Bakers Pride Oven Microwave Oven VGH Series User Manual

Rotisserie Ventless Hood  
MODEL VGH-Series  
Installation & Operation Manual  
Serial Numbers 195937 and higher  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Table of Contents  
Table of Contents  
Table of Contents........................................................................................................................................1  
Introduction .................................................................................................................................................2  
Safety Precautions....................................................................................................................................2  
Safety Signs and Messages.................................................................................................................2  
Specific Precautions.............................................................................................................................3  
Safe Work Practices.............................................................................................................................3  
ETL Information ........................................................................................................................................5  
Installation ...................................................................................................................................................6  
Unpacking and Handling...........................................................................................................................6  
Inspection for Shipping Damage ..........................................................................................................6  
Location and Clearance .......................................................................................................................6  
Detailed Installation Instructions...............................................................................................................6  
Wiring ...................................................................................................................................................7  
Baffle Grease / Odor Filter ...................................................................................................................8  
Operation .....................................................................................................................................................9  
Principles of Operation .............................................................................................................................9  
Controls and Indicators.............................................................................................................................9  
Preparation .............................................................................................................................................10  
Start-Up...................................................................................................................................................10  
Shut-Down ..............................................................................................................................................10  
When to Replace the Filter .....................................................................................................................10  
Cleaning..................................................................................................................................................11  
Maintenance ..............................................................................................................................................12  
Scheduled Maintenance .........................................................................................................................12  
Cleaning the Grease Baffle ................................................................................................................13  
Replacing the Charcoal/Odor Filter....................................................................................................13  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Introduction  
Introduction  
Congratulations! You have chosen BKI’s Rotisserie Ventless Global Hood (VGH) system, a state-of-the-  
art unit that filters grease laden air and returns it to the room.  
The VGH is a simple ventless extraction hood system designed to mount on top of VGG model rotisserie  
ovens manufactured by BKI. The hood may be shipped on top of new units or retrofitted at a store  
location. The VGH-5 is designed for use on the VGG-5; while the VGH-8 is designed for use on VGG-8’s  
and VGG-16’s. The hood does not employ and is not designed as a fire suppression system. The  
purpose of the hood is to limit the emission of grease laden air drawn out of or rising above the rotisserie  
oven. Pass thru and solid back versions are available.  
The BKI name and trademark on this unit assures you of the finest in design and engineering -- that it has  
been built with care and dedication -- using the best materials available. Attention to the operating  
instructions regarding proper operation, installation and maintenance will result in long lasting  
dependability to insure the highest profitable return on your investment.  
PLEASE READ THIS ENTIRE MANUAL BEFORE OPERATING THE UNIT. If you  
have any questions, please contact your BKI Distributor. If they do not answer  
your questions, contact the BKI Technical Service Department, toll free: 1-800-  
927-6887. Outside the U.S., call 1-864-963-3471.  
Safety Precautions  
Always follow recommended safety precautions listed in this manual. Below is the safety alert symbol.  
When you see this symbol on your equipment, be alert to the potential for personal injury or property  
damage.  
Safety Signs and Messages  
The following Safety signs and messages are placed in this manual to provide instructions and identify  
specific areas where potential hazards exist and special precautions should be taken. Know and  
understand the meaning of these instructions, signs, and messages. Damage to the equipment, death or  
serious injury to you or other persons may result if these messages are not followed.  
This message indicates an imminently hazardous situation, which, if not avoided,  
will result in death or serious injury.  
This message indicates a potentially hazardous situation, which, if not avoided,  
could result in death or serious injury.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Introduction  
This message indicates a potentially hazardous situation, which, if not avoided,  
may result in minor or moderate injury. It may also be used to alert against  
unsafe practices.  
This message is used when special information, instructions or identification are  
required relating to procedures, equipment, tools, capacities and other special  
data.  
Specific Precautions  
Carbon monoxide poisoning will result from using this hood with any appliance  
that utilizes combustible fuel. Use only electrical appliances with this hood.  
In the event of an appliance fire, serious injury, property damage or death could  
occur if the appliance is not properly placed on top of the rotisserie. The hood  
has not been secured by fasteners. To ensure that the appliance remains in the  
proper position on top of the rotisserie hood during normal operation, DO NOT  
TIP, PULL, OR PUSH APPLIANCE WITHOUT PROVIDING ADEQUATE  
PRECAUTION!  
