BRK electronic Smoke Alarm SC01N User Manual

6. Line the mounting bracket up over the  
plastic screw anchors.  
ABOUT SMOKE ALARMS  
Battery (DC) operated Smoke Alarms: Provide protection even when  
electricity fails, provided the batteries are fresh and correctly installed. Units  
are easy to install, and do not require professional installation.  
HOW CAN I PROTECT MY FAMILY FROM  
CO POISONING?  
SPECIAL COMPLIANCE CONSIDERATIONS  
INSTALLATION  
WEEKLY TESTING  
WHERE TO INSTALL THIS ALARM  
7. Screw the mounting bracket to the ceiling  
or wall through the mounting slots using  
the two screws provided.  
A CO Alarm is an excellent means of protection. It monitors the air and  
sounds a loud alarm before Carbon Monoxide levels become threatening  
for average, healthy adults.  
NEVER use an open flame of any kind to test this unit. You might  
accidentally damage or set fire to the unit or to your home.  
The built-in test switch accurately tests the unit’s operation as  
required by Underwriters Laboratories, Inc. (UL). NEVER use  
vehicle exhaust! Exhaust may cause permanent damage and  
voids your warranty.  
Minimum coverage for Smoke Alarms, as recommended by the National  
Fire Protection Association (NFPA), is one Smoke Alarm on every floor, in  
every sleeping area, and in every bedroom (See “Regulatory Information For  
Smoke Alarms” for details on the NFPA recommendations).  
This unit alone is not a suitable substitute for complete fire detection  
systems in places housing many people—like apartment buildings,  
condominiums, hotels, motels, dormitories, hospitals, long-term health  
care facilities, nursing homes, day care facilities, or group homes of any  
kind—even if they were once single-family homes. It is not a suitable  
substitute for complete fire detection systems in warehouses, industrial  
facilities, commercial buildings, and special-purpose non-residential  
buildings which require special fire detection and alarm systems.  
Depending on the building codes in your area, this unit may be used to  
provide additional protection in these facilities.  
USER’S MANUAL  
AC powered Smoke Alarms: Can be interconnected so if one unit senses  
smoke, all units alarm. They do not operate if electricity fails.  
AC with battery (DC) back-up: will operate if electricity fails, provided the  
batteries are fresh and correctly installed. AC and AC/DC units must be  
installed by a qualified electrician.  
SMOKE AND CARBON MONOXIDE ALARM  
8. Before attaching the Alarm to the bracket,  
insert the 9V battery (included) into the  
battery compartment. Match the terminals  
on the end of the battery with the termi-  
nals on the unit. Match “+” to “+” and “-”  
to “-.” Push the battery in until it snaps in  
securely and cannot be shaken loose. If  
the battery is not snapped in completely,  
the unit cannot receive battery power.  
A CO Alarm is not a substitute for proper maintenance of home appliances.  
To help prevent CO problems and reduce the risk of CO poisoning:  
For CO Alarms, the National Fire Protection Association (NFPA) recommends  
that a CO Alarm should be centrally located outside of each separate sleeping  
area in the immediate vicinity of the bedrooms. For added protection, install  
additional CO Alarms in each separate bedroom, and on every level of your  
home.  
Features:  
Clean chimneys and flues yearly. Keep them free of debris, leaves, and  
nests for proper air flow. Also, have a professional check for rust and  
corrosion, cracks, or separations. These conditions can prevent proper  
air movement and cause backdrafting. Never “cap” or cover a chimney  
in any way that would block air flow.  
DO NOT stand close to the Alarm when the horn is sounding.  
Exposure at close range may be harmful to your hearing. When  
testing, step away when horn starts sounding.  
Separate sensors to detect smoke  
and CO. The two alarm systems  
work independently.  
Powered by a single 9V alkaline or  
lithium battery  
Smoke/CO Alarms for Solar or Wind Energy users and battery backup  
power systems: AC powered Smoke/CO Alarms should only be operated  
with true or pure sine wave inverters. Operating this Alarm with most battery-  
powered UPS (uninterruptible power supply) products or square wave or  
“quasi sine wave” inverters will damage the Alarm. If you are not sure about  
your inverter or UPS type, please consult with the manufacturer to verify.  
SERVICE  
BATTERY  
NOTE: For added protection, install an additional Smoke/CO Alarm at least  
20 feet (6 meters) away from the furnace or fuel burning heat source where  
possible. In smaller homes or in manufactured homes where this distance  
cannot be maintained, install the Alarm as far away as possible from the furnace  
or other fuel burning source. Installing the Alarm closer than 20 feet (6 meters)  
will not harm the Alarm, but may increase the frequency of nuisance alarms.  
TEST  
SILE  
The following information applies to all five types of buildings listed below:  
Test and maintain all fuel-burning equipment annually. Many local gas  
or oil companies and HVAC companies offer appliance inspections for  
a nominal fee.  
NCE  
It is important to test this unit every week to make sure it is working  
properly. Using the test button is the recommended way to test this  
Smoke/CO Alarm. Push and hold the Test/Silence button on the cover until  
you hear a “chirp.” The “chirp” marks the start of the self-test sequence.  
In new construction, most building codes require the use of AC or AC/DC  
powered Smoke Alarms only. AC, AC/DC, or DC powered Smoke Alarms can  
be used in existing construction as specified by local building codes. Refer to  
NFPA 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code), local  
building codes, or consult your Fire Department for detailed fire protection  
requirements in buildings not defined as “households.”  
Flip-open battery door for easy  
battery replacement  
NOTE: The unit may beep briefly when you  
install the battery. This is normal.  
The GREEN Light flashes about every  
30 seconds when the unit is receiving  
battery power.  
