Black Box Switch RS 232 422 485 User Manual

JULY 2002  
IC1020A  
IC1021A  
IC1022A  
Dual-Port USB Hub—RS-232/422/485  
Quad-Port USB Hub—RS-422/485  
Quad-Port USB Hub—RS-232/422/485  
CUSTOMER  
SUPPORT  
INFORMATION  
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)  
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746  
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
EMC Directive Statement  
Products bearing the CE Label fulfill the requirements of the EMC directive  
(89/ 336/ EEC) and of the low-voltage directive (73/ 23/ EEC) issued by the  
European Commission.  
To obey these directives, the following European standards must be met:  
• EN55022 Class B—Limits and methods of measurement of radio interference  
characteristics of information technology equipment.  
• EN55024—Information technology equipment immunity characteristics limits  
and methods of measurements.  
• EN60950 (IEC950)—Safety of information technology equipment, including  
electrical business equipment.  
Always use the cabling provided with this product if possible. If no cable is  
provided or if an alternate cable is required, use high-quality shielded cabling to  
maintain compliance with EMC directives.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOM STATEMENT  
NORMAS OFICIALES MEXICANAS (NOM)  
ELECTRICAL SAFETY STATEMENT  
INSTRUCCIONES DE SEGURIDAD  
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de  
que el aparato eléctrico sea operado.  
2. Las instrucciones de seguridad y operación deberán ser guardadas para  
referencia futura.  
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de  
operación deben ser respetadas.  
4. Todas las instrucciones de operación y uso deben ser seguidas.  
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca  
de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc..  
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que  
sean recomendados por el fabricante.  
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea  
recomendado por el fabricante.  
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá  
a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser  
referido a personal de servicio calificado.  
9. El aparato eléctrico debe ser situado de tal manera que su posición no  
interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá,  
alfombra o superficie similar puede bloquea la ventilación, no se debe colocar  
en libreros o gabinetes que impidan el flujo de aire por los orificios de  
ventilación.  
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor  
como radiadores, registros de calor, estufas u otros aparatos (incluyendo  
amplificadores) que producen calor.  
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del  
tipo descrito en el instructivo de operación, o como se indique en el aparato.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización  
del equipo no sea eliminada.  
13. Los cables de la fuente de poder deben ser guiados de tal manera que no  
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,  
poniendo particular atención a los contactos y receptáculos donde salen del  
aparato.  
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las  
recomendaciones del fabricante.  
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas  
de energia.  
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea  
usado por un largo periodo de tiempo.  
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean  
derramados sobre la cubierta u orificios de ventilación.  
18. Servicio por personal calificado deberá ser provisto cuando:  
A: El cable de poder o el contacto ha sido dañado; u  
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o  
C: El aparato ha sido expuesto a la lluvia; o  
D: El aparato parece no operar normalmente o muestra un cambio en su  
desempeño; o  
E: El aparato ha sido tirado o su cubierta ha sido dañada.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRADEMARKS  
TRADEMARKS USED IN THIS MANUAL  
AT, IBM, and PS/ 2 are registered trademarks of International Business Machines  
Corporation.  
Windows is a registered trademark of Microsoft Corporation.  
