Beko Air Conditioner LG BKE 6450 D LG BKE 6500 D User Manual |
Room Air Conditioner
MANUAL
OWNER'S
Models :
LG-BKE 6450 D - LG-BKE 6500 D - LG-BKE 6600 D
LG-BKE 6700 D - LG-BKE 6800 D
Prior to installation, this air-conditioning
unit must be submitted for approval by the
utility service which provides electricity
(EN 6055-3 Norm).
IMP OR TANT
P leas e read this owner's manual carefully and thoroughly
before ins talling and operating your room air conditioner.
P leas e retain this owner's manual for future reference after
reading it thoroughly.
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
n
classified by the following indications.
This symbol indicates the possibility of death or serious injury.
WARNING
This symbol indicates the possibility of injury or damage to properties only.
CAUTION
Meanings of symbols used in this manual are as shown below.
n
Be sure not to do.
Be sure to follow the instruction.
WARNING
n Installation
Plug in the power plug properly.
Do not damage or use an unspecified power
cord.
• Otherwise, it will cause electric shock or fire due to
heat generation or electric shock.
• It will cause electric shock or fire.
• In the supply cord is damaged, it mut be replaced by
the manufacturer or its service agent or a similarly
quallfied person in order to avoid a hazard. (Y
Attachment)
Do not modify power cord length or share the
outlet with other appliances.
Always perform grounding work.
• It will cause electric shock or fire due to heat
generation.
• No grounding may cause electric shock.
Always install air leakage breaker and a
dedicated switching board.
Do not use the socket if it is loose or
damaged.
• No installation may cause fire and electric shock
accident.
• It may cause fire and electric shock.
Keep firearms away.
• It may cause fire.
Owner’s Manual
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
n Operation
Do not operate or stop the unit by inserting or
pulling out the power plug.
Do not allow water to run into electric parts.
• It will cause electric shock or fire due to heat
generation.
• It may cause failure of machine or electric shock.
Do not operate with wet hands or in damp
environment.
Do not direct airflow at room occupants only.
• It may cause electric shock.
• This could damage your health.
Unplug the unit if strange sounds, smell, or
smoke comes from it.
Do not open the entrance during operation.
• It may cause electric shock.
• It may cause fire and electric shock accident.
Do not use the power cord close to the
heating tools.
Do not use the power cord near flammable
gas or combustibles, such as gasoline,
benzene, thinner, etc.
• It may cause fire and electric shock.
• It may cause an explosion or fire.
Ventilate before operating air conditioner
when gas goes out.
Do not disassemble or modify products
randomly.
• It may cause explosion, fire and, burn.
• It may cause failure and electric shock.
CAUTION
n Installation
Ensure that an installation console of the
outdoor appliance is not damaged due to the
use for a long time.
Use caution when unpacking and installing.
Sharp edges could cause injury.
• If leaving appliance damaged, there is concern of
damage due to the falling of product.
4
Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
n Operation
Never touch the metal parts of the unit when
removing the filter.
Do not clean the air conditioner with water.
• They are sharp and may cause injury.
• Water may enter the unit and degrade the insulation. It
may cause an electric shock.
Ventilate well when used together with a
stove, etc.
When cleaning the unit, first make sure the power and
breaker are turned off.
• An oxygen shortage may occur.
• Since the fan rotates at high speed during operation, it
may cause injury.
Do not put a pet or house plant where it will be
exposed to direct air flow.
Do not use appliance for special purpose such
as animals or vegetables, precision machine, or
conservation of art articles.
• This could injure the pet or plant.
• It may cause damage of animals or vegetables or loss
of property.
Stop operation and close the window in storm
or hurricane.
Hold the plug by the head of the power plug
when taking it out.
• Operation with windows opened may cause wetting of
indoor and soaking of household furniture.
• It may cause electric shock and damage.
Turn off the main power switch when not
using it for a long time.
Do not place obstacles around the absorption
inlet or instead of blowing-out inlet.
• It may cause failure of product or fire.
• It may cause failure of appliance or accident.
Always insert the filters securely. Clean it once
every two weeks.
Do not use strong detergent such as wax or
thinner but use a soft cloth.
• Operation without filters may cause failure.
• Appearance may be deteriorated due to change of
product color or scratching of its surface.
Do not place heavy object on the power cord
and take care so that the cord should not be
pressed.
