Bosch Appliances Home Security System CCS 800 Ultro User Manual

CCS 800 Ultro  
Installation and Operating Manual  
en Discussion System  
Manuel d’installation et d’utilisation  
fr  
Système de Discussion  
Installations- und Bedienungshandbuch  
zh-t  
zh-s  
th  
de Diskussionssystem  
Manual de instalación y funcionamiento  
es Sistema de Conferencias  
Installatie- en gebruikshandleiding  
nl  
it  
Discussiesysteem  
Installazione e Manuale operativo  
Sistema audio congressuale  
ja  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 5  
1 About this manual  
2 Introduction  
This "Instructions For Use" manual provides all the  
information required to install and operate the CCS 800  
Ultro Discussion System.  
The CCS 800 Ultro Discussion System is a discussion  
system for use in meeting and conference venues with a  
limited number of participants.  
Conventions  
A CCS 800 Ultro Discussion System consists of:  
One Control and Power Supply Unit (CPSU).  
Maximum 50 units of which one or more chairman  
unit(s).  
Warning  
Warnings draw attention to instructions that  
must be followed to prevent personal injury.  
Extension cables if required (5m or 10m).  
Peripheral audio and/or telecommunication  
equipment.  
The CPSU is the heart of the discussion system which  
controls the microphones of the chairman and delegate  
units as well as providing facilities for audio inputs and  
outputs. It also supplies the power for the CPSU itself,  
chairman unit(s) and delegate unit(s).  
Caution  
Cautions draw attention to instructions that  
must be followed to prevent damage to the  
equipment.  
With the use of Digital Acoustic Feedback Suppression  
the loudspeaker volume can be increased significantly  
before feedback appears. Digital Acoustic Feedback  
Suppression is only available in LBB 3310/10.  
Note  
Notes draw attention to special instruction tips  
or other useful information.  
A delegate unit enables participants to actively join in  
a discussion (i.e. speaking and listening) by means of a  
microphone, controlled by an on/off button and  
a built-in loudspeaker or external headphone.  
A chairman unit has the same function as a delegate  
unit with the addition of a 'Priority' button, that enables  
its operator to control the debate by temporary or  
permanently overruling and muting all active  
microphones, depending on an internal setting in the  
chairman unit.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 6  
3 Control and power supply  
unit (CPSU)  
4 Speaker volume control of all connected delegate  
and chairman units.  
5 Volume control of the speaker or headphone of the  
CPSU.  
6 Headphone connection with 3.5 mm stereo jackplug  
socket.  
CC  
S
8
0
0
UL  
T
R
O
7 Trunk output 1 and 2. For loopthrough connection of  
the delegate and chairman units. To each output a  
maximum of 25 units can be connected.  
The maximum length of cable between the outputs  
of the CPSU and the last unit in the system is  
100 m (328 ft).  
2
2
1
3
6
2
7
1
0
10  
6
2
7
1
0
10  
1
2
3
4
5
6
8 Microphone input with gain adjustment for external  
microphone. The external microphone will be  
muted when the priority button on the chairman unit  
is pressed.  
Trunk in/out  
Microphone  
Recorder  
Line  
Telephone Insertion  
In  
Digital Acoustic  
Feedback Suppression  
Out  
Gain  
Gain  
90-260 V~  
9 Recorder input with gain control and recorder  
output connection.  
10 Line input and output for connecting a PA-system or  
other audio equipment.  
7
8
9
11  
13  
14  
10 12  
11 Telephone coupler input and output for connecting a  
remote participant.  
Figure 3.1  
1 Mains On/Off switch.  
Note  
The telephone input signal to the CPSU is not  
added to the telephone output signal from the  
CPSU to prevent line echo due to feedback.  
2 Power On LED indicator (green).  
3 Microphone-mode switch.  
Open mode with auto switch-off. To select  
the maximum number of delegate microphones  
to be activated simultaneously (1, 2, 3 or 4).  
The microphone automatically switches off if  
the speaker does not speak for 30 seconds.  
The microphone can manually be switched off  
by pushing the button on the delegate unit.  
