INSTALLATION & OPERATION GUIDE FOR
EVERCLEAN™ / EVOLUTION™
WHIRLPOOLS AND BATHTUBS
MODEL 2422L / V
MODEL 6060L / V
MODEL 2771L / V
MODEL 2645L / V
MODEL 7236L / V
MODEL 2425L / V - LHO
MODEL 2425L / V - RHO
MODEL 2908L
5' x 32"
CORNER
5' x 36"
OVAL
6' x 36"
5' x 32" IA-LHO
5' x 32" IA-RHO
REMINISCENCE
ELLISSE
MODEL 2711L
MODEL 2773L
CADET 6' x 36"
CADET 6' x 42"
CADET CORNER
5' x 32"
MODEL 2774L
MODEL 2775L
MODEL 2732L
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the
whirlpool installation are your selected fittings and electrical connections.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
© AS Americas Inc. 2010
All product names listed herein are trademarks
of AS Americas Inc. unless otherwise noted.
753737-100 Rev. E
1
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, ELECTRIC SHOCK
OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS!
!
!
!
WARNING: Risk of personal injury. Do not permit children to use this unit without adult supervision.
WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting.
WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within
60 inches (1524mm) of this unit.
!
!
!
!
WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse
medical history should consult a physician before using this product.
WARNING: Risk of personal injury. Do not overfill unit before entering. Entering tub when filled more than 2/3
can cause overflow and slippery conditions. Exercise caution when entering and exiting.
WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not
recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or
hyperthermia resulting in loss of consciousness or even drowning.
WARNING: Pregnancy. If you are or think you may be pregnant, consult your physician before using the bathtub.
Never drop or insert any object into any opening.
Use this unit only for its intended use as described in this manual. Do not use any attachments not recommended by
American Standard.
The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI,
push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI
fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button
being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this hydromassage
bathtub. Disconnect the hydromassage bathtub and have the problem corrected by a licensed electrician before using.
A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no. 8 AWG solid
copper bonding conductor between this unit and all other electrical equipment and exposed metal in the vicinity, as
needed to comply with local requirements. To reduce the risk of an electric shock, connect this connector the
grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors
supplying this unit.
SAVE THESE INSTRUCTIONS
753737-100 Rev. E
3
Download from Www.Somanuals.com. All Manuals Search And Download.
General Installation Information
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your
vendor immediately. After inspection and during installation, protect the bath from construction damage. Before
installation, and before enclosing with wallboard, tile, etc., the bath must be filled with water and operated to
check for leaks that may have resulted from shipping damage or mishandling! Do not make modifications to
the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance
of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others.
For electrical requirements, refer to section titled “Whirlpool Electrical Installation Instructions”.
Check for availability of optional American Standard wall tiling bead (required for recess installation).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
!
WARNING: Do not lift whirlpool by the piping harness at any time.
List of Required Tools and Supplies:
Tools
Supplies
• Level
• Nails
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Putty
• Caulking (waterproof)
• 1 x 4 Stringers
• Drop Cloth
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
• Cement, Plaster, Grout
LIST OF OPTIONAL COMPONENTS (NOT INCLUDED):
Required Components
(Not Included)
Optional Components
(Not Included)
Description
Model
Number
E-Z
Install
Heater
Tile
Bead
Kit
Drain
(White)
•
Drain
•
Apron
Kit
(Specify
Finish)
NOT
Everclean™/Evolution™ Corner
6060
1599.500.020
1583.470.XXX
INCLUDED
√
√
√
√
AVAILABLE
Everclean™/Evolution™ 5' x 32"
Everclean™/Evolution™ 5' x 36"
Everclean™/Evolution™ 6' x 36"
Everclean™/Evolution™ 5' x 32" IA
Everclean™/Evolution™ Oval
Everclean™ Reminiscence
Everclean™ Ellisse
2422
2771
7236
2425
2645
2908
2711
2773
2774
2775
2732
1599.500.020* 1599.205.XXX*
1599.500.020* 1599.205.XXX*
1599.500.020* 1599.205.XXX*
1599.500.020* 1599.205.XXX*
9261.019
9261.019
9271.019
INTEGRAL
9266.018
√
√
√
√
√
√
√
√
√
√
√
N/A
√
1599.500.020
1599.500.020
1599.500.020
1599.500.020
1599.500.020
1599.500.020
1599.500.020
1583.470.XXX
1583.470.XXX
1583.470.XXX
1583.470.XXX
1583.470.XXX
1583.470.XXX
1583.470.XXX
NOT
N/A
√
AVAILABLE
NOT
AVAILABLE
Everclean™ Cadet 6' x 36"
Everclean™ Cadet 6' x 42"
Everclean™ Cadet Corner
Everclean™ 5' x 32"
√
√
√
√
9272.018
9272.018
NOT
AVAILABLE
5FT-
APRON
• For these components please see your Vendor.
