Black Box Network Hardware BLACK BOX 16 Port Web Smart Gigabit Ethernet Switch User Manual

LGB616A  
16-Port Web Smart Gigabit Ethernet Switch  
This Web Smart switch provides  
sixteen 10-/100-/1000-Mbps ports.  
Supports Gigabit speed on all ports.  
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)  
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax  
Customer  
Support  
724-746-0746 • Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence,  
PA 15055-1018 • Web site: www.blackbox.com • E-mail: [email protected]  
Information  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOM Statement  
Normas Oficiales Mexicanas (NOM)  
Electrical Safety Statement  
INSTRUCCIONES DE SEGURIDAD  
1.Todas las instrucciones de seguridad y operación deberán ser leídas antes de  
que el aparato eléctrico sea operado.  
2. Las instrucciones de seguridad y operación deberán ser guardadas para  
referencia futura.  
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de  
operación deben ser respetadas.  
4. Todas las instrucciones de operación y uso deben ser seguidas.  
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo,  
cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca,  
etc.  
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales  
que sean recomendados por el fabricante.  
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea  
recomendado por el fabricante.  
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá  
lo descrito en las instrucciones de operación. Todo otro servicio deberá ser  
referido a personal de servicio calificado.  
9. El aparato eléctrico debe ser situado de tal manera que su posición no  
interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá,  
alfombra o superficie similar puede bloquea la ventilación, no se debe  
colocar en libreros o gabinetes que impidan el flujo de aire por los orificios  
de ventilación.  
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor  
como radiadores, registros de calor, estufas u otros aparatos (incluyendo  
amplificadores) que producen calor.  
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del  
tipo descrito en el instructivo de operación, o como se indique en el  
aparato.  
LGB616A  
Page 3  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOM Statement  
12. Precaución debe ser tomada de tal manera que la tierra fisica y la  
polarización del equipo no sea eliminada.  
13. Los cables de la fuente de poder deben ser guiados de tal manera que no  
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,  
poniendo particular atención a los contactos y receptáculos donde salen  
del aparato.  
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las  
recomendaciones del fabricante.  
15. En caso de existir, una antena externa deberá ser localizada lejos de las  
lineas de energia.  
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea  
usado por un largo periodo de tiempo.  
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean  
derramados sobre la cubierta u orificios de ventilación.  
18. Servicio por personal calificado deberá ser provisto cuando:  
A: El cable de poder o el contacto ha sido dañado; u  
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o  
C: El aparato ha sido expuesto a la lluvia; o  
D: El aparato parece no operar normalmente o muestra un cambio en su  
desempeño; o  
E: El aparato ha sido tirado o su cubierta ha sido dañada.  
LGB616A  
Page 4  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trademarks Used in this Manual  
Trademarks Used in this Manual  
Black Box and the Double Diamond logo are registered trademarks of  
BB Technologies, Inc.  
Internet Explorer is a registered trademark of Microsoft Corporation.  
UL is a registered trademark of Underwriters’ Laboratories.  
Any other trademarks mentioned in this manual are acknowledged to be  
the property of the trademark owners.  
Disclaimer  
Black Box Network Services shall not be liable for damages of any kind, including,  
but not limited to, punitive, consequential or cost of cover damages, resulting  
from any errors in the product information or specifications set forth in this  
document and Black Box Network Services may revise this document at any time  
without notice.  
