THANK YOU...
for selecting an American Standard bath.Your new bath is shipped to you after careful inspection. The whirlpool
and air bath versions are completely assembled with pump/blower and system piping. All you need to finish the
installation are your selected fittings and electrical connections.
To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.
For questions or service issues, please call Technical Support 1-(800)-442-1902.
Please do not contact or return product to the store.
© AS America, Inc. 2010
All product names listed herein are trademarks of AS America, Inc. unless otherwise noted.
754532-100 Rev. A
1
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS!
!
WARNING: Risk of personal injury. Do not permit children to use this bathtub without adult supervision. Never drop or
insert any object into any opening. Do not operate this unit without the guard over the suction fitting.
!
!
WARNING: Risk of electric shock. Do not permit electrical appliances near any bathtub when bathtub contains water.
WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse medical
history should consult a physician before using this product.
!
!
!
WARNING: Risk of personal injury. Do not overfill bathtub before entering. Entering tub when filled more than 2/3 can
cause overflow and slippery conditions. Exercise caution when entering and exiting.
WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not recommended. Avoid
alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of
consciousness or even drowning.
WARNING: Pregnancy. If you are or think you may be pregnant, consult your physician before using the bathtub.
Use this unit only for its intended use as described in this manual.
Do not use any attachments not recommended by American Standard.
The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter (GFCI). Such a
GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The
GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the
GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current is flowing,
indicating the possibility of an electric shock. Do not use this air bath. Disconnect the air bath and have the problem corrected by a
licensed electrician before using.
SAVE THESE INSTRUCTIONS
754532-100 Rev. A
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Framing Instructions
Each bath arrives ready for installation, completely equipped with the pump/blower electronics
and plumbing necessary for operation. However, a drain/overflow kit is required for each bath
and it is not included.
The variety of installations for this bath may require framing procedures other than those shown.
Locate studs as required. Ensure roughing-in dimensions are proper, plumb, and square.
!
Remove the bath from the carton. Retain the shipping carton until satisfactory
inspection of the product has been made. Do not lift the bath by the plumbing at
any time; handle by the shell only.
!
All bath units are factory tested for proper operation and watertight connections
prior to shipping. Prior to installation, the bath must be filled with water and
operated to check for leaks that may have resulted from shipping damage or
mishandling.
!
The sumps of these baths are supported by feet and no additional sump
support is required. Once the bath is in place, the feet should be shimmed and
secured accordingly so that the rim of the bath contacts the stringer or pier but
supports no weight.
Provisions must be made in all installations for an access opening for servicing the
bath pump/blower. Unless an access opening of at least 12" x 24" (305mm x 610mm)
is provided, warranty service will not be performed. It is strongly recommended that an
additional opening be provided for access to drain components.
!
!
Each bath has a nominal length (L), width (W), and Height (H) along with a rim
height. Unless otherwise noted in the following rough-in references, assume
that the nominal tolerances are as much as +/-1/4 inch (6mm). Therefore, it is
strongly recommended that the installer build the surrounding structure after
receiving the actual bath. Structural measurements should be verified against
the actual bath received to ensure proper fit.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden
popsicle stick or tongue depressor.
Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid
dishwashing detergent.
Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
754532-100 Rev. A
4
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES FOR RECESS TYPE INSTALLATIONS
C
12"
(305 mm)
E
LEVELING
NOTE:
STRINGERS
24"
FRONT EDGE
(610 mm)
OF BATH MUST
BE SUPPORTED
BY STUD WALL OR
ACCESS PANEL MUST BE LOCATED
AMERICAN STANDARD
ON THE SAME SIDE AS THE MOTOR.
APRON KIT
ALLOW OPEN FRAMING ON
PUMP/MOTOR END FOR SERVICE.
ACCESS PANELS NOT
REQUIRED FOR BATH TUBS
UNLESS AN ACCESS OPENING OF AT LEAST 12" x 24" (305 x 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
TYPICAL TILE BEAD INSTALLATION
TYPICAL TILE FLANGE INSTALLATION
WOOD
STUDS
STUD
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
TILE
ROOFING NAIL
SEALANT
WALLBOARD
SEALANT
TUB
TILE
BEAD
STRIP
BATH
1" x 3" (25 x 76mm) WOOD
STRINGER FULL LENGTH
ADHESIVE
STEEL
STUDS
STEEL
STUD
WASHER
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
LEVELING STRINGER
1" x 4" (25mm x 102mm) not for support
SEALANT
4" (102mm)
DRYWALL
SCREW
NOTE: Tile bead kit not included and must
TUB
be purchased separately.
1" x 3" (25 x 76mm) WOOD
STRINGER FULL LENGTH
SECURE THE BATH TO THE STUDS AS SHOWN
FOR WOOD OR STEEL STUD CONSTRUCTION.
754532-100 Rev. A
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES FOR PIER TYPE INSTALLATIONS
AS DESIRED
F
CUTOUT
G
CUTOUT
C
12"
(305 mm)
AS DESIRED
MOUNTING
SURFACE
WATERPROOF
SEALANT
24"
(610 mm)
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
BATH
ALLOW OPEN FRAMING ON
PUMP/MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
UNDER DECK MOUNTING INSTRUCTIONS
Please note that care must be taken to protect the surface of the tub during all aspects of the installation.
Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result.
1. Install the tub per the installation instructions provided with the unit.
2. Prepare the bath deck support structure per the local codes. Note - the bath deck must be self supporting.
3. Cut bath deck to your specifications.
4. Place the bath deck in position and trace the opening on the tub with a soft pencil. Do not drill or cut the bath
deck with the tub directly beneath it as damage to the tub may result.
5. Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line.
6. Replace the bath deck and secure it into place.
7. Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal.
8. Remove excess sealant per the manufacturer's instructions.
Finished bath deck surface material must be
self-supporting and secured per local codes
Waterproof
Bath deck support material
Sealant
Bathtub
Tub support structure per installation
instructions provided with the tub
754532-100 Rev. A
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR WHIRLPOOLS AND BATH TUBS
Description
Dimensions
L-W-H
Drain /
Height to
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product Gallon to Whirlpool
Overflow Underside
of Deck: C
Weight
Overflow Operating
Volume
2664
Scala
Corner
L 83-1/2" (2121mm)
W 63-3/4" (1619mm)
H 19-3/4" (502mm)
A 16"
C 18-1/4"
(406mm) (464mm)
B 13-1/4"
Template
Provided
N/A
6-3/8"
(162mm)
781 lb. (351 kg)/
37 lb./sq.ft.
(182 kg/sq.m)
94 lb.
(43 kg.)
80 gal.
(303 l.)
58 gal.
(220 l.)
(337mm)
2709
L
69-1/4" (1759mm)
A 15"
C 18-1/4"
(381mm) (464mm)
B 9-7/8"
Template
Provided
As
Desired
3"
(76mm)
640 lb. (291 kg)/ 107 lb.
64 gal.
(242 l.)
53 gal.
(200 l.)
Ellisse Oval W 38-1/2" (978mm)
35 lb./sq.ft.
(49 kg.)
6'
H 19-3/4" (502mm)
(171 kg/sq.m)
(251mm)
2711
Ellisse
6' x 48"
L
72" (1829mm)
A 16-5/8" C 19-1/2"
(422mm) (495mm)
B 12"
70-1/2"
72-3/16"
4"
950 lb. (431 kg)/ 133 lb.
95 gal.
(359 l.)
74 gal.
(280 l.)
W 48" (1219mm)
H 21-1/2" (546mm)
40 lb./sq.ft.
(60 kg.)
(1791mm)
x 46-1/2"
(1181mm)
(1833mm)
x 46-1/2"
(1181mm)
(102mm)
(196 kg/sq.m)
(305mm)
2742
Town Square
6' x 42"
A 16-1/4" C 20"
(413mm) (508mm)
B 13-1/4"
70"
71-11/16"
(1821mm)
x 40-1/4"
(1022mm)
4"
690 lb. (313 kg)/ 115 lb.
69 gal.
60 gal.
(227 l.)
L
71-1/2" (1816mm)
(1778mm)
x 40-1/4"
(1022mm)
(102mm)
33 lb./sq.ft.
