BB Electronics Switch EIR505 XX User Manual

Product Description  
Model EIR505-xx  
Documentation Number: EIR505-xx_5107m  
707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA  
Phone (815) 433-5100 -- General Fax (815) 433-5105  
Phone (815) 433-5100 -- General Fax (815) 433-5105  
Sales e-mail: [email protected] -- Fax (815) 433-5109  
Technical Support e-mail: [email protected] -- Fax (815) 433-5104  
European Headquarters  
B&B Electronics  
Westlink Commercial Park -- Oranmore, Co. Galway, Ireland  
Phone +353 91-792444 -- Fax +353 91-792445  
Sales e-mail: [email protected]  
Technical Support e-mail: [email protected]  
B&B Electronics Mfg. Co. Inc. -- December 2007  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Five Port Managed Industrial  
Ethernet Switches  
User Manual  
Manual Documentation Number: EIR505-xx_5107m  
Table of Contents  
iii  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notice  
The contents of this manual are based on the firmware, kernel, and  
hardware versions listed below.  
Firmware Version  
V1.29  
V2.05  
A5.00  
Kernel Version  
Hardware Version  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC Warning  
This Equipment has been tested and found to comply with the limits for a  
Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are  
designed to provide reasonable protection against harmful interference in a  
residential installation. This equipment generates uses and can radiate  
radio frequency energy and, if not installed and used in accordance with the  
instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference to  
radio or television reception, which can be determined by turning the  
equipment off and on, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to  
which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
CE Mark Warning  
This is a Class-A product. In a domestic environment this product may cause  
radio interference in which case the user may be required to take adequate  
measures.  
Manual Documentation Number: EIR505-xx_5107m  
Table of Contents  
v
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Content  
FCC Warning............................................................ v  
CE Mark Warning..................................................... v  
Introduction................................................................ 1  
Features ................................................................... 1  
Package Contents.................................................... 2  
Hardware Description................................................ 3  
Physical Dimension.................................................. 3  
Front Panel............................................................... 3  
Reset Button.......................................................................3  
Bottom View............................................................. 4  
DIP-switch ................................................................ 4  
LED Indicators.......................................................... 5  
Ports......................................................................... 6  
Cabling ..................................................................... 8  
Wiring the Power Inputs ........................................... 9  
Wiring the Fault Alarm Contact ................................ 9  
Wiring the Fault Alarm Contact .............................. 10  
Mounting Installation............................................... 11  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIN-Rail Mounting.................................................. 11  
Wall Mount Plate Mounting .................................... 13  
Hardware Installation............................................... 14  
Network Application................................................ 15  
X-Ring Application.................................................. 15  
Coupling Ring Application...................................... 16  
Dual Homing Application........................................ 17  
Web-Based Management ........................................ 18  
About Web-based Management ............................ 18  
Preparing for Web Management............................ 18  
System Login.......................................................... 19  
Port status .............................................................. 19  
Port status .............................................................. 20  
Single Port Information.....................................................20  
Port Statistics ......................................................... 21  
Port Control ............................................................ 22  
Switch Settings....................................................... 23  
Port Mirroring.......................................................... 24  
VLAN configuration ................................................ 25  
Manual Documentation Number: EIR505-xx_5107M  
Table of Contents  
vii  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port-based VLAN .............................................................25  
802.1Q VLAN ...................................................................27  
IP Address.............................................................. 31  
SNTP Configuration ............................................... 32  
IP Security.............................................................. 35  
RSTP Configuration ............................................... 36  
System Configuration.......................................................36  
Per Port Configuration......................................................38  
X-Ring .................................................................... 39  
QoS Configuration.................................................. 41  
IGMP ...................................................................... 43  
Security Manager ................................................... 45  
Configuration Backup............................................. 45  
TFTP Restore Configuration.............................................45  
TFTP Backup Configuration .............................................46  
TFTP Update Firmware.......................................... 46  
Factory Default....................................................... 47  
System Reboot....................................................... 47  
Save Configuration................................................. 48  
Rate Control ........................................................... 48  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubles shooting.................................................... 50  
Technical Specification........................................... 51  
Manual Documentation Number: EIR505-xx_5107M  
Table of Contents  
ix  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
The Elinx EIR505 series of Industrial Managed Ethernet Switches provide  
powerful functionality in a small package. Designed for industrial  
applications, these switches are highly reliable.  
Features  
Conforms to IEEE 802.3 10Base-T, 802.3u 100Base-TX/100Base-FX  
5-port 10/100TX industrial switch (Fiber Optic models have 1 100FX  
port)  
RJ-45 ports support auto MDI/MDI-X  
Store-and-Forward switching architecture  
Wide-range redundant input power connections  
DIN rail and panel mount design  
Easy to configure  
Web based management  
IEEE 802.1p class of service and port based, Tag based, and Type of  
service priority method  
Each port supports 4 priority queues  
Port based VLAN / 802.1 Q Tag VLAN  
IGMP with Query mode for multi media application  
DHCP client  
Ingress packet filter and egress rate limit.  
