Barco Car Video System MDCC 6230 User Manual

Coronis Fusion 6MP  
User Guide  
MDCC-6230  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Coronis Fusion 6MP  
User Guide  
MDCC-6230  
K5902055/01  
28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Barco nv  
President Kennedypark 35, 8500 Kortrijk, Belgium  
Phone: +32 56.23.32.11  
Fax: +32 56.26.22.62  
Printed in Belgium  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of contents  
TABLE OF CONTENTS  
K5902055 CORONIS FUSION 6MP 28/08/2013  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Welcome!  
1. WELCOME!  
1.1 About the product  
Overview  
Thank you for choosing this Coronis Fusion 6MP!  
Coronis Fusion 6MP is an ingenious PACS display system designed to further enhance exibility and  
productivity in diagnostic imaging. Featuring the industry’s rst 30-inch color LCD that can be used as two  
seamless heads or one wide-screen display, Coronis Fusion 6MP offers you the freedom to organize your  
workspace just the way you want it. It allows you to read CT, MR, cath and echo cardiogram images, or  
any other combination, side by side on a single diagnostic screen. Coronis Fusion 6MP features the latest,  
breakthrough In-Plane Switching (IPSPro) LCD technology. This technology brings the most advanced  
LCD viewing characteristics on the market, setting new standards for brightness and contrast, even from  
a wide viewing angle. Use the instructions in this guide to install your Coronis Fusion 6MP display and  
discover all these interesting features yourself!  
CAUTION: Read all the important safety information before installing and operating your  
Coronis Fusion 6MP. Please refer to the dedicated chapter in this user guide.  
1.2 What’s in the box  
Overview  
Your Coronis Fusion 6MP comes with:  
this Coronis Fusion 6MP user guide  
a system CD  
two DVI cables  
two DisplayPort cables  
a USB cable  
a set of AC power cords  
an external power supply  
If you ordered a Barco display controller, it’s also in the box together with its accessories. A dedicated  
user guide is available on the system CD.  
Keep your original packaging. It is designed for this display and is the ideal protection  
during transport and storage.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
1. Welcome!  
4
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Parts, controls and connectors  
2. PARTS, CONTROLS AND  
CONNECTORS  
2.1 Display front view  
Overview  
8
1
2
3
4
5
6
7
Image 2-1  
Front view  
1
3
5
7
2
4
6
8
USB downstream connectors  
Right/Down key  
Left/Up key  
Menu/Enter key  
Stand-by/Cancel key  
Control wheel  
Power status indicator light  
Ambient light sensor  
K5902055 CORONIS FUSION 6MP 28/08/2013  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2. Parts, controls and connectors  
2.2 Display rear view  
Overview  
1
2
3
4
5
6
7
8
9
10  
11 12  
Image 2-2  
Rear view  
1
3
2
4
+24 VDC power input  
DVI 2 video input  
+5 VDC, 0.5 A power output  
DisplayPort 2 video input  
Neck cover  
5
6
Connector compartment cover  
DisplayPort 1 video input  
DVI 1 video input  
7
8
Display stand cover  
9
10  
12  
Ethernet connector (see note below)  
USB downstream connector  
11  
USB upstream connector  
The Ethernet connection is used for maintenance purposes and is not supported for  
user application.  
6
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Display installation  
3. DISPLAY INSTALLATION  
Prior to installing your Coronis Fusion 6MP and connecting all necessary cables, make  
sure to have a suitable display controller physically installed in your computer. If you  
are using a Barco display controller, please consult the user guide delivered with it to  
do this.  
3.1 Removing the covers  
The connector compartment cover should be removed to get access to the connectors.  
To remove the connector compartment cover  
1. Gently lift the clips at one of the handles of the connector compartment cover to release that side of the  
cover.  
2. Do the same at the other side of the cover.  
3. Remove the cover.  
The display stand cover should be removed to get access to the cable routing channel.  
To remove the display stand cover  
1. Gently press and hold the clips at the inside top of the cover.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3. Display installation  
2. Slide the cover upwards while holding the clips pressed.  
3.2 Unlocking the height mechanism  
In the factory, the height-positioning system in the display stand is locked with a red  
hook to prevent damage during transportation. You’ll have to remove this hook before  
adjusting your display height position.  
To remove the hook:  
1. Position the display with its rear side facing you.  
2. While holding the display panel pushed down, pull out the red hook in the display stand.  
8
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Display installation  
3. Keep the clip in the dedicated hole in case the display needs to be shipped later.  
To retain the hook for possible future transportation, insert the short, red end of the  
hook back into the stand of your display.  
3.3 Adjusting the display position  
Now that the height-positioning system of your display is unlocked, you can adjust the  
display position.  
To adjust the display position  
1. Tilt, swivel, raise and lower the display as desired.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Display installation  
CAUTION: Do not try to pivot your display when attached to the stand. Trying to do so  
could cause serious damage to your display and its stand.  
3.4 Connecting the signal cables  
To get access to the connectors, remove the connector compartment cover. See "Re-  
Each side of your display can have a different video input connected (one side can have  
DVI connected while the other side has DisplayPort connected). Both display sides can  
have the same video input connected as well but only one video input is allowed on each  
side of your display.  
To connect the signal cables to the display:  
1. Connect one head of the display controller to the DVI 1 or DisplayPort 1 connector with one of the  
supplied DVI or DisplayPort cables.  
2. Connect another head of the display controller to the DVI 2 or DisplayPort 2 connector with one of the  
supplied DVI or DisplayPort cables.  
3. If you want to make use of your display’s USB downstream connectors, connect a PC USB downstream  
connector to the display’s USB upstream connector by means of the supplied USB 2.0 cable.  
10  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Display installation  
3.5 Connecting the power cable  
To connect the power cable to the display:  
1. Connect the supplied external DC power supply to the +24 VDC power input of your Coronis Fusion  
6MP display.  
2. Plug the other end of the external DC power supply into a grounded power outlet by means of the proper  
power cord delivered in the packaging.  
3.6 Routing the cables  
To route the cables  
1. Route all connected cables through the cable routing channel in the stand of your display.  
Tip: The cable straps at the inside of the connector compartment allow you to x the cables for better  
shielding of the cables.  
3.7 Re-attaching the covers  
To re-attach the display stand cover  
1. Slide the display stand cover downward. You’ll hear a “click” sound of the cover’s clips when the display  
stand cover is in position.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
3. Display installation  
Pay attention that all cables stay in the cable channel while re-attaching the cover.  
To re-attach the connector compartment cover  
1. Slide the cover’s top in position and then push the cover’s bottom. You’ll hear a “click” sound of the  
cover’s clips when the connector compartment cover is in position.  
3.8 VESA-mount installation  
WARNING: Use an arm that is approved by VESA (according to the VESA 100 mm stan-  
dard).  
Use an arm that can support the weight of the display. Refer to the technical specica-  
tions of this display for the applicable weight.  
CAUTION: You should mount the panel in landscape position. Portrait position is pos-  
sible but not supported.  
Overview  
The panel, standard attached to a stand, is compatible with the VESA 100 mm standard. Thus, it can be  
used with an arm that is approved by VESA. This chapter shows you how to release the panel from the  
stand and how to attach it to an arm. If you’re not using an arm, you can skip this chapter.  
12  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Display installation  
1. Gently pull open both lower sides of the cover.  
2. Slide the cover upwards while holding the lower sides pulled open.  
3. Lift the plastic frame that covers the xation of the panel to the stand. Turn it for 45 degrees to uncover  
the xation screws.  