LGB616A  
Page 5  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Table of Contents  
1. Specifications  
............................................................................... 8  
2. Overview  
2.1 Introduction  
2.2 Features  
............................................................................... 9  
............................................................................... 9  
............................................................................... 9  
2.3 What’s Included ............................................................................. 10  
2.4 Hardware Description..................................................................... 10  
3. Software Description ..............................................................................12  
3.1 Login  
..............................................................................12  
3.2 Configuration ..............................................................................13  
3.2.1 System ..............................................................................13  
3.2.2 Ports  
..............................................................................15  
3.2.2.1 Port Configuration....................................................15  
3.2.3 VLAN  
..............................................................................17  
3.2.3.1 Port Segmentation (VLAN) Configuration................17  
3.2.3.2 VLAN Setup..............................................................17  
3.2.3.3 VLAN Per Port Configuration ...................................18  
3.2.4 Aggregation......................................................................... 20  
3.2.4.1 Aggregation/Trunking Configuration ...................... 20  
3.2.5 LACP  
............................................................................. 20  
3.2.5.1 LACP Port Configuration......................................... 20  
3.2.6 RSTP  
..............................................................................21  
3.2.6.1 RSTP System Configuration ......................................21  
3.2.6.2 RSTP Port Configuration.......................................... 22  
3.2.7 IGMP Snooping.................................................................... 25  
3.2.7.1 IGMP Configuration ................................................ 25  
3.2.8 Mirroring ............................................................................. 26  
3.2.8.1 Mirroring Configuration .......................................... 26  
3.2.9 Quality of Service (QoS)....................................................... 27  
3.2.9.1 QoS Configuration .................................................. 27  
3.2.9.2 QoS Mode: QoS Disabled........................................ 28  
3.2.9.3 QoS Mode: 802.1p.................................................. 28  
3.2.9.4 QoS Mode: DSCP.................................................... 30  
3.2.10 Storm Control ...................................................................... 31  
3.2.10.1Storm Control Configuration................................... 31  
3.3 Monitoring  
............................................................................. 32  
3.3.1 Statistics Overview............................................................... 32  
3.3.2 Detailed Statistics................................................................. 32  
3.3.3 LACP Status ......................................................................... 33  
LGB616A  
Page 6  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
3.3.3.1 LACP Aggregation Overview................................... 33  
3.3.3.2 LACP Port Status ..................................................... 34  
3.3.4 RSTP Status.......................................................................... 34  
3.3.4.1 RSTP VLAN Bridge Overview................................... 34  
3.3.4.2 RSTP Port Status...................................................... 35  
3.3.5 IGMP Status......................................................................... 36  
3.3.6 VeriPHY ............................................................................. 36  
3.3.6.1 VeriPHY Cable Diagnostics...................................... 36  
3.3.7 Ping  
............................................................................. 38  
3.3.7.1 Ping Parameters....................................................... 38  
4. Maintenance  
..............................................................................41  
4.1 Warm Restart ..............................................................................41  
4.2 Factory Default ..............................................................................41  
4.3 Software Upload .............................................................................41  
4.4 Configuration File Transfer.............................................................. 42  
4.5 Logout  
............................................................................. 42  
4.6 Reset Button for the Factory Default Setting.................................. 43  
LGB616A  
Page 7  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Overview  
1. Specifications  
Buffer Memory — 340 KB  
Compliance — FCC Class B; power supply is UL® listed  
Filtering/Forwarding Rate — 1000-Mbps port: 1,488,000 pps;  
100-Mbps port: 148,800 pps;  
10-Mbps port: 14,880 pps  
Jumbo Frames — 9.6 KB  
MAC Address — 8K  
Standards — IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, IEEE 802.3ab  
1000BASE-T, IEEE 802.3x flow control  
Transmission Media — 10BASE-T CAT3, 4, 5 UTP/STP;  
100BASE-TX CAT5 UTP/STP;  
1000BASE-T CAT 5E UTP/STP  
Connectors — (16) RJ-45, (1) power connector  
Indicators — (33) LEDs: Per port: (1) LINK/ACT, (1) 1000M;  
Per unit: (1) Power  
Power — Internal power supply: Input Voltage: 90–260 VAC, 50-60 Hz;  
Input Power/Watts: 20 watts (max.)  
Temperature Tolerance — Operating: +32 to +131° F (0 to +55° C);  
Storage: -4 to +194° F (-20 to +90° C)  
Operating Humidity — 10 to 90% relative humidity (non-condensing)  
Size — 1.73"H x 17.32"W x 8.66 D (4.4 x 45 x 22 cm)  
Weight — 6.39 lb. (2.9 kg) unit;  
6.61 lb. (3 kg) shipping  
LGB616A  
Page 8  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Overview  
2. Overview  
2.1 Introduction  
The 16-Port Web Smart Gigabit Ethernet Switch provides 16 10-/100-/1000-Mbps  
ports. It is designed for easy installation and enables high performance in an  
environment where traffic on the network and the number of users increase  
continuously. With the newest Gigabit chipset, this 19" Gigabit Ethernet switch  
fully supports the highest speed without any problems, even when running  
full-duplex fully loaded.  
The switch also provides automatic crossover detection on each port, making it  
easy to uplink to another switch without using a crossover cable.  
This rackmountable switch is specifically designed for medium to large  
workgroups. It provides smooth network migration and makes it easy to increase  
network capacity.  
