MODEL CO3000BN—User’s Manual
Batter y-Operated Carbon Monoxide Alarm
M06-1050-000 8/99
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1: Introduction
BASIC SAFETY INFORMATION
WARNING!
This CO Alarm does not operate without a
working battery. Removing the battery, or
failure to replace it at the end of its service
life, removes your protection.
IMPORTANT!
Dangers, Warnings, and Cautions alert you to
important operating instructions or to
potentially hazardous situations. Pay special
attention to these items.
WARNING!
NEVER ignore your carbon monoxide alarm
if it alarms. Refer to “What To Do If Your CO
Alarm Alarms” for more information. Failure
to do so can result in injury or death.
IMPORTANT!
THIS IS NOT A SMOKE ALARM! This CO Alarm
is designed to detect carbon monoxide from
ANY source of combustion. It is NOT designed
to detect smoke, fire, or any other gas.
WARNING!
Test the CO Alarm once a week. If the CO
Alarm ever fails to test correctly, have it
replaced immediately! If the CO Alarm is not
working properly, it cannot alert you to a
problem.
IMPORTANT!
This CO Alarm is approved for use in single-
family residences. It is NOT designed for marine
use.
WARNING!
CAUTION!
This product is intended for use in ordinary
indoor locations of family living units. It is
not designed to measure CO levels in
compliance with Occupational Safety and
Health Administration (OSHA) commercial or
industrial standards. Individuals with
medical conditions may consider using
warning devices which provide audible and
visual signals for carbon monoxide
This CO Alarm will only indicate the
presence of carbon monoxide gas at the
sensor. Carbon monoxide gas may be
present in other areas.
WARNING!
The Silence Feature is for your convenience
only and will not correct a CO problem.
Always check your home for a potential
problem after any alarm. Failure to do so can
result in injury or death.
concentrations under 30 ppm.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
The Cover of Your CO Alarm
HOW YOUR CO ALARM WORKS
General Information
A CO Alarm measures the CO levels in the air. It
will alarm if CO levels rise quickly (if the heat
exchanger on your furnace breaks, for
example), or if CO is consistently present (a
slow CO leak on a fuel-burning appliance).
This carbon monoxide alarm features a
permanently installed sensor, three colored
indicator lights, and an 85 dB alarm horn. It
also has a silence feature to temporarily quiet
the alarm horn.
1
2
Test/Silence Button:
BATTERY Light
(Dual Color —
Green or Yellow)
3
4
5
SERVICE Light (Yellow)
ALARM Light (Red)
(Behind Cover) Alarm Horn: 85db
audible alarm for test, alarm, and unit
malfunction warning.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
WHAT THE LIGHTS AND ALARM TONES MEAN
WELCOME CHIRP.
DURING TESTING -
GOOD BATTERY
CO ALARM
REQUIRES SERVICE
Horn chirps and battery light
blinks green once when battery
is first connected.
The SERVICE light flashes
YELLOW and the horn “chirps”
three times every 30 seconds.
CO Alarm needs to be serviced
or replaced. See Chapter 4 for
details.
When you press the Test/
Silence button, all three lights
will flash briefly, and the horn
will sound.
ALARM RECEIVING
BATTERY POWER
If the battery is GOOD,
the BATTERY light flashes
GREEN.
CO ALARM IS IN ALARM.
DURING TESTING -
LOW/WEAK BATTERY
BATTERY light flashes GREEN
twice a minute. Horn is silent.
LOW BATTERY WARNING.
Sensor has detected enough
CO to trigger an alarm. ALARM
light flashes RED rapidly and
horn sounds loudly. See
When you press the Test/
Silence button, all three lights
will flash briefly, but the horn
may stay silent.
Chapter 3 for details on how
to respond to an alarm.
The BATTERY light turns
YELLOW. It flashes and the
horn “chirps” twice a minute.
This warning should last for up
to 30 days, but you should
replace the battery as soon as
possible. See Chapter 4 for
details.