4. Unscrew the four xation screws xing the panel to the stand.  
5. Attach the panel rmly to the arm using 4 screws M4 x 10 mm.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Display installation  
WARNING: Never move a display attached to an arm by pulling or pushing the display  
itself. Instead, make sure that the arm is equipped with a VESA approved handle and  
use this to move the display.  
Please refer to the instruction manual of the arm for more information and instructions.  
3.9 First time starting up  
Overview  
You are now ready to start up your Coronis Fusion 6MP for the rst time.  
1. Switch on your Coronis Fusion 6MP as described in "Stand-by switching", page 16.  
2. Turn on the computer connected to your display.  
If you have properly installed your display and display controller, the Windows start-up messages will  
appear once the boot procedure is nished.  
Your Coronis Fusion 6MP display will be running in a basic video mode at a default re-  
fresh rate when rst time starting up. If you are using a Barco display controller, please  
consult the dedicated user guide available on the system CD to install the drivers, soft-  
ware and documentation. When this is done, your display will automatically detect the  
connected video input signal(s) and apply the correct video mode and refresh rate.  
14  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Daily operation  
4. DAILY OPERATION  
4.1 Recommendations for daily operation  
Optimize the lifetime of your display  
Enabling the Display Power Management System (DPMS) of your display will optimize its diagnostic life-  
time by automatically switching off the backlight when the display is not used for a specied period of time.  
By default, DPMS is enabled on your display, but it also needs to be activated on your workstation. To do  
this, go to “Power Options Properties” in the “Control Panel”.  
Barco recommends setting DPMS activation after 20 minutes of non-usage.  
Use a screen saver to avoid image retention  
Prolonged operation of an LCD with the same content on the same screen area may result in a form of  
image retention.  
You can avoid or signicantly reduce the occurrence of this phenomenon by using a screen saver. You  
can activate a screen saver in the “Display properties” window of your workstation.  
Barco recommends setting screen saver activation after 5 minutes of non-usage. A  
good screen saver displays moving content.  
In case you are working with the same image or an application with static image elements for several hours  
continuously (so that the screen saver is not activated), change the image content regularly to avoid image  
retention of the static elements.  
Understand pixel technology  
LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a  
limited number of these pixels may remain either dark or permanently lit, without affecting the diagnostic  
performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its  
LCD panels.  
To learn more about LCD technology and missing pixels, consult the dedicated white  
papers available at www.barco.com/healthcare.  
Enhance user comfort  
Every Barco multi-head display system is color matched with the highest specications in the market.  
Barco recommends keeping color-matched displays together. Furthermore, it is impor-  
tant to use all displays of a multi-head conguration at the same rate to preserve color  
matching throughout the economic lifetime of the system.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4. Daily operation  
Maximize quality assurance  
The ’MediCal QAWeb’ system offers online service for high-grade Quality Assurance, providing maximum  
diagnostic condence and uptime.  
Barco recommends to install MediCal QAWeb Agent and apply the default QAWeb policy  
at least. This policy includes calibration on regular intervals. Connecting to MediCal  
QAWeb Server offers even more possibilities.  
Learn more and sign up for the free MediCal QAWeb Essential level at  
4.2 Key indicator lights  
To make the keys light up:  
1. Gently sweep your nger over the bottom right hand side of your display.  
As a result, the keys will light up and are now available for further actions. However, if no further actions  
are taken within the following 5 seconds, the key indicator lights will dim again.  
The key auto-dim function can be disabled in the OSD menus. Please refer to "Key in-  
dicator lights", page 20 for detailed instructions on how to do this.  
4.3 Stand-by switching  
The connected power supply also provides a switch that can be used to turn the power  
completely off. To use the display, please make sure to switch on this power supply.  
This can be done by pushing the on/off switch on the power supply into the “” position.  
16  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4. Daily operation  
Switching on the display while it is in stand-by mode or vice versa can both be done by  
using the keys or by using the control wheel.  
To switch your display on using the keys:  
1. Light up the keys indicator lights as previously described.  
2. While the keys are light up, touch the Stand-by/Cancel key for approximately 2 seconds.  
As a result, the display will switch on and the power status indicator light is dimmed.  
To switch your display on using the control wheel:  
1. Press the control wheel for approximately 2 seconds.  
As a result, the display will switch on and the power status indicator light is dimmed.  
The power LED can be disabled in the OSD menus. Please refer to "Power status indi-  
cator light", page 20 for detailed instructions on how to do this.  
To switch your display to Stand-by using the keys:  
1. Light up the keys indicator lights as previously described.  
2. While the keys are light up, touch the Stand-by/Cancel key, a small window pops-up. Press the button  
again to conrm.  
As a result, the display will switch to stand-by mode and the power status indicator light is orange.  
To switch your display to Stand-by using the control wheel:  
1. Press the control wheel once, a small window pops-up. Press the control wheel again to conrm.  
As a result, the display will switch to stand-by mode and the power status indicator light is orange.  
In case of a power outage recovery, your display will always start-up in the power mode  
it was in before the power interruption (i.e. stand-by or on). This protects your display  
against inadvertent image retention problems.  
4.4 Bringing up the OSD menus  
About OSD menu  
The OSD menu allows you to congure different settings to make your Coronis Fusion 6MP display t your  
needs within your working environment. Also, you can retrieve general information about your display and  
its current conguration settings through the OSD menu.  
Bringing up the OSD menus can be done by using the keys or by using the control wheel.  
How to bring up the OSD menus using the keys  
1. If not already done so, switch on the display as previously described.  
2. Light up the keys indicator lights as previously described.  
3. While the keys light up, touch the Menu/Enter key.  
As a result, the OSD main menu comes up in the bottom right corner of the screen. If no further actions  
are taken within the following 90 seconds however, the OSD menu will disappear again.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Daily operation  
How to bring up the OSD menus using the control wheel  
1. If not already done so, switch on the display as previously described.  
2. Shortly turn the control wheel.  
As a result, the OSD main menu comes up in the bottom right corner of the screen. If no further actions  
are taken within the following 90 seconds however, the OSD menu will disappear again.  
The OSD menu auto-exit function can be disabled in the OSD menu. Please refer to  
"OSD menu automatic close function", page 19 for detailed instructions on how to do  
this.  
The OSD menu position can be modied in the OSD menu. Please refer to "OSD menu  
position", page 19 for detailed instructions on how to do this.  
4.5 Navigating through the OSD menus  
About OSD menu navigation  
Navigating through the OSD menu can be done by using the keys or by using the control wheel.  
How to navigate through the OSD menus using the keys  
1. Use the Right/Down and Left/Up keys to move through the (sub)menus, change values or make selec-  
tions.  
2. To go into a submenu or conrm adjustments and selections, use the Menu/Enter key.  
3. Use the Stand-by/Cancel key to cancel adjustments or exit a (sub)menu.  
4. Exit the OSD menu by touching the Stand-by/Cancel key for approximately 2 seconds.  
How to navigate through the OSD menus using the control wheel  
1. Rotate the control wheel to move through the menus, change values or make selections.  
2. To go into a submenu or conrm adjustments and selections, shortly click the control wheel.  
3. Click the control wheel for approximately 2 seconds to cancel adjustments or exit a (sub)menu.  
18  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5. Advanced operation  
5. ADVANCED OPERATION  
5.1 OSD menu position  
About the OSD menu position  
By default, the OSD menu comes up in the bottom center position of the screen. This position can be  
modied however. There’s choice from a number of predened positions.  
To change the position of the OSD menu:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > User Interface > Menu menu.  
3. Enter the Position submenu.  
4. Select one of the available OSD menu positions and conrm.  
5.2 OSD menu language  
About the OSD menu language  
By default, the OSD menu comes up in English. However, there’s a wide range of other languages avail-  
able for the OSD menu of your Coronis Fusion 6MP.  