Smoke Alarms for the hearing impaired: Special purpose Smoke Alarms  
should be installed for the hearing impaired. They include a visual alarm and  
an audible alarm horn, and meet the requirements of the Americans With  
Disabilities Act. Can be interconnected so if one unit senses smoke, all units  
alarm.  
MOVE TO  
IR  
Make regular visual inspections of all fuel-burning appliances. Check  
appliances for excessive rust and scaling. Also check the flame on the  
burner and pilot lights. The flame should be blue. A yellow flame means  
fuel is not being burned completely and CO may be present. Keep the  
blower door on the furnace closed. Use vents or fans when they are  
available on all fuel-burning appliances. Make sure appliances are  
vented to the outside. Do not grill or barbecue indoors, or in garages  
or on screen porches.  
FRESH  
A
Large, easy-to-use Test button  
SMOKE  
CO  
Colored lights indicate “battery  
status” and “service needed.”  
First, the BATTERY (green) and SERVICE (yellow) lights will flash  
briefly—this is normal.  
In general, install combination Smoke and Carbon Monoxide Alarms:  
On every level of your home, including finished attics and basements.  
Next, the Smoke Alarm will sound. The smoke symbol will flash, and  
you will hear this horn pattern: 3 beeps, pause, 3 beeps, pause.  
1. Single-Family Residence:  
Single family home, townhouse. It is recommended this unit be installed on  
every level of the home, in every bedroom, and in each bedroom hallway.  
Inside every bedroom, especially if people sleep with the door partly or  
completely closed.  
Smoke alarms are not to be used with detector guards unless the  
combination has been evaluated and found suitable for that purpose.  
The battery door will not close unless a battery is installed. This warns  
you the unit will not operate without a battery.  
Finally, the CO Alarm will sound. The CO symbol will flash, and you  
will hear this horn pattern: 4 beeps, pause, 4 beeps, pause.  
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.  
LISTED TO  
In the hall near every sleeping area. If your home has multiple sleeping  
areas, install a unit in each. If a hall is more than 40 feet (12 meters) long,  
install a unit at each end.  
All these Smoke Alarms are designed to provide early warning of fires if  
located, installed and cared for as described in the user’s manual, and if  
smoke reaches the Alarm. If you are unsure which type of Smoke Alarm to  
install, refer the National Fire Protection Association (NFPA) Standard 72  
(National Fire Alarm Code) and NFPA 101 (Life Safety Code). National Fire  
Protection Association, One Batterymarch Park, Quincy, MA 02269-9101.  
Local building codes may also require specific units in new construction or  
in different areas of the home.  
2. Multi-Family or Mixed Occupant Residence:  
Check for exhaust backflow from CO sources. Check the draft hood  
on an operating furnace for a backdraft. Look for cracks on furnace  
heat exchangers.  
This user’s manual contains important information  
about your Smoke/CO Alarm’s operation.  
If you are installing this Smoke/CO Alarm for use by  
others, you must leave this manual—  
UL 217  
Apartment building, condominium. This unit is suitable for use in individual  
apartments or condos, provided a primary fire detection system already exists  
to meet fire detection requirements in common areas like lobbies, hallways, or  
porches. Using this unit in common areas may not provide sufficient warning  
to all residents or meet local fire protection ordinances/regulations.  
If the unit does not alarm, make sure the battery is correctly installed, and  
test again. If the unit still does not alarm, replace it immediately.  
and  
UL 2034  
Model SC01N  
At the top of first-to-second floor stairs.  
At the bottom of the basement stairs.  
Check the house or garage on the other side of shared wall.  
NOTE: During testing, if the yellow service light comes on and the horn  
“chirps” 3 times, the device should be serviced or replaced. After  
testing, if the horn starts to “chirp” every 30 seconds, replace the  
battery immediately.  
or a copy of it—with the end user.  
Keep windows and doors open slightly. If you suspect that CO is  
escaping into your home, open a window or a door. Opening windows  
and doors can significantly decrease CO levels.  
For additional coverage, install Alarms in all rooms, halls, and storage  
areas, where temperatures normally remain between 40˚F and 100˚F  
(4˚C and 38˚C).  
3. Institutions:  
M08-0015-003  
Q
08/07 Printed in Mexico  
Hospitals, day care facilities, long-term health care facilities. This unit is  
suitable for use in individual patient sleeping/resident rooms, provided a  
primary fire detection system already exists to meet fire detection require-  
ments in common areas like lobbies, hallways, or porches. Using this unit  
in common areas may not provide sufficient warning to all residents or meet  
local fire protection ordinances/regulations.  
In addition, familiarize yourself with all enclosed materials. Read this  
manual in its entirety, and make sure you understand what to do if your  
CO Alarm sounds.  
Recommended Placement  
SUGGESTED AREAS FOR INSTALLING  
9. Align the tabs on the base with the tabs on the mounting bracket.  
Turn the base until it snaps into place.  
REGULAR MAINTENANCE  
TABLE OF CONTENTS  
REGULATORY INFORMATION FOR  
SMOKE/CO ALARMS  
REGULATORY INFORMATION FOR CO ALARMS  
WHAT LEVELS OF CO CAUSE AN ALARM?  
Underwriters Laboratories Inc. Standard UL2034 requires residential CO  
Alarms to sound when exposed to levels of CO and exposure times as  
described below. They are measured in parts per million (ppm) of CO over  
time (in minutes).  
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3  
Where to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2  
Where This Alarm Should NOT Be Installed . . . . . . . . . . . . . . . . . . . . .2  
How to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3  
If Your Smoke/CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
What To Do First–Identify The Type Of Alarm . . . . . . . . . . . . . . . . . . . .3  
If the CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
If the Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . . . .4  
How Can I Protect My Family From CO Poisoning? . . . . . . . . . . . . . . . . .5  
Regulatory Information For Smoke/CO Alarms . . . . . . . . . . . . . . . . . . . . .5  
Regulatory Information for CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . .5  
Regulatory Information for Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . .5  
Recommended Locations for Smoke Alarms . . . . . . . . . . . . . . . . . . . .5  
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
General Limitations Of Smoke/CO Alarms . . . . . . . . . . . . . . . . . . . . . . .6-7  
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7  
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7  
10. If the cover does not line up the way you wanted, adjust it by slowly  
rotating it in either direction.  
