Black Box Portable Media Storage QCE12U User Manual

QCE12U  
QCE24U  
QCE42U  
QCE-CEB  
QCE-GK  
QCE-SPFP-1U  
QCE-SPFP-2U  
QCE-SPFP-3U  
QCE-SPFP-5U  
QCE-VCM-24U
QCE-VCM-42U
QCE-DF-12U  
QCE-DF-24U  
QCE-DF-42U  
QuietCabElite12U, 24U, and 42U User Manual  
Reduce noise and improve productivity  
in your office with QuietCab soundproof data  
cabinets.  
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)  
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax  
724-746-0746 • Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence,  
PA 15055-1018 • Web site: www.blackbox.com • E-mail: [email protected]  
Customer  
Support  
Information  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC and IC RFI Statements and NOM Statement  
FEDERAL COMMUNICATIONS COMMISSION AND  
INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS  
This equipment generates, uses, and can radiate radio-frequency energy,  
and if not installed and used properly, that is, in strict accordance with the  
manufacturer’s instructions, may cause interference to radio communication.  
It has been tested and found to comply with the limits for a Class A computing  
device in accordance with the specifications in Subpart B of Part 15 of FCC rules,  
which are designed to provide reasonable protection against such interference  
when the equipment is operated in a commercial environment. Operation of  
this equipment in a residential area is likely to cause interference, in which case  
the user at his own expense will be required to take whatever measures may be  
necessary to correct the interference.  
Changes or modifications not expressly approved by the party responsible  
for compliance could void the user’s authority to operate the equipment.  
This digital apparatus does not exceed the Class A limits for radio noise  
emission from digital apparatus set out in the Radio Interference Regulation  
of Industry Canada.  
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les  
limites applicables aux appareils numériques de la classe A prescrites dans le  
Règlement sur le brouillage radioélectrique publié par Industrie Canada.  
Normas Oficiales Mexicanas (NOM)  
Electrical Safety Statement  
INSTRUCCIONES DE SEGURIDAD  
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que  
el aparato eléctrico sea operado.  
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia  
futura.  
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación  
deben ser respetadas.  
Page 3  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOM Statement  
4. Todas las instrucciones de operación y uso deben ser seguidas.  
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo,  
cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca,  
etc.  
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales  
que sean recomendados por el fabricante.  
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea  
recomendado por el fabricante.  
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá  
lo descrito en las instrucciones de operación. Todo otro servicio deberá ser  
referido a personal de servicio calificado.  
9. El aparato eléctrico debe ser situado de tal manera que su posición no  
interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá,  
alfombra o superficie similar puede bloquea la ventilación, no se debe  
colocar en libreros o gabinetes que impidan el flujo de aire por los orificios  
de ventilación.  
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor  
como radiadores, registros de calor, estufas u otros aparatos (incluyendo  
amplificadores) que producen calor.  
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del  
tipo descrito en el instructivo de operación, o como se indique en el  
aparato.  
12. Precaución debe ser tomada de tal manera que la tierra fisica y la  
polarización del equipo no sea eliminada.  
13. Los cables de la fuente de poder deben ser guiados de tal manera que no  
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,  
poniendo particular atención a los contactos y receptáculos donde salen  
del aparato.  
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las  
recomendaciones del fabricante.  
15. En caso de existir, una antena externa deberá ser localizada lejos de las  
lineas de energia.  
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea  
usado por un largo periodo de tiempo.  
Page 4  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOM Statement  
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean  
derramados sobre la cubierta u orificios de ventilación.  
18. Servicio por personal calificado deberá ser provisto cuando:  
A: El cable de poder o el contacto ha sido dañado; u  
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o  
C: El aparato ha sido expuesto a la lluvia; o  
D: El aparato parece no operar normalmente o muestra un cambio en su  
desempeño; o  
E: El aparato ha sido tirado o su cubierta ha sido dañada.  
