MDS932AE 10BT User Manual
Black Box Switch 724 746 5500 User Manual
Bogen Speaker System FS 2 User Manual
Bolens Lawn Mower 130 400 300 User Manual
Bosch Appliances Cooktop PGP976SET User Manual
Bosch Appliances Home Security System LTC 9083 01 User Manual
BOXLIGHT Projector XD 9m User Manual
BRK electronic Home Safety Product EL52W 2 User Manual
Carrier Furnace 58MCA User Manual
Cisco Systems Modem DPQ2202 User Manual