* These models require American Standard Lifetime™ Drain 1599.205 or 1599.500
753737-100 Rev. E
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR LIFETIME / EVOLUTION WHIRLPOOLS AND BATH TUBS
Description
Dimensions
L-W-H
Drain /
Overflow
Height to
Underside
of Deck: C
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product
Apron /
Heater Ready Gallon to Whirlpool
Weight Mounting
for Field
Overflow Operating
Volume
Installation
6060L / V
Corner*
L 1949mm (76-3/4")
A 18"
Template
Provided
5-5/8"
(130mm)
824 lb. (374 kg)/
25 lb./sq.ft.
(117 kg/sq.m)
108 lb.
(49 kg.)
N/A
Included
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
86 gal.
(325 l.)
71 gal.
(269 l.)
C 19-1/2"
(495mm)
Template
751627-400
W 1661mm (65-3/8") (457mm)
H 546mm (21-1/2")
B 13-3/4"
(349mm)
2422L / V
5' x 32"
A 20-1/8"
(511mm)
B 11"
58-1/2"
3-1/4"
(83mm)
690 lb. (313 kg)/
53 lb./sq.ft.
(260 kg/sq.m)
74 lb.
(34 kg.)
Optional
Optional
74 gal.
(280 l.)
33 gal.
(125 l.)
L 1524mm (60")
W 813mm (32")
H 546mm (21-1/2")
60-3/16"
(1528mm)
x 30-1/2"
(774mm)
C 20"
(508mm)
(1485mm)
x 30-1/2"
(774mm)
(279mm)
2771L / V
5' x 36"
A 20-1/8"
(511mm)
B 11"
3-1/4"
(83mm)
800 lb. (363 kg)/
53 lb./sq.ft.
(260 kg/sq.m)
75 lb.
(34 kg.)
87 gal.
(329 l.)
50 gal.
(189 l.)
L 1524mm (60")
W 914mm (36")
H 546mm (21-1/2")
58-1/2"
60-3/16"
(1528mm)
x 34-1/2"
(876mm)
C 20"
(508mm)
(1485mm)
x 34-1/2"
(876mm)
(279mm)
7236L / V
6' x 36"
A 20-1/8"
(511mm)
B 11"
3-1/4"
(83mm)
1031 lb. (467 kg)/ 106 lb. Optional
57 lb./sq.ft.
(280 kg/sq.m)
111 gal.
(420 l.)
53 gal.
(201 l.)
L 1829mm (72")
W 914mm (36")
H 546mm (21-1/2")
70-1/2"
72-3/16"
(1833mm)
x 34-1/2"
(876mm)
C 20"
(508mm)
(48 kg.)
(1790mm)
x 34-1/2"
(876mm)
(279mm)
2425L / V
5' x 32”
LHO /
A 19-1/8"
(485mm)
B 10-1/2"
(266mm)
2-7/8"
(73mm)
675 lb. (306 kg)/
54 lb./sq.ft.
(262 kg/sq.m)
92 lb.
(42 kg.)
Included
Optional
N/A
70 gal.
(265 l.)
39 gal.
(148 l.)
L 1524mm (60")
W 813mm (32")
H 521mm (20-1/2")
C 20-1/4"
(515mm)
N/A
60-3/16"
(1528mm)
x 30-1/2"
(774mm)
RHO
2645L / V
Oval
A 15-1/4"
(387mm)
B 8-1/4"
(209mm)
1-3/4"
(44mm)
580 lb. (263 kg)/
36 lb./pies
cuadrados
96 lb.
(44 kg.)
58 gal.
(219 l.)
42 gal.
(159 l.)
L 1676mm (66")
W 914mm (36")
H 502mm (19-3/4")
C 18-1/4"
(464mm)
64"
(1625mm)
x 34"
66-3/16"
(1681mm)
x 34-1/2"
(876mm)
(175 kg/sq.m)
(863mm)
2908L
Reminiscence
A 15-1/8"
(384mm)
B 13"
6"
659 lb. (299 kg)/
40 lb./sq.ft.
(191 kg/sq.m)
95 lb.
(43 kg.)
68 gal.
(257 l.)
55 gal.
(208 l.)
L 1676mm (66")
W 914mm (36")
H 616mm (24-1/4")
C 18-1/4"
(464mm)
Template
Provided
Template
752540-400
(152mm)
(330mm)
2711L
Ellisse
A 17-3/8"
(441mm)
B 12"
4"
965 lb. (434 kg)/ 148 lb.
40 lb./sq.ft.
