Bosch Appliances Satellite Radio MIYN46 User Manual

MIYN46 Wall Transmitter  
970.035b | F.01U.278.521 | V2.0 | 2012.12  
en User Manual US  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MIYN46 Wall Transmitter  
| en  
3
Table of Contents  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MIYN46 Wall Transmitter  
Generalities | en  
5
1
Generalities  
1.1  
Resident Alert System  
Alarms and Messages arriving from Resident Alert System Transmitters such as the MIYN46  
Wall Transmitter are managed and stored by the Main Unit.  
1.2  
MIYN46 Wall Transmitter  
The MIYN46 Wall Transmitter is a multifunction terminal radio transmitter, designed for  
residents and staff to make an emergency call, summon assistance or cancel a call directly in  
the resident's room. It is part of a Resident Alert System, and is easily expandable.  
In the Resident Alert System, the MIYN46 Wall Transmitter allows the resident of an  
independent living or assisted living facility to easily alert the care personnel if needed. The  
resident simply has to push the large red button. The system is then able to control and to  
monitor the progress of the care personnel.  
The alarm and event transmission is performed by radio. There is no need for a wired  
connection between the MIYN46 Wall Transmitter and the Main Unit, this makes the system  
installation easy and allows great mobility.  
Depending on the model, two relay outputs are available and may be used to connect alarm  
and staff presence indicators such as, for instance, the signal lamps installed above the door.  
Two LED signal lamps allow the progress to be monitored on the device.  
In this document you will find all the information you need for the installation and the use of  
the MIYN46 Wall Transmitter.  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
6
en | Safety Instructions  
MIYN46 Wall Transmitter  
2
Safety Instructions  
WARNING!  
The User / Installer should read and understand this chapter before any intervention on the  
MIYN46 Wall Transmitter.  
!
2.1  
Introduction  
2.1.1  
Principle  
NOTICE!  
In case of unclear information, please contact your local representative.  
2.1.2  
Importance of safety instructions  
Each safety and protection instruction in this manual must be adhered to in order to avoid  
personnel injuries, property damages or environmental pollution.  
In a similar manner, the legal bylaws, the measures in prevention of accidents and for the pro-  
tection of the environment, as well as the recognized technical rules aiming at appropriate  
and safe working conditions which as applied in the country and at the place of use of the  
MIYN46 Wall Transmitter must be adhered to.  
2.1.3  
Disregarding safety rules  
Disregarding the safety rules, as well as existing legal and technical regulations, may lead to  
accidents, to property damages or to environmental pollution.  
2.2  
Environmental conditions  
WARNING!  
The MIYN46 Wall Transmitter must not be located near a water tap or any other source of  
water.  
The electrical safety of the MIYN46 Wall Transmitter is only guaranteed if the electrical instal-  
lation is in accordance with the national regulations and if this installation works properly.  
The MIYN46 Wall Transmitter may not be used in buildings prone to fire and explosion haz-  
ards.  
!
!
!
CAUTION!  
The MIYN46 Wall Transmitter may not be used under exposure to the direct sunlight, to heat,  
to dust or to an excessive humidity (only use the equipment in a clean environment).  
Install the MIYN46 Wall Transmitter in a dry place, away from any source of heat.  
CAUTION!  
Interferences  
Avoid immediate proximity to other electric devices such as a television.  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
MIYN46 Wall Transmitter  
Safety Instructions | en  
7
2.3  
General safety instructions  
DANGER!  
During maintenance operations, when the MIYN46 Wall Transmitter is powered and its casing  
is removed, the MIYN46 Wall Transmitter may not be left unattended.  
!
!
CAUTION!  
The MIYN46 Wall Transmitter may only be connected to the electrical sources as described in  
CAUTION!  
Maintenance and repairs may only be performed in accordance with the instructions and by  
authorized technical personnel only. The sole possession of the User Manual US does not  
allow the personnel to perform any kind of repair on the MIYN46 Wall Transmitter. Take into  
account all the warnings and follow all the instructions displayed on the MIYN46 Wall Trans-  
mitter and those which are printed in the documentation.Never try to use replacement pieces  
other than those authorized by the manufacturer of the MIYN46 Wall Transmitter.  
