Bionaire Dehumidifier BU5100 User Manual

BU5000_5100_5200-U_07EM2.qxd 7/23/07 13:49 Page 1  
ULTRASONIC humidifier  
BU5100  
BU5200  
BU5000  
© 2007 Sunbeam Products, Inc. doing business as  
Jarden Consumer Solutions. All Rights Reserved.  
Printed in China  
BU5000/BU5100/BU520007EM2  
9100030004739  
Instruction Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BU5000_5100_5200-U_07EM2.qxd 7/23/07 13:49 Page 5  
Tank Capacity  
(gallon)  
Runs Up To (hrs)  
PLEASE SAVE THESE  
INSTRUCTIONS  
Model  
BU5000  
BU5100  
BU5200  
1.2  
2.0  
0.6  
19  
36  
19  
CONSUMER SAFETY INFORMATION  
NOTE: This is an electrical appliance and requires attention  
when in use.  
NOTE: If moisture forms on the walls or windows of the  
room, turn off the humidifier. The room already has plenty  
of humidity and additional moisture may cause damage.  
5. Place tank back on to the base. The tank will  
immediately begin to empty into the base.  
NOTE: DO NOT block air inlet or outlet.  
6. Plug the humidifier into a 120V electrical outlet.  
CORD AND PLUG INSTALLATION SAFETY  
INSTRUCTIONS  
OPERATING INSTRUCTIONS  
1. To turn the humidifier on, switch the Slider Wheel (C) to  
produce the highest moisture level ( ). A lower setting  
will produce lower moisture level but with longer run  
time (for BU5000 and BU5100 only). The detailed  
settings for each model are shown as below:  
This appliance has a POLARIZED AC PLUG (one blade is  
wider than the other). To reduce the risk  
of electric shock, this plug is intended to  
fit in a polarized outlet only one way. If  
the plug does not fit fully in the outlet,  
reverse the plug. If it still does not fit,  
contact a qualified electrician to install  
the proper outlet.  
BU5000:  
BU5100:  
BU5200:  
Off ( ) - Low ( ) - High (  
)
O
Off (  
) - High (  
)
O
Off ( ) - On (  
)
O
2. When the humidifier runs out of water, the transducer  
will automatically shut off and the fan will keep running  
to dry any residual water out of the base and chamber.  
DO NOT ATTEMPT TO MODIFY THIS PLUG OR  
DEFEAT THIS SAFETY FEATURE IN ANY WAY.  
The length of cord used on this appliance was selected to  
reduce the hazards of becoming tangled in, or tripping  
over a longer cord. If a longer cord is necessary an  
approved extension cord may be used. The electrical  
rating of the extension cord must be equal to or greater  
than the rating of the humidifier. Care must be taken to  
arrange the extension cord so that it will not drape over the  
countertop or tabletop where it can be pulled on by  
children or accidentally tripped over.  
3. Once the tank is empty, turn the the Slider Wheel to the  
Off position ( ) and unplug the unit.  
O
4. Before refilling the tank, empty any residual water from  
the base and tank. Follow daily maintenance instructions.  
Figure 1  
BU5000  
BU5200  
BU5100  
E
A
PRE-OPERATING INSTRUCTIONS  
A
B
A
1. Be sure the humidifier is switched off (the Slider Wheel  
(C) is turned all the way towards " " position).  
O
F
2. Select a location for your humidifier, on a flat level  
surface about 4 inch away from the wall. DO NOT  
place the humidifier on a finished floor or near furniture,  
which can be damaged by too much moisture or water.  
Place on a moisture resistant surface.  
F
D
B
B
C
3. Remove the tank from the main housing.  
A. Tank  
B. Humidifier Base  
D. Transducer  
(not shown on  
4. Bring the tank to the sink, turn upside down and twist off the  
tank cap by turning counter clockwise. Fill tank with cool,  
fresh tap water. DO NOT fill with warm water as this may  
cause leaking. Replace the cap on tank FIRMLY. The tank  
capacity and run time for each model are listed below:  
C. Slider Wheel  
(not shown on  
BU5000/BU5200)  
BU5100/BU5200)  
F. Fan Outlet  
E. Humidifier Top Cover  
(BU5200 Only)  
(not shown on BU5200)  
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
BU5000_5100_5200-U_07EM2.qxd 7/23/07 13:49 Page 7  
5. Fill tank with cool, fresh tap water. DO NOT fill with warm  
water as this may cause leaking. Replace the cap on tank  
FIRMLY. Follow step 5-6 in pre-operating instructions.  
Gently scrub the area around the transducer with a soft  
brush. Remove the scale by wiping the entire base with  
a cloth dampened with undiluted white vinegar.  
WARNING: DO NOT move the humidifier with water in the  
tank or the humidifier base. The moving action of the water  
may activate the water tanks release nozzle and overfill the  
humidifier base. This may cause the humidifier to function  
intermittently, or stop emitting mist. Should this occur,  
simply remove the excess water from the humidifier base.  
