Prior to installation, this air-conditioning  
unit must be submitted for approval by the  
utility service which provides electricity  
(EN 6055-3 Norm).  
IMP OR TANT  
P leas e read this owner's manual carefully and thoroughly  
before ins talling and operating your room air conditioner.  
P leas e retain this owner's manual for future reference after  
reading it thoroughly.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
Safety Precautions  
To prevent injury to the user or other people and property damage, the following instructions  
must be followed.  
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is  
n
classified by the following indications.  
This symbol indicates the possibility of death or serious injury.  
WARNING  
This symbol indicates the possibility of injury or damage to properties only.  
CAUTION  
Meanings of symbols used in this manual are as shown below.  
n
Be sure not to do.  
Be sure to follow the instruction.  
WARNING  
n Installation  
Plug in the power plug properly.  
Do not damage or use an unspecified power  
cord.  
• Otherwise, it will cause electric shock or fire due to  
heat generation or electric shock.  
• It will cause electric shock or fire.  
• In the supply cord is damaged, it mut be replaced by  
the manufacturer or its service agent or a similarly  
quallfied person in order to avoid a hazard. (Y  
Attachment)  
Do not modify power cord length or share the  
outlet with other appliances.  
Always perform grounding work.  
• It will cause electric shock or fire due to heat  
generation.  
• No grounding may cause electric shock.  
Always install air leakage breaker and a  
dedicated switching board.  
Do not use the socket if it is loose or  
damaged.  
• No installation may cause fire and electric shock  
accident.  
• It may cause fire and electric shock.  
Keep firearms away.  
• It may cause fire.  
Owner’s Manual  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
n Operation  
Do not operate or stop the unit by inserting or  
pulling out the power plug.  
Do not allow water to run into electric parts.  
• It will cause electric shock or fire due to heat  
generation.  
• It may cause failure of machine or electric shock.  
Do not operate with wet hands or in damp  
environment.  
Do not direct airflow at room occupants only.  
• It may cause electric shock.  
• This could damage your health.  
Unplug the unit if strange sounds, smell, or  
smoke comes from it.  
Do not open the entrance during operation.  
• It may cause electric shock.  
• It may cause fire and electric shock accident.  
Do not use the power cord close to the  
heating tools.  
Do not use the power cord near flammable  
gas or combustibles, such as gasoline,  
benzene, thinner, etc.  
• It may cause fire and electric shock.  
• It may cause an explosion or fire.  
Ventilate before operating air conditioner  
when gas goes out.  
Do not disassemble or modify products  
randomly.  
• It may cause explosion, fire and, burn.  
• It may cause failure and electric shock.  
CAUTION  
n Installation  
Ensure that an installation console of the  
outdoor appliance is not damaged due to the  
use for a long time.  
Use caution when unpacking and installing.  
Sharp edges could cause injury.  
• If leaving appliance damaged, there is concern of  
damage due to the falling of product.  
4
Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
n Operation  
Never touch the metal parts of the unit when  
removing the filter.  
Do not clean the air conditioner with water.  
• They are sharp and may cause injury.  
• Water may enter the unit and degrade the insulation. It  
may cause an electric shock.  
Ventilate well when used together with a  
stove, etc.  
When cleaning the unit, first make sure the power and  
breaker are turned off.  
• An oxygen shortage may occur.  
• Since the fan rotates at high speed during operation, it  
may cause injury.  
Do not put a pet or house plant where it will be  
exposed to direct air flow.  
Do not use appliance for special purpose such  
as animals or vegetables, precision machine, or  
conservation of art articles.  
• This could injure the pet or plant.  
• It may cause damage of animals or vegetables or loss  
of property.  
Stop operation and close the window in storm  
or hurricane.  
Hold the plug by the head of the power plug  
when taking it out.  
• Operation with windows opened may cause wetting of  
indoor and soaking of household furniture.  
• It may cause electric shock and damage.  
Turn off the main power switch when not  
using it for a long time.  
Do not place obstacles around the absorption  
inlet or instead of blowing-out inlet.  
• It may cause failure of product or fire.  
• It may cause failure of appliance or accident.  
Always insert the filters securely. Clean it once  
every two weeks.  
Do not use strong detergent such as wax or  
thinner but use a soft cloth.  