!
!
CAUTION!  
It is mandatory to use the products specified in the present User Manual US to clean the  
MIYN46 Wall Transmitter. If you plan to use another product, only do so after having obtained  
the authorization of the manufacturer.  
WARNING! Electro Static Discharge  
The MIYN46 Wall Transmitter contains highly sensitive electronic components. It should be  
opened only in an ESD protected environment with respect to the following precautions:  
Discharge yourself from electrostatic loads by touching a grounded conductive surface  
!
!
before opening the unit.  
Avoid touching conductive parts inside the MIYN46 Wall Transmitter if not absolutely nec-  
essary.  
CAUTION!  
Never let any liquid enter the system. In case of liquid spill inside the MIYN46 Wall Transmit-  
ter, act immediately as follows:  
1. Switch off the MIYN46 Wall Transmitter: take out the battery or remove the power supply.  
2. Dry up the MIYN46 Wall Transmitter.  
3. Clean the MIYN46 Wall Transmitter.  
4. Check its electrical functions.  
2.3.1  
Observation and information  
In case of defective operation or any other technical incident for which no remedy is  
described in this manual, please contact immediately your local representative.  
2.4  
Special safety instructions  
Appropriate safety instructions linked to specific risks are described in the corresponding  
section of this manual.  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
8
en | Description  
MIYN46 Wall Transmitter  
3
Description  
3.1  
General description  
3.1.1  
Top view  
Fig. 3.1 Top view  
1. Red emergency call button  
2. LED indicator for alarm  
3. LED indicator for presence  
4. Green acknowledgment button, to acknowledge an alarm locally.  
5. Blue assistance call button  
6. Socket for coded key insertion (option)  
7. Installation compartment  
8. Jack plug for pear-push button  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
MIYN46 Wall Transmitter  
Description | en  
9
3.2  
Main functions  
The main function of the MIYN46 Wall Transmitter is to enable easier handling of emergencies  
and help, directly from the resident’s room.  
3.2.1  
3.2.2  
3.2.3  
3.2.4  
Red emergency call button  
Its large red button with textured surface makes it easy to identify and to press, launching an  
emergency call.  
Blue assistance call button  
If, upon arriving, the staff requires additional help, a call for assistance can be sent by  
pressing the round blue button.  
Green acknowledgment button  
In all cases, there is an automatic call repetition until cancel of the call. Cancelling can be  
made directly on the room transmitter with the smaller green button.  
Alarm signaling  
The presence and alarm LED indicators enhance the signaling of alarms.  
The MIYN46 Wall Transmitter is easily expandable, as a socket for pear-push button is directly  
accessible.  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
10 en | Installation  
MIYN46 Wall Transmitter  
4
Installation  
4.1  
Unpacking  
The MIYN46 Wall Transmitter is carefully packed for transportation. The components con-  
tained in the box are protected, but should be handled with care. Store the packaging mate-  
rial for further use (storage or transport).  
NOTICE!  
In case of defective or missing equipment, do not try to install the MIYN46 Wall Transmitter.  
Contact immediately your local representative.  
1. Take the components out of the box and place the MIYN46 Wall Transmitter in front of  
you.  
2. Check each component in the box, in accordance with the list of contents below.  
3. Check that the MIYN46 Wall Transmitter and its accessories have not been damaged dur-  
ing transportation.  
4.1.1  
List of contents  
Description  
MIYN46 Wall Transmitter  
2 screws  
2 screw anchors  
1 CR2450 3V Lithium battery  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
MIYN46 Wall Transmitter  
Installation | en  
11  
4.2  
Installation  
4.2.1  
Generalities  
Install the MIYN46 Wall Transmitter in a dry place, away from any source of heat.  
CAUTION!  
Interferences.  
!
