Ayre V-5xe
Owner’s Manual
Power Amplifier
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of
Contents
Welcome to
Ayre . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . 3
Operation. . . . . . . . . . . . . . . . . . . . . 6
Specifications . . . . . . . . . . . . . . . . . . . 9
Trouble . . . . . . . . . . . . . . . . . . . . . 10
Warranty . . . . . . . . . . . . . . . . . . . . 13
Notes . . . . . . . . . . . . . . . . . . . . . . 16
Connections and
Controls and
Numbers and
In Case of
Statement of
A Place for
Download from Www.Somanuals.com. All Manuals Search And Download.
Welcome to
Ayre
Your Ayre V-5xe offers a significant advance in the
musical performance of high-fidelity equipment.
The warmth and immediacy of a live performance
are apparent from the first listening. The
combination of superb resolution and a natural,
relaxed quality will draw you into the music, time
and time again.
This level of performance has been implemented
using the highest level of workmanship and
materials. You can be assured that the Ayre V-5xe
will provide you a lifetime of musical enjoyment.
To our North American customers, please be
sure to mail your warranty registration card and
photocopy of your original sales receipt within 30
days in order to extend the warranty to five
years.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Connections and
Installation
The Ayre V-5xe is easy to connect and use. The
following guidelines will ensure that the installation
goes smoothly.
Location
Do not stack the Ayre V-5xe
directly with other components,
as this may restrict the air
flow or induce hum into the
audio circuitry.
A good location for your power amplifier is on the
floor between your loudspeakers, or in an
open-backed cabinet, or on a shelf. The Ayre V-5xe
produces a moderate amount of heat during
operation. Be sure to provide at least three inches
(75 mm) of air space above the amplifier.
It is important to maintain an adequate
supply of air flow to avoid overheating
the amplifier.
Inputs
The Ayre V-5xe can be driven either by a
preamplifier or directly from a line-level source
(e.g., a tuner or CD player) that has a level control.
There are two sets of input connectors on the rear
3
Download from Www.Somanuals.com. All Manuals Search And Download.
panel of the Ayre V-5xe. The RCA connectors
accept signals from unbalanced sources, while the
XLR connectors are for balanced sources. A small
toggle switch near the input connectors selects
either the balanced or unbalanced inputs.
When you have a choice, a balanced connection
will offer slightly higher sound quality than an
unbalanced connection.
Note that the input selector switch for one channel
will be in the “up” position, while the other
channel’s input selector switch will be in the
“down” position.
Only one set of inputs (balanced or
unbalanced) may be connected at a
time.
Pass-Through Outputs
The pass-through output
connector is wired in parallel
with the input connector.
Each channel features a pass-through output,
supplied via an XLR connector. This allows
multiple channels to be driven with a single source
and is especially useful for subwoofers, passive bi- or
tri-amplification, or distributed sound systems.
Simply use a balanced cable to connect the
pass-through output of one channel to the XLR
input of another channel on the same amplifier, or of
another amplifier with true balanced inputs.
The pass-through output does
not convert unbalanced sources
to a true balanced signal.
If you wish to drive an unbalanced amplifier from
the pass-through outputs, you will need to use
XLR-to-RCA adapters at the pass-through outputs.
These are available from your Ayre dealer.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
¡Attention! — Balanced Outputs
Do Not Connect Output Terminals to Ground
V-5 Power Amplifier S.N.
Unbal
Input Sel
Pass-Through
Output
Trigger In/Out
Bal
Fuse
-
+
Fuse
Volts
50/60 Hertz
700
W
Max
Fuse
+
-
Fuse
Pass-Through
Output
Bal
Input Sel
Unbal
Boulder, Colorado USA
A y r e
Loudspeaker Outputs
The heavy-duty output
terminals of the Ayre V-5xe
work best with speaker cables
using spade lugs.
The Ayre V-5xe drives the loudspeakers with
balanced outputs. Since none of the output
terminals are grounded, connecting any of them to
ground may result in damage to the amplifier.
Do not connect the loudspeaker
outputs to any speaker switch-box,
accessory, or test equipment that has a
common ground connection.
AC Power
The V-5xe may be plugged directly into an
unswitched wall outlet. Although proprietary RFI
(radio-frequency interference) filtering is built into
the amplifier, in some situations an AC power-line
filter (such as those offered by Ayre) may provide
additional sonic benefits.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Controls and
Operation
The Ayre V-5xe has a front panel control for normal
stand-alone operation. The amplifier may also be
controlled via a “trigger” input in a home-theater.