• Operation without filters may cause failure.  
• Appearance may be deteriorated due to change of  
product color or scratching of its surface.  
Do not place heavy object on the power cord  
and take care so that the cord should not be  
pressed.  
Do not drink water drained from air  
conditioner.  
• There is danger of fire or electric shock.  
• It contains contaminants and will make you sick.  
If water enters the product, turn the power  
switch of the main body of appliance off.  
After taking the power-plug out from the  
socket, contact with the service center.  
Owner’s Manual  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Prior to operation  
Prior to operation  
Preparing for operation  
1. Contact an installation specialist for installation.  
2. Plug in the power plug properly.  
3. Use a dedicated circuit.  
4. Do not use an extension cord.  
5. Do not start/stop operation by plugging/unplugging the power cord.  
6. If the cord/plug is damaged, replace it with only an authorized replacement part.  
Usage  
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.  
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.  
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or  
other heating devices.  
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices,  
food, pets, plants, and art objects). Such usage could damage the items.  
Cleaning and maintenance  
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling  
sharp metal edges.  
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,  
leading to possible electric shock.  
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at  
a very high speed during operation. There is a possibility of injury if the unit’s power is accidentally  
triggered on while cleaning inner parts of the unit.  
Service  
For repair and maintenance, contact your authorized service dealer.  
Symbols Used in this Manual  
This symbol alerts you to the risk of electric shock.  
This symbol alerts you to hazards that could cause harm to the  
air conditioner.  
NOTICE  
This symbol indicates special notes.  
6
Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Operating Instructions  
Remote Controller  
Remove the battery cover by pulling it according to  
the arrow direction.  
Insert new batteries making sure that the (+) and (-)  
of battery are installed correctly.  
Reattach the cover by sliding it back into position.  
NOTICE  
: Use 2 AAA(1.5volt) batteries.  
Do not use rechargeable batteries.  
Storage and Tips For Using the Remote Control  
• The remote control may be stored by mounting it on a  
wall.  
• To operate the room air conditioner, aim the remote  
control at the signal receptor.  
Signal Receptor  
Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)  
Operation Indication Lamps  
On/Off  
: Lights up during the system operation.  
Sleep Mode  
Timer  
: Lights up during Sleep Mode Auto operation.  
: Lights up during Timer operation.  
Lights up during Sleep Mode Auto operation.  
Defrost Mode  
: Lights up during Defrost Mode or Hot  
Start operation (Heat pump model only)  
: Lights up during outdoor unit operation.  
(Cooling model only)  
OUT  
DOOR  
OUTDOOR UNIT  
OPERATION  
Signal  
ON  
INDOOR UNIT :Lights up during indoor unit operation.(Optional)  
OPERATION  
receptor  
Operation indication lamps  
: Indicates the setting temperature  
(Plasma model only)  
88  
PLASMA  
Plasma  
: Lights up during plasma operation (Plasma model only)  
Owner’s Manual  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Remote Control Operation  
The remote control transmits the signals to the system.  
START/STOP BUTTON  
Operation starts when this button is pressed  
and stops when the button is pressed again.  
1
Signal transmitter  
OPERATION MODE SELECTION BUTTON  
2
3
Used to select the operation mode.  
ROOM TEMPERATURE SETTING  
BUTTONS  
Used to select the room temperature.  
INDOOR FAN SPEED SELECTOR  
Used to select fan speed in four steps  
low, medium, high and CHAOS.  
4
5
JET COOL  
Used to start or stop the speed  
cooling. (Speed cooling operates  
super high fan speed in cooling mode.)  
5
6
1
3
CHAOS SWING BUTTON  
6
7
Used to stop or start louver movement and  
set the desired up/down airflow direction.  
4
ON/OFF TIMER BUTTONS (OPTIONAL)  
Used to set the time of starting and stopping  
operation. (See page 17)  
TIME SETTING BUTTONS  
Used to adjust the time. (See page 17)  
TIMER SET/CANCEL BUTTON  
Used to set the timer when the desired time is  
obtained and to cancel the Timer operation.  