Any other trademarks mentioned in this manual are acknowledged to be the property of the  
trademark owners.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
Contents  
Chapter  
Page  
1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
2.2 Whats Included . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
2.3 Technical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
2.4 Connector Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
3.1 Operating System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
3.2 System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
4. Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
4.1 Original Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
4.2 Electrical Interface Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
4.2.1 Dual-Port USB Hub—RS-232/ 422/ 485 (IC1020A). . . . . . . . . . 12  
4.2.2 Quad-Port USB Hub—RS-422/ 485 (IC1021A) . . . . . . . . . . . . . 15  
4.2.3 Quad-Port USB Hub—RS-232/ 422/ 485 (IC1022A) . . . . . . . . . 17  
Appendix A. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
A.1 Troubleshooting Tips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
A.2 Calling Black Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
A.3 Shipping and Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
Appendix B. Electrical Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
B.1 RS-232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
B.2 RS-422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
B.3 RS-485 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
Appendix C. Asynchronous Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 1: Specifications  
1. Specifications  
Standards: USB version 1.1  
Speed: RS-232: Up to 460.8 kbps; RS-422/ 485: Up to 921.6 kbps  
Indicators: IC1020A: (5) Status LEDs: (3) USB Enabled; (2) Port Activity;  
IC1021A, IC1022A: (9) Status LEDs: (5) USB Enabled; (4) Port Activity  
Connectors: IC1020A: (1) USB Type B; (2) DB9 male;  
IC1021A, IC1022A: (1) USB Type B, (4) DB9 male  
Temperature Tolerance: Operating: 32 to 122°F (0 to 50°C); Storage: -4 to +158F  
(-20 to +70°C)  
Relative Humidity: 10 to 90% noncondensing  
Mean Time Between Failures (MTBF): Greater than 150,000 hours (calculated)  
Power: 500 mA per port supplied from the USB root hub or a self-powered hub  
Size: 1.5"H x 5.3"W x 7.1"H (3.8 x 13.5 x 18 cm)  
Weight: 1 lb. (0.5 kg)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
2. Introduction  
2.1 Overview  
The USB Hub equips the PC with 2 or 4 USB to RS-232/ 422/ 485 or RS-422/ 485  
asynchronous serial ports. It gives you a versatile interface for common serial  
needs. Three models are available:  
• The Dual-Port USB Hub (IC1020A) has 2 USB ports to RS-232/ 422/ 485 serial  
ports.  
• The Quad-Port USB Hub (IC1021A) has 4 USB ports to RS-422/ 485  
serial ports.  
• The Quad-Port USB Hub (IC1022A) has 4 USB ports to RS-232/ 422/ 485  
serial ports.  
Unlike more traditional products, the USB Hub does not require opening the  
computer case, nor does it require resources such as I/ O ports or IRQs.  
It does require a system that supports USB both in terms of hardware and  
operating system.  
2.2 Whats Included  
The USB Hub is shipped with the following items.  
(1) Dual-Port USB Hub RS-232/ 422/ 485, Quad-Port USB Hub RS-422/ 485, or  
Quad-Port USB Hub RS-232/ 422/ 485.  
(1) USB cable for connecting to the upstream host/ hub.  
(1) CD-ROM disk containing drivers and installation software.  
• This users’ manual.  
If anything is missing or damaged, contact Black Box at 724-746-5500.  
2.3 Technical Description  
The Dual-Port USB Hub (IC1020A) uses two chips. The Quad-Port USB Hubs  
(IC1021A and IC1022A) use four chips. These chips feature programmable baud  
rate, data format, 128-byte dual-port TX buffer, and 384-byte dual-port RX buffer.  
The RS-232/ 422/ 485 and the RS-422/ 485 transceivers support data rates up to  
921.6 kbps for RS-422/ 485 and 460.8 kbps for RS-232.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 2: Introduction  
2.4 Connector Pin Assignments  
The IC1020A has one USB Type B connector and two DB9 male connectors.  
The IC1021A and IC1022A have one USB Type B connector and four DB9 male  
connectors. The pinouts for the DB9 connectors are described in Tables 2-1  
and 2-2.  
Table 2-1. RS-422/ 485 DB9 male connector pin assignments.  
Signal  
Name  
Pin #  
Mode  
RX+  
RX-  
Receive Data Positive  
Receive Data Negative  
Transmit Data Negative  
Transmit Data Positive  
Ground  
1
Input  
2
Input  
TX-  
3
Output  
Output  
TX +  
GND  
RTS+  
RTS-  
CTS-  
CTS+  
4
5—  
6
Request To Send Positive  
Request To Send Negative  
Clear To Send Negative  
Clear To Send Positive  
Output  
Output  
Input  
7
8
9
Input  
Table 2-2. RS-232 DB9 male connector pin assignments.  
