Bosch Appliances Home Security System DS924IPET User Manual

DS924iPET (ITI # 60-511-02-95)  
Learn Mode (LM) Wireless PIR Motion Sensor  
Installation Instructions  
AVOID  
1.0 Overview  
Hot or cold air  
directed onto  
sensor  
Direct or  
reflected  
sunlight  
The DS924iPET is a Passive Infrared (PIR) Motion Sensor designed to  
detect movement in the interior of a structure by sensing the Infrared  
energy emitted from the human body as it moves across the Sensor’s field  
of view. When motion is detected the unit sends an alarm signal to the  
Control Panel. The DS924iPET is a high performance PIR Motion Sensor  
which uses advanced signal processing to provide outstanding catch  
performance and unsurpassed false alarm immunity. The DS924iPET is  
designed to ignore a dog up to 40 pounds, two cats and small rodents.  
Figure 1  
4.0 Mounting Procedure  
4.1 Surface or Corner Mounting  
2.0 Specifications  
General  
• Power is supplied by 3.6 VDC Lithium Battery. Saft LS14250  
(0.85AH, 1/2AAbattery).  
• Typical current draw is 12 micro-amps with LED disabled.  
• Typical battery life is 5 years.  
For Pet Applications, surface or corner mount the  
detector. Do not use the optional swivel bracket.  
IMPORTANT  
• Operating temperature range of +32°F to +120°F (0°C to +49°C).  
Don't  
point  
at  
Don't  
point  
where  
pets  
PIR Motion Sensor  
stairs  
6.5 Ft  
(2 M)  
• Coverage area 35 ft. by 35 ft.  
can  
climb  
• Internal coverage pointability +2° to -10° Vertical and ±10° Horizontal.  
• Field selectable sensitivity options of Standard, Intermediate, or High.  
• Three minute transmitter lockout time after alarm extends battery life.  
• Timed Walk Test Mode automatically disables LED after setup to extend  
battery life.  
NO  
NO  
Mount the detector 6 1/2 feet  
(2 meters) above the floor  
Figure 2  
• Remove the sensor’s cover by gently inserting a screwdriver into the  
• Cover activated Tamper indication. Optional wall activated Tamper is  
included.  
COVER  
notch at the bottom of the cover.  
• Completely loosen the mounting  
base locking screw.  
• Remove the mounting plate from  
the enclosure by prying it up  
and out from the bottom.  
• Punch out 2 appropriate holes  
in the mounting plate (for  
surface or corner applications).  
HINGES  
RF Transmitter  
10  
5
0
5
10  
• Integral RF transmitter capable of transmitting at least 500 feet open air.  
(Actual acceptable transmitter range should be verified for each  
installation).  
• Transmits low battery report (trouble) to the Control Panel.  
• Transmits supervisory signal to the Control Panel every 64 minutes.  
• Intended for use with listed compatible ITI Learn Mode control panels.  
LENS  
LENS  
FRAME  
WALK TEST LED  
0
4
8
S
I
SENSITIVITY PINS  
H
WALK TEST  
SWITCH  
TEST  
3.0 Installation Guidelines  
Do  
Note: The wall tamper cannot  
be used when corner  
mounting.  
VERTICALADJUST  
SCREW  
WALL TAMPER  
BYPASS  
JUMPER  
TAMPER  
SWITCH  
MOUNTING BASE  
LOCKING  
COVER  
LATCH  
SCREW  
• Keep all sensors within 100 feet of the Control Panel. The 100 foot  
distance recommendation is given as a starting guideline. The LM PIR  
Transmitter has an open air range of at least 500 feet, but the installation  
environment may influence this range.  
• Mount the sensor so there is a reference point (such as a wall) at the  
end of its detection pattern.  
• Mount the sensor so that an intruder will most likely walk across the  
detection pattern.  
• Mount the sensor 6.5 feet above the floor.  
FRONT VIEW OF ENCLOSURE WITH COVER OFF  
• If the wall tamper function is  
Figure 3  
required,  
remove  
the  
rectangular knockout. Locate the small spring in the hardware kit. Hold  
the PIR base so the battery is visible. Place the spring on the black plastic  
shaft of the wall tamper switch just below the battery.  
• Remove the wall tamper bypass jumper located next to the walk test  
switch.  
• Using the mounting plate as a template, mark the location of the required  
holes on the mounting surface.  
• For installation on drywall or plaster, drill a 1/8" pilot hole to determine if a  
wall anchor is required.  
• Mount on an insulated outside wall facing in.  
• Mount on a surface which is rigid and free from vibration.  
Don’t  
• Secure the mounting plate to the wall with the #6 x 1" wood screws  
provided.  
• Mount in direct sunlight.  
• Aim at air conditioners, heat vents, wood stoves, fireplaces, intermittent  
heat sources, etc.  
HINGE  
• Aim at solar heated walls or uninsulated metal walls.  
• Aim at normally moving objects (ceiling fans, pets over 40 pounds, etc.).  
• Mount the sensor where it can be exposed to moisture.  
• Mount in locations where the temperature may be outside the sensor’s  
operating limits of +32°F to +120°F (0°C to +49°C).  
• Mount in areas with large metallic surfaces (e.g. heating ducts) or electrical  
wiring which may inhibit the sensor’s RF signals from reaching the  
Control Panel.  
CORNER  
SURFACE  
SURFACE  
CORNER  
CORNER  
FLUSH  
MOUNT  
CORNER  
MOUNT  
KNOCKOUT  
FOR  
WALL TAMPER  
• Mount in areas where the coverage may be blocked by any temporary  
items such as boxes or freight.  
TAB  
MOUNTING  
Figure 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bosch Appliances Home Security System LTC 4600 User Manual
Bosch Appliances Washer WFMC8400UC User Manual
Briggs Stratton Portable Generator 8000 Watt Portable Generator User Manual
Broan Trash Compactor 15XEWT User Manual
Bushnell Hunting Equipment 205107 User Manual
Bushnell Telescope 78 6000 User Manual
Canon Camcorder XL1SA User Manual
Canon Scanner 3297B002 User Manual
Casio Printer KL 7200 User Manual
Chicago Electric Humidifier 93035 User Manual