(195 kg/sq.m)
N/A
95 gal.
(360 l.)
74 gal.
(280 l.)
L 1829mm (72")
W 1219mm (48")
H 546mm (21-1/2")
C 19-1/2"
(495mm)
70-1/2"
72-3/16"
(1833mm)
x 48"
(102mm)
(67 kg.)
(1791mm)
x 46-1/2"
(1181mm)
(305mm)
(1219mm)
2773L
Cadet 6' x 36"
2-1/4"
(57mm)
751 lb. (341 kg)/ 101 lb.
40 lb./sq.ft.
(190 kg/sq.m)
Optional
Optional
N/A
78 gal.
(296 l.)
L 1829mm (72")
W 914mm (36")
H 502mm (19-3/4")
A 17"
(432mm)
B 12"
C 18-1/4"
(464mm)
70-1/2"
72-3/16"
(1833mm)
x 36"
64 gal.
(243 l.)
(45 kg.)
(1791mm)
x 34-1/4"
(870mm)
(305mm)
(914mm)
2774L
Cadet 6' x 42"
2-1/4"
(57mm)
821 lb. (372 kg)/ 137 lb.
42 lb./sq.ft.
(203 kg/sq.m)
82 gal.
(310 l.)
L 1829mm (72")
W 1067mm (42")
H 502mm (19-3/4")
A 16-1/4" C 18-1/4"
(413mm) (464mm)
B 12"
70-1/2"
72-3/16"
(1833mm)
x 42"
66 gal.
(256 l.)
(62 kg.)
(1791mm)
x 40-1/2"
(1029mm)
(305mm)
(1067mm)
2775L
Cadet Corner
11"
756 lb. (343 kg)/ 130 lb.
(279mm) 34 lb./sq.ft.
75 gal.
(284 l.)
L 2159mm (85")
W 1524mm (60")
H 502mm (19-3/4")
A 16-1/2" C 18-1/4"
(419mm) (464mm)
B 11"
Template
Provided
Template
752539-400
60 gal.
(272 l.)
(59 kg.)
(30 kg.)
(115 kg/sq.m)
(279mm)
2732L
5' x 32"
2-5/8"
(67mm)
524 lb. (237 kg)/ 65 lb.
43 lb./sq.ft.
(213 kg/sq.m)
Optional
55 gal.
(208 l.)
L 1524mm (60")
W 832mm (32-3/4")
H 502mm (19-3/4")
A 17-1/4" C 18-1/4"
(438mm) (464mm)
B 8-1/2"
58-1/2"
60-3/16"
(1529mm)
x 31-1/4"
(794mm)
47 gal.
(155 l.)
(1485mm)
x 31-1/4"
(794mm)
(216mm)
TABLE 1
753737-100 Rev. E
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGHING-IN REFERENCES
5' x 32" (MODEL 2422L / V)
60"
(1524mm)
13-3/4"
(349mm)
3"
(76mm)
32"
(813mm)
6"
(152mm)
CUT OUT IN FLOOR
FOR DRAIN
7-3/4"
(197mm)
PROVIDE
ACCESS TO
PUMP FOR
SERVICING
ON ALL
3-1/4"
(83mm)
11"
(279mm)
INSTALLATIONS
6' x 36" (MODEL 7236L / V)
72"
(1829mm)
11"
(279mm)
3-1/4"
(83mm)
13-3/4"
(349mm)
7-3/4"
(197mm)
3"
(76mm)
36"
(914mm)
6"
(152mm)
CUT OUT IN FLOOR
FOR DRAIN
PROVIDE
ACCESS TO
PUMP FOR
SERVICING
ON ALL
INSTALLATIONS
5' x 36" (MODEL 2771L / V)
60"
(1524mm)
11"
(279mm)
3-1/4"
(83mm)
CUT OUT IN FLOOR
FOR DRAIN
3"
(76mm)
6"
36"
(152mm)
(914mm)
7-1/2"
(191mm)
13-3/4"
(349mm)
PROVIDE
ACCESS TO
PUMP FOR
SERVICING
ON ALL
INSTALLATIONS
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7.