Hood failure could result if the hood is operated without the grease baffle and  
particle/odor filter installed. This is a special filter designed for this application  
only; other filters will not work properly. Use only a BKI particle/odor filter.  
Safe Work Practices  
Beware of High Voltage  
This equipment uses high voltage. Serious injury can occur if you or  
any untrained or unauthorized person installs, services, or repairs this  
equipment. Always Use an Authorized Service agent to Service Your  
Equipment  
Keep this manual with the Equipment  
This manual is an important part of your equipment. Always keep it  
near for easy access. If you need to replace this manual, contact:  
BKI  
Technical Services Department  
P.O. Box 80400  
Simpsonville, S.C. 29680-0400  
Or call toll free: 1-800-927-6887  
Outside the U.S., call 864-963-3471  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Introduction  
Protect Children  
Keep children away from this equipment. Children may not understand  
that this equipment is dangerous for them and others.  
NEVER allow children to play near or operate your equipment.  
Keep Safety Labels Clean and in Good  
Condition  
Do not remove or cover any safety labels on your equipment. Keep all  
safety labels clean and in good condition. Replace any damaged or  
missing safety labels.  
If you need new safety labels, contact:  
BKI  
Technical Services Department  
P.O. Box 80400  
Simpsonville, S.C. 29680-0400  
Or call toll free: 1-800-927-6887  
Outside the U.S., call 864-963-3471  
Prepare for Emergencies  
Be prepared for fires, injuries, or other emergencies.  
Keep a first aid kit and a fire extinguisher near the equipment. You  
must use a 40-pound Type BC fire extinguisher and keep it within 25  
feet of your equipment.  
911  
Keep emergency numbers for doctors, ambulance services, hospitals,  
and the fire departments near your telephone.  
Know your responsibility as an Employer  
Make certain your employees know how to operate the equipment.  
Make certain your employees are aware of the safety precautions  
on the equipment and in this manual.  
Make certain that you have thoroughly trained your employees  
about operating the equipment safely.  
Make certain the equipment is in proper working condition. If you  
make unauthorized modifications to the equipment, you will reduce  
the safety and function of the equipment.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
ETL Information  
Failure to adhere to building, fire and electrical codes during installation of this unit  
could result in death, serious injury or property damage. The authority having  
jurisdiction, such as the local building inspector or fire marshal, should be  
consulted prior to installation to insure compliance with applicable codes.  
In the event of an appliance fire, serious injury, property damage or death could  
occur if the appliance is powered from a source other than the rotisserie for which  
it is designed for. The hood used on top of the appliance MUST receive its input  
power from the appliance. This hood has not been installed with Fire Extinguishing  
System.  
This filter hood is an Intertek Testing Services, inc. classified ductless hood for  
use with ETL listed type commercial cooking appliance only (rotisserie).  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Installation  
Installation  
Unpacking and Handling  
Inspection for Shipping Damage  
YOU are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates  
for damage as soon as they arrive. If damage to cartons or pallets is found, or if a shortage is found, note  
this on the bill of lading (all copies) prior to signing and receiving.  
If damage is found when the equipment is opened, immediately call the delivering truck line and follow up  
the call with a written report indicating concealed damage to your shipment. Ask for an immediate  
inspection of your concealed damage item. Packaging material MUST be retained to show the inspector  
from the shipping line.  
Location and Clearance  
Make sure the rotisserie is mounted on a level surface capable of supporting the fully loaded oven. Refer  
to oven installation guidelines in the oven manual.  
The hood will be installed in one of two ways. New VGG’s may be ordered with the hood already  
assembled (mounted to the top of the Rotisserie) or shipped with it for installation at the store location.  
VGG’s already in service may be fitted with the hood at a store location as a retro-fit installation.  
Disconnect VGG rotisserie from the electrical supply before attempting  
installation. VGH-8 Hood for use only with BKI Models VGG-8 or VGG-16  
rotisseries.  
VGH-5 Hood for use only with BKI Model VGG-5 rotisserie.  
Detailed Installation Instructions  
1.  
2.  
Remove side panel on the control side of the VGG and both side panels on the VGH.  
Unscrew the 4 philips head screws of the access plate on the ceiling of the VGG and turn it  
around allowing hole to access the VGG control compartment. Reattach the plate with the 4  
philips head screws.  