Avoid immediate proximity to other electric devices such as a television.  
4.2.2  
Wall installation  
The MIYN46 Wall Transmitter can be fixed with two to five screws on a wall. Two holes at 2.4  
inches (60 mm) interval are provided for direct mounting on connection boxes. The three  
upper holes are used for positioning the device and cannot be reached from the installation  
compartment.  
3.4 in (80 mm)  
2.2 in (53.8 mm)  
0.51 in  
(13.1 mm)  
0.15 in  
(3.7 mm)  
0.63 in (16 mm)  
0.26 in (6.6 mm)  
1.06 in (27 mm)  
5.16 in (131 mm)  
2.36 in (59.9 mm)  
0.71 in (18.1 mm)  
1.62 in  
(26 mm)  
0.15 in  
(3.7 mm)  
0.08 in  
(2 mm)  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
12 en | Installation  
MIYN46 Wall Transmitter  
4.2.3  
Connecting to the power supply  
The MIYN46 Wall Transmitter can be powered by a lithium battery or/and an external 12-24  
VDC power supply. If the device is powered with an external power supply, the battery is not  
necessary, but it can be used as a backup power supply in case of power loss.  
If the device is powered by the battery only, the battery life is about 2 years. However, it is  
recommended to change the battery once a year.  
If the device is powered by an external power supply and the battery is used as backup power  
supply, it is recommended to check it at regular intervals (for instance once a year) and to  
change it if necessary.  
CAUTION!  
When powering the device, the external 12-24 VDC power supply must be equipped with a  
setting off safety device, that is easy to access. The power supply must also be equipped with  
a safety fuse of lower value, e.g. 100 or 125 mA.  
!
4.2.4  
Reset  
All parameters are reset when powering up the device (battery or external power supply). This  
operation causes the synchronization of the daily message.  
In order to perform a reset, make sure to remove both the battery and the external power sup-  
ply, make a short-circuit on the two pins marked Reset before powering the device up again.  
NOTICE!  
All connections as well as the configuration need to be carried out before powering the device  
(insertion of the battery and/or application of the external power supply).  
4.2.5  
Transmitter Identification  
All MIYN46 Wall Transmitters are provided with their own radio identification code that is  
assigned in the factory. During the installation, it is necessary to set the relationship between  
the identification code of the Transmitter and the place where it is installed (floor/room/bed  
or single number). This identification is programmed on the Main Unit (refer to the Main Unit  
User Manual).  
4.2.6  
Operation Check  
Once the transmitter has been installed and setup properly, it is recommended to check all  
functionalities of the device. The radio transmission can be checked by sending an acknowl-  
edgement call by pressing the green button.  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
MIYN46 Wall Transmitter  
Installation | en  
13  
4.2.7  
Replacing the battery  
WARNING!  
May explode if exposed to fire;  
Use only original batteries intended for use with your MIYN46 Wall Transmitter. Using  
other type of batteries could be dangerous;  
Do not expose the battery to liquids;  
Do not let the metal contacts on the battery touch another metal. This could damage the  
battery;  
Do not disassemble or modify the battery;  
!
!
Do not expose the battery to extreme temperatures, and never above 60 ºC (+140 ºF).  
For maximum battery capacity, use the battery at room temperature;  
Keep out of reach of children;  
Use the battery for the intended purpose only;  
Do not allow the battery to be put into the mouth. Battery electrolytes may be toxic if  
swallowed.  
CAUTION!  
There is a risk of explosion if battery is replaced by a wrong type or if not connected correctly.  
The battery should be replaced exclusively by Authorized Personnel.  
Dispose of used batteries according to instructions and regulations.  
Battery type is 3V CR2450/DL2450.  
