Blodgett Oven B36 RAD User Manual

IMPORTANT FOR FUTURE REFERENCE  
Please complete this information and retain  
this manual for the life of the equipment:  
Model #: __________________________  
Serial #: __________________________  
Date Purchased: ___________________  
Installation & Operations Manual  
Infrared/Radiant Compact Broiler  
B36-NFR / B48-NFR  
B36-RAD / B48-RAD  
WARNING  
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.  
Read installation, operation, and maintenance instructions thoroughly before installing or servicing this equipment.  
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526 USA • www.Blodgettrange.com  
MANUAL 1186527 REV 3 (12/06)  
$30.00  
INFRARED/RADIANT COMPACT BROILER  
MANUAL SECTION SR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
INTRODUCTION  
INTRODUCTION  
Congratulations! You have purchased one of the finest pieces of heavy-duty commercial cooking equipment on the  
market.  
You will find that your new equipment, like all Blodgett Range equipment, has been designed and manufactured to  
meet the toughest standards in the industry. Each piece of Blodgett Range equipment is carefully engineered and  
designs are verified through laboratory tests and field installations. With proper care and field maintenance, you will  
experience years of reliable, trouble-free operation. For best results, read this manual carefully.  
RETAIN THIS MANUAL FOR FUTURE REFERENCE.  
This manual is for the Blodgett Range/Platinum Infrared and Radiant Compact Broiler, which may be mounted over a  
range or on a wall, or used as a countertop unit by attaching legs to the base. The serial plate is located under the  
broiler bottom grease drawer at the front, toward the left (see Figure 1 below).  
Read these instructions carefully before attempting installation. Installation and initial startup should be performed by  
a qualified installer. Unless the installation instructions for this product are followed by a qualified service technician (a  
person experienced in and knowledgeable of the installation of commercial gas and/or electric cooking equipment)  
then the terms and conditions on the Manufacturer’s Limited Warranty will be rendered void and no warranty of any  
kind shall apply.  
In the event you have questions concerning the installation, use, care, or service of the product, contact:  
Blodgett Range Technical Service  
1100 Old Honeycutt Road  
Fuquay-Varina, North Carolina 27526 USA  
919-552-9161  
Figure 1  
Location of Serial Plate  
Serial Plate (Hidden under grease drawer)  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
PAGE 3 OF 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING & MAINTENANCE  
INFRARED/RADIANT COMPACT BROILER  
SPECIFICATIONS  
NOTICE  
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,  
Inc. states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to  
installation requirements for equipment. Therefore, installations must comply with all local codes, or in the absence  
of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1,  
or the Propane Installation Code CAN/CGA-B149.2, as applicable, including:  
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during  
any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).  
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff  
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2  
psi (3.45 kPa).  
Blodgett Range reserves the right to change specifications and product design without notice. Such revisions do  
not entitle the buyer to corresponding changes, additions, or replacements for previously purchased equipment.  
This product is intended for commercial use only, not for household use.  
CLEARANCES  
There must be adequate clearance between the broiler and adjacent construction due to the heat generated by the  
broiler. Clearance must also be provided for servicing and for operation.  
The minimum clearance from non-combustible construction is 1” on the sides and 3.75" on rear (to permit combustion  
air to enter the rear of the broiler). To service the broiler components -all models require at least 6” accessibility-  
clearance on the right and left side.  
Adequate clearance must be provided in front of the broiler for operation and cleaning.  
The high-temperature flue products from the broiler burners flow out through a vented cover on top of the broiler.  
Installation under a vented hood is recommended.  
WARNING  
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION  
The countertop model requires a minimum clearance from combustible surfaces of 1" on the sides and 3.75” on  
rear.  
The wall-mount model requires a minimum clearance from combustible surfaces of 1" on the sides and 3.75" on  
the rear (which is provided by the wall-mounting bracket).  
The range-mount model, to follow range minimum clearance from combustible surfaces of 6" on the sides and  
rear.  
PAGE 4 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
CLEANING & MAINTENANCE  
DIMENSIONS  
Figure 2  
B36-NFR  
B36-RAD  
B48-NFR  
B48-RAD  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
PAGE 5 OF 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING & MAINTENANCE  
INFRARED/RADIANT COMPACT BROILER  
VENTILATION  
WARNING  
Improper ventilation can result in personal injury or death. Ventilation, which fails to properly remove flue products,  
can cause headaches, drowsiness, nausea, or could result in death.  
The flue vent, located at the top of the unit, must not be blocked or covered at any time.  
All gas appliances must be installed in such a manner that the flow of combustion and ventilation air is not  
obstructed. Provisions for adequate air supply must be provided.  
NOTICE  
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the  
warranty.  
Do not obstruct the front of the broiler since combustion air enters through this area. Be sure to inspect and clean  
the ventilation system according to the ventilation equipment manufacturer’s instructions.  
If a ventilation canopy is used, it is recommended that the canopy extend 6" past the broiler and that the bottom edge  
be located 6'6" from the floor. Filters should be installed at an angle of 45° or more from the horizontal. This position  
prevents dripping grease and facilitates collecting the run-off grease in a drip pan under the filter.  
A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may  
extinguish pilot flames. Fresh air openings approximately equal to the fan area will relieve such a vacuum. The  
exhaust fan should be installed at least 2" above the vent opening on the top of the broiler.  
If the broiler is connected directly to an outside flue, a CSA design-certified down draft diverter must be installed.  