2.2 Features  
• Supports real-time status (link, speed, duplex) of each port.  
• Supports port setting for enable or disable operation (the first port can’t be  
disabled).  
• Includes port setting for N-Way or force mode operation.  
• Features Broadcast Storm Protection.  
• Enables Port-basesd VLAN.  
• Supports priority queues for QoS.  
• Complies with IEEE 802.3 Ethernet, IEEE 802.3u Fast Ethernet, and IEEE 802.3ab  
Gigabit Ethernet standards.  
• 16 ports autonegotiate speeds of 10, 100, and 1000 Mbps.  
• 19" rackmountable.  
• Provides non-blocking and non-head of line blocking full wire-speed  
forwarding.  
• Store-and-forward operation support.  
• Supports 9.6 KB jumbo frames.  
• Provides 8K MAC addresses.  
• Supports broadcast storm filitering.  
LGB616A  
Page 9  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Overview  
• All ports provide autonegotiation and Auto MDI/MDI-X functions.  
• Supports flow control: Backpressure for half-duplex and IEEE 802.3x for  
full-duplex mode.  
• Smart plug and play.  
2.3 What’s Included  
Your package should contain the following items. If anything is missing  
or damaged, contact Black Box Technical Support at 724-746-5500  
• (1) 16-Port Web Smart Gigabit Ethernet Switch  
• (1) U.S. power cord  
• This user’s manual in PDF format on CD-ROM  
• (1) rackmount kit: (2) brackets, (8) screws  
2.4 Hardware Description  
Figures 2-1 and 2-2 show the front and back panels of the 16-Port Web Smart  
Gigabit Ethernet Switch. Table 2-1 describes its components.  
LGB616A  
Page 10  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Overview  
4
1
2, 3  
4
Figure 2-1. Front panel.  
5
6
7
Figure 2-2. Back panel.  
Table 2-1. 16-Port Web Smart Gigabit Ethernet Switch components.  
Number  
Component  
Description  
1
(1) Power LED  
Lights when power to the unit is on.  
2
3
(16) 1000M LEDs  
Light when a port is operating at 1000 Mbps.  
Light solid when link is up, blink when data is present, and are off  
when there is no link.  
(16) LINK/ACT LEDs  
4
5
6
(16) RJ-45 connectors Connect to 10/100/1000 devices.  
Air vents  
Maintain proper airflow.  
Power on/off switch  
Switches the power to the unit on or off.  
Links 90–260-VAC, 50-60-Hz, 20-W internal power supply to  
power outlet  
7
Power receptacle  
LGB616A  
Page 11  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3. Software Description  
This section explains how to set up and manage the switch through the Web user  
interface.  
3.1 Login  
First, open the Web browser, and go to 192.168.2.1. The login screen will appear.  
Type in the password (default: admin) to pass the authentication, and click on the  
Apply button. The following message will appear:  
“Password successfully entered.”  
Figure 3-1.  
LGB616A  
Page 12  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3.2 Configuration  
3.2.1 System  
This page shows system configuration information, as illustrated in Figure 3-3.  
Figure 3-2. System Configuration screen.  
LGB616A  
Page 13  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
• MAC Address: Displays the unique hardware address assigned by manufacturer  
(default).  
• S/W Version: Displays the switch’s firmware version.  
• H/W Version: Displays the switch’s hardware version.  
• DHCP Enabled: Click the box to enable DHCP.  
• Fallback IP address: Manually assign the IP address that the network is using.  
The default IP is 192.168.2.1.  
• Fallback Subnet Mask: Assign the subnet mask to the IP address.  
• Fallback Gateway: Assign the network gateway for industrial switch. The default  
gateway is 0.0.0.0.  
• Management VLAN: ID of a configured VLAN (1–4096) through which you can  
manage the switch. By default, all ports on the switch are members of VLAN 1.  
However, you change the management VLAN, the management station must  
be attached to a port belonging to this VLAN.  
• Name: Type in the new user name (the default value is ”admin”).  
• Password: Type in the new password (the default value is “admin”).  
• SNMP Enabled: Enables or disables SNMP on the switch. Supports SNMP version  
1 and 2c management clients.  
• SNMP Trap Destination: IP address of the trap manager to receive notification  
messages from this switch. Traps indicating status changes are issued by the  
switch to specified trap managers. You must specify trap managers so that key  
events are reported by this switch to your management station.  