Relay alarm output for system events  
Input power reverse polarity protection  
Port mirror for TX only, TX and RX packet  
IEEE 802.3x flow control  
¾
¾
Flow control with full-duplex  
Back pressure with half-duplex  
X-Ring function  
SNTP  
TFTP firmware update, system configuration restore and backup  
1Mbits Embedded memory  
2K MAC address table  
Manual Documentation Number: EIR505-xx_5107m  
1
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Package Contents  
5 Port Managed Industrial Switch  
One DIN-Rail (attached to the switch)  
One Panel mount plate and six screws  
User manual  
5 10/100TX with X-Ring Web Management  
Industrial switch  
User Manual  
Wall Mount Plate  
Screws  
DIN-Rail  
If any item is missing or damaged, contact B&B  
Electronics for a replacement.  
2
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Description  
Physical Dimension  
(W x H x D) 2.13in x 5.31in x 4.13 in (54mm x 135mm x 105mm)  
Front Panel  
EIR505 Front Panel  
Reset Button  
The reset button is used to restart the reboot the switch or restore it to the  
factory default configuration.  
Restart: Press the button for 2 seconds and release.  
Set to factory default value: Press the button for 5 seconds and  
release.  
Manual Documentation Number: EIR505-xx_5107m  
3
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bottom View  
The bottom panel of the EIR-505-xx industrial switch consists of one  
terminal block connector with two DC power inputs and one DC IN power  
jack.  
Bottom Panel of the industrial switch  
DIP-switch  
The six position DIP-switch is used to configure the relay alarm operation  
mode and the master ring operation mode. The default value for each  
position is OFF.  
DIP Switch No  
Status  
Description  
OFF  
Disable port 1 Alarm  
1
2
ON  
Enable port Alarm.  
Disable port Alarm  
OFF  
4
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ON  
Enable port Alarm.  
OFF  
ON  
Disable port Alarm  
Enable port Alarm.  
Disable port Alarm  
Enable port Alarm.  
Disable port Alarm  
3
4
OFF  
ON  
OFF  
5
ON  
Enable port Alarm.  
OFF  
ON  
Disable the master ring function.  
6
Enable the switch as the ring master  
in the X-Ring group.  
LED Indicators  
There are 7 diagnostic LEDs located on the front panel. They provide  
real-time status information.  
LED  
Status  
Meaning  
Power  
Green  
The switch is on  
Manual Documentation Number: EIR505-xx_5107m  
5
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The switch is off or no power input  
is available  
Off  
The switch is the master of X-Ring  
group  
Green  
Off  
R.M. (Ring Master)  
The industrial switch is not the  
master of an X-Ring group  
Green  
Off  
Power source 1 is available  
Power source 1 is not available  
Power source 2 is available  
Power source 2 is not available  
Power failure or port failure  
Normal Operation  
Power 1  
Power 2  
Fault  
Green  
Off  
Yellow  
Off  
Green  
The port is linked  
LNK/ACT (port 5)  
Blinking  
Off  
The port is transmitting or receiving  
No device attached  
RJ-45 or Fiber Optic  
The port is operating in full-duplex  
mode  
Yellow  
Blinking  
Off  
FDX/COL (port 5)  
Data Packet Collision  
RJ-45 or Fiber Optic  
The port in half-duplex mode or is  
not connected to a device  
Ports  
RJ-45 ports  
There are 5x 10/100Mbps auto-sensing ports for 10Base-T or 100Base-TX  
device connection. The ports are auto-sensing and auto MDI/MDIX.  
6
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RJ-45 Pin Assignments  
Pin Number  
Assignment  
1
2
3
6
Tx+  
Tx-  
Rx+  
Rx-  
All ports on this switch support automatic MDI/MDI-X operation.  
Straight-through cables can be used for all network connections. In  
straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are  
connected straight through to pins 1, 2, 3 and 6 at the other end of the cable.  
The table below shows the 10BASE-T/100BASE-TX MDI and MDI-X port  
pin outs.  
Pin MDI-X  
Signal Name  
MDI Signal Name  
1
2
3
6
Receive Data plus (RD+)  
Transmit Data plus (TD+)  
Receive Data minus (RD-) Transmit Data minus (TD-)  
Transmit Data plus (TD+) Receive Data plus (RD+)  
Transmit Data minus (TD-) Receive Data minus (RD-)  
Straight Through Cable Schematic  
Manual Documentation Number: EIR505-xx_5107m  
7
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cross Over Cable Schematic  
Fiber Port  
There is one 100Base-FX port. The fiber port is SC type connector in multi  
mode (2Km) or single mode (30Km).  
Connect the fiber port as described below.  
ATTENTION  
This is a Class 1 Laser/LED product. Do not stare into  
the Laser/LED Beam.  
Cabling  
Use Category 5 cabling for RJ-45 port connections. The cable must  
be less than 328 ft (100 meters) long.  
Use 8/125 or 9/125 um for single-mode fiber. Distances up to 30  
8
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Kilometers are supported.  
Fuse 50 or 62.5/125 um for multi-mode fiber cable. Distances up to  
2Kmare supported.  
Wiring the Power Inputs  
V- V+  
V- V+  
1. Insert the positive and negative wires into the V+ and V-  
connector on the terminal block connector  
2. Tighten the wire-clamp screws  
[NOTE] Use 12~ 24 AWG wire.  
