Bosch Appliances Home Security System LTC 5136 User Manual

LTC 5136 Series  
Installation Instructions  
EN AutoDome®  
ontrollers  
C
F.01U.284.614  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | FCC Information  
EN  
3
17. Damage Requiring Service - Unplug the unit from  
the outlet and refer servicing to qualified service  
personnel under the following conditions:  
a. When the power supply cord or plug is  
damaged.  
FCC & ICES Information  
(U.S.A. and Canadian Models Only)  
This device complies with part 15 of the FCC  
Rules.  
Operation is subject to the following two conditions:  
(1) This device may not cause harmful interference,  
and  
b. If liquid has been spilled or objects have fallen  
into the unit.  
(2) This device must accept any interference  
received, including interference that may cause  
undesired operation.  
c. If the unit has been exposed to water and/or  
inclement weather (rain, snow, etc.).  
d. If the unit does not operate normally by  
following the operating instructions. Adjust only  
those controls that are covered by the operating  
instructions, as an improper adjustment of other  
controls may result in damage and will often  
require extensive work by a qualified technician  
to restore the unit to its normal operation.  
e. If the unit has been dropped or the cabinet has  
been damaged.  
NOTE: This equipment has been tested and found to  
comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC Rules and ICES-003 of  
Industry Canada. These limits are designed to provide  
reasonable protection against harmful interference  
when the equipment is operated in a commercial  
environment. This equipment generates, uses and  
radiates radio frequency energy, and if not installed  
and used in accordance with the instruction manual,  
may cause harmful interference to radio  
f. When the unit exhibits a distinct change in  
performance--this indicates a need for service.  
18. Replacement Parts - When replacement parts are  
required, be sure the service technician has used  
replacement parts specified by the manufacturer  
or have the same characteristics as the original  
part. Unauthorized substitutions may result in fire,  
electric shock, or other hazards.  
communications. Operation of this equipment in  
a
residential area is likely to cause harmful interference,  
in which case the user will be required to correct the  
interference at his expense.  
Intentional or unintentional changes or modifications,  
not expressly approved by the party responsible for  
compliance, shall not be made. Any such changes or  
modifications could void the user’s authority to operate  
the equipment. If necessary, the user should consult the  
dealer or an experienced radio/television technician for  
corrective action.  
19. Safety Check - Upon completion of any service or  
repairs to this unit, ask the service technician to  
perform safety checks to determine that the unit is  
in proper operating condition.  
20. Coax Grounding - If an outside cable system is  
connected to the unit, be sure the cable system is  
grounded. U.S.A. models only--Section 810 of the  
National Electrical Code, ANSI  
/
N
F
P
A
No.70,  
THIS IS A CLASS A PRODUCT. IN  
ENVIRONMENT, THIS PRODUCT MAY CAUSE  
INTERFERENCE, IN CASE, THEUSER MA  
BE REQUIRED TO TAKE ADEQUATE ME URES.  
A
DOMESTIC  
provides information with respect to proper  
grounding of the mount and supporting structure,  
grounding of the coax to a discharge unit, size of  
grounding conductors, location of discharge unit,  
connection to grounding electrodes, and  
R
ADIO  
WH  
I
C
H
Y
AS  
The user may find the following booklet, prepared by  
the Federal Communications Commission, helpful:  
How to Identify and Resolve Radio-TV Interference  
Problems. This booklet is available from the U.S.  
requirements for the grounding electrode.  
21. Lightning - For added protection of this unit during  
a
lightning storm, or when it is left unattended and  
unused for long periods of time, unplug it from the  
wall outlet and disconnect the cable system. This  
will prevent damage to the unit due to lightning  
and power line surges.  
Government Printing Office, Washington, DC 20402  
Stock No. 004-000-00345  
,
-
4.  
Bosch Security Systems | 08 May 2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | Safety Precautions  
EN  
4
Safety Precautions  
CAUTION: TO REDUCE THE RISK OF  
ELECTRIC  
(OR BACK). NO USER SERVICEABLE PARTS  
INSID REFER SERVICING TO QUALIFIED  
SERVICE PERS NNEL  
S
H
O
C
K
,
DO NOT REMOVE COVER  
E
.