(See page 17)  
10  
2
7
CANCEL  
9
ON  
OFF  
SET  
AUTO CLEAN  
8
9
12  
11  
8
17  
14  
13  
15  
16  
SLEEP MODE AUTO BUTTON  
10 Used to set Sleep Mode Auto operation.  
(See page 17)  
AIR CIRCULATION BUTTON  
11 Used to circulate the room air without cooling  
or heating. (See page 19)  
Flip-up door  
(opened)  
ROOM TEMPERATURE CHECKING  
12  
BUTTON  
Used to check the room temperature.  
Operation Mode  
PLASMA(OPTIONAL)  
13  
Used to start or stop the plasma-purification  
Cooling Operation  
function. (See page 15)  
HORIZONTAL AIRFLOW DIRECTION  
Auto Operation or Auto Changeover  
Healthy Dehumidification Operation  
14  
CONTROL BUTTON  
(NOT ON ALL MODELS)  
Used to set the desired horizontal airflow  
direction. (See page 18)  
RESET BUTTON  
15  
Used prior to resetting time or after replacing  
Heating Operation  
batteries.  
2nd F Button  
Cooling Model( ), Heat Pump Model(  
)
16  
Used prior to using modes printed in blue at  
the bottom of buttons. (See page 16)  
AUTO CLEAN(OPTIONAL)  
Used to set Auto Clean mode.  
17  
8
Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Cooling Operation  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
Open the door on the remote control. To select Cooling  
Operation, press the Operation Mode Selection button.  
Each time the button is pressed, the operation mode is  
shifted in the direction of the arrow.  
2
Cooling  
Auto  
Healthy  
Heating  
Dehumidification  
(Heat pump model only)  
Close the door on the remote control. Set the temperature  
lower than the room temperature. The temperature can be  
set within a range of 18°C~30°C in 1°C increments.  
3
4
ON  
To raise the temperature  
To lower the temperature  
Set the fan speed again with the door  
of the remote control still closed. You  
can select the fan speed in four steps-  
low, medium, high and CHAOS.  
Each time the button is pressed, the  
fan speed mode is shifted.  
Natural wind by the CHAOS logic  
o For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to  
CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan  
speed according to the CHAOS logic.  
Owner’s Manual  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Auto Operation (Optional)  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
Open the door on the remote control. To select Auto  
Operation, press the Operation Mode Selection button.  
Each time the button is pressed, the operation mode is  
shifted in the direction of the arrow.  
2
Cooling  
Auto  
Healthy  
Heating  
Dehumidification  
(Heat pump model only)  
The temperature and fan speed are automatically set by the  
electronic controls based on the actual room temperature. If  
you want to change the set temperature, press the Room  
Temperature Setting buttons. The cooler or warmer you feel,  
the more times (up to two times) you should press the button.  
The set temperature will be changed automatically.  
ON  
3
To raise the temperature  
To lower the temperature  
For this operation A 1 appears on the display  
(Cooling plasma model only)  
During Auto Operation:  
o You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.  
o If the system is not operating as desired, manually switch to another mode. The system will not  
automatically switch from the cooling mode to the heating mode, or from heating mode to cooling  
mode, it must be done by manually resetting.  
oDuring Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and  
down automatically. If you want to stop auto-swing, press the chaos swing button again.  
10 Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Auto Changeover Operation(Optional)  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
Open the door on the remote control. To select Auto Changeover  
Operation, press the Operation Mode Selection button.  
Each time the button is pressed, the operation mode is shifted in the  
direction of the arrow.  
2
Auto  
changeover  
Cooling  
Healthy  
Heating  
Dehumidification  
(Heat pump model only)  
Close the door on the remote control. Set the temperature  
lower than the room temperature. The temperature can be  
set within a range of 18°C~30°C in 1°C increments.  
3
4
ON  
To raise the temperature  
To lower the temperature  
Set the fan speed again with the door  
of the remote control still closed. You  
can select the fan speed in four steps-  
low, medium, high and CHAOS.  
Each time the button is pressed, the  
fan speed mode is shifted.  
During Auto changeover Operation:  
The air conditioner changes the operation mode automatically to keep indoor temperature. When room  
temperature vary over 2°C with respect to setting temperature, air conditioner keeps the room  
temperature in 2°C with respect to setting temperature by auto changeover mode.  
Owner’s Manual 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Healthy Dehumidification Operation  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
2
Open the door on the remote control. To select Healthy  
Dehumidification Operation, press the Operation Mode  
Selection button.  