Manual Documentation Number: EIR505-xx_5107m  
9
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring the Fault Alarm Contact  
The fault alarm contact are located in the middle of terminal block connector  
as shown below. Insert the wires and set the Dipswitch to “ON”. When a  
power source fails or a link fault occurs, it will be detected and cause an  
open circuit. The following figure shows an application example for the fault  
alarm contact.  
1A@24V  
Insert the wires into the fault alarm contact  
[NOTE] The wire range of terminal block is from 12~ +24 AWG.  
Fault Alarm Contact  
The open circuit will form when the  
power failure or port link failure.  
24V DC Buzzer  
24V Battery  
The fault alarm device will send a  
warning signal to warn the user, ex:  
alarm sound or flash light.  
10  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting Installation  
DIN-Rail Mounting  
Rear Panel of  
the switch  
DIN-Rail  
Use the screws to attach the DIN-Rail to the industrial  
switch  
To remove the DIN-Rail, reverse the step 1.  
Manual Documentation Number: EIR505-xx_5107m  
11  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. First, insert the top of DIN-Rail into the track.  
2. Then, lightly push the DIN-Rail into the track.  
3. Ensure the DIN-Rail is tightly secured to the track.  
4. To remove the industrial switch from the track, reverse steps above.  
12  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Panel Mounting  
Follow the steps below to mount the industrial switch with the Panel mount  
plate.  
1. Remove the DIN-Rail from the industrial switch.  
2. Place the wall Panel plate on the rear of the industrial switch.  
3. Use the screws to attach the Panel plate to the industrial switch  
4. Use the hook holes at the corners of the panel mount plate to attach the  
industrial switch to the panel.  
5. To remove the panel mount plate, reverse steps above  
Manual Documentation Number: EIR505-xx_5107m  
13  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Installation  
.
1. Unpack the Industrial switch.  
2. Ensure the DIN-Rail is tightly screwed to the Industrial switch. If not,  
refer to DIN-Rail Mounting section for DIN-Rail installation. To panel  
mount the Industrial switch, refer to Panel Mounting section.  
3. Apply power to the switch (refer to the Wiring the Power Inputs  
section). The power LED will light.  
4. Connect CAT 5 cables to the Industrial switch’s RJ-45 ports and to the  
network devices.  
[NOTE] If the network devices do not support MID/MDIX, a  
crossover cable may be required.  
5. Connect the fiber optic cables to the industrial switch and network device.  
Ensure that the switch’s fiber optic transmitter is connected to the  
network devices receiver and vice versa.  
6. When all the connections are made and the LEDs show normal  
indications, the installation is complete.  
14  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network Application  
X-Ring Application  
The EIR505 series of Industrial Switches incorporate the X-Ring Protocol to  
ensure network reliability and system restoration within 300 ms in the event  
of a connection failure. The X-Ring algorithm is similar to the spanning tree  
protocol (STP) algorithm but it has faster recovery time. The following figure  
below is an example of an X-Ring application.  
Manual Documentation Number: EIR505-xx_5107m  
15  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Coupling Ring Application  
If the network has more than one X-Ring group, the coupling ring function is  
used to connect them and add redundancy. This ensures that transmissions  
between the two ring groups will not fail. The figure below is an example of  
the coupling ring application.  
16  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dual Homing Application  
The Dual Homing function is used to prevent a connection loss between the  
X-Ring group and the upper level/core switch. Assign a port in each X-ring  
group to be the Dual Homing ports The Dual Homing function can only be  
used when the X-Ring function is active. Each X-Ring group can have one  
Dual Homing port.  
[NOTE] In the Dual Homing architecture, the upper level switches must  
have Rapid Spanning Tree protocol enabled.  
Manual Documentation Number: EIR505-xx_5107m  
17  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Web-Based Management  
About Web-based Management  
The switch has an embedded HTML web site residing in flash memory. This  
site offers advanced management features and allows the switch to be  
configured from anywhere on the network.  
The web site is designed for Internet Explorer 5.0 and uses Java Applets to  
reduce bandwidth consumption, enhance access speed, and present an  
intuitive user interface.  
[NOTE] By default, IE5.0 and later versions do not allow Java Applets to  
activate sockets. The user must modify the browser setting to enable Java  
Applets to operate network ports.  
Preparing for Web Management  
Before using web management, install the industrial switch on the network  
and verify that a PC on the local network can connect with the switch  
through the web browser. The default IP Address, Subnet Mask, Username  
and Password is listed below:  
IP Address: 192.168.16.1  
Subnet Mask: 255.255.255.0  
Default Gateway: 192.168.16.254  
User Name: root  
Password: root  
18  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Login  
1. Launch Internet Explorer on the PC.  
and then Press “Enter”.  
3. The login screen will appear.  
4. Enter the user name and password.  
5. Press Enter” or “OK”, the home screen will appear.  
Function Menu Bar  
Home Interface  
Panel Figure Display  
Configuration Display Screen  
Manual Documentation Number: EIR505-xx_5107m  
19  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port status  
Shows the status of each port  
Port: Displays the port number  
Type: Displays the speed and mode, ex: 100TX = 100Mbps  
Link: Displays the ports status (up or down)  
State: Displays the ports status (disabled or enabled). Unlinked is  
displayed as “off ”  
Negotiation: Displays the auto negotiation mode (auto or forced).  
Speed Duplex: Displays the port connection speed. “Config” is the  
configured value. “Actual” is the current value.  