Open mode. To select the maximum number  
of delegate microphones to be activated  
simultaneously (1, 2, 3 or 4). The microphone  
must be switched on or off manually by pushing  
the button on the delegate unit.  
12 Insertion connection. To connect an external audio  
equalizer for speech quality improvement under  
difficult acoustic conditions (1 = without equalizer,  
0 = insertion connection is internally open,  
providing means to connect an external equalizer in  
the path from microphone signals to delegate/  
chairman loudspeakers).  
Note  
Position "1" required for internal loop-through  
of the microphone signals to the delegate/ chair-  
man unit loudspeakers.  
Override mode. Only one delegate  
microphone can be activated. If a new delegate  
presses his microphone button, the microphone  
unit of the current speaker will be switched off.  
Chairman only mode. Only the chairman  
units can be activated.  
13 Digital Acoustic Feedback Suppression (DAFS)  
switch to activate or deactivate the DAFS.  
Test mode. For proper installation check.  
All the light-rings and LED's of the connected  
units will lit, if properly connected.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 7  
14 Mains input connection. Use the included mains  
cord to connect the CPSU to the mains socket.  
In some countries it may be necessary to replace the  
supplied mains cable by a local one. Brown = live,  
blue = neutral and green/yellow = earth.  
9 Chairman Priority button. When pressed emits  
chime tone, overrules/mutes all active microphones  
of delegate units in the system and keeps the  
chairman's microphone on for as long as the button  
is pressed (setting can be changed in the chairman  
unit).  
(Replacement and colour indication not applicable  
to mains cords for North America).  
In systems with several chairman units these settings  
are independently selectable for each chairman unit.  
4 Delegate and Chairman unit  
5 Installation  
1
Warning  
The CPSU must be earthed via the mains sup-  
ply for safety reasons and to ensure the speci-  
fied audio performance of the system. Do not  
open the CPSU and/or delegate/chairman  
units, no user serviceable parts inside.  
A
B
4
8
3
7
2
5
6
9
8
5.1 Connecting the delegate and  
chairman units  
Figure 4.1  
The chairman unit (B) has the same function as a  
Delegate unit (A) with the exception of a 'priority'  
button.  
Trunk in/out  
Microphone  
Recorder  
Line  
Telephone Insertion  
In  
Digital Acoustic  
Feedback Suppression  
1
Out  
Gain  
Gain  
90-260 V~  
1 Microphone with red illuminated indicator ring,  
lights when the microphone is ON.  
4
3
2 Two 3.5 mm stereo headphone sockets, one at each  
side, for headphone or recorder connection.  
Insertion of a headphone jack in one or both sockets  
automatically mutes the unit's loudspeaker.  
3 Built-in loudspeaker, automatically muted when the  
microphone is on.  
3
1
1
2
2
2
2
4 Red (LED) indicator above the microphone push  
button, for microphone ON indication.  
3...25  
3...25  
Figure 5.1  
5 7-pole circular female socket for loopthrough  
connection to the next unit.  
Connect the delegate (2) and chairman (3) units to the  
trunk connectors of the CPSU (1). Use an extension  
cable (4) if necessary.  
6 2m flying lead connection cable with sturdy  
moulded 7-pole circular male connector for  
connection to the previous unit or CPSU.  
7 Rotary volume control for headphones only.  
8 Microphone ON/OFF push-button.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 8  
5.2 Connecting up to 150 units  
CCS 800 Ultro can be used with up to 150 units by  
adding maximum 2 additional control units acting as  
power supply units only. The system is controlled by the  
master LBB 3310. The cables necessary for these  
connections can be delivered by your local dealer.  
max. 6 x 25 units  
CC  
S
8
0
0
U
LT  
R
O
2
2
1
3
6
2
7
1
0
9
3
10  
6
2
1
8
0
9
10  
CC  
S
8
0
0
U
LT  
R
O
2
2
1
3
2
7
1
0
10  
6
2
7
1
0
9
10  
CC  
S
8
0
0
U
LT  
R
O
2
2
1
3
4
6
2
7
1
0
9
3
10  
6
2
7
1
8
0
10  
Figure 5.2  
5.3 Locking the extension cable  
5.4 Connecting an external  
microphone  
Trunk in/out  
Microphone  
Recorder  
Line  
Telephone Insertion  
In  
1
Digital Acoustic  
Feedback Suppression  
Out  
Gain  
Gain  
90-260 V~  
3
Figure 5.3  
2
Cable locking clamps can be used in combination with  
the extension cables to prevent accidental  
disconnection.  
