American Dryer Corp Clothes Dryer AD 235D User Manual

AD-2 3 5 D/ AD-2 3 5 ED  
In st allat ion Man u al  
WARNING: For your safety the  
AVERTISSEMENT: Assurez-vous de bien  
suivre les instructions données dans cette  
notice pour réduire au minimum le risque  
d’incendie ou d’explosion ou pour éviter tout  
dommage matériel, toute blessure ou la mort.  
information in this manual must be  
followed to minimize the risk of fire or  
explosion or to prevent property damage,  
personal injury or death.  
Do not store or use gasoline or other flammable  
vapor and liquids in the vicinity of this or any  
other appliance.  
Ne pas entreposer ni utiliser d’essence ni  
d’autres vapeurs ou liquides inflammables dans  
le voisinage de cet appareil ou de tout autre  
appareil.  
WHAT DO YOU DO IF YOU SMELL GAS  
QUE FAIRE SI VOUS SENTEZ UNE ODEUR  
DE GAZ:  
* Do not try to light any appliance.  
* Do not touch any electrical switch; do not use  
any phone in your building.  
* Clear the room, building or area of all  
occupants.  
* Immediately call your gas supplier from a  
neighbor's phone. Follow the gas supplier's  
instructions.  
* If you cannot reach your gas supplier, call the  
fire department.  
* Ne pas tenter d’allumer d’appareil.  
* Ne touchez à aucun interrupteur. Ne pas  
vous servir des téléphones se trouvant dans  
le bâtiment où vous vous trouvez..  
* Évacuez la pièce, le bâtiment ou la zone.  
* Appelez immédiatement votre fournisseur de  
gaz depuis un voisin. Suivez les instructions  
du fournisseur.  
* Si vous ne pouvez rejoindre le fournisseur  
de gaz, appelez le service des incendies.  
Installation and service must be performed by a  
qualified installer, service agency or the gas  
supplier.  
L’installation et l’entretien doivent être assurés  
par un installateur ou un service d’entretien  
qualifié ou par le fournisseur de gaz.  
For replacement parts, contact the reseller from which the dryer  
was purchased or  
American Dryer Corporation  
88 Currant Road  
Fall River MA 02720-4781  
Telephone: (508) 678-9000 / Fax: (508) 678-9447  
ADC Part No. 113118  
110199JEV/tcosta  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT  
YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS  
SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE  
MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, or  
TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health  
Administration) STANDARDS.  
«Attention: Lor des opérations d’entretien  
des commandes étiqueter tous fils avant  
de les déconnecter. Toute erreur de  
câblage peut étre une source de danger et  
de panne.»  
“Caution: Label all wires prior to  
disconnection when servicing controls. Wiring  
errors can cause improper operation.”  
CAUTION  
DRYER(S) SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.  
WARNING  
CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYER(S).  
CHILDREN SHOULD BE SUPERVISED IF NEAR DRYER(S) IN OPERATION.  
FOR YOUR SAFETY  
DO NOT DRY MOP HEADS IN THE DRYER.  
DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.  
WARNING  
UNDER NO CIRCUMSTANCES should the door switch or the heat circuit devices  
ever be disabled.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
The dryer must never be operated with any of the back guards, outer tops, or service  
panels removed. PERSONAL INJURY or FIRE COULD RESULT.  
WARNING  
DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN  
PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED.  
IMPORTANT  
PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or  
specified in the installation manual included with the dryer.  
The wiring diagram for the dryer is located in the front electrical control box area.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ta ble of Con t en t s  
SECTION I  
IMPORTANT INFORMATION.......................................................................... 3  
A. RECEIVING and HANDLING ................................................................................................. 3  
B. SAFETY PRECAUTIONS ........................................................................................................ 4  
SECTION II  
SPECIFICATIONS .............................................................................................. 6  
A. Specifications ............................................................................................................................. 6  
SECTION III  
INSTALLATION PROCEDURES ...................................................................... 9  
A. UNPACKING/SETTING UP .................................................................................................... 9  
B. LOCATION OF THE DRYER .................................................................................................. 9  
C. DRYER ENCLOSURE REQUIREMENTS ..............................................................................11  
D. FRESH AIR SUPPLY ...............................................................................................................11  
E. EXHAUST REQUIREMENTS ................................................................................................ 13  
F. ELECTRICAL INFORMATION ............................................................................................. 17  
G. GAS INFORMATION ............................................................................................................ 21  
H. PREPARATION FOR OPERATION....................................................................................... 25  
I. PREOPERATIONAL TESTS .................................................................................................. 25  
J. SHUT DOWN INSTRUCTIONS ........................................................................................... 27  
SECTION IV  
OPERATING INSTRUCTIONS ....................................................................... 28  
A. STARTING THE DRYER ........................................................................................................ 28  
SECTION V  
SERVICE/PARTS INFORMATION ................................................................. 30  
A. SERVICE ................................................................................................................................ 30  
B. PARTS ..................................................................................................................................... 30  
SECTION VI  
WARRANTY INFORMATION ......................................................................... 31  
A. RETURNING WARRANTY CARD(S) ................................................................................... 31  
B. WARRANTY .......................................................................................................................... 31  
C. RETURNING WARRANTY PART(S) .................................................................................... 31  
SECTION VII  
ROUTINE MAINTENANCE ............................................................................ 33  
A. CLEANING ............................................................................................................................ 33  
B. ADJUSTMENTS ..................................................................................................................... 35  
C. LUBRICATION ...................................................................................................................... 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION VIII  
TROUBLESHOOTING ..................................................................................... 36  
SECTION IX  
DATA LABEL LOCATION/INFORMATION .................................................. 42  
A. Data Label .............................................................................................................................. 42  
SECTION X  
PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT  
COMPONENTS ................................................................................................ 44  
SECTION XI  
BURNER/TUMBLER HI-LIMIT MANUAL RESET INSTRUCTIONS......... 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION I  
IMPORTANT INFORMATION  
A. RECEIVING and HANDLING  
The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or  
optional box) as a means of preventing damage in transit. Upon delivery, the dryer and/or packaging, and  
wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect  
further before delivering carrier leaves.  
Dryers Damaged in Shipment:  
1. ALL dryers should be inspected upon receipt and before they are signed for.  
2. If there is suspected damage or actual damage, the trucker’s receipt should be so noted.  
3. If the dryer is damaged beyond repair, it should be refused. Those dryers which were not damaged in a  
damaged shipment should be accepted, but the number received and the number refused must be noted  
on the receipt.  
4. If you determine that the dryer was damaged after the trucker has left your location, you should call the  
delivering carrier’s freight terminal immediately and file a claim. The freight company considers this  
concealed damage. This type of freight claim is very difficult to get paid and becomes extremely difficult  
when more than a day or two passes after the freight was delivered. It is your responsibility to file freight  
claims. Dryer/parts damaged in transit cannot be claimed under warranty.  
5. Freight claims are the responsibility of the consignee, and ALL claims must be filed at the receiving end.  
ADC assumes no responsibility for freight claims or damages.  
6. If you need assistance in handling the situation, please contact the ADC Traffic Manager at  
(508) 678-9000.  
IMPORTANT: The tumbler section of the dryer must be transported and handled in an upright  
position at ALL times.  
P
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. SAFETY PRECAUTIONS  
WARNING: For your safety, the information in this manual must be followed to minimize the  
risk of fire or explosion or to prevent property damage, personal injury, or loss of  
life.  
WARNING: The dryer must never be operated with any of the back guards, outer tops, or  
service panels removed. PERSONAL INJURY or FIRE COULD RESULT.  
1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other  
appliance.  
2. Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the  
user smells gas. The instructions should be posted in a prominent location.  
3. WHAT TO DO IF YOU SMELL GAS...  
a. DO NOT try to light any appliance.  
b. DO NOT touch any electrical switch.  
c. DO NOT use any phone in your building.  
d. Clear the room, building, or area of ALL occupants.  
e. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.  
f. If you cannot reach your gas supplier, call the fire department.  
4. Installation and service must be performed by a qualified installer, service agency, or gas supplier.  
5. Dryer(s) must be exhausted to the outdoors.  
6. Although ADC produces a very versatile machine, there are some articles that, due to fabric composition  
or cleaning method, should not be dried in it.  
