Bionaire Humidifier BCM7255 CN User Manual

BCM7255CN06EFM3.qxd  
8/24/06 09:44 Page 1  
can be damaged by moisture or water. Place on a  
moisture-resistant surface.  
13.DO NOT allow the Moisture Outlet to directly face the  
wall. Moisture could cause damage, particularly to wall  
paper.  
DIGITAL HUMIDISTAT INSTRUCTIONS  
HUMIDIFIER SAFETY  
PLEASE SAVE THESE  
INSTRUCTIONS  
To take advantage of the Digital Electronic Humidistat,  
press the mode  
button until the speed is set in either  
PLEASE READ AND SAVE  
THESE IMPORTANT SAFETY  
FILLING THE WATER TANK  
14.Humidifier should be unplugged when not in use.  
the HIGH (II) or LOW (I) setting, and the desired Humidity  
is set. When the humidity level rises above the set  
humidity, the humidifier will stop. When the humidity level  
drops below the set humidity, the humidifier will turn on  
automatically.  
CONSUMER SAFETY INFORMATION  
1. Remove the tank from the base of the humidifier and  
bring to the faucet. Turn the tank upside down and  
twist off the tank cap by turning counter clockwise. Fill  
tank with cool, fresh tap water. DO NOT fill with warm  
water as this may cause leaking. Replace the cap on  
tank FIRMLY.  
2. When full, carry tank to the humidifier and place onto  
the base. The tank holds 3/4 gallon of water and the  
base holds 1/4 gallon of water. The tank will  
immediately begin to empty into base.  
15.NEVER tilt, move, or attempt to empty unit while it is  
operating. Shut off and unplug before removing the  
water tank and moving the unit. If you have a warm  
mist humidifier, DO NOT attempt to remove the water  
tank within 15 minutes after the humidifier is turned off  
and unplugged. Serious injury may result.  
Digital COOL MIST  
NOTE: This is an electrical appliance and requires  
attention when in use.  
NOTE: If moisture forms on the walls or windows of the  
room, turn off the humidifier. The room already has plenty  
of humidity and additional moisture may cause damage.  
INSTRUCTIONS  
Humidifier  
IMPORTANT SAFEGUARDS  
NOTE: When the Digital Electronic Humidistat is set, either  
the HIGH (II) or LOW (I) power light and the percent  
humidity light will remain lit during operation. (See Figure 2)  
MODEL BCM7255-CN  
When using electrical appliances, basic safety precautions  
should always be followed to reduce the risk of fire, electric  
shock, and injury to persons, including the following:  
1. Read all instructions before using the appliance.  
2. To avoid fire or shock hazard, plug the appliance  
directly into a 120V AC electrical outlet.  
3. Keep the cord out of heavy traffic areas. To avoid fire  
hazard, NEVER put the cord under rugs or near heat  
registers.  
4. DO NOT place humidifier near heat sources such as  
stoves, radiators, and heaters. DO locate your  
humidifier on an inside wall near an electrical outlet.  
The humidifier should be at least 4” away from the wall  
for best results.  
5. NEVER place humidifier in an area where it is accessible  
to children. NEVER use humidifier in a closed room,  
particularly where a child may be sleeping, resting, or  
playing (a closed room may result in excessive humidity).  
6. WARNING: Do not attempt to refill humidifier without first  
unplugging the unit from its electrical outlet. Failure to  
heed this warning may cause personal injury. Be sure to  
unplug the unit by pulling on the plug and not the cord.  
7. Never place anything over moisture outlet when the  
unit is running.  
8. NEVER drop or insert any object into any openings.  
DO NOT place hands, face or body directly over or  
near Moisture Outlet while unit is in operation. DO NOT  
cover Moisture Outlet while the unit is operating.  
9. DO NOT operate any appliance with a damaged cord  
or plug, after the appliance malfunctions, or if it has  
been dropped or damaged in any manner. Return  
appliance to manufacturer for examination, electrical or  
mechanical adjustment, or repair.  
10.Use appliance only for intended household use as  
described in this manual. Any other use not  
recommended by the manufacturer may cause fire,  
electric shock, or injury to persons. The use of  
attachments not recommended or sold the  
manufacturer may cause hazards.  