In case of unsatisfactory performance by any gas appliance, check the appliance with the exhaust fan turned OFF. Do  
this only long enough to check whether doing so corrects any problems with equipment performance. Then turn the  
exhaust fan back on and let it run to remove any exhaust that may have accumulated during the test.  
GAS SUPPLY  
The broiler is design-certified for operation on natural or propane gases. The broiler is shipped configured and  
adjusted for the type of gas specified by the purchaser, which is indicated on the serial plate (see Figure 1 on page 3).  
Connect the broiler ONLY to the type of gas for which it is configured and adjusted.  
Infrared:  
Gas Type  
Natural Gas  
Propane  
Total BTU/hour  
40,000  
Burner Orifice  
Pilot Orifice  
Min. Supply Pressure  
7" W.C.  
Manifold Pressure  
4" W.C.  
No. 54 (P/N 1008754)  
No. 64 (P/N 1008764)  
0.055 (P/N 1008754)  
0.036 (P/N 1008764)  
40,000  
11" W.C.  
10" W.C.  
Radiant:  
Gas Type  
Natural Gas  
Propane  
Total BTU/hour  
40,000  
Burner Orifice  
Pilot Orifice  
Min. Supply Pressure  
7" W.C.  
Manifold Pressure  
4" W.C.  
No. 52 (P/N 1008952)  
No. 64 (P/N 1008764)  
0.055 (P/N 1008754)  
0.036 (P/N 1008764)  
40,000  
11" W.C.  
10" W.C.  
A model that mounts on the flue riser of a range will have a 3/8" rear gas connection (with a 3/8" male NPT connector)  
extending through the rear of the flue riser (see Figure 2 on page 5).  
Wall-mount and countertop models will have a 3/8” rear gas connection (with a 3/8” male NPT connector). The gas  
connection can extend directly out the rear of the broiler (near the bottom right-rear corner).  
Minimum supply pressure is 7" W.C. for natural gas, 11" W.C. for propane. An internal pressure regulator and shutoff  
valve are provided. If using a flexible-hose gas connection, the I.D. of the hose must not be smaller than the  
connector on the broiler, and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent  
undue strain on the gas connection. Test pressure should not exceed 14" W.C.  
PAGE 6 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
CLEANING & MAINTENANCE  
If applicable, the vent line from the gas appliance pressure regulator must be installed to the outdoors in accordance  
with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas  
Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.  
An adequate gas supply is imperative. Undersized or low-pressure lines will restrict the volume of gas required for  
satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems  
and affect burner-operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold  
pressure. The supply line to the broiler should be no smaller than the inside diameter of the pipe on the broiler to  
which it is connected.  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
PAGE 7 OF 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING & MAINTENANCE  
INFRARED/RADIANT COMPACT BROILER  
OPERATION  
DANGER  
EXPLOSION HAZARD  
In the event a gas odor is detected, shut down equipment at the main shutoff valve. Immediately call the  
emergency phone number of your gas supplier.  
CAUTION  
If the broiler pilots should go out the flow of gas to the broiler burners is NOT interrupted. Consequently, it is the  
responsibility of the operator to check the ignition of the burners immediately EVERY TIME the broiler is turned on.  
Should ignition fail after 10 seconds, turn off burners, wait 5 minutes, and then try again.  
NOTICE  
Blodgett Range infrared broilers cook food in about half the time of conventional broilers, so adjust cooking times.  
Blodgett Range infrared broilers are unique in design. They incorporate our exclusive ceramic tile burners, which  
generate infrared rays that provide better quality products in about one-half the usual broiling time, and with less gas  
input than ordinary broilers. Very little energy is wasted in heating secondary surfaces, which is necessary for  
conventional-type broilers.  
Since the surface of the ceramic tiles becomes red hot in less than one-half minute, the broiler is ready to start broiling  
with a very short preheat time, thereby saving time, labor and energy. These glowing surfaces emit intense infrared  
rays, which are transmitted directly onto the product, thereby yielding better tasting broiled food in less time.  
The broiler design supplies 100% clean primary air to the burners, ensuring efficient combustion and maintaining full  
production capacity and maximum recovery, even in the most severe conditions of grease vapors and smoke  
atmospheres, which are created during any broiling process.  
Blodgett Range infrared broilers provide such rapid speed and recovery that broiling techniques may require  
some modification in order to take full advantage of their productive capabilities.  
Blodgett Range Radiant broilers offer durable stainless steel Radiants with anti corrosive steel tube burners. Flame  
from the burners are distributed over Radiant plates providing a penetrating heat suitable for broiling or finishing  
delicate dishes  
The location of the broiler controls and other components are shown in Figure 3 on the following page.  
PAGE 8 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
CLEANING & MAINTENANCE  
Figure 3  
Broiler Operation  
Keep the bottom drip pan in place when broiling. Without it in place, excessive air is  
pulled past the burners, reducing temperature and cooking efficiency.  
LIGHTING AFTER GAS HAS BEEN SHUT OFF  
When turning on the main gas supply to an appliance or a group of appliances, do the following:  
1. Make sure that all the control valves and power switches of all the appliances are in the OFF position.  
2. Turn on the main gas supply valve.  
3. Light the standing pilots of each connected appliance.  
OPERATION OF INFRARED COMPACT BROILER  
Blodgett Range infrared broilers broil in half the time of ordinary broilers. The burners reach operating temperature in  
just 90 seconds, and their intense infrared energy quickly heats the food, not the surrounding air. The broiling rack  
adjusts to five heights, and rolls out for easy access.  