WARNING: Dry only water washed fabrics. DO NOT dry articles spotted or washed in dry  
cleaning solvents, a combustible detergent, or “ALL purpose” cleaner.  
EXPLOSION COULD RESULT.  
WARNING: DO NOT dry rags or articles coated or contaminated with gasoline, kerosene, oil,  
paint, or wax.  
EXPLOSION COULD RESULT.  
WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create  
a fire hazard.  
Q
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or  
similarly textured rubberlike materials. Drying in a heated basket (tumbler) may  
damage plastics or rubber and also may be a fire hazard.  
7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust  
duct work, and inside the dryer. The frequency of inspection and cleaning can best be determined from  
experience at each location.  
WARNING: The collection of lint in the burner area and exhaust duct work can create a  
potential fire hazard.  
8. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the  
National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the Canadian Electrical  
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.  
NOTE: Failure to do so will VOID THE WARRANTY.  
9. UNDER NO CIRCUMSTANCES should the dryer door switch, lint door switch, or heat safety circuit  
ever be disabled.  
WARNING: PERSONAL INJURY or FIRE COULD RESULT.  
10. This dryer is not to be used in the presence of dry cleaning solvents or fumes.  
11. Remove articles from the dryer as soon as the drying cycle has been completed.  
WARNING: Articles left in the dryer after the drying and cooling cycles have been completed  
can create a fire hazard.  
12. READ and FOLLOW ALL CAUTION and DIRECTION LABELS ATTACHED TO THE DRYER.  
WARNING: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and  
THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED  
FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING,  
ADJUSTING, INSTALLATION, or TESTING OF ANY EQUIPMENT per  
OSHA (Occupational Safety and Health Administration) STANDARDS.  
13. For safety, proper operation, and optimum performance, the dryer must not be operated with a load less  
than 66% (20 pounds [9.07 kg]) of its rated capacity.  
R
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION II  
SPECIFICATIONS  
A. SPECIFICATIONS  
MAXIMUM CAPACITY (DRY WEIGHT)  
BASKET (TUMBLER) DIAMETER  
BASKET (TUMBLER) DEPTH  
60 lbs. **  
27.2 kg  
69.22 cm  
76.2 cm  
27-1/4"  
30"  
BASKET (TUMBLER) MOTOR  
Door Opening (DIAMETER)  
BASKET (TUMBLER) VOLUME  
1/2 HP *  
21-1/2" *  
10.1 cu. ft. *  
0.373 kw  
54.61 cm  
0.286 cu.m.  
120-240v 1ø 60/50 Hz  
208-240v 3ø 60/50 Hz  
VOLTAGE AVAILABLE  
APPROX. WEIGHT (UNCRATED)  
APPROX. WEIGHT (CRATED)  
HEAT INPUT  
850 lbs.  
385.6 kg  
408.2 kg  
36,288 kcal/hr  
22.65 cmm  
--  
900 lbs.  
144,000 btu/hr **  
800 cfm **  
3/4" N.P.T.  
8"  
AIRFLOW  
INLET PIPE SIZE  
EXHAUST DUCT OUTLET  
20.32 cm  
Shaded areas are stated in metric equivalents  
*
Per basket (tumbler).  
** Total for both baskets (tumblers).  
NOTE: ADC reserves the right to make changes in specifications at any time without notice or  
obligation.  
S
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADG-235D (Gas)  
NOTE: ADC reserves the right to make changes in specifications at any time without notice or  
obligation.  
T
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADG-235ED (Gas)  
NOTE: ADC reserves the right to make changes in specifications at any time without notice or  
obligation.  
U
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION III  
INSTALLATION PROCEDURES  
Installation should be performed by competent technicians in accordance with local and state codes. In the  
absence of these codes, the installation must conform to applicableAmerican National Standards:ANSI Z223.1-  
LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical  
Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91  
(Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas  
Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical  
Connections).  
A. UNPACKING/SETTING UP  
Remove protective shipping material (i.e., plastic wrap and/or optional shipping box) from dryer.  
NOTE: The access keys for the service doors are included in the information packet shipped in  
the basket (tumbler). These keys should be removed and put in a safe place yet made  
accessible because some will be needed throughout various phases in the installation of  
the dryer.  
Dryers are shipped with a coin box and coin box faceplate ONLY. The coin box lock is not included and  
must be purchased elsewhere or the lock can be ordered as a parts order from the ADC factory.  
The dryer can be moved to its final location while still attached to the skid or with the skid removed.  
To unskid the dryer, locate and remove the four (4) bolts securing the base of the dryer to the wooden skid. Two  
(2) are at the rear of the base and two (2) are located in the front. Once the bolts are removed, slide the dryer off  
the skid.  
With the skid removed, to make it easier to slide the dryer into its final position, slightly lower ALL four (4)  
leveling legs, so that the dryer will slide on the legs instead of the base frame. The dryer is equipped with four  
(4) leveling legs, one (1) at each corner of the dryer base. The hex head adjustment bolts for the two (2) front  
leveling legs are located directly behind the lower access door, and the rear two (2) adjustments are directly  
behind the lower rear back (guard) panel.  
B. LOCATION OF THE DRYER  
Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such  
codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LATEST  
EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.  
1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (liquid propane [L.P.] Gas) or LATEST EDITION (for General  
Installation and Gas Plumbing).  
1. The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be  
removed from the floor area that the dryer is to rest on.  
IMPORTANT: “The dryer must be installed on noncombustible floors only.”  
V
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.  
3. The dryer is for use in noncombustible locations.  
4. Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply in  
Section D).  
5. Clearance provisions must be made from noncombustible construction as noted in this manual (refer to  
Dryer Enclosure Requirements in Section C).  
Even though a 12-inch (30.48 cm) clearance is acceptable, it is recommended that the rear of the dryer be  
positioned approximately 2 feet (0.61 meters) away from the nearest obstruction (i.e., wall) for ease of  
installation, maintenance, and service. (Refer to the illustration below.)  
6. provisions must be made for adequate clearances for servicing and for operation as noted in this manual  
(refer to Dryer Enclosure Requirements in Section C).  
7. Dryer must be exhausted to the outdoors in an area where correct exhaust venting can be achieved as  
noted in this manual (refer to Exhaust Requirements in Section E).  
8. Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual  
(refer to Exhaust Requirements in Section E).  
IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be  
necessary.  
NM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C. DRYER ENCLOSURE REQUIREMENTS  
Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of  
12-inches (30.48 cm), 18-inches (45.72 cm) or more is recommended for ease of installation, maintenance, and  
service) above the dryer’s outer top, except along the front of the dryer which may be closed in if desired.  
NOTE: Even though a minimum of 12-inches (30.48 cm) above the dryer’s outer top is accept  
able, a clearance of 18-inches (45.72 cm) or more is suggested for ease of installation  
and service (electrical power connections).  
NOTE: When fire sprinkler systems are located above the dryers, a minimum of 12-inches  
(30.48 cm) above the dryer’s outer top is required.  
NOTE: Allowances must be made for opening the control door.  
Dryers may be positioned side wall to side wall. However, allowances must be made for opening and closing of  
the control door and the lint door. It is suggested that the dryer be positioned about 2 feet (0.61 meters) away  
from the nearest obstruction for ease of installation, maintenance, and service (to be measured from the back  
guard). Refer to the illustration on the previous page (page 10) for details.  
NOTE: Air considerations are important for proper and efficient operation.  
D. FRESH AIR SUPPLY  
Air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An  
unrestricted source of 800 cfm (22.65 cmm) is necessary for each dryer. An unrestricted air entrance from the  
outdoors (atmosphere) of a minimum of 1-1/2 square feet (0.14 square meters) is required for each dryer. This  
area must be enlarged if louvers or registers cover the opening. It is not necessary to have a separate make-up  
air opening for each dryer. Common make-up air openings are acceptable. However, they must be set up in  
such a manner that the make-up air is distributed equally to the dryers. For example, for a bank of eight (8)  
dryers, a total make-up air opening of 12 square feet (3.66 square meters) is required. Two (2) openings  
measuring 2 feet by 3 feet (0.61 by 0.92 meters) - 6 square feet (0.56 square meters) - are acceptable. (Refer to  
the illustration on page 12.)  