SMOKE ALARMS, CO ALARMS, AND COMBO UNITS  
Use only the replacement batteries listed below. The unit may not  
operate properly with other batteries. Never use rechargeable batteries  
since they may not provide a constant charge.  
4. Hotels and Motels:  
KEY:  
Also boarding houses and dormitories. This unit is suitable for use inside  
individual sleeping/resident rooms, provided a primary fire detection system  
already exists to meet fire detection requirements in common areas like  
lobbies, hallways, or porches. Using this unit in common areas may not  
provide sufficient warning to all residents or meet local fire protection  
ordinances/regulations.  
11. Test the Smoke/CO Alarm. See “Weekly Testing” for details.  
SMOKE ALARMS  
This unit has been designed to be as maintenance-free as possible, but there  
are a few simple things you must do to keep it working properly:  
SMOKE ALARM WITH  
SILENCE FEATURE  
IF YOUR SMOKE/CO ALARM SOUNDS  
WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM  
Test it at least once a week.  
CO ALARMS  
Clean the Smoke/CO Alarm at least once a month; gently vacuum the  
outside of the Smoke/CO Alarm using your household vacuum’s soft  
brush attachment. Test the Smoke/CO Alarm. Never use water, cleaners  
or solvents since they may damage the unit.  
5. Warehouses/Commercial Buildings:  
BOTH, OR COMBINATION  
SMOKE/CO ALARMS  
Type of Alarm  
What You See and Hear  
DO NOT use this Smoke/CO Alarm in warehouses, industrial or commercial  
buildings, special-purpose non-residential buildings, RVs, boats, or airplanes.  
This Smoke/CO Alarm is specifically designed for residential use, and may  
not provide adequate protection in non-residential applications.  
UL2034 Required Alarm Points*:  
Carbon Monoxide (CO)  
CO Light:  
Suggested locations are based on  
NFPA recommendations (NFPA 72  
for Smoke Alarms and NFPA 720 for  
Carbon Monoxide Alarms). Always  
refer to national and local codes  
before beginning any installation.  
If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN  
4 and 15 MINUTES.  
If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN  
10 and 50 MINUTES.  
If the alarm is exposed to 70 ppm if CO, IT MUST ALARM BETWEEN  
60 and 240 MINUTES.  
Flashing RED  
Horn: 4 beeps,  
If the Smoke/CO Alarm becomes contaminated by excessive dirt, dust  
and/or grime, and cannot be cleaned to avoid unwanted alarms, replace  
the unit immediately.  
pause, 4 beeps, pause  
Relocate the unit if it sounds frequent unwanted alarms. See “Where This  
Alarm Should Not Be Installed” for details.  
In new construction AC and AC/DC smoke alarms MUST  
be interconnected to meet NFPA recommendations.  
Smoke  
Smoke Light:  
Flashing RED  
Horn: 3 beeps,  
pause, 3 beeps, pause  
Choosing a replacement battery:  
* Approximately 10% COHb exposure at levels of 10% to 95% Relative  
Humidity (RH).  
The unit is designed not to alarm when exposed to a constant level  
of 30 ppm for 30 days.  
When installing on the wall, the top edge of Smoke Alarms should be  
placed between 4 inches (102 mm) and 12 inches (305 mm) from the  
wall/ceiling line.  
Your Smoke/CO Alarm requires one standard 9V battery. The following  
batteries are acceptable as replacements: Duracell #MN1604, (Ultra) #MX1604;  
Eveready (Energizer) #522. You may also use a Lithium battery like the Ultralife  
U9VL-J for longer service life between battery changes. These batteries are  
available at many local retail stores.  
Problem...  
What You See  
and Hear  
Indicates:  
You Should...  
When installing on the ceiling, place the alarm as close to the center  
as possible.  
GENERAL LIMITATIONS OF SMOKE/CO ALARMS  
CO Alarms are designed to alarm before there is an immediate life threat.  
Since you cannot see or smell CO, never assume it’s not present.  
This Smoke/CO Alarm is intended for residential use. It is not intended for use  
in industrial applications where Occupational Safety and Health Administration  
(OSHA) requirements for Carbon Monoxide Alarms must be met. The Smoke  
Alarm portion of this device is not intended to alert hearing impaired residents.  
Special purpose Smoke Alarms should be installed for hearing impaired resi-  
dents (CO Alarms are not yet available for the hearing impaired).  
not give adequate early warning. Recommended minimum protection is one  
alarm device in every sleeping area, every bedroom, and on every level of your  
home. Some experts recommend battery powered Smoke and CO Alarms be  
used in conjunction with interconnected AC powered Smoke Alarms. For  
details, see “About Smoke Alarms” for details.  
Low Battery  
Battery Light:  
Battery is Low:  
Install new 9V alkaline or  
lithium battery. For a list of  
acceptable replacement  
batteries, see “Regular  
Maintenance.”  
In either case, install at least 4 inches (102 mm) from where the wall and  
ceiling meet. See “Avoiding Dead Air Spaces” for more information.  
Flashing GREEN  
Horn: Chirps  
An exposure to 100 ppm of CO for 20 minutes may not affect average,  
healthy adults, but after 4 hours the same level may cause headaches.  
Actual battery service life depends on the Smoke/CO Alarm and the environ-  
ment in which it is installed. All the batteries specified above are acceptable  
replacement batteries for this unit. Regardless of the manufacturer’s suggested  
battery life, you MUST replace the battery immediately once the unit starts  
“chirping” (the “low battery warning”).  