The cooking area has removable racks and drip trays for cleaning. As food cooks, drippings drain into a collection tray  
on the bottom of the broiler cavity. To operate the broiler, do the following:  
1. Light the constant-burning pilots located near the front of the broiler burners (unless the pilots are already lit).  
2. If necessary, pull out and empty the bottom grease drawer. (Always keep the drip trays in place while broiling.  
Without it in place, excessive air will be pulled past the burners, reducing the cooking temperature and efficiency.)  
3. Infrared: Turn the burner control to HIGH and visually check that the burners have ignited. When the burners  
ignite, a blue haze-type flame will cover the surface of the ceramics, but will gradually disappear within two  
minutes. When the burner control is set to HIGH, the ceramics will glow red and the flame on the surface of the  
ceramics should be barely visible, with little or no blue haze. When the burner control is set to LOW, the surface  
of the ceramics will glow very dull red and the flame will have a blue-haze color. (If the flame flutters or “pops” the  
broiler requires adjustment by a service technician.)  
Radiant: Turn the burner control to HIGH and visually check that the burners have ignited. Flames from the tube  
burner will spread over the stainless steel radiants. The stainless steel radiants will glow red within 3 minutes.  
4. If searing the food to mark it with grid marks is desired, before placing food on the grid move the broiler rack to its  
highest position and allow the burners to operate on HIGH for five minutes.  
5. Turn the burner control to HIGH or LOW (as appropriate for the food to be cooked).  
6. Raise or lower the broiler rack to the height appropriate for the food to be cooked. To raise or lower the rack,  
move the lever arm to the right, raise or lower it, then move it to the left into a notch.  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
PAGE 9 OF 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING & MAINTENANCE  
INFRARED/RADIANT COMPACT BROILER  
7. Pull out the rack, place food on the grid, and slide the rack back into the broiler. (It is recommended the rack be in  
the lowest position for loading food.)  
8. Cook the food for the appropriate time, turning it when appropriate. Periodically check the broiler grease drawer  
and empty it when necessary.  
9. When done broiling, turn the burner control to OFF. (To keep the broiler grid hot in order to mark food with sear  
marks without preheating, turn the burner controls to LOW and move the broiler rack to its highest position.)  
LIGHTING BROILER PILOTS  
The pilots should burn continuously unless the broiler is to be completely shut down. The broiler cavity has two or  
three pilots, each near the front of a pair of burners. If the pilots are extinguished, the pilot gas supply is NOT  
automatically interrupted. To light the pilots, do the following:  
1. Turn the control valves on the front of the broiler to OFF.  
2. Turn on the gas supply to the broiler (if not already on).  
3. Light the pilots.  
SHUTDOWN OF BROILER  
To place the broiler in a standby state (ready for use), turn the burner control valves to OFF. The pilots will remain lit.  
To completely shut down the broiler for an extended period (or prior to disconnecting the gas supply), turn OFF the  
manual shutoff valves of all gas supply connections. (This will extinguish all pilots.)  
PAGE 10 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
CLEANING & MAINTENANCE  
CLEANING & MAINTENANCE  
WARNING  
Shut off the gas supply to the appliance before cleaning or performing maintenance on any gas appliance.  
The appliance may be equipped with a restraint device to limit its movement in order to prevent damage to the  
gas connection. If disconnection of this restraint is necessary to move the appliance for cleaning or  
maintenance, reconnect the restraint when the appliance is moved back to its original installed position.  
Blodgett Range equipment is sturdily constructed of the best materials and is designed to provide durable service  
when treated with ordinary care. To provide the best performance, your equipment must be maintained in good  
condition and cleaned daily. Naturally, the periods for this care and cleaning depend on the amount and degree of  
usage.  
Following daily and periodic maintenance procedures will enhance long life for your equipment. Climatic conditions  
(such as salt air) may require more thorough and frequent cleaning or the life of the equipment could be adversely  
affected.  
Keep exposed, cleanable areas of broiler clean at all times. (See next page for instructions on cleaning stainless  
steel and baked-enamel surfaces.)  
DAILY CLEANING AND MAINTENANCE  
To prevent excess smoking, the broiler grid, bottom grease drawer, and the other broiler components must be kept  
clean of food remnants. Use a wire brush or similar scraping utensil. DO NOT use steel wool or a similar scrub pad  
that will leave small particles, which can get into food. The daily cleaning procedure is as follows:  
1. Move the broiling rack to the low position. Pull out the rolling broiler rack.  
2. Lift out the broiler grids and clean them with a wire brush or non-toxic solvent.  
3. Lift out the (2) drip shields and clean them with soap and water.  
4. With rolling rack pulled-out to its “stop,” clean all parts where residue can collect.  
5. Remove the bottom grease drawer and clean it.  
6. Clean all parts of the raising and lowering frame.  
7. Lubricate bearings with cooking oil (helps to extend the life of the bearings).  
8. Reassemble broiling rack mechanism.  
9. Check that nothing has been placed on top of the broiler (which will block the escape of combustion exhaust).  
10. Check that the air-intake openings on the rear of the broiler are not obstructed.  
MONTHLY CLEANING AND MAINTENANCE  
The following tasks should be performed monthly:  
1. Check for proper pilot operation. The flame on each pilot should be just large enough to extend along the flame  
carrier to the burner surface. If adjustment is necessary, call for service.  