Allowances must be made for remote or constricting passageways or where dryers are located at excessive  
altitudes or predominantly low-pressure areas.  
IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes.  
Make-up air that is contaminated by dry cleaning solvent fumes will result in  
irreparable damage to the motors and other dryer components.  
NN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT: Make-up air openings should not be located near duct work exhaust outlets.  
If make-up air opening(s) are too close to the exhaust outlet, lint and fumes  
may be drawn back into the dryer area through these openings.  
NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.  
NO  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E. EXHAUST REQUIREMENTS  
Exhaust duct work should be designed and installed by a qualified professional. Improperly sized duct work  
will create excessive back pressure which results in slow drying, increased use of energy, overheating of the  
dryer, and shutdown of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler) hi-heat  
thermostats.  
CAUTION: IMPROPERLY SIZED or INSTALLED EXHAUST DUCT WORK CAN  
CREATE A POTENTIAL FIRE HAZARD.  
The exhaust duct work should be laid out in such a way that the duct work travels as directly as possible to the  
outdoors with as few turns as possible. When single dryer venting is used, the duct work from the dryer to the  
outside exhaust outlet must not exceed 20 feet (6.1 meters). In the case of multiple (common) dryer venting, the  
distance from the last dryer to the outside exhaust outlet must not exceed 20 feet (6.1 meters). The shape of the  
exhaust duct work is not critical so long as the minimum cross-sectional area is provided.  
1. Single Dryer Venting  
Where possible, it is suggested to provide a separate exhaust duct for each dryer. The exhaust duct work  
should be laid out in such a way that the duct work travels as directly as possible to the outdoors with as few  
turns as possible. It is suggested that the use of 90º turns in ducting be avoided; use 30º or 45º angles  
instead. The shape of the exhaust duct work is not critical so long as the minimum cross-sectional area is  
provided.  
IMPORTANT: Exhaust back pressure measured by a manometer at each basket (tumbler)  
exhaust duct area must not exceed 0.3 inches of water column (7.4 mb).  
It is suggested that the duct work from each dryer not exceed 20 feet (6.1 meters) with no more than two (2)  
elbows. If the duct work exceeds 20 feet (6.1 meters) or has numerous elbows, the cross-sectional area of  
the duct work must be increased in proportion to length or number of elbows in it.  
IMPORTANT: For extended duct work runs, the cross-sectional area of the duct work can only  
be increased to an extent. When the duct work approaches the maximum limits  
as noted in this manual, a professional heating venting air conditioning (HVAC)  
firm should be consulted for proper venting information.  
The duct work should be smooth inside with no projections from sheet metal screws or other obstructions  
which will collect lint. When adding ducts, the duct to be added should overlap the duct to which it is to be  
connected. ALL duct work joints must be taped to prevent moisture and lint from escaping into the  
building. Also, inspection doors should be installed at strategic points in the exhaust duct work for periodic  
inspection and cleaning.  
NP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: When the exhaust duct work passes through a wall, ceiling, or roof made of combustible  
materials, the opening must be 2-inches (5.08 cm) larger than the duct (ALL the way  
around). The duct must be centered within this opening.  
To protect the outside end of the horizontal duct work from the weather, a 90º elbow bent downward should  
be installed where the exhaust exits the building. If the exhaust duct work travels vertically up through the  
roof, it should be protected from the weather by using a 180º turn to point the opening downward. In either  
case, allow at least twice the diameter of the duct between the duct opening and nearest obstruction.  
IMPORTANT: DO NOT use screens or caps on the outside opening of the exhaust duct work.  
NQ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Multiple Dryer (common) Venting  
If it is not feasible to provide separate exhaust ducts for each dryer, ducts from individual dryers may be  
channeled into a “common main duct.” The individual ducts should enter the bottom or side of the main  
duct at an angle not more than 45º in the direction of the airflow. The main duct should be tapered, with the  
diameter increasing before each individual 8-inch (20.32 cm) duct is added.  
IMPORTANT: No more than eight (8) dryers should be connected to one (1) main common  
duct. (Refer to the illustration on page 16).  
NOTE: Refer to the illustration on page 16 for examples of multiple dryer (common) venting.  
The main duct may be any shape so long as the minimum cross-sectional area is provided. The illustration  
on page 16 shows the minimum cross-sectional area for multiple dryer venting. These figures must be  
increased in proportion if the main duct run from the last dryer to where it exhausts to the outdoors is  
unusually long (over 20 feet [6.1 meters]) or has numerous elbows (more than two [2]) in it.  
IMPORTANT: For extended duct work runs, the cross section area of the duct work can only  
be increased to an extent. Maximum proportional duct work runs cannot  
exceed 20 feet (6.1 meters) more than the original limitations of 20 feet (6.1  
meters) with two (2) elbows. When the duct work approaches the maximum  
limits as noted in this manual, a professional heating venting air conditioning  
(HVAC) firm should be consulted for proper venting information  
IMPORTANT: Exhaust back pressure measured by a manometer at each basket (tumbler)  
exhaust duct area must not exceed 0.3 inches water column (W.C.) - 0.74 mb.  
The duct work should be smooth inside with no projections from sheet metal screws or other obstructions  
which will collect lint. When adding ducts, the duct to be added should overlap the duct to which it is to be  
connected. ALL duct work joints must be taped to prevent moisture and lint from escaping into the  
building. Also, inspection doors should be installed at strategic points in the exhaust duct work for periodic  
inspection and cleaning.  
NOTE: When the exhaust duct work passes through a wall, ceiling, or roof made of combustible  
materials, the opening must be 2-inches (5.08 cm) larger than the duct (ALL the way  
around). The duct must be centered within this opening.  
To protect the outside end of the horizontal duct work from the weather, a 90º elbow bent downward  
should be installed where the exhaust exits the building. If the exhaust duct work travels vertically up  
through the roof, it should be protected from the weather by using a 180º turn to point the opening  
downward. In either case, allow at least twice the diameter of the duct between the duct opening and  
nearest obstruction.  
NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT: DO NOT use screens or caps on the outside opening of the exhaust duct work.  
NS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
F. ELECTRICAL INFORMATION  
1. Electrical Requirements  
It is your responsibility to have ALL electrical connections made by a properly licensed and competent  
electrician to assure that the electrical installation is adequate and conforms with local and state regulations  
or codes. In the absence of such codes, ALL electrical connections, materials, and workmanship must  
conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST  
EDITION or in Canada, the Canadian Electrical Codes Parts 1& 2 CSAC22.1-1990 or LATEST EDITION.  
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements  
stipulated in this manual, can result in personal injury or component failure..  
NOTE: Component failure due to improper installation will VOID THE WARRANTY.  
A separate circuit servicing each dryer must be provided. The dryer must be connected to copper wire  
ONLY. DO NOT use aluminum wire which could cause a fire hazard.  
NOTE: The use of aluminum wire will VOID THE WARRANTY.  
IMPORTANT: The dryer must be connected to the electrical supply shown on the data label  
affixed to the dryer. In the case of 208 VAC or 230/240 VAC, the supply voltage  
must match the electric service specifications of the data label exactly.  
WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer  
components due to improper voltage connections will automatically VOID THE  
WARRANTY.  
NOTE: On gas dryers, to convert from 208 VAC to 230/240 VAC (or vice versa), the Direct  
Spark Ignition (DSI) transformer wiring must be changed.  
NT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Grounding  
A ground (earth) connections must be provided and installed in accordance with state and local codes. In  
the absence of these codes, grounding must conform to applicable requirements of  
the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must  
conform to applicable Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or  
LATEST EDITION. The ground connection may be to a proven earth ground at the location service panel.  
For added personal safety, when possible, it is suggested that a separate ground wire (per local codes) be  
connected from the ground connection of the dryer to a grounded cold water pipe. DO NOT ground to a  
gas pipe or hot water pipe. The grounded cold water pipe must have metal to metal connection ALL the  
way to electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic,  
rubber, or other insulating connectors, they must be jumped with no. 4 copper wire and securely clamped  
to bare metal at both ends.  