• SNMP Read Community: A community string that acts like a password and  
permits access to the SNMP database on this switch. Authorized management  
stations are only able to retrieve MIB objects.  
• SNMP Trap Community: Community string sent with the notification operation.  
LGB616A  
Page 14  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3.2.2 Ports  
Port Security ensures access to a switch port based on MAC address, limits the  
total number of devices from using a switch port, and protects against MAC  
flooding attacks.  
3.2.2.1 Port Configuration  
In Port Configuration, you can set and view the operation mode for each port.  
• Enable Jumbo Frames: This switch provides more efficient throughput for large  
sequential data transfers by supporting jumbo frames on Gigabit Ethernet ports  
up to 9.6 KB. Compared to standard Ethernet frames that run only up to 1.5 KB,  
using jumbo frames significantly reduces the per-packet overhead required to  
process protocol encapsulation fields.  
• Power Saving Mode: Adjusts the power provided to ports based on the length  
of the cable used to connect to other devices. Only sufficient power is used to  
maintain connection requirements.  
• Mode: Manually set the port speed such as auto, 10 half, 10 full, 100 half,  
100 full, 1000 full. or disabled. Click on the Apply” button to complete the  
configuration.  
Flow Control  
Click the check box (x) to enable flow control. If flow control is set to enable, both  
parties can send PAUSE frames to the transmitting device(s) if the receiving port is  
too busy to handle the amount of data being sent. When it is set to disable, there  
will be no flow control on that port. The port will drop packets if the amount of  
data becomes too much for the port to handle.  
LGB616A  
Page 15  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-3.  
Figure 3-4.  
LGB616A  
Page 16  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3.2.3 VLAN  
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast  
domain, which would allow you to isolate network traffic, so only the members of  
the same VLAN will receive traffic from the members of the same VLAN.  
Basically, creating a VLAN from a switch is logically equivalent to reconnecting a  
group of network devices to another Layer 2 switch. However, all the network  
devices are still plugged into the same switch physically.  
3.2.3.1 Port Segmentation (VLAN) Configuration  
• VLAN ID: ID of the configured VLAN (1–4096, no leading zeroes).  
• VLAN Configuration List: Lists all the current VLAN groups created for this  
system. Up to 16 VLAN groups can be defined. VLAN 1 is the default untagged  
VLAN.  
Figure 3-5.  
3.2.3.2 VLAN Setup  
The switch supports up to 16 VLANs based on 802.1Q standard. From the VLAN  
Membership page you can create and delete VLANs, and change the VLAN port  
membership.  
LGB616A  
Page 17  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-6.  
3.2.3.3 VLAN Per Port Configuration  
The 802.1Q Per Port Configuration page allows you to change the VLAN  
parameters for individual ports or trunks. You can configure VLAN behavior for  
specific interfaces, including the accepted frame types and default VLAN identifier  
(PVID). Each row of the table corresponds to one port or trunk; trunked ports  
cannot be configured individually; configure the trunk instead.  
Figure 3-7. VLAN per port configuration.  
LGB616A  
Page 18  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
• Port/Trunk: The port number of the port or the ID of a trunk.  
• VLAN Aware Enabled: VLAN aware ports are able to use VLAN tagged frames  
to determine the destination VLAN of a frame. (Default: Enabled)  
• VLAN aware ports will strip the VLAN tag from received frames and insert the  
tag in transmitted frames (except for the PVID). VLAN unaware ports will not  
strip the tag from received frames or insert the tag in transmitted frames.  
• Ingress Filtering Enabled: If enabled, incoming frames for VLANs that do not  
include this ingress port in their member set will be discarded.  
(Default: Disabled)  
• Packet Type: Sets the interface to accept all frame types, including tagged or  
untagged frames, or only tagged frames. (Default: All) If the Packet Type is set  
to “All,” the port can accept incoming tagged and untagged packets. Any  
received packets that are untagged are assigned to the default VLAN. Any  
tagged packets will be dropped unless the port is a member of the VLAN identi-  
fied by the VLAN tag in the packet. If the Packet Type is set to “Tagged Only,”  
the port will drop untagged packets and will only receive tagged packets.  
Tagged packets will be dropped unless the port is a member of the VLAN iden-  
tified by the VLAN tag in the packet. Switches should be connected to each  
other with the Packet Type set to “Tagged Only.”  