16.This humidifier requires daily and weekly maintenance to  
operate appropriately. Refer to daily and weekly cleaning  
procedures. Use only cleaners and additives  
NOTE: DO NOT block air inlet or outlet.  
THIS PRODUCT IS EQUIPPED  
WITH A POLARIZED PLUG (a  
Figure 2  
recommended by the manufacturer. Never use gasoline,  
glass cleaner,furniture polish, paint thinner, or other  
household solvents to clean any part of the humidifier.  
3. Plug the power cord into a 120V AC electrical outlet.  
B
plug having one blade wider than  
the other). This plug will fit into the  
A
Filter Monitor  
17.Excessive humidity in a room can cause water  
condensation on windows and some furniture. If this  
happens, turn the humidifier OFF.  
18.Do not use humidifier in an area where humidity level is  
in excess of 50%. Use a hygrometer, available at your  
local retailer or through the manufacturer to measure  
the humidity.  
19.DO NOT attempt to repair or adjust any electrical or  
mechanical functions on this unit. Doing so will void your  
warranty. The inside of the unit contains no user  
serviceable parts. All servicing should be performed by  
qualified personnel only.  
20.Never place housing under water flow, or immerse in  
liquids.  
21.DO NOT plug in the cord with wet hands, electric shock  
could result.  
22.DO NOT pour water in any openings other than the  
water tank.  
23.If you have a warm mist humidifier, allow unit to cool  
before refilling water tank or maintenance as the heater  
bulb is hot.  
24.To prevent damage to surfaces, do not place humidifier  
under overhanging surfaces.  
C
Figure 1  
Control Panel  
power outlet only one way. If the  
Reservoir Handle  
plug does not fit fully into the  
A. LEFT LEDS  
B
outlet, reverse the plug. If it still does  
B. RIGHT LEDS  
Housing  
D
not fit, contact qualified personnel to install the proper outlet.  
C. mode  
BUTTON  
D. RC SENSOR LENS  
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS  
POLARIZED PLUG IN ANY WAY.  
NOTE: Allow up to 30 minutes for the filter to fully absorb  
water and for the unit to produce moisture.  
The length of cord used on this appliance was selected to  
reduce the hazards of becoming tangled in, or tripping over  
a longer cord. If a longer cord is necessary, an approved  
extension cord may be used. The electrical rating of the  
extension cord must be equal to or greater than the rating of  
the humidifier. Care must be taken to arrange the  
extension cord so that it will not drape over the countertop  
or tabletop where it can be pulled on by children or  
accidentally tripped over.  
NOTE: The Digital Humidifier has memory. This means  
that when you turn the unit back on, it will be at the last  
setting the humidifier was set at.  
If you do not plan to use the humidifier for two or more  
days, make sure any residual water is drained from the  
water tank, base and wick filter to prevent algae or  
bacteria growth.  
Water Reservoir  
Wick Holder  
OPERATING INSTRUCTIONS  
Your humidifier is equipped with a technologically advanced  
Digital Electronic Humidistat. You can set the humidifier to  
run continuously in manual mode or set the Digital Electronic  
Humidistat to your desired humidity setting. The Digital  
Electronic Humidistat will automatically turn the humidifier  
ON or OFF, depending on the preset comfort level. The  
comfort level ranges between 35% and 55% relative  
humidity.  
HOW COOL MIST WORKS  
REMOTE INSTRUCTIONS  
®
Your Bionaire Cool Mist humidifier draws dry air through  
1. Insert 2 AAA batteries into  
Figure 3  
the rear air intake grill area. This air is then passed through  
2 moisture–laden wick filters which retains the minerals and  
deposits. The resulting moist air is directed back into the  
room from the top air grill.  
back of remote control.  
2. Press the button on remote  
to begin operation.  
3. Use the remote to control  
the same features as the  
base unit.  
NOTE: Do not mix new and old  
batteries. Do not mix alkaline,  
standard (carbon-zinc), or rechargeable (nickel-cadmium)  
batteries.  
25.NEVER operate unit without water in the tank.  
26.Do not move unit after it has been used until unit cools  
completely.  
NOTE: This humidification system provides a cool, invisible  
moisture output. It is normal not to see the mist.  
NOTE: A humidity level below 20% can be unhealthy and  
uncomfortable. The recommended humidity level is between  
40%-50%.  