IMPORTANT: For personal safety and proper operation, the dryer must be grounded.  
3. Electrical Connections  
A wire diagram is located on the inside of the control (service) box for connection data.  
a. Single-Phase (1ø) Hookup  
The electrical connections on ALL single-phase (1ø) dryers are made into the junction box located at  
the upper rear of the dryer. A separate circuit servicing each dryer basket (tumbler) must be provided.  
NU  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SINGLE-PHASE (1Ø) ELECTRICAL CONNECTIONS LEADS  
Black  
+
White  
-
Green  
Positive  
Neutral  
Ground  
or  
L2  
Providing local codes permit, power to the dryer can be made by use of a flexible U.L. listed power  
cord/pigtail (wire size must conform to the rating of the dryer), or the dryer can be hard wired directly  
to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the  
dryer.  
4. 3-Phase (3ø) Wiring Connections  
The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes  
Neutral) and ground. Single phase (1ø) power for the control circuit and for any single-phase (1ø) motors  
(if present) is done internally to the dryer. No single-phase (1ø) input connection is required on a  
3-phase (3ø) dryer.  
a. 3-Phase (3ø) Hookup  
For gas dryers manufactured for operation at 3-phase (3ø), the electrical connections are made at the  
power distribution block located in the service box at the rear, upper left hand corner of the dryer. To  
gain access to the service box and contactor, the service box cover must be removed.  
Providing local codes permit, power to the dryer can  
be made by use of a flexible U.L. listed power cord/  
pigtail (wire size must conform to the rating of the  
dryer), or the dryer can be hard wired directly to the  
service breaker panel. In both cases, a strain relief  
must be installed where the wiring enters the dryer.  
NV  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADG-230D (Gas)  
ADG-235ED (Gas)  
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)  
IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.  
NOTE:  
A. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size  
according to appliance amp draw rating and type of breaker used.  
B. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.  
APPROX.  
SERVICE  
VOLTAGE  
WIRE  
SERVICE  
MINIMUM  
WIRE SIZE* BREAKER  
CIRCUIT  
PHASE  
AMP DRAW  
(60 Hz)  
9.6  
120  
208  
1ø  
1ø  
1ø  
3ø  
3ø  
2
2
2
3
3
14  
14  
14  
14  
14  
20  
15  
15  
15  
15  
5.8  
5.3  
2.9  
3.2  
230/240  
208  
230/240  
* AWG Stranded Type Wire...for individual lengths less than 100 feet (30.48m).  
NOTE: Contact factory for electrical information not listed.  
NOTE: ADC reserves the right to make changes in specifications at any time without notice  
or obligation.  
OM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
G. GAS INFORMATION  
It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the  
gas plumbing installation is adequate and conforms with local and state regulations or codes. In the absence of  
such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requirements  
of the National Fuel Gas CodeANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes  
CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (liquid propane [L.P.] Gas) or LATEST  
EDITION.  
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements  
stipulated in this manual, can result in personal injury and improper  
operation of the dryer.  
The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any  
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).  
The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve  
during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).  
IMPORTANT: Failure to isolate or disconnect the dryer from supply as noted can cause  
irreparable damage to the gas valve VOIDING THE WARRANTY.  
WARNING: FIRE or EXPLOSION COULD RESULT.  
1. Gas Supply  
The gas dryer installation must meet the American National Standard...National Fuel Gas Code ANSI  
Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1 M91 (Natural  
Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION, as well as local codes and ordinances  
and must be done by a qualified professional.  
NOTE: Undersized gas piping will result in ignition problems, slow drying, increased use of  
energy, and can create a safety hazard.  
The dryer must be connected to the type of heat/gas indicated on the dryer’s data label. If this information  
does not agree with the type of gas available, DO NOT operate the dryer. Contact the reseller who sold the  
dryer or the ADC factory.  
IMPORTANT: Any burner changes or conversions must be made by a qualified professional.  
The input ratings shown on the dryer’s data label are for elevations up to 2,000 feet (609.6 meters), unless  
elevation requirements of over 2,000 feet (609.6 meters) were specified at the time the dryer order was  
placed with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet  
(609.6 meters) are made by changing each burner orifice. If this conversion is necessary, contact the  
reseller who sold the dryer or contact the ADC factory.  
ON  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Technical Gas Data  
a. Gas Specifications  
TYPE OF GAS  
Natural  
3.5 inches W.C.  
Liquid Propane  
Manifold Pressure*  
Inline Pressure  
10.5 inches W.C.  
8.7 mb  
26.1 mb  
26.1 mb  
6.0 - 12.0 inches W.C.  
10.5 inches W.C.  
14.92 - 29.9 mb  
Shaded areas are stated in metric equivalents  
* Measured at gas valve pressure tap when the gas valve in on.  
b. Gas Connections:  
Inlet connection -------------- 3/4-inch N.P.T.  
Inlet supply size ------------- 3/4-inch N.P.T. (minimum)  
Btu/hr input (per dryer) ----- 144,000 (36,288 kcal/hr)  
Btu/hr input (per pocket) --- 72,000 (18,144 kcal/hr)  
1) Natural Gas  
Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure  
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches  
water column (W.C.) - 29.9 mb - pressure.  
2) Liquid Propane (L.P.) Gas  
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so  
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas  
valve pressure tap must be a consistent 10.5 inches water column (26.1 mb.) There is no regulator  
or regulation provided in a L.P. dryer. The water column pressure must be regulated at the source  
(L.P. tank) or an external regulator must be added to each dryer.  
TYPE OF GAS  
Liquid Propane  
(L.P.)  
Conversion Kit  
Part Number  
ADC  
MODEL  
NUMBER  
BTU  
Per Hour  
Rating  
Natural  
Liquid Propane (L.P.)  
kcal/hr  
Rating **  
Part  
Number  
Part  
Number  
Qty.** D.M.S.*  
Qty.** D.M.S.*  
ADG-230D  
ADG-235ED  
72,000  
18,144  
1
#20  
140828  
1
#41  
140811  
874059  
Shaded area is stated in metric equivalent  
*
D.M.S. (Drill Material Size) equivalents are as follows:  
** Each pocket/tumbler  
Natural Gas ............... #20 = .1610" (4.089 mm)  
Liquid Propane Gas .. #41 = .0960" (2.438 mm)  
OO  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Piping Connections  
ALL components/materials must conform to National Fuel Gas Code SpecificationsANSI Z223.1-LATEST  
EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (liquid propane  
[L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and  
ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet  
applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance  
BTUs being supplied.  
The dryer is provided with a 3/4-inch N.P.T. inlet pipe connection located at the upper right hand corner  
(when viewed from the rear ) of the dryer. The minimum pipe size (supply line) to the dryer is 3/4” N.P.T.  
For ease of servicing, the gas supply line of each dryer must have its own shutoff valve.  
The size of the main gas supply line (header) will vary depending on the distance this line travels from the  
gas meter (or in the case of L.P. gas, the supply tank), the number of tees, other gas operated appliances on  
the supply line, etc. Specific information regarding supply line size should be determined by the gas  
supplier.  
NOTE: Undersized gas supply piping can create a low or inconsistent pressure which will result  
in erratic operation of the burner ignition system.  
Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch pipe loop be  
installed in the supply line servicing the bank of dryers. An in-line pressure regulator must be installed in  
the gas supply line (header) if (natural) gas line pressure exceeds 12.0 inches water column pressure  
(29.2 mb.) Refer to the illustration on the following page [page 24] for details.  
IMPORTANT: Water column pressure of 3.5 inches (8.7 mb) for natural gas dryers and  
10.5 inches (26.1 mb) for L.P. gas is required at the gas valve pressure tap  
of each dryer for proper and safe operation.  
An 1/8-inch N.P.T. plugged tap, accessible for a test gauge connection, must be installed in the main gas  
supply line immediately upstream of each dryer.  
IMPORTANT: Pipe joint compounds that resist the action of natural gas and L.P. gas must be  
used.  
IMPORTANT: Test ALL connections for leaks by brushing on a soapy water solution (liquid  
detergent works well).  
OP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!  
IMPORTANT: The dryer and its individual shutoff valve must be disconnected from the gas  
supply piping system during any pressure testing of that system at test pressures  
in excess of 1/2 psig (3.5 kPa).  