NOTE: For any location, make sure no door or other obstruction could keep  
carbon monoxide or smoke from reaching the Alarm.  
every 30 seconds  
An exposure to 400 ppm of CO may cause headaches in average, healthy  
adults after 35 minutes, but can cause death after 2 hours.  
Smoke/CO Alarms may not be heard. The alarm horn loudness meets or  
exceeds current UL standards of 85 dB at 10 feet (3 meters). However, if  
the Smoke/CO Alarm is installed outside the bedroom, it may not wake up  
a sound sleeper or one who has recently used drugs or has been drinking  
alcoholic beverages. This is especially true if the door is closed or only partly  
open. Even persons who are awake may not hear the alarm horn if the sound  
is blocked by distance or closed doors. Noise from traffic, stereo, radio,  
television, air conditioner, or other appliances may also prevent alert persons  
from hearing the alarm horn. This Smoke/CO Alarm is not intended for people  
who are hearing impaired.  
Installing Smoke/CO Alarms in Mobile Homes  
Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon  
monoxide alarms UL2034.  
Smoke/CO Alarms may not waken all individuals. Practice the escape  
plan at least twice a year, making sure that everyone is involved – from kids  
to grandparents. Allow children to master fire escape planning and practice  
before holding a fire drill at night when they are sleeping. If children or others  
do not readily waken to the sound of the Smoke/CO Alarm, or if there are  
infants or family members with mobility limitations, make sure that someone  
is assigned to assist them in fire drill and in the event of an emergency. It is  
recommended that you hold a fire drill while family members are sleeping in  
order to determine their response to the sound of the Smoke/CO Alarm while  
sleeping and to determine whether they may need assistance in the event of  
an emergency.  
Service  
Service Light:  
Device is not Working  
Properly: See “Testing  
and Maintenance”.  
For minimum security install one Smoke/CO Alarm as close to each sleeping  
area as possible. For more security, put one unit in each room. Many older  
mobile homes (especially those built before 1978) have little or no insulation.  
If your mobile home is not well insulated, or if you are unsure of the amount  
of insulation, it is important to install units on inside walls only.  
Flashing YELLOW  
Horn: 3 quick chirps  
every 30 seconds  
According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon  
monoxide alarms covered by these requirements are intended to respond to  
the presence of carbon monoxide from sources such as, but not limited to,  
exhaust from internal-combustion engines, abnormal operation of fuel-fired  
appliances, and fireplaces. CO Alarms are intended to alarm at carbon  
monoxide levels below those that could cause a loss of ability to react to the  
dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at  
the Alarm, and is designed to alarm before CO levels become life threatening.  
This allows you precious time to leave the house and correct the problem.  
This is only possible if Alarms are located, installed, and maintained as  
described in this manual.  
WHAT YOU NEED TO KNOW ABOUT CO  
WHAT IS CO?  
CO is an invisible, odorless, tasteless gas produced when fossil fuels do not  
burn completely, or are exposed to heat (usually fire). Electrical appliances  
typically do not produce CO.  
These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene,  
and propane.  
Common appliances are often sources of CO. If they are not properly main-  
tained, are improperly ventilated, or malfunction, CO levels can rise quickly.  
CO is a real danger now that homes are more energy efficient. “Air-tight”  
homes with added insulation, sealed windows, and other weatherproofing  
can “trap” CO inside.  
© 2007 BRK Brands, Inc., a Jarden Corporation company (NYSE: JAH)  
3901 Liberty Street Road, Aurora, IL 60504-8122  
All rights reserved.  
Consumer Affairs: (800) 323-9005 • www.firstalert.com  
IF THE CO ALARM SOUNDS  
WHERE THIS ALARM SHOULD NOT BE INSTALLED  
Do NOT locate this Smoke/CO Alarm:  
®
All First Alert Smoke Alarms conform to regulatory requirements,  
including UL217 and are designed to detect particles of combustion.  
Smoke particles of varying number and size are produced in all fires.  
“ALARM-MOVE TO FRESH AIR”  
The Alarm may not have time to alarm before the fire itself causes  
damage, injury, or death, since smoke from some fires may not reach  
the unit immediately. Examples of this include persons smoking in bed,  
children playing with matches, or fires caused by violent explosions  
resulting from escaping gas.  
In garages, kitchens, furnace rooms, crawl spaces and unfinished attics.  
Avoid extremely dusty, dirty or greasy areas.  
If you hear the alarm horn sound 4 beeps,  
pause, 4 beeps, pause, and the RED CO  
light is flashing, move everyone to a source  
of fresh air.  
Smoke/CO Alarms cannot work without power. Battery operated units cannot  
work if the batteries are missing, disconnected or dead, if the wrong type of  
batteries are used, or if the batteries are not installed correctly. AC units cannot  
work if the AC power is cut off for any reason (open fuse or circuit breaker, failure  
along a power line or at a power station, electrical fire that burns the electrical  
wires, etc.). If you are concerned about the limitations of battery or AC power,  
install both types of units.  
Ionization technology is generally more sensitive than photoelectric  
technology at detecting small particles, which tend to be produced  
in greater amounts by flaming fires, which consume combustible  
materials rapidly and spread quickly. Sources of these fires may include  
paper burning in a wastebasket, or a grease fire in the kitchen.  
Where combustion particles are produced. Combustion particles form  
when something burns. Areas to avoid include poorly ventilated kitchens,  
garages, and furnace rooms. Keep units at least 20 feet (6 meters) from  
the sources of combustion particles (stove, furnace, water heater, space  
heater) if possible. In areas where a 20-foot distance is not possible –  
in modular, mobile, or smaller homes, for example – it is recommended  
the Smoke Alarm be placed as far from these fuel-burning sources as  
possible. The placement recommendations are intended to keep these  
Alarms at a reasonable distance from a fuel-burning source, and thus  
reduce “unwanted” or “nuisance” alarms. Unwanted alarms can occur if  
a Smoke Alarm is placed directly next to a fuel-burning source. Ventilate  
these areas as much as possible.  
