American Standard Laptop Docking Station 7440101 User Manual

Installation  
Instructions  
7440.101  
QUENTIN™  
MONOBLOCK LAVATORY  
FAUCET with Speed Connect™ Drain  
Congratulations on purchasing your American Standard  
faucet with Speed Connect drain, a feature found only  
on American Standard faucets.  
Speed Connect Drain*  
• Fewer parts, installs in less time  
• Never needs adjustment  
• Guaranteed to seal properly the first time, every time.  
Certified to comply with ANSI A112.18.1  
*Your new American Standard faucet is designed to work only with the Speed Connect drain.  
To ensure that your installation proceeds smoothly-please read these instructions carefully  
before you begin.  
M965227  
Recommended tools  
Screwdriver  
Channel Locks  
Adjustable Wrench  
Turn off hot and cold water  
supplies before beginning.  
CAUTION  
INSTALL FAUCET  
1
Installation with ESCUTCHEON PLATE: Apply a light bead of plumbers putty  
to underside of ESCUTCHEON PLATE (9) if mounting surface is uneven. Place ESCUTCHEON  
PLATE (9) onto sink or mounting surface. Feed FAUCET SUPPLIES (3), MOUNTING  
STUD (4) and DRAIN CABLE ASSEMBLY (8) through ESCUTCHEON PLATE and PUTTY  
PLATE (9) and mounting hole of lavatory or mounting surface. Fig. A.  
Installation less ESCUTCHEON PLATE:  
Seat SEAL (1) into under side of FAUCET BASE (2).  
Fig. A.  
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN  
CABLE ASSEMBLY (8) through the mounting hole of lavatory or  
mounting surface. Fig. B.  
9
2
1
GROOVE  
(FAUCET  
BASE)  
PUTTY  
IF REQUIRED  
7
5
3
4
Fig. B.  
6
4
MOUNTING SURFACE  
COLLAR ON  
MOUNTING NUT  
Fig. C.  
From below, push GASKET (7) and RETAINING WASHER (5) onto  
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),  
pulling faucet to front of sink, so SUPPLIES (3) rests against  
mounting hole. Before final tightening, make sure collar on  
MOUNTING NUT (6) is seated into RETAINING WASHER (5).  
Fig. C .  
8
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)  
to complete faucet mounting.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTACH CABLE CONNECTOR  
7
8
9
Fig. A.  
Fig. B.  
Thread CABLE CONNECTOR (1) clockwise  
onto DRAIN BODY CONNECTION (2) and  
hand tighten. Fig. A.  
1
Your new POP-UP DRAIN installation is  
now complete. Fig. B.  
Note: Tailpeice on pop-up drain is 1-1/4” O.D.  
Fig. B.  
2
1-1/4” O.D.  
CHECK OPERATION OF POP-UP  
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and  
closes.  
1
Note: If STOPPER (2) does not open and close properly then  
refer to the “troubleshooting section” of these instructions.  
2
MAKE WATER SUPPLY AND WASTE CONNECTIONS  
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.  
Connection on fitting supplies are 3/8" compression. Connect  
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply  
to COLD (2) wall supply.  
Faucet supplies are 20" long from faucet base.  
Note: If additional supply length is required, installer must  
purchase additional parts separately.  
Important: If SUPPLY HOSES (1, 2) are to long, loop as  
illustrated to avoid kinking.  
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to  
waste outlet.  
APPROX. 20"  
2
BLUE  
BAND  
1
RED  
BAND  
3/8" COMPRESSION  
HOT  
COLD  
M965227  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TEST INSTALLED FITTING  
10  
With HANDLE (1) in OFF position, turn on WATER  
SUPPLIES (2) and check all connections for leaks.  
OFF  
ON  
Remove AERATOR (3).  
COLD  
HOT  
3
Operate HANDLE (1) to flush water lines thoroughly.  
Replace AERATOR (3).  
1
CHECK DRAIN CONNECTIONS  
Operate POP-UP KNOB (4) and fill lavatory with water.  
Check that DRAIN STOPPER (5) makes a good seal  
and retains water in SINK. If DRAIN STOPPER (5)  
does not seal properly, please refer to Troubleshooting  
section in these instructions.  
5
Release POP-UP KNOB (4) down and check all drain  
connections and "P" trap for leaks.  
if necessary.  
Tighten  
WASTE  
OUTLET  
2
2
“P” TRAP  
Turn off hot and cold water  
supplies before beginning.  
SERVICE  
CAUTION  
11  
To remove or replace cartidge: Fig. A.  
Turn valve to OFF position.  
Remove HANDLE SCREW (2).  
Pull off HANDLE (3) and CAP (4).  
Unthread CARTRIDGE NUT (5) and remove.  
Pull out CARTEIDGE (6).  
Inspect CARTRIDGE (6) and O-RING (7) for  
debris and clean if necessary.  
Clean MANIFOLD (1) and rinse clean.  
Reinstall CARTRIDGE (6) and O-RING (7) onto  
MANIFLOD (1).  
Reinstall CARTRIDGE NUT (5), CAP (4) and  
HANDLE ASSEMBLY (3).  