NOTE: The dryer must be isolated from the gas supply piping system by closing its individual  
manual shutoff valve during any pressure test of the gas supply system at test pressures  
equal to or less than 1/2 psig (3.5 kPa).  
OQ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
H. PREPARATION FOR OPERATION  
The following items should be checked before attempting to operate the dryer:  
1. Read ALL CAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.  
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer’s data label affixed on  
the back of the dryer control (service) door.  
3. GAS MODELS - check to assure that the dryer is connected to the type of heat/gas indicated on the  
dryer’s data label.  
4. GAS & ELECTRIC MODELS - the sail switch damper assembly was installed and adjusted at the  
factory prior to shipping. However, each sail switch adjustment must  
be checked to assure that this important safety control is functioning.  
5. Check bolts, nuts, screws, terminals, and fittings for tightness.  
6. GAS MODELS - be sure that ALL gas shutoff valves are in the open position.  
7. Be sure ALL back guard panels and service box covers have been replaced.  
8. Check the lint door to assure that it is closed and secured in place.  
9. Rotate the basket (tumbler) by hand to be sure it moves freely.  
I. PREOPERATIONAL TESTS  
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test  
should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or  
due to marginal location (installation) conditions.  
1. Turn on electric power to the dryer.  
a. COIN MODELS ONLY  
1) The light emitting diode (L.E.D.) display(s) will flash back and forth between “FILL” and the  
amount needed to start the dryer (i.e., “25”), meaning that the dryer is available and 25¢ is required  
to start it.  
2) Insert the proper number of coins into coin acceptor. Once the correct amount needed to start the  
dryer has been inserted, the L.E.D. display(s) will read “PUSH.”  
3) Start the dryer by pressing the desired setting (i.e., “LO” selection for the upper basket/tumbler).  
The L.E.D. display will now read the selection (setting) made and the amount of time vended (i.e.,  
“LO 10”).  
NOTE: The dryer can be stopped at any time by opening the main door. To restart dryer,  
shut the main door and press desired setting.  
OR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4) Open main door to stop the dryer, and change selection to “PERM PRESS” (medium) setting.  
Repeat this procedure, but change the selection (setting) to “HI” (high). This will confirm that  
setting key circuits and door switch circuits are functioning properly.  
5) Repeat above procedure for the other basket (tumbler).  
b. OPL (NON-COIN) MODELS ONLY  
1) The light emitting diode (L.E.D.) display(s) will read “FILL” meaning that the dryer is available.  
2) Start the dryer by pressing the “E” of the keyboard (touch pad). The L.E.D. display will quickly  
show “Ld 30,” “LC 04,” “F 180.” The dryer will start and the L.E.D. display will show “dr 30.”  
NOTE: The dryer can be stopped at any time by opening the main door. To restart the dryer,  
shut the main door and press “ENTER/START.”  
3) Repeat above procedure for the other basket (tumbler).  
2. Heat Circuit Operational Test.  
a. When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first  
ignition attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for  
the air to be purged from the lines.  
NOTE:  
During the purging period, check to be sure that ALL gas shutoff valves are open.  
NOTE: Gas dryers are equipped with a Direct Spark Ignition (DSI) system which has internal  
diagnostics. If ignition is not established after the first attempt, the heat circuit in the DSI  
module will lockout until it is manually reset. To reset the DSI system, open and close  
the main door and restart the dryer.  
b. Once ignition is established, a gas pressure test should be taken at the gas valve pressure tap of each  
dryer to assure that the water column pressure is correct and consistent.  
NOTE: Water column pressure requirements (measured at the pressure tap of the gas valve body):  
Natural Gas................................... 3.5 Inches Water Column (8.7 mb).  
Liquid Propane (L.P.) Gas ............ 10.5 Inches Water Column (26.1 mb).  
IMPORTANT: There is no regulator provided in a L.P. Dryer. The water column (W.C.)  
pressure must be regulated at the source (L.P. tank) or an external regulator  
must be added to each dryer.  
3. Make a complete operational check of ALL the operating controls to insure that the timing is correct and  
that the temperatures are set properly.  
OS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Make a complete operational check of ALL safety-related circuits (i.e., door switches, hi-limit thermostats,  
sail switches, basket [tumbler] safety thermostats, etc.).  
NOTE: The sail switch can be checked for proper operation by opening the control door while  
the dryer is running and the heating unit (burner) active (on). The heating unit(s) should  
shut off within a few seconds. If not, make the necessary adjustments.  
5. Each basket (tumbler) should be operated through one (1) complete cycle to assure that no further  
adjustments are necessary and that ALL components are functioning properly.  
BASKET COATING  
The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth  
material with a solution of water and nonflammable mild detergent and tumbling them in the basket  
(tumbler) to remove this coating.  
NOTE: Drying and cooling cycles are complete when the light emitting diode (L.E.D.) display  
reads “donE.”  
6. Computer Programs/Selections...  
Each microprocessor controller (computer) has been preprogrammed by the factory with the most  
commonly used program (parameter) selections. If microprocessor controller (computer) program changes  
are required, refer to the computer programming manual which was shipped with the dryer.  
7. On models manufactured for 3-phase (3ø) electrical input voltage, check the electrical service phase  
sequence. While the dryer is operating, check to see if the baskets (tumblers) are rotating in the clockwise  
(CW) direction (when viewed from the front of the dryer). If the baskets (tumblers) rotate counterclockwise  
(CCW), the phasing is incorrect. Reverse the two (2) leads at connections L1, L2, or L3 of the power  
supply to the dryer.  
J. SHUT DOWN INSTRUCTIONS  
In the case where the dryer is to be shut down (taken out of service) for a period of time, the following must be  
performed:  
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.  
2. Discontinue the gas supply (for gas models Only):  
a. SHUT OFF external gas supply shutoff valve (for both the top basket [tumbler] and the bottom  
basket [tumbler] where the independent supply line for each basket [tumbler] is used).  
b. SHUT OFF internal gas supply shutoff valve located in the gas valve burner area (for both the  
top basket [tumbler] and the bottom basket [tumbler]).  
OT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION IV  
OPERATING INSTRUCTIONS  
A. STARTING THE DRYER  
The dryer is available for use when the appropriate microprocessor controller (computer) light emitting diode  
(L.E.D.) display reads “FILL” and/or the amount needed to start the dryer (i.e., “25”). Once the load has been  
put into the dryer and the main door is closed, start the dryer as follows:  
1. Insert the proper number of coins into the coin acceptor. Once the correct “Amount To Start” has been  
inserted, the L.E.D. display will read “PUSH.”  
2. Determine fabric setting (selection). Setting “HI TEMP” is the high temperature range, “PERM PRESS” is  
the medium-range temperature setting, and “LO TEMP” is the low-range temperature.  
Once the fabric temperature setting (selection) has been determined, start the dryer by pressing the fabric  
setting key.  
3. The dryer will now start, and the L.E.D. display will read the setting and the time vended (i.e., “LO 10”).  
4. The cycle time will count down until the drying and cooling cycles are completed.  
5. Upon completion of the drying cycle and cooling cycle, the dryer will shut off, the tone (buzzer) will sound  
for 5-seconds, and the L.E.D. display will read “donE.”  
NOTE: If the Anti-Wrinkle program is active, the L.E.D. display will remain reading “donE,”  
and the microprocessor controller (computer) will proceed through the Anti-Wrinkle  
program until the maximum “Active Guard Time” has expired or until the main door is  
opened, whichever comes first.  
NOTE: If the Anti-Wrinkle program is not active or in use, the L.E.D. display will read “donE”  
until the main door is opened, at which time, the L.E.D. display will read “FILL” and/or  
the “Amount To Start.”  
a. Notes  
1) The dryer basket (tumbler) can be stopped at any time by opening the main door. To restart dryer,  
shut the main door and press desired setting.  
OU  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: When a cycle is interrupted by opening the main door, the cycle time will continue to  
count downward, regardless if the door is open or closed until a keyboard (touch pad)  
selection is made.  
2) Selection (setting) changes can be made at any time during the drying cycle by opening and  
closing the main door and then making a new selection.  