(52 kg.) (261 l.)
W 41-3/4" (1060mm)
H 22" (559mm)
(161 kg/sq.m)
(337mm)
2748
Town Square
5' x 42"
A 14-1/2" C 21"
(368mm) (533mm)
B 14-1/2"
58"
59-11/16"
(1517mm)
x 40-1/8"
(1019mm)
5-1/4"
(133mm)
611 lb. (277 kg)/ 110 lb.
60 gal.
55 gal.
(208 l.)
L
59-1/2" (1511mm)
(1473mm)
x 40-1/8"
(1019mm)
40 lb./sq.ft.
(50 kg.) (227 l.)
W 41-5/8" (1057mm)
H 23" (584mm)
(196 kg/sq.m)
(368mm)
2806
Heritage Oval
6' x 36"
L
72" (1829mm)
A 17"
C 19-1/2"
(432mm) (495mm)
B 11"
Template
Provided
As
Desired
5-1/2"
(140mm)
744 lb. (338 kg)/ 135 lb.
73 gal.
44 gal.
(166 l.)
41 lb./sq.ft.
(61 kg.) (276 l.)
W 35-3/4" (908mm)
H 21-1/2" (546mm)
(200 kg/sq.m)
(279mm)
2903
Savona Oval
5' x 42"
L
60" (1524mm)
W 42-1/4" (1073mm) (432mm) (489mm)
A 17"
C 19-1/4"
Template
Provided
3"
(76mm)
640 lb. (291 kg)/ 107 lb.
64 gal.
53 gal.
(200 l.)
As
Desired
35 lb./sq.ft.
(171 kg/sq.m)
(49 kg.) (242 l.)
H 21-1/4" (540mm)
B 9-1/2"
(241mm)
As
Desired
95 lb.
(43 kg.)
2908
Reminiscence
Oval
L
66" (1676mm)
A 17"
(432mm)
B 13"
C 18-1/4"
(464mm)
Template
Provided
6"
659 lb. (299 kg)/
40 lb./sq.ft.
(191 kg/sq.m)
68 gal.
(257 l.)
55 gal.
(208 l.)
W 36" (914mm)
H 24-1/4" (616mm)
(152mm)
(330mm)
108 lb.
(49 kg.)
5-5/8"
(130mm)
824 lb. (374 kg)/
25 lb./sq.ft.
(117 kg/sq.m)
86 gal.
(352 l.)
71 gal.
(269 l.)
N/A
6060
Cadenza
Corner
L
76-3/4" (1949mm)
A 17"
C 19-1/2"
(495mm)
Template
Provided
751680-100
W 65-3/8" (1661mm)
H 21-1/2" (546mm)
(432mm)
B 13-3/4"
(349mm)
101 lb.
(45 kg.)
7236
Virtuoso
6' x 36"
L
72" (1829mm)
A 17-3/4"
(451mm)
B 11"
C 19-1/4"
(489mm)
70-1/2"
72-3/16"
(1833mm)
x 34-1/2"
(876mm)
4"
751 lb. (338 kg)/
42 lb./sq.ft.
(204 kg/sq.m)
78 gal.
(296 l.)
69 gal.
(262 l.)
W 36" (914mm)
H 21-1/4" (540mm)
(1791mm)
x 34-1/2"
(876mm)
(102mm)
(279mm)
TABLE 1
754532-100 Rev. A
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 2664
1" (25mm)
INTEGRAL TILE
FLANGE (2) SIDES
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
10" x 10"
(254mm x 254mm)
DRAIN OUTLET
CUTOUT
21-3/4"
(552mm)
8-1/2"
(216mm)
3/4"(19mm)
CUTOUT DIMENSION
16"
(406mm)
C
L
OF DRAIN OUTLET
41"
(1041mm)
MODEL SERIES 2709
69-1/4"
(1759mm)
9-7/16"
(240mm)
OUTLINE OF
CUTOUT
12" (305mm) x 9" (229mm)
CUTOUT IN FLOOR FOR DRAIN
38-1/2"
(978mm)
19-1/4"
(489mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
3"
(76mm)
COF DRAIN
L
OUTLET
754532-100 Rev. A
8
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 2711
72"
(1829mm)
OUTLINE OF CUTOUT
4"
36-1/2"
(927mm)
70-1/2" X 46-1/2"
(1791 X 1181mm)
(102mm)
12"
(305mm)
C/L OF
DRAIN
9" x 14"
(229 x 356mm)
FLOOR
CUTOUT
48"
(1219mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
GRAB BAR
FITTING AREA
OPTIONAL
DECK FITTING
AREA
RECOMMENDED
FITTING
LOCATION
2-1/2" X 11"
MODEL SERIES 2908
66"
(1676mm)
13"
(330mm)
18"
(457mm)
9" X 12"
(229 x 305mm)
FLOOR
CUTOUT
36"
(914mm)
2-1/2" REF.
(64mm)
INTEGRAL
FITTING
DECK
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
6"
OVERFLOW
OUTLINE OF
CUTOUT
(152mm)
C/L OF
DRAIN
OUTLET
754532-100 Rev. A
9
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 2806
72"
(1829mm)
11"
(279mm)
18"
(457mm)
9" x 13"
(229 x 330mm)
FLOOR CUTOUT
35-3/4"
(908mm)
INTEGRAL
FITTING
DECK
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
5-1/2"
(140mm)
C/L OF DRAIN
OVERFLOW
OUTLINE
OF CUTOUT
MODEL SERIES 2903
60"
(1524mm)
9-1/2"
(241mm)
OUTLINE OF
CUTOUT - USE
TEMPLATE
4-1/4"
(1073mm)
12" (305mm) X 9"(229mm)
CUTOUT IN FLOOR FOR DRAIN
21-1/8"
(537mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
3"
(76mm)
C
OF DRAIN
OUTLET
L
754532-100 Rev. A
10
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 2742
71-1/2"
(1816mm)
4"
(102mm)
INTEGRAL
35-3/4"
FITTING DECK
3" x 14"
(76 x 356mm)
3"
(76mm)
(908mm)
13-1/4"
(337mm)
C/L OF DRAIN OUTLET
EDGE
OF FLOOR
CUTOUT
41-3/4"
(1060mm)
FLOOR CUTOUT
5" X 15"
(127 X 381mm)
26-3/4"
(679mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
3/4"
(19mm)
ALL INSTALLATIONS
OUTLINE OF CUTOUT
70" X 40-1/4"
(1778 X 1022mm)
MODEL SERIES 2748
59-1/2"
(1511mm)
INTEGRAL
FITTING DECK
3" X 14"
3"
(76mm)
29-7/8"
(759mm)
5-1/4"
(133mm)
(76 X 356mm)
14-1/2"
(368mm)
C/L OF
DRAIN
OUTLET
FLOOR CUTOUT
5" X 12"
(127 X 305mm)
EDGE OF
FLOOR
CUTOUT
41-5/8"
(1057mm)
3/4"
(19mm)
OUTLINE OF CUTOUT
58-1/4" X 40-1/4"
(1480 X 1022mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
754532-100 Rev. A
11
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 6060
76-3/4" REF.
(1949mm)
38-3/8"
(975mm)
C/L
OUTLINE OF
CUTOUT
SEAT AREA
65-3/8"
(1661mm)
7" x 15" CUTOUT
(178mm x 381mm)
PROVIDE ACCESS TO PUMP
FOR SERVICE ON ALL INSTALLATIONS
NOTE: APRON ASSEMBLY WILL
PROVIDE REQUIRED
ACCESS FOR SERVICING
13-5/8"
(346mm)
C/L OF
DRAIN
5-5/8"
(143mm)
RECOMMENDED FITTING LOCATION
2-1/2" x 15" (64 x 381mm)
10"
(254mm)
4-1/2"
(114mm)
USE CUTOUT TEMPLATE SUPPLIED WITH PACKAGED PRODUCT.
MODEL SERIES 7236
72"
(1829mm)
36"
(914mm)
3/4"
(19mm)
TYP.