2. Infrared: Check for proper burner operation. When the burner control is set to HIGH, the ceramics should glow  
red and the flame on the surface of the ceramics should be barely visible, with little or no blue haze. When the  
burner control is set to LOW, the surface of the ceramics should glow very dull red and the flame should have a  
blue-haze color. The flame should not flutter or “pop.” If adjustment is necessary, call for service.  
Radiant: Check for proper burner operation. When burner control is set to HIGH, blue flames should emit from  
the tube burner, and spread over the stainless steel radiant causing the radiant to glow.  
SEMIANNUAL CLEANING AND MAINTENANCE  
At least twice a year the venting system should be examined and cleaned.  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
PAGE 11 OF 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING & MAINTENANCE  
INFRARED/RADIANT COMPACT BROILER  
STAINLESS-STEEL SURFACES  
To remove normal dirt, grease and product residue from stainless steel surfaces that operate at LOW temperature,  
use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean  
cloth.  
To remove BAKED-ON grease and food splatter, or condensed vapors; apply cleanser to a damp cloth or sponge and  
rub cleanser on the metal in the direction of the polishing lines on the metal. Rubbing cleanser, as gently as possible,  
in the direction of the polished lines will not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR  
MOTION. Soil and burnt deposits, which do not respond to the above procedure, can usually be removed by rubbing  
the surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL  
WOOL as any particles left on the surface will rust and further spoil the appearance of the finish. NEVER USE A  
WIRE BRUSH, STEEL SCOURING PADS (EXCEPT STAINLESS), SCRAPER, FILE OR OTHER STEEL TOOLS.  
Surfaces, which are marred, collect dirt more rapidly and become more difficult to clean. Marring also increases the  
possibility of corrosive attack. Refinishing may then be required.  
“Heat tint” is darkened areas that sometimes appear on stainless steel surfaces where the area has been subjected to  
excessive heat. These darkened areas are caused by thickening of the protective surface of the stainless steel and  
are not harmful. Heat tint can normally be removed by the foregoing, but tint which does not respond to this procedure  
calls for a vigorous scouring in the direction of the polish lines using SCOTCH-BRITE scouring pads or a STAINLESS  
scouring pad in combination with a powered cleanser. Heat tint may be lessened by reducing heat to the equipment  
during slack periods.  
PAGE 12 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
INSTALLATION  
INSTALLATION  
NOTICE  
These installation procedures must be followed by qualified personnel or warranty will be void.  
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,  
Inc. states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to  
installation requirements for equipment. Therefore, installations must comply with all local codes, or in the absence  
of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1,  
or the Propane Installation Code CAN/CGA-B149.2, as applicable, including:  
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during  
any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).  
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve  
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45  
kPa).  
STEP 1: UNPACKING  
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE  
All containers should be examined for damage before and during unloading. The freight carrier has assumed  
responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a  
claim must be made with the delivering carrier.  
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be  
signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier  
can supply the necessary forms.  
A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not  
apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all  
contents plus all packing material.  
1. Cut the banding straps and remove the corrugated cardboard surrounding the broiler. Do not remove any of the  
attached tags or labels until the broiler is installed and working properly.  
2. Cut the banding strap holding the broiler to the wooden skid.  
3. If installing Infrared Compact Broiler which mounts over a range, go to Step 2a.  
If installing Infrared Compact Broiler which mounts on a wall, go to Step 2b.  
If installing Infrared Compact Broiler which has legs for countertop use, go to Step 2c.  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
PAGE 13 OF 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
INFRARED/RADIANT COMPACT BROILER  
STEP 2A: MOUNT ON FLUE RISER OF RANGE  
The Infrared/Radiant Compact Broiler mounts over a range. A special flue riser is shipped with the broiler and range.  
Depending on the shipping requirements, the broiler, flue-riser, and range base may already be partially or completely  
assembled.  
1. Attach the flue riser to the rear of the range using the installation procedure included in the range manual, but do  
not attach the wall shield (the back of the flue riser) yet.  
2. Lift the broiler (using two people is recommended) and hook the broiler-hook over the top-front edge of the flue  
riser. If necessary, move the broiler left or right so that the holes in the top of the broiler hook line-up with the  
holes in the top of the flue riser, then secure the broiler-hook to the flue riser using three #10 self tapping screws -  
provided.  
3. Secure the bottom of the broiler to the flue riser with the four ¼” self-tapping screws provided. The holes are  
accessible from the rear of the unit behind the wall shield.  
4. If the optional internal piping from the broiler to the range was ordered, connect the gas line now (as described in  
Step 3), before attaching the wall shield.  
5. Attach the wall shield, which forms the rear of the flue riser. The gas supply inlet extending out from the rear of  
the broiler should be accessible through the corresponding hole on the back of the flue riser.  
6. Go on to Step 3.  
Figure 4  
Mounting of Infrared/Radianr Compact Broiler on Flue-Riser  
PAGE 14 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
INSTALLATION  
STEP 2B: MOUNT ON WALL  
The Infrared/Radiant Compact Broiler is installed by first attaching a mounting bracket to the wall, then attaching the  
broiler to the bracket.  
1. Attach the wall-mount assembly to the wall using the six ¼” x 2” lag screws and six washers provided (see Figure  
5). Screw through frame and into wall studs since the broiler weighs about 175 pounds (77 kilograms).  