To change the language of the OSD menu:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > User Interface > Menu menu.  
3. Enter the Language submenu.  
4. Select one of the available languages and conrm.  
5.3 OSD menu automatic close function  
About the OSD menu automatic close function  
By default, the OSD menu will disappear automatically after approximately 90 seconds of inactivity. How-  
ever, this function can be disabled so that the OSD menu remains on the screen until manually closed.  
To enable/disable the OSD menu automatic close function:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > User Interface > Menu menu.  
3. Enter the Automatic Close submenu.  
4. Select Enabled/Disabled as desired and conrm.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5. Advanced operation  
5.4 Power status indicator light  
About the power status indicator light  
By default, when the display is switched on, the power status indicator light is dimmed. This behavior can  
be changed so that the power status indicator light will be blue when the display is switched on.  
When the display is in stand-by mode, the power status indicator light will always turn  
orange, even when the power status indicator light is disabled.  
To enable/disable the power status indicator light:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > User Interface > Indicator Lights menu.  
3. Enter the Power Status submenu.  
4. Select Enabled/Disabled as desired and conrm.  
5.5 Key indicator lights  
About the key indicator lights  
By default, after lighting up, the key indicator lights will dim again if no further actions are taken within the  
following 5 seconds. However, this behavior can be changed so that the key indicator lights are always  
on or always off.  
To congure the key indicator lights  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > User Interface > Indicator Lights menu.  
3. Enter the Keys submenu.  
4. Select Automatic/Always On/Always Off as desired and conrm.  
5.6 Power lock function  
About the power lock function  
By enabling the power lock function, the Coronis Fusion 6MP is forced to remain switched on. This means  
that it can’t be switched to stand-by mode until the power lock function is disabled again.  
To enable/disable the power lock function:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > User Interface > Controls menu.  
3. Enter the Power Lock submenu.  
4. Select Enabled/Disabled as desired and conrm.  
20  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5. Advanced operation  
5.7 Keys sound  
About keys sound  
By default, the keys will make a “beep” sound on every touch. However, this sound can be disabled so  
that no sound will be heard when using the keys.  
To enable/disable the keys sound:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > User Interface > Controls menu.  
3. Enter the Sound submenu.  
4. Select Enabled/Disabled as desired and conrm.  
5.8 Ethernet over USB  
About Eth. over USB  
By default, the Ethernet over USB will be disabled. This does not disable the USB hub and still allows  
to make use of the display’s USB downstream connectors and any external devices connected to it (key-  
board, mouse, ...).  
Please note that a connection from a PC USB downstream connector to the display’s USB upstream  
connector is required to be able to use this functionality.  
By enabling the Ethernet over USB, you allow the internal Coronis Fusion 6MP processor to communicate  
directly over USB with the connected PC.  
Enabling the Ethernet over USB is only recommended when you are using a non-Barco  
display controller. If you are using a Barco display controller, this communication will  
automatically be done over the connected video cable(s).  
To enable/disable the eth. over USB:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Connectivity menu.  
3. Enter the Eth. over USB submenu.  
4. Select Enabled/Disabled as desired and conrm.  
5.9 USB  
About USB  
By default, USB will be enabled. This will allow the connected PC to communicate directly over USB with  
the internal Coronis Fusion 6MP processor.  
By disabling USB, communication between the internal Coronis Fusion 6MP processor and the connected  
PC will not be possible. This does not disable the USB hub and still allows to make use of the display’s  
USB downstream connectors and any external devices connected to it (keyboard, mouse, ...).  
Please note that a connection from a PC USB downstream connector to the display’s USB upstream  
connector is required to be able to use this functionality.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5. Advanced operation  
Enabling the USB endpoint is only recommended when you are using a non-Barco dis-  
play controller. If you are using a Barco display controller, this communication will au-  
tomatically be done over the connected video cable(s).  
To enable/disable USB:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Connectivity menu.  
3. Enter the USB submenu.  
4. Select Enabled/Disabled as desired and conrm.  
5.10 DPMS mode  
About DPMS mode  
Enabling the Display Power Management System (DPMS) mode on your display will optimize its diagnos-  
tic lifetime by automatically switching off the backlight when the display is not used for a specied period  
of time. By default, DPMS mode is enabled on your display, but it also needs to be activated on your  
workstation. To do this, go to the “Power options properties” window of your workstation.  
Barco recommends setting DPMS activation after 20 minutes of non-usage.  
When DPMS mode is enabled on your display, an additional OSD power saving function  
becomes available: hibernate. Please refer to "Hibernate", page 22 for more information  
on hibernation and how to enable this function.  
To enable/disable DPMS mode on your display:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Power Management menu.  
3. Enter the DPMS Mode submenu.  
4. Select Enabled/Disabled as desired and conrm.  
5.11 Hibernate  
About hibernate  
Enabling hibernation will not only switch off the backlight but will also force the display to disable other  
functionalities so that power consumption is further reduced to a minimum. This happens after a specic  
period of time which can be manually adjusted.  
Hibernate can only be enabled on your display when the DPMS mode is enabled rst.  
Therefore, please refer to "DPMS mode", page 22 to do this.  
22  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Advanced operation  
To enable/disable hibernation on your display:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Power Management menu.  
3. Enter the Hibernate submenu.  
4. Select Enabled/Disabled as desired and conrm.  
To specify the hibernate timeout:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Power Management menu.  
3. Enter the Hibernate Timeout submenu.  
4. Set the timeout value as desired and conrm.  
5.12 Luminance target  
About the luminance target  
The luminance target of your Coronis Fusion 6MP is adjustable over a predened range. When you  
change the luminance target, the display will adjust its backlight to reach the target.  
To set the luminance target:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Calibration menu.  
3. Enter the Luminance Target submenu.  
4. Set a luminance target value as desired and conrm.  
The default value is 450 cd/m². The ve year warranty is valid for this setting.  
5.13 Color presets  
About color presets  
The available color preset settings for your display are:  
Clearbase  
Bluebase  
User  
Simulation of the clearbase lm color temperature.  
Simulation of the bluebase lm color temperature.  
When selecting the User color temperature setting,  
you will be able to manually dene the X and Y  
coordinates or the display color temperature in  
separate submenus.  
Native White  
The native, unmodied color temperature of the  
LCD panel.  
To select a color preset:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Calibration > Color Settings menu.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Advanced operation  
3. Enter the Color Presets submenu.  
4. Select one of the available Color Presets and conrm.  
5.14 Color temperature  
About color temperature:  
It is possible to change the color temperature of your display.  
Color temperature can only be changed on your display when color presets is set to  
user. Therefore, please refer to "Color presets", page 23 to do this.  
To change the color temperature:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Calibration > Color Settings menu.  
3. Enter the Color Denition submenu.  
4. Select Color Temperature and conrm.  
5. Enter the Color Temperature submenu.  
6. Set the Temperature value as desired and conrm.  
5.15 Color coordinates  
About color coordinates:  
It is possible to change the color coordinates of your display.  
Color coordinates can only be changed on your display when color presets is set to  
user. Therefore, please refer to "Color presets", page 23 to do this.  
To change the color coordinates:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Calibration > Color Settings menu.  
3. Enter the Color Denition submenu.  
4. Select Color Coordinates and conrm.  
5. Enter the X and/or Y submenu.  
6. Set the coordinate value for X and/or Y as desired and conrm.  
5.16 Viewing modes  
About viewing modes  
The Coronis Fusion 6MP can be used in two viewing modes:  
24  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5. Advanced operation  
Diagnostic  
Text  
This mode provides the full calibrated luminance  
and is intended for using the display for diagnostic  
purposes.  