Flow Control: Displays the flow control status as “Symmetric” or  
“Asymmetric” in full mode. “Disable” means that flow control is not  
enabled “Config” indicates that the value is user configured. “Actual” is  
the current value of the port.  
Port Status interface  
Single Port Information  
Click the desired port on the Panel figure. The single port information  
window will display the current port information.  
20  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port information interface  
Port Statistics  
Clear  
Displays port statistics. Click  
button to reset.  
Port Statistics Interface  
Manual Documentation Number: EIR505-xx_5107m  
21  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Control  
Used to set up the port.  
1. Select the port by scrolling down the Port column. The current port  
information will be displayed in the table below.  
2. State: Enables or disables the port.  
3. Negotiation: Sets the negotiation mode to Auto, Nway (specify the  
speed/duplex of the port and enable auto-negotiation), or Forced.  
4. Speed: Sets the transmit speed of the port  
5. Duplex: Sets the port to full-duplex or half-duplex  
6. Flow control: Sets flow control function to Symmetric or Asymmetric  
in Full Duplex mode(The default value is Disable)  
Apply  
7. Click the  
button to apply configurations  
8. Select the port again to verity the configuration.  
[NOTE] If the configuration is not saved it will be lost when the switch  
is powered off.  
Port Control interface  
22  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Switch Settings  
Used to assign the system name, location and to view system information  
System Name: Assigns a name to the switch. The maximum length is  
64 bytes  
System Location: Assigns a physical location for the switch. The  
maximum length is 64 bytes  
System Description: Displays the description of switch. This is read  
only and cannot be modified  
Firmware Version: Displays the firmware version  
Kernel Version: Displays the kernel software version  
Hardware version: Display the hardware version  
MAC Address: Display the unique hardware address assigned by  
manufacturer (this value is different for each switch)  
Switch settings interface  
[NOTE] If the configuration is not saved, it will be lost when the switch  
is powered off.  
[NOTE] The Firmware, Hardware, and Kernel versions listed above are  
current as of the date this manual was produced.  
Manual Documentation Number: EIR505-xx_5107m  
23  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Mirroring  
Port mirroring is a method to monitor traffic in switched networks. This is  
accomplished by mirroring the traffic going in and out of the monitored ports  
to a specifically designated port (the mirror port).  
1. Port Mirroring Mode: Sets the mirror mode. Select disable to disable  
port mirroring. Select TX to monitor data being transmitted by a port.  
Select both to monitor port data being transmitted and received by a  
port. The default value is “Disable”.  
2. Analysis Port: This is the port used to see all monitored port traffic  
(This port can be connected to a LAN analyzer or Netxray).  
3. Monitor Port: Check the box to monitor the port. Up to 4 ports can be  
designated as monitor ports.  
[NOTE]  
If the configuration is not saved, it will be lost when the port is  
powered off.  
Port Mirroring interface  
24  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN configuration  
A Virtual LAN (VLAN) can be thought of as a broadcast domain that exists  
within a switch or a defined set of switches. By grouping switch ports into  
VLANs, traffic flooding is limited since devices can only communicate  
directly with devices belonging to the VLAN. Creating a VLAN from a switch  
is the logical equivalent of reconnecting a group of devices to another Layer  
2 switch. However, the network devices retain their same physical  
connection. The EIR505 series switches support port-based and 802.1Q  
(tagged-based) VLAN. In the default configuration, the VLAN option is  
disabled.  
VLAN Configuration interface  
Port-based VLAN  
With port-based VLAN, the port is assigned to a VLAN. Therefore all  
devices attached to a given port should be members of the same VLAN. As  
with other VLAN configurations, the packets forwarded using this method do  
not leak into other VLAN domains on the network. After the port has been  
assigned to a VLAN, devices on the port cannot send to or receive from  
devices in other VLANs without the intervention of another layer 3 device or  
the ability to tag the data packet with a specific PVID.  
Manual Documentation Number: EIR505-xx_5107m  
25  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN – Port Base interface  
Add  
1. Click  
to add a new VLAN group. The EIR505 series supports up  
to 64 VLAN groups  
2. Enter Group name, VLAN ID and select the members of VLAN group  
Apply  
3. Click  
26  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN—Port Base Add interface  
4. The VLAN group will be displayed after apply is clicked  
Next Page  
5. Click  
6. Use  
7. Use  
to view the next VLAN group  
button to delete unwanted VLANs  
button to modify existing VLANs  
Delete  
Edit  
[NOTE] If the configuration is not saved, it will be lost when the switch  
is powered off  
802.1Q VLAN  
Tagged-based VLAN is an IEEE 802.1Q specification which allows VLANs  
to be created across devices from different venders. IEEE 802.1Q VLAN  
Manual Documentation Number: EIR505-xx_5107m  
27  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
uses a technique to insert a “tag” into the Ethernet frame. The tag contains a  
VLAN Identifier (VID).  
When the 802.1Q VLAN is enabled, all ports on the switch belong to a  
default VLAN (VID 1). The default VLAN can’t be deled. The EIR505 series  
will support up to 64 VLAN groups.  
802.1q VLAN interface  
Basic  
Add  
1. Click  
2. Management VLAN ID:  
Used for Remote Management Security.  