Signal  
Name  
Pin #  
Mode  
DCD  
RX  
Data Carrier Detect  
Receive Data  
1
Input  
2
Input  
TX  
Transmit Data  
Data Terminal Ready  
Ground  
3
Output  
Output  
DTR  
GND  
DSR  
RTS  
CTS  
RI  
4
5—  
6
Data Set Ready  
Request To Send  
Clear To Send  
Ring Indicator  
Input  
Output  
Input  
Input  
7
8
9
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
3. Installation  
3.1 Operating System Installation  
Choose Install Software at the beginning of the CD and follow the prompts to  
install SeaCOM.  
3.2 System Installation  
The screen capture shown in Figure 3-1 is taken from a Windows® 98 installation.  
Your particular operating system may differ slightly from what is shown, based on  
your version of Windows.  
The USB Hub can be connected to any upstream type A port either at the PC host  
or an upstream hub. The USB Hub is hot pluggable, meaning that you dont have  
to power down your computer before installation.  
Connect the USB Hub to an upstream host or hub.  
The New Hardware Found wizard will now locate the appropriate drivers. These  
drivers were installed during the software setup procedure. Once the drivers are  
found, a new window will pop up indicating the installation of each of the four  
new ports.  
If you view the Device Manager, you should have new COM ports in the Ports  
(COM & LPT) device class; this is shown in Figure 3-1.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 3: Installation  
Figure 3-1. System Properties screen, Device Manager tab.  
You can access your new COM ports by using the assigned COM identifiers as  
shown in Figure 3-1. In this case, it is COM3, 4, 5, and 6. However, this assignment  
will vary from system to system. At this point, the hardware is recognized and ready  
to use.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
4. Configuration  
4.1 Original Configuration  
This device ships with the following configuration:  
• 422 mode,  
• 120 ohm termination,  
• 1 K-ohm pull-up resistance on RX+, and  
• 1 K-ohm pull-down resistance on RX-.  
To change this configuration, you must open the box. Do this by removing the  
four screws located on the bottom. When reassembling, please note that the top  
and bottom are keyed to fit in only one direction.  
4.2 Electrical Interface Selection  
Each of the two DB9 ports on the IC1020A can be individually configured as an  
RS-232, RS-422 (2-wire operation), or RS-485 (2- or 4-wire operation) interface.  
Each of the four DB9 ports on the IC1021A is configured as RS-422 or RS-485.  
Each of the four DB9 ports on the IC1022A can be configured as RS-232, RS-422,  
or RS-485. This is selectable via the DIP switches and jumper shunts. The switch  
and jumper positions are described in Sections 4.2.1 through 4.2.3.  
4.2.1 DUAL-PORT USB HUB—RS-232/ 422/ 485 (IC1020A)  
You have a variety of configuration options for the two DB9 ports on the Dual-Port  
USB Hub. You can set both ports as RS-232, both ports as RS-422, both ports as  
RS-485, or any combination of these interfaces. You also need to select termination  
(ON or OFF) for each port, and pull-up and pull-down resistors (ON or OFF) for  
each port. When selecting a configuration for your Hub, refer to Tables 4-1  
through 4-3 and Figures 4-1 and 4-2.  
Jumpers E5, E6, E7, and E8  
To configure Port 1 on the Dual-Port USB Hub for RS-232, select Jumper E8 on  
the circuit board. To configure Port 2 for RS-232, select Jumper E5. (See Table  
4-1.) You do not need to set any DIP switches to configure Port 1 or 2 for RS-232.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: Configuration  
Table 4-1. Jumper settings.  
Jumper  
Port  
RS-232  
RS-422/ 485  
E52  
E6  
X
2
X
X
E7  
1
E8  
1
X
Switch SW4 Settings  
To configure the ports on the Dual-Port USB Hub for RS-422/ RS-485 instead of  
RS-232, select Jumper E7 for Port 1 and Jumper E6 for Port 2. (See Table 4-1.)  
When you are running RS-422 or RS-485, you also need to set switch SW4, positions  
1 through 10 (see Figure 4-1 and Table 4-2). For example, to set RS-485 2-wire  
operation on Port 1, set SW4-1 and 4-2 to ON. For RS-485 4-wire operation,  
regardless of the interface, SW4-3 and SW4-8 are always set to ON. Pull-down  
resistor (PD) for Port 1 (SW4-4) and pull-up resistor (PU) for Port 1 (SW4-5) can  
also be set to ON or OFF for RS-422 or RS-485. Pull-down resistor (PD) for Port 2  
(SW4-9) and pull-up resistor (PU) for Port 2 (SW4-10) can also be set to ON or  
OFF for RS-422 or RS-485 operation.  