2. Check that the wall-mount is level (both side-to-side and front-to-back).  
Figure 5  
Installation of Wall Bracket for Infrared/Radiant Compact Broiler  
3. It may be more convenient to prepare the gas supply line before the broiler is mounted on the wall bracket. If so,  
install the supply line and connector now (but do not yet attach it to the broiler).  
4. Lift the broiler (using two people is recommended) and hook the broiler-hook over the top of the front of the wall  
bracket. If necessary, move the broiler left or right so that the holes in the top of the broiler hook line-up with the  
holes in the wall bracket, then secure the broiler-hook to the wall-mount bracket using three sheet-metal screws.  
5. Secure the bottom of the broiler to the wall-mount bracket with the four provided ¼” self tap screws. The holes are  
accessible from the opening in the bottom of the wall-mount unit.  
6. Go on to Step 3.  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
PAGE 15 OF 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
INFRARED/RADIANT COMPACT BROILER  
STEP 2C: ATTACH COUNTERTOP LEGS  
1. Install each leg by screwing them into the threaded holes in the bottom of the base.  
2. Stand the broiler on its legs and position to minimum clearances specified on serial tag.  
Figure 6  
Attaching Legs for Countertop Infrared/Radiant Compact Broiler  
STEP 3: CONNECT GAS SUPPLY  
If this equipment is being installed at over 2,000 feet altitude and that information was not specified when ordered,  
contact the appropriate authorized Blodgett Range Service Representative or the Blodgett Range Service  
Department. Failure to install with proper orifice sizing will result in poor performance and may void the warranty.  
The broiler is design-certified for operation on natural or propane gases. The broiler is shipped configured and  
adjusted for the type of gas specified by the purchaser, which is indicated on the serial plate (see Figure 1 on page 3).  
Connect the broiler ONLY to the type of gas for which it is configured and adjusted.  
The Infrared/Radiant Compact Broiler mounts on the flue riser of a range, and either will have a 3/8" rear gas  
connection (with a 3/8" male NPT connector) extending through the rear of the flue riser (see Figure 2 on page 5), or  
will have the optional internal-piping to the front-manifold of the range.  
For wall-mount and countertop models, the gas connection (3/8 NPT) extends directly out the rear of the broiler (near  
the bottom-right-rear corner), or (using an elbow) out the top of the broiler near the top-right-rear corner.  
Minimum supply pressure is 7" W.C. for natural gas, 11" W.C. for propane. An internal pressure regulator and shutoff  
valve are provided. If using a flexible-hose gas connection, the I.D. of the hose must not be smaller than the  
connector on the broiler, and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent  
undue strain on the gas connection.  
If applicable, the vent line from the gas appliance pressure regulator must be installed to the outdoors in accordance  
with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas  
Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.  
An adequate gas supply is imperative. Undersized or low-pressure lines will restrict the volume of gas required for  
satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems  
and affect burner-operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold  
pressure. The supply line to the broiler should be no smaller than the inside diameter of the pipe on the broiler to  
which it is connected.  
PAGE 16 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
INSTALLATION  
CAUTION  
ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE ONLY  
SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.  
ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE APPLIANCE HAS BEEN PUT INTO  
OPERATION. TEST PRESSURE SHOULD NOT EXCEED 14" W.C.  
1. Check that the control valves on the broiler are in the OFF position.  
2. Purge the gas supply line to clean out dust, dirt, or other foreign matter before connecting the line to the broiler.  
3. For wall-mount and countertop models, connect the gas supply to the inlet at right rear corner.  
CAUTION  
HOLD THE INLET SUPPLY PIPE WITH A WRENCH WHEN TIGHTENING ADDED FITTINGS TO AVOID  
DAMAGE TO THE REGULATOR, VALVE, AND OTHER COMPONENTS.  
4. For the flue-riser-mounted model, either attach the gas supply to the gas pipe extending out of a hole on the rear  
of the flue riser; or (if the optional internal piping was ordered) connect the gas pipe extending from the rear of the  
broiler to the corresponding gas pipe extending from the rear of the range below the broiler, then attach the wall-  
shield (the rear of the flue riser).  
5. Turn on the gas and check for leaks using soapy water.  
STEP 4: INSTALL SLOPED ENCLOSURE (OPTIONAL ACCESSORY)  
To install a sloped enclosure, remove the body-side screws and discard. Remove screws (3) on the bottom, toward  
the rear of the unit. Position the hanger clip and fasten with screws (3). Remove screws (3) in the bottom of the face  
plate. Slide the enclosure so that the bracket inserts into the hanger clip. Align the holes in the front of the enclosure  
with the holes in the bottom of the face plate. Fasten with screws (3).  
Figure 7  
Installation of Sloped Enclosure (If Ordered)  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
PAGE 17 OF 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
INFRARED/RADIANT COMPACT BROILER  
STEP 5: CHECK THE INSTALLATION  
1. Check that all screws and bolts are tightened.  
2. Check that gas connection has been made correctly.  
3. Move the broiler into the final position at which it will be operated.  
4. Check that the broiler is level.  
5. Check that the appropriate minimum clearances are satisfied (see page 4), including adequate clearance for  
combustion air to enter the rear of the broiler.  
6. Check that there is sufficient clearance to pull out the broiler rack and bottom drip pan.  
7. Check that adequate ventilation (fresh air supply and hood exhaust) is available to the room in which the  
appliance will operate.  