3. Rinse clean with warm water to remove cleaning  
solution before disinfecting the tank.  
To Disinfect Tank  
1. Fill humidifier tank 1/2 full with water and 1/2  
tablespoon of chlorine bleach.  
IMPORTANT: If you do not plan to use your humidifier for  
two or more days, make sure any residual water is drained  
from the water tank and base to prevent any algae or  
bacteria growth in stagnant water. Make sure the tank is dry.  
2. Let the solution stand for 20 minutes, swishing every  
few minutes. Wet all surfaces.  
3. Carefully empty the tank after 20 minutes, and rinse  
with warm water until you can not detect any bleach  
smell. Dry with a clean cloth or paper towel.  
CLEANING AND MAINTENANCE INSTRUCTIONS  
4. Refill the water tank as directed in Operating  
Instructions, and turn the unit on.  
Humidifiers provide comfort by adding moisture to dry,  
heated indoor air. To benefit most from the humidifier and  
avoid product misuse, follow all instructions carefully.  
Please note that this is an electrical appliance and requires  
attention when in use.  
FREQUENTLY ASKED QUESTIONS  
QUESTIONS  
ANSWER  
In addition, if you do not follow the recommended care and  
maintenance guidelines, micro-organisms may be able to  
grow in the water within the humidifier's tank. You must  
routinely follow the cleaning procedures that follow in order  
to ensure proper, efficient operation of your humidifier.  
Proper maintenance and cleaning is essential to the  
continued performance of your unit and the avoidance of  
algae or bacteria build-up.  
The estimated run time for this  
humidifier is based on average room  
conditions. The actual run time of your  
humidifier is dependent on numerous  
variables such as:  
• What are the  
variables that  
affect run time?  
1. Air exchange in the room where  
the humidifier is placed.  
2. Room construction where the  
humidifier is placed.  
DAILY MAINTENANCE  
1. Be sure the unit is OFF and is disconnected from the  
electrical outlet  
2. Remove the tank from the humidifier and place in sink  
or tub.  
3. Drain any remaining water and rinse thoroughly to  
remove any sediment or dirt. Wipe clean and dry with a  
clean cloth or paper towel.  
3. Temperature of the room where  
the humidifier is placed.  
4. Humidity levels in the room where  
the humidifier is placed.  
5. Movement of occupants and the  
opening and closing of doors in the  
room where the humidifier is placed.  
6. Home furnishings in the room  
where the humidifier is placed.  
4. Refill with cool tap water. Do not overfill.  
WEEKLY MAINTENANCE  
See Daily Maintenance instructions.  
Regular cleaning is recommended.  
• How do I  
remove film on  
water tank?  
To Remove Scale:  
1. Repeat steps 1-3 above.  
• How can I  
extend the  
run time?  
1. Run your unit on the lowest setting.  
(not applicable to BU5200)  
2. Clean the base by partially filling  
Figure 2  
it with one 8-oz cups of undiluted  
2. Fill the tank all the way full, place it  
on the base, let the water empty  
into the base until it stops bubbling,  
then refill the tank full again. This  
ensures maximum water capacity  
and will extend run time.  
white vinegar or by using Cleanse  
TM  
Clean Solution (DMS216) by the  
manufacturer. Leave this solution  
in the tank for 20 minutes, while  
cleaning all interior surfaces with a  
soft brush.  
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
BU5000_5100_5200-U_07EM2.qxd 7/23/07 13:49 Page 9  
3. This humidifier is equipped with an agency required  
overflow feature. To prevent spillage or overflow of  
water, avoid tilting the humidifier while carrying.  
Troubleshooting for your  
Ultrasonic Humidifier  
Trouble  
Probable Cause  
Solution  
Should your humidifier require service, please call  
1-800-253-2764 in North America for further assistance.  
Tank rubber ring is  
missing.  
Remove tank  
cap and replace  
or reposition ring.  
• Water Leaks  
from tank  
Cap not tight enough.  
Tank water is Hot.  
Tighten the cap.  
Fill with cool  
water only.  
Hot water will cause Fill with cool  
• Crack in tank  
tank to pressurize.  
water only.  
Handle tank with  
Care.  
Tanks will crack if  
hit or dropped.  
• Film on tank Mineral deposits  
Clean/disinfect  
tank as instructed  
in weekly clean-  
ing instructions.  
Overflow Feature  
BU5000  
STORAGE INSTRUCTIONS  
When not using your humidifier for an extended period of  
time:  
1. Clean, rinse and thoroughly dry the humidifier as  
directed in weekly maintenance. DO NOT leave any  
water in the unit when storing. Leaving water in the unit  
may render the unit inoperable for the following season.  
2. Place the humidifier in the original carton and store in a  
cool, dry place.  