MANUAL MODE INSTRUCTIONS  
1. Plug the humidifier into a 120V AC electrical outlet.  
Filter#: BWF100P  
Read instructions before operating.  
Retain for future reference.  
27.Use both hands when carrying full tank of water.  
2. To start the unit, push the mode  
button once for the  
HIGH (II) manual setting. (See Figure 2)  
Instruction Leaflet  
3. Press the button again for the LOW (I) manual setting.  
BEFORE USE (PRE-OPERATING INSTRUCTIONS)  
(See Figure 2)  
1. Be sure the humidifier is switched to OFF and the unit  
INFO-LINE  
4. To stop the unit, press and hold the button for two  
seconds, or keep pressing the button until all the  
humidity indicators are OFF.  
NOTE: In Manual Mode, only the LOW (I) or HIGH (II)  
power light will be lit.  
11.DO NOT use outdoors.  
is disconnected from the electrical outlet.  
If after having read this leaflet, you have any  
questions or comments on your humidifier,  
call 1-800-253-2764 in North America.  
12.Always place humidifier on a firm, flat, level surface. A  
waterproof mat or pad is recommended for use under  
the humidifier. NEVER place it on a rug or carpet, or on  
a finished floor that may be damaged by exposure to  
water or moisture.  
2. Take housing off base and remove foam packing  
beneath the housing. Place housing back on base.  
3. Select a location for your humidifier, on a flat surface,  
about 4” away from the wall. DO NOT place the  
humidifier on a finished floor or near furniture, which  
9100030004242  
TM  
PERMAtech FILTER CLEANING INSTRUCTIONS  
DAILY MAINTENANCE  
STORAGE INSTRUCTIONS  
When not using your humidifier for an extended period of  
time:  
TWO (2) YEARS LIMITED WARRANTY  
SAVE THIS WARRANTY INFORMATION  
b) A dated sales receipt or PROOF OF PURCHASE,  
Frequently Asked Questions  
1. The water tray should be cleaned  
1. Before cleaning, push the Digital button for 2 seconds  
to turn the unit OFF and disconnect from the electrical  
outlet.  
2. Remove the housing and the tank from the humidifier  
and place in sink or tub.  
3. Carry the base of the unit to the sink, remove the wick  
holder and wicks, place in sink, drain any remaining  
water and rinse thoroughly to remove any sediment or  
dirt. Wipe clean, and dry with a clean cloth or paper  
towel. NOTE: the base and wick holder are dishwasher  
safe TOP RACK ONLY.  
4. Drain the water from the tank into the sink and rinse  
tank thoroughly. Wipe clean, and dry with a clean cloth  
or paper towel.  
c) Your $10.00 check for return shipping and  
handling, and  
Figure 4  
Question  
• What are the variables that  
affect run time?  
Answer  
when you clean the filter. The  
The estimated run time for this humidifier is based on  
average room conditions. The actual run time of your  
humidifier is dependent on numerous variables such as:  
A. This Warranty applies only to the original purchaser of  
this product.  
water tray is a convenient way to  
r
e
h
1. Do not leave filters in unit.  
s
F
t
a
d) The model number of the unit and the problem  
you are having. (Enclose in an envelope and tape  
directly to the unit before the box is sealed.)  
carry the filter to prevent dripping.  
l
W
2. Clean, rinse and thoroughly dry the humidifier as  
directed in weekly maintenance. DO NOT leave any  
water in the unit when storing. Leaving water in the  
unit may render the unit inoperable for the following  
season.  
3. Place the humidifier in the original carton and store in  
a cool, dry place.  
Air exchange in the room where the humidifier is placed.  
Room construction of the room where the humidifier is  
placed.  
Temperature of the room where the humidifier is placed.  
Humidity levels in the room where the humidifier is  
placed.  
Movement of occupants and the opening and closing of  
doors in the room where the humidifier is placed.  
Home furnishings in the room where the humidifier is  
placed.  
2. Mix 1 gallon warm tap water with  
1 teaspoon concentrated  
antibacterial liquid dish washing  
soap.  
3. Fully submerge filter in soap  
solution for 15-20 minutes.  
4. Dunk filter in soap solution several times then gently  
press to release the soapy water. Be sure not to wring,  
pull or scrub filter as this will degrade the filter.  