8. Wipe clean all surfaces.  
STEP 6: CHECK BROILER OPERATION  
1. Turn gas supply on. Immediately check all gas connections for leaks using soapy water.  
2. Light the pilots (see the appropriate Operation section elsewhere in this manual). Check that the pilot flames are  
large enough to extend along the flame carrier to the burner surface. If not, adjust the pilots (see page 20).  
3. Infrared: Turn on the broiler burners and check for correct flame appearance and height at both the HIGH and  
LOW settings. When the burners ignite, a blue haze-type flame will cover the surface of the ceramics, but will  
gradually disappear within two minutes. When the burner control is set to HIGH, the ceramics should glow red  
and the flame on the surface of the ceramics should be barely visible, with little or no blue haze. When the burner  
control is set to LOW, the surface of the ceramics should glow very dull red and the flame should have a blue-  
haze color. The flame should not flutter or “pop.” If necessary, adjust the burners (see page 21) and/or LOW  
setting (see page 20).  
Radiant: Turn the burner control to HIGH and visually check that the burners have ignited. Flames from the tube  
burner will spread over the stainless steel radiants. The stainless steel radiants will glow red within 3 minutes.  
4. Check that gas supply is adequate by simultaneously turning on all burners of all appliances connected to the  
same gas supply to their highest setting, then again checking that the broiler's pilot and burner flames have  
correct appearance and height.  
5. Turn off all burners and allow the broiler to cool.  
STEP 7: WIPE-CLEAN AND SHUT-DOWN APPLIANCE  
1. Wipe clean all surfaces.  
2. Unless the broiler is to be placed in service immediately, shut off the gas supply.  
3. Make sure that a copy of this manual is available to the people who will operate and maintain the broiler.  
PAGE 18 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
SERVICE  
WARNING  
ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS  
EXPERIENCED IN, AND KNOWLEDGEABLE OF, THE OPERATION OF COMMERCIAL COOKING  
EQUIPMENT. TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR  
RELIABLE SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY  
PARTS.  
NOTICE  
INSTALLATION OF OTHER THAN GENUINE BLODGETT RANGE RANGE PARTS WILL VOID THE  
WARRANTY ON THIS EQUIPMENT.  
The serial plate is located under the broiler bottom drip pan at the front, toward the left (see Figure 1 on page 3).  
Replacement parts (including parts not listed in this manual) may be ordered either through a Blodgett Range  
Authorized Parts Distributor or a Blodgett Range Authorized Service Agency.  
When ordering parts, please supply the Model Number, Serial Number, Part Number, and Part Description.  
TROUBLESHOOTING  
Problem  
Look for -  
Not enough heat  
– Low pressure in gas supply  
– Restriction in gas piping and/or valves  
– Misalignment of burner orifice tube  
– Clogged burner orifice  
– Incorrect burner orifice  
Too much heat  
– Incorrect orifices  
– Defective or incorrectly set pressure regulator  
Burner flame has excessive blue haze  
– Obstruction of combustion-air intake on rear of broiler  
– Exhaust gases blocked by objects sitting on top of broiler  
– Low pressure in gas supply  
– Misalignment of orifice tube  
Burner flame fluttering  
– LOW setting of burner valve out of adjustment  
– Cracked or loose ceramic  
Burner flame popping (Infrared)  
Slow burner ignition  
– Pilot flame out of adjustment  
– Pilot alignment out of adjustment  
Pilot outage  
– Pilot flame out of adjustment  
– Draft condition  
– Pilot orifice clogged  
– Incorrect pilot orifice  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAGE 19 OF 24  
INFRARED/RADIANT COMPACT BROILER  
ACCESS TO SERVICEABLE PARTS  
Some serviceable parts are only accessible by removing body side panels and the front panel.  
The main front panel is fastened with six sheet-metal screws. To remove the front panel, remove these screws, as  
well as the burner-control-valve knob and the rack-height-position-lever knob. The main front panel can then be pulled  
forward and removed. Each body side panel is fastened with two sheet-metal screws. Remove body-side screws and  
slide the body side forward and away from the unit.  
Figure 8  
Access to Serviceable Parts  
If necessary (or convenient), wall-mounted and flue-riser-mounted models can be un-mounted for servicing or repairs.  
Use two people since the broiler weighs about 175 pounds (77 kilograms). Refer to the installation procedure in the  
previous section of this manual for guidance.  
ADJUSTMENT OF BROILER PILOTS  
The pilots are adjusted at the factory. If later the pilots are over-adjusted to the point where the flame is leaving its  
port, or “blowing off,” the result is an unstable condition in which the pilot may extinguish. If necessary, adjust the  
pilots using the following procedure:  
1. If necessary, light the pilots.  
2. Locate the pilot adjustment screw (which adjusts both pilots). It is a small slotted screw located on the pilot valve,  
and is accessed though the slot in the front panel above the control-valve knob.  
3. Turn the pilot adjustment screw to adjust the size of the pilot flames. The flame on each pilot should be large  
enough to extend along the flame carrier to the burner surface.  
ADJUSTMENT OF LOW SETTING  
The minimum gas flow to the burners is controlled by the burner valves. It provides an infinite variable adjustment  
from low to high. Turn the knob to the desired position so that when the Cheese Melter control knob is in the LOW  
position, the burner flames do not flutter or “pop,” but rather burn with a dull red or a blue haze.  