O
.
The lightning flash with an arrowhead  
symbol, within an equilateral triangle, is  
intended to alert the user to the  
presence of uninsulated “dangerous  
voltage” within the product’s enclosure  
that may be of sufficient magnitude to  
constitute a risk of electric shock to  
persons.  
The exclamation point within an  
equilateral triangle is intended to alert  
the user to presence of important  
operating and maintenance  
instructions in the literature  
(servicing)  
accompanying the appliance.  
Attention: Installation should be performed by  
qualified service personnel only in accordance  
with the National Electrical Code or applicable  
local codes.  
To meet the Mains Supply Voltage Dips and Short  
Interruptions requirements per EN 50130-4 Alarm  
Standard, ancillary equipment (for example, UPS) is  
necessary. The UPS must have a Transfer time  
between 2-6 ms and Backup Runtime of greater than  
5 seconds for the power level as specified on the  
product data sheet.  
Power Disconnect. Units with or without ON  
-
OFF switches have power supplied to the unit  
whenever the power cord is inserted into the  
power source; however, the unit is operational  
only when the ON-OFF switch is in the ON  
position. The power cord is the main power  
disconnect for all units.  
Bosch Security Systems | 08 May 2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | Contents  
EN  
5
Table of Content  
s
Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2  
FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2  
1
UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
2
3
3.1  
4
4.1  
4.2 Installation using Biphase Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
4.3 Installation using RS-232 Data Direct to Camera Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8  
4.4 Installation using an RS-232 Data Transmission Link to a Biphase Camera Site . . . . . . . . . . . . . . .9  
4.5  
5
AutoDome Camera or Receiver/Driver Site Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
SETTING FAST ADDRESS FEATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
CONTROLLER OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
Controls/Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
TECHNICAL REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
DATA CONVERTER PINOUTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
0
0
6
1
6.1  
7
1
3
8
6
Bosch Security Systems | 08 May 2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | Unpacking  
EN  
6
1
UNPACKING  
3
DESCRIPTION  
This electronic equipment should be unpacked and  
handled carefully  
The LTC 5136 Series Controllers are designed for use  
with the Bosch AutoDome Series cameras. They can  
also be used to operate any of the conventional  
Allegiant® Series of Receiver/Drivers.  
.
Check for the following items:  
LTC 5136/61 or LTC 5136  
ontroller  
/
51  
Desktop  
The LTC 5136 Series controllers support control of all  
AutoDome and Allegiant receiver/driver functions  
including variable speed pan/tilt/zoom, pre-positions,  
auxiliaries, etc. Typically, one of the 16 outputs of the  
LTC 5136 junction box is connected to a single  
C
.
Interface unit.  
Power supply  
Power supply cable.  
.
AutoDome camera or receiver/driver. If the application  
will use a daisy hain wiring configuration, up to eight  
c
One (1) 3 m (10 ft) cable with two (2)  
connectors.  
RJ-11  
(8) camera sites can be controlled from each of the 16  
biphase outputs.  
If an item appears to have been damaged in shipment,  
replace it properly in its carton and notify the shipper  
If any items are missing, notify your Bosch ecurity  
Systems, Inc. Sales Representative or Customer  
ervice.  
The biphase control code cable can extend  
a
.
maximum distance of 1.5 km (5000 ft), using  
1.0 mm2 (18 AWG) shielded twisted pair cable  
(Belden 8760 or equivalent).  
S
S
The shipping carton is the safest container in which the  
unit may be transported. Save it for possible future use.  
3.1  
Power  
The model number and operating voltage are shown  
on the product label.  
2
SERVICE  
Voltage  
Range  
Power at  
Rated oltage  
Model No  
.
Rated Voltage  
V
If the unit ever needs repair service, the customer should  
contact the nearest Bosch Security Systems, Inc. Service  
Center for authorization to return and shipping  
instructions.  