Figure 4-1. Switch SW4.  
NOTE  
Switch positions SW4-1, 2, 3, 4, and 5 are for Port 1. Switch positions  
SW4-6, 7, 8, 9, and 10 are for Port 2.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
Table 4-2. DIP-switch SW4 settings.  
Switch  
Setting  
Switch  
Number  
Port  
Description  
RS-485  
RS-422  
L
SW4-1  
SW4-2  
SW4-3  
SW4-4  
SW4-51  
SW4-6  
SW4-7  
SW4-8  
SW4-9  
SW4-10  
1
1
1
1
TX+ to RX+  
TX- to RX-  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
L
T
Termination  
1K Pull-Down  
PD  
PU  
L
OFF  
OFF  
OFF  
OFF  
ON  
1K Pull-Up  
2
2
2
2
2
TX+ to RX+  
TX- to RX-  
L
T
Termination  
1K Pull-Down  
1K Pull-Up  
PD  
PU  
OFF  
OFF  
L = Loops TX+ to RX+ or RX- to TX- for two-wire operation.  
T = Adds a 120-ohm termination resistor between RX+ and RX-.  
PU = Pull-up. Adds a 1 K-ohm pull-up resistor to RX+.  
PD = Pull-down. Adds a 1 K-ohm pull-down resistor to RX-.  
Switch SW3 Settings  
To select RS-485 mode (4-wire or 2-wire operation) or RS-422 mode (4-wire  
operation), set the DIP switch labeled SW3 on the circuit board. (See Figure 4-2  
and Table 4-3.)  
Figure 4-2. RS-422/ 485 interface configuration.  
NOTE  
Switch positions SW3-1 and SW3-2 are for Port 1 and switch positions  
SW3-3 and SW3-4 are for Port 2.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: Configuration  
Table 4-3. DIP-switch SW3 settings.  
Switch  
Setting  
Switch Port  
Number  
Description  
RS-485  
RS-422  
485SW3-1  
NE  
1
485 Mode  
(4-wire)  
ON  
OFF  
OFF  
OFF  
OFF  
SW3-2  
2
1
2
485 Mode, No Echo (2-wire) ON  
485 Mode (4-wire) ON  
485 Mode, No Echo (2-wire) ON  
485SW3-3  
NE  
SW3-4  
NE = No Echo. In a two-wire setup, the receiver will not echo back the transmitted  
data.  
4.2.2 QUAD-PORT USB HUB—RS-422/ 485 (IC1021A)  
Each of the four DB9 ports on the Quad-Port USB Hub can be set as either RS-422  
or RS-485. You do not need to set a jumper to select these options. Instead, you just  
need to set DIP-switches SW1, SW2, SW3, and SW4.  
Switch SW2 and SW4 Settings  
To select either RS-422 or RS-485, set the DIP switches labeled SW2 and SW4 on  
the circuit board (see Figure 4-3). Table 4-4 lists the possible settings for DIP-  
switches SW2 and SW4. You can also set termination, pull-up resistance, and pull-  
down resistance via these switches.  
Figure 4-3. Switches SW2 and SW4.  
NOTE  
Switch positions SW4-1, 2, 3, 4, and 5 are for Port 1. Switch positions  
SW4-6, 7, 8, 9, and 10 are for Port 2. Switch positions SW2-1, 2, 3, 4, and  
5 are for Port 3. Switch positions SW2-6, 7, 8, 9, and 10 are for Port 4.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
Table 4-4. DIP-switches SW2 and SW4 settings.  