753737-100 Rev. E
6
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGHING-IN REFERENCES
OVAL (MODEL 2645L / V)
66"
(1676mm)
11-1/4"
(286mm)
1-3/4"
(44mm)
18"
(457mm)
36"
(914mm)
6"
(152mm)
CUT OUT IN FLOOR
FOR DRAIN
PROVIDE
3"
ACCESS TO
PUMP FOR
SERVICING
ON ALL
(76mm)
5-3/8"
(137mm)
8-1/4"
(210mm)
INSTALLATIONS
5' x 32" IA-RHO (MODEL 2425L/V-RHO) - shown
5' x 32" IA-LHO (MODEL 2425L/V-LHO)
60"
(1524mm)
10-1/2"
(267mm)
3"
(76mm)
2-7/8"
(73mm)
7-1/2"
(191mm)
16"
(406mm)
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
6"
(152mm)
32"
(813mm)
CUT OUT IN FLOOR
FOR DRAIN
CORNER (MODEL 6060L / V)
13-1/2"
(343mm)
76-3/4"
(1949mm)
54-1/2"
(1384mm)
65-3/8"
(1661mm)
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
3"
(76mm)
10"
(254mm)
15"
(381mm)
17-3/4"
(451mm)
7"
(178mm)
7" (178mm)
5-5/8"
(143mm)
CUT OUT
13-3/4" (349mm)
IN FLOOR FOR DRAIN
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7.
753737-100 Rev. E
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGHING-IN REFERENCES
CADET CORNER (MODEL 2775L)
229 X 305mm
(9 X 12
CUTOUT IN
FLOOR FOR
DRAIN
1080mm
(42-1/2
"
")
"
)
1076mm
(42-3/8
"
)
1524mm
(60
165mm
(6-1/2)
"
)
70mm REF.
(2-3/4)
PROVIDE ACCESS TO
PUMP FOR
SERVICING ON ALL
INSTALLATIONS
RECOMMENDED
FITTING
LOCATION
64 X 330mm
PUMP
(2-1/2 X 13
")
OUTLINE OF
CUTOUT
279mm
(11
")
C/L
1080 mm
C/L OF DRAIN OUTLET
(42-1/2
")
2159mm
(85
ELLISSE (MODEL 2711L)
"
)
1829mm
(72")
(36-1/2
927mm
")
102mm
(4
OUTLINE OF CUTOUT
1791 X 1181
"
)
(70-1/2 X 46-1/2")
"
305mm
(12
"
)
C/L OF
DRAIN
229mm x 356mm
(9 x 14 ) FLOOR
CUTOUT
"
"
1219mm
(48
PUMP
"
)
PROVIDE ACCESS TO
PUMP FOR SERVICE
ON ALL INSTALLATIONS
OPTIONAL DECK
FITTING AREA
RECOMMENDED
FITTING LOCATION
64 X 279mm (2-1/2" X 11")
REMINISCENCE (MODEL 2908L)
1676mm
(66")
330mm
(13
"
)
PUMP
914mm
(36")
229 x 305mm
(9 X 12)
457mm
(18)
FLOOR
CUTOUT
DIMENSIONS OF FIXTURES ARE NOMINAL
AND MAY VARY WITHIN THE RANGE OF
TOLERANCES ESTABLISHED BY
64mm REF.
(2-1/2)
INTEGRAL
FITTING
DECK
ANSI STANDARDS Z124.1 AND A112.19.7.
PROVIDE ACCESS TO
152mm
(6)
OUTLINE OF
CUTOUT
PUMP FOR SERVICE
C/L OF DRAIN
OUTLET
ON ALL INSTALLATIONS
753737-100 Rev. E
8
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGHING-IN REFERENCES
CADET 6' x 42" (MODEL 2774L)
1829mm
(72")
305mm
(12")
RECOMMENDED FITTING LOCATION
64 X 330mm (2-1/2" x 13")
FOR PIER OR ISLAND
229mm
(9")
19mm
(3/4")
INSTALLATIONS ONLY
FINISHED
WALL
PROVIDE
ACCESS TO
PUMP FOR
SERVICING
ON ALL
229mm
(9")
INSTALLATIONS
1067mm
(42")
PUMP
CUTOUT IN FLOOR
FOR DRAIN
533mm
(21")
OUTLINE OF
CUTOUT
1791mm x 1029mm
(70-1/2" X 40-1/2")
(2) AIR VALVES
57mm
(2-1/4")
(8) JETS
ALT. FITTING
LOCATION #1
C/L OF DRAIN
CADET 6' x 36" (MODEL 2773L)
1829mm
(72")
229mm
(9")
305mm
(12")
RECOMMENDED FITTING LOCATION
64 X 330mm (2-1/2" x 13")
FOR PIER OR ISLAND
19mm
(3/4")
INSTALLATIONS ONLY
FINISHED
WALL
908mm
(35-3/4")
PROVIDE
229mm
(9")
ACCESS TO
PUMP FOR
SERVICING
ON ALL
INSTALLATIONS
PUMP
CUTOUT IN FLOOR
FOR DRAIN
454mm
(17-7/8")
OUTLINE
(2) AIR VALVES
57mm
(2-1/4")
OF CUTOUT
(8) JETS
ALT. FITTING
LOCATION #1
1791mm x 870mm
(70-1/2" X 34-1/4")
C/L OF DRAIN
5' x 32" (MODEL 2732L)
60"
(1524mm)
12"
(305mm)
16-1/2"
(419mm)
DIMENSIONS OF FIXTURES ARE NOMINAL
AND MAY VARY WITHIN THE RANGE OF
TOLERANCES ESTABLISHED BY
3"
(76mm)
6"
ANSI STANDARDS Z124.1 AND A112.19.7.