LTC 5136/51  
LTC 5136/61  
230 VAC, 50/60 Hz  
120 VAC, 50/60 Hz  
195.5 to 253  
105 to 132  
6
6
W
W
Service Centers  
U.S.A.: Phone: 800-366-2283 or 408  
-
956-3895  
800-366-1329 or 408-956 3896  
ationalServiceC[email protected].com  
514-738-2434  
Europe, Middle East & Asia Pacific  
2-1-440-0711  
fax:  
-
e-mail:  
N
Canada:  
Region:  
3
For additional information,  
see www.boschsecuritysystems.com.  
NOTE: Grounded wrist straps must be worn and  
proper ESD safety precautions observed when  
handling the electrostatic-sensitive printed circuit  
boards.  
Bosch Security Systems | 08 May 2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | Installation  
EN  
7
4.2 Installation Using Biphase Code  
4
INSTALLATION  
(See Figures 3 and  
4)  
4.1 General  
The desktop Controller unit should be installed in  
Install the supplied interface unit in a location close  
enough to the Controller unit so the that supplied  
3 m (10 ft) data cable can be used. Note that the  
interface unit is rated for indoor use only. If desired,  
a
location convenient to the operator. The  
Controller  
contains a single RJ-11 connector, which is used for  
both power and data connections. In most applications,  
the supplied 3 m (10 ft) power/data cable is connected  
directly to the supplied interface unit. The interface  
unit converts the RS-232 data generated by the  
Controller unit into Allegiant biphase control code.  
The interface unit also provides a path to connect  
power to the Controller unit.  
four holes are provided for mounting the interface unit  
to a flat surface. The power supply (to power the  
Controller and interface unit) should also be located in  
a convenient location near the interface unit.  
Connect  
the bayonet style connector of the power supply cable  
into the jack located on the side of the interface unit. If  
the power supply cable must be attached to the power  
supply, the polarity is not important; the Interface Unit  
An LED visible on the top cover of the interface unit  
will flash to indicate that the RS-232 data coming from  
the Controller has successfully been converted into  
biphase control code.  
is not polarity sensitive. Plug the power supply into  
suitable AC power source.  
a
Connect the supplied 3 m (10 ft) data cable with two  
RJ-11 connectors, between the Controller unit and the  
interface unit. The orientation is not important -- either  
end may be connected to either device.  
There are no video connections to the Controller. The  
video signal(s) from the camera site(s) should be  
connected to an appropriate viewing monitor, or other  
video processing equipment (switcher, multiplexer,  
etc.).  
The next step is to connect the biphase control code  
outputs of the interface unit to the data cables.  
Typically, a single camera site receiver/driver can be  
connected to each output, but the outputs of the  
If the application will utilize an RS-232 data  
communication link, or will be connected directly to  
RS-232 Series AutoDome cameras or RS-232 Allegiant  
Receiver/Driver units, the installation is done without  
interface unit are rated to handle up to eight (  
receiver/drivers when connected in a daisy hain  
configuration, to a maximum of 1.5 km (5000 ft). In  
daisy hain connection, the cable is looped through eac  
AutoDome camera or receiver/driver along the way  
The last (and only the last) unit in the daisy hain  
connection should be terminated. All other receiver/  
8)  
c
using the supplied interface unit. For  
R
S
-
232  
eyboard  
a
applications, an LTC 8557 Series Remote  
K
c
h
Hookup Kit should be purchased to simplify the  
installation process. One of the junction boxes supplied  
with the LTC 8557 Series Kit can then be used to  
connect the RS-232 wires TX and GND from the  
.
c
drivers should have the terminating resistor removed  
when the looping cable is connected.  
Controller’s output to the user-supplied  
RS-232  
communication link. The RS-232 protocol requires  
simplex link operating at 9600 baud.  
a
Connect shielded twisted pair cable (Belden 8760 or  
equivalent) between the camera site receiver/driver  
Three installation sections are detailed below; select  
the type of application you will be using.  
location and the biphase output connections located on  
the interface unit.  
This document also includes various diagrams of  
typical applications, that will be helpful to refer to  
during installation.  
Bosch Security Systems | 08 May 2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | Installation  
EN  
8
polarity sensitive. Plug the power supply into a suitable  
AC power source.  