Gas Detection at Typical Temperature and Humidity Ranges: The CO  
Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested  
for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane  
(500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon  
Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts  
per million.  
This Smoke/CO Alarm is not a substitute for life insurance. Though this  
Smoke/CO Alarm warns against increasing CO levels or the presence of  
smoke, BRK Brands, Inc. does not warrant or imply in any way that they will  
protect lives. Homeowners and renters must still insure their lives.  
SYMPTOMS OF CO POISONING  
These symptoms are related to CO POISONING and should be discussed  
with ALL household members.  
Photoelectric technology is generally more sensitive than ionization  
technology at detecting large particles, which tend to be produced in  
greater amounts by smoldering fires, which may smolder for hours  
before bursting into flame. Sources of these fires may include cigarettes  
burning in couches or bedding.  
Actuation of your CO Alarm indicates the presence of carbon monoxide  
(CO) which can kill you. In other words, when your CO Alarm sounds, you  
must not ignore it!  
This Smoke/CO Alarm will not sense smoke or CO that does not reach  
the sensors. It will only sense smoke or CO at the sensor. Smoke or CO may  
be present in other areas. Doors or other obstructions may affect the rate at  
which CO or smoke reaches the sensors. If bedroom doors are usually closed  
at night, we recommend you install an alarm device (Combination CO and  
Smoke Alarm, or separate CO Alarms and Smoke Alarms) in each bedroom  
and in the hallway between them.  
This Smoke/CO Alarm has a limited life. Although this Smoke/CO Alarm  
and all of its parts have passed many stringent tests and are designed to be  
as reliable as possible, any of these parts could fail at any time. Therefore,  
you must test this device weekly. The unit should be replaced immediately  
if it is not operating properly.  
Audible Alarm: 85 dB minimum at 10 feet (3 meters).  
Mild Exposure: Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).  
Medium Exposure: Throbbing headache, drowsiness, confusion, fast heart rate.  
IF THE CO ALARM SOUNDS:  
1. Operate the Test/Silence button.  
REGULATORY INFORMATION FOR SMOKE ALARMS  
RECOMMENDED LOCATIONS FOR SMOKE ALARMS  
Installing Smoke Alarms in Single-Family Residences  
The National Fire Protection Association (NFPA), recommends one Smoke  
Alarm on every floor, in every sleeping area, and in every bedroom. In new  
construction, the Smoke Alarms must be AC powered and interconnected.  
See “Agency Placement Recommendations” for details. For additional cover-  
age, it is recommended that you install a Smoke Alarm in all rooms, halls,  
storage areas, finished attics, and basements, where temperatures normally  
remain between 40˚F (4˚C) and 100˚F (38˚C). Make sure no door or other  
obstruction could keep smoke from reaching the Smoke Alarms.  
For maximum protection, use both types of Smoke Alarms on each  
level and in every bedroom of your home.  
2. Call your emergency services, fire department or 911. Write down the  
number of your local emergency service here:  
Extreme Exposure: Convulsions, unconsciousness, heart and lung failure.  
Exposure to Carbon Monoxide can cause brain damage, death.  
Within 5 feet (1.5 meters) of any cooking appliance. In air streams near  
kitchens. Air currents can draw cooking smoke into the smoke sensor  
and cause unwanted alarms.  
This Smoke/CO Alarm is not foolproof. Like all other electronic devices,  
this Smoke/CO Alarm has limitations. It can only detect smoke or CO that  
reaches the sensors. It may not give early warning of the source of smoke  
or CO is in a remote part of the home, away from the alarm device.  
This Smoke/CO Alarm may not sense smoke or CO on another level of  
the home. Example: This alarm device, installed on the second floor, may not  
sense smoke or CO in the basement. For this reason, one alarm device may  
__________________________________________________________________  
INTRODUCTION  
FIRE SAFETY TIPS  
Follow safety rules and prevent hazardous situations: 1) Use smoking  
materials properly. Never smoke in bed. 2) Keep matches or lighters away from  
children; 3) Store flammable materials in proper containers; 4) Keep electrical  
appliances in good condition and don’t overload electrical circuits; 5) Keep  
stoves, barbecue grills, fireplaces and chimneys grease- and debris-free;  
6) Never leave anything cooking on the stove unattended; 7) Keep portable  
heaters and open flames, like candles, away from flammable materials;  
8) Don’t let rubbish accumulate.  
This CO Alarm measures exposure to CO over time. It alarms if CO levels  
are extremely high in a short period of time, or if CO levels reach a certain  
minimum over a long period of time. The CO Alarm generally sounds an  
alarm before the onset of symptoms in average, healthy adults. Why is this  
important? Because you need to be warned of a potential CO problem while  
you can still react in time. In many reported cases of CO exposure, victims  
may be aware that they are not feeling well, but become disoriented and  
can no longer react well enough to exit the building or get help. Also, young  
children and pets may be the first affected. The average healthy adult might  
not feel any symptoms when the CO Alarm sounds. However, people with  
cardiac or respiratory problems, infants, unborn babies, pregnant mothers,  
or elderly people can be more quickly and severely affected by CO. If you  
experience even mild symptoms of CO poisoning, consult your doctor  
immediately!  
In extremely humid areas. This Alarm should be at least 10 feet (3 meters)  
from a shower, sauna, humidifier, vaporizer, dishwasher, laundry room,  
utility room, or other source of high humidity.  
3. Immediately move to fresh air—outdoors or by an open door or window.  
Do a head count to check that all persons are accounted for. Do not re-  
enter the premises, or move away from the open door or window until the  
emergency services responder has arrived, the premises have been aired  
out, and your CO Alarm remains in its normal condition.  
