Behringer Musical Instrument Amplifier FX VT100 User Manual

User Manual  
VIRTUBE  
VT250  
2 x 50-Watt Guitar Amplifier with 2 Independent Channels,  
VTC Tube Modeling, Dual FX and 2 Original BUGERA 12" Speakers  
VT100 /VT50  
100/60-Watt Guitar Amplifier with 2 Independent Channels,  
VTC Tube Modeling, Dual FX and Original BUGERA 12" Speaker  
VT100 H  
100-Watt Guitar Amplifier Head with 2 Independent Channels,  
VTC Tube Modeling and Dual FX  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
9. Do not defeat the safety purpose of the polarized  
TO BIND MUSIC GROUP BY ANY EXPRESS OR IMPLIED  
UNDERTAKING OR REPRESENTATION. THIS MANUAL  
IS COPYRIGHTED. NO PART OF THIS MANUAL MAY  
BE REPRODUCED OR TRANSMITTED IN ANY FORM  
Important Safety  
Instructions  
or grounding-type plug. A polarized plug has two blades  
with one wider than the other. A grounding-type plug  
has two blades and a third grounding prong. The wide  
blade or the third prong are provided for your safety. If the OR BY ANY MEANS, ELECTRONIC OR MECHANICAL,  
provided plug does not fit into your outlet, consult an  
electrician for replacement of the obsolete outlet.  
INCLUDING PHOTOCOPYING AND RECORDING OF ANY  
KIND, FOR ANY PURPOSE, WITHOUT THE EXPRESS  
WRITTEN PERMISSION OF MUSIC GROUP IP LTD.  
10. Protect the power cord from being walked on or  
pinched particularly at plugs, convenience receptacles,  
and the point where they exit from the apparatus.  
Terminals marked with this symbol carry  
electrical current of sufficient magnitude  
to constitute risk of electric shock.  
ALL RIGHTS RESERVED.  
© 2013 MUSIC Group IP Ltd.  
Trident Chambers, Wickhams Cay, P.O. Box 146,  
Road Town, Tortola, British Virgin Islands  
11. Use only attachments/accessories specified by  
the manufacturer.  
Use only high-quality professional speaker cables with  
¼" TS or twist-locking plugs pre-installed. All other  
installation or modification should be performed only  
by qualified personnel.  
12. Use only with the  
cart, stand, tripod, bracket,  
or table specified by the  
LIMITED WARRANTY  
For the applicable warranty terms and conditions  
and additional information regarding MUSIC Group’s  
Limited Warranty, please see complete details online at  
manufacturer, or sold with  
the apparatus. When a cart  
is used, use caution when  
moving the cart/apparatus  
combination to avoid  
This symbol, wherever it appears,  
alerts you to the presence of uninsulated  
dangerous voltage inside the  
enclosure - voltage that may be sufficient to constitute a  
risk of shock.  
injury from tip-over.  
This symbol, wherever it appears,  
alerts you to important operating and  
maintenance instructions in the  
13. Unplug this apparatus during lightning storms or  
when unused for long periods of time.  
14. Refer all servicing to qualified service personnel.  
Servicing is required when the apparatus has been  
damaged in any way, such as power supply cord or plug  
is damaged, liquid has been spilled or objects have fallen  
into the apparatus, the apparatus has been exposed  
to rain or moisture, does not operate normally, or has  
been dropped.  
accompanying literature. Please read the manual.  
Caution  
To reduce the risk of electric shock, do not  
remove the top cover (or the rear section).  
No user serviceable parts inside. Refer servicing to  
qualified personnel.  
Caution  
To reduce the risk of fire or electric shock,  
do not expose this appliance to rain and  
15. The apparatus shall be connected to a MAINS socket  
outlet with a protective earthing connection.  
16. Where the MAINS plug or an appliance coupler is  
used as the disconnect device, the disconnect device shall  
remain readily operable.  
moisture. The apparatus shall not be exposed to dripping  
or splashing liquids and no objects filled with liquids,  
such as vases, shall be placed on the apparatus.  
Caution  
These service instructions are for use  
by qualified service personnel only.  
