Bosch Appliances Home Security System D1255 User Manual

D1255/D1255B  
Installation Instructions  
EN Keypads  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D1255/D1255B | Installation Instructions | 2.0 Digital Keypad  
For the D9412G, D7412G, D7212G, D9124, D9412,  
D9112, D7412, and D7212 Control Panels consult  
Security System User’s Guide (P/N: 71-06141-000) and the  
D9412G/D7412G Program Entry Guide (P/N: 47775).  
2.0 Digital Keypad  
The D1255/D1255B Keypad features a digital keypad  
for accessing the menus, entering user passcodes and  
executing system commands in the control panel. As  
you press keys, the D1255/D1255B emits a muted  
beep tone (refer to Section 2.3 Audible Tones) to indicate  
that the entry is accepted. The keypad lights when you  
press keys, and remains lit for 20 sec.  
2.3  
Audible Tones  
The D1255/D1255B Keypad has a built-in speaker that  
produces several distinct warning tones. The speaker  
volume is changed by adjusting the potentiometer  
(refer to Item 5 in Figure 2 on page 4). Turn the  
potentiometer clockwise to increase volume and  
counterclockwise to decrease volume. The speaker  
volume also changes as you adjust the brightness of the  
display. Refer to Command 49 “Dim Display” in the  
Security System User’s Guide (P/N: 71-06141-000) for  
more information. You cannot connect external  
annunciation devices to the D1255/D1255B. The tones  
in Table 2 are silenced by entering a programmed  
passcode with the appropriate authority.  
When entering a passcode, press keys within 15 sec of  
each other. If 15 sec elapse between keystrokes, the  
entire entry clears, and you must start over. The  
keypad also "times out" on other functions if you wait  
15 sec or more between key presses.  
2.1  
Keypad Function Keys  
The D1255/D1255B has five function keys. These keys  
control your system.  
Table 1: Function Keys  
Table 2: Audible Tones  
Key  
Description  
Tone  
Description  
COMMAND  
Use the [COMMAND] bar in combination  
with one or two numeric keys to perform a  
function.  
Use the [ENT/YES] key to complete the  
entry of your passcode at the keypad.  
The [ENT/YES] key also selects the menu  
item shown during a menu selection.  
When viewing a list, pressing the [PREV]  
key returns you to the previously shown  
item.  
Burglary  
Signal  
Entrance  
Warning  
When an area is in alarm, the D1255/D1255B  
emits a steady, high-pitched “bell” tone.  
The D1255/D1255B emits an intermittent beep  
tone during entry delay periods to remind the  
user to disarm the area. This is a programmable  
option.  
The D1255/D1255B emits an intermittent beep  
tone during exit delay and counts down the  
number of seconds left until arming takes place.  
This is a programmable option.  
ENT/YES  
PREV  
Exit  
Warning  
Fire Signal  
When an area is in fire alarm, the  
D1255/D1255B emits a pulsed, high-pitched  
“bell” tone.  
Pressing an invalid key, or sequence of keys,  
causes the D1255/D1255B to emit a flat buzz  
tone.  
The D1255/D1255B emits a muted beep tone  
as each key is pressed to indicate that the entry  
is accepted. To disable this feature refer to  
Section 3.3.1 Setting the DIP Switches on  
page 5.  
When a trouble event occurs, such as a service  
alert, the D1255/D1255B emits a two tone  
warble until you enter COMMAND 4.  
NEXT  
Press the [NEXT] key to pass over the  
present item in a menu or list.  
Use the [ESC/MENU] key to returns to  
the idle display.  
MENU/ESC  
Invalid Key  
Buzz  
2.2  
Display  
Keypad  
Encoding  
Tone  
The D1255/D1255B Keypad displays the latest status  
conditions of the security system using words, numbers,  
and symbols in its display. When a series of events  
occur that affects the system, the D1255/D1255B  
displays each event in order of its priority.  
Trouble  
Buzzer  
For a complete listing and description of the  
D1255/D1255B 16-character displays and command  
functions available, consult the following  
documentation:  
Watch  
Tone  
When you activate the Watch feature, an  
intermittent beep tone (the same as the  
Entrance Warning Signal) alerts the user  
anytime a watch point is faulted. This option is  
programmable by point.  
Bosch Security Systems | 8/04 | 74-06819-000-F  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
D1255/D1255B | Installation Instructions | 3.0 Installation  
Figure 2: D1255/D1255B Internal Features  
1
2
3
2
4
9
5
3
1
2
3
4
5
6
3
6
8
7
6
1 - 16-Character Display  
2 - Top Tab Slot  
3 - Mounting Hole  
4 - Keypad  
6 - Bottom Tab Slot  
7 - Dip Switch  
8 - Four-Wire Flying Lead Connector  
9 - Speaker  
5 - Speaker Volume Control (Potentiometer)  
3.0 Installation  
To wire the D1255/D1255B:  
3.1  
Mounting the D1255/D1255B  
1. Power down the control panel.  
2. Gently push in the two bottom tabs of the  
D1255/D1255B enclosure cover using a small flat-  
bladed screwdriver.  
3. Lift the D1255/D1255B cover away from the base  
as the tabs are pushed back.  
4. Set the address switches (refer to Section 3.3.1  
Setting the DIP Switches on page 5).  
5. Connect the flying leads of the wiring assembly  
(provided) to the wires from the control panel  
(Table 3).  