5. Run under cool tap water until there is no soap  
remaining. Some discoloration may still be visible, this is  
normal and does not affect performance.  
B. This Warranty applies ONLY to repair or replacement of  
any supplied or manufactured parts of this product that,  
upon inspection by JCS/THG, LLC authorized personnel,  
is shown to have failed in normal use due to defects in  
material or workmanship. JCS/THG, LLC will determine  
whether to repair or replace the unit. This Warranty  
does not apply to installation expenses.  
3. JCS/THG, LLC recommends you ship the package  
U.P.S. ground service for tracking purposes.  
4. All shipping charges must be prepaid by you.  
5. Mark the outside of your package:  
Bionaire  
4. Follow cleaning instructions before and after storing  
filters.  
• How do I remove film on  
water tank?  
See Daily Maintenance instructions. Regular cleaning is  
recommended.  
C. Operating this unit under conditions other than those  
recommended or at voltages other than the voltage  
indicated on the unit, or attempting to service or modify  
the unit, will render this WARRANTY VOID.  
JCS/THG, LLC  
• How can I extend the run  
time?  
Run your unit on the lowest setting.  
SERVICE INSTRUCTIONS  
If your unit has electronics, set it to your desired humidity  
level. The unit will turn on and off, which will extend the  
run time.  
5. Put filters back in wick holder, replace on base, replace  
the housing, then refill tank with cool tap water as  
instructed earlier in the Filling Instructions. Do not  
overfill.  
303 Nelson Avenue  
1. Do NOT attempt to repair or adjust any electrical or  
mechanical functions on this unit. Doing so will void the  
warranty. The inside of the unit contains no user  
serviceable parts. All servicing should be performed by  
qualified personnel only.  
2. If you need to exchange the unit, please return it in its  
original carton, with a sales receipt, to the store where  
you purchased it. If you are returning the unit more than  
30 days after the date of purchase, please see the  
enclosed warranty.  
Neosho, MO 64850  
SHIPPING AND HANDLING CHARGES: $10.00 (USD)  
Fill the tank all the way full, place it on the base, let the  
water empty into the base until it stops bubbling, then  
refill the tank full again. This ensures maximum water  
capacity and will extend run time.  
6. Gently shake or press the filter to remove excess water.  
D. Unless otherwise proscribed by law, JCS/THG,  
LLC shall not be liable for any personal injury,  
property or any incidental or consequential  
damage of any kind resulting from malfunctions,  
defects, misuse, improper installation or alteration  
of this product.  
7. The filter can be put directly into the humidifier while still  
damp if it is to be used right away, or allow filter to dry  
completely if humidifier is to be stored.  
Should your filter become damaged or lost, please call  
the customer service number listed in the manual for a  
replacement part. The part number for this filter is:  
BWF100P.  
6. Follow Operating Instructions.  
This Warranty gives you specific legal rights, and you may  
have other rights which vary from state to state. The  
provisions of this Warranty are in addition to, and not a  
modification of, or subtraction from, the statutory  
warranties and other rights and remedies contained in any  
applicable legislation. To the extent that any provision of  
this Warranty is inconsistent with any applicable law, such  
provision shall be deemed voided or amended, as  
necessary, to comply with such law.  
WEEKLY MAINTENANCE  
To Remove Scale:  
1. Repeat steps 1-4 above.  
Troubleshooting  
Solution  
Problem  
E. All parts of this product excluding filters, which are  
covered under separate warranty, are guaranteed for a  
period of 2 years as follows:  
Drain water from base and allow unit to dry for  
15 minutes.  
Check circuit breaker.  
• Unit does not turn on.  
2. Clean the base by partially filling the base with one  
8-oz cups of undiluted white vinegar, or by using  
3. Should your humidifier require service, please call  
TM  
1-800-253-2764 in North America for further assistance.  
CLEANING AND MAINTENANCE INSTRUCTIONS  
Clean-Away Solution (DMS216) by the manufacturer.  
Wait 15 minutes before starting humidifier.  
See Weekly Maintenance under Cleaning and  
Maintenance Instructions. Regular cleaning is  
recommended to keep the unit functioning properly.  
Raise the level of humidity by adjusting  
the humidistat (see Operating Instructions).  
Follow filter cleaning instructions in manual.  
• Mist output minimal to  
none.  