Power Switches
The master power switch on
the rear panel also
incorporates a circuit breaker
that acts as a resettable fuse.
There are two power switches on the Ayre V-5xe.
The master power switch on the rear panel is
normally intended to be left on at all times. The
front-panel switch selects between the “Standby”
and “Operate” modes.
When the master power switch is first turned on,
the front panel indicator light will glow red for
approximately one second. During this time, the
unit is in “Warm-Up” mode and the front-panel
switch is inoperable.
Red = Warm-Up
Green = Standby
Blue = Operate
After the circuitry has stabilized, the indicator light
will change to green, indicating that the unit is in
“Standby” mode and is ready for operation. When
the listener presses the front-panel switch, the unit
is in “Operate” mode and the indicator light glows
blue.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
In the green “Standby” mode the output stage is
turned off, while the input circuitry remains
powered. This allows the unit to warm up quickly
for optimal sonic performance, while reducing the
power consumption from 120 watts to 20 watts.
Trigger Input
Use a 1/8" mini-phone plug
with a positive voltage of
between +5 and +12 VDC
at the tip to operate the trigger
input.
A trigger input is provided on the rear panel of the
V-5xe to allow for remote switching between the
green “Standby” and blue “Operate” modes. The
two trigger input jacks are wired in parallel. Either
jack can act as an input or a pass-through output to
allow for “daisy-chaining” of multiple devices.
The unit is shipped from the factory in the
level-sensitive mode, which is compatible with most
equipment. During level-sensitive operation,
applying a voltage to the trigger input will turn the
amplifier to the “Operate” mode. When the applied
voltage drops to zero, the unit reverts to “Standby.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Some equipment instead utilizes pulses as a trigger
signal. The V-5xe can also accommodate these units.
To change trigger modes, turn the rear panel switch
“Off” for about 30 seconds to discharge the internal
voltages. Then press and hold the front panel switch
while turning the rear panel switch “On”. The status
LED will rapidly flash red (about 10 Hz) to indicate
that the pulse-sensitive mode has been selected.
Repeating this procedure will revert the unit back
to the level-sensitive mode, as indicated by the
status LED slowly flashing red (about 1 Hz).
In the pulse-sensitive mode, a positive-going pulse
edge will toggle the amplifier between the
“Standby” and “Operate” states, duplicating the
action of the front-panel switch.
When using the trigger input, the front panel
switch is still operative. However, operating the
unit with the front panel switch may put the unit
out of “sync” with the control device. If this
should occur, simply press the front panel switch
again to restore “sync”.
Break-In
100 to 500 hours of music
played through the system will
ensure full break-in.
Due to the manufacturing processes used for the
printed circuit boards, wires, and capacitors, a
break-in period is necessary for the amplifier to
reach its full performance potential.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Numbers and
Specifications
Power Output
150 watts per channel continuous into 8 ohms
300 watts per channel continuous into 4 ohms
Input Impedance
100 kΩ – unbalanced inputs
200 kΩ – balanced inputs (100 kΩ per phase)
XLR Input Polarity
Pin 1 = Ground
Pin 2 = Non-inverting (Positive)
Pin 3 = Inverting (Negative)
Gain
Frequency Response
Power Consumption
26 dB
DC - 200 kHz
20 watts in standby mode
120 watts in operating mode, no signal
Dimensions
Weight
17-¼" W x 16" D x 7-¾" H
44 cm x 41 cm x 20 cm
55 pounds
25 kg
9
Download from Www.Somanuals.com. All Manuals Search And Download.
In Case of
Trouble
The Ayre V-5xe provides comprehensive protection
for both the amplifier and your loudspeakers,
including faults that may occur in your source
components.
Overheating
Sensors located on each audio
module will shut the amplifier
off if the heatsink temperature
reaches 175° F (80° C).
If the unit is operated at high playback levels with
insufficient ventilation, the internal temperature
may become too high, triggering the thermal
protection circuitry. In this case, the amplifier will
shut down, the front panel status LED will display
both the red and green elements simultaneously,
and the front panel switch will be inoperative.
If overheating occurs, be sure
to correct the cause before
continuing to use the
amplifier.
Once the unit has cooled, the red LED element will
go out, leaving the unit in the green “Standby”
condition. To restore the unit to the blue “Operate”
mode, simply press the front panel button.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Rail Fuses
Indicator LEDs on the rear of
the unit will glow red when
one of the fuses fails. Please
refer fuse replacement to a
qualified service technician.
Internal fuses on the power supply rails of each
channel protect the loudspeakers from excessive
current, as well as the amplifier from short-circuits.