(152mm)
32-3/4"
(832mm)
CUT OUT IN FLOOR
FOR DRAIN
PROVIDE
ACCESS TO
PUMP FOR
SERVICING
ON ALL
5-7/8"
(149mm)
INSTALLATIONS
8-1/2"
(216mm)
753737-100 Rev. E
9
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure
roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump
and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used
as the primary access opening.
1. Position the whirlpool into the installation opening and level the deck in both directions, shimming the integral support feet IF necessary.
Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
2. Remove the whirlpool and attach a 1 x 4 stringer to the studs, with the top of the stringer touching the traced line.
!
The rim of the bath must not support weight.
FIGURE 1
TYPICAL INSTALLATION
3. Install drain components to the whirlpool following the drain installation instructions. Before
replacing your whirlpool for final installation, be certain that an opening has been provided in
the sub-floor for the drain. See the roughing-in drawing and Table 1 for suggested opening
size (shadowed) and location dimensions. The drain/overflow of the bath extends below the
bottom of the bath. Note that this requires a cutout in the floor.
The floor structure beneath the bath must be able to support a total weight of bath, water, and
bather. Refer to Table 1 under total weight for your model.
!
For Models: 2425L/V-LHO and 2425L/V-RHO, 2732L;
This bath must be supported along its entire bottom. Use mortar as bedding
material (do not use sand or foam). Apply enough mortar to support the complete
bottom of the bath. After the mortar has been poured, and before it sets, position
whirlpool or bath within recess until the rim is leveled against the leveling stringers (see
"Typical Recess Installation") shown below.
C
The rim of the bath must not support weight. Allow the mortar material to completely
harden before applying weight to the rim or bottom of the bath. Any finish material such
!
TILE
as tile or wall board must be self-supporting if it contacts the deck of the bath.
WALLBOARD
SEALANT
BATH
TILE
BEAD
STRIP
For Models: 2645L/V, 2771L/V, 2773L/V, 2774L/V, 2775L/V, 2422L/V,
2711L/V, 2908L/V, 6060L/V and 7236L/V;
ADHESIVE
Replace whirlpool and re-shim the integral support feet, shimming the entire length of the
support feet. Secure the shims using construction adhesive, silicone, mortar or
equivalent materials. While not a necessity, the use of a foundation base consisting of
cement, mortar, or grout will help provide a solid and secure installation.
LEVELING STRINGER
1 x 4 (not for support)
The rim of the bath must not support weight. If foundation base is used, allow the
!
NOTE: Tile bead kit not included and
bedding material to completely harden before applying weight to the rim or bottom of
the bath. Any finish material such as tile or wall board must be self-supporting if it
contacts the deck of the bath.
must be purchased separately.
TYPICAL PIER TYPE INSTALLATION
TYPICAL RECESS INSTALLATION
AS DESIRED
F
CUTOUT
G
CUTOUT
C
C
12
(305 mm)
12
(305 mm)
AS DESIRED
E
MOUNTING
SURFACE
LEVELING
STRINGERS
NOTE:
24
(610 mm)
FRONT EDGE
WATERPROOF
SEALANT
24
(610 mm)
OF BATH MUST
BE SUPPORTED
BY STUD WALL OR
AMERICAN STANDARD
APRON KIT
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
BATH
ALLOW OPEN FRAMING ON
PUMP/MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
ALLOW OPEN FRAMING ON PUMP/MOTOR
END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
(EXCEPT 2425 WHERE APRON IS PRIMARY ACCESS OPENING)
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
FOR E & D DIMENSIONS SEE TABLE 1 ON PAGE 5.
FOR G & F DIMENSIONS SEE TABLE 1 ON PAGE 5.
753737-100 Rev. E
10
Download from Www.Somanuals.com. All Manuals Search And Download.
