QCE12U
QCE24U
QCE42U
QCE-CEB
QCE-GK
QCE-SPFP-1U
QCE-SPFP-2U
QCE-SPFP-3U
QCE-SPFP-5U
QCE-VCM-24U
QCE-VCM-42U
QCE-DF-12U
QCE-DF-24U
QCE-DF-42U
QuietCabElite12U, 24U, and 42U User Manual
Reduce noise and improve productivity
in your office with QuietCab soundproof data
cabinets.
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax
724-746-0746 • Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence,
Customer
Support
Information
Download from Www.Somanuals.com. All Manuals Search And Download.
FCC and IC RFI Statements and NOM Statement
FEDERAL COMMUNICATIONS COMMISSION AND
INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio-frequency energy,
and if not installed and used properly, that is, in strict accordance with the
manufacturer’s instructions, may cause interference to radio communication.
It has been tested and found to comply with the limits for a Class A computing
device in accordance with the specifications in Subpart B of Part 15 of FCC rules,
which are designed to provide reasonable protection against such interference
when the equipment is operated in a commercial environment. Operation of
this equipment in a residential area is likely to cause interference, in which case
the user at his own expense will be required to take whatever measures may be
necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise
emission from digital apparatus set out in the Radio Interference Regulation
of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les
limites applicables aux appareils numériques de la classe A prescrites dans le
Règlement sur le brouillage radioélectrique publié par Industrie Canada.
Normas Oficiales Mexicanas (NOM)
Electrical Safety Statement
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que
el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia
futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación
deben ser respetadas.
Page 3
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
NOM Statement
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo,
cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca,
etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales
que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea
recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá
lo descrito en las instrucciones de operación. Todo otro servicio deberá ser
referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no
interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá,
alfombra o superficie similar puede bloquea la ventilación, no se debe
colocar en libreros o gabinetes que impidan el flujo de aire por los orificios
de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor
como radiadores, registros de calor, estufas u otros aparatos (incluyendo
amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del
tipo descrito en el instructivo de operación, o como se indique en el
aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la
polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,
poniendo particular atención a los contactos y receptáculos donde salen
del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las
recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las
lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea
usado por un largo periodo de tiempo.
Page 4
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
NOM Statement
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean
derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su
desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
Page 5
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Table of Contents
1. Specifications..............................................................................................7
2. Overview.....................................................................................................8
2.1 Introduction......................................................................................8
2.2 Features............................................................................................8
2.3 What’s Included................................................................................8
3. Preparing the Cabinet for Installation..........................................................9
3.1 Handling...........................................................................................9
3.2 What Tools Will I Need? ...................................................................9
3.3 Where Can I Put the Cabinet?..........................................................9
3.4 Removing the Cladding ....................................................................9
3.5 Thermal Considerations ..................................................................10
3.6 Cable Management........................................................................ 11
3.7 Additional Accessories....................................................................16
Page 6
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Specifications
1. Specifications
Attenuation — Up to 28.5 dB
Cable Knockout Size — Top panel: (3) 3"x 13" (7.62 x 33.02 cm);
Bottom panel: (3) 3" x 13" (7.62 x 33.02 cm)
Capacity — 1102.3 lb. (500 kg)
Fans — (2) 740 CFM total
Footprint, Cladding — 30.7"W x 47.6"D (78 x 121 cm)
Footprint, Floor — 30.7"W x 43.3"D (78 x 110 cm)
Heat Load (Maximum) — 7.2 kW
Power Consumption (Maximum) — 1 Amp
Rack Units — 12
RoHS — Yes
Size — QCE12U: External: 28"H x 30.7"W x 47.63"D (71.12 x 77.97 x 120.98 cm),
Internal: 21"H x 19"W x 33.47"D (53.34 x 48.26 x 85.01 cm);
QCE24U: External: 49.21"H x 30.7"W x 47.63"D (124.9 x 77.97 x 120.98 cm),
Internal: 42"H x 19"W x 33.47"D (106.68 x 48.26 x 85.01 cm);
QCE42U: External: 80.7"H x 30.7"W x 47.63"D (204.97 x 77.97 x 120.98 cm),
Internal: 73.5"H x 19"W x 33.47"D (186.69 x 48.26 x 85.01 cm)
Weight — QCE12U: 260 lb. (118 kg);
QCE24U: 394 lb. (179.1 kg);
QCE42U: 657 lb. (298.6 cm)
Page 7
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Overview
2. Overview
2.1 Introduction
The QuietCab Elite reduces equipment noise to a level below background noise in
an average office. It attenuates sound by 28.5 dB—the most you can get today in
a soundproof enclosure. Independently tested as the most effective quiet cabinet
in the world, the QuietCab Elite features an innovative airflow design with 7.2 kW
heat dissipation—the equivalent of 37 single processor servers and peripherals.