Figure 5.4  
Put the external microphone (2) connector in the  
microphone input of the CPSU (1).  
Adjust the sensitivity by use of the gain control (3).  
Use only microphones with balanced output.  
The microphone input provides a 12V phantom power  
supply.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 9  
5.5 Connecting a wireless  
microphone  
Connect the cabling of the tape recorder (2) to the  
recorder input and output of the CPSU (1). Use the gain  
control (3) to adjust the sensitivity of the recorder input  
of the CPSU.  
Trunk in/out  
Microphone  
Recorder  
Line  
Telephone Insertion  
In  
Digital Acoustic  
Feedback Suppression  
Out  
Gain  
Gain  
90-260 V~  
5.7 Connecting a PA-system or  
other external equipment  
1
Recorder  
Telephone Insertion  
Line  
receiv  
e
r
Gain  
Gain  
Figure 5.5  
2
Connecting a wireless microphone to the external  
microphone input is possible with the included 50dB  
attenuator. This way of connection allows interruption  
of the wireless microphone by the chairman's priority  
button.  
3
Figure 5.7  
Connect a PA-system (3) or other devices (2) to the in-  
and output of the CPSU (1).  
5.6 Recording/play back the  
conversation  
Connect audio sources to the line input, a PA amplifier  
or other sound-processing devices to the line output.  
1
Line  
Telephone Insertion  
Recorder  
In  
Out  
Gain Gain  
3
RECORD  
PLAY  
In  
Out  
2
Figure 5.6  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 10  
5.8 Connecting a telephone coupler 5.9 Connecting an equalizer  
1
1
Recorder  
Line  
Telephone  
Insertion  
Recorder  
Gain  
Line  
Telephone Insertion  
In  
In  
Out  
Gain  
Gain  
Out  
Gain  
3
4
2
2
4
3
Figure 5.8  
Figure 5.9  
Connect the telephone coupler (2) to the telephone  
input and output of the CPSU (1). The telephone  
coupler is further connected to the telephone wall  
socket (4) and a telephone (3) for dialing.  
Put the insertion switch (3) in position "0" and connect  
the cabling (2) of the (mono) equalizer (4) to the  
insertion input and output of the CPSU (1). Switch (3)  
must be in position "1" (loop through) if the insertion  
input/output is not used.  
A connection to a telephone network must always be  
made via a telephone coupler that provides adequate  
isolation between the telephone network (PBX) and the 5.10 Mains connection  
CCS 800 Ultro system. The telephone coupler shall also  
meet all relevant requirements for this type of  
Trunk in/out  
Microphone  
Recorder  
Line  
Telephone Insertion  
In  
1
Digital Acoustic  
Feedback Suppression  
Out  
Gain  
Gain  
communication equipment as imposed by law and/or  
responsible telecommunication organisations in the  
country of use.  
2
90-260 V~  
CCS 800 ULTRO  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
5
Caution  
3
4
Never try to make a direct connection between  
the telephone network and the CCS 800 Ultro  
discussion system.  
Figure 5.10  
Use the supplied mains cord set (5) to connect the  
CPSU (1) to the mains supply (2). Press the on/off  
switch (3) to power up the system, the power on LED (4)  
will lit.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 11  
6 Operation  
6.1 Testing the connection of the  
delegate and chairman units  
4
1
3
2
2
1
3
4
CCS 800 ULTRO  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
Figure 6.1  
Put the mode selector in the test position, all light-ring  
indicators and LEDs of the delegate and chairman units  
must lit if properly connected.  
6.2 Using the microphone button of  
the delegate unit  
Figure 6.2  
Depending on the position of the microphone mode  
switch on the CPSU, pressing the microphone button on  
a delegate unit will activate the delegate microphone.  