There are two rail fuses per channel. If either one of
the rail fuses fail, that channel will fail to operate.
The front panel LED will typically continue to
glow blue if both fuses in one channel fail, while it
change to red if only one of the fuses fails.
Therefore the front panel LED is not a reliable
indicator of blown rail fuses. Instead refer to the
fuse status LEDs on the rear panel of the
amplifier.
Do not remove the amplifier cover.
Hazardous voltages may exist inside
the unit.
Use of rail fuses other than a 5 x 20
mm fast-acting 10 ampere unit may
damage the unit and void the
warranty.
AC Line Voltage
If the AC line voltage drops below 80% of normal
(brown-out), the unit will revert to the red
“Warm-Up” mode with the outputs muted. After
the voltage returns to normal, the initial warm-up
cycle will begin again and the unit will then revert
to the green “Standby” mode. Press the front panel
button to return the unit to the blue “Operate”
mode.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
DC Offset
The Ayre V-5xe incorporates a circuit to detect the
presence of DC at the output terminals. In this
situation, the amplifier reverts to the red
“Warm-Up” mode, and power is immediately
removed from the output stage.
After correcting the suspected fault condition, a
press of the front panel button is required to return
the unit to the green “Standby” condition. A second
press of the button will restore the unit to the blue
“Operate” mode. If the fault is still present when the
front panel switch is pressed the second time, the
unit will immediately revert to the red “Warm-Up”
mode.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Statement of
Warranty
North American Warranty
Your Ayre V-5xe amplifier is warranted against
defects in workmanship and materials for a period of
ninety days from the date of original purchase. This
ninety-day coverage is automatic upon acceptance of
delivery and no registration is required.
Additionally you have the option, at no cost, to
extend the warranty for a period of five years from
the date of purchase by returning the completed
Warranty Registration Card and a photocopy of
your original purchase receipt in the enclosed
postage-paid envelope to Ayre within thirty days of
product delivery. This optional warranty is only
available within the thirty-day registration period.
North American Warranty Statement
1. If any defects are found in the materials or
workmanship of this Ayre product within the
warranty period, the unit will be repaired or
replaced by Ayre Acoustics, Inc. (Ayre) or its
authorized agent.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Purchaser must return the product, packed in the
original shipping carton, freight prepaid to:
Ayre Acoustics, Inc.
2300-B Central Avenue
Boulder, Colorado 80301
or to Ayre’s authorized agent. The product must be
accompanied by a written description of the defect
and a photocopy of your original purchase receipt.
Ayre will not be responsible for any shipping
damage and strongly recommends the purchase of
shipping insurance.
3. Ayre reserves the right to inspect any product
that is the subject of any warranty claim prior to
repairing or replacing it. Final determination of
warranty coverage lies solely with Ayre.
Out-of-warranty claims will be billed for labor,
materials, return freight, and insurance as required.
Any product for which a warranty claim is accepted
will be returned to the purchaser and the cost of
shipping and insurance will be factory prepaid
within the boundaries of the USA. Units to be
shipped outside of the USA will be shipped freight
collect only.
4. Ayre strives to manufacture the finest possible
equipment, and therefore reserves the right to make
improvements on its products, without necessarily
assuming any obligation to retrofit such changes
upon its previously manufactured models.
5. The above warranty is the sole warranty given by
Ayre, and is in lieu of all other warranties. All
14
Download from Www.Somanuals.com. All Manuals Search And Download.
implied warranties, including warranties of
merchantability or fitness for any particular purpose
shall be strictly limited to the duration of the above
warranty. Ayre shall have no further obligation of
any kind, whether express or implied. Further, Ayre
shall in no event be obligated for any incidental or
consequential damages as a result of any defect or
any warranty claim, whether express or implied.
6. Ayre does not authorize any third party,
including any dealer or sales representative, to
assume any liability of Ayre or make any warranty
for Ayre. The unit must not have been altered or
improperly serviced. The serial number on the unit
must not have been altered or removed.
7. This warranty is transferable to subsequent
purchasers within the original warranty period.
International Warranty
Warranty terms outside of North America may vary.
Please contact the authorized Ayre distributor in
your country of purchase for the terms of warranty
and also the service itself.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
A Place for
Notes
Serial Number:
________________________________________
Purchase Date:
Dealer:
________________________________________
________________________________________
________________________________________
Salesperson:
16
Rev. 1.2
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Ayre Acoustics, Inc.
2300-B Central Avenue
Boulder, Colorado 80301
+1-303-442-7300
Download from Www.Somanuals.com. All Manuals Search And Download.
|