• PVID: The PVID (Port VLAN ID) is associated with untagged, ingress packets. It is  
assigned to untagged frames received on the specified interface. The PVID has  
no effect on ports that have Packet Type set to “Tagged Only.” (Default PVID: 1)  
It is not possible to remove a port from VLAN 1 unless its PVID has been  
changed to something other than 1. Outgoing packets are tagged unless the  
packet’s VLAN ID is the same as the PVID. When the PVID is set to “None,” all  
outgoing packets are tagged.  
NOTE: If you select “Tagged Only” mode for a port, we recommend setting the  
PVID to “None” as the standard configuration.  
LGB616A  
Page 19  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3.2.4 Aggregation  
Port trunk allows multiple links to be bundled together and act as a single physical  
link for increased throughput. It provides load balancing, and redundancy of links  
in a switched inter-network. Actually, the link does not have an inherent total  
bandwidth equal to the sum of its component physical links. Traffic in a trunk is  
distributed across an individual link within the trunk in a deterministic method that  
called a hash algorithm. The hash algorithm automatically applies load balancing  
to the ports in the trunk. A port failure within the trunk group causes the  
network traffic to be directed to the remaining ports. Load balancing is  
maintained whenever a link in a trunk is lost or returned to service.  
3.2.4.1 Aggregation / Trunking Configuration  
To assign a port to a trunk, click the required trunk number, and then click  
Apply.”  
Figure 3-8. Aggregation/trunking configuration screen.  
3.2.5 LACP  
IEEE 802.3ad Link Aggregation Control Protocol (LACP) increases bandwidth by  
automatically aggregating several physical links together as a logical trunk and  
providing load balancing and fault tolerance for uplink connections.  
3.2.5.1 LACP Port Configuration  
• Port: The port number.  
• Enabled: Enables LACP on the associated port.  
LGB616A  
Page 20  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
• Key Value: Configures a port's LACP administration key. The port administrative  
key must be set to the same value for ports that belong to the same link  
aggregation group (LAG). If this administrative key is not set when an LAG is  
formed (i.e., it has the null value of 0), this key will automatically be set to the  
same value as that used by the LAG.  
Figure 3-9. LACP port configuration screen.  
3.2.6 RSTP  
IEEE 802.1w Rapid Spanning tree protocol (LACP) provides a loop-free network  
and redundant links to the core network with rapid convergence to ensure faster  
recovery from failed links, enhancing overall network stability and reliability.  
3.2.6.1 RSTP System Configuration  
• System Priority: This parameter configures the spanning tree priority globally for  
this switch. The device with the highest priority becomes the STP root device.  
However, if all devices have the same priority, the device with the lowest MAC  
address will then become the root device.  
• Hello Time: Interval (in seconds) at which the root device transmits a  
configuration message (BPDU frame). Number between 1–10 (default is 2).  
• Max Age: The maximum time (in seconds) a device can wait without receiving a  
configuration message before attempting to reconfigure. This also means the  
maximum life time for a BPDU frame. Number between 6–40 (default is 20).  
LGB616A  
Page 21  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
• Forward Delay: The maximum time (in seconds) the root device will wait before  
changing states (i.e., discarding to learning to forwarding). Number between  
4–30 (default is 15).  
• Force Version: Set and show the RSTP protocol to use. Normal - use RSTP,  
Compatible—compatible with STP.  
Figure 3-10. RSTP system configuration.  
3.2.6.2 RSTP Port Configuration  
• Port: The port ID. It cannot be changed. Aggregations mean any configured  
trunk group.  
• Enabled: Click on the tick-box to enable/disable the RSTP protocol for the port.  
• Edge: Expect the port to be an edge port (linking to an end station) or a link to  
another STP device.  
• Path Cost: This parameter is used by the STP to determine the best path  
between devices. Therefore, lower values should be assigned to ports attached  
to faster media, and higher values assigned to ports with slower media. Set the  
RSTP pathcost on the port. Number between 0–200000000. 0 means auto  
generated pathcost.  
LGB616A  
Page 22  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-11. RSTP port configuration screen.  
LGB616A  
Page 23  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-12. RSTP system configuration screen.  
Figure 3-13. RSTP system configuration screen.  
LGB616A  
Page 24  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3.2.7 IGMP Snooping  
IGMP Snooping is the process of listening to IGMP network traffic. IGMP  
Snooping, as implied by the name, is a feature that allows a layer 2 switch to  
“listen in” on the IGMP conversation between hosts and routers by processing the  
layer 3 IGMP packets sent in a multicast network.  