Pressing again switches the microphone off.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 12  
6.3 Using the microphone button of  
the chairman unit  
1...4  
1...4  
Figure 6.3  
Pressing the microphone button on a chairman unit  
always activates the chairman microphone, independent 6.5 Priority mode settings in  
of the selected microphone mode.  
Chairman units don't switch off automatically.  
chairman unit  
0
I
6.4 Using the priority button  
I
0
1
1
1
2
A
B
B
Figure 6.5  
Remove the cable relief bracket (1) to set the chime and  
microphone switches in the required position at priority.  
0 = : no chime at priority  
1 = : (default) chime at priority  
0 = : delegate microphones permanently OFF at  
priority  
1 = : (default) microphones temporary OFF at  
priority  
2
A
Figure 6.4  
Pressing the priority button of the chairman unit "B"  
may be indicated by a chime tone and will deactivate all  
active delegate units "A" and activates the chairman  
microphone. Release of the button will either leave the  
delegate units deactivated or activates them again  
(depending on priority mode settings).  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 13  
6.6 Open mode  
Select the max. number ( 1, 2, 3 or 4) of delegate  
microphones which can be active at the same time.  
Note  
Chairmen can always switch on and off their  
microphones and are not included in the max.  
number.  
4
1
3
2
2
1
3
4
CCS 800 ULTRO  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
1...4  
1...4  
Figure 6.6  
themselves at the same time. If the speaker is silent for  
6.7 Open mode with auto switch-off approximately 30 sec. the active microphone switches  
off automatically.  
Select the max. number (1, 2, 3 or 4) of delegate  
microphones which can be activated by the delegates  
4
1
3
2
2
1
3
4
CCS 800 ULTRO  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
1...4  
1...4  
Figure 6.7  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 14  
6.8 Override mode  
4
1
3
2
2
1
3
4
CCS 800 ULTRO  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
A
A
B
A
B
Figure 6.8  
Each time a delegate presses the microphone button on  
a delegate unit, it will override the currently active  
delegate unit. So only one delegate microphone is active  
at the same time. Chairman microphones can always be  
switched on.  
6.9 Chairman only mode  
4
1
3
2
2
1
3
4
CCS 800 ULTRO  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
A
B
Figure 6.9  
Only the chairman units (B) can be activated. Delegates  
(A) can not switch on their microphone.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 15  
6.10 Volume control of the delegate  
and chairman units  
5
4
0
6
3
7
2
8
9
1
CCS 800 ULTRO  
10  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
5
5
4
0
6
4
0
6
3
1
3
1
7
9
7
9
2
8
2
8
10  
10  
2
1
2
1
Figure 6.10  
Turn the volume control (1) to set the volume of the  
loudspeakers of the delegate and chairman units (2).  
Adjust for maximum level without feedback. In the fully  
counterclockwise position all loudspeakers are muted.  
6.11 Using Digital Acoustic  
Feedback Suppression (DAFS)  
Trunk in/out  
Microphone  
Recorder  
Line  
Telephone Insertion  
In  
Digital Acoustic  
Feedback Suppression  
Out  
Gain  
Gain  
90-260 V~  
Note  
With the use of Digital Acoustic Feedback  
Suppression the loudspeaker volume can be  
increased significantly before acoustic feedback  
appears. The maximum achievable volume gain  
depends on the acoustical environment and  
positioning of the units. Artefacts may occur  
during microphone switching at very high  
volume levels. In general the achievable  
increased volume gain is 4 - 6 dB.  
1
Figure 6.11  
Put the Digital Acoustic Feedback Suppression switch  
(1) in position "0" and adjust the loudspeakers for  
maximum level without feedback. Switch Digital  
Acoustic Feedback Suppression on by changing the  
switch (1) to position "1". Then set the loudspeaker  
volume to the required level, but increasing the volume  
level more than 2 or 3 steps is not recommended.  