“ALARM-MOVE
TO FRESH AIR”
During an alarm, move
everyone to a source of fresh
air. Do NOT move the CO
Alarm!
If the battery is WEAK, the
BATTERY light flashes
YELLOW.
IMPORTANT! Replace a weak
battery immediately!
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty: 5-year limited warranty.
CO ALARM SPECIFICATIONS
Standards: Underwriters Laboratories Inc.
Single and Multiple Station carbon monoxide
alarms UL2034.
Gas Detection at Typical Temperature and
Humidity Ranges: The CO Alarm is not
formulated to detect CO levels below 30 ppm
typically. UL tested for false alarm resistance to
Methane (500 ppm), Butane (300 ppm),
Heptane (500 ppm), Ethyl Acetate (200 ppm),
Isopropyl Alcohol (200 ppm) and Carbon
Dioxide (5000 ppm). Values measure gas and
vapor concentrations in parts per million.
According to Underwriters Laboratories Inc.
UL2034, Section 1-1.2: “Carbon monoxide
alarms covered by these requirements are
intended to respond to the presence of carbon
monoxide from sources such as, but not limited
to, exhaust from internal-combustion engines,
abnormal operation of fuel-fired appliances,
and fireplaces. CO alarms are intended to alarm
at carbon monoxide levels below those that
could cause a loss of ability to react to the
dangers of Carbon Monoxide exposure.” This
CO Alarm monitors the air, and is designed to
alarm before CO levels become life threatening.
This allows you precious time to leave the
house and correct the problem. This is only
possible if alarms are located, installed, and
maintained as described in this manual.
Required Alarm Levels: Before 10% COHb
exposure at levels of 30% to 70% Relative
Humidity (RH):
•
•
•
400 ppm CO between 4 and 15 minutes
150 ppm CO between 10 and 50 minutes
70 ppm CO between 60 and 240 minutes
The unit is designed not to alarm when
exposed to a constant level of 30 ppm
for 30 days.
Audible Alarm: 85dB minimum at 10 feet
Power: Powered by 9V battery. Green light
flashes about twice a minute when device is
receiving battery power.
During Alarm: CO Alarm horn sounds while the
red light flashes rapidly.
This CO alarm is designed to sound for up to
12 hours in alarm conditions, provided the
battery is fresh and installed correctly.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 2: Installation
In a Single-level Home:
WHERE TO INSTALL
CO ALARMS
•
Install at least one CO Alarm near or
within each separate sleeping area.
The Consumer Product Safety Commission
(CPSC) recommends the use of at least one
CO Alarm per household, located near the
sleeping area. For added protection, install
additional CO Alarms in each separate
bedroom, and on every level of your home.
•
For added protection, install an additional
CO Alarm at least 20 feet (6 meters) away
from the furnace or fuel burning heat
source.
In a Multi-level Home:
If your bedroom hallway is longer than 40 feet,
install a CO Alarm at BOTH ends of the hallway.
•
Install at least one CO Alarm near or
within each separate sleeping area.
•
For added protection, install at least one
CO Alarm on each level of the home. If
you have a basement, install that CO
Alarm at the top of the basement stairs.
•
For added protection, install an additional
CO Alarm at least 20 feet (6 meters) away
from the furnace or fuel burning heat
source.
BEDROOM
BEDROOM
KITCHEN
BEDROOM
GARAGE
HALL
LIVING ROOM
In a Mobile Home:
•
Install CO Alarms on inside walls ONLY.
BASEMENT
Uninsulated outside walls and roofs of
mobile homes often transfer heat and
cold from outdoors.
SUGGESTED AREAS FOR INSTALLING CO ALARMS
5
Download from Www.Somanuals.com. All Manuals Search And Download.
WHERE NOT TO INSTALL
YOUR CO ALARM
WARNING!
This CO Alarm is designed for use inside a
single-family home or apartment. It is not
meant to be used in common lobbies,
hallways, or basements of multi-family
buildings unless working CO Alarms are also
installed in each family living unit. CO
Alarms in common areas may not be heard
from inside individual family living units.