When this option is selected, remote management is only available to  
the members of the indicated VLAN Group. Enter the specific VLAN ID  
number in Management VLAN ID column, check the box, and click the  
Apply  
button. Example: If the management VLAN ID is 101 and the  
VLAN group ID 101 includes ports 1, 2, and 4, only ports 1, 2, and 4  
can perform remote management functions on the switch. If a port is in  
multiple VLAN groups, it can still perform management functions as  
long as one VLAN group ID is equal to the Management VLAN ID.  
28  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Group Name: assign a name for the new VLAN  
4. VLAN ID: fill in a VLAN ID. The default is 1  
5. From the Available ports box, select ports to add to the VLAN group  
Add  
and click  
button  
802.1q VLAN –Add interface  
Next  
6. Click  
to bring up the configuration interface:  
Manual Documentation Number: EIR505-xx_5107m  
29  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Select outgoing frames as VLAN-Tagged frames or untagged and then  
Apply  
click  
Configure port VID settings  
Port VID:  
1. Port VLAN ID: enter the port VLAN ID  
Apply  
2. And then, click  
Default  
3. To reset to the default values, click  
button  
30  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
802.1q VLAN – Port VLAN ID interface  
[NOTE] If the configuration is not saved, it will be lost if the switch is  
powered off.  
IP Address  
Configure the IP Settings and DHCP client function  
DHCP Client: Use to enable or disable the DHCP client function. When  
the DHCP client function is enabled, the industrial switch will be  
assigned an IP address from the network DHCP server. After the  
“Apply” button is clicked, dialog box will indicate that the user that when  
the DHCP client is enabled, the current IP will lost and the new IP must  
be looked up on the DHCP server. The switch’s MAC Address will be  
required to look up the new IP Address on the DHCP Server. To cancel  
the DHCP client function, click “cancel”.  
IP Address: Assign a static IP address. This is not required if DHCP  
Manual Documentation Number: EIR505-xx_5107m  
31  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Client is enabled. The default IP is 192.168.10.1.  
Subnet Mask: Assign the subnet mask of the IP address. This is not  
required if the DHCP Client is enabled.  
Gateway: Assign the network gateway. The default gateway is  
192.168.10.254.  
Apply  
Click  
IP configuration interface  
SNTP Configuration  
SNTP (Simple Network Time Protocol) allows the switch to synchronize its  
time with an SNTP Server.  
1. SNTP Client: Enable or Disable SNTP  
2. Daylight Saving Time: Enables or disables daylight saving time. When  
enabled, the daylight saving time period must be entered.  
3. UTC Time zone: Used to calculate local time. Set the switch location  
time zone.  
Local Time Zone  
Conversion from UTC  
Time at 12:00 UTC  
November Time  
Zone  
- 1 hour  
-2 hours  
11am  
Oscar Time Zone  
10 am  
32  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADT - Atlantic  
Daylight  
-3 hours  
-4 hours  
9 am  
8 am  
AST - Atlantic  
Standard  
EDT - Eastern  
Daylight  
EST - Eastern  
Standard  
-5 hours  
-6 hours  
-7 hours  
7 am  
6 am  
5 am  
CDT - Central  
Daylight  
CST - Central  
Standard  
MDT - Mountain  
Daylight  
MST - Mountain  
Standard  
PDT - Pacific  
Daylight  
PST - Pacific  
Standard  
-8 hours  
-9 hours  
4 am  
3 am  
ADT - Alaskan  
Daylight  
ALA - Alaskan  
Standard  
HAW - Hawaiian  
Standard  
-10 hours  
-11 hours  
2 am  
1 am  
Nome, Alaska  
CET - Central  
European  
FWT - French Winter  
MET - Middle  
European  
+1 hour  
1 pm  
MEWT - Middle  
Manual Documentation Number: EIR505-xx_5107m  
33  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
European Winter  
SWT - Swedish  
Winter  
EET - Eastern  
European, Russia  
Zone 1  
+2 hours  
+3 hours  
2 pm  
3 pm  
BT - Baghdad,  
USSR Zone 2  
ZP4 - Russia Zone 3  
ZP5 - Russia Zone 4  
ZP6 - Russia Zone 5  
WAST - West  
Australian Standard  
CCT - China Coast,  
USSR Zone 7  
JST - Japan  
+4 hours  
+5 hours  
+6 hours  
4 pm  
5 pm  
6 pm  
+7 hours  
+8 hours  
7 pm  
8 pm  
Standard, Russia  
Zone 8  
+9 hours  
9 pm  
EAST - East  
Australian Standard  
GST  
+10 hours  
10 pm  
Guam Standard,  
Russia Zone 9  
IDLE - International  
Date Line  
NZST - New  
+12 hours  
Midnight  
Zealand Standard  
NZT - New Zealand  
4. SNTP Sever IP: Enter the IP address of the SNTP server.  
5. Switch Timer: Displays the switch’s current time  
6. Daylight Saving Period: Enter the daylight saving time period  
7. Daylight Saving Offset (mins): Configuring the offset value in minutes  
Apply  
8. Click  
to active the configuration  
34  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[NOTE] If the configuration is not saved, it will be lost when the switch  
is powered off.  
SNTP Configuration  
IP Security  
IP security function grants 10 specific IP addresses permission to access  
the switch through a web browser for the switch management.  