Do not drink water drained from air
conditioner.
• There is danger of fire or electric shock.
• It contains contaminants and will make you sick.
If water enters the product, turn the power
switch of the main body of appliance off.
After taking the power-plug out from the
socket, contact with the service center.
Owner’s Manual
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Prior to operation
Prior to operation
Preparing for operation
1. Contact an installation specialist for installation.
2. Plug in the power plug properly.
3. Use a dedicated circuit.
4. Do not use an extension cord.
5. Do not start/stop operation by plugging/unplugging the power cord.
6. If the cord/plug is damaged, replace it with only an authorized replacement part.
Usage
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices,
food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at
a very high speed during operation. There is a possibility of injury if the unit’s power is accidentally
triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
Symbols Used in this Manual
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the
air conditioner.
NOTICE
This symbol indicates special notes.
6
Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Operating Instructions
Remote Controller
Remove the battery cover by pulling it according to
the arrow direction.
Insert new batteries making sure that the (+) and (-)
of battery are installed correctly.
Reattach the cover by sliding it back into position.
NOTICE
: Use 2 AAA(1.5volt) batteries.
Do not use rechargeable batteries.
Storage and Tips For Using the Remote Control
• The remote control may be stored by mounting it on a
wall.
• To operate the room air conditioner, aim the remote
control at the signal receptor.
Signal Receptor
Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps
On/Off
: Lights up during the system operation.
Sleep Mode
Timer
: Lights up during Sleep Mode Auto operation.
: Lights up during Timer operation.
Lights up during Sleep Mode Auto operation.
Defrost Mode
: Lights up during Defrost Mode or Hot
Start operation (Heat pump model only)
: Lights up during outdoor unit operation.
(Cooling model only)
OUT
DOOR
OUTDOOR UNIT
OPERATION
Signal
ON
INDOOR UNIT :Lights up during indoor unit operation.(Optional)
OPERATION
receptor
Operation indication lamps
: Indicates the setting temperature
(Plasma model only)
88
PLASMA
Plasma
: Lights up during plasma operation (Plasma model only)
Owner’s Manual
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Remote Control Operation
The remote control transmits the signals to the system.
START/STOP BUTTON
Operation starts when this button is pressed
and stops when the button is pressed again.
1
Signal transmitter
OPERATION MODE SELECTION BUTTON
2
3
Used to select the operation mode.
ROOM TEMPERATURE SETTING
BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high and CHAOS.
4
5
JET COOL
Used to start or stop the speed
cooling. (Speed cooling operates
super high fan speed in cooling mode.)
5
6
1
3
CHAOS SWING BUTTON
6
7
Used to stop or start louver movement and
set the desired up/down airflow direction.
4
ON/OFF TIMER BUTTONS (OPTIONAL)
Used to set the time of starting and stopping
operation. (See page 17)
TIME SETTING BUTTONS
Used to adjust the time. (See page 17)
TIMER SET/CANCEL BUTTON
Used to set the timer when the desired time is
obtained and to cancel the Timer operation.
(See page 17)
10
2
7
CANCEL
9
ON
OFF
SET
AUTO CLEAN
8
9
12
11
8
17
14
13
15
16
SLEEP MODE AUTO BUTTON
10 Used to set Sleep Mode Auto operation.
(See page 17)
AIR CIRCULATION BUTTON
11 Used to circulate the room air without cooling
or heating. (See page 19)
Flip-up door
(opened)
ROOM TEMPERATURE CHECKING
12
BUTTON
Used to check the room temperature.
Operation Mode
PLASMA(OPTIONAL)
13
Used to start or stop the plasma-purification
Cooling Operation
function. (See page 15)
HORIZONTAL AIRFLOW DIRECTION
Auto Operation or Auto Changeover
Healthy Dehumidification Operation
14
CONTROL BUTTON
(NOT ON ALL MODELS)
Used to set the desired horizontal airflow
direction. (See page 18)
RESET BUTTON
15
Used prior to resetting time or after replacing
Heating Operation
batteries.
2nd F Button
•
Cooling Model( ), Heat Pump Model(
)
16
Used prior to using modes printed in blue at
the bottom of buttons. (See page 16)
AUTO CLEAN(OPTIONAL)
Used to set Auto Clean mode.