DO NOT locate this CO Alarm:
•
In garages, kitchens, furnace rooms,
or in any extremely dusty, dirty or
greasy areas.
•
Closer than 20 feet from a furnace or
other fuel burning heat source, or fuel
burning appliances like a water heater.
WARNING!
•
•
Within 5 feet of any cooking appliance.
This CO Alarm alone is not a suitable
substitute for complete detection systems in
places which house many people, like hotels
or dormitories, unless a CO Alarm is also
placed in each unit.
In extremely humid areas. This alarm
should be at least 10 feet from a bath
or shower, sauna, humidifier, vaporizer,
dishwasher, laundry room, utility room,
or other source of high humidity.
WARNING!
•
In areas where temperature is colder than
40˚F (4˚C) or hotter than 100˚F (38˚C).
These areas include unconditioned crawl
spaces, unfinished attics, uninsulated or
poorly insulated ceilings, porches, and
garages.
In turbulent air, like near ceiling fans,
heat vents, air conditioners, fresh air
returns, or open windows. Blowing air
may prevent CO from reaching the
sensors.
DO NOT use this CO Alarm in warehouses,
industrial or commercial buildings, special-
purpose non-residential buildings, RVs,
boats, or airplanes. This CO Alarm is
specifically designed for residential use,
and may not provide adequate protection in
non-residential applications.
•
•
In direct sunlight.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
HOW TO INSTALL YOUR CO ALARM
Read “Where To Install Your CO Alarm”
before starting. This CO Alarm can be used on
a tabletop or mounted on the wall. For tabletop
use, choose a table no taller than 36” (92 cm);
a fall from a high table could damage the
Alarm’s sensitive components.
Installing the 9V Battery
1. Slide the mounting
bracket/battery door
off the back of the CO
Alarm.
Before you start installation, find the pair of
self-adhesive labels included with this CO
alarm. On each label write in the phone number
of your emergency responder (like 911) and a
qualified appliance technician. Place one label
near the CO Alarm, and the other label in the
“fresh air” location you plan to go if the alarm
sounds.
2. Attach the 9V battery
(included) to the
battery connector
inside the battery
compartment. Make
sure the battery snaps
in securely, and
NOTE:
cannot be shaken
loose.
A qualified appliance technician is defined as
“a person, firm, corporation, or company that
either in person or through a representative, is
engaged in and responsible for the installation,
testing, servicing, or replacement of heating,
ventilation, air conditioning (HVAC) equipment,
combustion appliances and equipment, and/or
gas fireplaces or other decorative combustion
equipment.”
3. Place the battery and
connector back inside
the battery
compartment.
IMPORTANT!
For your safety, the CO Alarm will not close until
a 9V battery is installed.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
For Tabletop Use
To Mount On The Wall
1. Close the battery
compartment by
Tools you will need: pencil, drill with 3/16” or
5mm drill bit, flathead screwdriver, hammer.
sliding the mounting
bracket/battery door
back onto the back of
the CO Alarm.
1. Choose a location on the wall. Do not install
the alarm closer than 4” from where the wall
meets the ceiling.
2. Hold the mounting
bracket against the wall,
and make a mark inside
each keyhole where you
will drill your mounting
hole.
2. Test the CO Alarm as described below.
3. Set the CO Alarm in plain view on a table
where it will not be blocked by any
obstructions.Table height should not exceed
36” (92 cm).
3. Use a 3/16” drill bit to drill through the marks
you made for the mounting holes.
IMPORTANT!
Put the CO Alarm where children and pets
cannot reach it.
4. Insert the plastic screw anchors into the
mounting holes until they are flush with the
wall. If necessary, tap them gently with a
hammer.
To Test this CO Alarm:
Push and hold the Test/Silence button on the
cover until you hear a “chirp.” The “chirp” marks
the start of the self-test sequence.
5. Line up the mounting
bracket up with the
screw anchors, and
screw the bracket onto
the wall.