Each time the button is pressed, the operation mode is  
shifted in the direction of the arrow.  
Cooling  
Auto  
Healthy  
Heating  
Dehumidification  
(Heat pump model only)  
Set the fan speed again with the door  
of the remote control still closed. You  
can select the fan speed in four steps-  
low, medium, high, or CHAOS. Each  
time the button is pressed, the fan  
speed mode is shifted.  
3
ON  
Natural wind by the CHAOS logic  
o For more fresh feeling than other fan speed, press the Indoor Fan  
Speed Selector and set to CHAOS mode. In this mode, the wind  
blows like natural breeze by automatically changing fan speed  
according to the CHAOS logic.  
During Healthy Dehumidification Operation:  
o If you select the dehumidification mode on the operation selection button, the A/C starts to run the  
dehumidification function. It automatically sets the room temp. and airflow volume to the best condition  
for dehumidification, based on the sensed current room temp.  
In this case, however, the setting temp. is not displayed in the remote control and you are not able to  
control the room temp. either.  
During the healthy dehumidification function, the airflow volume is automatically set according to the  
optimization algorithm responding to the current room temp. status which makes the room condition  
healthy and comfortable even in the high humidity season.  
o
12 Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Heating Operation(Heat pump model only)  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
Open the door on the remote control. To select Heating  
Operation, press the Operation Mode Selection button.  
Each time the button is pressed, the operation mode is  
shifted in the direction of the arrow.  
2
Cooling  
Auto  
Healthy  
Heating  
Dehumidification  
(Heat pump model only)  
Close the door on the remote control.  
Set the temperature higher than the room temperature.  
The temperature can be set within a range of 16°C~30°C in  
1°C increments.  
3
4
ON  
To raise the temperature  
To lower the temperature  
Set the fan speed again with the door of the  
remote control still closed. You can select  
the fan speed in four steps–low, medium,  
high and CHAOS. Each time the button is  
pressed, the fan speed mode is shifted.  
Natural wind by the CHAOS logic  
o For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to  
CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan  
speed according to the CHAOS logic.  
Owner’s Manual 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Jet Cool Operation  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
2
3
Press the Jet Cool button to operate  
the speed cooling mode and the unit  
will operate in super high fan speed  
on cooling mode for 30 minutes.  
For this operation P0 appears on the  
display. (Plasma model only)  
To cancel the Jet Cool mode, press the Jet Cool button or  
the fan speed button or the room temperature setting button  
again and the unit will operate in high fan speed on cooling  
mode.  
or  
or  
NOTICE  
o
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely  
high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used  
to cool the room temp. in the shortest time in a hot summer.  
In heat pump mode or neuro fuzzy mode, however, the JET COOL function is not available.  
o
In order to return to the normal cooling mode from the JET COOL mode, you just press  
either the operation mode selection button, airflow volume selection or temp. setting button  
or the JET COOL button again.  
14 Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
PLASMA Purification Operation(Optional)  
Press the Start/Stop button.  
The unit will respond with a  
beep.  
1
Open the door on the remote control.  
2
3
Press the PLASMA air purifying  
operation ON/OFF button.  
Operation will start when the button is  
pressed and stop when the button is  
pressed again.  
Make sure the plasma led lights up.  
Set the fan speed again with door of the remote control  
closed. You can select the fan speed in four  
steps-low, medium, high or CHAOS.  
Each time the button is pressed, the fan  
speed mode is shifted.  
Z Air purifying operation (PLASMA) can be with  
cooling, Heating or any other operations.  
PLASMA Air Purifying Operation only  
If you press the only PLASMA button, only  
PLASMA air purifying operates.  
Then, fan speed is low. You can select the fan  
speed in four steps-low, medium, high or  
CHAOS.  
Each time the button (  
speed mode is shifted.  
) is pressed, the fan  
Owner’s Manual 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
2nd F Operation  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
Open the door of the remote control and press the 2nd  
Function button to operate functions printed in blue at bottom  
of buttons.  
(Check the indication of 2nd function on remote control  
display.)  
2
These buttons operate the timer setting as follows:  
CANCEL  
SET  
ON  
OFF  
CANCEL  
ON  
OFF  
SET  
AUTO CLEAN  
2nd function goes off in a short time automatically or when  
the button is pressed again.  
