American Standard Plumbing Product 7415801 User Manual

Installation  
Instructions  
7420  
PORTSMOUTH™  
7420.801  
7420.821  
Series  
Spread Lavatory Faucet  
with Speed Connect™ Drain  
Congratulations on purchasing your  
American Standard faucet with  
7415.801  
7415.821  
Series  
Speed Connect drain, a feature found  
onlyon American Standard faucets.  
Speed Connect Drain*  
• Fewer parts, installs in less time  
• Never needs adjustment  
7415  
Certified to comply with ANSI A112.18.1  
• Guaranteed to seal properly the first time, every time.  
M965015 REV.1.7  
*Your new American Standard faucet is designed to work only with the Speed Connect drain.  
Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions.  
To ensure that your installation proceeds smoothly-please read these instructions carefully  
before you begin.  
Recommended tools  
Tubing Cutter  
Screwdriver  
Channel Locks  
Adjustable Wrench  
Turn off hot and cold water  
supplies before beginning.  
INSTALL SPOUT  
CAUTION  
1
Fig. A.  
Insert SPOUT (1) and CABLE CONNECTOR (12) through center hole, making sure  
the SEAL WASHER (3) is properly seated in the SPOUT ESCUTCHEON (2).  
Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT  
SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting  
hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.  
1
2
3
7
Tighten LOCKNUT (6) firmly. Fig. A.  
INSTALL VALVE BODY  
1A  
Place RUBBER RING (9) into ADAPTER (10).  
4
5
Install LOCKNUT (11) onto VALVE BODY (8).  
SLOT  
From under side of mounting surface, install VALVE BODY (8) through valve  
mounting holes. Threads of VALVE BODY (8) should extent at least 5/16  
of a inch above mounting surface top. Fig. B. Thread ADAPTER (10)  
onto VALVE BODY (8) until snug against internal stop. If necessary, adjust  
LOCKNUT (11).  
6
Hand tighten LOCKNUT (11) to secure VALVE BODY (8).  
Repeat above steps for opposite VALVE BODY (8A).  
12  
1
10  
9
10  
9
MOUNTING  
SURFACE  
5/16'' MIN.  
8A  
Fig. B.  
11  
8
8
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
ATTACH CABLE CONNECTOR  
7
8
Fig. A.  
Fig. B.  
Thread CABLE CONNECTOR (1) clockwise  
onto DRAIN BODY CONNECTION (2) and  
hand tighten. Fig. A.  
1
Your new POP-UP DRAIN installation is  
now complete. Fig. B.  
Note: Tailpeice on pop-up drain is 1-1/4” O.D.  
Fig. B.  
2
1-1/4” O.D.  
CHECK OPERATION OF POP-UP  
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and  
closes.  
1
Note: If STOPPER (2) does not open and close properly then refer  
to the “troubleshooting section” of these instructions.  
2
MAKE WATER SUPPLY AND WASTE CONNECTIONS  
9
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED  
AND MUST BE PURCHASED SEPARATELY.  
Thread TEE BODY (4) to SPOUT SHANK (5).  
Thread HOSE CONNECTOR (6, 6A) to VALVE CONNECTIONS (7, 7A).  
Connect water supply to VALVE BODIES (1,1A) with 1/2" IPS FLEXIBLE  
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use  
adjustable wrench to tighten connections. Do not over tighten.  
Be careful not to kink copper supply when bending. Use tubing  
cutter to cut to proper length.  
5
1A  
7A  
Connect HOT water supply to inlet of left SHANK and COLD  
water supply to right SHANK using sealant, appropriate  
connectors, and COUPLING NUTS.  
6A  
COUPLING  
NUT  
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to  
3
1
waste outlet.  
3/8 O.D.  
BULL-NOSE  
RISERS  
7
4
1/2" PIPE THREAD  
6
COMPRESSION  
NUT  
WASTE  
OUTLET  
FERRULE  
2
FLEXIBLE  
SUPPLIES  
COLD  
HOT  
3/8 COMPRESSION  
CONNECTION  
M965015 REV.1.7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
INSTALL HANDLES  
10  
Push ADAPTER (1) on VALVE STEM (2), so that the hole of the  
ADAPTER (1) with the spline is facing up. Fig. A. Tighten  
STEM SCREW (3) to secure ADAPTER (1).  
THREAD ON  
TO DECK  
ADAPTER  
4
Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting  
male teeth on ADAPTER (1) to female teeth in HANDLE (4).  
SPLINE  
END UP  
1
Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5)  
until snug against mounting surface.  
3
2
Fig. A.  