PAGE 20 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
ADJUSTMENT OF BROILER BURNERS  
The burners require no air adjustment after they have left the factory. If a major change in burner operation is noticed,  
check for obstruction of airflow, around the orifice. Burner performance is affected by (a) orifice size, (b) pressure, (c)  
injection, and (d) primary airflow. The burner orifice must be centered within the air mixer opening.  
ADJUSTMENT OF GAS PRESSURE REGULATOR  
The pressure regulator is located in the right-hand and left-hand interior compartment of the broiler. Accessing it will  
require removing the front panel and the side panels of the broiler. The regulator is preset for 4" W.C. for natural gas,  
or 10" W.C. for propane gas. If adjustment is necessary, do the following:  
1. Turn broiler control knob to OFF.  
2. Attach a pressure-measuring device to the 1/8" NPT connector located on the front of each burner manifold.  
3. Turn the broiler control knob to HIGH and, with the burners lit, check the manifold pressure. The pressure should  
be 4" W.C. (for natural gas) or 10" W.C. (for propane gas).  
4. If necessary, adjust the pressure by unscrewing the top of the pressure regulator (use a screwdriver) to expose  
the adjustment screw underneath. Rotating the adjustment screw clockwise increases the manifold pressure.  
5. After the pressure has been adjusted, turn the broiler control knob to OFF, replace the top of the pressure  
regulator, and disconnect the pressure-measuring device (replacing the plug into the connector on the manifold).  
PARTS  
The following table describes the serviceable parts. For parts not listed, contact a Blodgett Range Authorized Parts  
Distributor or a Blodgett Range Authorized Service Agency.  
PARTS LIST  
Part Number  
1183202  
1183323  
1183273  
1183278  
1183304  
1183308  
1183269  
1183332  
1183201  
1183187  
1183209  
1183210  
1183222  
1183262  
1183263  
1183272  
1183284  
1183313  
1183257  
1183220  
1188958  
1183246  
1183277  
1183271  
1183281  
PARTS LIST  
Part Number  
1183318  
1183248  
1183264  
1183310  
1183315  
1183259  
1183295  
1183311  
1160484  
1184990  
1184192  
1060475  
1183279  
1183287  
1164085  
1185006  
1183256  
1183296  
1183297  
B36-NFR  
1
B36-RAD  
B36-NFR  
B36-RAD  
DESCRIPTION  
Body Side, Left  
DESCRIPTION  
W/A, Shaft-36”  
1
1
2
2
2
1
1
4
1
1
1
1
1
1
1
1
1
2
1
1
4
-
1
2
1
2
1
2
1
2
9
1
2
1
2
2
1
1
1
2
2
1
2
1
2
1
2
1
2
9
1
2
1
2
2
1
1
1
2
2
Body Side, Right  
Bracket, Bearing Lock  
Bracket, Spring Adjust  
Plate, Cover  
1
Tube, Burner Supply ( V )  
Tube, Pilot Adjust  
2
2
Tube, Flex, ¼ X 16” LG.  
Nipple, Pipe,BLK. 3/8” X 8”  
Tube, Burner Supply (H)  
Spring, Pivot Arm  
2
Bracket, Arm Adjust  
Clip, Retainer  
1
1
Bracket, Orifice  
4
Spring, Rack  
Front, Body, 36  
1
Roller Bearing  
Base, 36, SS  
1
Handle, Chrome  
Grease Drawer, BA  
Body, Bottom/Back, 36  
Stiffener, Cavity, SS, 36  
Cover, 36  
1
Knob, Cast Aluminum  
Knob, Ball  
1
1
Weight, Counter Balance  
Spacer, Bearing  
1
Plate, Heat Deflector, 36  
Rack, Mount Angle, 36  
Plate, Face, BA  
1
Valve ASM, Pilot  
1
Nameplate, Blodgett 8” X 1.3”  
Tube, Valve Supply, 36  
Rack, 36 (Chrome)  
Rack, 36 (CRS)  
1
Drip Pan, 36  
2
Mount, Burner, 36  
Deflector, Flue, 36  
Burner, Radiant  
1
1
-
(NAT) Gas Components  
Regulator, WC @ 4” NAT  
Valve, Burner, NAT  
ASM, Burner, Infrared  
W/A, Bracket Bearing  
W/A, Bearing Pivot  
W/A Bracket, Bearing  
4
1133301  
1176014  
1008754  
1008752  
2
2
4
-
2
2
-
2
2
2
2
2
Orifice Hood, Drill #54  
Orifice Hood, Drill #52  
2
4
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
PAGE 21 OF 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
PARTS LIST  
Part Number  
1183293  
1183306  
1183319  
1183320  
1183330  
1188961  
1183229  
1183275  
PARTS LIST  
Part Number  
1182628  
B36-NFR  
B36-RAD  
B36-NFR  
B36-RAD  
DESCRIPTION  
W/A, Arm Swing  
DESCRIPTION  
Pilot Assy SGS  
1
2
1
1
2
-
1
2
1
1
2
8
1
1
2
2
W/A, Arm, Connector  
W/A, Rack Adjust (Left)  
W/A, Rack Adjust (Right)  