TYPICAL FLANGE MOUNTING DETAIL
SUGGESTED WHIRLPOOL / BATH
INSTALLATION METHOD
TYPICAL INSTALLATION -
CORNER
WOOD
STUDS
STUD
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
ROOFING NAIL
SEALANT
TUB
19-1/2
(495mm)
1 x 3 (25 x 76mm) WOOD
STRINGER FULL LENGTH
STEEL
STUDS
STEEL
STUD
WHIRLPOOL
ACCESS PANEL
WASHER
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
SEALANT
* SEE CUTOUT
TEMPLATE PROVIDED
4" (102mm)
DRYWALL
SCREW
TUB
1 x 3 (25 x 76mm) WOOD
STRINGER FULL LENGTH
UNLESS AN ACCESS OPENING OF AT LEAST
12" x 24" (305 x 610mm) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
SECURE THE BATH TO THE STUDS AS SHOWN
FOR WOOD OR STEEL STUD CONSTRUCTION.
UNDER DECK MOUNTING INSTRUCTIONS
Please note that care must be taken to protect the surface of the tub during all aspects of the installation.
Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result.
1. Install the tub per the installation instructions provided with the unit.
2. Prepare the bath deck support structure per the local codes. Note - the bath deck must be self supporting.
3. Cut bath deck to your specifications.
4. Place the bath deck in position and trace the opening on the tub with a soft pencil. Do not drill or cut the bath
deck with the tub directly beneath it as damage to the tub may result.
5. Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line.
6. Replace the bath deck and secure it into place.
7. Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal.
8. Remove excess sealant per the manufacturer's instructions.
Finished bath deck surface material must be
self-supporting and secured per local codes
Waterproof
Bath deck support material
Sealant
Bathtub
Tub support structure per installation
instructions provided with the tub
753737-100 Rev. E
11
Download from Www.Somanuals.com. All Manuals Search And Download.
WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Permit access for servicing motor as noted.
!
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS:
GFCI CIRCUIT REQUIREMENTS:
FOR MODEL NUMBERS:
The whirlpool should be installed on a 120 vac, 15 amp dedicated
GFCI circuit.
2422, 2425, 2645, 2732
2771, 2908
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
ALL MODELS
Optional heater requires a separate 15 amp maximum GFCI circuit.
The whirlpool should be installed on a 120 vac, 20 amp dedicated
GFCI circuit.
6060, 2775, 2773, 2711,
2774, 7236
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
ALL MODELS
Optional heater requires a separate 15 amp maximum GFCI circuit.
120 VAC
PUMP/MOTOR
GND.
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
WIRE SELECTION GUIDE
Maximum distance from
fusebox to motor
The sizes shown on this
chart are recommendations
for copper conductors
only. Always follow
local and national
Wire Length
50'
12
100'
150'
200'
115V Power Line
electrical codes
Wire Size (AWG)
10
8
8
753737-100 Rev. E
12
Download from Www.Somanuals.com. All Manuals Search And Download.
For 6060L/V Corner Only
OPERATION
Fig. 1
WARNING: Prior to operation, review the Important Safety Instructions
listed at the beginning of this instruction manual.
Once the heater is installed and the whirlpool pump is operating, the heater is
totally automatic. The heater will help maintain the temperature of the water in
the bath.
WHIRLPOOL
HEATER
L™
E-Z INSTAL
HEATER “ON” LIGHT
Pressure Switch
FACTORY INSTALLED - NOT FOR RESALE
HEATER P/N: 753174-100
The heater is equipped with a preset pressure switch. The pump must be
running with water flowing in the whirlpool to allow the heater to turn on.
Bonding Lug on
Heater Housing
Indicator Light
This light turns on whenever the heater is operating.
High-Limit Switch
The heater includes an exclusive "Intelligent High-Limit". This safety circuit will not "false trip" from hot tap water. It will only turn the heater
off if the thermostat fails. If the high-limit trips frequently, call a service technician.
To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply (1) Turn off the whirlpool pump. (2) Drain
water from the tub. (3) Remove power from heater by unplugging at receptacle or turning off circuit breaker. (4) The heater circuit will
automatically reset in less than 15 minutes. (5) Restore power to the heater. (6) Whirlpool bath is now ready to use.
ELECTRICAL CONNECTIONS
Install a separate 120VAC / 15AMP dedicated circuit with GFCI (Ground Fault Circuit Interrupter) protection.
At initial start-up with power ON, push the GFCI test button. The reset button should pop out. Push this button in to reset. If the GFCI fails to
operate in this manner, there is a ground fault or malfunction, indicating the possibility of electrical shock. Turn off the power and do not
use the bath until the source of the problem has been identified and corrected.
1. Route two separate branch circuits to the junction box near the whirlpool as shown in Figure 2. Each branch circuit MUST BE GFCI
PROTECTED and must use copper conductors only.
2. Ensure the heater and pump are properly GROUNDED and BONDED as required. Attach the 8 AWG solid copper conductor supplied with
the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3. The conductor is secured to the lugs using set
screws. The motor frame shall have a second 8 AWG solid copper conductor connected from the frame bonding lug to the homes electrical
panel or approved local bonding point as shown in Figure 3.