In direct sunlight.  
TROUBLESHOOTING GUIDE  
In turbulent air, like near ceiling fans or open windows. Blowing air may  
prevent CO or smoke from reaching the sensors.  
4. After following steps 1-3, if your CO Alarm reactivates within a 24-hour  
period, repeat steps 1-3 and call a qualified appliance technician to inves-  
tigate for sources of CO from fuel-burning equipment and appliances, and  
inspect for proper operation of this equipment. If problems are identified  
during this inspection have the equipment serviced immediately. Note any  
combustion equipment not inspected by the technician, and consult the  
manufacturers’ instructions, or contact the manufacturers directly, for more  
information about CO safety and this equipment. Make sure that motor  
vehicles are not, and have not, been operating in an attached garage or  
adjacent to the residence. Write down the number of a qualified appliance  
technician here:  
More specifically, install Smoke Alarms:  
If the Alarm...  
Problem...  
You should...  
On every level of your home, including finished attics and basements.  
Inside every bedroom, especially if people sleep with the door partly or  
completely closed.  
In areas where temperature is colder than 40˚F (4˚C) or hotter than 100˚F  
(38˚C). These areas include non-airconditioned crawl spaces, unfinished  
attics, uninsulated or poorly insulated ceilings, porches, and garages.  
The BATTERY light flashes GREEN and the horn  
“chirps” every 30 seconds.  
Low battery warning.  
Install a new 9V alkaline or lithium battery*.  
In the hall near every sleeping area. If your home has multiple sleeping  
areas, install a unit in each. If a hall is more than 40 feet long (12 meters),  
install a unit at each end.  
At the top of the first-to-second floor stairway, and at the bottom  
of the basement stairway.  
Keep alarms clean, and test them weekly. Replace alarms immediately if they  
are not working properly. Smoke Alarms that do not work cannot alert you  
to a fire. Keep at least one working fire extinguisher on every floor, and an  
additional one in the kitchen. Have fire escape ladders or other reliable means  
of escape from an upper floor in case stairs are blocked.  
In insect infested areas. Insects can clog the openings to the sensing  
chamber.  
Horn chirps and yellow service light blinks three times  
every 30 seconds.  
Device is not working properly, and needs to be  
replaced.  
Units under warranty should be returned to  
manufacturer for replacement. See “Limited  
Warranty” for details.  
Less than 12 inches (305 mm) away from fluorescent lights. Electrical  
“noise” can interfere with the sensor.  
FINDING THE SOURCE OF CO AFTER AN ALARM  
Carbon monoxide is an odorless, invisible gas, which often makes it difficult  
to locate the source of CO after an alarm. These are a few of the factors that  
can make it difficult to locate sources of CO:  
In “dead air” spaces. See “Avoiding Dead Air Spaces”.  
Carbon Monoxide Alarm ONLY:  
__________________________________________________________________  
Specific requirements for Smoke Alarm installation vary from state to state  
and from region to region. Check with your local Fire Department for current  
requirements in your area. It is recommended AC or AC/DC units be inter-  
connected for added protection.  
BASIC SAFETY INFORMATION  
AVOIDING DEAD AIR SPACES  
“Dead air” spaces may prevent smoke from reaching the Smoke/CO Alarm.  
To avoid dead air spaces, follow installation recommendations below.  
CO Alarm goes back into alarm 4 minutes after you  
press the Test/Silence button.  
CO levels indicate a potentially dangerous situation.  
IF YOU ARE FEELING SYMPTOMS OF CO  
House well ventilated before the investigator arrives.  
Problem caused by “backdrafting.”  
POISONING, EVACUATE your home and call 911 or  
the Fire Department. If not, press the Test/Silence  
button again and keep ventilating your home.  
IF THE SMOKE ALARM SOUNDS  
RESPONDING TO AN ALARM  
Dangers, Warnings, and Cautions alert you to important  
operating instructions or to potentially hazardous situations.  
Pay special attention to these items.  
On ceilings, install Smoke/CO Alarms as close to the center of the ceiling as  
possible. If this is not possible, install the Smoke/CO Alarm at least 4 inches  
(102 mm) from the wall or corner.  
Transient CO problem caused by special circumstances.  
Because CO may dissipate by the time an investigator arrives, it may be  
difficult to locate the source of CO. BRK Brands, Inc. shall not be obligated  
to pay for any carbon monoxide investigation or service call.  
CO Alarm sounds frequently even though no high  
levels of CO are revealed in an investigation.  
The CO Alarm may be improperly located. Refer to  
“Where to Install This Alarm.”  
Relocate your Alarm. If frequent alarms continue,  
have home rechecked for potential CO problems.  
You may be experiencing an intermittent CO  
problem.  
This Smoke/CO Alarm is approved for use in single-family  
residences. It is NOT designed for marine or RV use.  
If you hear the alarm horn sound 3 beeps, pause,  
3 beeps, pause and the RED SMOKE light is flashing,  
smoke has been detected. Evacuate everyone from  
the building.  
For wall mounting (if allowed by building codes), the top edge of Smoke/CO  
Alarms should be placed between 4 inches (102 mm) and 12 inches (305 mm)  
from the wall/ceiling line, below typical “dead air” spaces.  
POTENTIAL SOURCES OF CO IN THE HOME  
This combination Smoke/Carbon Monoxide Alarm has two separate  
alarms. The CO Alarm is not designed to detect fire or any other gas.  
It will only indicate the presence of carbon monoxide gas at the  
sensor. Carbon monoxide gas may be present in other areas. The  
Smoke Alarm will only indicate the presence of smoke that reaches  
the sensor. The Smoke Alarm is not designed to sense gas, heat or  
flames.  
On a peaked, gabled, or cathedral ceiling, install first Smoke/CO Alarm  
within 3 feet (0.9 meters) of the peak of the ceiling, measured horizontally.  