Procedure  
1. Open the compartment cover (1) by sliding it downwards and then towards you.  
2. Carefully remove the used battery (2).  
3. Place the new battery. The positive terminal must be facing you.  
4. Replace the compartment cover.  
2
1
Fig. 4.1 Replacing the battery  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
14 en | Installation  
MIYN46 Wall Transmitter  
4.2.8  
Configuration and Wiring  
Solder Bridges (if soldered):  
B8 Call for Assistance only by Staff Presence  
B7 Call for Assistance from terminals J6[4-5]  
B6 No Staff Presence processing  
B5 No Daily Message  
B4 Not used  
B3 Not used  
B1(o) REL 1 Call for Help polarity  
B2(o) REL 2 Staff Presence polarity  
Terminal J5  
1 External 12-24 VDC power supply  
2 GND (0 V)  
3-4 REL 1 Call for Help  
5-6 REL 2 Staff Presence  
N
NC  
N
NC  
Connector J7:  
Presence / Staff identification (optional)  
J5  
1 2 3 4 5 6  
Terminal J6:  
CR 2450  
battery  
Reset  
4-5 Reserve Call or Call for Assistance  
3-4 Technical Alarm  
N
NC  
1-2 Call for Help  
J4  
5 4 3 2 1 J6  
J1 External Call for Help trigger  
input polarity  
Connector J4:  
External Call for Help  
trigger (pear push button)  
J2 Polarity of Technical Alarm input  
J3 Polarity of terminal J6[4-5] input  
(o)  
Solder bridges B1 and B2 are located on the bottom side of the PCB:  
NC-B2-NO NC-B1-NO  
Fig. 4.2 Configuration and Wiring  
NOTICE!  
Setting up one or more inputs to "NC" position results to higher power consumption. This con-  
figuration should be used with external power supply or will reduce the battery life.  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
MIYN46 Wall Transmitter  
Installation | en  
15  
4.3  
4.4  
Inputs and Outputs  
General inputs  
The * marks a factory setting.  
External trigger J4  
Jack  
J1  
NO* Closing contact causes a Call for Help  
Contact opening causes a Call for Help  
NC  
Power supply  
J5  
1
2
+
-
12 to 24 V DC  
GND 0V  
4.5  
Wired Outputs  
Call for Help  
Relay  
J5  
3-4  
5-6  
B1  
B2  
NO* A Call for Help causes the closing of  
the relay contact  
NC  
A Call for Help causes the opening of  
the relay contact  
Staff Presence J5  
Relay  
NO* Staff Presence signaling causes the  
closing of the relay  
NC  
Staff Presence signaling causes the  
opening of the relay  
4.6  
Wired Inputs  
Call for Help  
J6  
1-2  
3-4  
The contact closing causes a Call for  
Help.  
Technical  
Alarm  
J6  
J2  
J3  
NO* The contact closing causes a Technical  
Alarm  
NC  
The contact opening causes a Techni-  
cal Alarm  
Reserve Call or J6  
Call for Assis-  
tance  
4-5  
NO* The contact closing causes a Reserve  
Call or a Call for Assistance  
NC  
The contact opening causes a Reserve  
Call or a Call for Assistance  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
16 en | Installation  
MIYN46 Wall Transmitter  
4.7  
General configuration  
The * marks a factory setting.  
Bridge State  
Function  
B3  
B4  
B5  
Open*  
Technical Alarms are not repeated.  
Soldered* Calls are not repeated.  
Open*  
A daily message is sent every 24 hours.  
Soldered  
Daily messages are suppressed.  
(o)  
B6  
Staff Presence Processing is activated.  
Open  
(o)  
Staff Presence Processing is disabled.  
Soldered  
Open*  
B7  
B8  
Activation of J6 [4-5] terminal input causes a Reserve Call.  
Soldered  
Open*  
Activation of J6 [4-5] terminal input causes a Call for Assistance.  
The Assistance Call does not depend on the presence of the Care Per-  
sonnel.  
Soldered  
The Assistance Call is possible only if the Care Personnel has signaled  
his/her presence.  