Page 5  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Table of Contents  
1. Specifications..............................................................................................7  
2. Overview.....................................................................................................8  
2.1 Introduction......................................................................................8  
2.2 Features............................................................................................8  
2.3 What’s Included................................................................................8  
3. Preparing the Cabinet for Installation..........................................................9  
3.1 Handling...........................................................................................9  
3.2 What Tools Will I Need? ...................................................................9  
3.3 Where Can I Put the Cabinet?..........................................................9  
3.4 Removing the Cladding ....................................................................9  
3.5 Thermal Considerations ..................................................................10  
3.6 Cable Management........................................................................ 11  
3.7 Additional Accessories....................................................................16  
Page 6  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Specifications  
1. Specifications  
Attenuation — Up to 28.5 dB  
Cable Knockout Size — Top panel: (3) 3"x 13" (7.62 x 33.02 cm);  
Bottom panel: (3) 3" x 13" (7.62 x 33.02 cm)  
Capacity — 1102.3 lb. (500 kg)  
Fans — (2) 740 CFM total  
Footprint, Cladding — 30.7"W x 47.6"D (78 x 121 cm)  
Footprint, Floor — 30.7"W x 43.3"D (78 x 110 cm)  
Heat Load (Maximum) — 7.2 kW  
Power Consumption (Maximum) — 1 Amp  
Rack Units — 12  
RoHS — Yes  
Size — QCE12U: External: 28"H x 30.7"W x 47.63"D (71.12 x 77.97 x 120.98 cm),  
Internal: 21"H x 19"W x 33.47"D (53.34 x 48.26 x 85.01 cm);  
QCE24U: External: 49.21"H x 30.7"W x 47.63"D (124.9 x 77.97 x 120.98 cm),  
Internal: 42"H x 19"W x 33.47"D (106.68 x 48.26 x 85.01 cm);  
QCE42U: External: 80.7"H x 30.7"W x 47.63"D (204.97 x 77.97 x 120.98 cm),  
Internal: 73.5"H x 19"W x 33.47"D (186.69 x 48.26 x 85.01 cm)  
Weight — QCE12U: 260 lb. (118 kg);  
QCE24U: 394 lb. (179.1 kg);  
QCE42U: 657 lb. (298.6 cm)  
Page 7  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Overview  
2. Overview  
2.1 Introduction  
The QuietCab Elite reduces equipment noise to a level below background noise in  
an average office. It attenuates sound by 28.5 dB—the most you can get today in  
a soundproof enclosure. Independently tested as the most effective quiet cabinet  
in the world, the QuietCab Elite features an innovative airflow design with 7.2 kW  
heat dissipation—the equivalent of 37 single processor servers and peripherals.  
Use the QuietCab in environments where you need to store network equipment  
near workers, such as offices, schools, medical offices, retail establishments, and  
more.  
2.2 Features  
• Reduces noise without compromising cooling capability.  
• Handles higher heat loads with variable fan speed control and a temperature  
sensor for maximum energy efficiency. (Fan speed controller is not UL® listed.)  
• 19" M6 rails are adjustable.  
• Rear doors feature two exhaust fans (370 CFM each).  
• Generous cable management space is built in.  
• Accommodates all leading servers, including blade servers.  
• Lockable front and rear doors keeps equipment safe and secure.  
• Includes casters.  
• 12U, 24U, and 42U models are available.  
• Patent-pending design.  
2.3 What’s Included  
Your package should include the following items. If anything is missing  
or damaged, contact Black Box Technical Support at 724-746-5500  
• QuietCab Elite 12U, 24U, or 42U  
• Casters  
• (1) cable entry box with foam inserts  
• (2) foam inserts, 20.5" x 1.375" x 1.625" (52.07 x 3.49 x 4.13 cm)  
• (9) pairs of keys  
• This user’s manual  
NOTE: Mounting hardware is not included.  
Page 8  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Preparing the Cabinet for Installation  
3. Preparing the Cabinet for Installation  
Follow these simple recommendations for best performance from your new  
enclosure.  
3.1 Handling  
NOTE: For palletized cabinets, see the unpacking instruction sheet before  
attempting to remove the cabinet from the pallet.  
To achieve the level of acoustic performance and industrial needs of a high-quality  
19” enclosure, the composition of cabinet parts means that the QuietCab Elite  
cabinets are very heavy. When moving the cabinet, we recommend that a  
minimum of two people carry out this task.  
The individual doors and side panels are also very heavy and need to be handled  
with care.  
3.2 What Tools Will I Need?  
• 2-point pozi drive screwdriver  
• 10-mm ratchet and socket  
3.3 Where Can I Put the Cabinet?  
Be careful when choosing a site for the passive and active cabinets.  