When IGMP Snooping is enabled in a switch, it analyzes all IGMP packets  
between hosts connected to the switch and multicast routers in the network.  
When a switch hears an IGMP report from a host for a given multicast group, the  
switch adds the host’s port number to the multicast list for that group. And,  
when the switch hears an IGMP Leave, it removes the host’s port from the table  
entry.  
Prevents flooding of IP multicast traffic, and limits bandwidth intensive video  
traffic to only the subscribers.  
3.2.7.1 IGMP Configuration  
• IGMP Enabled: When enabled, the switch will monitor network traffic to  
determine which hosts want to receive multicast traffic.  
d  
d  
Figure 3-14.  
LGB616A  
Page 25  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3.2.8 Mirroring  
Port Mirroring is used on a network switch to send a copy of network packets  
seen on one switch port (or an entire VLAN) to a network monitoring connection  
on another switch port. This is commonly used for network appliances that  
require monitoring of network traffic, such as an intrusion-detection system.  
3.2.8.1 Mirroring Configuration  
• Port to Mirror to: The port that will “duplicate” or “mirror” the traffic on the  
source port. Only incoming packets can be mirrored. Packets will be dropped  
when the available egress bandwidth is less than ingress bandwidth.  
• Ports to Mirror: Select the ports that you want to mirror from this section of the  
page. A port will be mirrored when the “Mirroring Enabled” check-box is  
checked.  
Figure 3-15. Mirroring configuration screen.  
LGB616A  
Page 26  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-16. Mirroring configuration screen.  
3.2.9 Quality of Service (QoS)  
In QoS Mode, select QoS Disabled, 802.1p, or DSCP to configure the related  
parameters.  
3.2.9.1 QoS Configuration  
• Strict: Services the egress queues in sequential order, transmitting all traffic in  
the higher priority queues before servicing lower priority queues.  
• WRR: Weighted Round-Robin shares bandwidth at the egress ports by using  
scheduling weights with default values of 1, 2, 4, 8 for queues 0 through 7,  
respectively. (This is the default selection.)  
NOTE: WRR can only be selected if Jumbo Frame mode is disabled on the Port  
Configuration page.  
LGB616A  
Page 27  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-17. QoS configuration screen.  
3.2.9.2 QoS Mode: QoS Disabled  
When the QoS Mode is set to QoS Disabled, the following table is displayed.  
Figure 3-18. QoS disabled screen.  
3.2.9.3 QoS Mode: 802.1p  
Packets are prioritized using the 802.1p field in the VLAN tag. This field is three  
bits long, representing the values 0–7. When the QoS Mode is set to 802.1p, the  
802.1p Configuration table appears, allowing you to map each of the eight 802.1p  
values to a local priority queue (low, normal, medium or high). The default set-  
tings are shown below.  
When the QoS Mode is set to 802.1p, the 802.1p Configuration table is displayed  
as shown next.  
LGB616A  
Page 28  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-19. QoS configuration custom selected.  
Figure 3-20.  
LGB616A  
Page 29  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3.2.9.4 QoS Mode: DSCP  
DSCP: Packets are prioritized using the DSCP (Differentiated Services Code Point)  
value. The Differentiated Services Code Point (DSCP) is a six-bit field that is  
contained within an IP (TCP or UDP) header. The six bits allow the DSCP field to  
take any value in the range 0–63. When QoS Mode is set to DSCP, the DSCP  
Configuration table is displayed, allowing you to map each of the DSCP values to  
a hardware output queue (low, normal, medium or high). The default settings  
map all DSCP values to the high priority egress queue. Users can use the Prioritize  
Traffic drop-down list to quickly set the values in the DSCP Configuration table to  
a common priority queue. Use Custom if you want to set each value individually.  
When the QoS Mode is set to DSCP, the DSCP Configuration table is displayed as  
shown below.  
Figure 3-21.  
LGB616A  
Page 30  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-22.  
3.2.10 Storm Control  
Broadcast storms may occur when a device on your network is malfunctioning, or  
if application programs are not well designed or properly configured. If there is  
too much broadcast traffic on your network, performance can be severely  
degraded or everything can come to complete halt.  
You can protect your network from broadcast storms by setting a threshold for  
broadcast traffic for each port. Any broadcast packets exceeding the specified  
threshold will then be dropped.  