The D1255/D1255B Keypad can be mounted using the  
following optional packages:  
D54B Keypad Flush Mount Kit (Brass)  
D54C Keypad Flush Mount Kit (Stainless)  
D55 Keypad Desk Stand - Desktop  
D56 and D56R Keypad Conduit Box  
3.1.1  
Mounting Locations  
Do not mount the keypad in a location  
where it is exposed to direct sunlight.  
Direct sunlight can interfere with the  
D1255/D1255B display screen visibility  
and damage internal components.  
6. Turn the keypad over and plug in the wiring  
connector through the opening in the back of the  
enclosure base.  
7. Mount the keypad base in the desired location.  
8. Secure the keypad in place from inside the  
enclosure base by inserting screws in the mounting  
holes.  
9. Replace the cover by aligning and inserting the top  
two tabs of the enclosure cover into the top two tab  
slots of the enclosure base.  
10. Hold the top edges of the enclosure cover and base  
in position.  
11. Push the tabs inward.  
Do not mount the D1255/D1255B in wet  
or moist locations.  
3.2  
Wiring  
Data and power connections between the control panel  
and the D1255/D1255B require a four-wire flying lead.  
The D1255/D1255B includes a wiring assembly  
consisting of four color-coded flying leads and a female  
four-pin connector plug at one end.  
The maximum recommended wire run for each  
D1255/D1255B is 2000 ft (610 m) with either 22 AWG  
(0.8 mm) gauge or 18 AWG (1.2 mm) gauge wire.  
12. Press the enclosure and cover together until the  
cover snaps into place.  
4
Bosch Security Systems | 8/04 | 74-06819-000-F  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D1255/D1255B | Installation Instructions |  
Setting the DIP Switches  
13. Press each key on the keypad toward the top of the  
keypad to ensure proper alignment and operation  
of each key through the mating keypad faceplate  
openings.  
3.3.1  
Switches 1 through 3 assign the address for the specific  
keypad. Leave Switches 4 and 6 in the ON position.  
For supervised keypads, assign only one  
keypad to each address. Switch 5 toggles  
the encoding tone ON and OFF. With the  
encoding tone turned ON, the keypad  
sounds a beep every time a key is  
pressed.  
Table 3: Wiring Connections  
Four-Wire Flying Leads  
from control panel  
D1255/D1255B Flying  
Leads  
DATA BUS B (30)  
DATA BUS A (31)  
POWER + (32*)  
COMMON – (29*)  
To Data Out (Green)  
To Data In (Yellow)  
To 12 VDC (Red)  
To Common (Black)  
Table 4: Switch Settings  
* = only on the D9412G Control Panel  
Switch  
Address #  
1
2
3
4
5*  
6
1
2
3
4
5
6
7
8
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
3.3  
DIP Switch Settings and Associated  
Functions  
Select the address of each keypad and silence the  
keypad encoding tone by setting the six-position DIP  
Switch (refer to Item 7 in Figure 2) located under the  
D1255/D1255B Keypad cover.  
*Encoding Tone ON/OFF.  
4.0 Specifications  
Table 5: D1255/D1255B Specifications  
Power  
Nominal 12 VDC supplied by the control panel  
Current Required  
Idle:  
104 mA, armed or disarmed.  
Maximum:  
206 mA, with keypad lighted and warning tone ON.  
Wiring  
Four-wire expansion cable supplies Data In, Data Out, +12 VDC, and Common.  
Maximum resistance on the conductors connected to SDI BUS A and SDI BUS B is 25 .  
4.6 in. x 8.1 in. x 0.8 in.  
(11.6 cm x 20.7 cm x 20.7 cm)  
Dimensions  
H x W x D  
Color  
D1255  
PMS Warm Gray  
D1255B  
White and PMS 429 Gray  
Display  
Operating Temperature  
Relative Humidity  
16-character vacuum fluorescent display. Each character is a 14-segment unit. Soft blue color.  
+32°F to +122°F (0°C to +50°C)  
5% to 85% @ +86°F (+30°C)  
Bosch Security Systems | 8/04 | 74-06819-000-F  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
D1255/D1255B | Installation Instructions | 4.0 Specifications  
Table 6: Control panel compatibility chart  
Maximum Number of Keypads  
Control panel  
D9412G  
D7412G  
D7212G  
D9124  
D9412  
D9112  
D7412  
D7212  
Supervised  
Unsupervised  
8
8
8
8
8
8
8
8
32  
32  
32  
32  
32  
32  
32  
32  
6
Bosch Security Systems | 8/04 | 74-06819-000-F  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D1255/D1255B | Installation Instructions | Notes  
Bosch Security Systems | 8/04 | 74-06819-000-F  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bosch Security Systems  
130 Perinton Parkway  
Fairport, NY 14450-9199  
Customer Service: (800) 289-0096  
Technical Support: (888) 886-6189  
© 2004 Bosch Security Systems  
74-06819-000-F  
Download from Www.Somanuals.com. All Manuals Search And Download.  

BenQ Cell Phone M555C User Manual
Black Decker Automobile Accessories BB212 User Manual
Bosch Appliances DVR DVR 16K User Manual
Boss Audio Systems Musical Instrument ME 50B User Manual
Carrier Air Conditioner 324423 751 User Manual
Carrier Heat Pump 50TFQ008 012 User Manual
Casablanca Fan Company Outdoor Ceiling Fan 55027 User Manual
CDA Cooktop HCG501 User Manual
Chief Manufacturing Indoor Furnishings MSM User Manual
CH Tech Network Card VX405C User Manual