3
For more details, refer to functions next page.  
16 Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Additional features  
Sleep Mode  
To cancel the Sleep Mode, press the sleep  
Mode Auto button several times until the star  
Press the Sleep Mode Auto button to set the  
time you want the unit to turn off automatically.  
1
2
(
) disappears from the operation display.  
The Timer is programmed in one-hour  
increments by pressing the Sleep Mode Auto  
button 1 to 7 times.  
The sleep mode is available for 1 to 7 times. To  
alter the time period in steps of 1 hour, press  
the Sleep Mode Button while aiming at air  
conditioner.  
sleeping.  
Make sure the Sleep Mode Auto LED lights up.  
3
1
Setting the Time  
Time can be set only when you have pressed  
the Reset button. If you have just replaced the  
batteries, the Reset button should be pressed  
to reset the time.  
Press the Time Setting buttons until the  
desired time is set.  
3
4
Press the Start/Stop button.  
CANCEL  
Press the Timer SET button.  
2
SET  
Press 2nd F button  
and check if 2nd F icon is on.  
NOTICE  
Check the indicator for A.M. and  
P.M.  
Owner’s Manual 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Vertical Airflow Direction Control  
The up/down airflow (Vertical Airflow) can be  
adjusted by using the remote control.  
NOTICE  
If you press the CHAOS swing button, at first 5 cycles,  
the horizontal louver will swing up and down at maximum  
angle. Then, the vertical airflow direction is changed  
automatically based on the CHAOS algorithm to distribute  
the air in the room evenly and at the same time to make  
the human body feel most comportable, as if enjoying  
a natural breeze.  
Always use the remote control to adjust the  
up/down airflow direction. Manually moving the  
vertical airflow direction louver by hand, could  
damage the air conditioner.  
Press the Start/Stop button to start the unit.  
1
2
o
Press Chaos Swing button and the louvers will  
swing up and down. Press the Chaos Swing  
button again to set the horizontal louver at the  
desired airflow direction.  
o
When the unit is shut off, the up/down airflow  
direction louver will close the air outlet vent of the  
system.  
To adjust left/right(Horizontal Airflow)  
direction  
Caution : Ensure that the  
unit is turned off before adjusting  
the horizontal airflow direction  
control. Carefully open vertical  
louver to allow access to the  
horizontal airflow direction.  
Adjust the left/right airflow  
direction by hand.  
Auto-Clean  
Whenever you press the Auto Clean button, Auto Clean Function will be reserved and  
cancelled.  
1
2
3
4
AUTO CLEAN  
Auto Clean function works before and after cooling or dehumidification mode. For details,  
refer to the below points.  
When the unit is started after the reservation of Auto Clean ,the Cool Start function  
operates and indoor Fan is started after 20 seconds.  
When you press Start/Stop button to turn off the unit after the you have reserved Auto  
Clean function, the air-conditioner circulates the indoor air in the Auto Clean mode with  
no more Cooling or Dehumidification operation.  
For Cooling only model, it lasts for 30 minutes for Heat pump model, for 16 minutes.  
If you press the auto clean button again during the product operation, Auto Clean  
function will be cancelled.  
5
For this operation  
C0  
appears on the display. (Plasma model only)  
NOTICE  
o
This function is to remove unpleasant smells from mold and other bacteria in the air-conditioner, and  
to remove humidity automatically during humidly summer, which supplies the indoor with purified air.  
Horizontal Airflow Direction Control (Optional)  
The left/right(Horizontal Airflow) can be adjusted by using the remote control.  
Press the Start/Stop button to start the unit.  
Open the door on the remote control. Press the Airflow Direction Start/Stop button  
and the louvers will swing left and right. Press the Horizontal Airflow Direction  
Control Button again to set the vertical louver at the desired airflow direction.  
18 Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
Air Circulation Mode  
Circulates the room air without cooling or heating.  
Press the Start/Stop button. the unit will respond with a beep.  
1
2
Open the door on the remote control. Press the Air Circulation button. Close the door on the  
remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is  
shifted from low to CHAOS and back to low again.  
CHAOS Air  
Fan speed is on low. Fan speed is on medium. Fan speed is on high.  