Connect the supplied 3 m (10 ft) data cable with two  
RJ-11 connectors, between the Controller unit and the  
junction box. The orientation is not important -- either  
end may be connected to either device.  
Connect an appropriate length of cable (not supplied),  
suitable for use with RS-232 signals, between the  
LTC 8557 Series junction box, and the camera site  
receiver/driver location. If the distance between the  
box and camera site is much over 20-30 m (60-90 ft),  
the use of user-supplied short haul modems or other  
RS-232 line extender devices may be required. These  
devices must be able to support an RS-232 simplex  
transmission rate of 9600 baud.  
Pin  
Pin  
1
6
Figure 1 Interface Unit Supplied with LTC 5136  
The removable terminal blocks have three  
connections: (+), (–), and (S [Shield]), as shown in the  
diagram above.  
The LTC 8557 Series junction box provides a  
removable screw terminal block for the data  
connections. The terminal block has four connections,  
marked 1, 2, 3, & 4, as shown in the junction box  
diagram.  
Select and maintain a wire color convention to avoid  
confusion at the camera site(s).  
EXAMPLE: White to (+), Black to (–), and Shield to (  
S).  
NOTE: The shield terminals (S) of the interface unit  
are connected to the shield wire of the cable. Skip to  
AutoDome Camera or Receiver/Driver Site Configuration to  
complete the installation.  
4.3 Installation Using RS-232 Data  
Direct to Camera Site (See Figure  
5)  
In this application, the RS-232 data that is generated  
by the Controller is connected directly to 232  
R
S-  
Series AutoDome cameras or RS-232 Allegiant  
Receiver/Driver units. The supplied interface unit is  
not used in this application. The AutoDome camera or  
receiver/driver must be set (via internal DIP switch or  
on-screen menu) for 9600 baud operation.  
Figure 2 Junction Box Supplied with  
LTC 8557 Series Kit  
Pins 1 and 2 are not used. Pin 3 is the  
Controller’s RS-  
232 TX output, and Pin 4 is the Signal Ground  
connection. Connect the wire from terminal 3 to the  
RX connection of the AutoDome camera or receiver/  
driver. Respectively, connect the wire from terminal 4  
to the data ground connection.  
Install one of the junction boxes supplied in the  
LTC 8557 Series Kit (ordered separately) in a location  
close enough to the Controller unit so that the supplied  
3 m (10 ft) data cable can be used. If desired, four holes  
are provided for mounting the LTC 8557 Series  
Only a single camera site can be connected in this  
junction box to a flat surface. The power supply (to  
power the Controller) should also be located near the  
LTC 8557 Series junction box. Connect the bayonet  
style connector of the power supply cable into the jac  
located on the side of the junction box. If the power  
manner – RS-232 signals cannot be wired using a daisy  
chain connection. Be sure to use cable suitable for  
RS-232 signals.  
k
Skip to AutoDome Camera or Receiver/Driver Site Configuration  
to complete the installation.  
supply cable must be attached to the power supply, the  
polarity is not important; the Interface Unit is not  
Bosch Security Systems | 08 May 2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | Installation  
EN  
9
signals. Connect the wire from terminal 3 to the RX  
connection of the RS-232 transmission device.  
Respectively, connect the wire from terminal 4 to the  
data ground connection.  
4.4 Installation Using an RS-232 Data  
Transmission Link to a Biphase  
Camera Site (See Figure 6)  
In this application, the RS-232 data that is generated  
At the camera side of the RS-232 transmission device,  
install the interface unit in a convenient location where  
it can easily be connected to the transmission device.  
by the Controller is connected directly to an  
RS-232  
transmission link (fiber optics, microwave, dial-up  
phone modems, etc.). The RS-232 transmission link  
must be able to support an RS-232 simplex  
transmission rate of 9600 baud. At the other end of the  
RS-232 transmission link, the RS-232 signal is  
converted into Allegiant biphase protocol, using the  
supplied interface unit. The biphase data is then  
connected to the AutoDome cameras or Allegiant  
receiver/driver units.  
NOTE: The interface unit is rated for indoor use only  
.