Additional Smoke/CO Alarms may be required depending on the length, angle,  
etc. of the ceiling's slope. Refer to NFPA 72 for details on requirements for  
sloped or peaked ceilings.  
Smoke Alarm ONLY:  
Fuel-burning appliances like:  
portable heater, gas or wood  
burning fireplace, gas kitchen  
range or cooktop, gas clothes  
dryer.  
Damaged or insufficient vent-  
ing: corroded or disconnected  
water heater vent pipe, leaking  
chimney pipe or flue, or cracked  
heat exchanger, blocked or  
clogged chimney opening.  
Improper use of appliance/  
device: operating a barbecue  
grill or vehicle in an enclosed  
area (like a garage or screened  
porch).  
Smoke Alarm sounds when no smoke is visible.  
Unwanted alarm may be caused by non-emergency  
source like cooking smoke.  
Clean the Alarm’s cover with a soft, clean cloth. If  
frequent unwanted alarms continue, relocate your  
Alarm. Alarm may be too close to a kitchen, cooking  
appliance, or steamy bathroom.  
If the unit alarms and you are not testing the unit, it is warning you  
of a potentially dangerous situation that requires your immediate  
attention. NEVER ignore any alarm. Ignoring the alarm may result in  
injury or death.  
Never remove the batteries from a battery operated Smoke Alarm to  
stop an unwanted alarm (caused by cooking smoke, etc.). Removing  
batteries disables the alarm so it cannot sense smoke, and removes  
your protection. Instead open a window or fan the smoke away from  
the unit. The alarm will reset automatically.  
HOW TO INSTALL THIS ALARM  
*For a list of acceptable replacement batteries, see “Regular Maintenance.”  
This Smoke/CO Alarm cannot operate without a working battery.  
Removing the battery for any reason, or failing to replace the battery  
at the end of its service life, removes your protection.  
If you have questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005, M-F 7:30 a.m. to 5:00 p.m. (CST)  
This combination Smoke/CO Alarm was designed to be mounted on the  
ceiling or wall. It is not a tabletop device. You must install this device on the  
ceiling or wall as outlined below. Read “Where To Install This Alarm” before  
starting.  
NEVER ignore any alarm. See “If Your Smoke/CO Alarm Sounds” for  
more information on how to respond to an alarm. Failure to respond  
can result in injury or death.  
INSTALLING SMOKE ALARMS IN MOBILE HOMES  
If the unit alarms get everyone out of the house immediately.  
Tools you will need: pencil, drill with 3/16” or 5mm drill bit,  
flathead screwdriver, hammer.  
For minimum security install one Smoke Alarm as close to each sleeping area as  
possible. For more security, put one unit in each room. Many older mobile homes  
(especially those built before 1978) have little or no insulation. If your mobile  
home is not well insulated, or if you are unsure of the amount of insulation, it is  
important to install units on inside walls only. Smoke Alarms should be installed  
where temperatures normally remain between 40˚F (4˚C) and 100˚F (38˚C).  
WHAT TO DO IN CASE OF FIRE  
LIMITED WARRANTY  
• Don’t panic; stay calm. Follow your family escape plan.  
• Get out of the house as quickly as possible. Don’t stop to get  
dressed or collect anything.  
• Feel doors with the back of your hand before opening them.  
If a door is cool, open it slowly. Don’t open a hot door. Keep doors  
and windows closed, unless you must escape through them.  
• Cover your nose and mouth with a cloth (preferably damp).  
Take short, shallow breaths.  
• Meet at your planned meeting place outside your home,  
and do a head count to make sure everybody got out safely.  
• Call the Fire Department as soon as possible from outside.  
Give your address, then your name.  
• Never go back inside a burning building for any reason.  
• Contact your Fire Department for ideas on making your home safer.  
BRK Brands, Inc., ("BRK") the maker of First Alert® brand products warrants that for a period of five years from the date of purchase, this product will be free from  
defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty  
period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar  
product of equal or greater value. This is your exclusive warranty.  
The Silence Feature is for your convenience only and will not  
correct a Smoke/CO problem. Always check your home for a  
potential problem after any alarm. Failure to do so can result in  
injury or death.  
PREPARE YOUR ALARM LABELS  
Find the pair of self-adhesive labels included with this Smoke/CO Alarm.  
Transient CO Problems: “transient” or on-again-off-again CO problems can  
be caused by outdoor conditions and other special circumstances.  
On each label write in the phone number of your emergency responder  
(like 911) and a qualified appliance technician.  
The following conditions can result in transient CO situations:  
Test this Smoke/CO Alarm once a week. If the Alarm ever fails to test  
correctly, have it replaced immediately! If the Alarm is not working  
properly, it cannot alert you to a problem.  
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is  
required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way change  
the terms and conditions of this warranty.  
AGENCY PLACEMENT RECOMMENDATIONS  
Place one label near the Smoke/CO Alarm, and the other label in the  
“fresh air” location you plan to go if the alarm sounds.  
1. Excessive spillage or reverse venting of fuel appliances caused by outdoor  
conditions such as:  
This equipment should be installed in accordance with NFPA (National Fire  
Protection Association) 72 and 101. National Fire Protection Association,  
One Batterymarch Park, Quincy, MA 02269-9101. Additional local building  
and regulatory codes may apply in your area. Always check compliance  
requirements before beginning any installation.  
Standards: Underwriters Laboratories Inc. Single and Multiple Station Smoke  
Alarms 217.  
NOTE: A qualified appliance technician is defined as “a person, firm,  
corporation, or company that either in person or through a representative, is  
engaged in and responsible for the installation, testing, servicing, or replace-  
ment of heating, ventilation, air conditioning (HVAC) equipment, combustion  
appliances and equipment, and/or gas fireplaces or other decorative com-  
bustion equipment.”  
