American Standard Indoor Furnishings 0485013 User Manual

HEXALYN™  
COUNTERTOP SINK  
VITREOUS CHINA  
BARRIER FREE  
HEXALYN™ COUNTERTOP SINK  
• Made from vitreous china  
• Self-rimming with cutout template supplied  
• Front overflow  
• Faucet ledge  
Shown with 4801.862 Amarilis/Heritage faucet  
with Triune handles (not included)  
0485.013 Faucet holes on 8" (203mm) centers  
(Illustrated)  
0485.027 Faucet holes on 4" (102mm) centers  
0485.033 Center hole only  
Nominal Dimensions:  
543 x 489mm  
(21-3/8" x 19-1/4")  
610mm  
(24)  
51mm  
203mm  
(8)  
(2)  
OPTIONAL  
Bowl sizes:  
432mm (17") wide  
305mm (12") front to back  
73mm  
(2-7/8)  
FINISHED  
WALL  
OR  
184mm  
(7-1/4)  
SPLASH BACK  
152mm (6") deep  
203mm  
(8)  
MIN.  
DRAWING FOR  
DIMENSIONAL  
PURPOSES ONLY.  
IT IS NOT AN EXACT  
REPRESENTATION.  
489mm  
(19-1/4)  
Compliance Certifications -  
Meets or Exceeds the  
Following Specifications:  
• ASME A112.19.2M for  
851mm  
(33-1/2)  
686mm  
(27)  
MIN.  
543mm  
(21-3/8)  
Vitreous China Fixtures  
152mm  
(6)  
MAX.  
COUNTERTOP (BY OTHERS)  
SEALING  
COMPOUND  
11mm  
(7/16)  
BARRIER FREE  
CLEARANCE  
229mm  
(9)  
182mm  
(7-3/16)  
*
273mm  
(10-3/4)  
MIN.  
To Be Specified:  
Color: White Bone  
Linen Silver  
Fawn Beige Black  
Faucet*:  
327mm  
(12-7/8)  
*
178mm  
(7)  
203mm  
(8)  
SUPPLIES  
AS REQ'D.  
787mm (31)  
851mm (33-1/2)  
1-1/4 O.D.  
WASTE  
FINISHED  
FLOOR  
Faucet Finish:  
Supplies:  
1-1/4 O.D.  
TAILPIECE  
1-1/4" Trap:  
* See faucet section for additional models available  
NOTES:  
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES  
AND ANSI A117.1 ACCESSIBLE AND USABLE  
BUILDINGS AND FACILITIES - CHECK LOCAL CODES.  
Install lavatory 864mm (34") from finished floor.  
Lavatory installed 51mm (2") minimum from front edge  
of countertop provides 686mm (27") knee clearance area.  
DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TRAP ARE  
*
SUGGESTED  
FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED  
SEPARATELY.  
FOR COUNTERTOP CUTOUT AND INSTALLATION INSTRUCTIONS USE  
TEMPLATE SUPPLIED WITH SINK.  
SEALING COMPOUND SUPPLIED BY OTHERS.  
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range  
of tolerances established by ANSI Standard A112.19.2.  
These measurements are subject to change or cancellation. No responsibility is  
assumed for use of superseded or voided pages.  
J36  
© 2008 AS America Inc.  
Revised 2/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acnodes Computer Hardware M3716 User Manual
Acnodes Personal Computer RMC 7132 User Manual
Air King Ventilation Hood AK150LS User Manual
Alcatel Lucent Network Card 1511 BA User Manual
Amana Microwave Oven RMC 720A User Manual
American Standard Outdoor Shower 2064724 User Manual
AMX Stereo Receiver Delta Series User Manual
Bakers Pride Oven Convection Oven GDCO E1 Single User Manual
Baracoda Projector L 1D User Manual
Behringer Music Mixer TRUTH B1031 User Manual