In this mode, the luminance is reduced to  
approximately half of the luminance. This  
is intended for using the display with ofce  
applications such as word processing.  
Please note that text mode is not persistent, once  
powered off, the unit will restart in diagnostic mode.  
As the Coronis Fusion 6MP is intended to be used in a diagnostic environment, the di-  
agnostic mode should always be selected.  
To select a viewing mode:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Calibration menu.  
3. Enter the Viewing Mode submenu.  
4. Select Diagnostic/Text as desired and conrm.  
5.17 Display functions  
About display functions  
Native, uncorrected panels will display all grayscale/color levels with luminance increments that are not  
optimal for crucial diagnostic information. Studies have shown however, that in medical images certain  
grayscale/color parts contain more diagnostic information then others. To respond to these conclusions,  
display functions have been dened. These functions emphasize on these parts containing crucial diag-  
nostic information by correcting the native panel behavior.  
Native  
If you select Native, the native panel behavior will  
not be corrected.  
Dynamic Gamma 1.8  
Dynamic Gamma 2.2  
These are gamma functions that are shifted to take  
into account the non-zero luminance of an LCD  
panel when driven with a “black” signal. They are  
especially useful in CT applications to improve the  
perception of low Hounseld values.  
DICOM  
DICOM (Digital Imaging and Communications  
in Medicine) is an international standard that  
was developed to improve the quality and  
communication of digital images in radiology.  
In short, the DICOM display function results in  
more visible grayscales in the images. Barco  
recommends selecting the DICOM display function  
for most medical viewing applications.  
User  
This display function will be automatically selected  
when display functions are dened by MediCal  
QAWeb.  
Gamma 1.8  
Gamma 2.2  
Select one of these display functions in case the  
display is to replace a CRT display with a gamma  
of 1.8 or 2.2 respectively.  
To select a display function:  
1. Bring up the OSD main menu.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5. Advanced operation  
2. Navigate to the Conguration > Calibration menu.  
3. Enter the Display Function submenu.  
4. Select one of the available display functions and conrm.  
5.18 Ambient Light Compensation (ALC)  
About ALC  
Ambient Light Compensation (ALC) can only be enabled on your display when the DI-  
COM display function is selected. Therefore, please refer to "Display functions", page  
25 to correctly set the display function.  
When ALC is enabled, the DICOM display function will be recalculated taking a preset ambient light cor-  
rection value into account. This value is determined by the selected reading room. Therefore, it is also  
important to select a realistic reading room when enabling ALC. This can be done by following the instruc-  
To enable/disable ALC:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Calibration > Ambient Light menu.  
3. Enter the Ambient Light Compensation submenu.  
4. Select Enabled/Disabled as desired and conrm.  
5.19 Reading rooms  
About reading rooms  
Reading rooms can only be selected when the DICOM display function is selected.  
Therefore, please refer to "Display functions", page 25 to correctly set the display  
function.  
The American Association of Physicists in Medicine (AAPM) composed a list of pre-dened reading rooms.  
Each of these reading rooms are dened by following parameters:  
the maximum light allowed in this type of room  
the preset ambient light correction value for this reading room  
These parameters are stored in your display and determine the preset ambient light correction value to  
take into account to recalculate the DICOM display function when Ambient Light Compensation (ALC) is  
enabled. Please refer to "Ambient Light Compensation (ALC)", page 26 to enable ALC.  
The available reading rooms for your Coronis Fusion 6MP are:  
CR/DR/ MAMMO  
CT/MR/NM  
Corresponds to light conditions in diagnostic  
reading rooms for computed radiology, digital  
radiology or mammography. This setting has the  
lowest maximum ambient light.  
Corresponds to light conditions in diagnostic  
reading rooms for computed tomography, magnetic  
resonance or nuclear medicine scans.  
26  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Advanced operation  
Staff Ofce  
Corresponds to light conditions in ofce rooms.  
Clinical Viewing Room  
Corresponds to light conditions in diagnostic  
reading rooms for clinical viewing.  
Emergency Room  
Operating Room  
Corresponds to light conditions in emergency  
rooms.  
Corresponds to light conditions in operating rooms.  
This setting has the highest maximum ambient light.  
To select a reading room:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Calibration > Ambient Light menu.  
3. Enter the Reading Room submenu.  
4. Select one of the available reading rooms and conrm.  
5.20 Continuous ALC  
About Continuous ALC  
Continuous ALC can only be selected when the DICOM display function is selected.  
Therefore, please refer to "Display functions", page 25 to correctly set the display func-  
tion.  
Enabling continuous ALC will continuously recalculate the DICOM display function taking the averaged  
ambient light into account.  
To select continuous ALC:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Calibration > Ambient Light menu.  
3. Enter the Continuous ALC submenu.  
4. Select Enabled/Disabled as desired and conrm.  
5.21 Image scaling  
About image scaling  
Enabling image scaling will multiply each individual pixel to one or more adjacent pixels so that the size  
of the displayed image will be a multiple of the original image source video input signal.  
Image scaling is only possible when the resolution of your display’s video input signal  
is less than or equal to half the maximum resolution of the display.  
To enable/disable image scaling:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Image Source menu.  
3. Enter the Scaling submenu.  
4. Select Enabled/Disabled as desired and conrm.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Advanced operation  
5.22 Image source selection modes  
About image source selection modes  
Your Coronis Fusion 6MP automatically detects the number of video input signals connected, attaches  
them to the correct display side and applies the correct video settings to it (resolution, video encoding  
mode, refresh rate,...). However, it may be needed to manually select the video input signal(s) to be  
displayed on a certain display side or to adjust certain video settings yourself. The start to this is selecting  
one of the following image source selection modes available for your display:  
Automatic  
In this mode, your display automatically detects the  
connected video input signals, attaches them to the  
correct display side and applies the correct video  
settings to it (resolution, video encoding mode,  
refresh rate,...). No video settings are available  
when this mode is selected.  
One Image Source  
Two Image Sources  
This mode is intended for displaying and manually  
conguring only one connected video input signal.  
When selecting this mode, the video settings  
become available for the selected video input  
signal.  
This mode is intended for displaying and manually  
conguring two connected video input signals (one  
on each display side). When selecting this mode,  
the video settings become available for the selected  
video input signal on each side of the display.  
To select an image source selection mode:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Image Sources menu.  
3. Enter the Image Source Selection submenu.  
4. Select one of the available image source selection modes and conrm.  
5.23 Video input signals  
Your Coronis Fusion 6MP display automatically detects the connected video input sig-  
nals. Manually selecting image source video input signals is possible, but then your  
display’s image source selection mode should be set to allow this. Please refer to "Im-  
About input signals  
The available input signals for your display are:  
DisplayPort 1  
The input corresponding to the DisplayPort 1  
connector.  
The input corresponding to the DVI 1 connector.  
DVI 1  
DisplayPort 2  
The input corresponding to the DisplayPort 2  
connector.  
The input corresponding to the DVI 2 connector.  
DVI 2  
Automatic Selection  
The input is automatically selected.  
28  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Advanced operation  
To manually select a video input signal:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Image Sources > (Left/Right) Image Source menu.  
3. Enter the Input Signal submenu.  
4. Select one of the available input signals and conrm.  
5.24 Video encoding modes  
Your Coronis Fusion 6MP display automatically detects the connected video input sig-  
nals and applies the correct video encoding settings. Manually selecting a video encod-  
ing mode is possible, but then your display’s image source selection mode should be  
set to allow this. Please refer to "Image source selection modes", page 28 to do this.  