OUTLINE OF CUTOUT
70-1/2" x 34-1/2"
(1791mm X 876mm)
36"
(914mm)
7 x 14 CUTOUT
(178 x 356mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
C/L OF DRAIN
4"
18-1/2"
(470mm)
(102mm)
11"
(279mm)
RECOMMENDED
FITTING LOCATION
2-1/2" x 11" (64 x 279mm)
754532-100 Rev. A
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR STUDIO 5' X 32" WHIRLPOOLS AND BATH TUBS
Description
Deck
Trim
Option
Dimensions
L-W-H
Drain /
Overflow
Height to
Underside
of Deck: C
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product Gallon to Whirlpool
Weight
Overflow Operating
Volume
A 17-3/4"
(451mm)
B 10-3/4"
(273mm)
C 21-7/8"
(556mm)
58"
(1473mm)
x 30"
59-11/16"
(1516mm)
x 30"
581 lb. (264 kg)/
44 lb./sq.ft.
(213 kg/sq.m)
90 lb.
(198 kg.)
59 gal.
(224 l.)
54 gal.
(205 l.)
2932
Studio
5' x 32"
Zero
(5/8")
L 59-1/2" (1511mm)
W 31-1/2" (800mm)
H 22-1/2" (572mm)
(762mm)
(762mm)
A 17-3/4"
(451mm)
B 10-7/8"
(276mm)
C 20-1/2"
(521mm)
58-1/4"
59-15/16"
(1522mm)
x 30-1/4"
(768mm)
581 lb. (264 kg)/
44 lb./sq.ft.
(213 kg/sq.m)
90 lb.
(198 kg.)
59 gal.
(224 l.)
54 gal.
(205 l.)
2932
Studio
5' x 32"
2"
L 59-3/4" (1518mm)
W 31-3/4" (806mm)
H 22-1/2" (572mm)
(1480mm)
x 30-1/4"
(768mm)
A 17-3/4"
(451mm)
B 11"
18-1/2"
(470mm)
58-1/2"
60-3/16"
(1529mm)
x 30-1/2"
(775mm)
581 lb. (264 kg)/
44 lb./sq.ft.
(213 kg/sq.m)
90 lb.
(198 kg.)
59 gal.
(224 l.)
54 gal.
(205 l.)
2932
Studio
5' x 32"
4"
L 60" (1524mm)
W 32" (813mm)
H 22-1/2" (572mm)
(1486mm)
x 30-1/2"
(775mm)
(279mm)
A 17-3/4"
(451mm)
B 11"
C 20-1/2"
(521mm)
N/A
60-3/16"
(1529mm)
x 30-3/8"
(772mm)
581 lb. (264 kg)/
44 lb./sq.ft.
(213 kg/sq.m)
90 lb.
(198 kg.)
59 gal.
(224 l.)
54 gal.
(205 l.)
2933
Studio
5' x 32"
N/A
L 60" (1524mm)
W 31-7/8" (810mm)
H 22-1/2" (572mm)
(279mm)
w/Tile Flange
TABLE 2
ROUGH-IN REFERENCES
MODEL SERIES 2932 & 2933
60" NOMINAL
(1524mm)
OVERFLOW
C/L DRAIN
32" NOMINAL
(813mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
9" x 15"
(229 x 305mm)
DRAIN ASS’Y
ALL INSTALLATIONS
FLOOR CUTOUT
OUTLINE OF
CUTOUT
754532-100 Rev. A
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR STUDIO 5' X 36" WHIRLPOOLS AND BATH TUBS
Description
Deck
Trim
Option
Dimensions
L-W-H
Drain /
Overflow
Height to
Underside
of Deck: C
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product Gallon to Whirlpool
Weight
Overflow Operating
Volume
A 17-3/4"
(451mm)
B 10-3/4"
(273mm)
C 21-7/8"
(556mm)
58"
(1473mm)
x 34"
59-11/16"
(1516mm)
x 34"
686 lb. (311 kg)/
46 lb./sq.ft.
(223 kg/sq.m)
95 lb.
(209 kg.)
71 gal.
(269 l.)
64 gal.
(243 l.)
2934
Studio
5' x 36"
Zero
(5/8")
L 59-1/2" (1511mm)
W 35-1/2" (902mm)
H 22-1/2" (572mm)
(864mm)
(864mm)
A 17-3/4"
(451mm)
B 10-7/8"
(276mm)
C 20-1/2"
(521mm)
58-1/4"
59-15/16"
(1522mm)
x 34-1/4"
(870mm)
686 lb. (311 kg)/
46 lb./sq.ft.
(223 kg/sq.m)
95 lb.
(209 kg.)
71 gal.
(269 l.)
64 gal.
(243 l.)
2934
Studio
5' x 36"
2"
L 59-3/4" (1518mm)
W 35-3/4" (908mm)
H 22-1/2" (572mm)
(1480mm)
x 34-1/4"
(870mm)
A 17-3/4"
(451mm)
B 11"
18-1/2"
(470mm)
58-1/2"
60-3/16"
(1529mm)
x 34-1/2"
(876mm)
686 lb. (311 kg)/
46 lb./sq.ft.
(223 kg/sq.m)
95 lb.
(209 kg.)
71 gal.
(269 l.)
64 gal.
(243 l.)
2934
Studio
5' x 36"
4"
L 60" (1524mm)
W 36" (914mm)
H 22-1/2" (572mm)
(1486mm)
x 34-1/2"
(876mm)
(279mm)
A 17-3/4"
(451mm)
B 11"
C 20-1/2"
(521mm)
N/A
60-3/16"
(1529mm)
x 34-3/8"
(873mm)
686 lb. (311 kg)/
46 lb./sq.ft.
(223 kg/sq.m)
95 lb.
(209 kg.)
71 gal.
(269 l.)
64 gal.
(243 l.)
2935
Studio
5' x 36"
N/A
L 60" (1524mm)
W 35-7/8" (911mm)
H 22-1/2" (572mm)
(279mm)
w/Tile Flange
TABLE 3
ROUGH-IN REFERENCES
MODEL SERIES 2934 & 2935
60" NOMINAL
(1524mm)
OVERFLOW
C/L DRAIN
36" NOMINAL
(914mm)
9" x 15"
(229 x 305mm)
DRAIN ASS’Y
PROVIDE ACCESS
TO PUMP
SERVING ON
FLOOR CUTOUT
ALL INSTALLATIONS
OUTLINE OF
CUTOUT
754532-100 Rev. A
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR STUDIO 5-1/2' X 36" WHIRLPOOLS AND BATH TUBS
Description
Deck
Trim
Option
Dimensions
L-W-H
Drain /
Overflow
Height to
Underside
of Deck: C
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product Gallon to Whirlpool
Weight
Overflow Operating
Volume
A 17-3/4"
(451mm)
B 10-3/4"
(273mm)
C 21-7/8"
(556mm)
64"
(1626mm)
x 34"
65-11/16"
(1668mm)
x 34"
766 lb. (348 kg)/
46 lb./sq.ft.
(227 kg/sq.m)
100 lb.
(220 kg.)
80 gal.
(303 l.)
73 gal.
(277 l.)
2938
Studio
5-1/2' x 36"
Zero
(5/8")
L 65-1/2" (1664mm)
W 35-1/2" (902mm)
H 22-1/2" (572mm)
(864mm)
(864mm)
A 17-3/4"
(451mm)
B 10-7/8"
(276mm)
C 20-1/2"
(521mm)
64-1/4"
65-15/16"
(1675mm)
x 34-1/4"
(870mm)
766 lb. (348 kg)/
46 lb./sq.ft.
(227 kg/sq.m)
100 lb.
(220 kg.)
80 gal.
(303 l.)
73 gal.
(277 l.)
2938
Studio
5-1/2' x 36"
2"
L 65-3/4" (1670mm)
W 35-3/4" (908mm)
H 22-1/2" (572mm)
(1632mm)
x 34-1/4"
(870mm)
A 17-3/4"
(451mm)
B 11"
18-1/2"
(470mm)
64-1/2"
66-3/16"
(1681mm)
x 34-1/2"
(876mm)
766 lb. (348 kg)/
46 lb./sq.ft.
(227 kg/sq.m)
100 lb.
(220 kg.)
80 gal.