1. Within the first 30 days from date of purchase, the  
store from which you purchased your product  
should replace this product if it is defective in  
material or workmanship (provided the store has  
in-stock replacement.) If you intend to assert any  
claim in connection with the product, please follow  
the instructions in paragraph F.  
Leave this solution in the base for 20 minutes, while  
cleaning the all interior surfaces with a soft brush.  
Remove base scale by wiping the base with a cloth  
dampened with undiluted white vinegar.  
4. If you have any other questions or comments, feel free  
Humidifiers provide comfort by adding moisture to dry,  
heated indoor air. To benefit most from the humidifier  
and avoid product misuse, follow all instructions carefully.  
Please note that this is an electrical appliance and  
requires attention when in use.  
In addition, if you do not follow the recommended care  
and maintenance guidelines, micro-organisms may be  
able to grow in the water within the water tank. You must  
routinely follow the cleaning procedures that follow in  
order to ensure proper, efficient operation of your  
humidifier. Proper maintenance and cleaning is essential  
to the continued performance of your unit and the  
avoidance of algae or bacteria build-up.  
to write to us or visit our website www.bionaire.com  
Bionaire  
JCS/THG, LLC  
303 Nelson Avenue  
Neosho, MO 64850  
3. Rinse with clean warm water to remove the cleaning  
solution before disinfecting the tank.  
To Disinfect Humidifier Base and Tank:  
1. Fill humidifier base with 1/4 gallon of water and 1/2  
teaspoon of chlorine bleach.  
2. Fill the tank 1/2 full with water and 1/2 teaspoon of  
chlorine bleach.  
3. Let the solution stand for 20 minutes, swishing every  
few minutes. Wet all surfaces.  
4. Carefully empty the base and tank after 20 minutes,  
and rinse with water until you cannot detect any bleach  
smell. Dry with a clean cloth or paper towel.  
Remove tank cap then replace or reposition ring.  
Tighten the cap.  
• Water leaks from tank.  
• Filter turns brown.  
Follow filter cleaning instructions in manual.  
In areas with hard water the filter will need to be  
changed more frequently.  
2. Within the first 24 months from date of purchase,  
JCS/THG, LLC will repair or replace the product if it  
is defective in material or workmanship, subject to  
the conditions in paragraph G.  
See Daily Maintenance under Cleaning and  
Maintenance instructions. Regular cleaning is  
recommended to keep the unit functioning properly.  
• Film on water tank.  
TM  
To order Clean-Away Solution (DMS216),  
F. If you have any other problem or claim in connection  
with this product, please write to our Consumer Service  
Department.  
Follow filter cleaning instructions in manual.  
• Water in tanks appears  
cloudy.  
Use cool water to fill the water tank and only use  
®
Bionaire care products recommended in this manual.  
G. IMPORTANT RETURN INSTRUCTIONS. Your Warranty  
depends on your following these instructions if you are  
returning the unit to JCS/THG, LLC:  
Set the Digital Electronic Humidistat to a higher  
or lower desired setting.  
• Unit cycles on/off.  
• Very tight tank cap.  
TM  
5. Check the FilterClean to see if it is time to wash the  
filters.  
Add liquid soap to cap gasket to ease opening.  
1. Carefully pack the item in its original carton or other  
suitable box to avoid damage in shipping.  
6. Refill the water tank as directed with cool tap water,  
replace the humidifier housing, and turn the unit on.  
© 2006 JCS/THG, LLC  
®
TM  
TM  
TM  
Bionaire , the Bionaire logo , PERMAtech , FilterClean  
2. Before packing your unit for return, be sure to  
enclose:  
TM  
and Clean-Away are trademarks of JCS/THG, LLC.  
a) Your name, full address with zip code and  
telephone number  
BCM7255CN06EFM3  
Printed in China  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Beyonwiz TV Converter Box AP E1 User Manual
Black Decker Blender BX700G User Manual
Bolens Lawn Mower 840 thru 849 User Manual
Bosch Appliances Boiler 24I RSF User Manual
Breville Waffle Iron BSG520XL User Manual
Brother All in One Printer MFC9750 User Manual
Canon Scanner CR 55 User Manual
Casio Video Game Keyboard PX 5S User Manual
Chauvet DVD Player GBC 20 User Manual
Cisco Systems Conference Phone OL 7372 01 User Manual