To reduce the risk of electric shock do not perform any  
servicing other than that contained in the operation  
instructions. Repairs have to be performed by qualified  
service personnel.  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
LEGAL DISCLAIMER  
TECHNICAL SPECIFICATIONS AND APPEARANCES  
ARE SUBJECT TO CHANGE WITHOUT NOTICE AND  
ACCURACY IS NOT GUARANTEED. BEHRINGER,  
KLARK TEKNIK, MIDAS, BUGERA, AND TURBOSOUND  
ARE PART OF THE MUSIC GROUP (MUSIC-GROUP.COM).  
ALL TRADEMARKS ARE THE PROPERTY OF THEIR  
RESPECTIVE OWNERS. MUSIC GROUP ACCEPTS NO  
LIABILITY FOR ANY LOSS WHICH MAY BE SUFFERED  
BY ANY PERSON WHO RELIES EITHER WHOLLY OR  
IN PART UPON ANY DESCRIPTION, PHOTOGRAPH  
OR STATEMENT CONTAINED HEREIN. COLORS AND  
SPECIFICATIONS MAY VARY FROM ACTUAL PRODUCT.  
MUSIC GROUP PRODUCTS ARE SOLD THROUGH  
AUTHORIZED FULLFILLERS AND RESELLERS ONLY.  
FULLFILLERS AND RESELLERS ARE NOT AGENTS OF  
MUSIC GROUP AND HAVE ABSOLUTELY NO AUTHORITY  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in  
accordance with the manufacturer’s instructions.  
8. Do not install near any heat sources such as  
radiators, heat registers, stoves, or other apparatus  
(including amplifiers) that produce heat.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
1. Introduction  
Ensure adequate air supply and to avoid overheating do not place the unit  
near radiators etc.  
The demands placed on a guitar amp are nowadays very broad. A guitarist should  
offer a wide array of sounds. That’s why it is very important to us to be able to  
offer you maximum sound diversity as well as a variety of connection possibilities  
with your VIRTUBE. Don’t worry: you will quickly master the VIRTUBE and learn  
how to use all of its capabilities easily and intuitively. With its up-to-date  
circuitry, the VIRTUBE features the functionality and reliability of a truly modern  
guitar amp.  
Please make sure that all devices are properly grounded/earthed.  
For your own safety, never remove or disable the ground/earth  
conductors from the devices or on the power cords. The unit  
must always be connected to the mains outlet with a protective  
grounding connection.  
1.1.1 Online registration  
VTC Virtual Tube Circuitry  
Please register your new BEHRINGER equipment right after your purchase  
warranty carefully.  
The specially developed VTC Virtual Tube Circuitry gives your sound the unique  
vintage flavor of classic tube amps.  
Should your BEHRINGER product malfunction, it is our intention to have it  
repaired as quickly as possible. To arrange for warranty service, please contact  
the BEHRINGER retailer from whom the equipment was purchased. Should your  
BEHRINGER dealer not be located in your vicinity, you may directly contact  
one of our subsidiaries. Corresponding contact information is included in the  
original equipment packaging (Global Contact Information/European Contact  
Information). Should your country not be listed, please contact the distributor  
nearest you. A list of distributors can be found in the support area of our website  
(http://behringer.com).  
1.1 Before you get started  
Your product was carefully packed at the factory to ensure safe transport.  
Nevertheless, if the box is damaged inspect the unit immediately for signs  
of damage.  
If the unit is damaged please do NOT return it to us, but notify your  
dealer and the shipping company immediately; otherwise, claims for  
damage or replacement may not be granted.  
Otherwise, always use the original box to prevent damage during  
storage or transport.  
Registering your purchase and equipment with us helps us process your repair  
claims more quickly and efficiently.  
Make sure that children cannot play unsupervised with the unit or  
its packaging.  
Thank you for your cooperation!.  
Please ensure proper disposal of all packing materials.  
Recylce whenever possible.  
2. Control Elements  
(2)  
(9)  
(17)  
(1) (3) (4) (5) (6) (7) (8) (10) (11) (12) (13) (14) (15) (16) (18) (19) (20) (21) (22) (23)(24) (25) (26)  
Fig. 2.1: VIRTUBE control elements (front panel)  
2.1 Front panel  
(7) The TREBLE control adjusts the treble frequencies on the CLEAN channel.  
(1) The INPUT socket is the 1" connector for your guitar. Please use a standard  
1" TS connector.  