1. Don’t place cabinets next to room heating sources, for example, radiators.  
2. Don’t place cabinets near windows (to avoid solar gain).  
3. If possible, place cabinets in an air-conditioned room or in a well-ventilated  
space.  
4. Check floor loading capacity. Consider the weight combination of both the  
cabinet and equipment housed.  
3.4 Removing the Cladding  
CAUTION: We recommend that a minimum of two people remove and assemble  
the cladding onto the cabinet.  
1. To remove front passive wardrobe doors, turn the cam lock with the key  
supplied, then lift the swing handle and turn clockwise. Open doors without  
disturbing soundproof seals.  
2. When doors are open, lift each side individually just high enough to clear hinge  
pins and safely stand the door against a solid wall.  
Page 9  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Preparing the Cabinet for Installation  
3. To remove rear doors, disconnect the power supply, turn the cam lock with key  
supplied, then lift the swing handle and turn it clockwise. Hold the left-hand  
door in position while opening the right-hand door.  
NOTE: Open without disturbing the sound-proof seals.  
4. Each door has a cooling fan connected to a fan-speed controller placed behind  
the side infills.  
CAUTION: Make sure that the fan speed controller is NOT connected to its supply  
BEFORE removing the rear door. Note the polarization of the  
connector so you can connect it later.  
5. Disconnect each fan at the rear of the door by squeezing the retaining clips on  
the white connectors and pulling them apart. When the doors are open and  
the main door is away from the frame, lift off each door and safely stand it  
against a solid wall.  
6. To re-hang the rear doors, reverse the procedure above.  
NOTE: Remember to refit the fan connectors after reassembling the doors to the  
cabinet and then reconnect the power supply.  
To remove the side panels, simply turn the cam locks with the keys supplied and  
lift the panel and place against a solid wall.  
WARNING: Again, the panels are very heavy. We recommend that a minimum of  
two people work together to remove the side panels.  
3.5 Thermal Considerations  
To maximize the thermal capabilities of the QuietCab Elite, we strongly  
recommend filling all spaces on and around the front 19” area.  
Sealing the front face of the 19” area keeps hot air from recirculating. Any air  
gaps will impact the amount of heat removed from the cabinet.  
Fill the empty space on the 19” area with soundproof 19” quick-fit blanking  
panels; see the selection of sizes in Table 3-1.  
There is a gap above and below the 19” area even after all the equipment and  
blanking panels have been fitted. We recommend filling this space using the 19"  
infill foam supplied with the cabinet (see Figure 3-3).  
Page 10  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Preparing the Cabinet for Installation  
CAUTION: Make sure that once fitted, the foam does not cover any of the  
equipment’s vents.  
Table 3-1. Quick fit soundproof blanking panels.  
Rack Units  
Description  
Part Number  
1U  
1U high, 19" wide filler panel  
QCE-SPFP-1U  
2U  
3U  
5U  
2U high, 19" wide filler panel  
3U high, 19" wide filler panel  
4U high, 19" wide filler panel  
QCE-SPFP-2U  
QCE-SPFP-3U  
QCE-SPFP-5U  
The cabling runs from the front 19" face to the rear of the cabinet via the top  
and bottom of the left-hand and right-hand infills once installation is finished or  
following any refits. Fill the resulting air gaps around the cabling with the supplied  
infill foam (see Figure 3-3).  
3.6 Cable Management  
The QuietCab Elite is fitted with six cable entry positions, three on both the lid  
and base, fitted to the rear and to each side of the cabinet (see Figure 3-1).  
Gland plates  
Gland plates  
Figure 3-1. The cabinet has three cable entry points via removable gland plates  
fitted to the top cover shown and three more fitted to the base.  
Page 11  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Preparing the Cabinet for Installation  
Cables are usually run into the side cable apertures of a cabinet and straight onto  
cable trays fitted to the cabinet frame (see Figure 3-5). With the interconnecting  
server and equipment, cables are dressed to the side and rear.  
Most equipment fans expel hot waste air to the rear of the cabinet.. Disorganized  
cabling can inhibit airflow movement, so be careful when dressing cabling. We  
recommend that cables are dressed to the side rear infill panels.  
Fitting a cable entry box (QCE-CEB)  
Select a cable entry point and remove four M6 screws. Then remove the gland  
plate.  