3) Additional time can be purchased at any time. If the dryer is in operation (drying mode) and  
additional coins are inserted, the light emitting diode (L.E.D.) display will change to display the  
appropriate time vended.  
OV  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION V  
SERVICE/PARTS INFORMATION  
A. SERVICE  
1. Only properly licensed or trained technicians should service the dryer. If service is required, contact the  
reseller from whom the ADC equipment was purchased. If the reseller cannot be contacted or is  
unknown, contact the ADC Service Department for a reseller in your area.  
NOTE: When contacting the ADC Service Department, be sure to give them the correct model  
number and serial number so that your inquiry is handled in an expeditious manner.  
B. PARTS  
1. Replacement parts should be purchased from the reseller from whom the ADC equipment was  
purchased. If the reseller cannot be contacted or is unknown, contact the ADC Parts Department for a  
reseller in your area. Parts may also be purchased directly from the factory by calling the ADC Parts  
Department at (508) 678-9000 or you may FAX in your order at (508) 678-9447.  
NOTE: When ordering replacement parts from the ADC dealer or the ADC factory be sure to  
give them the correct model number and serial number so that your parts order can be  
processed in an expeditious manner.  
PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION VI  
WARRANTY INFORMATION  
A. RETURNING WARRANTY CARD(S)  
1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main  
door glass. These warranty cards are intended to serve the customer where we record the individual  
installation date and warranty information to better serve you, if you file a warranty claim.  
a. If a warranty card did not come with your dryer, contact the ADC Warranty Department or the ADC  
Service Department at (508) 678-9000.  
IMPORTANT: A separate warranty card must be completed and returned for each individual  
dryer.  
NOTE: Be sure to include the installation date when returning warranty card(s).  
B. WARRANTY  
For a copy of the ADC commercial warranty covering your particular dryer(s), contact the ADC reseller from  
whom you purchased the equipment and request a dryer warranty form. If the reseller cannot be contacted or is  
unknown, warranty information can be obtained from the factory by contacting the ADC Warranty Department  
at (508) 678-9000.  
NOTE: Whenever contacting the ADC factory for warranty or warranty information, be sure to  
have the dryer’s model number and serial number available so that your inquiry can be  
handled in an expeditious manner.  
C. RETURNING WARRANTY PART(S)  
ADC has a Warranty Parts Department that handles ALL returned warranted merchandise. To expedite  
processing, the following procedures must be followed:  
1. No parts are to be returned to ADC without prior written authorization (“Return Material Authorization”  
[R.M.A.]) from the factory.  
NOTE: A R.M.A. is valid for only sixty (60) days from date of issue.  
PN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
a. The R.M.A. issued by the factory, as well as any other correspondence pertaining to the returned part(s),  
must be included inside the package with the failed merchandise.  
2. Each part must be tagged with the following information:  
a. Model number and serial number of the dryer from which part was removed.  
b. Nature of failure (be specific).  
c. Date of dryer installation.  
d. Date of part failure.  
e. Specify whether the part(s) being returned is for a replacement, a credit, or a refund.  
NOTE: If a part is marked for a credit or a refund, the invoice number covering the purchase of  
the replacement part must be provided.  
NOTE: Warranty tags (ADC Part No. 450064) are available at “no charge” from ADC upon  
request.  
3. The company returning the part(s) must clearly note the complete company name and address on the  
outside of the package.  
4. ALL returns must be properly packaged to insure that they are not damaged in transit. Damage claims  
are the responsibility of the shipper.  
IMPORTANT: No replacements, credits, or refunds will be issued for merchandise damaged in  
transit.  
5. ALL returns should be shipped to the ADC factory in such a manner that they are insured and a proof of  
delivery can be obtained by the sender.  
6. Shipping charges are not the responsibility of ADC. ALL returns should be “prepaid” to the  
factory. Any “C.O.D.” or “COLLECT” returns will not be accepted.  
IMPORTANT: No replacements, credits, or refunds will be issued if the claim cannot be  
processed due to insufficient information. The party filing the claim will be  
notified in writing, either by “FAX” or “CERTIFIED MAIL - Return Receipt  
Requested,” as to the information necessary to process claim. If a reply is not  
received by the ADC Warranty Department within thirty (30) days from the  
FAX/letter date, then no replacement, credit, or refund will be issued, and the  
merchandise will be discarded.  
PO  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION VII  
ROUTINE MAINTENANCE  
A. CLEANING  
A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from  
various areas of the dryer, as well as throughout the duct work system. The frequency of cleaning can best be  
determined from experience at each location. Maximum operating efficiency is dependent upon proper air  
circulation. The accumulation of lint can restrict this airflow. If the guidelines in this section are met, an ADC  
dryer will provide many years of efficient, trouble-free, and most importantly safe operation.  
WARNING: LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE. THE  
ACCUMULATION OF LINT CAN CREATE A POTENTIAL FIRE  
HAZARD.  
WARNING: KEEP DRYER AREA CLEAR and FREE FROM COMBUSTIBLE  
MATERIALS, GASOLINE, and OTHER FLAMMABLE VAPORS and  
LIQUIDS.  
NOTE: Suggested time intervals shown are for average usage which is considered six (6) to  
eight (8) operational (running) hours per day.  
SUGGESTED CLEANING SCHEDULE  
DAILY (beginning of each work shift)  
Clean lint from basket(s)/tumbler(s).  
Inspect lint screen(s)/drawer(s) for damage and replace if torn.  
WEEKLY  
Clean lint accumulation from around microprocessor temperature sensor probes and sensor bracket  
assemblies.  
PP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
90 DAYS  
Remove lint from the motor air vents and surrounding area.  
IMPORTANT: Lint accumulation will restrict the airflow over the motor(s), causing overheating  
and irreparable motor damage. Motor failure due to lint accumulation will  
VOID THE WARRANTY.  
Remove lint accumulation from around the openings in the dryer’s back panels.  
Remove lint from gas valve burner train area with a dusting brush or vacuum cleaner attachment.  
Remove any lint accumulation from the coin acceptor area, including the optical switch.  
Inspect and remove lint accumulation in customer furnished exhaust duct work system and from the dryer’s  
internal exhaust ducting.  
WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN  
CREATE A POTENTIAL FIRE HAZARD.  
WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AIR and VENTILATION  
AIR.  
Inspect and remove lint accumulation from the dryer’s exhaust duct work back draft dampers.  
NOTE: A back draft damper that is sticking partially closed can result in slow drying and  
shutdown of the heat circuit safety switches and/or thermostats.  
EVERY 6 MONTHS  
In the cleaning of the dryer cabinet, avoid using harsh abrasives. A product for the cleaning of appliances is  
recommended.  
ALL bearings and set screws should be checked to insure they are tight.  
PQ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. ADJUSTMENTS  
7 DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTER  
Inspect bolts, nuts, screws (bearing set screws), nonpermanent gas connections (unions, shutoff valves, orifices,  
etc.), electrical terminations, and grounding connections.  
Motor and drive belts should be examined. A cracked or seriously frayed belt(s) should be replaced. Tighten  
loose belt(s) when necessary and check the alignment.  
Complete operational check of controls and valves.  
Complete operational check of ALL safety devices (door switches, lint compartment switches, sail switches,  
burner, and hi-limit thermostats).  
C. LUBRICATION  
The motor bearings, idler bearings, and under normal/most conditions the tumbler bearings are permanently  
lubricated. It is physically possible to re-lubricate the tumbler bearings if you chose to do so even though this  
practice is not necessary. Use Shell Alvania #2 grease or its equivalent. The tumbler bearings used in the dryer  
DO NOT have a grease fitting. Provisions are made in the bearing housing for the addition of a grease fitting  
which can be obtained elsewhere, or from ADC by ordering kit Part No. 882159 (includes two [2] fittings).  
PR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION VIII  
TROUBLESHOOTING  
IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY  
and THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE  
REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR  
CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY  
EQUIPMENT per OSHA (Occupational Safety and Health Administration)  
STANDARDS.  
The information provided will help isolate the most probable component(s) associated with the difficulty  
described. The experienced technician realizes, however, that a loose connection or broken/shorted wire may be  
at fault where electrical components are concerned ... and not necessarily the suspected component itself.  