If desired, use the four holes provided to mount the  
box to a flat surface.  
Connect the bayonet style connector of the power  
supply cable into the jack located on the side of the  
interface unit. If the power supply cable must be  
attached to the power supply, the polarity is not  
important; the Interface Unit is not polarity sensitive.  
Plug the power supply into a suitable AC power  
source.  
Install one of the junction boxes supplied in the  
LTC 8557 Series Kit (ordered separately) in a location  
close enough to the Controller unit so that the supplied  
3 m (10 ft) data cable can be used. If desired, four holes  
Connect  
a
transmit wire and a signal ground wire from  
are provided for mounting the LTC 8557 Series  
the RS-232 transmission device to the desired input on  
the interface unit. Either the RJ-11 or the 9-pin D type  
connector input may be used. Refer to the Data  
Converter Pinouts section for the appropriate pin  
connections.  
junction box to a flat surface. The power supply (to  
power the Controller) should also be located near the  
LTC 8557 Series junction box. Connect the bayonet  
style connector of the power supply cable into the jac  
located on the side of the junction box. If the power  
k
supply cable must be attached to the power supply, the  
polarity is not important; the Interface Unit is not  
polarity sensitive. Plug the power supply into a suitable  
AC power source.  
Next, connect the biphase control code outputs of the  
interface unit to the data cable. Typically,  
a
single  
camera site receiver/driver is connected to a single  
output, but each biphase output of the interface unit is  
rated to handle up to eight (8) receiver/drivers when  
Connect the supplied 3 m (10 ft) data cable with two  
RJ-11 connectors, between the Controller unit and the  
junction box. The orientation is not important -- either  
end may be connected to either device.  
connected in a daisy  
chain configuration, to a maximum  
of 1.5 km (5000 ft). For a daisy  
chain connection, the  
cable is looped through each AutoDome camera or  
receiver/driver along the way. The last (and only the  
last) unit in the daisy chain connection should be  
terminated. All other receiver/drivers should have the  
terminating resistor removed when the looping cable is  
connected.  
Connect an appropriate length of cable (not supplied  
suitable for use with RS-232 signals, between the LT  
)
C
8557 Series junction box and the RS-232 transmission  
device. If the distance between the box and device is  
much over 20-30 m (60-90 ft), the use of user-supplied  
short haul modems or other RS-232 line extender  
devices may be required. These devices must be able to  
support an RS-232 simplex transmission rate of 9600  
baud.  
Connect shielded twisted pair cable (Belden 8760 or  
equivalent) between the camera site receiver/driver  
and the biphase output connections located on the  
interface unit. The removable terminal blocks have  
three connections: (+), (–), and (S [Shield]).  
FIGURE 1, Interface Unit Supplied with LTC 5136  
See  
The LTC 8557 Series junction box provides a  
removable screw terminal block for the data  
connections. The terminal block has four connections  
marked 1, 2, 3, & 4. See Figure 2, Junction Box  
Supplied with LTC 8557 Series Kit.  
.
Select and maintain a wire color convention to avoid  
confusion at the camera site(s  
).  
Example: White to (+), Black to (–), and Shield to (S).  
Pins 1 and 2 are not used. Pin 3 is the  
RS-232 TX output, and Pin 4 is the Signal Ground  
connection. Be sure to use cable suitable for  
Controller’s  
NOTE: The shield terminals of the interface unit are  
connected to the Shield wire of the cable.  
RS-232  
Bosch Security Systems | 08 May 2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | Setting Fast Address  
EN 10  
ON-998-ENTER causes all cameras,  
regardless of Fast address status, to enter the  
addressing mode.  
4.5 AutoDome Camera or  
Receiver/Driver Site Configuration  
Follow the standard installation instructions provided  
with the AutoDome Camera or Allegiant Series  
Receiver/Driver unit to connect the data cable to the  
unit. Set the address of the AutoDome camera or  
receiver/driver, to the camera number that will be  
selected on the Controller keypad. AutoDome cameras  
also support address setting via the on-screen menu  
Fast Address feature. The next section outlines setting of  
the AutoDome’s Fast Address.  