About video encoding modes  
Video encoding modes specify how the color and luminance information is encoded in the video signal. In  
consumer displays, this is usually done by a limited 8-bit encoding mechanism. Your Coronis Fusion 6MP  
however, features 10-bit encoding enabling it to better match the DICOM dened grayscale range. Such  
an extensive range is necessary to comply with the guidelines set forward by the latest medical guidelines.  
The available video encoding modes for your display are listed below.  
Please note that the display controller connected to your display might not always sup-  
port all these video encoding modes.  
Standard  
HDR1  
This mode uses the standard 8 bit encoding  
mechanism.  
This mode features 10-bit video encoding following  
the High Dynamic Range (HDR) standard, usually  
used on color displays.  
HDR2  
HDR2 is a Barco specic mode featuring 10-bit  
video encoding following the High Dynamic Range  
(HDR) standard but allowing full refresh rate (which  
is not always possible with HDR1). This mode is  
usually used on color displays.  
Dual 10 (only with Barco display controller)  
Automatic  
Dual 10 is a Barco specic 10-bit video encoding  
mode which is usually used on grayscale displays  
and which allows full refresh rate.  
When selecting this option, your Coronis Fusion  
6MP will automatically assign the correct video  
encoding settings to the connected video input  
signals.  
To manually select a video encoding mode:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Image Sources > (Left/Right) Image Source menu.  
3. Enter the Video Encoding submenu.  
4. Select one of the available video encoding modes and conrm.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5. Advanced operation  
5.25 Grayscale conversion modes  
Your Coronis Fusion 6MP display automatically detects the connected video input  
signals and applies the correct grayscale conversion settings. Manually selecting a  
grayscale conversion mode is possible, but then your display’s image source selection  
mode should be set to allow this. Please refer to "Image source selection modes",  
page 28 to do this.  
About grayscale conversion modes  
Grayscale conversion modes specify how color generated on the display controller is converted to  
grayscale in your display.  
The available grayscale conversion modes are:  
No Conversion  
Use Red Channel  
Use Green Channel  
Use Blue Channel  
Use All Channels  
This mode is intended for grayscale displays where  
gray is sent over the red channel.  
This mode is intended for grayscale displays where  
gray is sent over the green channel.  
This mode is intended for grayscale displays where  
gray is sent over the blue channel.  
This mode is intended for grayscale displays where  
gray is sent over the red, green and blue channel.  
This is done by means of a standard conversion  
mechanism where 30% red, 59% green and 11%  
blue are used to generate gray.  
To manually select a grayscale conversion mode:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Image Sources > (Left/Right) Image Source menu.  
3. Enter the Grayscale Conversion submenu.  
4. Select one of the available color conversion modes and conrm.  
5.26 EDID timings  
Your Coronis Fusion 6MP display automatically detects the connected video input sig-  
nals and applies the correct timings. Manually conguring the EDID timings is possible,  
but then your display’s image source selection mode should be set to allow this. Please  
About EDID timings  
Following EDID timings are available for your Coronis Fusion 6MP:  
Resolution  
Allows to manually modify the resolution of the  
image source video input signal.  
Refresh Rate  
Allows to manually select the refresh rate of the  
image source video input signal depending on the  
maximum refresh rate of the display controller  
connected to your display.  
Color Depth  
Allows to change the color depth to 8 or to 10 bit.  
30  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Advanced operation  
To manually set EDID timings:  
1. Bring up the OSD main menu.  
2. Navigate to the Conguration > Image Sources > (Left/Right) Image Source menu.  
3. Enter the Timings submenu.  
4. Select Resolution, Refresh Rate or Color Depth.  
5. Select one of the available settings and conrm.  
5.27 Display info  
About display info  
Your display serial number, color type, native resolution, rmware versions, etc. are available in a dedi-  
cated submenu of the OSD menu.  
To retrieve info about your display:  
1. Bring up the OSD main menu.  
2. Navigate to the About this Display menu to make the information visible on the screen.  
5.28 Display status  
About display status  
The Status submenu of the OSD menu provides info on the current status of your display (runtimes, tem-  
peratures, etc.), the status of the connected image sources (video encoding mode, timings, etc.), the  
current calibration status of your display (display function, luminance, ALC, etc.) and the status about  
activated connections.  
To retrieve the status of your display:  
1. Bring up the OSD main menu.  
2. Navigate to the Status menu.  
3. Enter the Display, Image Sources, Calibration or Connectivity submenu as desired.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Advanced operation  
32  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Cleaning your display  
6. CLEANING YOUR DISPLAY  
6.1 Cleaning instructions  
To clean the display  
Clean the display using a sponge, cleaning cloth or soft tissue, lightly moistened with a recognized clean-  
ing product for medical equipment. Read and follow all label instructions on the cleaning product. In case  
of doubt about a certain cleaning product, use plain water.  
Do not use following products:  
Alcohol/solvents at higher concentration > 5%  
Strong alkalis lye, strong solvents  
Acid  
Detergents with uoride  
Detergents with ammonia  
Detergents with abrasives  
Steel wool  
Sponge with abrasives  
Steel blades  
Cloth with steel thread  
CAUTION: Take care not to damage or scratch the front glass or LCD. Be careful with  
rings or other jewelry and do not apply excessive pressure on the front glass or LCD.  
CAUTION: Do not apply or spray liquid directly to the display as excess liquid may cause  
damage to internal electronics. Instead, apply the liquid to a cleaning cloth.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
6. Cleaning your display  
34  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Repackaging instructions  
7. REPACKAGING INSTRUCTIONS  
Overview of the packaging  
8
7
6
5
4
3
2
1
Image 7-1  
Box  
Coronis Fusion 6MP display  
Top buffer  
1
2
5
6
System CD + User guide  
K5902055 CORONIS FUSION 6MP 28/08/2013  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7. Repackaging instructions  
Bottom buffer  
Power supply  
Display controller box  
3
4
7
8
Cables (video, USB, power)  
7.1 Repacking your display  
How to repack your display  
1. Place the empty box on a stable surface.  
2. Slide the system CD and user guide in the dedicated bag attached at the inside of the box.  
3. Place the bottom buffer in the box.  
4. Put the power supply in the dedicated cavity of the bottom buffer.  
5. Put the Coronis Fusion 6MP display in its original bag and place it in the box with its panel facing  
downwards.  
6. Put the top buffer on top of the display.  
7. When applicable, slide the display controller box in the dedicated cavity of the buffers.  
8. Put all cables (video, USB, power) in their original bag and slide them in the dedicated cavity of the  
buffers.  
9. Close and seal the box.  
36  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Important information  
8. IMPORTANT INFORMATION  
8.1 Safety information  
General recommendations  
Read the safety and operating instructions before operating the device.  
Retain safety and operating instructions for future reference.  
Adhere to all warnings on the device and in the operating instructions manual.  
Follow all instructions for operation and use.  
Electrical Shock  
Do not modify this equipment without authorization of the manufacturer.  
No user-serviceable part inside. The equipment should be opened only by qualied service personnel.  
Type of protection (electrical):  
Display with external power supply: Class I equipment.  
Degree of safety (ammable anesthetic mixture):  
Equipment not suitable for use in the presence of a ammable anesthetic mixture with air or with oxygen  
or nitrous oxide.  
Non-patient care equipment  
Equipment primarily for use in a health care facility that is intended for use where contact with a patient  
is unlikely (no applied part).  
The equipment may not be used with life support equipment.  
The user should not touch the equipment, nor its signal input/output ports and the patient at the same  
time.  
Power connection – Equipment with external 24 VDC power supply  
Power requirements: The equipment must be powered using the delivered medical approved 24 VDC  
) SELV power supply.  
The medical approved DC (  
(
) power supply must be powered by the AC mains voltage.  
The power supply is specied as a part of the ME equipment or combination is specied as a ME  
system.  