•
First, the yellow and green lights will
flash briefly—this is normal.
•
Next, the alarm horn will sound: 4 beeps,
a pause, then 4 beeps. The red light will
flash quickly.
6. Slide the CO Alarm
onto the mounting bracket until you feel it
click into place.
The alarm sequence should last 5-6 seconds.
If it does not alarm, make sure the battery is
correctly installed, and test it again. If the unit still
does not alarm, replace it immediately.
7. Test the CO Alarm as described in “To Test
this CO Alarm.”
8
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 3: If Your CO Alarm Alarms
immediately. Note any combustion
WARNING!
equipment not inspected by the technician,
and consult the manufacturers’ instructions,
or contact the manufacturers directly, for
more information about CO safety and this
equipment. Make sure that motor vehicles
are not, and have not, been operating in an
attached garage or adjacent to the residence.
Write down the number of a qualified
Actuation of your CO alarm indicates the
presence of carbon monoxide (CO) which
can kill you. In other words, when your CO
Alarm alarms, you must not ignore it!
If the Alarm Signal Sounds:
1. Operate the Test/Silence button.
appliance technician here:
_______________________________________
2. Call your emergency services, fire
department or 911. Write down the number
of your local emergency service here:
“ALARM-MOVE
TO FRESH AIR”
If you hear the alarm
horn and the red light
is flashing, move
3. Immediately move to fresh air—outdoors or
by an open door or window. Do a head
count to check that all persons are
accounted for. Do not re-enter the premises,
or move away from the open door or
window until the emergency services
responder has arrived, the premises have
been aired out, and your CO alarm remains
in its normal condition.
everyone to a source
of fresh air. DO NOT
move the CO Alarm!
Finding the Source of CO
After an Alarm
4. After following steps 1-3, if your CO alarm
reactivates within a 24-hour period, repeat
steps 1-3 and call a qualified appliance
technician to investigate for sources of CO
from fuel-burning equipment and appliances,
and inspect for proper operation of this
equipment. If problems are identified during
this inspection have the equipment serviced
Because CO may dissipate by the time an
investigator arrives, it may be difficult to locate
the source of CO. See Chapter 5 “What You
Must Know About CO.” BRK Brands, Inc.
shall not be obligated to pay for any carbon
monoxide investigation or service call.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
While the alarm is silenced:
Using the Silence Feature
If the CO Alarm...
remains silent after you pressed the Test/
Silence button...
WARNING!
NEVER remove the batteries from your
CO Alarm to silence the horn. Use the
silence feature. Removing the batteries
removes your protection! See previous page
for details on responding to an alarm.
This means...
CO levels are dropping.
The silence feature is intended to temporarily
silence your CO Alarm’s alarm horn while you
correct the problem—it will not correct a CO
problem. While the alarm is silenced, it will
continue to monitor the air for CO.
If the CO Alarm...
goes back into alarm 4 minutes after you
pressed the Test/Silence button...
This means...
When CO reaches the alarm level, the Alarm
will sound— repeating horn pattern:
4 beeps, a pause, 4 beeps, etc. Press and hold
the Test/Silence button until the horn is silent.
The initial Silence cycle will last approximately
4 minutes.
CO levels present indicate a potentially
dangerous situation.
NOTE:
After initial 4-minute Silence cycle, the CO
Alarm re-evaluates present CO levels and
responds accordingly. If CO levels remain
potentially dangerous—or start rising higher—
the horn will start sounding again.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 4: Testing and Maintenance
If the alarm does not test properly:
WEEKLY TESTING
1. Make sure the battery is installed correctly.
2. Be sure the alarm is clean and dust-free.
WARNING!
DO NOT stand close to the alarm when the
horn is sounding. Exposure at close range
may be harmful to your hearing. When
testing, step away when horn starts
sounding.
3. Install a fresh 9V alkaline or lithium battery*
and test the alarm again.
If the CO Alarm is not working properly, refer to
the “Limited Warranty” at the end of this
manual.