(o)  
MIYN46 Wall Transmitters that feature the output relays are delivered with the Staff Pres-  
ence Processing activated (B6 open). Models that do not feature the output relays are deliv-  
ered with the Staff Presence Processing disabled (B6 soldered).  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
MIYN46 Wall Transmitter  
Use | en  
17  
5
Use  
Every time a MIYN46 Wall Transmitter is used by pressing a button or activating a wired input,  
the device sends a radio signal and the lamps indicates its actual state. Optionally, two relays  
allow the transmission of status to a remote display such as the signal lamps placed on top of  
the door.  
Each radio message is sent with a different code which allows the receiver (Resident Alert  
System) to recognize the performed action.  
NOTICE!  
It is recommended to keep the button pressed until the lamp placed above the red button  
lights up.  
5.1  
Call for Help  
The Call for Help can be triggered in three different ways:  
by pushing the red Call for Help button  
by pushing the external switch connected to the J4 connector, for example a pear  
push button.  
by pushing the external button connected to terminals 1 & 2 of the terminal block  
J6.  
The Call for Help is repeated approximately every 2 minutes until a call acknowledgement  
takes place, up to a maximum of 20 minutes. This repeat function can be disabled by setting  
the solder bridge B4.  
A Call for Help is signaled by red flashes on the signal lamp and optionally, by the activation of  
the relay Call for Help.  
NOTICE!  
In some cases, the action Call for Help generates a Call for Assistance action. See  
5.2  
Call for Assistance  
The Call for Assistance is triggered by pushing the Call for Assistance button (blue).  
The Call for Assistance is repeated approximately every 2 minutes until a call acknowledge-  
ment takes place, up to a maximum of 20 minutes. This repeat function can be disabled by  
setting the solder bridge B4.  
A Call for Assistance is signaled by red double flashes on the signal lamp and by the alternate  
action/release of the relay Call for Help.  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
18 en | Use  
MIYN46 Wall Transmitter  
5.3  
Call Acknowledgement (Staff Presence)  
The call acknowledgement is triggered by pushing the Acknowledgement button (green).  
The call acknowledgement stops immediately all repetitions of the calls.  
Optionally, a call acknowledgement triggers the Staff Presence signal:  
by green flashes on the signal lamp and by activating the Staff Presence relay when  
the Caregiver pushes the Acknowledgement button when entering the room.  
by switching off the lamp and releasing the Staff Presence relay when the Caregiver  
pushes the Acknowledgement button and leaves the room.  
5.4  
Reserve Call  
The Reserve Call is triggered by pushing the external button connected to terminals 4 and 5 of  
the terminal block J6.  
The call can be triggered by closing (NO) or opening (NC) the contact.  
The Reserve Call is repeated about every 2 minutes until a call acknowledgement takes place,  
up to a maximum of 20 minutes. This repeat function can be disabled by setting the solder  
bridge B4.  
The Reserve Call is signaled in the same way as the Call for Help on the signal lamp and the  
relays.  
5.5  
Technical Alarm  
The Technical Alarm is triggered by activating the contact connected to terminals 3 and 4 of  
the terminal block J6.  
The alarm can be triggered by closing (NO) or opening (NC) the contact 3.  
Normally, the Technical Alarm is not repeated, but it is possible to activate the repetition of  
the technical alarms by setting the solder bridge B3. In this case, the Technical Alarm is  
repeated about every 2 minutes until a call acknowledgement takes place, up to a maximum of  
20 minutes.  
The Technical Alarm is signaled in the same way as the Call for Help on the signal lamp and the  
relays.  
5.6  
Caregiver Arrival  
The Caregiver Arrival message is triggered when the Caregiver inserts the coded key in the  
connector on the side of the housing (J7), when entering the room. This message will appear  
if the optional coded key function is available on the device.  
Up to four categories of Caregivers may be identified by using different keys.  
The Caregiver Arrival message is not repeated.  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
MIYN46 Wall Transmitter  
Use | en  
19  
Insertion of the coded key is signaled by green flashes on the signal lamp and by activating the  
Staff Presence relay.  
5.7  
Caregiver Departure  
The Caregiver Departure message is triggered when the Caregiver removes the coded key  
from the housing, when leaving the room.  