(8) Press the CHANNEL button to switch between the CLEAN and OVERDRIVE  
channels. The channel LED lights up when the channel is activated. With all  
models you can also switch between channels using the footswitch provided.  
2.1.1 CLEAN CHANNEL  
2.1.2 OVERDRIVE CHANNEL  
(2) The CLEAN CHANNEL LED lights up when the CLEAN channel is active.  
(3) The GAIN control determines the volume of the CLEAN channel.  
(9) The OVERDRIVE CHANNEL LED lights up when the channel is active.  
(10) The GAIN control determines the amount of gain applied and hence the  
(4) The CRUNCH button (VT100FXH and VT100FX only) allows you to add some  
degree of distortion in the OVERDRIVE channel.  
slight distortion to your clean sound, giving it a bit of “dirt” or “crunch”.  
(11) The OD1/OD2 button (VT100FXH and VT100FX only) switches between  
(5) The BASS control in the EQ section allows you to raise or lower the bass  
two different overdrive sounds.  
frequencies on the CLEAN channel.  
(12) The BASS control in the EQ section allows you to raise or lower the bass  
(6) With the MIDDLE control you can raise or lower the midrange frequencies  
frequencies on the OVERDRIVE channel.  
on the CLEAN channel.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
(13) With the MIDDLE control (VT100FXH and VT100FX only) you can raise or  
2.1.4 MASTER section  
lower the midrange frequencies on the OVERDRIVE channel.  
(22) The MASTER VOLUME control adjusts both the overall volume and  
(14) The TREBLE control adjusts the treble frequencies on the OVERDRIVE channel.  
the line out/headphones volume.  
(15) Use the CONTOUR control for additional, highly characteristic adjustment  
of the midrange, allowing you to easily create traditional as well  
as ultra-modern guitar sounds.  
(23) The VTC push button activates and deactivates the VTC Virtual Tube Circuitry.  
(24) The CD IN connector allows you to connect the output signal of a CD player,  
tape deck, or CD/MD walkman. For example, you can play back music CDs or  
CDs accompanying a guitar tutor while practising. This connector can also  
be used as a LINE OUT output. In this case, the guitar signal is output with no  
speaker simulation applied and can be routed to an external amp or mixing  
console. This will not mute the VIRTUBE’s built-in loudspeaker.  
(16) The VOLUME control adjusts the volume level of the OVERDRIVE channel.  
2.1.3 DIGITAL FX  
(17) The DIGITAL FX LED lights up when the effects processor is active.  
(18) Use the FX PRESET control to select one of 16 effects.  
(25) The LINE OUT/PHONES jack is for headphones connection. Internal speaker  
simulation is applied to the headphones signal in order to produce an  
authentic signal. The VIRTUBE’s built-in loudspeaker is muted when this  
connector is used.  
Preset  
1 - 4  
FX  
Chorus/Delay  
Delay  
The headphones output signal can also be routed to a mixing console or  
other sound reinforcement system. To do so, connect the headphones  
output with the line input on the mixing console. Use a standard cable  
with 1/4" TS connectors. If hum problems occur, you could insert a  
DI box, e.g. BEHRINGER ULTRA-DI DI100 or DI120.  
5 - 8  
9 - 12  
13 - 16  
Chorus  
Flanger  
Tab. 2.1: Effects  
(19) The FX LEVEL control adjusts the mix ratio between the original and  
Some headphones tend to produce distortion with too high  
volume level. Please turn down the volume a bit, until distortion stops.  
the effect signal.  
(20) The REVERB LEVEL control determines the effect intensity of the  
(26) The POWER switch turns your VIRTUBE on and off. It should always be in the  
additional reverb effect.  
OFF position when connecting the unit to the mains.  
(21) The FX LOOP MIX control (VT100FXH and VT100FX only) determines  
Please note: Merely switching the unit off does not mean that it is fully  
disconnected from the mains. To disconnect the unit from the mains,  
pull out the mains connector. Before installation, please make sure  
that the mains connector has not been damaged. If you do not use the  
unit for an extended period of time, please disconnect it at the mains.  
the effect intensity of the external effect (see Chapter 2.2.1 FX LOOP).  