To avoid the risk of electric shock, this equipment must only be connected to a supply mains with  
protective earth.  
The equipment should be installed near an easily accessible outlet.  
The equipment is intended for continuous operation.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
8. Important information  
Transient over-voltage  
If the device is not used for a long time, disconnect it from the AC inlet to avoid damage by transient  
over-voltage.  
To fully disengage the power to the device, please disconnect the power cord from the AC inlet.  
Power cords:  
Utilize a UL-listed detachable power cord, 3-wire, type SJ or equivalent, 18 AWG min., rated 250 V  
min., provided with a hospital-grade type plug 5-15P conguration for 120V application, or 6-15P for  
240V application.  
Do not overload wall outlets and extension cords as this may result in re or electric shock.  
Mains lead protection (U.S.: Power cord): Power cords should be routed so that they are not likely to  
be walked upon or pinched by items placed upon or against them, paying particular attention to cords  
at plugs and receptacles.  
The power supply cord should be replaced by the designated operator only at all time.  
Water and moisture  
Never expose the device to rain or moisture.  
Never use the device near water - e.g. near a bathtub, washbasin, swimming pool, kitchen sink, laundry  
tub or in a wet basement.  
Ventilation  
Do not cover or block any ventilation openings in the cover of the set. When installing the device in a  
cupboard or another closed location, heed the necessary space between the set and the sides of the  
cupboard.  
Installation  
Place the device on a at, solid and stable surface that can support the weight of at least 3 devices. If you  
use an unstable cart or stand, the device may fall, causing serious injury to a child or adult, and serious  
damage to the device.  
This apparatus conforms to:  
CE0120 (MDD 93/42/EEC; A1:2007/47/EC class IIb product), CE - 2004/108/EC, IEC 60950-1:2005  
+ A1:2009 (2ND EDITION), IEC 60601-1:2005, ANSI/AAMI ES 60601-1:2005 + C1:2009 + A2:2010,  
CAN/CSA C22.2 No. 60601-1 (2008), DEMKO - EN 60601-1:2006, EN 60601-1-2:2007, CCC -  
GB9254-2008 + GB4943.1-2011 + GB17625.1-2012, KCC, VCCI, FCC class B, ICES-001 Level B, FDA  
510(k), RoHS.  
National Scandinavian Deviations for CL. 1.7.2:  
Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan"  
Norway: "Apparatet må tilkoples jordet stikkontakt"  
Sweden: "Apparaten skall anslutas till jordat uttag"  
8.2 Environmental information  
Disposal information (Waste Electrical and Electronic Equipment)  
This symbol on the device indicates that, under European Directive 2002/96/EC governing waste  
from electrical and electronic equipment, this device must not be disposed of with other municipal waste.  
38  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Important information  
Please dispose of your waste device by handing it over to a designated collection point for the recycling of  
waste electrical and electronic equipment. To prevent possible harm to the environment or human health  
from uncontrolled waste disposal, please separate these devices from other types of waste and recycle  
them responsibly to promote the sustainable reuse of material resources.  
For more information about recycling of this device, please contact your local city ofce or your municipal  
waste disposal service. For details, please visit the Barco website at: http://www.barco.com/en/About-  
Barco/weee.  
Turkey RoHS compliance  
Republic of Turkey: In conformity with the EEE Regulation  
Türkiye Cumhuriyeti: EEE Yönetmeliğine Uygundur  
中国大RoHS  
Chinese Mainland RoHS  
根据中国大子信息染控制管理法》(也称中国大RoHS), 以下部分列出了Barco品  
中可能包含的有毒和/或有害物的名称和含量。中国大RoHS指令包含在中国信息产业MCV准:  
子信息品中有毒物的限量要求中。  
According to the “China Administration on Control of Pollution Caused by Electronic Information Products”  
(Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or  
hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in  
the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of  
toxic substances in Electronic Information Products”.  
零件(名称)  
有毒有害物或元素  
Component name  
Hazardous substances and elements  
铬  
溴联苯 多二苯  
Hg  
Pb  
Cd  
Cr6+  
PBB  
PBDE  
x
x
x
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
印制路配件  
Printed Circuit Assemblies  
液晶面板  
o
o
o
o
o
LCD panel  
外接(线)缆  
External Cables  
线路  
Internal wiring  
金属外壳  
Metal enclosure  
塑胶外壳  
Plastic enclosure  
o
x
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
()  
Heatsinks  
源供器  
Power Supply Unit  
扇  
Fan  
K5902055 CORONIS FUSION 6MP 28/08/2013  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Important information  
零件(名称)  
有毒有害物或元素  
Component name  
Hazardous substances and elements  
铬  
溴联苯 多二苯  
Hg  
Pb  
Cd  
Cr6+  
PBB  
PBDE  
o
o
o
o
o
o
o
o
o
o
文件书  
Paper Manuals  
盘说书  
o
o
CD manual  
O: 表示有毒有害物部件所有均材料中的含量均在 SJ/T 11363-2006 定的限量要求以下.  
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for  
this part is below the limit requirement in SJ/T11363-2006.  
X: 表示有毒有害物至少在部件的某一均材料中的含量超出 SJ/T 11363-2006 定的  
限量要求.  
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous  
materials used for this part is above the limit requirement in SJ/T11363-2006  
在中国大陆销售的相应电子信息品(EIP)都必遵照中国大子信息染控制标识要求》准  
保使用期限(EFUP标签Barco品所采用的EFUP标签阅实例,徽内部的号使用于制  
品)基于中国大的《子信息保使用期限通准。  
All Electronic Information Products (EIP) that are sold within Chinese Mainland must comply with the  
“Electronic Information Products Pollution Control Labeling Standard” of Chinese Mainland, marked with  
the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses  
(please refer to the photo) is based on the “Standard of Electronic Information Products Environmental  
Friendly Use Period” of Chinese Mainland.  
10  
8.3 Regulatory compliance information  
Indications for use  
The Coronis Fusion 6MP (MDCC-6230) display is a display device capable of displaying two 3MP display  
images electronically fused together on the one panel. It is intended to be used in displaying and viewing  
digital images for review and analysis by trained medical practitioners. It provides a screen resolution  
of 3280 x 2048 pixels at a pixel pitch of 0.1995mm. This provides the equivalent resolution of 2 x 3MP  
displays.  
The Coronis Fusion 6MP (MDCC-6230) display is not intended for primary diagnosis of Mammography  
images.  
Caution (USA): Federal law restricts this device to sale by or on the order of a physician or a practitioner  
trained on its use.  
40  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Important information  
FCC class B  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  
(1) this device may not cause harmful interference, and (2) this device must accept any interference re-  
ceived, including interference that may cause undesired operation.  
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to  
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. This device generates, uses and can radiate radio frequency  
energy and, if not installed and used in accordance with the instructions, may cause harmful interference  
to radio communications. However, there is no guarantee that interference will not occur in a particular  
installation. If this device does cause harmful interference to radio or television reception, which can be  
determined by turning the device off and on, the user is encouraged to try to correct the interference by  
one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the device and receiver.  
Connect the device into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
Canadian notice  
This ISM device complies with Canadian ICES-001.  
Cet appareil ISM est conforme à la norme NMB-001 du Canada.  
8.4 EMC notice  
General information  
No specic requirement on the use of external cables or other accessories except power supply.  
With the installation of the device, use only the delivered power supply or a spare part provided by the  
legal manufacturer. Using another can result in a decrease of the immunity level of the device.  
Electromagnetic emissions  
The Coronis Fusion 6MP is intended for use in the electromagnetic environment specied below. The  
customer or the user of the Coronis Fusion 6MP should assure that it is used in such an environment.  