REPLACEMENT ACCESSORIES  
Overflow Feature  
To order the replacement accessories you can do any of  
the following:  
BU5100  
• Visit your local retailer  
• Call consumer service at 1-800-253-2764  
SERVICE INSTRUCTIONS  
1. Do NOT attempt to repair or adjust any electrical or  
mechanical functions on this unit. Doing so will void the  
warranty. The inside of humidifier contains no user  
serviceable parts. All servicing should be performed by  
qualified personnel only.  
2. If you need to exchange the unit, please return it in its  
original carton, with a sales receipt, to the store where  
you purchased it. If you are returning the unit more than  
30 days after the date of purchase, please see the  
enclosed warranty.  
Overflow Feature  
BU5200  
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
BU5000_5100_5200-U_07EM2.qxd 7/23/07 13:49 Page 11  
4. If you have any other questions or comments, feel free  
to write to us or visit our website  
Some provinces, states or jurisdictions do not allow the  
exclusion or limitation of incidental or consequential damages  
or limitations on how long an implied warranty lasts, so the  
above limitations or exclusion may not apply to you.  
This warranty gives you specific legal rights, and you may  
also have other rights that vary from province to province,  
state to state or jurisdiction to jurisdiction.  
1 YEAR LIMITED WARRANTY  
Sunbeam Products, Inc. doing business as Jarden  
Consumer Solutions or if in Canada, Sunbeam Corporation  
(Canada) Limited doing business as Jarden Consumer  
Solutions (collectively “JCS”) warrants that for a period of one  
year from the date of purchase, this product will be free from  
defects in material and workmanship. JCS, at its option, will  
repair or replace this product or any component of the  
product found to be defective during the warranty period.  
Replacement will be made with a new or remanufactured  
product or component. If the product is no longer available,  
replacement may be made with a similar product of equal or  
greater value. This is your exclusive warranty. Do NOT  
attempt to repair or adjust any electrical or mechanical  
functions on this product. Doing so will void this warranty.  
How to Obtain Warranty Service  
In the U.S.A.  
If you have any question regarding this warranty or would  
like to obtain warranty service, please call 1-800-253-2764  
and a convenient service center address will be provided  
to you.  
In Canada  
If you have any question regarding this warranty or would  
like to obtain warranty service, please call 1-800-253-2764  
and a convenient service center address will be provided  
to you.  
This warranty is valid for the original retail purchaser from  
the date of initial retail purchase and is not transferable.  
Keep the original sales receipt. Proof of purchase is  
required to obtain warranty performance. JCS dealers,  
service centers, or retail stores selling JCS products do not  
have the right to alter, modify or any way change the terms  
and conditions of this warranty.  
This warranty does not cover normal wear of parts or damage  
resulting from any of the following: negligent use or misuse of  
the product, use on improper voltage or current, use contrary  
to the operating instructions, disassembly, repair or alteration  
by anyone other than JCS or an authorized JCS service  
center. Further, the warranty does not cover: Acts of God,  
such as fire, flood, hurricanes and tornadoes.  
In the U.S.A., this warranty is offered by Sunbeam  
Products, Inc doing business as Jarden Consumer  
Solutions located in Boca Raton, Florida 33431. In  
Canada, this warranty is offered by Sunbeam Corporation  
(Canada) Limited doing business as Jarden Consumer  
Solutions, located at 20 Hereford Street, Brampton,  
Ontario L6Y 0M1. If you have any other problem or claim in  
connection with this product, please write our Consumer  
Service Department.  
PLEASE DO NOT RETURN THIS PRODUCT TO ANY  
OF THESE ADDRESSES OR TO THE PLACE OF  
PURCHASE.  
What are the limits on JCS’s Liability?  
JCS shall not be liable for any incidental or consequential  
damages caused by the breach of any express, implied or  
statutory warranty or condition.  
Except to the extent prohibited by applicable law, any implied  
warranty or condition of merchantability or fitness for a  
particular purpose is limited in duration to the JCS disclaims  
all other warranties, conditions or representations, express,  
implied, statutory or otherwise.  
JCS shall not be liable for any damages of any kind resulting  
from the purchase, use or misuse of, or inability to use the  
product including incidental, special, consequential or simi-  
lar damages or loss of profits, or for any breach of contract,  
fundamental or otherwise, or for any claim brought against  
purchaser by any other party.  
9
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Network Card F4D121 User Manual
Black Box Switch 10BASE T 100BASE TX GSHDSL Two Wire Extender NTU User Manual
Black Decker Food Processor FP1445 User Manual
Blaupunkt Car Stereo System CD 2001 User Manual
Blue Rhino Gas Grill HBT822W User Manual
Brinkmann Gas Grill 810 6830 B User Manual
Brinkmann Landscape Lighting ENDURA User Manual
Canon Digital Camera 220 HS User Manual
Canon Printer S200SP User Manual
Chicago Electric Portable Generator 94678 User Manual