(28)  
(30)  
(35)  
(27)  
(29)  
(33) (31) (32) (34)  
Fig. 2.2: VIRTUBE control elements (rear panel)  
2.2 Rear panel  
(L/R). Always use speakers with a minimum impedance of 8 Ω to ensure  
maximum power output. Using the SPEAKER OUT connectors will mute the  
built-in loudspeakers.  
(27) The VIRTUBE is connected to the mains using a standard IEC receptacle.  
A suitable power cord is included with the unit.  
(28) FUSE HOLDER/VOLTAGE SELECTOR. Before connecting the unit to  
the mains, ensure that the voltage setting matches your local voltage.  
Blown fuses must be replaced with a fuse of the same type and rating.  
On some units, the fuse holder can be switched to one of two positions,  
2.2.1 FX LOOP  
(31) The FX LEVEL button allows you to adapt the FX LOOP to the operating level  
of an external effects device (+4 dBu/-10 dBV).  
i.e. 230 V and 120 V. Please note: when operating the unit outside Europe at  
120 V, a higher fuse rating is required (see Chapter 4, “Installation”).  
(32) The VIRTUBE provides a serial insert path for inserting external effects  
(e.g. reverb processor). To do so, connect the FX SEND jack to the input of the  
effects device.  
(29) This is where the fan of the unit is located.  
The FX SEND can also be used as a parallel output with no effects,  
for example, to record a “dry” guitar signal. As long as the RETURN jack  
is not in use, there will be no break in the internal signal path.  
(30) The SPEAKER OUT connectors (only one on the VT100FX and VT50FX)  
can be used to connect external speakers with a miminum impedance of  
4 Ω. The outputs of the VT250FX deliver 50 Watts of power per channel  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
(33) Connect the FX RETURN jack to the output of the external effects device.  
3.2 Recording set-up with effects device  
The VT250FX has two jacks (L/R) because it is a stereo amplifier.  
(34) Use the FOOTSWITCH jack to connect the 1" TRS plug of the footswitch  
supplied with the unit. The footswitch performs a dual function: it switches  
between the two channels and turns the DIGITAL FX on and off.  
(35) SERIAL NUMBER.  
3. Application Examples  
The VIRTUBE features plenty of connectors for a wealth of applications.  
Here’s a few examples of how flexible your VIRTUBE can be:  
3.1 Set-up for practicing with playbacks  
Footswitch  
Drum Computer  
HPS3000  
CD Player  
CD In  
Fig. 3.2: Recording set-up with the VT100FX  
VIRTUBE VT50FX  
If you want to use your VIRTUBE in a home-recording or studio environment,  
please wire it as shown in Fig. 3.2. Of course, you can still use a CD player  
or drum computer in this set-up. This is not shown here to provide for a  
better overview. Connect the input of the effects device to the FX SEND and  
the effects output to the FX RETURN.  
If you want to record your guitar signal with effects, connect the PHONES output  
to your mixing console, audio sequencer or multi-track recorder.  
To record a “dry” guitar signal with no effect, it is best to use the FX SEND  
connector. You can use both outputs at the same time, for example, to record  
signals via the FX SEND output (no effect), while monitoring them via the PHONES  
output (with effect).  
Electric Guitar  
Fig. 3.1: VT50FX standard set-up  
Instead of an external 19" effects processor, you can also use a wah-wah pedal  
or other stomp box. However, please note that the FX LOOP is post-preamp,  
i.e. after the distortion stages.  
For practising in the rehearsal room or at home, please wire your VIRTUBE as  
shown in Fig. 3.1. Connect a CD player or drum computer to the CD IN input.  
If you want to practice with headphones, connect your headphones to the  
PHONES jack. The built-in loudspeaker will be muted automatically. Connect the  
dual footswitch supplied with the unit to the FOOTSWITCH jack on the VIRTUBE.  
The CHANNEL footswitch switches between the channels. The EFFECT button  
switches the effect on and off.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
3.3 Live set-up with external speaker box  
3.4 Wiring the VT100FXH  
The VT100FXH has two SPEAKER OUT outputs for connection of one or two  
external speaker cabinets. To achieve maximum power output on the VT100FXH,  
both speaker outputs should be connected to speaker cabinets with a minimum  
impedance of 4 Ω. Connecting headphones to the PHONES jack will automatically  
mute the speaker outputs.  