Video signals from the camera site are NOT connected  
to the Controller. The video signal(s) from the camera  
site(s) should be connected to an appropriate viewing  
monitor or other video processing equipment (switcher,  
multiplexer, etc.).  
Figure FA1  
3. Press ON-26-ENTER. The screen shown in  
FIGURE FA2 will be displayed. At this point,  
any camera whose ID does not begin with 26  
will exit the Fast Addressing mode.  
5
SETTING FAST ADDRESS  
FEATURE  
Use the AutoDome’s Fast Address feature to set the  
AutoDome address via the controller and on-screen  
menus instead of using the switch address  
(thumbwheel). Fast Address can also be used to change  
addresses, even if the thumbwheel switch is set.  
The following is an example of how to Fast Address an  
AutoDome (ID number 26636, logical camera #3).  
The AutoDome being Fast Addressed has the switc  
h
address (thumbwheel) set to 0.  
1. Call up the camera to the screen you are  
viewing (i.e. CAM  
ERA-3-ENTER).  
Figure FA2  
2. Press ON-999-ENTER. The screen shown in  
FIGURE FA1 is displayed.  
4. Press ON-636-ENTER. The screen shown in  
FIGURE FA3 is displayed. At this point,  
Camera ID 26636 will be the only camera in  
the Fast Addressing mode.  
Any camera without a Fast Address will  
display the screen in FIGURE FA1 when  
the ON-999-ENTER is used. Make sure you  
are viewing the camera that you want to  
program.  
If the camera’s Fast Address is the same as the  
keyboard address, ON-999-ENTER will  
make the camera enter the Fast  
mode. This is required to change or disable  
Fast  
Address  
a
Address.  
Figure FA3  
Bosch Security Systems | 08 Ma 2013  
y
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | Controller Operation  
EN 11  
5. Press ON-1-ENTER and the address is set.  
Once the Fast Address is set, the switch address  
(thumbwheel) is ignored. The Fast Address is  
stored to non-volatile memory, and will not  
change if power is removed or factory defaults  
to ensure that all Controller LEDs and buttons are in  
working order. It also automatically calibrates the  
center position of the analog joystick. Upon entering  
this mode, the Controller sounds a short beep. The  
display readouts and LEDs behind the first two rows of  
buttons also illuminate for about two seconds. During  
this time, the joystick undergoes calibration, so be  
careful not to move it until the LED displays have  
gone dark. The operator should note any LED display  
failures during the time they are illuminated.  
are restored (SET-899-ENTE  
R).  
To reset the dome’s address to the switc  
h
address (thumbwheel), repeat the above  
steps and end by pressing OFF-1-ENTE  
R
.
To check/confirm the address, call up the  
camera and press ON-997-ENTER. This  
command causes all cameras to briefly  
display their addresses.  
Each key may now be pressed to display  
a
unique  
code number associated with that key. Use the table  
below to ensure that all keys are operating properly  
Push the USER key last, as this will cause the  
Controller to exit the test mode.  
.
6
CONTROLLER OPERATION  
Operation is quite simple. If the camera number to be  
controlled is not visible in the LED displays, use the  
numeric keypad to select the desired camera, then  
press ENTER. The camera can now be operated using  
the appropriate joystick and/or lens controls. If  
appropriate, pre-position scenes and auxiliary functions  
can also be entered.  
Key  
Number  
0009  
0025  
0010  
0018  
0026  
0011  
0019  
0027  
0012  
0020  
0028  
0013  
0021  
Key  
Number  
0029  
0014  
0030  
0038  
0043  
0044  
0045  
0046  
1x53  
0x51  
Set  
9
Camera  
0
Shot  
On  
Off  
1
Enter  
Note that a delay of more than 3-4 seconds while  
Clear  
entering  
a
selection results in the Controller returning  
Focus (up)  
Focus (down)  
Iris (up)  
Iris (down)  
Up  
to the default camera entry mode. If this condition  
occurs, start the selection again, from the beginning.  
2
A complete description of the controls and indicators is  
provided in the next section.  