ASM, Manifold Burner  
Radiant, SS  
(PROP) Gas Components  
Regulator, WC @ 10”, PROP  
Valve, Burner, PROP  
Hood, Orifice, Drill #64  
Pilot Assy SGS  
1165704  
1176015  
1008764  
1182628  
2
2
4
2
2
2
4
2
W/A, Rack Cradle-36  
W/A, Rack Carriage-36  
1
1
Infrared/Radiant Compact Broiler  
Manual  
1183237  
ASM, Inner Lining, SS, 36  
1
1
1186529  
1
1
PARTS LIST  
PARTS LIST  
B48-NFR  
1
1
2
2
2
1
1
4
1
1
2
1
1
1
1
1
1
2
1
1
-
B48-RAD  
1
B48--NFR  
B48-RAD  
Part Number DESCRIPTION  
Part Number  
1183127  
1183248  
1183264  
1183310  
1183315  
1183259  
1183295  
1183311  
1160484  
1184227  
1184192  
1060475  
1183279  
1183287  
1164085  
1185006  
1183158  
1183162  
1183165  
DESCRIPTION  
1183202  
1183323  
1183273  
1183278  
1183304  
1183308  
1183269  
1183332  
1183160  
1183173  
1183144  
1183141  
1183170  
1183161  
1183159  
1183155  
1183146  
1183150  
1183171  
1183169  
1188958  
1183246  
1183277  
1183271  
1183281  
1183293  
1183306  
1183319  
1183320  
1183331  
1188961  
1183117  
1183120  
Body Side, Left  
W/A, Shaft-48”  
1
2
1
2
1
2
1
2
9
1
2
1
2
2
1
1
1
2
2
1
2
1
2
1
2
1
2
9
1
2
1
2
2
1
1
1
2
2
Body Side, Right  
1
Tube, Burner Supply ( V )  
Tube, Pilot Adjust  
Tube, Flex, ¼ X 16” LG.  
Nipple, Pipe, BLK. 3/8” X 8”  
Tube, Burner Supply (H)  
Spring, Pivot Arm  
Bracket, Bearing Lock  
Bracket, Spring Adjust  
Plate, Cover  
2
2
2
Bracket, Arm Adjust  
Clip, Retainer  
1
1
Bracket, Orifice  
4
Spring, Rack  
Front, Body, 48  
1
Roller Bearing  
Base, 48, SS  
1
Handle, Chrome  
Grease Drawer, BA  
Body, Bottom/Back, 48  
Stiffener, Cavity, SS, 48  
Cover, 48  
2
Knob, Cast Aluminum  
Knob, Ball  
1
1
Weight, Counter Balance  
Spacer, Bearing  
1
Plate, Heat Deflector, 48  
Rack, Mount Angle, 48  
Plate, Face, BA  
1
Valve ASM, Pilot  
1
Nameplate, Blodgett 8” X 1.3”  
Tube, Valve Supply, 48  
Rack, 48 (Chrome)  
Rack, 48 (CRS)  
1
Drip Pan, 48  
2
Mount, Burner, 48  
Deflector, Flue, 48  
Burner, Radiant  
1
1
6
(NAT) Gas Components  
Regulator, WC @ 4” NAT  
Valve, Burner, NAT  
ASM, Burner Infrared  
W/A, Bracket Bearing  
W/A, Bearing Pivot  
W/A, Bracket, Bearing  
W/A, Arm Swing  
6
2
2
2
1
2
1
1
2
-
-
1133301  
1176014  
1008754  
1008752  
1182628  
1
2
4
-
1
2
-
2
2
Orifice Hood, Drill #54  
Orifice Hood, Drill #52  
Pilot Assy SGS  
2
6
2
1
2
W/A, Arm, Connector  
W/A, Rack Adjust (Left)  
W/A, Rack Adjust (Right)  
ASM, Manifold Burner  
Radiant, SS  
2
1
(PROP) Gas Components  
Regulator, WC @ 10”, PROP  
Valve, Burner, Prop  
1
1165704  
1176015  
1008764  
1182628  
1
2
4
2
1
2
4
2
2
12  
1
Hood, Orifice, Drill #64  
Pilot Assy SGS  
W/A, Rack Cradle-48  
W/A, Rack Carriage-48  
1
1
1
Infrared/Radiant Compact Broiler  
Manual  
1183168  
ASM, Inner Lining, SS, 48  
1
1
1186529  
1
1
PAGE 22 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFRARED/RADIANT COMPACT BROILER  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PAGE 23 OF 24  
INFRARED/RADIANT COMPACT BROILER  
INFRARED COMPACT BROILER  
Flue-Riser Mount, Wall Mount, or Countertop  
A product with the Blodgett Range name incorporates the best in durability and low maintenance. We all  
recognize, however, that replacement parts and occasional professional service may be necessary to extend the  
useful life of this appliance. When service is needed, contact a Blodgett Range Authorized Service Agency, or your  
dealer. To avoid confusion, always refer to the model number, serial number, and type of your appliance.  
Blodgett Range  
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526  
PAGE 24 OF 24  
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Speaker 157 User Manual
Bose Speaker System 10 Series II User Manual
Brother Printer HL 1040 User Manual
Bryan Boilers Boiler Broile System User Manual
Campbell Hausfeld Air Compressor CE500000AJ User Manual
Campbell Hausfeld Air Compressor FP2603 User Manual
Campbell Hausfeld Power Screwdriver CL157500AV User Manual
Campbell Hausfeld Staple Gun CHN10600 User Manual
Carrier Air Conditioner 30GT User Manual
Carson Stereo Amplifier SA 500 16 14V User Manual