3.  
4.  
Install the F0155 bushing provided into access hole of VGG.  
Attach 1 of the FB68943018 (Appliance Lifting/Installation Bracket) handles on each side of  
the VGH using the bottom two holes that the side panels attach to and with screws removed  
from the side panels.  
The hood lifting/installation brackets (FB68943018) are used as lifting  
mechanism and are attached to the sides of the hood with side panels removed  
for placing the hood on top of the oven. Failure to install this part could cause  
damage to the hood and/or oven.  
5.  
Pick up and place the VGH on the VGG making sure the controls are on the same side as the  
VGG controls.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Installation  
Wiring  
Electrocution, equipment failure or property damage could result if an unlicensed  
electrician performs the electrical installation. Ensure that a licensed electrician  
perform the electrical installation.  
In the event of an appliance fire, serious injury, property damage or death could  
occur if the appliance is powered from a source other than the oven. The hood  
MUST receive its input power from the rotisserie for which it is mounted on.  
1.  
2.  
Feed power wires and interlock wires through access hole into VGG.  
The power wires # 14, 15, and ground are wired as follows:  
3 phase, 3 wire  
3 phase, 4 wire  
3.  
4.  
For interlock, remove #5 wire from VGG Power Switch. Crimp male connector provided with  
VGH onto #5 wire and plug into female connector of VGH wire #11. Place VGH wire #10 into  
VGG Power Switch where #5 wire was.  
Replace all side panels.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Baffle Grease / Odor Filter  
These filters will come already installed in the hood. If not, follow the steps below to install the filters.  
1. Remove the filter(s) from the plastic bag.  
2. Open the hood and filters doors on the front of the unit by pulling on the handles.  
3. Observing the “FRONT” marking on the grease filter and facing the control side of the hood away  
from the blower, slide the filter into the unit as shown. Repeat for the Charcoal filter with the  
“ARROW” mark showing air flow direction pointing towards the blower.  
4. Close the filters and hood doors.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Operation  
Operation  
Principles of Operation  
The hood requires a VGG rotisserie power supply, a two-wire connections tapped into the control circuits  
of the VGG it is mounted to, and the activation of a simple On / Off switch to operate. The wiring change  
to the VGG ensures that the rotisserie is inoperable until the filter and door switch circuits are satisfied  
(that is, the filters are present and the door(s) are closed).  
A blower inside the ventless hood draws cooking vapors through a grease baffle. Inside the baffle, the air  
reverses direction two times capturing particles of moisture, grease, and dirt. Material collecting on the  
baffle drains into the condensation trough located below the baffle. After air passes through the baffle, it  
then enters a charcoal odor filter. The charcoal odor filter helps to remove cooking odors from the air. The  
filtered air then passes through the blower and is returned to the room.  
The VGG oven may now be energized and operated normally. Refer to the Rotisserie manual on  
operations of the VGG. If a hood door is opened, the ”Door Latch” pilot light illuminates and a relay opens  
the control circuit in the VGG causing the VGG to immediately power off. If either filter is removed, the  
“Check Filters” pilot light illuminates and neither the hood or VGG will operate.  
Controls and Indicators  
1
2
3
4
Item Label  
Description  
Function  
1
2
3
Replace Filters  
Light Indicator  
This light illuminates to indicate time to change out the  
old filters to new ones.  
Check Filters  
Door Latch  
Light Indicator  
Light Indicator  
This light illuminates if either of the two filters or both  
are not in place. The hood will not run with this light on.  
This light illuminates if either of the hood front or rear  
glass door or both is open. The hood will not run if this  
light is on.  
4
Power (0/1)  
Main Power  
Switch / Light  
Indicator  
Turns power to the entire unit ON (1) or OFF (0).  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Operation  
Preparation  
The following conditions must be met for the Filter Hood to function:  
The charcoal odor filter must be installed.  
The grease baffle must be installed.  
The filters door and hood doors must be shut.  
Power must be supplied to the hood from the VGG.  
Start-Up  
To start the Filter Hood, press the power “On / Off” rocker switch button to position I.  
Shut-Down  
Power to the appliance is turned off, when the hood is turned off.  
For proper operation, always turn off appliance and allow time for it to cool before  
turning off the filter hood. This will insure proper capture of grease vapors.  