Push and hold the Test/Silence button on the
cover until you hear a “chirp.” The “chirp”
marks the start of the self-test sequence.
CAUTION!
If there is still a problem, do not try to fix the
alarm yourself—this will void your warranty!
Install a new CO Alarm immediately. CO
Alarms under warranty can be returned to
BRK Brands, Inc. for replacement (see
Limited Warranty for details).
•
First, the BATTERY (green) and
SERVICE (yellow) lights will flash briefly—
this is normal.
Next, the alarm horn will sound: 4 beeps,
a pause, then 4 beeps. The ALARM (red)
light will flash quickly.
•
WARNING!
The alarm sequence should last 5-6 seconds.
If it does not alarm, make sure the battery is
correctly installed, and test it again. If the unit
still does not alarm, replace it immediately.
The Test/Silence button is the only proper
way to test the CO Alarm. NEVER use
vehicle exhaust! Exhaust may cause
permanent damage and voids your warranty.
NOTE:
When you press and hold the Test/Silence
button, if the battery is low or weak, the
BATTERY light will flash YELLOW. Even if the
horn sounds, you should replace a low or weak
battery immediately for optimum performance.
*For a list of acceptable replacement batteries,
see “Regular Maintenance.”
11
Download from Www.Somanuals.com. All Manuals Search And Download.
REGULAR MAINTENANCE
IMPORTANT!
Use only the alkaline or lithium replacement
batteries listed. The unit may not operate
properly with other batteries. Never use
rechargeable batteries since they may not
provide a constant charge.
To keep the CO Alarm in good working order:
•
Test it every week using the Test/Silence
button.
•
Vacuum the CO Alarm cover at least
twice a year, using the soft brush
attachment. Test the Alarm again after
vacuuming.
CAUTION!
DO NOT spray cleaning chemicals or insect
sprays directly on or near the CO Alarm. DO
NOT paint over the CO Alarm. Doing so may
permanently damage the CO Alarm.
•
Replace the battery when the CO Alarm
“chirps” and the yellow light blinks twice
a minute (the low battery warning).
IMPORTANT!
NOTE:
Household cleaners, aerosol chemicals, and
other contaminants can affect the sensor. When
using any of these materials near the alarm,
make sure the room is well ventilated.
The low battery warning should last for 30
days, but you should replace the battery
immediately to continue your protection.
Choosing a replacement battery:
This unit requires one standard 9V alkaline
battery. The following alkaline batteries are
acceptable as replacements: Duracell
#MN1604. You can also use an Ultralife 9 volt
lithium battery #U9VL for longer service life
between battery changes. These replacement
batteries are commonly available at local retail
stores.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 5: What You Need To Know About CO
What is CO?
CAUTION!
Some individuals are more sensitive to CO
than others, including people with cardiac or
respiratory problems, infants, unborn
babies, pregnant mothers, or elderly people
can be more quickly and severely affected
by CO. Members of sensitive populations
should consult their doctors for advice on
taking additional precautions.
CO is an invisible, odorless, tasteless gas
produced when fossil fuels do not burn
completely, or are exposed to heat (usually fire).
Electrical appliances typically do not
produce CO.
These fuels include: Wood, coal, charcoal, oil,
natural gas, gasoline, kerosene, and propane.
Common appliances are often sources of CO. If
they are not properly maintained, are improperly
ventilated, or malfunction, CO levels can rise
quickly. CO is a real danger now that homes are
more energy efficient. “Air-tight” homes with
added insulation, sealed windows, and other
weatherproofing can “trap” CO inside.
Finding the Source of CO
After an Alarm
Carbon monoxide is an odorless, invisible gas,
which often makes it difficult to locate the
source of CO after an alarm. These are a few of
the factors that can make it difficult to locate
sources of CO:
Symptoms of CO Poisoning
These symptoms are related to CO
POISONING and should be discussed with
ALL household members.
•
House well ventilated before the
investigator arrives.
Problem caused by “backdrafting.”
