12
en | Installing a Pipe Mount
AUTODOME 5000 PTZ Camera
Pipe Mount Installation Instructions
Caution!
Strength of Mounting Surface
The fasteners and mounting surface must be capable of supporting a maximum load of
12 kg (26.4 pounds).
!
1. Locate a secure position to secure the Pipe Mount Base (1). Ensure there is an adequate
opening in the ceiling or mounting structure for the wires to pass through.
2. Use the Rubber Gasket as a template to mark the locations of the four ceiling plugs and
screws.
3. Insert the ceiling plugs (if necessary) into the wall at the locations marked in step 2.
4. Place the rubber pad between the Pipe Mount Base (1) and the ceiling. Secure the Pipe
Mount Base and the rubber pad to the ceiling or mounting structure with the four (4)
M10x25L screws and washers.
5. Apply Teflon tape to the threads on the Pipe Mount Base.
6. Apply Silicon grease over the Teflon tape on the threads on Pipe Mount Base. Ensure the
grease is spread evenly.
7. Determine the distance that the camera should hang from the ceiling or mounting
structure (200 mm, 300 mm, or 500 mm).
8. For the 200 mm or 300 mm option:
Select the appropriate Pipe Extension (3 or 5).
Fasten the Pipe Extension to the Pipe Mount Base (1).
Apply Teflon tape to both sets of threads on the M38 to M33 Connector (6).
Apply Silicon grease over the Teflon tape on both sets of threads on the M38 to M33
Connector (6). Ensure the grease is spread evenly.
Fasten the M38 to M33 Connector (6) to the bottom of the Pipe Extension.
9. For the 500 mm option:
Fasten the 300 mm Pipe Extension (3) to the Pipe Mount Base (1).
Apply Teflon tape to both sets of threads on the M38 to M38 Connector (4).
Apply Silicon grease over the Teflon tape on both sets of threads on the M38 to M38
Connector (4). Ensure the grease is spread evenly.
Fasten the M38 to M38 Connector (4) to the bottom of the 300 mm Pipe Extension. Then,
fasten the 200 mm Pipe Extension (5) to the other end of the M38 to M38 Connector.
Apply Teflon tape to both sets of threads on the M38 to M33 Connector (4).
Apply Silicon grease over the Teflon tape on both sets of threads on the M38 to M33
Connector (4). Ensure the grease is spread evenly.
Fasten the M38 to M33 Connector (6) to the bottom to the 200 mm Pipe Extension.
Notice!
Ensure that the Safety Tether (7) is routed through the Pipe Extensions and that the eyelet at
the end of the tether is through the M38 to M33 connector.
10. Fasten the Adaptor (8) to the bottom of the M38 to M33 connector.
11. Thread all connection cables from the top of the pipe mount base through the pipe
extensions and the adaptor.
12. Attach the hook at the end of the Safety Tether (7) to the loop attached to the top of the
Dome Camera (9).
13. Connect all cables to the camera back plate.
2013.07 | 1.3 |
Installation Guide
Bosch Security Systems, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.