The Digital Acoustic Feedback Suppression is  
optimised for speech.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 16  
6.12 Monitoring volume control  
5
4
0
6
3
7
2
8
9
1
CCS 800 ULTRO  
10  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
CCS  
CCS  
800 ULTRO  
800 ULTRO  
2
2
2
2
1
1
3
3
6
6
2
2
7
7
1
1
0
0
9
9
10  
6
10  
2
2
7
7
1
1
0
0
9
9
10  
10  
Figure 6.12  
Use the built-in loudspeaker or a headphone to monitor  
the discussion. Adjust the volume using the monitoring  
volume control. The maximum level is controlled by  
the setting of the volume control for delegate and  
chairman units.  
6.13 Using a headphone  
CCS 800 ULTRO  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
1
2
Figure 6.13  
Use the rotary volume control (1) to adjust the volume  
of the headphones connected to the left and/or right  
side of the units. Inserting a headphone jack mutes the  
loudspeaker.  
The maximum level depends on the setting of the  
volume control (2) on the CPSU.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 17  
7 Troubleshooting  
Part of system not working  
Temporary no microphone reaction, and no sound or  
distorted sound from unit loudspeakers  
Possible cause  
Interrupted trunk-line cabling.  
Solution  
Possible cause  
Trunk-line overload.  
Solution  
Check the trunk-line cabling connections between  
the units and the CPSU, also use the test function on  
the CPSU.  
Reduce load on the trunklines by reducing the  
number of units, and/or the length of the trunk  
cables.  
No sound via delegate/chairman loudspeakers  
Possible cause  
Insertion switch in wrong position.  
Solution  
Acoustic Feedback  
Check if insertion switch at the rear of the CPSU is  
in position "1".  
Possible cause  
Loudspeaker volume too loud.  
Solution  
Possible cause  
Volume control position.  
Solution  
Check if the volume control for delegate/chairman  
loudspeakers on the CPSU is not in the fully counter  
clockwise position.  
-
Reduce gain using volume control for delegate/  
chairman unit loudspeakers on CPSU.  
If available, switch on Digital Acoustic Feedback  
Suppression.  
-
Possible cause  
Distance between units too small (microphone to  
loudspeaker of other units).  
Solution  
Possible cause  
Microphone active or headphone connected.  
-
-
Increase distance between units.  
If available, switch on Digital Acoustic Feedback  
Suppression.  
Note  
Units with active microphone or connected  
headphone(s) have their loudspeakers switched  
off.  
Possible cause  
Too close to microphone units, when using open  
headphones.  
Solution  
-
-
Increase the distance between headphone and  
microphone or disconnect headphones when not  
in use.  
If available, switch on Digital Acoustic Feedback  
Suppression.  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 18  
8 Technical data  
Monitor loudspeaker  
Output level at 0.5 m: 72 dB SPL/ 82 dB SPL  
(nominal/maximum)  
8.1 System Electrical and Electro-  
Acoustical Characteristics  
Frequency response: 320 Hz ... 10 kHz  
(-10 dB, ref. 1kHz)  
Impedance:  
25  
Volume control:  
50 dB attenuation range  
8.1.1 The CPSU  
Mains voltage:  
100 - 240 Vac, 10%, 50/60 Hz  
Current consumption: max. 0.9 A (100 Vac) - 0.3 A  
Monitor headphone  
Output level:  
-8 dBV/ +2 dBV  
(nominal/maximum)  
22 Ω  
(240 Vac)  
DC supply to  
contribution units:  
24V +/- 1V (current limited)  
Output impedance:  
Output connection:  
stereo jack socket (mono output)  
Line, telephone coupler and insertion in/outputs  
(unbalanced)  
Allowed impedance: any impedance  
Volume control:  
50 dB attenuation range  
Input sensitivity:  
-14 dBV/ +11dBV  
(nominal/maximum)  
33 kΩ  
-14 dBV/ +11dBV  
(nominal/maximum)  
500 Ω  
Loudspeaker volume control  
For delegate and  
Input impedance:  
Output level:  
chairman units:  
mute (50 dB att.) + 10 steps of  
1.9 dB  
Output impedance:  
Limiter threshold level  
To unit loudspeaker  
/headphone: 10 dB above nominal level  
Recorder in/output (unbalanced) - mono  
Input sensitivity:  
- 20 dBV/ + 5 dBV  
(nominal/maximum)  
Input sensitivity  
adjustment:  
Gain reduction due to NOM  
(Number of Open  
+0 / -20 dB  
Input impedance:  
Output level:  
47 k(for L and R channel)  
- 20 dBV/ + 5 dBV  
(nominal/maximum)  
500 Ω  
Microphones):  
NOM +/- 1 dB  
Auto microphone switch-off function selectable on  
the Control and Power Supply Unit  
Output impedance:  
After approximately 30 sec. not speaking (sound level  
below 64 dB SPL) the microphone is automatically  
switched off  
External microphone input (balanced)  
Input sensitivity:  
- 56 dBV  
(- 6 dBV via included adapter).  