17
8
Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Cooling Operation
Press the Start/Stop button.
The unit will respond with
a beep.
1
Open the door on the remote control. To select Cooling
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
2
Cooling
Auto
Healthy
Heating
Dehumidification
(Heat pump model only)
Close the door on the remote control. Set the temperature
lower than the room temperature. The temperature can be
set within a range of 18°C~30°C in 1°C increments.
3
4
ON
To raise the temperature
To lower the temperature
Set the fan speed again with the door
of the remote control still closed. You
can select the fan speed in four steps-
low, medium, high and CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
Natural wind by the CHAOS logic
o For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to
CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan
speed according to the CHAOS logic.
Owner’s Manual
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Auto Operation (Optional)
Press the Start/Stop button.
The unit will respond with
a beep.
1
Open the door on the remote control. To select Auto
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
2
Cooling
Auto
Healthy
Heating
Dehumidification
(Heat pump model only)
The temperature and fan speed are automatically set by the
electronic controls based on the actual room temperature. If
you want to change the set temperature, press the Room
Temperature Setting buttons. The cooler or warmer you feel,
the more times (up to two times) you should press the button.
The set temperature will be changed automatically.
ON
3
To raise the temperature
To lower the temperature
For this operation A 1 appears on the display
(Cooling plasma model only)
During Auto Operation:
o You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
o If the system is not operating as desired, manually switch to another mode. The system will not
automatically switch from the cooling mode to the heating mode, or from heating mode to cooling
mode, it must be done by manually resetting.
oDuring Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and
down automatically. If you want to stop auto-swing, press the chaos swing button again.
10 Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Auto Changeover Operation(Optional)
Press the Start/Stop button.
The unit will respond with
a beep.
1
Open the door on the remote control. To select Auto Changeover
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is shifted in the
direction of the arrow.
2
Auto
changeover
Cooling
Healthy
Heating
Dehumidification
(Heat pump model only)
Close the door on the remote control. Set the temperature
lower than the room temperature. The temperature can be
set within a range of 18°C~30°C in 1°C increments.
3
4
ON
To raise the temperature
To lower the temperature
Set the fan speed again with the door
of the remote control still closed. You
can select the fan speed in four steps-
low, medium, high and CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
During Auto changeover Operation:
The air conditioner changes the operation mode automatically to keep indoor temperature. When room
temperature vary over 2°C with respect to setting temperature, air conditioner keeps the room
temperature in 2°C with respect to setting temperature by auto changeover mode.
Owner’s Manual 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Healthy Dehumidification Operation
Press the Start/Stop button.
The unit will respond with
a beep.
1
2
Open the door on the remote control. To select Healthy
Dehumidification Operation, press the Operation Mode
Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
Cooling
Auto
Healthy
Heating
Dehumidification
(Heat pump model only)
Set the fan speed again with the door
of the remote control still closed. You
can select the fan speed in four steps-
low, medium, high, or CHAOS. Each
time the button is pressed, the fan
speed mode is shifted.
3
ON
Natural wind by the CHAOS logic
o For more fresh feeling than other fan speed, press the Indoor Fan
Speed Selector and set to CHAOS mode. In this mode, the wind
blows like natural breeze by automatically changing fan speed
according to the CHAOS logic.
During Healthy Dehumidification Operation:
o If you select the dehumidification mode on the operation selection button, the A/C starts to run the
dehumidification function. It automatically sets the room temp. and airflow volume to the best condition
for dehumidification, based on the sensed current room temp.
In this case, however, the setting temp. is not displayed in the remote control and you are not able to
control the room temp. either.
During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status which makes the room condition
healthy and comfortable even in the high humidity season.
o
12 Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Heating Operation(Heat pump model only)
Press the Start/Stop button.
The unit will respond with
a beep.
1
Open the door on the remote control. To select Heating
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
2
Cooling
Auto
Healthy
Heating
Dehumidification
(Heat pump model only)
Close the door on the remote control.
Set the temperature higher than the room temperature.
The temperature can be set within a range of 16°C~30°C in
1°C increments.
3
4
ON
To raise the temperature
To lower the temperature
Set the fan speed again with the door of the
remote control still closed. You can select
the fan speed in four steps–low, medium,
high and CHAOS. Each time the button is
pressed, the fan speed mode is shifted.