Transient CO problem caused by
special circumstances.
•
•
Mild Exposure Slight headache, nausea,
vomiting, fatigue (“flu-like” symptoms).
Medium Exposure Throbbing headache,
drowsiness, confusion, fast heart rate.
Extreme Exposure Convulsions,
unconsciousness, heart and lung failure.
Exposure to Carbon Monoxide can cause brain
damage, death.
BRK Brands, Inc. shall not be obligated to
pay for any carbon monoxide investigation
or service call.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
The following conditions can result in
transient CO situations:
Potential Sources Of CO In The Home
1. Excessive spillage or reverse venting of fuel
appliances caused by outdoor conditions
such as:
•
Wind direction and/or velocity, including
high, gusty winds. Heavy air in the vent
pipes (cold/humid air with extended
periods between cycles).
•
•
•
Negative pressure differential resulting
from the use of exhaust fans.
Several appliances running at the same
time competing for limited fresh air.
Vent pipe connections vibrating loose
from clothes dryers, furnaces, or water
heaters.
Fuel-burning appliances like: portable heater,
gas or wood burning fireplace, gas kitchen
range or cooktop, gas clothes dryer.
•
Obstructions in or unconventional vent
pipe designs which can amplify the
above situations.
Damaged or insufficient venting: corroded or
disconnected water heater vent pipe, leaking
chimney pipe or flue, or cracked heat
exchanger, blocked or clogged chimney
opening.
2. Extended operation of unvented fuel
burning devices (range, oven, fireplace).
3. Temperature inversions, which can trap
exhaust close to the ground.
Improper use of appliance/device: operating
a barbecue grill or vehicle in an enclosed area
(like a garage or screened porch).
4. Car idling in an open or closed attached
garage, or near a home.
These conditions are dangerous because they
can trap exhaust in your home. Since these
conditions can come and go, they are also hard
to recreate during a CO investigation.
Transient CO Problems: “transient” or on-
again-off-again CO problems can be caused by
outdoor conditions and other special
circumstances.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
present. Keep the blower door on the fur-
nace closed. Use vents or fans when they
are available on all fuel-burning appli-
ances. Make sure appliances are vented
to the outside. Do not grill or barbecue
indoors, or in garages or on screen
porches.
Check for exhaust backflow from CO
sources. Check the draft hood on an
operating furnace for a backdraft. Look
for cracks on furnace heat exchangers.
Check the house or garage on the other
side of shared wall.
Keep windows and doors open slightly.
If you suspect that CO is escaping into
your home, open a window or a door.
Opening windows and doors can signifi-
cantly decrease CO levels.
How Can I Protect My Family?
A CO Alarm is an excellent means of protection.
It monitors the air and sounds a loud alarm
before carbon monoxide levels become
threatening for average, healthy adults.
A CO Alarm is not a substitute for proper
maintenance of home appliances.
•
•
To help prevent CO problems and reduce the
risk of CO poisoning:
•
Clean chimneys and flues yearly. Keep
them free of debris, leaves, and nests for
proper air flow. Also, have a professional
check for rust and corrosion, cracks, or
separations. These conditions can pre-
vent proper air movement and cause
backdrafting. Never “cap” or cover a
chimney in any way that would block air
flow.
•
•
In addition, familiarize yourself with all
enclosed materials. Read this manual in its
entirety, and make sure you understand
what to do if your CO Alarm alarms.
•
•
Test and maintain all fuel-burning equip-
ment annually. Many local gas or oil com-
panies and HVAC companies offer
appliance inspections for a nominal fee.
Make regular visual inspections of all
fuel-burning appliances. Check appli-
ances for excessive rust and scaling.
Also check the flame on the burner and
pilot lights. The flame should be blue. A
yellow flame means fuel is not being
burned completely and CO may be
15
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 6: Underwriters Laboratories Inc. UL2034
What Levels of CO Cause an Alarm?
IMPORTANT!