Switch  
Setting  
Switch  
Number  
Port  
Description  
RS-485  
RS-422  
L
SW2-1  
SW2-2  
SW2-3  
SW2-4  
SW2-53  
SW2-6  
SW2-7  
SW2-8  
SW2-9  
SW2-10  
SW4-1  
SW4-2  
SW4-3  
SW4-4  
SW4-51  
SW4-6  
SW4-7  
SW4-8  
SW4-9  
SW4-10  
3
3
3
3
TX+ to RX+  
TX- to RX-  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
L
T
Termination  
1K Pull-Down  
PD  
PU  
L
OFF  
1K Pull-Up  
ON  
OFF  
4
4
4
4
4
1
1
1
1
TX+ to RX+  
TX- to RX-  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
L
T
Termination  
1K Pull-Down  
1K Pull-Up  
PD  
PU  
L
OFF  
OFF  
OFF  
OFF  
ON  
TX+ to RX+  
TX- to RX-  
L
T
Termination  
1K Pull-Down  
PD  
PU  
L
OFF  
OFF  
OFF  
OFF  
ON  
1K Pull-Up  
2
2
2
2
2
TX+ to RX+  
TX- to RX-  
L
T
Termination  
1K Pull-Down  
1K Pull-Up  
PD  
PU  
OFF  
OFF  
L = Loops TX+ to RX+ for two-wire operation.  
T = Adds a 120-ohm termination resistor between RX+ and RX-.  
PU = Pull-up. Adds a 1 K-ohm pull-up resistor to RX+.  
PD = Pull-down. Adds a 1 K-ohm pull-down resistor to RX-.  
Switch SW1 and SW3 Settings  
To select RS-485 mode (4-wire or 2-wire operation) or RS-422 mode (4-wire  
operation), set the DIP switches labeled SW1 and SW3 on the circuit board.  
(See Figure 4-4 and Table 4-5.)  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: Configuration  
Figure 4-4. RS-422/ 485 interface configuration.  
NOTE  
Switch positions SW3-1 and 2 are for Port 1, SW3-3 and 4 are for Port 2,  
SW1-1 and 2 are for Port 3, and SW1-3 and 4 are for Port 4.  
Table 4-5. DIP-switch SW1 and SW3 settings.  
Switch  
Setting  
Switch Port  
Number  
Description  
RS-485  
RS-422  
485SW1-1  
NE  
3
485 Mode  
(4-wire)  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
SW1-2  
4
3
4
1
2
485 Mode, No Echo (2-wire) ON  
485 Mode (4-wire) ON  
485 Mode, No Echo (2-wire) ON  
485 Mode (4-wire) ON  
485 Mode, No Echo (2-wire) ON  
485 Mode (4-wire) ON  
485 Mode, No Echo (2-wire) ON  
485SW1-3  
NE  
SW1-4  
1
485SW3-1  
NE  
SW3-2  
2
485SW3-3  
NE  
SW3-4  
NE = No Echo. In a two-wire setup, the receiver will echo back all transmitted data.  
4.2.3 QUAD-PORT USB HUB—RS-232/ 422/ 485 (IC1022A)  
You have a variety of configuration options for the four DB9 ports on the Quad-  
Port USB Hub. You can set all ports as RS-232, all ports as RS-422, all ports as RS-  
485, or any combination of these interfaces. You also need to select termination  
(ON or OFF) for each port, and pull-up and pull-down resistors (ON or OFF) for  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
each port. When selecting a configuration for your Hub, refer to Tables 4-6  
through 4-8 and Figures 4-5 and 4-6.  
Jumpers E1, E2, E3, E4, E5, E6, E7, and E8  
To configure Port 1 on the Quad-Port USB Hub for RS-232, select Jumper E8 on  
the circuit board. To configure Port 2 for RS-232, select Jumper E5. To configure  
Port 3 for RS-232, select Jumper E4, and for Port 4, select Jumper E1. (See Table  
4-6 for all the jumper settings.)  
Table 4-6. Jumper settings.  
Jumper  
Port  
RS-232  
RS-422/ 485  
E1  
E2  
E3  
E4  
E52  
E6  
E7  
E8  
4
4
3
3
X
2
1
1
X
X
X
X
X
X
X
Switch SW2 and SW4 Settings  
To select RS-485 mode (4-wire or 2-wire operation) or RS-422 mode (4-wire  
operation), as well as termination, pull-up resistance, and pull-down resistance, set  
the DIP switches labeled SW2 and SW4 on the circuit board. (See Figure 4-5 and  
Table 4-7.)  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: Configuration  
Figure 4-5. Switches SW2 and SW4.  