SEPARATE
15 AMP GFCI OUTLET
Fig. 2
Fig. 3
ELECTRICAL INSTALLATION
120 VAC
(HEATER)
(PUMP/MOTOR)
GND.
HEATER
RUN 8 AWG SOLID COPPER
CONDUCTORS FROM
HEATER BONDING LUG TO
PUMP/MOTOR FRAME LUG
AND FROM PUMP/MOTOR
LUG TO APPROVED
SEPARATE 15 AMP GFCI OUTLET
SEPARATE 20 AMP GFCI OUTLET
(for 2.1 H.P.R. PUMP ONLY)
GROUND AS SHOWN
120 VAC
FIRST COPPER
CONDUCTOR
SECOND
COPPER
CONDUCTOR
PUMP/MOTOR FRAME WITH
BONDING LUGS
TO GROUND
PUMP/MOTOR
GND.
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
753737-100 Rev. E
13
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION:
NOTE: Each whirlpool is shipped from the factory with an air actuator on/off switch and pump with attached
power supply cord. OPERATING THE SYSTEM WITHOUT WATER (DRY RUNNING) WILL CAUSE PUMP
DAMAGE AND VOID THE WARRANTY. Always fill the whirlpool before operating the pump. The air switch is
mounted either on the deck or side wall of the tub.
1.
Fill the Whirlpool: Water level must be at least one inch (25mm) above the highest jet for proper operation.
(See diagram below.)
Do not fill whirlpool more than 2/3 full prior to the user completely immersing themselves into unit.
2.
3.
Start Whirlpool: Push on center of button. Button will depress and whirlpool will start.
Stop Whirlpool: Depress and release button and whirlpool will stop.
SAFE-T-HEATER
REMOVABLE BLANK
*
AIR TUBING
AIR ACTUATOR SWITCH
(location varies with model)
WATER LEVEL
OUTLET MUST BE
GFCI PROTECTED
(all heaters require separate GFCI)
6060L/V includes factory installed heater
*
Air Volume Control Adjustments: Water turbulence is determined by the amount of air mixed with the
water. Rotate the air volume control counterclockwise for more turbulence--clockwise for less.
4.
Air Volume Control Adjustments:
MORE AIR
LESS AIR
753737-100 Rev. E
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjustable Flow Clean Jet™: The water flow action may be adjusted from vigorous to soft by rotating the nozzle
counterclockwise for vigorous and clockwise for soft.
NOTE: You may balance the air volume control and nozzle adjustment for the most desirable condition.
Large Jet
Small Jet
Softer Massage
Softer Massage
(counter-clockwise)
(counter-clockwise)
More Vigorous Massage
(clockwise)
More Vigorous Massage
(clockwise)
Lifetime™ Drain Model 1599 (required on Models 7236L/V, 2422L/V,
2425L/V, 2771L/V)
Overflow:
Partially fill tub, then enter tub before completely filling to prevent overflow.
Tip Toe Drain:
Depress drain cap to open or close drain.
Access Panel (Model 2425L/V)
Remove access panel to service motor.
Tip Toe Drain
Overflow
Access Panel
753737-100 Rev. E
15
Download from Www.Somanuals.com. All Manuals Search And Download.
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain assembly, connect whirlpool drain to waste line in accordance with the drain assembly instructions.
Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with
water to a point 2" above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking.
(Although the pump couplings are factory tightened and inspected, some loosening may have occurred during transit.) Make sure
the whirlpool is connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the
whirlpool is running.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use
wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains
®
may be removed using granular Spic and Span mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
AFTERCARE and CLEANING
• The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and
maintenance.
• Always fill the tub with temperate water. Excessively hot water may cause surface damage
• Remove bath mat after use and hang to dry. Allowing bath mat to dry in the tub may cause surface damage.
• Clean after use with a mild liquid household detergent cleaner. Do not use Lestoil, Lysol Disinfectant (spray or
concentrate), or Lysol Basin, Tub and Tile Cleaner, Windex, Mr. Clean, Dow Disinfectant Bathroom Cleaner, or
cleaning products in aerosol cans.
HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.
• Do not use wire brushes, knives or sharp objects to remove stains, cigarette tar deposits,or other surface blemishes.
• Abrasive cleaners or powders must not be used, since they will dull the surface. If the glossy surface looses
its sheen, dulled areas can be restored by rubbing with a white "automotive type" polishing compound and
waxing with a "liquid wax."
• Do not wax areas where you walk or stand.
• Do not allow nail polish remover, acetone, dry cleaning fluid, paint remover or other solvents to come into
contact with the surface.
• Clean the surrounding surface immediately after using caustic drain cleaners.
• Burning cigarettes will damage the surface.