Electrical parts should always be checked for failure before being returned to the factory.  
The information provided should not be misconstrued as a handbook for use by an untrained person making  
repairs.  
IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the  
fuse being replaced.  
WARNING: ALL SERVICE and TROUBLESHOOTING SHOULD BE PERFORMED BYA  
QUALIFIED PROFESSIONAL or SERVICE AGENCY.  
WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS  
DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.  
A. No light emitting diode (L.E.D.) display...  
1. Service panel fuse blown or tripped breaker.  
2. Blown control circuit fuse (1/2-Amp [slo blo] fuse).  
3. Failed microprocessor controller (computer).  
B. Basket (tumbler) motor does not start, microprocessor controller (computer) shows drying  
cycle in progress and L.E.D. motor indicator dot is on...  
1. Microprocessor controller (computer) indicator is on ...  
a. Failed motor contactor (relay).  
b. Failed motor.  
PS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Microprocessor controller (computer) indicator is off (and the light emitting diode [L.E.D.] display does  
not read “door”) ...  
a. Failed microprocessor controller (computer).  
C. The dryer will not stop, even with no cycle (L.E.D. display reads “FILL”) in progress...  
1. Failed motor contactor/relay.  
D. The dryer operates for a few minutes, and with the microprocessor controller (computer)  
motor L.E.D. indicator dot on the motor stops, and then after a period of time restarts on it’s  
own...  
1. Motor is overheating and tripping out on its internal overload ...  
a. Motor air vents clogged with lint.  
b. Low voltage to motor.  
E. The dryer operates for a few minutes and then stops...microprocessor controller (computer)  
L.E.D. display continues to read cycle in progress, indicator dots are off and dryer can be  
restarted by pressing selection key...  
1. Intermittent connection in main door circuit.  
F. Microprocessor controller (computer) L.E.D. display reads “dSFL”...  
1. L.E.D. display consistently reads “dSFL” and will not clear ...  
a. Microprocessor controller (computer) 1/8-Amp (slo blo) fuse is blown.  
b. Failed microprocessor controller (computer) temperature sensor.  
c. Broken wire and/or termination in sensor harness somewhere between the sensor bracket and the  
microprocessor controller (computer).  
d. Failed microprocessor controller (computer).  
2. L.E.D. display reads “dSFL” for a short period of time (30-seconds or less) and then returns to the normal  
“FILL” mode...  
NOTE: Once the microprocessor controller (computer) detects a problem, it updates every  
30-seconds so that if a problem was a loose connection in this circuit which corrected  
itself, the “dSFL” display condition would automatically be cancelled.  
a. Loose wire and/or termination in sensor harness somewhere between the sensor bracket and the  
microprocessor controller (computer).  
b. Failed microprocessor controller (computer) temperature sensor.  
PT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
G. Microprocessor controller (computer) light emitting diode (L.E.D.) display reads “Hot”...  
The “Hot” display condition indicates a possible overheating condition. The microprocessor controller  
(computer) monitors the temperature in the dryer at ALL times. If the microprocessor detects that the  
temperature in the dryer has exceeded 220º F (104º C), it will disable ALL of the dryer outputs (shut the  
dryer down), the buzzer (tone) will sound for approximately 5-seconds, and the L.E.D. display will read  
“Hot.” The L.E.D. display will continue to read “Hot” until the temperature has dropped to 220º F (104º C)  
or lower and the microprocessor controller (computer) is manually reset by closing and opening the Program  
Switch (PS).  
Possible reasons for overheating ...  
1. Restriction in location exhaust duct work ...  
a. Dryer exhaust damper stuck in closed position.  
b. Undersized exhaust duct work.  
2. Insufficient make-up air.  
H. Microprocessor controller (computer) L.E.D. display reads “SEFL”...  
The “SEFL” display condition indicates a rotational sensor circuit failure which means that there is a fault  
somewhere in the basket (tumbler) rotation detection circuit ... or ... the microprocessor controller  
(computer) program related to this circuit (PL01) is set incorrectly in the active mode (“SEn”) where the  
dryer is not equipped with the optional rotation sensor and should be set in the nonactive mode (“nSEN”).  
If the dryer is equipped with the optional rotational sensor and for whatever reason the microprocessor  
controller (computer) detects that the basket (tumbler) is not turning, it will disable ALL of the dryer  
outputs (shut the dryer down), and the L.E.D. display will read “SEFL.” The L.E.D. display will continue  
to read “SEFL” until the microprocessor is manually reset by closing and opening the Program Switch (PS).  
Possible causes:  
1. Loose/slipping (out of proper adjustment) basket/tumbler and/or idler belt.  
2. Broken basket (tumbler) and/or idler belt.  
3. Failed motor (refer to Item B on page 36 and page 37).  
4. Failure in the rotational sensor circuit ...  
a. Failed rotational sensor.  
b. Loose connection or break between the rotation sensor and the microprocessor controller (computer).  
I. Microprocessor controller (computer) will not accept any, or only accept certain keyboard  
(touch pad) entries...  
1. Failed keyboard (touch pad) label assembly.  
2. Failed microprocessor controller (computer).  
PU  
Download from Www.Somanuals.com. All Manuals Search And Download.  
J. Microprocessor controller (computer) locks up and the light emitting diode (L.E.D.) display  
reads erroneous message(s) or only partial segments...  
1. Transient power voltage (spikes)...disconnect power to the dryer, wait one (1) minute (NOTE: for dryer  
models with the optional battery backup...disconnect battery), then reestablish power to the dryer. If problem  
is still evident, proceed to Item J2 thru Item J4 below.  
2. Failed keyboard (touch pad) label assembly.  
3. Improper grounding of the dryer or the microprocessor controller (computer) ground connections to the  
panel or the dryer are not proper.  
4. Failed microprocessor controller (computer).  
K. Dryer stops during a cycle and the microprocessor controller (computer) L.E.D. display  
returns to “FILL”...  
If the dryer is equipped with optional battery backup ...  
1. Refer to Item J1, Item J3, or Item J4 above.  
a. If the dryer is not equipped with optional battery backup ...  
1) Loose connection somewhere in the power source to the dryer.  
2) Loose connection in main power circuit to the microprocessor controller (computer).  
3) Improper grounding of the dryer or the microprocessor controller (computer) ground  
connections to the panel or the dryer are not proper.  
4) Failed microprocessor controller (computer).  
L. Heating unit is not operating (no heat)... basket (tumbler) is turning, microprocessor controller  
(computer) heat indicator dot is on but “HEAT” output L.E.D. is not...  
1. Failed microprocessor controller (computer).  
M. Gas heating unit is not operating (no heat)... both microprocessor controller (computer) heat  
indicator dot and “HEAT” indicator are on... but no spark at burner area when the dryer is  
first started...  
1. Fault in sail switch circuit ...  
a. Sail switch is out of adjustment or has failed.  
b. Sail switch damper is not closing or is fluttering ...  
1) Lint drawer/screen is dirty or clogged.  
2) Restriction in exhaust duct work.  
3) No exhaust airflow.  
PV  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Fault in burner hi-limit circuit or tripped manual reset hi-limit thermostat.  
3. Fault in basket (tumbler) hi-limit circuit or tripped manual reset hi-limit thermostat.  
4. Failed Direct Spark Ignition (DSI) module (burner control).  
5. Failed DSI ignitor and/or flame-probe assembly.  
N. No heat... ignitor sparks but there is no flame at burner...  
1. DSI ignitor probe out of adjustment...  
a. Reposition ignitor assembly closer to the burner ribbon area. Also, check to make sure ribbon in  
burner is flush ALL around the top of the burner tube (ribbon should not stick up at any area).  
b. Check gap between ignitor assembly and top of burner. Gap must be set 1/8” ± 1/32” (3.175 ± 0.79248 mm)  
2. Failed ignitor flame-probe assembly or problem with wiring connections to the assembly.  
3. No gas (check shutoff valves) or insufficient (low water column [W.C.] pressure) gas supply.  
4. Failed DSI module.  
5. Failed gas valve.  
O. No heat... ignitor sparks, burner goes on and off right away...  
1. DSI flame sensor (probe) out of adjustment...reposition closer to the flame area.  
2. Failed DSI flame sensor probe.  
3. Sail switch is fluttering ...  
a. Lint drawer/screen is dirty or clogged.  
b. Restriction in exhaust duct work.  