3
4
6.1 Controls/Indicators  
LED Indicators: The four digit, 7-segment LED display  
5
Down  
6
Left  
1x52  
0x54  
1x41  
is used to display data entry and the selected camera  
7
Right  
number  
.
8
Zoom (CW)  
Zoom (CCW)  
SET key: This key is used to set pre-position scenes of  
all AutoDome cameras and Allegiant Series Receiver/  
Drivers which are equipped with this option. Operate  
the joystick and lens controls to position the camera to  
the desired scene to be programmed. Press SET, then  
enter the desired pre-position number on the numeric  
keypad (1 to 99). Press ENTER to store the position.  
0x42  
NOTE: The  
x
digit shown in the number column, for  
up, down, left, right, and zoom values, indicates a speed  
value, and will change based on how far the control is  
activated.  
Certain pre-position numbers are also used to program  
certain AutoDome features. Refer to the  
AutoDome  
operation manual for a complete listing of the available  
features.  
USER key: Press USER-1-ENTER to enter the  
Controller diagnostic mode. This function can be used  
Bosch Security Systems | 08 Ma 2013  
y
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual | Controller Operation  
EN 12  
CAMERA key: This key is only used to correct an error  
when selecting a camera number. If another key is  
inadvertently pressed when a camera selection is being  
made, the Camera button may be pressed to put the  
Controller immediately back into camera selection  
mode. Normally, a camera selection is made by  
entering the desired camera number using the numeric  
NUMERIC keypad: These keys are used to enter  
numeric data. When the first numeric key is pressed,  
the LED display will become a data display and  
indicate the numeric value pressed.  
ENTER key: This key is used to terminate commands.  
When using the ON or OFF function, holding this key  
will cause the function to repeat until the key is  
released. This feature is useful where auxiliary  
functions are associated with level type camera  
adjustments.  
keypad, then pressing ENTE  
SHOT key: This key is used to recall pre-position  
scenes of all AutoDome cameras and Allegiant eries  
R.  
S
Receiver/Drivers that are equipped with this option.  
Press SHOT, then enter the desired pre-position  
number on the numeric keypad (1 to 99). Press  
ENTER to recall a previously stored camera position.  
CLEAR key: This key is used to clear invalid entries. In  
some cases, it can be pressed twice. If there is numeric  
data in the camera display, the first push clears this  
data, and the second push returns the Controller to the  
camera mode. This allows the operator to clear  
Certain pre-position numbers are also used to program  
certain AutoDome features. Refer to the  
AutoDome  
incorrect data without leaving the current mode. If  
there is no data in the LED display, the first push  
clears the entire Controller, back to the default state.  
operation manual for a complete listing of the available  
features.  
ON key: This key is used to activate auxiliary functions  
FOCUS and IRIS keys: These rocker switches are used  
of the AutoDome cameras and Allegiant  
Series  
to control the lens focus and iris functions.  
receiver/drivers. Press ON, then enter the desired  
auxiliary number on the numeric keypad, and press  
ENTER to complete the action.  
Joystick: Movement of the joystick left or right will  
pan the selected camera left or right. Movement of the  
joystick up or down will tilt the camera up or down.  
Rotation of the joystick knob will move the zoom lens  
in or out.  
Certain auxiliary numbers are also used to program  
certain AutoDome features. Refer to the  
AutoDome  
operation manual for a complete listing of the available  
features.  
If the camera is capable of variable speed operations,  
the degree of joystick deflection (or rotation) will  
correspond to different speed responses.  
OFF key: This key is used to deactivate auxiliary  
functions of the AutoDome cameras and Allegiant  
Series Receiver/Drivers. Press OFF, then enter the  
desired auxiliary number on the numeric keypad, and  
press ENTER to complete the action.  
Certain auxiliary numbers are also used to program  
certain AutoDome features. Refer to the  
AutoDome  
operation manual for a complete listing of the available  
features.  