(303 l.)
73 gal.
(277 l.)
2938
Studio
5-1/2' x 36"
4"
L 66" (1676mm)
W 36" (914mm)
H 22-1/2" (572mm)
(1638mm)
x 34-1/2"
(876mm)
(279mm)
A 17-3/4"
(451mm)
B 11"
C 20-1/2"
(521mm)
N/A
66-3/16"
(1681mm)
x 34-3/8"
(873mm)
766 lb. (348 kg)/
46 lb./sq.ft.
(227 kg/sq.m)
100 lb.
(220 kg.)
80 gal.
(303 l.)
73 gal.
(277 l.)
2939
Studio
5-1/2' x 36"
w/Tile Flange
N/A
L 66" (1676mm)
W 35-7/8" (911mm)
H 22-1/2" (572mm)
(279mm)
TABLE 4
ROUGH-IN REFERENCES
MODEL SERIES 2938 & 2939
66" NOMINAL
(1524mm)
OVERFLOW
C/L DRAIN
36" NOMINAL
(914mm)
9" x 15"
(229 x 305mm)
DRAIN ASS’Y
PROVIDE ACCESS
TO PUMP
SERVING ON
FLOOR CUTOUT
ALL INSTALLATIONS
OUTLINE OF
CUTOUT
754532-100 Rev. A
15
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR STUDIO 6' X 36" WHIRLPOOLS AND BATH TUBS
Description
Deck
Trim
Option
Dimensions
L-W-H
Drain /
Overflow
Height to
Underside
of Deck: C
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product Gallon to Whirlpool
Weight
Overflow Operating
Volume
A 17-3/4"
(451mm)
B 10-3/4"
(273mm)
C 21-7/8"
(556mm)
70"
(1778mm)
x 34"
71-11/16"
(1821mm)
x 34"
846 lb. (384 kg)/
47 lb./sq.ft.
(230 kg/sq.m)
105 lb.
(231 kg.)
89 gal.
(337 l.)
81 gal.
(307 l.)
2940
Studio
6' x 36"
Zero
(5/8")
L 71-1/2" (1816mm)
W 35-1/2" (902mm)
H 22-1/2" (572mm)
(864mm)
(864mm)
A 17-3/4"
(451mm)
B 10-7/8"
(276mm)
C 20-1/2"
(521mm)
70-1/4"
71-15/16"
(1827mm)
x 34-1/4"
(870mm)
846 lb. (384 kg)/
47 lb./sq.ft.
(230 kg/sq.m)
105 lb.
(231 kg.)
89 gal.
(337 l.)
81 gal.
(307 l.)
2940
Studio
6' x 36"
2"
L 71-3/4" (1822mm)
W 35-3/4" (908mm)
H 22-1/2" (572mm)
(1784mm)
x 34-1/4"
(870mm)
A 17-3/4"
(451mm)
B 11"
18-1/2"
(470mm)
70-1/2"
72-3/16"
(1833mm)
x 34-1/2"
(876mm)
846 lb. (384 kg)/
47 lb./sq.ft.
(230 kg/sq.m)
105 lb.
(231 kg.)
89 gal.
(337 l.)
81 gal.
(307 l.)
2940
Studio
6' x 36"
4"
L 72" (1829mm)
W 36" (914mm)
H 22-1/2" (572mm)
(1791mm)
x 34-1/2"
(876mm)
(279mm)
A 17-3/4"
(451mm)
B 11"
C 20-1/2"
(521mm)
N/A
72-3/16"
(1833mm)
x 34-3/8"
(873mm)
846 lb. (384 kg)/
47 lb./sq.ft.
(230 kg/sq.m)
105 lb.
(231 kg.)
89 gal.
(337 l.)
81 gal.
(307 l.)
2941
Studio
6' x 36"
N/A
L 72" (1829mm)
W 35-7/8" (911mm)
H 22-1/2" (572mm)
(279mm)
w/Tile Flange
TABLE 5
ROUGH-IN REFERENCES
MODEL SERIES 2940 & 2941
72" NOMINAL
(1524mm)
OVERFLOW
C/L DRAIN
36" NOMINAL
(813mm)
9" x 15"
(229 x 305mm)
DRAIN ASS’Y
PROVIDE ACCESS
TO PUMP
SERVING ON
FLOOR CUTOUT
ALL INSTALLATIONS
OUTLINE OF
CUTOUT
754532-100 Rev. A
16
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR STUDIO 6' X 42" WHIRLPOOLS AND BATH TUBS
Description
Deck
Trim
Option
Dimensions
L-W-H
Drain /
Overflow
Height to
Underside
of Deck: C
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product Gallon to Whirlpool
Weight
Overflow Operating
Volume
A 17-3/4"
(451mm)
B 10-3/4"
(273mm)
C 21-7/8"
(556mm)
70"
(1778mm)
x 40"
943 lb. (428 kg)/
45 lb./sq.ft.
(219 kg/sq.m)
110 lb.
(242 kg.)
100 gal. 91 gal.
L 71-1/2" (1816mm)
W 41-1/2" (1054mm)
H 22-1/2" (572mm)
71-11/16"
(1821mm)
x 40"
2942
Studio
6' x 42"
Zero
(5/8")
(379 l.)
(345 l.)
(1016mm)
(1016mm)
A 17-3/4"
(451mm)
B 10-7/8"
(276mm)
C 20-1/2"
(521mm)
70-1/4"
71-15/16"
(1827mm)
x 40-1/4"
(1022mm)
943 lb. (428 kg)/
45 lb./sq.ft.
(219 kg/sq.m)
110 lb.
(242 kg.)
100 gal. 91 gal.
(379 l.) (345 l.)
2942
Studio
6' x 42"
2"
L 71-3/4" (1822mm)
W 41-3/4" (1060mm)
H 22-1/2" (572mm)
(1784mm)
x 40-1/4"
(1022mm)
A 17-3/4"
(451mm)
B 11"
18-1/2"
(470mm)
70-1/2"
72-3/16"
943 lb. (428 kg)/
45 lb./sq.ft.
(219 kg/sq.m)
110 lb.
(242 kg.)
100 gal. 91 gal.
(379 l.) (345 l.)
2942
Studio
6' x 42"
4"
L 72" (1829mm)
W 42" (1067mm)
H 22-1/2" (572mm)
(1791mm)
x 40-1/2"
(1029mm)
(1833mm)
x 40-1/2"
(1029mm)
(279mm)
A 17-3/4"
(451mm)
B 11"
C 20-1/2"
(521mm)
N/A
72-3/16"
943 lb. (428 kg)/
45 lb./sq.ft.
(219 kg/sq.m)
110 lb.
(242 kg.)
100 gal. 91 gal.
(379 l.) (345 l.)
2943
Studio
6' x 42"
N/A
L 72" (1829mm)
W 41-7/8" (1063mm)
H 22-1/2" (572mm)
(1833mm)
x 40-3/8"
(1026mm)
(279mm)
w/Tile Flange
TABLE 6
ROUGH-IN REFERENCES
MODEL SERIES 2942 & 2943
C/L DRAIN
9" x 15" (229 x 305mm)
DRAIN ASS’Y FLOOR CUTOUT
OVERFLOW
36" NOMINAL
(813mm)
OUTLINE OF
CUTOUT
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
72" NOMINAL
(1524mm)
754532-100 Rev. A
17
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR STUDIO CORNER WHIRLPOOLS AND BATH TUBS
Description
Deck
Trim
Dimensions
L-W-H
Drain /
Overflow
Height to
Underside
of Deck: C
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product Gallon to Whirlpool
Weight
Overflow Operating
Volume
988 lb. (448 kg)/
27 lb./sq.ft.
(133 kg/sq.m)
130 lb.
(59 kg.)
103 gal.
(390 l.)
65 gal.
(246 l.)
2944
Studio
Corner
Zero
(5/8")
L 83-15/16" (2132mm)
W 61-3/8" (1559mm)
H 21-1/2" (546mm)
A 15"
C 20-7/8"
(530mm)
N/A
(381mm)
B 13-1/2"
(343mm)
988 lb. (448 kg)/
27 lb./sq.ft.
(133 kg/sq.m)
130 lb.