To stop the Filter Hood, press the power “On / Off” rocker switch button to 0.  
When to Replace the Filter  
The vacuum switch is designed to monitor the level of negative/static pressure created by the blower.  
When the charcoal filter is approximately 70% dirty, the “Replace Filters” pilot light illuminates. This light is  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Operation  
an indication to the operators that the filter needs to be changed soon. Theoretically, the hood may be  
operated with 100% dirty filter (however, hood performance will be affected), as the hood is not designed  
to shut-down with dirty filters.  
In low to medium volume applications, the charcoal filter may need replacement prior to the REPLACE  
FILTERS light illuminating. If you smell a strong odor coming from the face of the filter and the REPLACE  
FILTERS light is not illuminated, the filter needs to be replaced. If necessary, refer to the procedure in this  
manual for replacing the filters (see page 13).  
Cleaning  
Refer to scheduled maintenance in this manual (see page 12).  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Maintenance  
Maintenance  
Electrocution could occur if this unit is hosed down with water. This unit is NOT  
designed for hose wash-down cleaning! Refer to scheduled maintenance below  
for proper hood cleaning.  
Electrocution could occur if power is not removed from this unit before servicing.  
Remove power at disconnect or circuit breaker BEFORE servicing hood.  
Scheduled Maintenance  
Use the following table to help manage scheduled maintenance activities.  
FREQUENCY PERFORMED BY  
PART  
ACTIVITY  
Daily  
User  
User  
User  
Entire Hood  
Wipe unit down with a soft rag and mild  
cleaning agent.  
Condensation  
trough  
Check condensation trough. Empty if  
necessary.  
Grease Baffle  
Clean grease baffle. If necessary, refer  
to the procedure in this manual for  
cleaning the baffle.  
Weekly  
User  
Charcoal/Odor Filter Inspect charcoal/odor filter. In low to  
medium volume applications, the filter  
may need replacement prior to the  
indicating light turning on. This  
condition will be evident by a strong  
odor coming from the face of the filter.  
If necessary, refer to the procedure in  
this manual for replacing the filter.  
Monthly  
User  
Door and Filter  
Interlock  
Check door and filter interlock  
operation. The unit should not operate  
with the front door open or either the  
grease baffle or charcoal/odor filter  
removed. Clean area between grease  
baffle and charcoal/odor filter.  
Injury from rotating fan blades could occur if power is not removed from this unit  
before cleaning the blower section. Remove power at disconnect or circuit breaker  
BEFORE cleaning the blower section.  
3 Months  
User  
Blower Section  
Clean the blower section.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rotisserie Ventless Hood  
Maintenance  
Cleaning the Grease Baffle  
1. Shut down the unit.  
2. Open the front Hood door and Filters door, and slide out the grease baffle from the unit.  
3. Spray the grease baffle with degreasing type soap.  
4. Rinse with hot water; dry, and replace in hood.  
Replacing the Charcoal/Odor Filter  
1. Shut down the unit.  
2. Open the hood door and the filters door on the front of the unit by pulling out on the handles.  
3. Slide the used filter out of the unit.  
4. Remove the replacement filter from the plastic bag.  
5. Observing the “AIR FLOW DIRECTION” mark on the filter, slide the filter into the unit.  
When installing a new filter, slight resistance should be observed as the filter is  
being slid into place. This resistance is generated by flap metal plates located on  
the top of the filter compartment frames. If this resistance is not felt after a period  
of time it may become necessary to adjust the pressure that these plates provide  
by pulling them slightly downwards with your fingers.  
6. Close the doors.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P.O. Box 80400, Simpsonville, S.C. 29680-0400, USA  
Made and printed in the U.S.A  
LI0296/0808  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Network Router 10014303 User Manual
Acer Computer Monitor P221W User Manual
Acer Laptop VDT25V7001 User Manual
ADIC Microscope Magnifier 6 00026 01 Rev A User Manual
ADTRAN Network Card T200 T1 HDSL4 User Manual
Agilent Technologies Portable Generator E4400 90333 User Manual
Aiphone Home Security System AX DVF P User Manual
Altec Lansing Speaker CF404 4T User Manual
Barco MP3 Player R59770263 06 User Manual
BB Electronics Computer Hardware 232CC1A User Manual