NOTE  
Switch positions SW4-1, 2, 3, 4, and 5 are for Port 1. Switch positions  
SW4-6, 7, 8, 9, and 10 are for Port 2. Switch positions SW2-1, 2, 3, 4, and  
5 are for Port 3. Switch positions SW2-6, 7, 8, 9, and 10 are for Port 4.  
Table 4-7. DIP-switches SW2 and SW4 settings.  
Switch  
Setting  
Switch  
Number  
Port  
Description  
RS-485  
RS-422  
L
SW2-1  
SW2-2  
SW2-3  
SW2-4  
SW2-53  
SW2-6  
SW2-7  
SW2-8  
SW2-9  
SW2-10  
SW4-1  
SW4-2  
SW4-3  
SW4-4  
SW4-51  
SW4-6  
SW4-7  
SW4-8  
3
3
3
3
TX+ to RX+  
TX- to RX-  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
L
T
Termination  
1K Pull-Down  
PD  
PU  
L
OFF  
1K Pull-Up  
ON  
OFF  
4
4
4
4
4
1
1
1
1
TX+ to RX+  
TX- to RX-  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
L
T
Termination  
1K Pull-Down  
1K Pull-Up  
PD  
PU  
L
OFF  
OFF  
OFF  
OFF  
ON  
TX+ to RX+  
TX- to RX-  
L
T
Termination  
1K Pull-Down  
PD  
PU  
L
OFF  
OFF  
OFF  
OFF  
ON  
1K Pull-Up  
2
2
2
TX+ to RX+  
TX- to RX-  
Termination  
L
T
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
Table 4-7 (continued). DIP-switches SW2 and SW4 settings.  
Switch  
Setting  
Switch  
Number  
Port  
Description  
RS-485  
RS-422  
PD  
PU  
SW4-9  
2
2
1K Pull-Down  
1K Pull-Up  
ON  
ON  
OFF  
OFF  
SW4-10  
L = Loops TX+ to RX+ for two-wire operation.  
T = Adds a 120-ohm termination resistor between RX+ and RX-.  
PU = Pull-up. Adds a 1 K-ohm pull-up resistor to RX+.  
PD = Pull-down. Adds a 1 K-ohm pull-down resistor to RX-.  
Switch SW1 and SW3 Settings  
To select RS-485 mode (4-wire or 2-wire operation) or RS-422 mode (4-wire  
operation), set the DIP switches labeled SW1 and SW3 on the circuit board.  
(See Figure 4-6 and Table 4-8.)  
Figure 4-6. RS-422/ 485 interface configuration.  
NOTE  
Switch positions SW3-1 and 2 are for Port 1, and switch positions SW3-3  
and 4 are for Port 2. Switch positions SW1-1 and 2 are for Port 3, and  
switch positions SW1-3 and 4 are for Port 4.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 4: Configuration  
Table 4-8. DIP-switch SW1 and SW3 settings.  
Switch  
Setting  
Switch Port  
Number  
Description  
RS-485  
RS-422  
485SW1-1  
NE  
3
485 Mode  
(4-wire)  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
SW1-2  
4
3
4
1
2
485 Mode, No Echo (2-wire) ON  
485 Mode (4-wire) ON  
485 Mode, No Echo (2-wire) ON  
485 Mode (4-wire) ON  
485 Mode, No Echo (2-wire) ON  
485 Mode (4-wire) ON  
485 Mode, No Echo (2-wire) ON  
485SW1-3  
NE  
SW1-4  
1
485SW3-1  
NE  
SW3-2  
2
485SW3-3  
NE  
SW3-4  
NE = No Echo. In a two-wire setup, the receiver will echo back all transmitted data.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
Appendix A. Troubleshooting  
A.1 Troubleshooting Tips  
Serial Utility test software is supplied on the included CD-ROM and will be used in  
the troubleshooting procedures. By using this software and following these simple  
steps, you can eliminate most common problems without calling Technical  
Support.  