Input sensitivity  
adjustment:  
System limits  
Number of delegate/chairman units connected to CPSU  
+6 dB / -6 dB  
Phantom supply:  
12V +/- 1V, 2 x 680 (+/-2%).  
(Phantom supply is not available  
when using the included  
adapter).  
Maximum in total:  
Maximum per  
trunk output:  
Maximum trunk length  
using CCS 800 Ultro  
standard cabling:  
50  
25  
100 m (328 ft)  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 19  
8.1.2 Combined Units  
Delegate microphones with transmission links to  
8.3 General Data  
delegate headphones and auxiliary outputs.  
8.3.1System Environmental Conditions  
Temperature range  
General  
Storage and transport: -20 to +70°C (-4 to +158°F)  
Frequency response: 125 Hz - 12.5 kHz tolerances  
acc. to IEC 914 standard  
Operational:  
+5 to +45°C (+41 to 113°F)  
Total harmonic distortion at overload  
at nominal input  
Ambient humidity  
level (85 dB SPL):  
at max. input  
< 0.5%  
Operational:  
Storage and transport: 0% - 99% RH  
20% - 95% RH  
level (110 dB SPL):  
< 3%  
Air pressure:  
Safety:  
600 mBar - 1100 mBar  
acc. to EN 60065 and acc. to  
UL6500  
8.2 Mechanical Data  
Resistance to shock,  
vibration, bump  
and transport:  
8.2.1Control and Power Supply Unit  
acc. to IEC68, 5G acceleration  
acc. to EN 55103-1 and FCC  
rules (part 15), class A  
Mounting:  
free standing on a table top or  
mounted in a 19" rack (requires  
3HU (Height Units) with bracket  
set LBB 3311/00). Information  
about how to make the necessary  
brackets for table flush mounting  
is included.  
EMC emission:  
EMC immunity:  
EMC approvals:  
acc. to EN 55103-2  
affixed with the CE mark EC  
directive 89/336 EEC  
acc. to IEC 801-2 and 801-4  
EN 61000-3-2 and EN61000-3-3  
UN-D 1400  
ESD:  
Mains harmonics:  
Transport:  
Dimensions(HxWxD): 84 x 361 x 143 mm (with 5.5  
mm feet)  
3.4 x 14.2 x 5.6 in (with 0.22 in  
feet).  