(59 kg.)
103 gal.
(390 l.)
65 gal.
(246 l.)
2944
Studio
Corner
2"
L 84-1/4" (2139mm)
W 31-13/16" (808mm)
H 21-1/2" (546mm)
A 15"
C 19-1/2"
(495mm)
N/A
(381mm)
B 13-5/8"
(346mm)
TABLE 7
ROUGH-IN REFERENCES
MODEL SERIES 2944
59-3/4" NOMINAL
(1518mm)
OUTLINE
OF CUTOUT
61-3/4" NOMINAL
(1568mm)
9" x 18"
(229 x 457mm)
FLOOR CUTOUT
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
NOTE: PUMP EXTENDS
APPROXIMATELY
1-1/4" BEYOND TUB DECK
27-1/2"
(699mm)
45-5/8"L
(1159mm)
84" NOMINAL
(2134mm)
754532-100 Rev. A
18
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR STUDIO CORNER WHIRLPOOLS AND BATH TUBS
Description
Deck
Trim
Dimensions
L-W-H
Drain /
Overflow
Height to
Underside
of Deck: C
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product Gallon to Whirlpool
Weight
Overflow Operating
Volume
54 gal.
(246 l.)
N/A
N/A
597 lb. (271 kg)/
45 lb./sq.ft.
(219 kg/sq.m)
57 lb.
(26 kg.)
N/A
2945
Studio
L 60" (1524mm)
W 32" (813mm)
H 22" (559mm)
A 15-3/4"
(400mm)
B 10-1/4"
(260mm)
C 22-1/2"
(572mm)
60-3/16"
(1528mm)
x 30-1/2"
(774mm)
TABLE 8
ROUGH-IN REFERENCES
MODEL SERIES 2945
60"
(1524mm)
4"
10-1/4"
(260mm)
(102mm)
1-1/2"
(38mm)
16-3/8"
(411mm)
32"
(813mm)
4"
(102mm)
57"
(1448mm)
1-1/2"
(38mm)
2"(50mm)
OUTLINE
DRAIN O.D.
OF SKID
RESISTANT
SURFACE
754532-100 Rev. A
19
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR GREEN TEA WHIRLPOOLS AND BATH TUBS
Description
Dimensions
L-W-H
Drain /
Overflow
Height to
Underside
of Deck: C
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product
Weight
Gallon to
Overflow
Whirlpool
Operating
Volume
L 60" (1524mm)
W 36" (914mm)
H 21" (533mm)
3571
Green Tea
5' x 36"
A 16"
C 19"
(483mm)
58-1/2"
60-3/16"
(1529mm)
x 34-1/2"
(876mm)
3-1/2"
(89mm)
519 lb. (236 kg)/
35 lb./sq.ft.
(171 kg/sq.m)
86 lb.
(39 kg.) (197 l.)
52 gal.
38 gal.
(144 l.)
(406mm)
B 11-1/2"
(349mm)
(1485mm)
x 34-1/2"
(876mm)
3572
Green Tea
5-1/2' x 36"
A 16"
C 19"
(483mm)
64-1/2"
66-3/16"
(1681mm)
x 34-1/2"
(876mm)
3-3/4"
(95mm)
592 lb. (269 kg)/
36 lb./sq.ft.
(176 kg/sq.m)
100 lb.
(45 kg.) (223 l.)
59 gal.
44 gal.
(166 l.)
L 66" (1676mm)
W 36" (914mm)
H 21" (533mm)
(406mm)
B 11-1/2"
(349mm)
(1638mm)
x 34-1/2"
(876mm)
3573
Green Tea
6' x 36"
A 16"
C 19"
(483mm)
70-1/2"
72-3/16"
(1834mm)
x 34-1/2"
(876mm)
3-1/2"
(89mm)
665 lb. (302 kg)/
37 lb./sq.ft.
(181 kg/sq.m)
115 lb.
(52 kg.) (250 l.)
66 gal.
49 gal.
(185 l.)
L 72" (1829mm)
W 36" (914mm)
H 21" (533mm)
(406mm)
B 11-1/2"
(349mm)
(1791mm)
x 34-1/2"
(876mm)
3574
Green Tea
5' x 42"
A 16"
C 19"
(483mm)
58-1/2"
60-3/16"
3-1/8"
(79mm)
656 lb. (298 kg)/
38 lb./sq.ft.
(186 kg/sq.m)
115 lb.
(52 kg.) (246 l.)
65 gal.
47 gal.
(178 l.)
L 72" (1829mm)
W 42" (1067mm)
H 21" (533mm)
(406mm)
B 11-1/2"
(349mm)
(1485mm)
x 40-1/2"
(1029mm)
(1528mm)
x 40-1/2"
(1029mm)
3575
Green Tea
6' x 42"
A 16"
C 19"
(483mm)
70-1/2"
72-3/16"
3-1/2"
(89mm)
785 lb. (356 kg)/
37 lb./sq.ft.
(181 kg/sq.m)
127 lb.
(57 kg.) (299 l.)
79 gal.
58 gal.
(219 l.)
L 72" (1829mm)
W 42" (1067mm)
H 21" (533mm)
(40mm)
B 11-1/2"
(349mm)
(1791mm)
x 40-1/2"
(1029mm)
(1834mm)
x 40-1/2"
(1029mm)
TABLE 9
754532-100 Rev. A
20
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 3571
60"
(1524mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
36"
(914mm)
9"
C
L
(229mm)
CUTOUT IN FLOOR FOR DRAIN
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
OUTLINE OF CUTOUT 58.5" x 34.5"(1486 x 876mm)
MODEL SERIES 3572
66"
(1676mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
36"
(914mm)
9"
C
L
(229mm)
CUTOUT IN FLOOR FOR DRAIN
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
OUTLINE OF CUTOUT 64.5" x 34.5" (1638 x 876mm)
754532-100 Rev. A
21
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 3573
72"
(1829mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
36"
(914mm)
9"
C
L
(229mm)
CUTOUT IN FLOOR FOR DRAIN
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
OUTLINE OF CUTOUT 70.5" x 34.5" (1780 x 876mm)
MODEL SERIES 3574
60"
(1524mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
42"
(1067mm)
9"
C
L
(229mm)
CUTOUT IN FLOOR FOR DRAIN
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
OUTLINE OF CUTOUT 58.5" x 40.5" (1486 x 1029mm)
754532-100 Rev. A
22
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 3575
72"
(1829mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
42"
(1067mm)
9"
C
L
(229mm)
CUTOUT IN FLOOR FOR DRAIN
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
OUTLINE OF CUTOUT 70.5" x 40.5" (1780 x 1029mm)
754532-100 Rev. A
23
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS:
L
W
J
H
C
A
SIDE VIEW
END VIEW
DRAIN / OVERFLOW
B
GENERAL SPECIFICATIONS FOR SERIN WHIRLPOOLS AND BATH TUBS
Description
Dimensions
L-W-H
Drain /
Height to
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product Gallon to Whirlpool
Overflow Underside
of Deck: C
Weight
Overflow Operating
Volume
A 16-3/4" C 20"
(425mm) (508mm)
B 10-1/4"
58-1/2"
60-3/16"
(1529mm)
x 30-1/2"
(775mm)
597 lb. (271 kg)/
45 lb./sq.ft.
(219 kg/sq.m)
57 lb.
(26 kg.) (246 l.)
54 gal.
L 60" (1524mm)
W 32" (813mm)
H 23" (584mm)
3581
Serin
5' x 32"
(1486mm)
x 30-1/2"
(775mm)
(260mm)
A 16-7/8" C 20"
(429mm) (508mm)
B 9-3/4"
64-1/2"
66-3/16"
(1681mm)
x 34-1/2"
(876mm)
806 lb. (365 kg)/
49 lb./sq.ft.
(239 kg/sq.m)
65 lb.
(29 kg.) (441 l.)
97 gal.
L 66" (1676mm)
W 36" (914mm)
H 23" (584mm)
3582
Serin
5-1/2' x 36"
(1638mm)
x 34-1/2"
(876mm)
(248mm)
A 17-1/4" C 20"
(438mm) (508mm)
B 11-1/2"
68-3/16"
(1732mm)
x 36-1/2"
(927mm)
680 lb. (308 kg)/
68 lb./sq.ft.