Underwriters Laboratories Inc. UL2034 defines
three specific alarm points by which all
residential CO Alarms must alarm. They are
measured in parts per million (ppm) of CO over
time (in minutes).
This CO Alarm measures exposure to CO over
time. It alarms if CO levels are extremely high in
a short period of time, or if CO levels reach a
certain minimum over a long period of time. The
CO Alarm generally sounds an alarm before the
onset of symptoms in average, healthy adults.
UL2034 Required Alarm Points:
Why is this important? Because you need to be
warned of a potential CO problem while you
can still react in time. In many reported cases of
CO exposure, victims may be aware that they
are not feeling well, but become disoriented
and can no longer react well enough to exit the
building or get help. Also, young children and
pets may be the first affected. The average
healthy adult might not feel any symptoms
when the CO Alarm alarms. However, people
with cardiac or respiratory problems, infants,
unborn babies, pregnant mothers, or elderly
people can be more quickly and severely
affected by CO. If you experience even mild
symptoms of CO poisoning, consult your
doctor immediately!
•
•
•
If the alarm is exposed to 400 ppm
of CO, IT MUST ALARM BETWEEN
4 and 15 MINUTES
If the alarm is exposed to 150 ppm
of CO, IT MUST ALARM BETWEEN
10 and 50 MINUTES.
If the alarm is exposed to 70 ppm
of CO, IT MUST ALARM BETWEEN
60 and 240 MINUTES.
IMPORTANT!
CO Alarms are designed to alarm before there
is an immediate life threat. Since you cannot
see or smell CO, never assume it’s not present.
•
An exposure to 100 ppm of CO for 20
minutes may not affect average, healthy
adults, but after 4 hours the same level
may cause headaches.
•
An exposure to 400 ppm of CO may
cause headaches in average, healthy
adults after 35 minutes, but can cause
death after 2 hours.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 7: Troubleshooting Guide
Problem...
This means...
You should...
The BATTERY Light turns
YELLOW. It flashes and the
horn “chirps” twice a minute.
Low battery warning.
Install a new 9V alkaline or lithium battery*.
During testing, when you
press and hold the Test/
Silencebutton, theBATTERY
Light turns YELLOW.
Low battery
Install a new 9V alkaline or lithium battery*.
Horn chirps and yellow
service light blinks three
times every 30 seconds.
Unit needs to be
replaced.
Units under warranty should be returned to
manufacturer for replacement. See “Limited
Warranty” for details.
CO Alarm goes back into
alarm 4 minutes after you
press the Test/Silence
button.
CO levels indicate a
potentially dangerous
situation.
IF YOU ARE FEELING SYMPTOMS OF CO
POISONING, EVACUATE your home and call
911 or the Fire Department. If not, press the
Test/Silence button again and keep
ventilating your home.
CO Alarm alarms frequently The CO Alarm may be
even though no high levels of improperly located.
Relocate your alarm. If frequent alarms
continue, have home rechecked for potential
CO are revealed in an
investigation.
Refer to “Where to Install CO problems. You may be experiencing an
Your CO Alarm.”
intermittent CO problem.
*For a list of acceptable replacement batteries, see “Regular Maintenance.”
If you have any questions that cannot be answered by reading this manual, call our Consumer Affairs
Department at 1-800-323-9005, 7:30 a.m. - 5:00 p.m. (CT).
17
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 8: General Limitations Of CO Alarms
This CO Alarm is intended for residential use. It is not intended for use in industrial applications
where Occupational Safety and Health Administration (OSHA) requirements for carbon monoxide
alarms must be met.
CO Alarms will not work without power. This
alarm requires a 9V alkaline or lithium battery to
operate.
prevent alert persons from hearing the alarm horn.
This CO Alarm is not intended for people who are
hearing impaired.
CO Alarms are not a substitute for a smoke
alarm. Although fire is a source of carbon
monoxide, this CO Alarm does not sense smoke
or fire. This CO Alarm senses CO that may be
escaping unnoticed from malfunctioning furnaces,
appliances, or other sources. Early warning of fire
requires the installation of smoke alarms.