Fig. 3.4: VT100FXH with two speaker boxes  
Fig. 3.3: Set-up comprising VT250FX and one speaker box  
Fig. 3.3 shows how the LINE OUT signal is routed to a mixing console. You can  
connect external guitar speaker boxes to the SPEAKER OUT outputs of the  
VIRTUBE (VT100FX and VT50FX have only one output) to achieve more power  
and higher volume levels on stage. When the VT250FX is used, we recommend  
connecting two separate speaker cabinets for stereo applications or one stereo  
cabinet (e.g. BEHRINGER ULTRASTACK BG412S).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
4. Installation  
Except for the headphones output and the CD IN input (1" TRS connectors),  
all audio inputs and outputs on the BEHRINGER VIRTUBE are on 1" TS connectors.  
Please see Chapter 5, “Specifications” for more information.  
Please ensure that the unit is installed and operated only by people  
qualified to do so. During installation and operation the user must have  
sufficient electrical contact to earth. Electrostatic discharge may affect  
the operation of the unit.  
Fig. 4.3: Stereo adapter cable  
Fig. 4.4: Mono adapter cable  
Fig. 4.1: 1" TS connector  
Fig. 4.2: 1" TRS connector  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
5. Specifications  
VT250FX  
Audio Inputs  
Power Supply  
Input  
1" TS, RF filtered  
Power consumption  
Fuse  
max. 180 Watts  
Input impedance  
FX Return  
approx. 1 MΩ, unbalanced  
2 x 1" TS  
100 V~, 50/60 Hz  
120 V~, 50/60 Hz  
220 - 230 V~, 50/60 Hz  
Mains connection  
T 3.15 A H 250 V  
Input impedance  
CD In  
approx. 33 kΩ, unbalanced  
1" TRS  
T 2.5 A H 250 V  
T 1.25 A H 250 V  
Standard IEC receptacle  
Input impedance  
approx. 5.6 kΩ, unbalanced  
Audio Outputs  
Dimensions / Weight  
FX Send  
1" TS  
Dimensions (H x W x D)  
520 x 670 x 275 mm  
(20.5 x 26.3 x 10.8")  
Output impedance  
Line Out / Phones  
Output level  
approx. 5.6, kΩ unbalanced  
1" TRS, unbalanced  
max. +16 dBV / 100 Ω  
Weight  
22.2 kg (48.8 lbs)  
Loudspeaker Outputs  
Type  
2 x 1"  
Min. load impedance  
2 x 8 Ω  
Amplifier  
Peak power  
2 x 50 Watts / 8 Ω  
Digital Signal Processing  
Converter  
24-bit, sigma-delta  
40 kHz  
Sample rate  
Loudspeaker  
Size  
2 x 12"  
Model  
BUGERA Vintage Guitar Series 2 x 12G50J8  
Impedance  
2 x 8 Ω  
Continuous power (IEC268-5)  
Peak power  
2 x 50 Watts  
2 x 200 Watts  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10 VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
VT100FX  
Audio Inputs  
Power Supply  
Input  
1" TS, RF filtered  
approx. 1 MΩ, unbalanced  
1" TS  
Power consumption  
Fuse  
max. 180 Watts  
Input impedance  
FX Return  
100 V~, 50/60 Hz  
120 V~, 50/60 Hz  
220 - 230 V~, 50/60 Hz  
Mains connection  
T 2.5 A H 250 V  
Input impedance  
CD In  
approx. 33 kΩ, unbalanced  
1" TRS  
T 2.5 A H 250 V  
T 1.0 A H 250 V  
Input impedance  
approx. 5.6 kΩ, unbalanced  
Standard IEC receptacle  
Audio Outputs  
Dimensions / Weight  
FX Send  
1" TS  
Dimensions (H x W x D)  
550 x 580 x 275 mm  
(21.6 x 22.8 x 10.9")  
Output impedance  
Line Out / Phones  
Output level  
approx. 8.2, kΩ unbalanced  
1" TRS, unbalanced  
max. +16 dBV / 100 Ω  
Weight  
20.4 kg (44.9 lbs)  
Loudspeaker Outputs  
Type  
1"  
Min. load impedance  
4 Ω  
Amplifier  