1. If your Hub isnt working, first check to make sure that USB support is  
enabled in the System BIOS and that it’s functioning properly in the  
operating system. Use either the Windows 98/ Me or Windows 2000 Device  
Manager to do this.  
2. Make sure that the included software (from the CD-ROM) has been installed  
on the machine and that the necessary files are in place to complete the  
installation.  
3. When the USB Hub is configured properly, the USB Enabled LED (E) will be  
lit. This should allow you to use the WinSSD utility (from the CD-ROM ) and  
a loopback plug (not included) to check communications. The loopback plug  
connects TD to RD. If you decide to test the modem control signals, a full-pin  
loopback plug will be required. Details on loopback plugs are included on  
WinSSD. (A loopback plug is available by special order from Black Box. Call  
Technical Support for details.)  
4. When testing the USB Hub in loopback mode, the port LEDs will flash and  
echoed data will appear on the screen. The loopback test first transmits a hex  
pattern, 55AA, and then a ASCII string of data. If this test passes, then the  
USB Hub is ready for use in your application.  
5. Please note that if the USB Hub is configured for 2-wire RS-485 with no echo,  
a loopback test is not possible. The receiver, in this case, will be turned off  
and the test will fail. If you plan on using this device in two-wire mode, test the  
Hub in RS-422 mode first. Then configure the Hub for your application.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX A: Troubleshooting  
A.2 Calling Black Box  
If you determine that your USB Hub is malfunctioning, do not attempt to alter or  
repair the unit. It contains no user-serviceable parts. Contact Black Box at  
724-746-5500.  
Before you do, make a record of the history of the problem. We will be able to  
provide more efficient and accurate assistance if you have a complete description,  
including:  
• the nature and duration of the problem.  
• when the problem occurs.  
• the components involved in the problem.  
• any particular application that, when used, appears to create the problem or  
make it worse.  
A.3 Shipping and Packaging  
If you need to transport or ship your USB Hub:  
• Package it carefully. We recommend that you use the original container.  
• If you are shipping the USB Hub for repair, make sure you include everything  
that came in the original package. Before you ship, contact Black Box to get a  
Return Authorization (RA) number.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
Appendix B. Electrical Interfaces  
B.1 RS-232  
Quite possibly the most widely used communication standard is RS-232. This  
implementation has been defined and revised several times and is often referred  
to as EIA/ TIA-232.  
The IBM® PC AT® computer defined the RS-232 port on a DB9 connector, and  
subsequently the EIA/ TIA approved this implementation as the EIA/ TIA-574  
standard. This standard is defined as the 9-Position Non-Synchronous Interface between  
Data Terminal Equipment and Data Circuit-Terminating Equipment Employing Serial  
Binary Data Interchange. Both implementations are in widespread use and are  
referred to as RS-232 in this document.  
RS-232 is capable of operating at data rates up to 20 kbps at distances less than  
50 ft. (15.2 m). The absolute maximum data rate may vary due to line conditions  
and cable lengths. RS-232 is a single-ended or unbalanced interface, meaning that  
a single electrical signal is compared to a common signal (ground) to determine  
binary logic states. The RS-232 and the EIA/ TIA-574 specification define two types  
of interface circuits: Data Terminal Equipment (DTE) and Data Circuit-  
Terminating Equipment (DCE). The USB Hub is a DTE device.  
B.2 RS-422  
The RS-422 specification defines the electrical characteristics of balanced-voltage  
digital interface circuits. RS-422 is a differential interface that defines voltage levels  
and driver/ receiver electrical specifications.  
On a differential interface, logic levels are defined by the difference in voltage  
between a pair of outputs or inputs. In contrast, a single-ended interface, for  
example RS-232, defines the logic levels as the difference in voltage between a  
single signal and a common ground connection.  