1. Enable the IP Security: Mark the check box to enable  
2. Security IP 1 ~ 10: Enter up to 10 specific IP address.  
Apply  
3. Click  
[NOTE] If the configuration is not saved, it will be lost when the switch  
is powered off.  
Manual Documentation Number: EIR505-xx_5107m  
35  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IP Security Interface  
RSTP Configuration  
The Rapid Spanning Tree Protocol (RSTP) is an evolution of Spanning Tree  
Protocol (STP). It provides a faster spanning tree convergence after a  
topology change. The switch will auto detect a device that is running STP or  
RSTP protocol.  
System Configuration  
Modify RSTP state parameters  
RSTP mode: Enable or disable RSTP function.  
Priority (0-61440): a value used to identify the root bridge. The bridge  
with the lowest value has the highest priority and is selected as the root.  
If the value changes, the switch must be rebooted. The priority value  
must be multiple of 4096 according to the protocol standard rule.  
Max Age (6-40): the number of seconds a bridge waits without  
receiving Spanning-tree Protocol configuration messages before  
attempting a reconfiguration. Enter a value between 6 and 40.  
Manual Documentation Number: EIR505-xx_5107m  
36  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hello Time (1-10): The time that the control switch sends out a BPDU  
packet to check RSTP status. Enter a value between 1 and 10.  
Forward Delay Time (4-30): The number of seconds a port waits  
before changing from its Rapid Spanning-Tree Protocol learning and  
listening states to the forwarding state. Enter a value between 4  
through 30.  
Apply  
Click  
[NOTE]  
1. Use the following rule to configure the MAX Age, Hello Time,  
and Forward Delay Time.  
2 x (Forward Delay Time value –1) > = Max Age value >= 2  
x (Hello Time value +1)  
If the configuration is not saved it will be lost when the switch  
is powered off.  
RSTP– System Configuration Interface  
Manual Documentation Number: EIR505-xx_5107m  
37  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Per Port Configuration  
Configure path cost and priority of every port  
1. Select the port in Port column  
2. Path Cost: The cost of the path to the other bridge from this transmitting  
bridge at the specified port. Enter a number 1 through 200000000  
3. Priority: Network Priority. Enter a number from 0 to 240. The value must  
be a multiple of 16  
4. Admin P2P: Some of the rapid state transactions that are possible  
within RSTP are dependent upon whether the port concerned can only  
be connected to one other bridge (i.e. it is served by a point-to-point LAN  
segment), or whether it can be connected to two or more bridges (i.e. it  
is served by a shared medium LAN segment). This function allows the  
P2P status of the link to be manipulated administratively. True is P2P  
enabling. False is P2P disabling  
5. Admin Edge: The port directly connected to end stations cannot create  
a bridging loop. To configure the port as an edge port, set the port to  
True” status  
6. Admin Non Stp: The port includes the STP mathematic calculation.  
True does not include the STP mathematic calculation. False includes  
the STP mathematic calculation  
Apply  
7. Click  
[NOTE] If the configuration is not saved, it will be lost when the switch  
is powered off.  
38  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RSTP – Per Port Configuration interface  
X-Ring  
X-Ring provides network redundancy similar to the Spanning Tree and  
Rapid Spanning Tree Protocols. However, recovery time is greatly reduced  
when the X-Ring protocol is used. The protocol identifies one switch as the  
Ring Master. Packets are blocked from the redundant path unless a ring  
member becomes disconnected from the rest of the network. When this  
happens, the protocol automatically restores connectivity using the  
redundant path.  
In the X-Ring topology, every switch should enable X-Ring function and  
assign two member ports to the ring. Only one switch in the X-Ring group  
would be set as the backup switch. Other switches are called working  
switches and their two member ports are called working ports. If a network  
connection failure occurs, the backup port will automatically become a  
working port to recover.  
The switch has a Dipswitch to configure the switch as the ring master. The  
Manual Documentation Number: EIR505-xx_5107m  
39  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ring master has the rights to negotiate and place a command to other  
switches in the X-Ring group. If more than one switch is in master mode,  
the software will select the switch with lowest MAC address number as the  
ring master. An LED on the front panel indicates that the switch is the ring  
master.  
Coupling ring is used to connect 2 or more X-Ring groups providing a  
redundant back-up Dual homing is used to recover from a connection loss  
between an X-Ring group and the upper level/core switch.  
Enable X-Ring: Mark the check box to enable the X-Ring function  
1st & 2nd Working Ports: Assign two ports as the member ports. One  
port will be working port and one port will be the backup port. The  
system will automatically decide which port is working port and which  
port is backup port  
Enable Coupling Ring: Mark the check box to enable the coupling  
ring function  
Coupling port: Assign the member port  
X-Ring Master: Set the switch labeled RM on front panel to on position.  
This establishes that switch as a master for the ring.  
Enable Dual Homing: Set up one of port to be the Dual Homing port.  
In an X-Ring group, only one can be a Dual Homing port. This function  
will only work when the X-Ring function is enabled  
Apply  
Click  
40  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X-Ring Interface  
[NOTE]  
1. When the X-Ring function is enabled, the RSTP function must be  
disabled.  
2. If the configuration is not saved, it will be lost when the switch is  
powered off.  