Peak power  
100 Watts / 4 Ω  
Digital Signal Processing  
Converter  
24-bit, sigma-delta  
40 kHz  
Sample rate  
Loudspeaker  
Size  
12"  
Model  
BUGERA Vintage Guitar Series 12G70J4  
Impedance  
4 Ω  
Continuous power (IEC268-5)  
Peak power  
70 Watts  
280 Watts  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11 VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
VT50FX  
Audio Inputs  
Power Supply  
Input  
1" TS, RF filtered  
approx. 1 MΩ, unbalanced  
1" TS  
Power consumption  
Fuse  
max. 90 Watts  
Input impedance  
FX Return  
100 V~, 50/60 Hz  
120 V~, 50/60 Hz  
220 - 230 V~, 50/60 Hz  
Mains connection  
T 1.6 A H 250 V  
Input impedance  
CD In  
approx. 33 kΩ, unbalanced  
1" TRS  
T 1.25 A H 250 V  
T 630 mA H 250 V  
Standard IEC receptacle  
Input impedance  
approx. 5.6 kΩ, unbalanced  
Audio Outputs  
Dimensions / Weight  
FX Send  
1" TS  
Dimensions (H x W x D)  
520 x 515 x 275 mm  
(20.5 x 20.3 x 10.8")  
Output impedance  
Line Out / Phones  
Output level  
approx. 5.6, kΩ unbalanced  
1" TRS, unbalanced  
max. +16 dBV / 100 Ω  
Weight  
16.5 kg (36.3 lbs)  
Loudspeaker Outputs  
Type  
1"  
Min. load impedance  
8 Ω  
Amplifier  
Peak power  
60 Watts / 8 Ω  
Digital Signal Processing  
Converter  
24-bit, sigma-delta  
40 kHz  
Sample rate  
Loudspeaker  
Size  
12"  
Model  
BUGERA Vintage Guitar Series 12G50J8  
Impedance  
8 Ω  
Continuous power (IEC268-5)  
Peak power  
50 Watts  
200 Watts  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual  
VT100FXH  
Audio Inputs  
Power Supply  
Input  
1" TS, RF filtered  
approx. 1 MΩ, unbalanced  
1" TS  
Power consumption  
Fuse  
max. 180 Watts  
Input impedance  
FX Return  
100 V~, 50/60 Hz  
120 V~, 50/60 Hz  
220 - 230 V~, 50/60 Hz  
Mains connection  
T 2.5 A H 250 V  
Input impedance  
CD In  
approx. 33 kΩ, unbalanced  
1" TRS  
T 2.5 A H 250 V  
T 1.0 A H 250 V  
Input impedance  
approx. 5.6 kΩ, unbalanced  
Standard IEC receptacle  
Audio Outputs  
Dimensions / Weight  
FX Send  
1" TS  
Dimensions (H x W x D)  
250 x 580 x 270 mm  
(9.8 x 22.8 x 10.6")  
Output impedance  
Line Out / Phones  
Output level  
approx. 8.2, kΩ unbalanced  
1" TRS, unbalanced  
max. +16 dBV / 100 Ω  
Weight  
12.7 kg (27.9 lbs)  
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts,  
modifications may be made from time to time to existing products without prior notice. Specifications and  
appearance may differ from those listed or illustrated.  
Loudspeaker Outputs  
Type  
2 x 1"  
Min. load impedance  
4 Ω  
Amplifier  
Peak power  
100 Watts / 4 Ω  
Digital Signal Processing  
Converter  
24-bit, sigma-delta  
40 kHz  
Sample rate  
Loudspeaker  
Size  
Model  
Impedance  
Continuous power (IEC268-5)  
Peak power  
Download from Www.Somanuals.com. All Manuals Search And Download.  
We Hear You  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Two Way Radio B 406 User Manual
Acer Laptop Z03 User Manual
Adaptec Computer Hardware SBC 596 User Manual
Agilent Technologies Network Card 34398A RS 232 User Manual
Agri Fab Lawn Mower 45 0461 User Manual
Alpine CD Player CDA 7990 User Manual
Aluratek Switch AVW04H User Manual
Amana Clothes Dryer LEA20AW User Manual
American Dryer Corp Clothes Dryer AD 630 User Manual
Behringer Music Mixer MX9000 User Manual