The Caregiver Departure message is not repeated.  
Removing the coded key is signaled by switching off the green flashes on the signal lamp and  
by releasing the Staff Presence relay.  
5.8  
5.9  
Daily Message and Battery Low Message  
The radio transmission can be checked by way of the daily message which is automatically  
sent about every 24 hours. When the battery voltage is too low, the daily message is replaced  
by a Battery Low message. The duration of the daily message is 1.7 seconds.  
The transmission of the Daily Message can be disabled by setting the solder bridge B5 (this  
does not influence the transmission of the Battery Low message).  
Error Message  
The Error Message is sent one time if the device has detected a general dysfunction, or if one  
of the following triggering devices remains in its activated position for up to 4 minutes:  
Call for Help  
Acknowledgement button  
Call for Assistance  
Reserve Call  
NOTICE!  
The device connected to the Technical Alarm input is allowed to remain in the activated posi-  
tion; without transmission of the Error Message.  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
20 en | Operation  
MIYN46 Wall Transmitter  
6
Operation  
6.1  
Description of the six different states  
During operation, the MIYN46 Wall Transmitter can be set to one of six following states:  
State  
Description  
Stand-by  
No call is being processed.  
Alarm without staff presence  
The resident has triggered a Call for Help but the Care  
Personnel has not yet responded.  
Alarm with staff presence  
The Care Personnel has responded after a Call for Help.  
Assistance without staff presence  
A Call for Assistance has been triggered without the  
presence of the Care Personnel.  
Assistance with staff presence  
Staff Presence without alarm  
A Call for Assistance has been triggered in the presence  
of the Care Personnel.  
The Care Personnel has responded without a previous  
call from the resident.  
Each state is indicated by the signal lamp and by a special position of the output relays.  
It is possible to configure the MIYN46 Wall Transmitter in order that:  
the Call for Assistance can be triggered only if the Care Personnel is present.  
the device does not manage the Staff Presence. This mode makes sense only if the  
output relays are not provided or not used.  
The transition to a specific condition depends on the device configuration, of its actual condi-  
tion and of the action completed; as shown on the charts in the following chapters.  
NOTICE!  
When the MIYN46 Wall Transmitter is powered by an external power supply, the signal lamps  
follow the state of the corresponding relay outputs.  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
MIYN46 Wall Transmitter  
Operation | en  
21  
6.2  
Legend of illustrations  
Description  
Legend  
The contact of the Call for Help relay is closed  
The contact of the Call for Help relay is open  
The contact of the Call for Help relay opens and closes alternately  
The contact of the Staff Presence relay is closed  
The contact of the Staff Presence relay is open  
The signal lamps are off  
A signal lamp lights up in the indicated color  
A signal lamp flashes in the indicated color  
A signal lamp flashes quickly in the indicated color  
Table 6.1  
6.3  
Operation with the staff presence processing activated  
6.3.1  
Device behavior when pressing a button  
State before action: Stand-by  
Signal lamp  
Radio Message  
Action  
State  
Relay contact  
(none)  
Stand-by  
Alarm without staff  
presence  
Call for Help  
Call for Help  
Call  
Staff presence  
Acknowledgement without alarm  
Acknowledgement  
Call for Assistance  
Assistance without  
staff presence **  
Call for Assistance  
** If the function Assistance only in case of Staff Presence is activated and the MIYN46 Wall  
Transmitter is not in Staff presence state, the Call for Assistance causes a state Alarm without  
Staff Presence and a Call for Help radio message.  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
22 en | Operation  
MIYN46 Wall Transmitter  
State before action: Alarm without staff presence  
Signal lamp  
Radio Message  
Action  
State  
Relay contact  
Alarm without staff  
presence  
(none)  
Alarm without staff  
presence  
(unchanged)  
Call for Help  
Call for Help  
Call  
Alarm with staff  
Acknowledgement presence  
Acknowledgement  
Assistance without  
staff presence **  
Call for Assistance  
Call for Assistance  
**If the function Assistance only in case of Staff Presence is activated and the MIYN46 Wall  
Transmitter is not in Staff presence state, the Call for Assistance causes a state Alarm without  
Staff Presence and a Call for Help radio message.  