BOTTOM  
5
TEST INSTALLED FITTING  
11  
5
1
With HANDLES (1) in OFF position, turn on WATER  
SUPPLIES (2) and check all connections for leaks.  
Remove AERATOR (3).  
Operate both HANDLES (1) to flush water  
lines thoroughly.  
1
Replace AERATOR (3).  
3
4
CHECK DRAIN CONNECTIONS  
12  
Operate POP-UP KNOB (5) and fill Sink with water. Check  
that DRAIN STOPPER (4) makes a good seal and retains  
water in Sink. If STOPPER (4) does not seal properly, please  
refer to “Troubleshooting Guide” in these instructions.  
WASTE  
OUTLET  
Release POP-UP KNOB (5) down and check all drain  
2
connections and "P" trap for leaks.  
Tighten  
if necessary.  
COLD  
“P” TRAP  
2
HOT  
CARE INSTRUCTIONS:  
SERVICE (all models)  
13  
14  
HANDLE  
ASSEMBLY  
To change direction of handle rotation,  
proceed as follows:  
DO: SIMPLY RINSE THE PRODUCT  
CLEAN WITH CLEAR WATER.DRY  
WITH A SOFT COTTON FLANNEL  
CLOTH.  
UNTHREAD  
Turn valve to OFF position. Unthread HANDLE  
BASE (1) from DECK ADAPTER (2).  
1
Pull HANDLE ASSEMBLY off VALVE STEM (3).  
Remove SPRING CLIP (4). Lift STOP WASHER (5),  
turn 90˚ and replace. Replace SPRING CLIP (4).  
DO NOT: DO NOT CLEAN THE  
PRODUCT WITH SOAPS, ACID,  
POLISH, ABRASIVES, HARSH  
CLEANERS, OR A CLOTH WITH  
A COARSE SURFACE.  
Find correct position of HANDLE ASSEMBLY by adjusting  
male teeth on VALVE STEM (3) to female teeth in HANDLE.  
Thread HANDLE ASSEMBLY onto DECK ADAPTER (2)  
90˚  
3
5
until snug against mounting surface.  
4
If spout drips, operate handles several times from  
OFF to ON position. Do not force - handles turn  
only 90˚.  
2
M965015 REV.1.7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Speed Connect™ Drain  
Troubleshooting Guide  
If sink does not hold water even though Stopper is in the “down” position:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If Stopper does not raise up fully or sink drains too slowly:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If you need to remove the Stopper:  
• Follow STOPPER REMOVAL PROCEDURE.  
If you would like the ability to remove your Stopper simply by lifting it out of the drain:  
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.  
CABLE ADJUSTMENT PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as  
“Cam” in the illustration. Fig. B.  
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the  
Stopper should be in the UP position. Fig. B, C.  
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.  
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the  
Drain Body Connection (2) and hand-tighten. Fig. A.  
DOWN  
Fig. A.  
Fig. B. Fig. C.  
CAM  
1
LIFT-KNOB  
RE-ATTACH  
CAM CAP  
STOPPER  
DISCONNECT  
2
STOPPER REMOVAL PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled  
as “Cam” and “Cam Cap” in the illustration. Fig. B.  
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.  
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.  
The Stopper can now be removed by lifting it out of the Drain. Fig. F.  
Fig. D.  
Fig. E.  
Fig. F.  
REMOVE  
CAM  
REMOVE  
CAM CAP  
M965015 REV.1.7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
STOPPER INSTALLATION PROCEDURE  
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be  
removed) or “Unlock” Mode (Stopper is removable).  
Locked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. G.  
Fig. G.  
LOGO  
To install the stopper in “Locked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the rear of the  
Sink and the American Standard logo is facing front. Rotate  
Stopper slightly if necessary so that the Stopper slides all the  
way down.Fig. G.  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
REAR OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
Troubling Shooting Guide to complete installation. Stopper will be  
in “Locked” mode and not be removable.  
Locked Mode  
(Vandal Proof)  
Unlocked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. H.  
Fig. H.  
LOGO  
To install the stopper in “Unlocked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the front of the  
Sink and the American Standard logo is facing rear. Rotate Stopper  
slightly if necessary so that the Stopper slides all the way down.  
Fig. H.  
180˚  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
FRONT OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
“Troublingshooting Guide” to complete installation. Stopper will be  
in “Unlocked” mode and removable.  
Unlocked Mode  
Fig. J.  
Fig. K.  