4. Insufficient make-up air.  
5. Failed Direct Spark Ignition (DSI) module.  
P. Dryer operates, but is taking too long to dry...  
1. Exhaust duct work run is too long or is undersized...back pressure cannot exceed 0.3 inches Water  
Column (0.74 mb).  
2. Low and/or inconsistent gas pressure.  
3. Insufficient make-up air.  
4. Poor air/gas mixture at burner...yellow or poor flame pattern...adjust gas burner air adjustment shutters.  
5. Lint drawer/screen is not being cleaned out on a regular basis or often enough.  
QM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Extractors (washers) are not performing properly.  
7. Sail switch is fluttering... restriction in exhaust.  
8. Failed microprocessor temperature sensor...temperature calibration is inaccurate.  
9. Failed microprocessor controller (computer)...temperature calibration is inaccurate.  
10. Lint accumulation in location exhaust system.  
Q. Condensation on main door glass...  
1. Too long, undersized, or improperly installed duct work.  
2. Exhaust back draft damper is stuck closed or partially closed.  
3. Restriction in exhaust duct work.  
R. Dryer is making scraping noise at basket (tumbler) wrapper area...  
1. Check for object(s) caught in the basket (tumbler) wrapper area.  
2. Basket (tumbler) is out of proper alignment ...  
a. Check both the vertical alignment and lateral alignment.  
b. Check gap between the front panel and the basket (tumbler) front...set screws may have come loose  
and basket (tumbler) walked forwards or backwards.  
3. Loose or broken basket (tumbler) tie rod.  
4. Broken basket (tumbler) support.  
S. Excessive noise and/or vibration...  
1. Dryer is not leveled properly.  
2. Impellor (fan) out of balance or broken.  
3. Loose basket (tumbler) tie rod.  
4. Basket (tumbler) is out of adjustment or adjustment bolts (hardware) loose.  
5. Loose motor or motor mount assembly.  
QN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION IX  
DATA LABEL LOCATION/INFORMATION  
A. DATA LABEL  
Contact American Dryer Corporation  
When contacting American Dryer Corporation, certain information is required to insure proper service/parts  
information from ADC. This information is on the data label that is located in the left inside front side panel (as  
shown in the illustration above). When contacting ADC please have the model number as well as the serial  
number readily available.  
QO  
Download from Www.Somanuals.com. All Manuals Search And Download.  
THE DATA LABEL  
1. MODEL NUMBER  
The model number is an ADC number which describes the size of the dryer and the  
type of heat (gas, electric, or steam).  
2. SERIAL NUMBER  
The serial number allows ADC to gather information on your particular dryer.  
3. MANUFACTURING CODE NUMBER  
The manufacturing code number is a number issued by ADC which describes  
ALL possible options on your particular model.  
4. TYPE OF HEAT  
This describes the type heat for your particular dryer; gas (either natural gas or liquid  
propane [L.P.]) or steam.  
5. HEAT INPUT (for GAS DRYERS)  
This describes the heat input in British Thermal Units per Hour (BTUH).  
6. ORIFICE SIZE (for GAS DRYERS)  
Gives the number drill size used.  
7. ELECTRIC SERVICE  
This describes the electric service for your particular model.  
8. GAS MANIFOLD PRESSURE (for GAS DRYERS)  
This describes the manifold pressure taken at the gas valve tap.  
9. APPLICABLE APPROVAL SEAL(S)  
I.e., Canadian Standards Association International.  
QP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION X  
PROCEDURE FOR FUNCTIONAL CHECK  
OF REPLACEMENT COMPONENTS  
1. Microprocessor Controller (computer) Board  
a. Upon completing installation of the replacement microprocessor controller (computer) board, reestablish  
power to the dryer.  
b. Start the drying cycle.  
c. Verify that the motors and the heat indicator dots, in the microprocessor controller (computer) light  
emitting diode (L.E.D.) display are on. (Refer to the illustration below.)  
d. Verify that motor’s heat and door indicator lights on the back side of the microprocessor controller  
(computer) board are lit. (Refer to illustration below.)  
QQ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
e. Open main door. The dryer must stop and ALL indicator lights on the back side of the microprocessor  
controller (computer) board must go out.  
f. Try to restart the dryer with the main door open.  
g. The microprocessor controller (computer) board’s light emitting diode (L.E.D.) display must read  
DOOR.”  
h. Close the main door and restart the dryer.  
i. Functional check of microprocessor controller (computer) board is complete.  
2. For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760)  
Theory Of Operation:  
Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds),  
the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open...as long  
as there is a call for heat. The DSI module will “LOCKOUT” if the gas burner flame is not sensed at the  
end of the trial for ignition period. The trial for ignition period will be repeated for a total of three (3)  
retries/trials (the initial try and two [2] more retries/trials). If the flame is not sensed at the end of the third  
retry/trial (inter-purge period of 30-seconds) the DSI module will “LOCKOUT” (L.E.D. flashes).  
A steady L.E.D. indicator indicates normal operation.  
No L.E.D. indicator indicates a power or an internal failure has occurred.  
QR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. For Direct Spark Ignition (DSI) System Models Manufactured With ADC Module Part No. 880815  
a. Upon completing installation of the  
replacement DSI module, reestablish power  
to the dryer.  
b. Start the drying cycle.  
c. The ignition DSI module’s light emitting  
diode (L.E.D.) indicator will light “red” for  
up to approximately 1.5-seconds (prepurge  
time).  
d. The module’s indicator light will then turn  
“green.” The gas valve will be energized and  
the ignitor probe will spark for approximately  
8-seconds. The burner flame should now be  
established.  
e. With the burner flame on, remove the flame  
sensor wire from the FS terminal of the DSI  
module.  
f. The burner flame must shut off and the  
ignition module must lockout with the DSI  
module’s indicator light “red.”  
g Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.  
h. The ignition module must proceed through the prepurge, with the indicator light “red,” the ignition  
trial time of approximately 8-seconds, with the indicator light “green,” and then proceed to lock out  
with the indicator light “red.”  
i. Functional check of the DSI module is complete.  
1) Replace the flame sensor wire from the FS terminal to the DSI module.  
QS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION XI  
BURNER/TUMBLER HI-LIMIT MANUAL  
RESET INSTRUCTIONS  
Both the top and bottom tumbler of this dryer is equipped/manufactured with a burner manual reset hi-limit and  
manual reset tumbler/lint chamber hi-limit thermostat. If either manual reset hi-limit thermostat is open prior to  
the start of the drying cycle, or during the drying cycle, the dryer will not recognize the open (tripped) state of  
the applicable basket/tumbler hi-limit thermostat and will start or continue through the drying cycle with no  
heat. The applicable open/tripped manual reset hi-limit must be reset manually. This hi-temperature condition  
may be caused due to a restricted exhaust, poor airflow, or improper burner operation. The burner manual reset  
hi-limit is located at the gas/valve manifold left burner chamber area. The tumbler manual reset hi-limit is  
located in the (right) lint chamber area.  
IMPORTANT  
This dryer is equipped with a burner  
hi-limit and tumbler/lint chamber hi-limit  
thermostat which must be reset manually.  
WARNING: Discontinue power to dryer  
before attempting to reset hi-limit.  
ADC P/N:114093  
QT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADC 113118 1- 11/11/99-50  
2- 11/29/99-200 3- 01/03/00-500  
4- 08/04/00-500 5* 09/11/00-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acu Rite Thermometer 617 User Manual
Addonics Technologies Blu ray Player DGBRC3 User Manual
Agri Fab Lawn Mower 45 03612 User Manual
Alcatel Lucent Network Card MDR 8000 User Manual
Allied Telesis Switch AT GS950 10PS User Manual
Axxess Interface Computer Drive OESWC 7552 STK User Manual
Badger Basket Baby Furniture 09970 User Manual
BC Speakers Portable Speaker DE950TN User Manual
Behringer DJ Equipment DX2000USB User Manual
Beko Refrigerator GNEV122X User Manual