• Should damage to the fixture occur, repairs can be made quickly and easily.
Your distributor or builder can provide details.
• Do not permit drain cleaner to enter the circulation system.
CIRCULATION SYSTEM CLEANING-PURGING PROCEDURES
STEP 1. Once every month purge and clean the circulating system. Fill whirlpool with warm water and add two teaspoons
of dishwasher detergent and one-half cup of house hold bleach.
STEP 2. Activate whirlpool system in accordance with operating instructions or two minutes.
STEP 3. Drain and refill whirlpool with cool water and circulate for additional five minutes.
STEP 4. Drain whirlpool completely.
753737-100 Rev. E
16
Download from Www.Somanuals.com. All Manuals Search And Download.
AS AMERICA, INC. (AMERICAN STANDARD) LIMITED LIFETIME WARRANTY
FOR LIFETIME™ / EVOLUTION™ ACRYLIC WHIRLPOOLS
AS America (“American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this whirlpool or any
of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long
as it is owned by the original consumer purchaser.
This warranty shall only become effective upon receipt by American Standard of a completely filled out Warranty Registration Card evidencing
proof of purchase.
THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY MANNER CONTRARY TO THE
INSTALLATION INSTRUCTIONS. In no event will American Standard be liable for the cost of repair or replacement of any installation
materials including but not limited to tiles, marble etc.
This limited warranty DOES NOT COVER the following:
1. Defects or damages arising from shipping, installation, alterations, accidents, abuse, misuse, lack of proper maintenance and cleaning as
directed in the owner’s manual and use of other than genuine American Standard replacement parts, in all cases whether caused by a
plumbing contractor, service company, the owner or any other person.
2. Deterioration through normal wear and tear and the expense of normal maintenance.
3. Commercial application.
4. Options and accessories. American Standard’s limited warranty on these items is one year for parts only and excludes labor. This one
year limited warranty covers accessories manufactured by American Standard (e.g. aprons, drains, grab bars, heaters, trim kits) against
defects of material or workmanship. Warranty coverage begins on the date the accessory was originally purchased by the owner.
5. Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor or other costs incurred in
connection with product removal or installation under this limited warranty.
6. ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED, OR
THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES, INCLUDING THOSE OF
MERCHANTABILITY OR FITNESS FOR AN INTENDED PURPOSE. (Some jurisdictions do not allow limitations on how long an implied
warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these limitations and exclusions may not apply to you.)
7. Responsibility for compliance with local code requirements. (Since local code requirements vary greatly distributors, retailers, dealers,
installation contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a
specific product.)
This warranty gives you specific legal rights. You may have other legal rights that vary from state to state. For service under this warranty, you
should contact the following:
By Telephone:
1-800-442-1902
By Mail: American Standard Inc.
P.O. Box 6820
Piscataway, N.J. 08855
Attention: Customer Care Center
AS AMERICA, INC. (AMERICAN STANDARD) ONEYEAR LIMITED WARRANTY
FOR E-Z INSTALL WHIRLPOOL HEATER
If inspection of this AS American, Inc. (“American Standard”) plumbing product, within one year after its initial purchase, confirms that it is
defective in materials or workmanship, American Standard will repair or, at its option, exchange the product for a similar model.
This warranty applies only to the original purchaser and installation of these products.
This limited warranty does not apply to local building code compliance. Since local building codes vary considerably, the purchaser of this
product should check with a local building or plumbing contractor to insure local code compliance before installation.
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance,
abuse, misuse, accident or other damages; if it was not installed in accordance with American Standard's instructions; or if it has been
modified in a manner inconsistent with the product as shipped by American Standard.
American Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or
installation, nor shall American Standard be responsible for any other incidental or consequential damages attributable to a product
defect or to the repair or exchange of a defective product, all of which are expressly excluded from this warranty. (Some states or
provinces do not allow the exclusion or limitation of implied warranties, so this exclusion may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in
which case this warranty does not affect such statutory rights.
For service under these warranties, it is suggested that a claim be made through the contractor or dealer from or through whom the product
was purchased, or that a service request (including a description of the product model and of the defect) be sent to:
By Telephone:
1-800-442-1902
By Mail: American Standard Inc.
P.O. Box 6820
Piscataway, N.J. 08855
Attention: Customer Care Center
SERVICE: For service or repair contact the number below.The model number and
serial number for your whirlpool are located on a label near the motor.
HOTLINE FOR HELP
For toll-free information and answers to your questions, call 1 (800) 442-1902
weekdays: 8:00 a.m. to 5:00 p.m. Eastern Time
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2008
753737-100 Rev. E
17
Download from Www.Somanuals.com. All Manuals Search And Download.
|