CAM  
INSTALL CAM  
INSTALL  
CAM CAP  
M965015 REV.1.7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
PORTSMOUTH™  
Spread Lavatory Faucet  
with Speed Connect™ Drain  
MODEL NUMBER  
7420.801  
7420.821  
Series  
M950211-YYY0A  
LIFT ROD & KNOB  
M962946-YYY0A  
CROSS HANDLE  
M962590-YYY0A  
SPOUT KIT  
M962937-YYY0A  
HANDLE  
M922881-YYY0A  
AERATOR  
Replace the "YYY" with  
appropriate finish code  
CHROME  
002  
BLACKENED BRONZE  
OIL RUBBED BRONZE  
SATIN NICKEL  
068  
224  
295  
M911741-0070A  
SEAL  
M962592-0070A  
DECK ADAPTER KIT  
M961733-0070A  
SPOUT MTG. KIT  
918555-0070A  
HANDLE SCREW  
918049-0070A  
ADAPTER  
M962544-YYY0A  
STOPPER  
ASSEMBLY  
994053-0070A  
CARTRIDGE  
M952430-0070A  
CABLE ASSEMBLY  
A906652-0070A  
ATTACHMENT NUT  
M962457-YYY0A  
FLANGE  
ASSEMBLY  
M953006-0070A  
TEE & HOSE KIT  
M922872-0070A  
CAM SEAT INSERT  
M962552-0070A  
CAM ASSEMBLY  
M913207-0070A  
TAILPIECE INSERT  
M919660-0020A  
6” TAILPIECE  
(NOT INCLUDED  
WITH FAUCET)  
024220-0070A  
SUPPLY NUT  
A919661-0020A  
TAILPIECE  
M952425-YYY0A  
DRAIN ASSEMBLY  
M962458-0070A  
DRAIN MOUNTING KIT  
HOT LINE FOR HELP  
For toll-free information and answers to your questions, call:  
1-800-442-1902  
Weekdays 8:00 a.m. to 6:00 p.m. EST  
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)  
Weekdays 8:00 a.m. to 7:00 p.m. EST  
IN MEXICO 01-800-839-1200  
Product names listed herein are trademarks of American Standard Inc.  
©
AS America, Inc. 2010  
M965015 REV.1.7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
PORTSMOUTH™  
Spread Lavatory Faucet  
with Speed Connect™ Drain  
MODEL NUMBER  
7415.801  
7415.821  
Series  
M962455-YYY0A  
LIFT ROD & KNOB  
M962946-YYY0A  
CROSS HANDLE  
M962052-YYY0A  
SPOUT KIT  
M962947-YYY0A  
HANDLE  
M922881-YYY0A  
AERATOR  
Replace the "YYY" with  
appropriate finish code  
M962453-YYY0A  
CHROME  
002  
SEAL & ESCUTCHEON  
BLACKENED BRONZE  
OIL RUBBED BRONZE  
SATIN NICKEL  
068  
224  
295  
M962592-0070A  
DECK ADAPTER KIT  
M961733-0070A  
SPOUT MTG. KIT  
918555-0070A  
HANDLE SCREW  
918049-0070A  
ADAPTER  
994053-0070A  
CARTRIDGE  
M962544-YYY0A  
STOPPER  
ASSEMBLY  
A906652-0070A  
ATTACHMENT NUT  
M952430-0070A  
CABLE ASSEMBLY  
M953006-0070A  
TEE & HOSE KIT  
M962457-YYY0A  
FLANGE  
ASSEMBLY  
M922872-0070A  
CAM SEAT INSERT  
M962552-0070A  
CAM ASSEMBLY  
024220-0070A  
SUPPLY NUT  
M913207-0070A  
TAILPIECE INSERT  
M919660-0020A  
6” TAILPIECE  
(NOT INCLUDED  
WITH FAUCET)  
A919661-0020A  
TAILPIECE  
M952425-YYY0A  
DRAIN ASSEMBLY  
M962458-0070A  
DRAIN MOUNTING KIT  
HOT LINE FOR HELP  
For toll-free information and answers to your questions, call:  
1-800-442-1902  
Weekdays 8:00 a.m. to 6:00 p.m. EST  
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)  
Weekdays 8:00 a.m. to 7:00 p.m. EST  
IN MEXICO 01-800-839-1200  
Product names listed herein are trademarks of American Standard Inc.  
©
AS America, Inc. 2010  
M965015 REV.1.7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8

Adcom Stereo Amplifier GFP 715 User Manual
Addonics Technologies Computer Hardware CRT535PES User Manual
AEG Clothes Dryer T76280AC User Manual
AIPTEK Camcorder V2T6 User Manual
Atlona Car Amplifier AT PA100 G2 User Manual
Audiovox Remote Starter APA 800a User Manual
Behringer Satellite Radio TU100 User Manual
Behringer Speaker System B2031P User Manual
Beko Flat Panel Television Plasma TV User Manual
Beko Freezer BZ 77F User Manual