NOTICE  
o CHAOS Air economizes power consumption and prevents overcooling. The fan speed is  
automatically changed from high to low or vice versa, depending on the ambient temperature.  
Forced Operation  
Operation procedures when the remote control can't be used.  
The operation will be started if the power button is pressed.  
If you want to stop operation, re-press the button.  
Power  
button  
Open the front  
panel upward  
Heat pump Model  
Cooling Model  
Room Temp. 24°C  
Cooling  
21°C Room Temp. < 24°C  
Room Temp. < 21°C  
Heating  
Operating mode  
Indoor FAN Speed  
Setting Temperature  
Cooling  
High  
Healthy Dehumidification  
High  
High  
23°C  
High  
24°C  
22°C  
22°C  
Test operation  
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room  
temperature and resets in 18 minutes.  
During test operation, if remote controller signal is received, the unit operates as remote controller sets.  
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for about  
3 seconds.  
If you want to stop the operation, re-press the button.  
For this operation  
L
0
appears on the display. (Plasma model only)  
Auto restart(Optional)  
In case the power comes on again after a power failure, Auto Restarting Operation is the function to  
operate procedures automatically to the previous operating conditions.  
So there is no need of activating this function by pressing any key or button.  
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.  
As the compressor starts, the fan speed also resumes its previous setting mode.  
Additionally, in order to cancel auto restart operation press power button let it be pressed for about  
6 seconds. To operate auto restart operation again, press power button for about 6 seconds as well.  
Helpful information  
Fan speed and cooling capacity.  
The cooling capacity indicated in the specification is the value when the fan  
speed is set to high, and the capacity will be lower at low or medium fan speed.  
High fan speed is recommended when you wish to cool the room quickly.  
Owner’s Manual 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance and Service  
Maintenance and Service  
CAUTION: Before performing any maintenance, turn off the main power to the system.  
Indoor Unit  
o
Never use any of the followings:  
Grille, Case, and Remote Control  
Water hotter than 40°C  
Could cause deformation and/or  
discoloration.  
o Turn the system off before cleaning. To  
clean, wipe with a soft, dry cloth. Do not  
use bleach or abrasives.  
Volatile substances  
Could damage the surfaces of the air  
conditioner.  
NOTICE  
Supply power must be disconnected  
before cleaning the indoor unit.  
P
o
w
d
e
r
G
a
e
i
n
s
o
l
Air inlet vent  
Air outlet vent Air filters  
(behind front panel)  
Lift the front access panel and pull the filter tab  
slightly forward to remove the filter.  
Vertical louver Horizontal louver  
1
AIR FILTERS  
Clean the filter with a vacuum cleaner or  
warm, soapy water.  
• If dirt is conspicuous, wash with a  
solution of detergent in lukewarm water.  
• If hot water (40°C or more) is used, it  
may be deformed.  
The air filters behind the front grille should be  
checked and cleaned once in every 2 weeks or  
more often if neccessary.  
2
After washing with water, dry well in the  
shade.  
3
4
Re-install the air filter.  
NANO PLASMA FILTER, TRIPLE  
DEODORIZING FILTER(OPTIONAL)  
The PLASMA filter behind the air filters should be  
checked and cleaned once in every 3 months or  
more often if necessary.  
After removing the air filters, pull slightly  
forward to remove the NANO PLASMA filter.  
1
2
Remove dust with vacuum cleaner or air.  
(You should not try to wash with water).  
3
4
Note the cuts of electric discharge lines.  
Re-install the NANO PLASMA filter to the  
original position.  
TRIPLE DEODORIZING Filter  
NANO PLASMA Filter  
After removing the air filters, pull slightly  
forward to remove the TRIPLE  
DEODORIZING filter.  
1
2
3
Dry in the sunlight for two hours.  
Don’t touch this PLASMA Filter within 10  
seconds after opening the inlet grille, it may  
cause an electric shock.  
Re-install the TRIPLE DEODORIZING filter to  
the original position.  
20 Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance and Service  
Replacement of Purifying Filter(Optional)  
• Recomended use period : About 2 years  
Open front panel and remove air  
filters.  
Remove Triple deodorizing Filters.  
2
3
1
Insert new Triple deodorizing Filters.  
Air filter  
2
3
Reinsert air filters and close front  
panel.  
