American Standard Hot Tub 0163060 User Manual

SOLAR™  
BATH  
ENAMELED STEEL  
BARRIER FREE  
SOLAR BATH™ FOR ABOVE FLOOR  
ROUGH INSTALLATION  
0163.060 Right hand outlet  
0165.060 Left hand outlet  
Product Features:  
• Acid resisting, enameled steel construction  
• One-piece bath  
• Integral apron  
• For above-floor rough installations  
• End drain outlet  
• Full slip-resistant pattern  
• Straight tiling flange  
• Fully-bonded support pad  
Nominal Dimensions:  
1524 x 762 x 445mm  
(60" x 30" x 17-1/2")  
OPTIONAL TO FINISHED TO FINISHED  
FLOOR (USALLY BETWEEN 1651 to  
1981mm ( 65" & 78')  
NOTE: NO CONCEALED  
PIPING FURNISHED  
1/2 S.P.S. OR 1/2"  
C.W.T. SUPPLIES  
76mm  
Bathing Well Dimensions:  
1346 x 610 x 337mm  
(53" x 24" x 13-1/4")  
SHOWER 1/2" S.P.S.  
711mm  
(28)  
203mm  
(8)  
(3)  
19mm  
(3/4)  
FINISHED  
WALL  
Compliance Certifications -  
197mm  
(7-3/4)  
Meets or Exceeds the Following Specifications:  
• ASME A112.19.4 for Enameled Steel Plumbing  
Fixtures  
C/L OF DRAIN  
C/L OF SHOWER CURTAIN ROD  
(USUALLY 1930mm (76")  
FROM FIN. FLOOR)  
FINISHED  
WALL  
C/L OF VALVES  
102mm  
1524mm  
(60)  
• ASTM F-462 for Slip-resistant Bathing Facilities  
(44mm [1-3/4"]  
(8)  
DIA. HOLES)  
102  
(4)  
365mm  
(14-3/8)  
SPOUT  
1/2" S.P.S.  
305mm  
(12)  
102 (4)  
To Be Specified:  
Color:  
Bath Faucet*:  
Faucet Finish:  
Drain: 1583.470  
FINISHED  
WALL  
445mm  
(17-1/2)  
ROUGH  
FLOOR  
19mm  
(3/4)  
762mm  
(30)  
DRAIN SHOE  
95mm  
4
PLUMBER NOTE:  
PROVIDE SUITABLE FULL LENGTH  
SUPPORT AT THIS POINT.  
SUMP PAD  
* See faucet section for additional models available  
NOTES:  
0165.060 LEFT HAND OUTLET (SHOWN).  
0163.060 RIGHT HAND OUTLET (REVERSE DIMENSIONS).  
SHOWN WITH POP-UP C.D. & O.  
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.  
CONCEALED PIPING NOT INCLUDED.  
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range  
of tolerances established by ANSI Standard A112.19.4. These measurements  
are subject to change or cancellation. No responsibility is assumed for use of  
superseded or voided leaflet.  
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES  
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND  
USEABLE BUILDING FACILITIES-CHECK LOCAL CODES.  
INSTALL WITH SEAT AT HEAD END.  
H161  
© 2008 AS America Inc.  
Revised 2/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Agilent Technologies Network Router 87075C User Manual
Agilent Technologies TV Converter Box 5954 2664 User Manual
Alcatel Lucent Network Card 7549 MGW User Manual
AllerAir Air Cleaner Air Rhino 2000 User Manual
Alpine Car Stereo System CHM S655 User Manual
AO Smith Water Heater ACGSS00305 User Manual
Audiovox Car Stereo System CD2610 User Manual
Audiovox Remote Starter PRO 9171FT User Manual
Avet Reels Fishing Equipment JX 6 3 User Manual
Avital Automobile Alarm 834002 User Manual