QoS Configuration  
Qos Policy: select the Qos policy rule  
¾
Using the 8,4,2,1 weight fair queue scheme: The switch will  
follow 8:4:2:1 rate to process priority queue from Highest to lowest.  
For example: the system will process 8 high queue packets, 4  
middle queue packets, 2 low queue packets, and one lowest  
queue packets at the same time  
¾
Use the strict priority scheme: The highest queue will always be  
processed first.  
Priority Type: Every port has 5 priority types  
¾
Port-base: The port priority will follow the default port priority  
assigned – High, middle, low, or lowest  
Manual Documentation Number: EIR505-xx_5107m  
41  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
¾
¾
¾
COS only: The port will follow the COS priority assigned  
TOS only: The port will follow the TOS priority assigned  
COS first: The port will follow COS priority first, and then another  
priority rule  
¾
TOS first: The port will follow TOS priority first, and then another  
priority rule  
COS priority: Set the COS priority level 0~7  
TOS priority: The system provides 0 to 63 TOS priority levels. Each  
level has 4 types of priority – high, mid, low, and lowest. The default  
value is “Lowest”. When the IP packet is received, the system will check  
the TOS value.  
[NOTE] QoS and Rate control cannot be used simultaneously.  
42  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QoS configuration Interface  
IGMP  
The Internet Group Management Protocol (IGMP) is an internal protocol of  
the Internet Protocol (IP) suite. IP manages multicast traffic by using  
switches, routers, and hosts that support IGMP. Enabling IGMP allows the  
ports to detect IGMP queries and report packets and manage IP multicast  
traffic through the switch. IGMP has three fundamental types of messages:  
Manual Documentation Number: EIR505-xx_5107m  
43  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Message  
Query  
Description  
A message sent from an IGMP router or switch  
requesting a response from each host belonging to  
the multicast group.  
A message sent by a host indicating that the host  
wants to be or is a member of a given group.  
Report  
A message sent by a host indicating that the host  
has is no longer a member of a specific multicast  
group.  
Leave Group  
[NOTE] If the configuration is not saved, it will be lost when the switch  
is powered off.  
IGMP Snooping interface  
44  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security Manager  
Use to change the web management login user name and password.  
1. User name: enter the new user name(The default is “root”)  
2. Password: enter the new password(The default is “root”)  
3. Confirm password: reenter the new password  
Apply  
4. Click  
[NOTE] If the configuration is not saved, it will be lost when the switch  
is powered off.  
Security Manager Interface  
Configuration Backup  
Used to backup the configuration to a TFTP server and load the backup  
configuration from the TFTP server.  
TFTP Restore Configuration  
Restore flash ROM value from the TFTP server.  
1. TFTP Server IP Address: Enter the TFTP server IP  
2. Restore File Name: Enter the file name  
Apply  
3. Click  
Manual Documentation Number: EIR505-xx_5107m  
45  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TFTP Restore Configuration interface  
TFTP Backup Configuration  
Save current flash ROM value to the TFTP server  
1. TFTP Server IP Address: Enter the TFTP server IP  
2. Backup File Name: Enter the file name  
Apply  
3. Click  
TFTP Backup Configuration interface  
TFTP Update Firmware  
Use to update firmware. Ensure the TFTP server is ready and the firmware  
image is stored on the TFTP server,  
1. TFTP Server IP Address: Enter the TFTP server IP Address  
2. Firmware File Name: Enter the name of firmware image  
Apply  
3. Click  
46  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TFTP Update Firmware interface  
Factory Default  
Reset the Switch to the default configuration. NOTE: The IP Address,  
subnet mask, default gateway, username, and password will remain as  
configured by the user.  
Default  
Click  
Factory Default interface  
System Reboot  
Reboot the switch in software reset  
Reboot  
Click  
System Reboot interface  
Manual Documentation Number: EIR505-xx_5107m  
47  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Save Configuration  
Save the configuration to flash memory. If the switch is powered off without  
saving the configuration, all changed configuration will lost  
Save Flash  
Click  
Save Configuration Interface  
Rate Control  
Set up each port’s bandwidth rate and packet limitation type  
Limit Packet type: Select the packet type to filter. The packet filter  
types are all packet types, broadcast/multicast/unknown, unicast  
packets, broadcast/multicast packets, and broadcast packet only. The  
broadcast/multicast/unknown, unicast packet, broadcast/multicast  
packet, and broadcast packet only are only for ingress. The egress rate  
only supports all packet types.  
Ports 1 through 5 support port ingress and egress rate control. For  
example, assume port 1 is 10Mbps, users can set its effective egress  
rate to 1Mbps, and the ingress rate to 500Kbps.  
¾
Ingress: Select the port effective ingress rate. The valid range  
value is 1MB, 2MB, 4MB, 8MB, 16MB, 32MB and 64MB. The  
default value is “disable”  
¾
Egress: Select the port effective ingress rate. The valid range  
value is 128kbps, 256Kbps, 512Kbps, 1MB, 2MB, 4MB, and 8MB.  
The default value is “disable”  
Apply  
Click  
48  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[NOTE]  
1. If the configuration is not saved, it will be lost when the switch is  
powered off.  
2. Qos and Rate control cannot exist at the same.  
Rate Control Interface  
Manual Documentation Number: EIR505-xx_5107m  
49  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble shooting  
Verify the power supply is correct (12-48V DC) Do not exceed 48V DC.  