3.2.10.1 Storm Control Configuration  
There are three type of traffic that can be rate limited, including broadcast  
multicast frame and Flooded Uncast Rate.  
Figure 3-23.  
• Enable Rate Limit: Click the check box to enable storm control.  
LGB616A  
Page 31  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
• Rate (number of frames per second): The Rate field is set by a single drop-down  
list. The same threshold is applied to every port on the switch. When the  
threshold is exceeded, packets are dropped, irrespective of the flow-control  
settings.  
• Web: Click PORTS, Storm Control. This page enables you to set the broadcast  
storm control parameters for every port on the switch.  
3.3 Monitoring  
3.3.1 Statistic Overview  
Statistic Overview for all ports  
User can mirror traffic from any source port to a target port for real-time analysis  
the following figures shows clearly the statistics overview.  
Figure 3-24.  
3.3.2 Detailed Statics  
Figure 3-25.  
LGB616A  
Page 32  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3.3.3 LACP Status  
3.3.3.1 LACP Aggregation Overview  
Figure 3-26.  
• Port: The port number.  
• Port Active: Shows if the port is a member of an active LACP group.  
• Partner Port Number: A list of the ports attached at the remote end of this LAG  
link member.  
• Operational Port Key: Current operational value of the key used by this LAG.  
LGB616A  
Page 33  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
3.3.3.2 LACP Port Status  
Figure 3-27. LACP port status screen.  
3.3.4 RSTP Status  
3.3.4.1 RSTP VLAN Bridge Overview  
Figure 3-28. RSTP VLAN bridge overview.  
• Hello Time: Interval (in seconds) at which the root device transmits a  
configuration message.  
• Max Age: The maximum time (in seconds) a device can wait without receiving a  
configuration message before attempting to reconfigure. All device ports (except  
for designated ports) should receive configuration messages at regular intervals.  
Any port that age out STA information (provided in the last configuration  
message) becomes the designated port for the attached LAN. If it is a root port,  
a new root port is selected from among the device ports attached to the  
network.  
LGB616A  
Page 34  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
• Fwd Delay: The maximum time (in seconds) the root device will wait before  
changing states (i.e., discarding to learning to forwarding). This delay is required  
because every device must receive information about topology changes before  
it starts to forward frames. In addition, each port needs time to listen for  
conflicting information that would make it return to a discarding state;  
otherwise, temporary data loops might result.  
• Topology: Indicates if spanning tree topology is steady or undergoing  
reconfiguration. (The time required for reconfiguration is extremely short,  
so no values other than “steady” state are likely to be seen in this field.)  
• Root ID: The priority and MAC address of the device in the Spanning Tree that  
this switch has accepted as the root device, and the port connected to the root  
device.  
3.3.4.2 RSTP Port Status  
Figure 3-29. RSTP port status screen.  
• Port/Group: The number of a port or the ID of a static trunk.  
• Path Cost: The cost for a packet to travel from this port to the root in the  
current Spanning Tree configuration. The slower the media, the higher the cost.  
• Edge Port: Shows if this port is functioning as an edge port, either through  
manual selection (see the RSTP Port Configuration table) or auto-detection.  
NOTE: If the switch detects another bridge connected to this port, the manual  
setting for Edge Port will be overridden, and the port will instead function  
as a point-to-point connection.  
LGB616A  
Page 35  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
• P2P Port: Shows if this port is functioning as a Point-to-Point connection to  
exactly one other bridge. The switch can automatically determine if the interface  
is attached to a point-to-point link or to shared media. If shared media is  
detected, the switch will assume that it is connected to two or more the switch  
will assume that it is connected to two or more bridges.  
• Protocol: Shows the spanning tree protocol functioning on this port, either STP  
or STP (that is, STP-compatible mode).  
3.3.5 IGMP Status  
IGMP Status shows the IGMP Snooping statistics for the entire switch.  
• VLAN ID: VLAN ID number.  
• Querier: Show whether Querying is enabled.  
• Queries transmitted: Show the number of transmitted Query packets.  
• Queries received: Show the number of received Query packets.  
• v1 Reports: Show the number of received v1 Report packets.  
• v2 Reports: Show the number of received v2 Report packets.  
• v3 Reports: Show the number of received v2 Report packets.  
• v3 Leave: Show the number of v3 leave packets received.  
Figure 3-30. IGMP status screen.  