Emissions test  
Compliance  
Electromagnetic environment –  
Guidance  
RF emissions  
CISPR 11  
Group 1  
The Coronis Fusion 6MP uses  
RF energy only for its internal  
function. Therefore, its RF  
emissions are very low and are  
not likely to cause any interference  
in nearby electronic equipment.  
The Coronis Fusion 6MP  
RF emissions  
Class B  
Class D  
Complies  
is suitable for use in all  
establishments, including  
CISPR 11  
Harmonic emissions  
domestic establishments and  
those directly connected to the  
public low-voltage power supply  
network that supplies buildings  
used for domestic purposes.  
IEC 61000-3-2  
Voltage uctuations/ icker  
emissions  
IEC 61000-3-3  
This Coronis Fusion 6MP complies with appropriate medical EMC standards on emissions to, and inter-  
ference from surrounding equipment. Operation is subject to the following two conditions: (1) this device  
may not cause harmful interference, and (2) this device must accept any interference received, including  
interference that may cause undesired operation.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Important information  
Interference can be determined by turning the equipment off and on.  
If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding  
equipment, the user is encouraged to try to correct the interference by one or more of the following mea-  
sures:  
Reorient or relocate the receiving antenna or equipment.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced technician for help.  
Electromagnetic immunity  
The Coronis Fusion 6MP is intended for use in the electromagnetic environment specied below. The  
customer or the user of the Coronis Fusion 6MP should assure that it is used in such an environment.  
Immunity test  
IEC 60601  
Test levels  
Compliance level  
Electromagnetic  
environment –  
guidance  
Electrostatic discharge ± 6kV contact  
± 6kV contact  
± 8kV air  
Floors should be wood,  
concrete or ceramic tile.  
If oors are covered with  
synthetic material, the  
relative humidity should  
be at least 30%  
(ESD)  
± 8kV air  
IEC 61000-4-2  
Electrical fast  
transient/burst  
± 2kV for power supply ± 2kV for power supply Mains power quality  
lines  
lines  
should be that of a typical  
commercial or hospital  
environment  
IEC 61000-4-4  
± 1kV for input/ output  
lines  
± 1 kV line(s) to line(s)  
± 1kV for input/ output  
lines  
± 1 kV line(s) to line(s)  
Surge  
Mains power quality  
should be that of a typical  
commercial or hospital  
environment  
IEC61000-4-5  
± 2 kV line(s) to earth  
± 2 kV line(s) to earth  
Voltage dips, short  
< 5% UT 1(> 95% dip in < 5% UT (> 95% dip in Mains power quality  
interruptions and voltage UT) for 0.5 cycle  
variations on power  
UT) for 0.5 cycle  
should by that of a typical  
commercial or hospital  
environment. If the user  
of the Coronis Fusion  
40% UT (60% dip in UT) 40% UT (60% dip in UT)  
supply input lines  
for 5 cycles  
for 5 cycles  
IEC 61000-4-11  
70% UT (30% dip in UT) 70% UT (30% dip in UT) 6MP requires continued  
for 25 cycles  
for 25 cycles  
operation during power  
mains interruptions, it  
is recommended that  
the Coronis Fusion 6MP  
be powered from an  
uninterruptible power  
supply or a battery.  
< 5% UT (>95% dip in  
UT) for 5s  
< 5% UT (>95% dip in  
UT) for 5s  
1. is the a.c. mains voltage prior to application of the test level.  
42  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Important information  
Immunity test  
IEC 60601  
Test levels  
Compliance level  
Electromagnetic  
environment –  
guidance  
Power frequency (50/60 3 A/m  
Not applicable  
Power frequency  
Hz) magnetic eld  
magnetic elds should  
be at levels characteristic  
of a typical location in  
a typical commercial or  
hospital environment.  
Portable and mobile  
RF communications  
equipment should be  
used no closer to any  
part of the Coronis Fusion  
6MP, including cables,  
than the recommended  
separation distance  
calculated from the  
equation applicable  
to the frequency  
IEC 61000-4-8  
Conducted RF  
IEC 61000-4-6  
Radiated RF  
3 Vrms  
3 V  
150 kHz to 80 MHz  
3 V/m  
3 V/m  
IEC 61000-4-3  
80 MHz to 2.5 GHz  
of the transmitter.  
Recommended  
separation distance  
d = 1.2P  
d = 1.2P 80 MHz to 800  
MHz  
d = 2.3P 800 MHz to 2.5  
Ghz  
Where P is the maximum  
output power rating  
of the transmitter in  
watts (W) according  
to the transmitter  
manufacturer and d  
is the recommended  
separation distance in  
meters (m).  
Field strengths from  
xed RF transmitters,  
as determined by an  
electromagnetic site  
survey,2 should be less  
than the compliance  
level in each frequency  
range.3  
Interference may occur in  
the vicinity of equipment  
marked with symbol:  
K5902055 CORONIS FUSION 6MP 28/08/2013  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Important information  
Immunity test  
IEC 60601  
Test levels  
Compliance level  
Electromagnetic  
environment –  
guidance  
At 80 MHz and 800 MHz, the higher frequency range applies.  
These guidelines may not apply in all situations. Electromagnetic propagation is af-  
fected by absorption and reection from structures, objects and people.  
Recommended separation distance  
The Coronis Fusion 6MP is intended for use in an electromagnetic environment in which radiated RF  
disturbances are controlled. The customer of the user of the Coronis Fusion 6MP can help prevent elec-  
tromagnetic interference by maintaining a minimum distance between portable and mobile RF communi-  
cations equipment (transmitters) and the Coronis Fusion 6MP as recommended below, according to the  
maximum output power of the communications equipment.  
Rated maximum output Separation distance according to frequency of transmitter  
power of transmitter 4  
150kHz to 80MHz  
80MHz to 800MHz  
800MHz to 2.5GHz  
W
d=1.2P  
d=1.2P  
d=2.3P  
0.01  
0.1  
1
0.12  
0.12  
0.23  
0.38  
1.2  
3.8  
12  
0.38  
1.2  
3.8  
12  
0.73  
2.3  
7.3  
23  
10  
100  
At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.  
These guidelines may not apply in all situations. Electromagnetic propagation is af-  
fected by absorption and reection form structures, object and people.  
2. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur  
radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic  
environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in  
the location in which the Coronis Fusion 6MP is used exceeds the applicable RF compliance level above, the Coronis Fusion 6MP  
should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as  
re-orienting or relocating the Coronis Fusion 6MP.  
3. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.  
4. For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be  
estimated using the equation applicable to the frequency of the transmitter. Where P is the maximum output power rating of the  
transmitter in watts (W) according to the transmitter manufacturer.  
44  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Important information  
8.5 Explanation of symbols  
Symbols on the device  
On the device or power supply, you may nd the following symbols (nonrestrictive list):  
Indicates compliance with the Directive 93/42/EEC as Class I device  
Indicates compliance with the Directive 93/42/EEC as Class II device  
Indicates compliance with Part 15 of the FCC rules (Class A or Class B)  
Indicates the device is approved according to the UL regulations  
Indicates the device is approved according to the UL regulations for Canada  
and US  
Indicates the device is approved according to the UL Demko regulations  
Indicates the device is approved according to the CCC regulations  
Indicates the device is approved according to the VCCI regulations  
Indicates the device is approved according to the KC regulations  
Indicates the device is approved according to the BSMI regulations  
Indicates the USB connectors on the device  
Indicates the DisplayPort connectors on the device  
Indicates the manufacturing date  
Indicates the temperature limitations for the device to safely operate within specs  
K5902055 CORONIS FUSION 6MP 28/08/2013  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Important information  
Indicates the device serial no.  