Natural wind by the CHAOS logic
o For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to
CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan
speed according to the CHAOS logic.
Owner’s Manual 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Jet Cool Operation
Press the Start/Stop button.
The unit will respond with
a beep.
1
2
3
Press the Jet Cool button to operate
the speed cooling mode and the unit
will operate in super high fan speed
on cooling mode for 30 minutes.
For this operation P0 appears on the
display. (Plasma model only)
To cancel the Jet Cool mode, press the Jet Cool button or
the fan speed button or the room temperature setting button
again and the unit will operate in high fan speed on cooling
mode.
or
or
NOTICE
o
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely
high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used
to cool the room temp. in the shortest time in a hot summer.
In heat pump mode or neuro fuzzy mode, however, the JET COOL function is not available.
o
In order to return to the normal cooling mode from the JET COOL mode, you just press
either the operation mode selection button, airflow volume selection or temp. setting button
or the JET COOL button again.
14 Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
PLASMA Purification Operation(Optional)
Press the Start/Stop button.
The unit will respond with a
beep.
1
Open the door on the remote control.
2
3
Press the PLASMA air purifying
operation ON/OFF button.
Operation will start when the button is
pressed and stop when the button is
pressed again.
Make sure the plasma led lights up.
Set the fan speed again with door of the remote control
closed. You can select the fan speed in four
steps-low, medium, high or CHAOS.
Each time the button is pressed, the fan
speed mode is shifted.
Z Air purifying operation (PLASMA) can be with
cooling, Heating or any other operations.
PLASMA Air Purifying Operation only
If you press the only PLASMA button, only
PLASMA air purifying operates.
Then, fan speed is low. You can select the fan
speed in four steps-low, medium, high or
CHAOS.
Each time the button (
speed mode is shifted.
) is pressed, the fan
Owner’s Manual 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
2nd F Operation
Press the Start/Stop button.
The unit will respond with
a beep.
1
Open the door of the remote control and press the 2nd
Function button to operate functions printed in blue at bottom
of buttons.
(Check the indication of 2nd function on remote control
display.)
2
These buttons operate the timer setting as follows:
CANCEL
SET
ON
OFF
CANCEL
ON
OFF
SET
AUTO CLEAN
2nd function goes off in a short time automatically or when
the button is pressed again.
3
For more details, refer to functions next page.
16 Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Additional features
Sleep Mode
To cancel the Sleep Mode, press the sleep
Mode Auto button several times until the star
Press the Sleep Mode Auto button to set the
time you want the unit to turn off automatically.
1
2
(
) disappears from the operation display.
The Timer is programmed in one-hour
increments by pressing the Sleep Mode Auto
button 1 to 7 times.
The sleep mode is available for 1 to 7 times. To
alter the time period in steps of 1 hour, press
the Sleep Mode Button while aiming at air
conditioner.
sleeping.
Make sure the Sleep Mode Auto LED lights up.
3
1
Setting the Time
Time can be set only when you have pressed
the Reset button. If you have just replaced the
batteries, the Reset button should be pressed
to reset the time.
Press the Time Setting buttons until the
desired time is set.
3
4
Press the Start/Stop button.
CANCEL
Press the Timer SET button.
2
SET
Press 2nd F button
and check if 2nd F icon is on.
NOTICE
Check the indicator for A.M. and
P.M.
Owner’s Manual 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Vertical Airflow Direction Control
The up/down airflow (Vertical Airflow) can be
adjusted by using the remote control.
NOTICE
ꢀ If you press the CHAOS swing button, at first 5 cycles,
the horizontal louver will swing up and down at maximum
angle. Then, the vertical airflow direction is changed
automatically based on the CHAOS algorithm to distribute
the air in the room evenly and at the same time to make
the human body feel most comportable, as if enjoying
a natural breeze.
Always use the remote control to adjust the
up/down airflow direction. Manually moving the
vertical airflow direction louver by hand, could
damage the air conditioner.
Press the Start/Stop button to start the unit.
1
2
o
Press Chaos Swing button and the louvers will
swing up and down. Press the Chaos Swing
button again to set the horizontal louver at the
desired airflow direction.
o
When the unit is shut off, the up/down airflow
direction louver will close the air outlet vent of the
system.