Differential interfaces are typically more immune to noise or voltage spikes that  
may occur on the communication lines. Differential interfaces also have greater  
drive capabilities that allow for longer cable lengths. RS-422 is rated up to 10 Mbps  
and can have cabling 4000 feet (1219.2 m) long. RS-422 also defines driver and  
receiver electrical characteristics that will allow 1 driver and up to 32 receivers on  
the line at once. RS-422 signal levels range from 0 to +5 volts. RS-422 does not  
define a physical connector.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX B: Electrical Interfaces  
B.3 RS-485  
RS-485 is backward-compatible with RS-422; however, it is optimized for partyline  
or multidrop applications. The output of the RS-422/ 485 driver is capable of being  
Active (enabled) or Tristate (disabled). This capability allows multiple ports to be  
connected in a multidrop bus and selectively polled.  
RS-485 allows cable lengths up to 4000 feet (1219.2 m) and data rates up to  
10 Mbps. The signal levels for RS-485 are the same as those defined by RS-422.  
RS-485 has electrical characteristics that allow for 32 drivers and 32 receivers to  
be connected to one line. This interface is ideal for multidrop or network  
environments. RS-485’s tristate (not dual-state) driver will allow the electrical  
presence of the driver to be removed from the line. Only one driver may be active  
at a time, and the other driver(s) must be tristated.  
RS-485 can be cabled in two ways: two-wire and four-wire mode. Two-wire mode  
does not allow for full-duplex communication, so data can be transferred in only  
one direction at a time. For half-duplex operation, the two transmit pins should be  
connected to the two receive pins (Tx+ to Rx+ and Tx to Rx). Four-wire mode  
allows full-duplex data transfers.  
RS-485 does not define a connector pinout, a physical connector, or a set of  
modem control signals.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUAL- AND QUAD-PORT USB HUBS  
Appendix C:  
Asynchronous Communication  
In serial data communication, individual bits of a character are transmitted  
consecutively to a receiver that assembles the bits back into a character. Data rate,  
error checking, handshaking, and character framing (start/ stop bits) are pre-  
defined and must correspond at both the transmitting and receiving ends.  
Asynchronous communication is the standard means of serial data  
communication for PC compatibles and PS/ 2® computers. The original PC  
was equipped with a communication or COM port that was designed around an  
8250 Universal Asynchronous Receiver Transmitter (UART). This device allows  
asynchronous serial data to be transferred through a simple and straightforward  
programming interface. A start bit, followed by a pre-defined number of data bits  
(5, 6, 7, or 8), defines character boundaries for asynchronous communication. The  
end of the character is defined by the transmission of a pre-defined number  
of stop bits (usually 1, 1.5, or 2).  
Figure C-1. Bit diagram for asynchronous communication.  
An extra bit used for error detection is often appended before the stop bits.  
This special bit is called the parity bit. Parity is a simple method of determining  
if a data bit has been lost or corrupted during transmission. There are several  
methods for implementing a parity check to guard against data corruption.  
Common methods are called (E)ven Parity or (O)dd Parity. Sometimes parity  
is not used to detect errors on the data stream. This is refereed to as (N)o parity.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX C: Asynchronous Communication  
Because each bit in asynchronous communication is sent consecutively, it is easy to  
generalize asynchronous communication by stating that each character is wrapped  
(framed) by pre-defined bits to mark the beginning and end of the serial  
transmission of the character. The data rate and communication parameters for  
asynchronous communication have to be the same at both the transmitting and  
receiving ends. The communication parameters are baud rate, parity, number of  
data bits per character, and stop bits (usually listed in that order, like this:  
9600,N,8,1).  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
© Copyright 2002. Black Box Corporation. All rights reserved.  
1000 Park Drive  
Lawrence, PA 15055-1018  
724-746-5500  
Fax 724-746-0746  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Blackberry Cell Phone BB9630TOUR User Manual
Black Decker Vacuum Cleaner NV2410N User Manual
Bogen Stereo System RPK79 User Manual
Bolens Lawn Mower 115 040A User Manual
Bose Stereo System wave music system ic 1 User Manual
Boss Audio Systems Speaker P156DVC User Manual
Brother Printer Series HL 1800 User Manual
Cadco Food Warmer CBC 2RT User Manual
Casio Projector Accessories XJ SK600 User Manual
Centurion Oxygen Equipment CP72SR5 User Manual