Ensure the proper UTP cable is used for RJ-45 connections: 100Ω  
Category 3, 4 or 5 cable for 10Mbps connections or 100Ω Category 5  
cable for 100Mbps connections. Ensure that the length of any  
twisted-pair connection does not exceed 328 feet (100 meters).  
LED Indicators: Assist in identifying problems.  
50  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specification  
IEEE 802.3 10Base-T Ethernet  
IEEE 802.3u 100Base-TX Fast Ethernet  
IEEE802.3x Flow Control and Back-pressure  
IEEE802.1d spanning tree / IEEE802.1w rapid  
spanning tree  
Standards  
IEEE802.1p class of service  
IEEE802.1Q VLAN Tag  
Protocol  
CSMA/CD  
Provides Web interface management and one  
default button for system default setting  
Management  
Technology  
Store and forward switching architecture  
14,880 pps for Ethernet port  
Transfer Rate  
148,800 pps for Fast Ethernet port  
Transfer packet  
size  
64bytes to 1522 bytes (with VLAN tag)  
2K MAC address table  
MAC address  
Memory Buffer  
Back-plane  
1Mbits  
1.0 Gbps  
Packet throughput  
ability  
1.49Mpps @64bytes (4TX +1 FX)  
Manual Documentation Number: EIR505-xx_5107m  
51  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Per port: Link/Activity (Green), Full  
duplex/Collision (Yellow)  
Per unit: Power (Green), Power 1 (Green),  
LED  
Power 2 (Green), Fault (Yellow), Master (Green)  
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable  
EIA/TIA-568 100-ohm (100m)  
Network Cable  
100Base-TX: 2-pair UTP/STP Cat. 5 cable  
EIA/TIA-568 100-ohm (100m)  
SC (Multi-mode): 50/125um~62.5/125um  
SC (Single mode): 9/125um~10/125um  
Available distance: 2KM (Multi-mode) / 30KM  
(single-mode)  
Optical cable  
Wavelength: 1310nm (multi-mode/ single mode)  
Redundant 12 to 48 V DC power inputs with  
reverse polarity protection  
Power Supply  
Power  
3.64 Watts  
consumption  
4 selection rules :  
All packets  
Broadcast/ multicast/ unknown unicast  
packets  
Packet filter  
Broadcast/ multicast packets  
Broadcast packets only  
IEEE802.1p class of service support, 4 priority  
queues per port.  
Class of service  
52  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
port based  
Quality of service  
Tag based  
IPv4 Type of service  
X-Ring  
300 ms Recovery Time  
Port based VLAN and IEEE802.1Q Tag VLAN.  
Both port based and Tag based VLAN groups  
(up to 64).  
VLAN  
IEEE802.1d spanning tree and IEEE802.1w  
rapid spanning tree.  
Spanning tree  
IGMP  
SNTP  
IGMP v1 and Query mode. Up to 256 groups.  
Simple Network time protocol  
Management IP  
security  
IP address security to prevent intrusion  
Port mirror  
TX packet only or both TX and RX packet.  
Manual Documentation Number: EIR505-xx_5107m  
53  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install  
Alarm  
DIN rail and panel mount  
One 24VDC, 1A relay output.  
TFTP firmware update  
Firmware update  
DHCP client  
TFTP configuration backup and restore.  
DHCP client function to obtain the IP address  
from a DHCP server.  
Ingress packets filter and egress packet limit  
The egress rate control supports all of  
packet type and the limit rates are 128kbps,  
256Kbps, 512Kbps, 1MB, 2MB, 4MB, and  
8MB  
Ingress filter packet type combination rules  
are Broadcast/Multicast/Unknown Unicast  
packet, Broadcast/Multicast packet,  
Broadcast packet only and all of packet. The  
packet filter rate can be set follow  
Bandwidth control  
as:1Mbps2Mbps4Mbps8Mbps、  
16Mbps32Mbps64Mbps  
0to 60(32to 140)  
5% to 95% (Non-condensing)  
-40to 85℃  
Operation Temp.  
Operation  
Humidity  
Storage  
Temperature  
IP-30, 2.12 (W) x 4.31 (H) x ,4.13 (D) in (5.4 x  
13.5 x 10.5 cm)  
Case Dimension  
54  
Manual Documentation Number: EIR505-xx_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC Class A, CE EN6100-4-2, CE  
EN6100-4-3, CE EN-6100-4-4,  
CE EN6100-4-5, CE EN6100-4-6  
EMI  
Safety  
EN60950  
IEC60068-2-32 (Free fall), IEC60068-2-27  
(Shock), IEC60068-2-6 (Vibration)  
Stability testing  
Manual Documentation Number: EIR505-xx_5107m  
55  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Abocom Network Router UCM560 User Manual
Access Personal Computer AIM 16 User Manual
Acer Computer Monitor 718 User Manual
Acer Personal Computer G520 series User Manual
AEG Ventilation Hood 8609 D User Manual
Altinex Stereo Amplifier DA1226AT User Manual
American Dryer Corp Clothes Dryer AD 385 User Manual
Axis Communications Security Camera F44 User Manual
Bahco Lopper P14 User Manual
BC Speakers Portable Speaker 8 PL 21 User Manual