To adjust left/right(Horizontal Airflow)
direction
Caution : Ensure that the
unit is turned off before adjusting
the horizontal airflow direction
control. Carefully open vertical
louver to allow access to the
horizontal airflow direction.
Adjust the left/right airflow
direction by hand.
Auto-Clean
Whenever you press the Auto Clean button, Auto Clean Function will be reserved and
cancelled.
1
2
3
4
AUTO CLEAN
Auto Clean function works before and after cooling or dehumidification mode. For details,
refer to the below points.
When the unit is started after the reservation of Auto Clean ,the Cool Start function
operates and indoor Fan is started after 20 seconds.
When you press Start/Stop button to turn off the unit after the you have reserved Auto
Clean function, the air-conditioner circulates the indoor air in the Auto Clean mode with
no more Cooling or Dehumidification operation.
For Cooling only model, it lasts for 30 minutes for Heat pump model, for 16 minutes.
If you press the auto clean button again during the product operation, Auto Clean
function will be cancelled.
5
For this operation
C0
appears on the display. (Plasma model only)
NOTICE
o
This function is to remove unpleasant smells from mold and other bacteria in the air-conditioner, and
to remove humidity automatically during humidly summer, which supplies the indoor with purified air.
Horizontal Airflow Direction Control (Optional)
The left/right(Horizontal Airflow) can be adjusted by using the remote control.
Press the Start/Stop button to start the unit.
Open the door on the remote control. Press the Airflow Direction Start/Stop button
and the louvers will swing left and right. Press the Horizontal Airflow Direction
Control Button again to set the vertical louver at the desired airflow direction.
18 Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
Air Circulation Mode
Circulates the room air without cooling or heating.
Press the Start/Stop button. the unit will respond with a beep.
1
2
Open the door on the remote control. Press the Air Circulation button. Close the door on the
remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is
shifted from low to CHAOS and back to low again.
CHAOS Air
Fan speed is on low. Fan speed is on medium. Fan speed is on high.
NOTICE
o CHAOS Air economizes power consumption and prevents overcooling. The fan speed is
automatically changed from high to low or vice versa, depending on the ambient temperature.
Forced Operation
Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Power
button
Open the front
panel upward
Heat pump Model
Cooling Model
Room Temp. ≥ 24°C
Cooling
21°C ″ Room Temp. < 24°C
Room Temp. < 21°C
Heating
Operating mode
Indoor FAN Speed
Setting Temperature
Cooling
High
Healthy Dehumidification
High
High
23°C
High
24°C
22°C
22°C
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for about
3 seconds.
If you want to stop the operation, re-press the button.
For this operation
L
0
appears on the display. (Plasma model only)
Auto restart(Optional)
In case the power comes on again after a power failure, Auto Restarting Operation is the function to
operate procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
Additionally, in order to cancel auto restart operation press power button let it be pressed for about
6 seconds. To operate auto restart operation again, press power button for about 6 seconds as well.
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the value when the fan
speed is set to high, and the capacity will be lower at low or medium fan speed.
High fan speed is recommended when you wish to cool the room quickly.
Owner’s Manual 19
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance and Service
Maintenance and Service
CAUTION: Before performing any maintenance, turn off the main power to the system.
Indoor Unit
o
Never use any of the followings:
Grille, Case, and Remote Control
• Water hotter than 40°C
Could cause deformation and/or
discoloration.
o Turn the system off before cleaning. To
clean, wipe with a soft, dry cloth. Do not
use bleach or abrasives.
• Volatile substances
Could damage the surfaces of the air
conditioner.
NOTICE
Supply power must be disconnected
before cleaning the indoor unit.
P
o
w
d
e
r
G
a
e
i
n
s
o
l
Air inlet vent
Air outlet vent Air filters
(behind front panel)
Lift the front access panel and pull the filter tab
slightly forward to remove the filter.
Vertical louver Horizontal louver
1
AIR FILTERS
Clean the filter with a vacuum cleaner or
warm, soapy water.
• If dirt is conspicuous, wash with a
solution of detergent in lukewarm water.
• If hot water (40°C or more) is used, it
may be deformed.
The air filters behind the front grille should be
checked and cleaned once in every 2 weeks or
more often if neccessary.
2
After washing with water, dry well in the
shade.
3
4
Re-install the air filter.