Weight:  
/00 version 1.5 kg (3.3 lb)  
/10 version 1.7 kg (3.7 lb)  
8.2.2Delegate/Chairman Units  
Dimensions (w x d x h)  
without mic.:  
124 x 172 x 63 mm  
(4.9 x 6.8 x 2.5 in)  
Length of mic. from  
mounting surface:  
/00 version, 313 mm (12.3 in)  
/50 version, 488 mm (19.2 in)  
0.9 kg (2.0 lb)  
Weight:  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 20  
8.3.2Equipment Range  
Control and power  
supply unit:  
LBB 3310/00  
LBB 3310/10 (with Digital  
Acoustic Feedback Suppression)  
19" rack mounting set: LBB 3311/00  
Bracket for flush  
mounting:  
can be made locally according to  
the illustration in 9 Appendix  
LBB 3330/00  
Delegate unit(s):  
LBB 3330/50  
(with long microphone)  
LBB 3331/00  
Chairman unit(s) :  
LBB 3331/50  
(with long microphone)  
Installation cable with  
connectors  
Extension cables :  
LBB 3316/00 (100 m)  
LBB 3316/05 (5m)  
LBB 3316/10 (10m)  
Cable locking clamps :LBB 4117/00 (set of 25 pieces)  
Transport suitcase for  
10 delegate/chairman  
units with standard  
microphone:  
LBB 3312/00  
LBB 3312/10  
Transport suitcase for  
one CPSU, 6 delegate/  
chairman units with  
standard and/or long  
microphone and some  
extension cables:  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 21  
9 Appendix  
9.1 Pin Configuration  
CCS 800 ULTRO  
5
5
4
1
4
0
6
4
0
6
3
2
3
1
7
9
3
1
7
9
2
1
3
4
2
8
2
8
10  
10  
Trunk in/out  
Microphone  
Recorder  
Gain  
Line  
Telephone Insertion  
In  
Digital Acoustic  
Feedback Suppression  
Out  
Gain  
90-260 V~  
7
5
6
4
2
3
1 3  
1
1
3
2
1
2
2
123  
A
B
C
D
E
A
Figure 9.1  
9.1.1 Trunk Connections (A)  
1 Audio contribution line  
2 GND  
3 Audio distribution line  
4 Control line 1  
9.1.2 External Microphone (XLR) (B)  
1 GND  
(0V, phantom supply)  
(+12V, phantom supply)  
(+12V, phantom supply)  
phantom supply acc. to  
DIN45596  
2 Signal +  
3 Signal -  
5 Control line 2  
6 V+ supply  
7 V- supply  
9.1.3 CINCH Connector (C)  
1 Signal +  
2 Screen  
9.1.4 Mains Connector (D)  
1 Mains  
2 Earth  
3 Mains  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 22  
9.1.5 Headphone Jack-plug (3.5mm) (E)  
9.2 Mounting Instructions  
1 Tip  
- Signal +  
2 Ring  
3 Sleeve  
- Signal -  
- Electrical earth/screen  
The CPSU can be attached in three different ways:  
In a 19" rack making use of the 19" rack mounting  
set LBB 3311/00. Place a blank 1HU panel above the  
CPSU to have sufficient space for cable connections.  
Mounted into a table using the flush mount bracket.  
On a table. Therefore drill four holes in the table and  
fasten the CPSU with four M3 screws (B).  
9.1.6 Mounting of connectors,  
LBB 3316/00  
Yellow  
Drain  
The delegate and chairman units can only be attached  
on a table. Therefore drill two holes in the table and  
fasten the unit with two M3 screws (A).  
Shield  
Shield  
C
CS  
8
00  
U
LTR  
O
Green  
2
5
4
2
5
4
1
Violet  
Blue  
3
1
3
7
6
7
6
Red  
Figure 9.3  
White  
Figure 9.2  
Ø3.5 (2x)  
34  
342.5  
A
B
Figure 9.4  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCS 800 Ultro | Installation and Operating Manual  
en | 23  
9.3 Bracket for Flush Mounting  
The drawing below gives the necessary information how  
to make a bracket for flush mounting the CPSU into a  
table.  
90˚  
ø8.6(4x)  
4.6 (2x)  
130  
50.3  
234.5  
135  
95.8  
175  
47.8  
64  
29.5  
6
2.5 (6X)  
4+0.5  
(4x)  
0
Figure 9.5  
Bosch Security Systems | 2003-06 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
© 2003 Bosch Security Systems B.V.  
Data subject to change without notice  
June 03 | 3922 988 54284  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Switch F5U407 User Manual
Black Decker Chainsaw LCS120 User Manual
Blomberg Washer WNF 5441 AE20 User Manual
Bolens Lawn Mower 111 112A User Manual
Bowers Wilkins Portable Speaker Bamp;W 602 S3 User Manual
BOXLIGHT Projector MP 39t User Manual
Canon Fax Machine 6356B002 User Manual
Carrier Air Conditioner 50SX User Manual
Casio Webcam EX TR350 User Manual
Chicago Electric Sander 66891 User Manual