Bosch Security Systems | 08 Ma 2013  
y
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual Technical Reference  
|
EN 13  
7
TECHNICAL REFERENCE  
Video Monitor  
Video Signal  
Power  
Supply  
Adapter  
Video  
Signal  
Data  
Converter  
Unit  
DVR or Video  
Switcher  
Up to 16 biphase  
control code outputs  
RS-232  
Data  
Power  
&
Typical AutoDome  
Cameras or Allegiant  
Receiver/Driver units  
Controller  
Figure 3 Typical Camera Site Using Biphase Control  
Code  
Video Signal  
Video Monitor  
Video Signal  
Power  
Supply  
Adapter  
Video Signal  
Daisy Chain  
Biphase Data  
Daisy Chain  
Biphase Data  
Data  
Converter  
Unit  
DVR or Video  
Switcher  
Typical biphase  
control code output  
RS-232  
Data  
Power  
&
Typical AutoDome Cameras or  
Allegiant Receiver/Driver units  
Controller  
Figure 4 TypicalMultiple Camera Sites Using Daisy Chain Biphase Control Code Wiring Configuration  
Bosch Security Systems | 08 Ma 2013  
y
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual  
|
Technical Reference  
EN 14  
Video Monitor  
Video Signal  
Power  
Supply  
Adapter  
RS-232 Cable or  
Communication Link  
LTC 8557  
Junction Box  
RS-232  
Data  
Power  
&
Typical AutoDome Camera or  
Allegiant Receiver/Driver unit  
Controller  
Figure 5 TypicalInstallation Using RS-232 Model Camera Site  
Video Signal  
Video Monitor  
Video Signal  
Data  
Converter  
Unit  
Biphase  
Data  
Power  
Supply  
Adapter  
Biphase  
Data  
DVR or Video  
Switcher  
Power  
Supply  
Adapter  
RS-232  
Data  
RS-232 Cable or  
Communication Link  
LTC 8557  
Junction Box  
Typical AutoDome  
Cameras or Allegiant  
Receiver/Driver units  
Controller  
RS-232 Data & Power  
Figure 6 TypicalInstallation Using RS-232 Communication Link to Biphase Camera Site  
Bosch Security Systems | 08 Ma 2013  
y
Download from Www.Somanuals.com. All Manuals Search And Download.  
|
LTC 5136 Series | Instruction Manual Technical Reference  
|
EN 15  
Pin  
Pin  
6
1
Pin  
Pin  
1
6
Figure 7 Supplied 6-Conductor 3 m (10 ft) Data Cable Detail  
Connector Pinouts:  
1. 12V  
2. Not used  
3. Rx (Not used)  
4. Tx  
5. Signal Ground  
6. 12V  
Pin  
6
Pin 1  
Figure 8 Rear Panel Controller Connector Detail  
154  
6.08  
127  
5.0  
122  
4.80  
108  
4.26  
38  
1.  
5
mm  
in  
132  
5.2  
70  
2.75  
mm  
in  
Figure 9 Mounting Dimensions of Supplied Interface Box  
Bosch Security Systems | 08 Ma 2013  
y
Download from Www.Somanuals.com. All Manuals Search And Download.  
LTC 5136 Series | Instruction Manual | Data Converter Pinouts  
8
DATA CONVERTER PINOUTS  
Data In - 9-Pin Connector (Male)  
Pin  
1
Connection  
No Connection  
2
Rx  
3
No Connection  
No Connection  
Ground  
4
5
6
No Connection  
No Connection  
No Connection  
No Connection  
7
8
9
KBD - RJ-11 Designations (If Used  
)
Pin  
1
Connection  
Output Voltage  
Signal Ground  
2
3
Rx  
4
Ground  
5
No Connection  
Output Voltage  
6
Bosch Security Systems | 08 Ma  
y
2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Computer Accessories ACU505A R2 User Manual
Blaupunkt Car Stereo System RD 148 User Manual
Blockhead Video Game Controller BHGC75 User Manual
BMW Automobile Z3 E36 7 User Manual
Bosch Appliances Clothes Dryer WTMC8320US CN User Manual
Brinkmann Gas Grill Gas Grill King User Manual
Bushnell Binoculars 280750 User Manual
Califone Speaker System DMS1 User Manual
Casablanca Fan Company Fan 59020 User Manual
Chromalox Electric Heater PF421 6 User Manual