American Standard Hot Tub 7236XXXW User Manual

7236.XXXW  
SERIES WHIRLPOOL  
VIRTUOSO™  
HIGH GLOSS ACRYLIC  
SHOWN LESS ALL FITTINGS  
INSTALLATION INSTRUCTIONS  
1829mm  
(72)  
914mm  
(36)  
19mm  
(3/4)  
TYP.  
THANK YOU...  
for selecting an American Standard bath. Your new  
914mm  
(36)  
bath is shipped to you after careful inspection. The  
PUMP  
whirlpool version is completely assembled with pump,  
motor, and system piping. All you need to finish the  
installation are your selected fittings and electrical  
connections for a whirlpool.  
178mm X 356mm  
(7 x 14) CUTOUT  
To insure maximum performance and pleasure from  
this product, please follow the instructions and  
cautions.  
C/L OF  
DRAIN  
102mm  
(4)  
470mm  
(18-1/2)  
279mm  
(11)  
ON/ OFF  
SWITCH  
RECOMMENDED  
FITTING LOCATION  
64 X 279mm (2-1/2 X 11)  
List of Optional Components (not included):  
• 6 Foot Apron 0727.200*  
C/L OF  
OVERFLOW  
SAFE-T-HEATER  
51mm  
(2)  
• Safe-T-Heater 9075.120*  
REMOVABLE BLANK  
• Tile Bead Kit 751755-100*  
76mm  
(3)  
List of Required Components (not included):  
489mm  
(19-1/4)  
• Drain 1583.470*  
• Bath Filler*  
LEVELING  
STRINGER  
NOT FOR  
SUPPORT  
540mm  
21-1/4  
44mm  
(1-3/4)  
* see your American Standard Distributor  
ROUGH FLOOR  
89mm  
(3-1/2)  
INTEGRAL  
FEET  
1-1/2 N.P.T. THREAD  
1-1/2 O.D.  
TAILPIECE  
List of Required Tools and Supplies:  
GENERAL SPECIFICATIONS FOR 7236 WHIRLPOOL  
INSTALLED SIZE  
WEIGHT  
72 x 36 x 21-1/4 In. (1829 x 914 x 540mm)  
Tools  
Supplies  
101 Lbs. (45 Kg.)  
751 Lbs. (338 Kg.)  
78 Gal. (296 L)  
• Level  
• Nails  
WEIGHT w/WATER  
GAL. TO OVERFLOW  
WHIRLPOOL MIN. OPERATING VOL.  
BATHING WELL AT SUMP  
BATHING WELL AT RIM  
WATER DEPTH TO OVERFLOW  
FLOOR LOADING  
(PROJECTED AREA)  
PTS.  
CUBE (FT3)  
• Tape Measure  
• Pipe Wrench  
• Slip Joint Pliers  
• Screw Driver  
• Standard  
• Putty  
69 Gal. (262 L)  
• Caulking (waterproof)  
• 1 x 3 or 2 x 2  
Stringers  
46 x 18 In. (1168 x 457mm)  
66 x 30-1/2 In. (1676 x 775mm)  
15-3/4 In.(400mm)  
• Drop Cloth  
• 20 amp GFI  
Outlet  
• Cement, Plaster,  
Grout  
42 Lbs./Sq.Ft. (204 Kgs./Sq.m)  
Woodworking Tools  
• Personal Safety  
Equipment  
25.6  
49.4  
WHIRLPOOL ELECTRICAL SPECIFICATIONS  
PUMP  
• Caulking Gun  
2.1 HP,15.6 AMPS,120V.  
GENERAL INSTALLATION INFORMATION  
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor  
immediately.  
After inspection and during installation, protect the bath from construction damage. After installation, and before  
enclosing with wallboard, tile, etc., water test the unit and check for leaks.  
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect  
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,  
motor, or piping system.  
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and  
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead  
(required for recess installations).  
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.  
WARNING! Do not lift whirlpool by the piping harness at any time.  
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.  
© American Standard Inc. 2003  
All product names listed herein are trademarks  
of American Standard Inc. unless otherwise noted.  
750729-100 REV. H  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL INSTALLATION INSTRUCTIONS  
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other  
applicable codes.  
WARNING:  
When using electrical products, basic precautions should always be observed, including the following:  
1. DANGER: RISK OF ELECTRIC SHOCK  
Connect only to a circuit protected by a ground-fault circuit interrupter.  
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.  
3. Install to permit access for servicing.  
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).  
The whirlpool should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be hard-wired from the  
electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded  
neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE  
15 AMP MAXIMUM GFCI CIRCUIT.  
ELECTRICAL INSTALLATION  
SEPERATE  
20 AMP GFCI  
OUTLET  
WHIRLPOOL MOUNTED  
120 VAC  
ELECTRONIC  
SWITCH  
PUMP/MOTOR  
GND.  
ELECTRICAL DIAGRAM  
READ AND FOLLOW ALL INSTRUCTIONS  
(3)  
750729-100 REV. H  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRE SELECTION GUIDE  
Maximum distance from  
fusebox to motor  
The sizes shown on this  
chart are recommendations  
for copper conductors  
only. Always follow  
local and national  
Motor  
Hi Performance  
Rating  
50'  
100'  
120V Power Line  
10  
150'  
200'  
electrical codes  
12  
8
8
2.1  
DRAIN CONNECTION AND SYSTEM TEST  
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the  
pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of  
the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings  
are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is  
connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the  
whirlpool is running.  
POST INSTALLATION CLEAN-UP  
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor.  
Do not use wire brushes or any other metal implement on bath surface.  
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or  
®
stains may be removed using granular Spic and Span mixed with water.  
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.  
HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.  
Abrasive cleaners must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing  
with a white automotive-type polishing compound and waxing with a liquid wax.  
®
(4)  
SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE  
750729-100 REV. H  
Download from Www.Somanuals.com. All Manuals Search And Download.  

2nd Ave Two Way Radio 30 603 Tool User Manual
3Com Network Router 3CRWE754G72 A User Manual
AG Neovo Computer Monitor DR 17 User Manual
Aiphone Car Video System MY CU User Manual
Akai Projection Television PT50DL14 User Manual
ATI Technologies Recording Equipment 137 70480 10 User Manual
Atlona TV Cables AT80HDMI 1 User Manual
Axis Communications Security Camera AXIS M3203 V User Manual
Banner Stereo Amplifier MA3 User Manual
Beko Double Oven DVC665 User Manual