(331 kg/sq.m)
60 lb.
(27 kg.) (409 l.)
90 gal.
L 68" (1727mm)
W 38" (965mm)
H 23" (584mm)
Template
Provided
3583
Serin
Oval
(292mm)
A 17"
(432mm) (508mm)
B 10-1/4"
C 20"
1043lb. (473 kg)/
50 lb./sq.ft.
(243 kg/sq.m)
68 lb.
(31 kg.) (568 l.)
125 gal.
L 72" (1829mm)
W 42" (1067mm)
H 23" (584mm)
72-3/16"
70-1/2"
3584
Serin
6' x 42"
(1834mm)
x 40-1/2"
(1029mm)
(1791mm)
x 40-1/2"
(1029mm)
(260mm)
TABLE 10
ROUGH-IN REFERENCES
MODEL SERIES 3581
C
L
60"
(1524mm)
OVERFLOW
30"
(762mm)
9-3/4"
(248mm)
4-1/8"
(105mm)
32"
(813mm)
9" x 12" (227 x 305mm)
CUTOUT IN FLOOR
FOR DRAIN
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
INTEGRAL
FITTING DECK
OUTLINE OF CUTOUT
754532-100 Rev. A
24
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 3582
66"
(1676mm)
33"
(838mm)
9" x 12" (227 x 305mm)
FLOOR CUTOUT
C/L
DRAIN
9-3/4"
(248mm)
4-1/8"
(105mm)
OUTLINE OF
CUTOUT
36"
(914mm)
INTEGRAL
FAUCET DECK
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
4"
(102mm)
MODEL SERIES 3583
68"
(1727mm)
34"
(864mm)
C/L
DRAIN
9"x12" (227x305mm)
FLOOR CUTOUT
11-1/2"
(292mm)
4-7/8"
(124mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
INTEGRAL
FAUCET DECK
OUTLINE OF
SKID RESISTANT
SURFACE
OUTLINE OF CUTOUT
4-3/4"
(121mm)
USE CUT-OUT TEMPLATE SUPPLLIED WITH PACKAGED TUB
754532-100 Rev. A
25
Download from Www.Somanuals.com. All Manuals Search And Download.
ROUGH-IN REFERENCES
MODEL SERIES 3584
72"
(1829mm)
36"
(914mm)
9" x 12" (227 x 305mm)
FLOOR CUTOUT
C/L
DRAIN
10-1/4"
(260mm)
4-7/8"
(124mm)
42"
(1067mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
INTEGRAL
FAUCET DECK
OUTLINE OF
OUTLINE OF
SKID RESISTANT
SURFACE
CUTPUT
754532-100 Rev. A
26
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Permit access for servicing motor as noted.
!
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
Refer to the schematics below for the appropriate bath electrical installation. Dedicated15A circuits with GFCI (Ground
Fault Circuit Interrupter) protection are required.
At initial start-up with the power ON, push the GFCI test button. The reset button should pop out. Push this button in to
reset. If the GFCI fails to operate in this manner, there is a ground fault or malfunction, indicating the possibility of
electrical shock. Turn of the power and do not use until the source of the problem has been identifed and corrected.
AIR SWITCH ACTIVATED WHIRLPOOL PUMP
ELECTRICAL
120V, 60HZ
15A GFCI
FEED
GFCI
ELECTRICAL
120V, 60HZ
15A GFCI
FEED
JUNCTION BOX (CANADA)
White
GFCI
Black
Green/Copper
GFCI OUTLET (USA)
754532-100 Rev. A
27
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
ELECTRICAL
FEED
120V, 60HZ
15A GFCI
GFCI
ELECTRONIC ACTIVATED AIR BATH (4 BUTTON PANEL)
ELECTRICAL
FEED
120V, 60HZ
15A GFCI
GFCI
ELECTRONIC ACTIVATED AIR BATH WITH LIGHTS (5 BUTTON PANEL)
754532-100 Rev. A
28
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
ECOSILENT PUMP HAS P3JJ PLUG
ELECTRICAL
FEED
120V, 60HZ
15A GFCI
GFCI
ELECTRONIC ACTIVATED ECOSILENT WHIRLPOOL (1 BUTTON PANEL)
ECOSILENT PUMP HAS P3JJ PLUG
ELECTRICAL
FEED
120V, 60HZ
15A GFCI
GFCI
ELECTRONIC ACTIVATED ECOSILENT WHIRLPOOL WITH LIGHTS (3 BUTTON PANEL)
754532-100 Rev. A
29
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
USE THREE GFCI OUTLETS (USA MARKET)
WHIRLPOOL HEATER IS
120V, 60HZ
ELECTRICAL
FEED
FACTORY INSTALLED ON
15A GFCI
COMBINATION TUBS
(FOR HEATER)
GFCI
ECOSILENT PUMP
HAS P3JJ PLUG
ELECTRICAL
FEED
120V, 60HZ
15A GFCI
GFCI
ELECTRICAL
FEED
120V, 60HZ
15A GFCI
GFCI
ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL)
754532-100 Rev. A
30
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
USE THREE JUNCTION BOXES
(CANADA MARKET)
ELECTRICAL
FEED
120V, 60HZ
15A GFCI
(FOR HEATER)
GFCI
White
Black
Green/Copper
WHIRLPOOL HEATER IS
FACTORY INSTALLED ON
COMBINATION TUBS
ECOSILENT PUMP
HAS P3JJ PLUG
ELECTRICAL
FEED
120V, 60HZ
15A GFCI
GFCI
White
Black
TO
BOX
Green/Copper
ELECTRICAL
FEED
120V, 60HZ
15A GFCI
TO
BOX
GFCI
White
Black
Green/Copper
ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL)
754532-100 Rev. A
31
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL INSTALLATION INSTRUCTIONS
(continued)
(HEATER)
Ensure the heater and pump are properly GROUNDED
and BONDED as required. Attach the 8 AWG solid
copper conductor supplied with the heater from the
heater bonding lug to the motor frame bonding lug as
shown in Figure 3.
(PUMP/MOTOR)
The conductor is secured to the lugs using set screws.
The motor frame shall have a second 8 AWG solid
copper conductor connected from the frame bonding
lug to the home’s electrical panel or approved local
bonding point as shown in Figure 3.
RUN 8 AWG SOLID COPPER
CONDUCTORS FROM
HEATER BONDING LUG TO
PUMP/MOTOR FRAME LUG
AND FROM PUMP/MOTOR
LUG TO APPROVED
NOTE: For all “EcoSilent” pump configurations, the
pump housing is plastic. Therefore, the first copper
conductor attached to the heater must be grounded
directly to the home’s electrical panel or approved local
bonding point. this type of configuration does not need
the second copper conductor shown in Figure 3.
GROUND AS SHOWN
FIRST COPPER
CONDUCTOR
SECOND
COPPER
CONDUCTOR
PUMP/MOTOR FRAME WITH
BONDING LUGS
(NOT ON “ECOSILENT” MODELS)
TO GROUND
FIGURE 3: GROUNDING DIAGRAM
WHIRLPOOL HEATER OPERATION
WARNING: Prior to operation, review the Important Safety
Instructions listed at the beginning of this instruction manual.
Once the heater is installed and the whirlpool pump is operating,
the heater is totally automatic. The heater will help maintain the
temperature of the water in the bath.
WHIRLPOOL
HEATER
ALL™
E-Z INST
HEATER “ON” LIGHT
Pressure Switch
FACTORY INSTALLED - NOT FOR RESALE
HEATER P/N: 753174-100
Bonding Lug on
Heater Housing
The heater is equipped with a preset pressure switch. The pump
must be running with water flowing in the whirlpool to allow the
heater to turn on.
FIGURE 4: WHIRLPOOL HEATER
INDICATOR LIGHT
Indicator Light
This light turns on whenever the heater is operating.
High-Limit Switch
The heater includes an exclusive “Intelligent High-Limit”. This safety circuit will not “false trip” from hot tap water.
It will only turn the heater off if the thermostat fails. If the high-limit trips frequently, call a service technician.