NANO PLASMA FILTER, TRIPLE
DEODORIZING FILTER(OPTIONAL)
The PLASMA filter behind the air filters should be
checked and cleaned once in every 3 months or
more often if necessary.
After removing the air filters, pull slightly
forward to remove the NANO PLASMA filter.
1
2
Remove dust with vacuum cleaner or air.
(You should not try to wash with water).
3
4
Note the cuts of electric discharge lines.
Re-install the NANO PLASMA filter to the
original position.
TRIPLE DEODORIZING Filter
NANO PLASMA Filter
After removing the air filters, pull slightly
forward to remove the TRIPLE
DEODORIZING filter.
1
2
3
Dry in the sunlight for two hours.
Don’t touch this PLASMA Filter within 10
seconds after opening the inlet grille, it may
cause an electric shock.
Re-install the TRIPLE DEODORIZING filter to
the original position.
20 Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance and Service
Replacement of Purifying Filter(Optional)
• Recomended use period : About 2 years
Open front panel and remove air
filters.
Remove Triple deodorizing Filters.
2
3
1
Insert new Triple deodorizing Filters.
Air filter
2
3
Reinsert air filters and close front
panel.
4
Triple Deodorizing Filter
Outdoor Unit
The heat exchanger coils and panel vents of the outdoor
unit should be checked regularly. If clogged with dirt or
soot, the heat exchanger and panel
(Rear)
(Side)
vents may be professionally steam cleaned.
Air intake
vents
Piping
Drain Hose
NOTICE
Air outlet
vents
Dirty or clogged coils will reduce the
operating efficiency of the system and cause higher
operating costs.
Owner’s Manual 21
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance and Service
When the air conditioner is not going to be used for a long time.
When air conditioner is not going to be
When the air conditioner is to be used again.
used for a long time.
Clean the air filter and install it in the indoor
unit.
Operate the air conditioner on mode for 2 to
3 hours.
(Refer to page 20 for cleaning filters.)
• This will dry out the internal mechanisms.
Turn off the circuit breaker, and disconnect
the plug.
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
CAUTION
CAUTION
Turn off the circuit breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a fire.
Remove the batteries from the remote
control.
Operation Tips
Do not overcool the room.
Keep blinds or curtains
closed.
Keep the room temperature
uniform.
This is not good for the health
and wastes electricity.
Do not let direct sunshine enter
the room when the air
conditioner is in operation.
Adjust the vertical and
horizontal airflow direction to
ensure a uniform temperature
in the room.
Make sure that the doors
and windows are shut tight.
Clean the air filter regularly.
Ventilate the room
occasionally.
Blockages in the air filter
reduces the airflow and lowers
the cooling and dehumidifying
effects. Clean at least once in
every two weeks.
Since windows are kept closed,
it is a good idea to open them
and ventilate the room now and
then.
Avoid opening doors and
windows as much as possible
to keep the cool air in the room.
22 Room Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance and Service
Troubleshooting
Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or
service center.
Case
Explanation
See page
17
The air conditioner does not
operate.
• Have you made a mistake in timer operation?
• Has the fuse blown or has the circuit breaker
been tripped?
-
-
The room has a peculiar
odor.
• Check that this is not a damp smell exuded by
the walls, carpet, furniture, or cloth items in the
room.
It seems that condensation
is leaking from the air
conditioner.
• Condensation occurs when the airflow from
the air conditioner cools the warm room air.
-
-
Air conditioner does not
operate for about 3 minutes
when restarted.
• This is the protector of the mechanism.
• Wait about three minutes and operation will
begin.
Does not cool or heat
effectively.
• Is the air filter dirty? See air filter cleaning
instructions.
20
• Has the temperature been set incorrectly?
• Are the indoor unit's air inlet or outlet vents
obstructed?
9, 13
-
The air conditioner
operation is noisy.
• For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the
air conditioner unit.
• For a noise that sounds like the compressed
air releasing into atmosphere.
-
-This is the sound of the dehumidifying water
being processed inside the air conditioning
unit.
Remote control display is
faint, or no display at all.
• Are the batteries depleted?
• Are the batteries inserted in the opposite (+)
and (-) directions?
7
-
Crack sound is heard.
• This sound is generated by the
expansion/constriction of the front panel, etc.
due to changes of temperature.
Owner’s Manual 23
Download from Www.Somanuals.com. All Manuals Search And Download.
|