Use the QuietCab in environments where you need to store network equipment
near workers, such as offices, schools, medical offices, retail establishments, and
more.
2.2 Features
• Reduces noise without compromising cooling capability.
• Handles higher heat loads with variable fan speed control and a temperature
sensor for maximum energy efficiency. (Fan speed controller is not UL® listed.)
• 19" M6 rails are adjustable.
• Rear doors feature two exhaust fans (370 CFM each).
• Generous cable management space is built in.
• Accommodates all leading servers, including blade servers.
• Lockable front and rear doors keeps equipment safe and secure.
• Includes casters.
• 12U, 24U, and 42U models are available.
• Patent-pending design.
2.3 What’s Included
Your package should include the following items. If anything is missing
or damaged, contact Black Box Technical Support at 724-746-5500
• QuietCab Elite 12U, 24U, or 42U
• Casters
• (1) cable entry box with foam inserts
• (2) foam inserts, 20.5" x 1.375" x 1.625" (52.07 x 3.49 x 4.13 cm)
• (9) pairs of keys
• This user’s manual
NOTE: Mounting hardware is not included.
Page 8
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Preparing the Cabinet for Installation
3. Preparing the Cabinet for Installation
Follow these simple recommendations for best performance from your new
enclosure.
3.1 Handling
NOTE: For palletized cabinets, see the unpacking instruction sheet before
attempting to remove the cabinet from the pallet.
To achieve the level of acoustic performance and industrial needs of a high-quality
19” enclosure, the composition of cabinet parts means that the QuietCab Elite
cabinets are very heavy. When moving the cabinet, we recommend that a
minimum of two people carry out this task.
The individual doors and side panels are also very heavy and need to be handled
with care.
3.2 What Tools Will I Need?
• 2-point pozi drive screwdriver
• 10-mm ratchet and socket
3.3 Where Can I Put the Cabinet?
Be careful when choosing a site for the passive and active cabinets.
1. Don’t place cabinets next to room heating sources, for example, radiators.
2. Don’t place cabinets near windows (to avoid solar gain).
3. If possible, place cabinets in an air-conditioned room or in a well-ventilated
space.
4. Check floor loading capacity. Consider the weight combination of both the
cabinet and equipment housed.
3.4 Removing the Cladding
CAUTION: We recommend that a minimum of two people remove and assemble
the cladding onto the cabinet.
1. To remove front passive wardrobe doors, turn the cam lock with the key
supplied, then lift the swing handle and turn clockwise. Open doors without
disturbing soundproof seals.
2. When doors are open, lift each side individually just high enough to clear hinge
pins and safely stand the door against a solid wall.
Page 9
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Preparing the Cabinet for Installation
3. To remove rear doors, disconnect the power supply, turn the cam lock with key
supplied, then lift the swing handle and turn it clockwise. Hold the left-hand
door in position while opening the right-hand door.
NOTE: Open without disturbing the sound-proof seals.
4. Each door has a cooling fan connected to a fan-speed controller placed behind
the side infills.
CAUTION: Make sure that the fan speed controller is NOT connected to its supply
BEFORE removing the rear door. Note the polarization of the
connector so you can connect it later.
5. Disconnect each fan at the rear of the door by squeezing the retaining clips on
the white connectors and pulling them apart. When the doors are open and
the main door is away from the frame, lift off each door and safely stand it
against a solid wall.
6. To re-hang the rear doors, reverse the procedure above.
NOTE: Remember to refit the fan connectors after reassembling the doors to the
cabinet and then reconnect the power supply.
To remove the side panels, simply turn the cam locks with the keys supplied and
lift the panel and place against a solid wall.
WARNING: Again, the panels are very heavy. We recommend that a minimum of
two people work together to remove the side panels.
3.5 Thermal Considerations
To maximize the thermal capabilities of the QuietCab Elite, we strongly
recommend filling all spaces on and around the front 19” area.
Sealing the front face of the 19” area keeps hot air from recirculating. Any air
gaps will impact the amount of heat removed from the cabinet.
Fill the empty space on the 19” area with soundproof 19” quick-fit blanking
panels; see the selection of sizes in Table 3-1.
There is a gap above and below the 19” area even after all the equipment and
blanking panels have been fitted. We recommend filling this space using the 19"
infill foam supplied with the cabinet (see Figure 3-3).
Page 10
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Preparing the Cabinet for Installation
CAUTION: Make sure that once fitted, the foam does not cover any of the
equipment’s vents.
Table 3-1. Quick fit soundproof blanking panels.