To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply
(1) Turn off the whirlpool pump.
(2) Drain water from the tub.
(3) Remove power from heater by unplugging at receptacle or turning off circuit breaker.
(4) The heater circuit will automatically reset in less than 15 minutes.
(5) Restore power to the heater.
(6) Whirlpool bath is now ready to use.
754532-100 Rev. A
32
Download from Www.Somanuals.com. All Manuals Search And Download.
REMOTE BLOWER LOCATION OPTION
IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular
installation makes this effort practical.
NOTE: Relocating blower motor from factory installed location, see photo 1, will require disassembly of air blower from mounting
board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final
desired position of air blower. Follow all instructions listed below.
1.
TYPICAL VIEW
NOTE: Installing the blower in a remote location will reduce the system efficiency.
NOTE: Relocating a blower motor still requires a service access for the blower.
NOTE: All materials needed for the relocation must be supplied by the installer. This includes ordering a longer control panel
cable (754025-0073A), a longer flexible blower hose (753960-2030A), and up to two lighting cable extensions for combo
models (754512-0070A).
A separate circuit, which must be protected by the Ground Fault Circuit Interrupter (GFCI), is required in the remote location.
Electrical connections should be performed by a licensed electrician.
The blower motor must be located within 12 feet of rigid piping from the bath air manifold. This limitation is for the total pipe length
and applies to any direction changes and elbows. There can be no more than six changes of direction. There should be as few
direction changes as possible and the piping installation must meet all requirements of local plumbing and building codes.
Disconnect the blower from the flexible hose as shown in photo 2. Do NOT remove the check valve manifold that is mounted to the
underside of the air bath. The manifold MUST remain mounted above the tub overflow level as shown in 2.
2.
Do NOT move check
valve manifold
TYPICAL VIEW
Replace the flexible hose shown in photo 2 with the longer flexible hose (P/N 753960-2030A) using the existing hope clamps.
NOTE: Do NOT remove the original cable coming out of the blower. Instead, plug the longer cable (P/N 754025-0073A) into the
existing cable that is coming out of the blower as shown in photo 3. Then plug the remaining end of the longer cable into
the control panel which remains on the tub wall.
TO CONTROL PANEL
TO BLOWER
3.
754025-0073A CABLE
(INCLUDES ADAPTER
BOX SHOWN)
EXISTING
CABLE
754532-100 Rev. A
33
Download from Www.Somanuals.com. All Manuals Search And Download.
REMOTE BLOWER LOCATION OPTION (continued)
FOR THE COMBINATION WHIRLPOOL / AIR BATH CONFIGURATIONS ONLY:
Up to two additional control box extensions (P/N 754512-0070A) are required as shown in photo 4 (below). Simply extend the
cables going to the blower by adding in the extension cables. Be careful not to damage the cable connections and never plug in
cables while power is applied to blower and/or pump.
PUMP
LONGER CONTROL PANEL CABLE
(754025-0073A)
CONTROL PANEL
4.
BLOWER
LIGHTS
CONTROL BOX EXTENSIONS
(754512-0070A)
754532-100 Rev. A
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation: Single Speed Whirlpool
AIR SWITCH
ELECTRONIC SWITCH
BATHING:
• Fill bath with water at a comfortable bathing temperature - If your whirlpool is equipped with the
optional EZ-Heater, it will automatically maintain the water temperature.
• IMPORTANT: Do NOT fill the whirlpool more than 2/3 full before getting in, as it may overflow.
• IMPORTANT: Do NOT add bath oils or salts – this will damage the whirlpool pump.
• IMPORTANT: Water level must be at least one inch (25mm) above the highest jet before the whirlpool is started.
Operating the system without water (dry running) for extended periods will cause pump damage and void the warranty.
• IMPORTANT: The EcoSilent whirlpool will NOT operate unless the water level is at least one inch above
the highest jet.
STARTING WHIRLPOOL:
• Press on/off button to start whirlpool.
STOPPING WHIRLPOOL:
• Press on/off button again to stop whirlpool.
AIR VOLUME CONTROL ADJUSTMENTS:
• Water turbulence is determined by the amount of air mixed with the water. Rotate the air volume control
counterclockwise for more turbulence, and clockwise for less.
FLOW JET VOLUME ADJUSTMENTS:
• Water flow-levels can be adjusted from vigorous to soft by rotating the nozzle counterclockwise for vigorous and
clockwise for soft.
• The water flow to the mini-jets in the lumbar area of bath (if so equipped) can be adjusted by turning the mini-jet
flow control valve open (counterclockwise) or closed (clockwise). the mini-jets themselves are NOT adjustable.
754532-100 Rev. A
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation: EcoSilent Whirlpool with Lights
DISPLAY COLORS
ST
1
WHITE
SLOW RAINBOW CYCLE
FAST RAINBOW CYCLE
TURQUOISE
ND
2
3
4
5
6
7
8
9
TH
TH
TH
TH
TH
TH
TH
BLUE
MAGENTA
RED
ORANGE
3-BUTTON ELECTRONIC SWITCH
YELLOW
TH
TH
10
11
GREEN
RETURN TO SLOW RAINBOW CYCLE
BATHING:
• Fill bath with water at a comfortable bathing temperature - If your whirlpool is equipped with the optional EZ-Heater,
it will automatically maintain the water temperature.
• IMPORTANT: Do NOT fill the whirlpool more than 2/3 full before getting in, as it may overflow.
• IMPORTANT: Do NOT add bath oils or salts – this will damage the whirlpool pump.
• IMPORTANT: Water level must be at least one inch (25mm) above the highest jet before the whirlpool is started.
Operating the system without water (dry running) for extended periods will cause pump damage and void the warranty.
• IMPORTANT: The EcoSilent whirlpool will NOT operate unless the water level is at least one inch above
the highest jet.
• To start whirlpool pump, press “on” button.
• To stop whirlpool pump, press “off” button.
• To turn on Chromatherapy lights, press light button once.The cycle will start on white.
• Turn off and on within 3 seconds; it will change to slow rainbow cycle and so on per the
display color table shown above.
AIR VOLUME CONTROL ADJUSTMENTS:
• Water turbulence is determined by the amount of air mixed with the water. Rotate the air volume control
counterclockwise for more turbulence, and clockwise for less.
FLOW JET VOLUME ADJUSTMENTS:
• Water flow-levels can be adjusted from vigorous to soft by rotating the nozzle counterclockwise for vigorous and
clockwise for soft.
• The water flow to the mini-jets in the lumbar area of bath (if so equipped) can be adjusted by turning the mini-jet
flow control valve open (counterclockwise) or closed (clockwise). the mini-jets themselves are NOT adjustable.
754532-100 Rev. A
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation: Air Bath
BATHING:
• Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE
• Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.
OPERATING AIR MASSAGE SYSTEM:
ON/OFF:
Press this button once to turn air-blower on.
Press again to turn air-blower off.
AIR SPEED INCREASE:
Pressing this button will increase to the next higher speed.
AIR SPEED DECREASE:
Pressing this button will decrease to the next lower speed.
WAVE FUNCTION:
Press this button to start the wave function (button will light).
Blower speed will continuously vary between high and low.
Press again to exit wave function (button light will go out).
EXITING THE BATH
• Be sure to turn off the air blower before draining bath.
• Open drain by rotating drain knob clockwise.
DRYING CYCLE OPTIONS
STANDARD DRYING CYCLE
An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the
purge cycle.
24H PROGRAMMABLE DRYING CYCLE
The system must be stopped prior to activation or deactivation.
Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button on
the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every 24 hrs. In
the event of a power failure, the program will be automatically deactivated.
Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm deactivation.
754532-100 Rev. A
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation: Air Bath with Lights
BATHING:
• Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE
• Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.
OPERATING AIR MASSAGE and CHROMATHERAPY SYSTEM:
ON/OFF:
Press this button once to turn air-blower on.
Press again to turn air-blower off.
AIR SPEED INCREASE:
Pressing this button will increase to the next higher speed.
AIR SPEED DECREASE:
Pressing this button will decrease to the next lower speed.
WAVE FUNCTION:
Press this button to start the wave function (button will light).