7
6
5
4
2
3
If spout drips, operate handle several times from  
OFF to ON and HOT to COLD position. Do not  
force handles.  
1
2.5mm HEX KEY  
CARE INSTRUCTIONS:  
12  
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.  
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A  
CLOTH WITH A COARSE SURFACE.  
M965227  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Speed Connect™ Drain  
Troubleshooting Guide  
If sink does not hold water even though Stopper is in the “down” position:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If Stopper does not raise up fully or sink drains too slowly:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If you need to remove the Stopper:  
• Follow STOPPER REMOVAL PROCEDURE.  
If you would like the ability to remove your Stopper simply by lifting it out of the drain:  
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.  
CABLE ADJUSTMENT PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as  
“Cam” in the illustration. Fig. B.  
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the  
Stopper should be in the UP position. Fig. B, C.  
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.  
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the  
Drain Body Connection (2) and hand-tighten. Fig. A.  
Fig. A.  
Fig. B. Fig. C.  
DOWN  
CAM  
1
RE-ATTACH  
CAM CAP  
STOPPER  
DISCONNECT  
2
STOPPER REMOVAL PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled  
as “Cam” and “Cam Cap” in the illustration. Fig. B.  
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.  
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.  
The Stopper can now be removed by lifting it out of the Drain. Fig. F.  
Fig. F.  
Fig. D.  
Fig. E.  
REMOVE  
CAM  
REMOVE  
CAM CAP  
M965227  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
STOPPER INSTALLATION PROCEDURE  
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be  
removed) or “Unlock” Mode (Stopper is removable).  
Locked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. G.  
Fig. G.  
LOGO  
To install the stopper in “Locked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the rear of the  
Sink and the American Standard logo is facing front. Rotate  
Stopper slightly if necessary so that the Stopper slides all the  
way down.Fig. G.  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
REAR OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
DRAIN  
the Cam to make sure it is fully inserted. Fig. K.  
Locked Mode  
(Vandal Proof)  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
Troubling Shooting Guide to complete installation. Stopper will be  
in “Locked” mode and not be removable.  
Unlocked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. H.  
Fig. H.  
LOGO  
To install the stopper in “Unlocked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the front of the  
Sink and the American Standard logo is facing rear. Rotate Stopper  
slightly if necessary so that the Stopper slides all the way down.  
Fig. H.  
180˚  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
FRONT OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Unlocked Mode  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
“Troublingshooting Guide” to complete installation. Stopper will be  
in “Unlocked” mode and removable.  
Fig. J.  
Fig. K.  
CAM  
INSTALL CAM  
INSTALL  
CAM CAP  
M965227  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUENTIN™  
MONOBLOCK LAVATORY  
FAUCET with Speed Connect™ Drain  
MODEL NUMBER  
7440.101  
M962682-0070A  
CARTRIDGE  
M904524 -0070A  
CARTRIDGE NUT  
M907059-YYY0A  
CARTRIDGE COVER  
M922894-YYY0A  
AERATOR  
M964156-YYY0A  
LIFT ROD & KNOB  
M918004-YYY0A  
A911838-0070A  
SEAL  
M952425-YYY0A  
DRAIN ASSEMBLY  
SET SCREW  
M964143-YYY0A  
HANDLE KIT  
M962492-0070A  
MOUNTING KIT  
M962544-YYY0A  
STOPPER  
ASSEMBLY  
M918462-0070A  
CABLE ADAPTER  
M952430-0070A  
CABLE ASSEMBLY  
M962457-YYY0A  
FLANGE  
ASSEMBLY  
M907671-YYY0A  
ESCUTCHEON  
M922872-0070A  
CAM SEAT INSERT  
M962552-0070A  
CAM ASSEMBLY  
M913207-0070A  
TAILPIECE INSERT  
Replace the "YYY" with  
appropriate finish code  
002  
224  
295  
CHROME  
OIL RUBBED BRONZE  
SATIN NICKEL  
A919661-0020A  
TAILPIECE  
M962458-0070A  
DRAIN MOUNTING KIT  
HOT LINE FOR HELP  
M919660-0020A  
6” TAILPIECE  
For toll-free information and answers to your questions, call:  
1 (800) 442-1902  
Weekdays 8:00 a.m. to 6:00 p.m. EST  
(NOT INCLUDED  
WITH FAUCET)  
IN MEXICO 01-800-839-1200  
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)  
Weekdays 8:00 a.m. to 7:00 p.m. EST  
Product names listed herein are trademarks of American Standard Inc.  
©
AS America,Inc. 2011  
M965227  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

3M Intercom System 2470 User Manual
Aigo MP3 Player UM F158 User Manual
Aiwa CD Player NSX AJ22 User Manual
Alliance Laundry Systems Washer Topload Washer User Manual
Avsar Emaye San Tic AS DVD Recorder DVD Copy User Manual
Bakers Pride Oven Fryer LGF User Manual
Bang Olufsen Cable Box 26 Jun User Manual
Barco Musical Toy Instrument R9843115 User Manual
BB Electronics Computer Hardware 232CC1A User Manual
Eureka Tents Vacuum Cleaner 79 SERIES User Manual