Wind direction and/or velocity, including high, gusty winds. Heavy air in  
the vent pipes (cold/humid air with extended periods between cycles).  
This product is intended for use in ordinary indoor locations of  
family living units. It is not designed to measure CO levels in  
compliance with Occupational Safety and Health Administration  
(OSHA) commercial or industrial standards. Individuals with  
medical conditions that may make them more sensitive to carbon  
monoxide may consider using warning devices which provide  
audible and visual signals for carbon monoxide concentrations  
under 30 ppm. For additional information on carbon monoxide  
and your medical condition contact your physician.  
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or  
current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the warranty  
does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.  
Negative pressure differential resulting from the use of exhaust fans.  
Several appliances running at the same time competing for limited  
fresh air.  
BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by  
applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states,  
provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the  
above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or  
province to province.  
Vent pipe connections vibrating loose from clothes dryers, furnaces,  
or water heaters.  
NFPA 72 (National Fire Code)  
Do not connect this unit to any other alarm or auxiliary device.  
It is a single-station unit that cannot be linked to other devices.  
Connecting anything else to this unit may prevent it from working  
properly.  
Smoke Alarms shall be installed in each separate sleeping room, outside each  
sleeping area in the immediate vicinity of the bedrooms and on each additional  
story of the family living unit, including basements and excluding crawl spaces  
and unfinished attics.  
In new construction, Alarms shall be so arranged that operation of any one  
Alarm shall cause the operation of all Alarms within the dwelling.  
Obstructions in or unconventional vent pipe designs which can amplify  
the above situations.  
Alarms have various limitations. See "General Limitations of Smoke/CO  
Alarms" for details.  
How to Obtain Warranty Service  
Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005,  
2. Extended operation of unvented fuel burning devices (range, oven, fireplace).  
3. Temperature inversions, which can trap exhaust close to the ground.  
4. Car idling in an open or closed attached garage, or near a home.  
7:30 AM - 5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you, please have the model number and date of purchase available when  
Do not install this unit over an electrical junction box. Air currents  
around junction boxes can prevent smoke from reaching the sens-  
ing chamber and prevent the unit from alarming. Only AC powered  
units are intended for installation over junction boxes.  
USING THE SILENCE FEATURE  
calling.  
25 Spur Drive, El Paso, TX 79906.  
Never remove the batteries to quiet an unwanted alarm. Removing the  
batteries disables the alarm and removes your protection.  
Smoke Detection-Are More Smoke Alarms Desirable? The required number  
of Smoke Alarms might not provide reliable early warning protection for those  
areas separated by a door from the areas protected by the required Smoke  
Alarms. For this reason, it is recommended that the householder consider the  
use of additional Smoke Alarms for those areas for increased protection. The  
additional areas include the basement, bedrooms, dining room, furnace room,  
utility room, and hallways not protected by the required Smoke Alarms.  
The installation of Smoke Alarms in kitchens, attics (finished or unfinished),  
or garages is not normally recommended, as these locations occasionally  
experience conditions that can result in improper operation.  
Battery: BRK Brands, Inc. make no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose  
with respect to battery.  
These conditions are dangerous because they can trap exhaust in your home.  
Since these conditions can come and go, they are also hard to recreate  
during a CO investigation.  
1. Hold base firmly and twist the mounting  
bracket counterclockwise (left) to separate  
it from the unit.  
The Silence Feature is intended to temporarily silence the horn while you  
identify and correct the problem. Do not use the Silence Feature in emergency  
situations. It will not correct a CO problem or extinguish a fire.  
2. Hold the mounting bracket against the  
ceiling (or wall) and use a pencil to mark  
the center of each mounting slot.  
To use the Silence Feature, press and hold the Test/Silence button on the  
cover of the Smoke/CO Alarm for 3 seconds.  
For your records, please record:  
When the Smoke Alarm is Silenced  
When the CO Alarm is silenced  
3. Put the unit where it won’t get covered  
with dust when you drill the mounting holes.  
Date Purchased: ______________________________  
California State Fire Marshal (CSFM)  
The Smoke Alarm will remain silent  
for 8 minutes, then return to normal  
operation.  
The CO alarm will remain silent for  
4 minutes.  
4. Using a 3/16-inch (5 mm) drill bit, drill a hole through each pencil mark.  
Early warning detection is best achieved by the installation of fire detection  
equipment in all rooms and areas of the household as follows: A Smoke Alarm  
installed in each separate sleeping area (in the vicinity, but outside bedrooms),  
and Heat or Smoke Alarms in the living rooms, dining rooms, bedrooms,  
kitchens, hallways, finished attics, furnace rooms, closets, utility and storage  
rooms, basements, and attached garages.  
Where Purchased: _________________________________________  
5. Insert the plastic screw anchors into the holes. Tap the screw anchors  
gently with a hammer, if necessary, until they are flush with the ceiling or  
wall.  
After 4 minutes, if CO levels remain  
potentially dangerous the horn will  
start sounding again.  
First Alert® is a registered trademark of the First Alert Trust.  
If the smoke has not cleared–or  
continues to increase–the device  
will go back into alarm.  
Continued...  
Printed in Mexico M08-0015-003  
Q
08/07  
5
6
7
1
2
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Network Card F6D301 User Manual
Belshaw Brothers Convection Oven 10 Tray User Manual
Black Box Network Hardware 17 port Modular Ethernet Switch User Manual
Black Decker Paint Sprayer GSC500 User Manual
Bosch Appliances TV Mount LTC 9349MK User Manual
Boss Audio Systems Speaker AR12D User Manual
Briggs Stratton Lawn Mower 1687079 User Manual
Canon Projector SX60 User Manual
Carson Automobile Alarm SA 380 User Manual
Chauvet Webcam ART 575W User Manual