CO Alarms are not a substitute for life
insurance. Though these CO Alarms warn against
increasing CO levels, BRK Brands, Inc. does not
warrant or imply in any way that they will protect
lives from CO poisoning. Homeowners and renters
must still insure their lives.
CO Alarms have a limited life. Although the
CO Alarm and all of its parts have passed many
stringent tests and are designed to be as reliable
as possible, any of these parts could fail at any
time. Therefore, you must test your CO Alarm
weekly.
This CO Alarm will not sense carbon monoxide
that does not reach the sensor. This CO Alarm
will only sense CO at the sensor. CO may be
present in other areas. Doors or other obstructions
may affect the rate at which CO reaches the CO
Alarm. For this reason, we recommend if bedroom
doors are usually closed at night, you install a CO
Alarm in each bedroom and in the hallway
between them.
CO Alarms may not sense CO on another level
of the home. For example, a CO Alarm on the
second level, near the bedrooms, may not sense
CO in the basement. For this reason, one CO
Alarm may not give adequate warning. Complete
coverage is recommended. Place CO Alarms on
each level of the home.
CO Alarms may not be heard. The alarm horn
loudness meets or exceeds current UL standards.
However, if the CO Alarm is installed outside the
bedroom, it may not wake up a sound sleeper or
one who has recently used drugs or has been
drinking alcoholic beverages. This is especially
true if the door is closed or only partly open. Even
persons who are awake may not hear the alarm
horn if the sound is blocked by distance or closed
doors. Noise from traffic, stereo, radio, television,
air conditioner, or other appliances may also
CO Alarms are not foolproof. Like all other
electronic devices, CO Alarms have limitations.
They can only detect CO that reaches their
sensors. They may not give early warning to rising
CO levels if the CO is coming from a remote part
of the home, away from the CO Alarm.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
BRK Brands, Inc. shall not be liable for any
incidental or consequential damages caused by
the breach of any express or implied warranty.
Except to the extent prohibited by applicable law,
any implied warranty of merchantability or fitness
for a particular purpose is limited in duration for
five years. Some states, provinces, or jurisdictions
do not allow the exclusion or limitation of
incidental or consequential damages or limitations
on how long an implied warranty lasts, so the
above limitations or exclusions may not apply to
you. This warranty gives you specific legal rights,
and you may also have other rights that vary from
state to state, or province to province.
Limited Warranty
Coverage: BRK Brands, Inc. warrants its
enclosed carbon monoxide alarm to be free from
defects in materials and workmanship under
normal use for a period of five years from the date
of purchase. During the first year after the date of
purchase, BRK Brands, Inc. will replace any
defective carbon monoxide alarm without charge.
During the next four years, BRK Brands, Inc. will
replace any defective carbon monoxide alarm at a
charge to you not to exceed BRK Brands, Inc.’s
cost. This is your exclusive warranty.
This warranty is valid for the original retail
purchaser from the date of initial retail purchase
and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain
warranty performance. If this carbon monoxide
alarm is installed by a contractor, this warranty will
be valid for the homeowner (or the first
Service: Units under warranty and in need of
repair should be returned, shipping prepaid, to
BRK Brands, Inc., Attn.: Consumer Affairs,
3920 Enterprise Court, Aurora, IL 60504-8132.
homeowner after installation) from the date of
initial purchase by the contractor and is not
transferable. Dealers, service centers, or retail
stores selling this product do not have the right to
alter, modify or any way change the terms and
conditions of this warranty.
For your records, please record:
Date Purchased:
Where Purchased:
This warranty does not cover normal wear of parts
or damage resulting from any of the following:
negligent use or misuse of the product, use on
improper voltage or current or use contrary to the
operating instructions, disassembly, repair or
alteration by anyone other than BRK Brands, Inc.
Further, the warranty does not cover acts of God,
such as fire, flood, hurricanes and tornadoes.
®
BRK Electronics is a
registered trademark of
BRK Brands, Inc.