The gland plate will also be held in place by the adhesive stuck to the soundproof  
material; this means some force may be required to remove the gland plate. The  
soundproof material is partly precut and will require only the adhesive layer to be  
cut by a sharp blade before being removed.  
One cable entry box (see Figure 3-2) is supplied with each cabinet. If you need  
more cable entry boxes, contact Black Box Technical Support at 724-746-5500  
Figure 3-2. Cable entry box (QCE-CEB).  
Page 12  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Preparing the Cabinet for Installation  
The cable entry box is reassembled in the hole exposed by removing the gland  
and soundproofing material. Assemble it from the inside of the cabinet so that  
the flange makes a seal on the cabinet’s soundproofing material showing rear  
center base assembled. Make sure foam is dressed around cables so that no air  
can escape. This will ensure that any airborne sound inside the cabinet is retained  
and attenuated within the enclosure. We recommend that the cables, where pos-  
sible, lay flat to avoid bunching.  
For front-to-rear cable management, pass the cable through the front-to-rear  
foam blocks (see Figure 3-3). These are positioned to the top and bottom of the  
front infill panels on each side of the cabinet.  
Figure 3-3. Front-to-rear cable infill foam. Top right hand side front shown.  
Page 13  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Preparing the Cabinet for Installation  
Two foam inserts are supplied as standard and should be fitted, regardless of  
cables being passed though, because this ensures the correct air path for cooling.  
Keep cable bundle flat where possible when passing through foam blocks.  
Figure 3-4. Cable entry box. Rear base shown.  
NOTE: Keep cables flat where possible.  
Middle side vertical cable management is achieved by fitting a cable tray (not  
included) to the cabinet depth support members fixed to the front and rear corner  
posts (see Figure 3-5).  
NOTE: Table 3-2 lists cable tray sizes.  
Page 14  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Preparing the Cabinet for Installation  
Figure 3-5. Cable tray.  
Page 15  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Preparing the Cabinet for Installation  
Table 3-2. Available cable trays.  
Rack Units  
Description  
Part Number  
12U  
5.9" (150 mm) wide  
*Contact Tech Support.  
24U  
24U  
42U  
42U  
5.9" (150 mm) wide  
5.9" (150 mm) wide  
5.9" (150 mm) wide  
5.9" (150 mm) wide  
*Contact Tech Support.  
*Contact Tech Support.  
*Contact Tech Support.  
*Contact Tech Support.  
*Contact Black Box Technical Support at 724-746-5500 or [email protected].  
These along with other accessories can be purchased from Black Box. Contact  
Technical Support at 724-746-5500 or [email protected].  
3.7 Additional Accessories  
Table 3-3. Dust filters.  
Rack Units  
Part Number  
12U  
QCE-DF-12U.  
24U  
24U  
QCE-DF-24U  
QCE-DF-42U  
Table 3-4. Vertical cable managers.  
Rack Units  
Part Number  
24U  
QCE-VCM-24U  
24U  
QCE-VCM-42U  
Table 3-5. Grounding kit..  
Rack Units  
12U, 24U, 42U  
Part Number  
QCE-GK  
Page 16  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Page 17  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Page 18  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Page 19  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Black Box Tech Support: FREE! Live. 24/7.  
Tech support the  
way it should be.  
Great tech support is just 30 seconds away at  
724-746-5500 or blackbox.com.  
About Black Box  
Black Box provides an extensive range of networking and infrastructure products.  
You’ll find everything from cabinets and racks and power and surge protection  
products to media converters and Ethernet switches all supported by free, live 24/7  
Tech support available in 30 seconds or less.  
© Copyright 2012. Black Box Corporation. All rights reserved.  
QCE12U User Manual, version 2  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bosch Power Tools Router PR10E User Manual
Braun Electric Shaver 5413 User Manual
Briggs Stratton Lawn Mower NSPVH21675 User Manual
Briggs Stratton Portable Generator Home Generator Systems User Manual
Canon Camcorder 500 HS User Manual
Canon Printer C5800 User Manual
Carson Optical Binoculars XM Series User Manual
Casablanca Fan Company Outdoor Ceiling Fan C31UxxZ User Manual
Casio Clock MA0302 A User Manual
Chromalox Electric Heater GS User Manual