Day/Night Sensor
The day/night sensor is configured in the factory for optimal performance in a range of conditions.
However, settings can be adjusted to suit specific conditions on site.
To adjust the sensitivity of the day/night sensor, turn the potentiometer until it reaches the desired
threshold. Turn the potentiometer clockwise to increase the threshold and advance the switch to
night mode. Turn the potentiometer counterclockwise to decrease the threshold and delay the
switch to night mode. The switch to night mode will activate the illuminators (sold separately).
Technical Specifications
Function/group
Item
Specifications
Power supply
Model
AXIS Q87-E Power Supply 230 V AC
AXIS Q87-E Power Supply 120 V AC
General
Operating con- -30 °C to 45 °C (-22 °F to 113 °F)
ditions
Humidity 50% – 100% RH (condensing)
Overvoltage
II
Category (OVC)
Fuses
AXIS Q87-E Power Supply 230 V AC: F1 = 2 AT, F2 = 8 AT
AXIS Q87-E Power Supply 120 V AC: F1 = 3,15 AT, F2 = 8 AT
Approvals
EN 55022 Class A, EN 55024,
EN 61000-6-1, EN 61000-6-2
FCC Part 15 Subpart B Class A demonstrated by compliance with
EN 55022
ICES-003 Class A demonstrated by compliance with EN 55022
C-tick AS/NZS CISPR 22 demonstrated by compliance with EN 55022
EN 61000-3-2, EN 61000-3-3
EN 60950-1, EN 60950-22
IEC/EN 60529 IP66
Weight
4 kg (8.8 lb.)
Dimensions
(HxWxD)
278 mm x 242 mm x 90.5 mm (10.9” x 9.5” x 3.6”)
Further Information
guides.
Warranty
For information about Axis’ product warranty and thereto related information, see
Download from Www.Somanuals.com. All Manuals Search And Download.