3.3.6 VeriPHY  
3.3.6.1 VeriPHY Cable Diagnostics  
Users can perform cable diagnostics for all ports or selected ports to diagnose any  
cable faults (short, open, etc..) and feedback a distance to the fault.  
• Cable Diagnostics: Cable diagnostics is performed on a per-port basis. Select the  
port number from the drop-down list.  
LGB616A  
Page 36  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
• Cable Status: Shows the cable length, operating conditions and isolates a variety  
of common faults that can occur on Category 5 twisted pair cabling.  
Figure 3-31.  
Figure 3-32.  
LGB616A  
Page 37  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-33.  
Figure 3-34.  
3.3.7 Ping  
This command sends ICMP echo request packets to another node on the  
network.  
3.3.7.1 Ping Parameters  
• Target IP Address: IP address of the host.  
LGB616A  
Page 38  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
• Count: Number of packets to send. (Range: 1–20)  
• Time Out: setting the time period the host will Ping.  
Use the ping command to see if another site on the network can be reached.  
The following are some results of the ping command:  
• Normal response: The normal response occurs in one to ten seconds, depending  
on network traffic.  
• Destination does not respond: If the host does not respond, a “timeout”  
appears in ten seconds.  
• Destination unreachable: The gateway for this destination indicates that the  
destination is unreachable.  
• Network or host unreachable: The gateway found no corresponding entry in the  
route table.  
Press <Esc> to stop pinging.  
'
Figure 3-35.  
LGB616A  
Page 39  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Software Description  
Figure 3-36.  
Figure 3-37.  
LGB616A  
Page 40  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Maintenance  
4. Maintenance  
4.1 Warm Restart  
Press the “Yes” button to restart the switch. The reset will be complete when the  
power lights stop blinking.  
Figure 4-1. Warm Reset screen.  
4.2 Factory Default  
This function forces the switch back to the original factory settings. To reset the  
switch, select “Reset to Factory Defaults” from the drop-down list and click  
Apply.” The LAN IP Address, Subnet Mask and Gateway IP Address will be reset  
to their factory default settings.  
Figure 4-2. Factory Default screen.  
4.3 Software upload  
Select “Upgrade Firmware” from the Tools drop-down list then click on the  
“Browse” button to select the firmware file. Click the APPLY button to upgrade  
the selected switch firmware file. User can download firmware files for user’s  
LGB616A  
Page 41  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Maintenance  
Figure 4-3.  
4.4 Configuration File Transfer  
Configuration file transfer allows you to save the switch’s current configuration  
or restore a previously saved configuration back to the device. Configuration files  
can be saved to any location on the web management station. “Upload” the  
configuration file to save a configuration or “Download” to restore a  
configuration. Use the “Browse” button to choose a file location on the Web  
management station, or to find a saved configuration file.  
Figure 4-4.  
4.5 Logout  
The administrator has write access for all parameters governing the onboard  
agent. The user should assign a new administrator password as soon as possible,  
and store it in a safe place.  
LGB616A  
Page 42  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Maintenance  
4.6 Reset Button for the Factory Default Setting  
Follow these steps to reset the Web Smart Switch back to the original default:  
STEP 1: Turn on the Web Smart Switch  
STEP 2: Press and hold the reset button continuously for 5 seconds and release  
the reset button.  
STEP 3: The switch will reboot for 20 seconds and the switch configuration will  
revert back to the default setting.  
LGB616A  
Page 43  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Black Box Tech Support: FREE! Live. 24/7.  
Tech support the  
way it should be.  
Great tech support is just 60 seconds away at  
724-746-5500 or blackbox.com.  
About Black Box  
Black Box provides an extensive range of networking and infrastructure products.  
You’ll find everything from cabinets and racks and power and surge protection  
products to media converters and Ethernet switches all supported by free, live 24/7  
Tech support available in 60 seconds or less.  
© Copyright 2014. Black Box Corporation. All rights reserved.  
LGB616A, version 2  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Septic System ST4125D User Manual
Black Box Switch KV120A User Manual
Bogen Car Speaker VRS1 User Manual
Bravetti Fryer F2000 User Manual
Breville Oven BPZ600XL User Manual
Brinkmann Gas Grill 4905 User Manual
Brinkmann Smoker 140 7085 K User Manual
Brother All in One Printer DCP 7020 User Manual
Canon Network Router MF8080CW User Manual
Cerwin Vega Speaker CMX210 User Manual