Rack Units
Description
Part Number
1U
1U high, 19" wide filler panel
QCE-SPFP-1U
2U
3U
5U
2U high, 19" wide filler panel
3U high, 19" wide filler panel
4U high, 19" wide filler panel
QCE-SPFP-2U
QCE-SPFP-3U
QCE-SPFP-5U
The cabling runs from the front 19" face to the rear of the cabinet via the top
and bottom of the left-hand and right-hand infills once installation is finished or
following any refits. Fill the resulting air gaps around the cabling with the supplied
infill foam (see Figure 3-3).
3.6 Cable Management
The QuietCab Elite is fitted with six cable entry positions, three on both the lid
and base, fitted to the rear and to each side of the cabinet (see Figure 3-1).
Gland plates
Gland plates
Figure 3-1. The cabinet has three cable entry points via removable gland plates
fitted to the top cover shown and three more fitted to the base.
Page 11
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Preparing the Cabinet for Installation
Cables are usually run into the side cable apertures of a cabinet and straight onto
cable trays fitted to the cabinet frame (see Figure 3-5). With the interconnecting
server and equipment, cables are dressed to the side and rear.
Most equipment fans expel hot waste air to the rear of the cabinet.. Disorganized
cabling can inhibit airflow movement, so be careful when dressing cabling. We
recommend that cables are dressed to the side rear infill panels.
Fitting a cable entry box (QCE-CEB)
Select a cable entry point and remove four M6 screws. Then remove the gland
plate.
The gland plate will also be held in place by the adhesive stuck to the soundproof
material; this means some force may be required to remove the gland plate. The
soundproof material is partly precut and will require only the adhesive layer to be
cut by a sharp blade before being removed.
One cable entry box (see Figure 3-2) is supplied with each cabinet. If you need
more cable entry boxes, contact Black Box Technical Support at 724-746-5500
Figure 3-2. Cable entry box (QCE-CEB).
Page 12
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Preparing the Cabinet for Installation
The cable entry box is reassembled in the hole exposed by removing the gland
and soundproofing material. Assemble it from the inside of the cabinet so that
the flange makes a seal on the cabinet’s soundproofing material showing rear
center base assembled. Make sure foam is dressed around cables so that no air
can escape. This will ensure that any airborne sound inside the cabinet is retained
and attenuated within the enclosure. We recommend that the cables, where pos-
sible, lay flat to avoid bunching.
For front-to-rear cable management, pass the cable through the front-to-rear
foam blocks (see Figure 3-3). These are positioned to the top and bottom of the
front infill panels on each side of the cabinet.
Figure 3-3. Front-to-rear cable infill foam. Top right hand side front shown.
Page 13
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Preparing the Cabinet for Installation
Two foam inserts are supplied as standard and should be fitted, regardless of
cables being passed though, because this ensures the correct air path for cooling.
Keep cable bundle flat where possible when passing through foam blocks.
Figure 3-4. Cable entry box. Rear base shown.
NOTE: Keep cables flat where possible.
Middle side vertical cable management is achieved by fitting a cable tray (not
included) to the cabinet depth support members fixed to the front and rear corner
posts (see Figure 3-5).
NOTE: Table 3-2 lists cable tray sizes.
Page 14
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Preparing the Cabinet for Installation
Figure 3-5. Cable tray.
Page 15
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Preparing the Cabinet for Installation
Table 3-2. Available cable trays.
Rack Units
Description
Part Number
12U
5.9" (150 mm) wide
*Contact Tech Support.
24U
24U
42U
42U
5.9" (150 mm) wide
5.9" (150 mm) wide
5.9" (150 mm) wide
5.9" (150 mm) wide
*Contact Tech Support.
*Contact Tech Support.
*Contact Tech Support.
*Contact Tech Support.
*Contact Black Box Technical Support at 724-746-5500 or [email protected].
These along with other accessories can be purchased from Black Box. Contact
Technical Support at 724-746-5500 or [email protected].
3.7 Additional Accessories
Table 3-3. Dust filters.
Rack Units
Part Number
12U
QCE-DF-12U.
24U
24U
QCE-DF-24U
QCE-DF-42U
Table 3-4. Vertical cable managers.
Rack Units
Part Number
24U
QCE-VCM-24U
24U
QCE-VCM-42U
Table 3-5. Grounding kit..
Rack Units
12U, 24U, 42U
Part Number
QCE-GK
Page 16
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Page 17
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Page 18
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Page 19
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Tech Support: FREE! Live. 24/7.
Tech support the
way it should be.
Great tech support is just 30 seconds away at
724-746-5500 or blackbox.com.
About Black Box
Black Box provides an extensive range of networking and infrastructure products.
You’ll find everything from cabinets and racks and power and surge protection
products to media converters and Ethernet switches all supported by free, live 24/7
Tech support available in 30 seconds or less.
© Copyright 2012. Black Box Corporation. All rights reserved.
QCE12U User Manual, version 2
724-746-5500 | blackbox.com
Download from Www.Somanuals.com. All Manuals Search And Download.
|