4
Triple Deodorizing Filter  
Outdoor Unit  
The heat exchanger coils and panel vents of the outdoor  
unit should be checked regularly. If clogged with dirt or  
soot, the heat exchanger and panel  
(Rear)  
(Side)  
vents may be professionally steam cleaned.  
Air intake  
vents  
Piping  
Drain Hose  
NOTICE  
Air outlet  
vents  
Dirty or clogged coils will reduce the  
operating efficiency of the system and cause higher  
operating costs.  
Owner’s Manual 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance and Service  
When the air conditioner is not going to be used for a long time.  
When air conditioner is not going to be  
When the air conditioner is to be used again.  
used for a long time.  
Clean the air filter and install it in the indoor  
unit.  
Operate the air conditioner on mode for 2 to  
3 hours.  
(Refer to page 20 for cleaning filters.)  
• This will dry out the internal mechanisms.  
Turn off the circuit breaker, and disconnect  
the plug.  
Check that the air inlet and outlet of the  
indoor/outdoor unit are not blocked.  
CAUTION  
CAUTION  
Turn off the circuit breaker when the air conditioner  
is not going to be used for a long time.  
Dirt may collect and may cause a fire.  
Remove the batteries from the remote  
control.  
Operation Tips  
Do not overcool the room.  
Keep blinds or curtains  
closed.  
Keep the room temperature  
uniform.  
This is not good for the health  
and wastes electricity.  
Do not let direct sunshine enter  
the room when the air  
conditioner is in operation.  
Adjust the vertical and  
horizontal airflow direction to  
ensure a uniform temperature  
in the room.  
Make sure that the doors  
and windows are shut tight.  
Clean the air filter regularly.  
Ventilate the room  
occasionally.  
Blockages in the air filter  
reduces the airflow and lowers  
the cooling and dehumidifying  
effects. Clean at least once in  
every two weeks.  
Since windows are kept closed,  
it is a good idea to open them  
and ventilate the room now and  
then.  
Avoid opening doors and  
windows as much as possible  
to keep the cool air in the room.  
22 Room Air Conditioner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance and Service  
Troubleshooting  
Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or  
service center.  
Case  
Explanation  
See page  
17  
The air conditioner does not  
operate.  
• Have you made a mistake in timer operation?  
• Has the fuse blown or has the circuit breaker  
been tripped?  
-
-
The room has a peculiar  
odor.  
• Check that this is not a damp smell exuded by  
the walls, carpet, furniture, or cloth items in the  
room.  
It seems that condensation  
is leaking from the air  
conditioner.  
• Condensation occurs when the airflow from  
the air conditioner cools the warm room air.  
-
-
Air conditioner does not  
operate for about 3 minutes  
when restarted.  
• This is the protector of the mechanism.  
• Wait about three minutes and operation will  
begin.  
Does not cool or heat  
effectively.  
• Is the air filter dirty? See air filter cleaning  
instructions.  
20  
• Has the temperature been set incorrectly?  
• Are the indoor unit's air inlet or outlet vents  
obstructed?  
9, 13  
-
The air conditioner  
operation is noisy.  
• For a noise that sounds like water flowing.  
-This is the sound of freon flowing inside the  
air conditioner unit.  
• For a noise that sounds like the compressed  
air releasing into atmosphere.  
-
-This is the sound of the dehumidifying water  
being processed inside the air conditioning  
unit.  
Remote control display is  
faint, or no display at all.  
• Are the batteries depleted?  
• Are the batteries inserted in the opposite (+)  
and (-) directions?  
7
-
Crack sound is heard.  
• This sound is generated by the  
expansion/constriction of the front panel, etc.  
due to changes of temperature.  
Owner’s Manual 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3M Carbon Monoxide Alarm GD 6 User Manual
3M Pet Fence 39600 User Manual
Abocom Network Router GP1000DM User Manual
Aiwa Stereo Receiver CDC MP3 User Manual
Alpine Car Video System TMX R705 User Manual
Altec Lansing Headphones MHP216 User Manual
Altec Lansing Portable Stereo System IMT520 User Manual
American DJ DJ Equipment BU 200 User Manual
Audiovox Speaker XS10 User Manual
Axis Communications Security Camera P1204 User Manual