Consult the operating instructions  
Indicates this device must not be thrown in the trash but must be recycled,  
according to the European WEEE (Waste Electrical and Electronic Equipment)  
directive  
Indicates Direct Current (DC)  
Indicates Alternating Current (AC)  
8.6 Legal disclaimer  
Disclaimer notice  
Although every attempt has been made to achieve technical accuracy in this document, we assume no  
responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable  
documentation possible; if you discover errors, please let us know.  
Barco software products are the property of Barco. They are distributed under copyright by Barco N.V. or  
Barco, Inc., for use only under the specic terms of a software license agreement between Barco N.V. or  
Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any  
form, is authorized.  
The specications of Barco products are subject to change without notice.  
Trademarks  
All trademarks and registered trademarks are property of their respective owners.  
Copyright notice  
This document is copyrighted. All rights are reserved. Neither this document, nor any part of it, may  
be reproduced or copied in any form or by any means - graphical, electronic, or mechanical including  
photocopying, taping or information storage and retrieval systems - without written permission of Barco.  
© 2013 Barco N.V. All rights reserved.  
Patent information (EXAMPLE)  
This product is covered under the following intellectual property rights:  
US Patent RE43,707  
US Patent 7,038,186  
US Patent 7,166,829  
US Patent 6,950,098  
European Patent 1 274 066.  
46  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Important information  
8.7 Technical specications  
Overview  
Product acronym  
MDCC-6230  
Screen technology  
TFT AM Color LCD Dual Domain IPS-Pro  
Active screen size (diagonal) 772 mm (30.4")  
Active screen size (H x V)  
Aspect ratio (H:V)  
Resolution  
654 x 409 mm (25.8 x 16.1")  
16:10  
native 6MP (3280 x 2048)  
congurable to 2 x 3MP+ (1640 X 2048)  
congurable to 2 x 3MP (1536 X 2048)  
Pixel pitch  
0.1995 mm  
Color imaging  
Gray imaging  
Color support  
Viewing angle (H, V)  
Yes  
Yes  
30 bit  
178°  
Uniform Luminance  
Technology (ULT)  
Yes  
Per Pixel Uniformity (PPU)  
No  
Ambient Light Compensation Yes  
(ALC)  
Backlight Output Stabilization Yes (2x)  
(BLOS)  
I-Guard  
Yes  
Maximum luminance  
720 cd/m²  
DICOM calibrated luminance 500 cd/m²  
(ULT off)  
Contrast ratio (typical)  
Response time (Tr + Tf)  
Scanning frequency (H; V)  
Housing color  
1000:1 (panel typical)  
18 ms  
30-150 kHz; 15-80 Hz  
Black / Silver  
Video input signals  
Video inout terminals  
USB ports  
DVI-D Dual Link (2x), DisplayPort (2x)  
NA  
1 upstream (endpoint), 3 downstream  
2.0  
USB standard  
Power requirements (nominal) 100-240V  
Power consumption (nominal) 125W  
Power save mode  
Power management  
Dot clock  
Yes  
DVI-DMPM, DP-DMPM  
280 MHz  
OSD languages  
English, German, French, Dutch, Spanish, Italian, Portugese, Polish,  
Russian, Swedish, Chinese (simplied), Japanese, Korean, Arabic  
Dimensions with stand (W x H Portrait: NA Landscape: 731 x 580~676 x 265 mm  
x D)  
Dimensions w/o stand (W x H Portrait: NA Landscape: 731 x 485 x 141 mm  
x D)  
Dimensions packaged (W x H 869 x 764 x 400 mm  
x D)  
Net weight with stand  
26.5 kg  
K5902055 CORONIS FUSION 6MP 28/08/2013  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Important information  
Net weight w/o stand  
20 kg  
Net weight packaged with  
stand  
36.5 kg  
Net weight packaged w/o stand N/A  
Height adjustment range  
Tilt  
96 mm  
-5° / +25°  
Swivel  
-45° / +45°  
Pivot  
N/A  
Mounting standard  
Screen protection  
Recommended modalities  
Certications  
VESA (100 mm)  
Protective, non-reective glass cover  
CT, MR, US, DR, CR, NM, Film  
CE0120 (MDD 93/42/EEC; A1:2007/47/EC class IIb product), CE -  
2004/108/EC, IEC 60950-1:2005 + A1:2009 (2ND EDITION), IEC  
60601-1:2005, ANSI/AAMI ES 60601-1:2005 + C1:2009 + A2:2010,  
CAN/CSA C22.2 No. 60601-1 (2008), DEMKO - EN 60601-1:2006,  
EN 60601-1-2:2007, CCC - GB9254-2008 + GB4943.1-2011 +  
GB17625.1-2012, KCC, VCCI, FCC class B, ICES-001 Level B, FDA  
510(k), RoHS.  
Supplied accessories  
User Guide  
Quick Installation Sheet  
Video cables (2x DVI Dual Link, 2x DisplayPort)  
Main cables (UK, European (CEBEC/KEMA), USA (UL/ CSA; adaptor  
plug NEMA 5-15P), Chinese (CCC))  
USB 2.0 cable  
External power supply  
Optional accessories  
QA software  
None  
MediCal QAWeb  
Units per pallet  
NA  
Pallet dimensions (W x H)  
Warranty  
NA  
5 years  
Operating temperature  
Storage temperature  
Operating humidity  
Storage humidity  
0°C to 35°C (15°C to 30°C within specs)  
-20°C to 60°C  
8% - 80% (non-condensing)  
5% - 95% (non-condensing)  
Operation altitude  
3000 m  
8.8 Open source license information  
Open source license information  
Open source license usage  
This product contains software components released under an Open Source license. A copy of the source  
code is available on request by contacting your Barco customer support representative.  
EACH SEPARATE OPEN SOURCE SOFTWARE COMPONENT AND ANY RELATED DOCUMENTA-  
TION ARE PROVIDED "AS IS" WITHOUT EXPRESS OR IMPLIED WARRANTY INCLUDING, BUT NOT  
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU-  
LAR PURPOSE. IN NO EVENT SHALL THE COPYRIGHTHOLDER OR ANY OTHER CONTRIBUTOR  
BE LIABLE FOR DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE  
48  
K5902055 CORONIS FUSION 6MP 28/08/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Important information  
POSSIBILITY OF SUCH DAMAGES. MORE INFORMATION/DETAILS IS TO BE FOUND IN EACH SPE-  
CIFIC OPEN SOURCE LICENSE.  
Copyright on each Open Source Software component belongs to the respective initial copyright holder,  
each additional contributor and/or their respective assignee(s), as may be identied in the respective doc-  
umentation, source code, README le, or otherwise. You shall not remove or obscure or otherwise alter  
the respective copyrights.  
You acknowledge living up to the conditions of each separate Open Source Software license.  
A list of the Open Source Software components used is available in the applicable EULA, through the  
(customer section of the) Barco website or through other (online) means.  
K5902055 CORONIS FUSION 6MP 28/08/2013  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
K5902055-01  
August 2013  
Barco n.v.  
President Kennedypark 35  
8500 Kortrijk  
Belgium  
0120  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Network Card ISDN Modem User Manual
Abocom Network Card WU5214 User Manual
Acer Computer Monitor AL1713bm User Manual
Agilent Technologies Computer Hardware E5250A User Manual
Agilent Technologies Guitar L4400 User Manual
Aiwa Stereo System NSX TR77 User Manual
Alpine Universal Remote RUE 4190 User Manual
American Standard Bathroom Aids 2649BW User Manual
Audiovox Remote Starter APS 785 User Manual
Behringer Indoor Furnishings LC2412 User Manual