State before action: Alarm with staff presence  
Signal lamp  
Radio Message  
Action  
State  
Relay contact  
Alarm with staff  
presence  
(none)  
Assistance with staff  
presence  
Call for Assistance  
Acknowledgement  
Call for Assistance  
Call for Help  
Call  
Stand-by  
Acknowledgement  
Assistance with staff  
presence  
Call for Assistance  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
MIYN46 Wall Transmitter  
Operation | en  
23  
State before action: Assistance with staff presence  
Signal lamp  
Signal lamp  
Signal lamp  
Radio Message  
Action  
State  
Relay contact  
Assistance with staff  
presence  
(none)  
Assistance with staff  
presence  
(unchanged)  
Call for Assistance  
Acknowledgement  
Call for Assistance  
Call for Help  
Call  
Alarm with staff  
Acknowledgement presence  
Assistance with staff  
presence  
Call for Assistance  
State before action: Assistance without staff presence  
Radio Message  
Action  
State  
Relay contact  
Assistance without  
staff presence  
(none)  
Assistance without  
staff presence  
(unchanged)  
Call for Assistance  
Acknowledgement  
Call for Assistance  
Call for Help  
Call  
Alarm with staff  
Acknowledgement presence  
Assistance without  
staff presence  
Call for Assistance  
State before action: Staff presence without alarm  
Radio Message  
Action  
State  
Relay contact  
Staff presence  
without alarm  
(none)  
Alarm with staff  
presence  
Call for Help  
Call for Help  
Call  
Acknowledgement  
Stand-by  
Acknowledgement  
Assistance with staff  
presence  
Call for Assistance  
Call for Assistance  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24 en | Operation  
MIYN46 Wall Transmitter  
6.4  
Operation with the staff presence processing deactivated  
6.4.1  
Device behavior upon pressing a button  
State before action: Stand-by  
Signal lamp  
Radio Message  
Action  
State  
Relay contact  
(none)  
Stand-by  
Alarm without staff  
presence  
Call for Help  
Call for Help  
Call  
Acknowledgement  
Stand-by  
Acknowledgement  
Assistance without  
staff presence *  
Call for Assistance  
Call for Assistance  
State before action: Alarm without staff presence  
Signal lamp  
Radio Message  
Action  
State  
Relay contact  
Alarm without staff  
presence  
(none)  
Alarm without staff  
presence  
Call for Help  
Call for Help  
(unchanged)  
Call  
Acknowledgement  
Stand-by  
Acknowledgement  
Assistance without  
staff presence *  
Call for Assistance  
Call for Assistance  
State before action: Assistance without staff presence  
Signal lamp  
Radio Message  
Action  
State  
Relay contact  
Assistance without  
staff presence  
(none)  
Assistance without  
staff presence  
(unchanged)  
Call for Assistance  
Acknowledgement  
Call for Assistance  
Call for Help  
Call  
Stand-by  
Acknowledgement  
Assistance without  
staff presence  
Call for Assistance  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
MIYN46 Wall Transmitter  
Storage | en  
25  
7
Storage  
One can distinguish between long term storage and short term storage.  
If the MIYN46 Wall Transmitter must be temporarily stored, it may not be necessary to wrap it  
completely.  
However, if you wish to store the MIYN46 Wall Transmitter for a longer time, for instance in a  
storage room or any similar location, it is recommended to use original packing material.  
7.1  
Short term storage conditions  
Unwrapped MIYN46 Wall Transmitter in a room:  
Protection against direct sunlight and dust.  
7.2  
Long term storage conditions  
NOTICE!  
The MIYN46 Wall Transmitter does not loose its programmed parameters when the power sup-  
ply and the backup battery are disconnected.  