Blower speed will continuously vary between high and low.
Press again to exit wave function (button light will go out).
DISPLAY COLORS
ST
1
WHITE
SLOW RAINBOW CYCLE
FAST RAINBOW CYCLE
TURQUOISE
ND
2
3
4
5
6
7
8
9
TH
TH
TH
TH
TH
TH
TH
BLUE
MAGENTA
RED
ORANGE
YELLOW
TH
TH
10
11
GREEN
RETURN TO SLOW RAINBOW CYCLE
• To turn on Chromatherapy lights, press light button once.
The cycle will start on white.
• Turn off and on within 3 seconds; it will change to slow rainbow
cycle and so on per the display color table shown above.
754532-100 Rev. A
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation: Air Bath with Lights (continued)
EXITING THE BATH
• Be sure to turn off the air blower before draining bath.
• Open drain by rotating drain knob clockwise.
DRYING CYCLE OPTIONS
STANDARD DRYING CYCLE
An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the
purge cycle.
24H PROGRAMMABLE DRYING CYCLE
The system must be stopped prior to activation or deactivation.
Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button
on the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every 24
hrs. In the event of a power failure, the program will be automatically deactivated.
Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm
deactivation.
754532-100 Rev. A
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation: Combination Tub with Lights
BATHING:
• Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE
• Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.
OPERATING AIR MASSAGE and CHROMATHERAPY SYSTEM:
• Press this button to turn blower on.
• Press this button again to turn blower off.
• Press and hold button to increase blower speed. Release button
at desired speed.
• Press and hold button to decrease speed. Release button at
desired speed.
• Press button to turn whirlpool pump on.
• Press button to turn whirlpool pump off.
DISPLAY COLORS
ST
1
WHITE
SLOW RAINBOW CYCLE
FAST RAINBOW CYCLE
TURQUOISE
ND
2
3
4
5
6
7
8
9
TH
TH
TH
TH
TH
TH
TH
BLUE
MAGENTA
RED
ORANGE
YELLOW
TH
TH
10
11
GREEN
RETURN TO SLOW RAINBOW CYCLE
• To turn on Chromatherapy lights, press light button once.
The cycle will start on white.
• Turn off and on within 3 seconds; it will change to slow rainbow
cycle and so on per the display color table shown above.
754532-100 Rev. A
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation: Combination Tub with Lights (continued)
EXITING THE BATH
• Be sure to turn off the air blower before draining bath.
• Open drain by rotating drain knob clockwise.
DRYING CYCLE OPTIONS
STANDARD DRYING CYCLE
An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the
purge cycle.
24H PROGRAMMABLE DRYING CYCLE
The system must be stopped prior to activation or deactivation.
Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button
on the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every 24
hrs. In the event of a power failure, the program will be automatically deactivated.
Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm
deactivation.
754532-100 Rev. A
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Your American Standard whirlpool is designed to give you many years of pleasure with reasonable care and
maintenance.
Your new acrylic bathtub is tough, durable and easy to care for. The colors have been formulated to match other
American Standard fixtures and enhance your choice of bathroom decorations. The high gloss surface will retain its
lasting luster with proper care and maintenance.
CLEANING AND MAINTENANCE:
• Always fill the tub with temperate water. Excessively hot water (greater than 130˚ F) may cause surface damage.
• Remove bath mat after use and hang to dry.Allowing bath mat to dry in the tub may cause surface damage.
• Clean after use with a mild liquid household detergent cleaner. Do not turn on jets when such cleaners are present.
Do not use: Lestoil® Cleaner; Lysol® Disinfectant (spray or concentrate); or Lysol® Basin, Tub and Tile Cleaner;
Windex® Cleaner; Mr. Clean® Cleaner; Dow® Disinfectant Bathroom Cleaner*; or other cleaning products in
aerosol cans.
HARSH CHEMICALS, SHARP AND ABRASIVE OBJECTS
SHOULD NEVER BE USED ON ACRYLIC SURFACES
• Do not use wire brushes, knives or sharp objects to remove stains or other surface blemishes.
• Use of abrasive cleaners or powders will dull the surface. If the glossy surface looses its sheen, dulled areas can
be partially restored by rubbing with a white automotive body polishing compound and waxing with a liquid wax.
Do not wax surfaces where you walk or stand.
• Do not allow nail polish remover, acetone, dry-cleaning fluid, paint remover, or other solvents to come into contact
with the surface.
• Clean the surrounding surface immediately after using caustic drain cleaners.
Do not permit drain cleaner to enter circulation system.
• Burning cigarettes will irreparably damage the surface of the whirlpool.
CLEANING/PURGING THE CIRCULATION SYSTEM
Once every month the circulating system must be purged and cleaned. Follow the steps outlined below:
Fill whirlpool with warm water and add two teaspoons of powdered automatic dishwasher (not laundry)
detergent and one-half cup of household bleach to filled whirlpool.
1.
Activate whirlpool system in accordance with operating instructions and run system for two minutes.
Drain and refill whirlpool with cold water. Circulate for five minutes.
2.
3.
4.
Drain whirlpool completely after step 3 (above) is completed.
* Lestoil® is a registered trademark of The Clorox Company.
Lysol® is a registered trademark of The Linden Company.
Windex® is a registered trademark of S.C. Johnson and Son, Inc.
Mr. Clean® is a registered trademark of The Proctor and Gamble Company.
Dow® is a registered trademark of The Dow Chemical Company.
754532-100 Rev. A
42
Download from Www.Somanuals.com. All Manuals Search And Download.
AS America, Inc. Limited Lifetime Warranty for Premium Acrylic Air Baths
AS America, Inc. (”American Standard”) warrants to the original consumer purchaser that it will, at its option,
repair or replace this whirlpool or any of its parts that are found by American Standard, in its sole judgment,
to be defective under normal residential use and maintenance so long as it is owned by the original
consumer purchaser.
This warranty shall only become effective upon receipt by American Standard of a completely filled out
Warranty Registration Card evidencing proof of purchase.
This limited warranty does not apply to commercial installations. The warranty for commercial installations is
three (3) years.
THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY
MANNER CONTRARY TO THE INSTALLATION INSTRUCTIONS. In no event will American Standard be
liable for the cost of repair or replacement of any installation materials including but not limited to tiles, marble
etc.
This limited warranty DOES NOT COVER the following:
1. Defects or damages arising from shipping, installation, alterations, accidents, abuse, misuse, lack of
proper maintenance and cleaning as directed in the owner’s manual and use of other than genuine
American Standard replacement parts, in all cases whether caused by a plumbing contractor, service
company, the owner or any other person.
2. Deterioration through normal wear and tear and the expense of normal maintenance.
3. Commercial application.
4. Options and accessories. American Standard’s limited warranty on these items is one year for parts only
and excludes labor. This one year limited warranty covers accessories manufactured by American
Standard (e.g. aprons, drains, grab bars, heaters, trim kits) against defects of material or workmanship.
Warranty coverage begins on the date the accessory was originally purchased by the owner.
5. Postage or shipping costs for returning products for repairs or replacement under this limited warranty and
labor or other costs incurred in connection with product removal or installation under this limited warranty.
6. ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, ALL OF WHICH ARE HEREBY
EXPRESSLY DISCLAIMED, OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED
WARRANTY OF ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR
FITNESS FOR AN INTENDED PURPOSE. (Some jurisdictions do not allow limitations on how long an
implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these
limitations and exclusions may not apply to you.)
7. Responsibility for compliance with local code requirements. (Since local code requirements vary greatly
distributors, retailers, dealers, installation contractors and users of plumbing products should determine
whether there are any code restrictions on the installation or use of a specific product.)
This warranty gives you specific legal rights. You may have other legal rights that vary from state to state.
For service under this warranty, you should contact the following:
By Telephone:
1-800-442-1902
By Mail: American Standard Brands
P.O. Box 6820
Piscataway, N.J. 08855
Attention: Customer Care Center
754532-100 Rev. A
43
Download from Www.Somanuals.com. All Manuals Search And Download.
754532-100 Rev. A
44
Download from Www.Somanuals.com. All Manuals Search And Download.
|