MIYN46 Wall Transmitter in its original packing material in a storage room:  
Backup battery removed;  
Protection against direct sunlight and dust.  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
26 en | Disposal  
MIYN46 Wall Transmitter  
8
Disposal  
This chapter describes the appropriate disposal of the MIYN46 Wall Transmitter.  
The MIYN46 Wall Transmitter is marked with a crossed-out wastebasket symbol.  
This means that, at the end of its useful lifespan, the product shall be disposed separately  
from ordinary household wastes in accordance to the local directives.  
The product and its accessories shall be delivered to an appropriate collection facility that will  
permit recycling, treatment and environmentally compatible disposal. This will prevent nega-  
tive impact on the environment and human health and promotes the recycling of materials.  
For more information on available collection facilities, contact your local waste collection ser-  
vice or your local representative.  
8.1  
8.2  
Disassembly  
Only authorized personnel are allowed to disassemble a MIYN46 Wall Transmitter.  
Local disposal locations  
The nearest disposal locations are established in accordance with the currently applicable  
laws. Ask the local authorities.  
8.3  
8.4  
Returning to the manufacturer  
If there is no practical disposal place, the MIYN46 Wall Transmitter may be returned to your  
local representative.  
Materials  
The MIYN46 Wall Transmitter must be returned to an authorized point of recycling.  
In order to protect people and environment, the MIYN46 Wall Transmitter must be recycled in  
an adequate manner. Consequently, all applicable laws and bylaws must be respected.  
8.4.1  
Battery  
NOTICE!  
The battery should never be placed in municipal waste. Use a battery disposal facility if avail-  
able.  
Fig. 8.1 Crossed-out wastebasket symbol  
Please check local regulations for disposal of batteries or call your local representative  
for information.  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
User Manual US  
Bosch Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
MIYN46 Wall Transmitter  
Appendix | en  
27  
9
Appendix  
9.1  
Electrical specifications  
External power supply  
& consumption  
12-24 VDC  
Transmission: < 40 mA  
Idle mode: < 10 mA  
Battery power supply  
& consumption  
3V lithium battery CR2450  
Transmission: < 30 mA  
Idle mode: < 10 µA  
Battery life  
Approx. 2 years  
Table 9.1 Electrical specifications  
9.2  
Dimensions and weight  
Casing dimensions  
Depth  
[in]  
1
[mm]  
26  
Width  
3.2  
5.2  
[oz]  
7
82  
Height  
132  
[g]  
200  
Casing weight  
Weight  
(including antenna and power supply adaptor)  
Table 9.2 Dimensions and weight  
9.3  
9.4  
Operating temperature  
Operating temperature  
32 °F - 131 °F (0 °C - 55 °C)  
Table 9.3 Environmental conditions  
FCC warning statement  
This equipment complies with Part 15 of the FCC rules. Any changes or modifications not  
expressly approved by the manufacturer could void the user's authority to operate the equip-  
ment.  
This device complies with Part 15 of the FCC rules subject to the following two conditions:  
1. This device may not cause harmful interference  
2. This device must accept all interference received, including interference that may cause  
undesired operation.  
Bosch Security Systems  
User Manual US  
970.035b | F.01U.278.521 | v2.0 | 2012.12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Robert Bosch Healthcare Systems, Inc.  
2400 Geng Road, Suite 200  
Palo Alto, CA 94303  
U.S.A.  
Phone: 650-690-9100  
Toll Free: 1-888-947-8957  
Fax: 650-798-3770  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Beko Ventilation Hood HBV60X User Manual
Belkin Automobile Accessories F8V7058 APL User Manual
Bionaire Humidifier BCM646 User Manual
Bradford White Corp Water Heater 25X 78B 3N User Manual
Bradford White Corp Water Heater BMT2H User Manual
Campbell Hausfeld Grinder Grinder User Manual
Canon Projector LV7291M User Manual
Casio Cash Register PCRT220S User Manual
Chamberlain Home Security System 935CB User Manual
Chrysler Automobile 2005 Pacifica User Manual