Amcor Air Conditioner PVMB 12000E User Manual

Owner’s  
Manual  
Portable Air Conditioner  
Model PVMB-12000E  
It is important that  
you read these  
instructions before  
using your new  
purchase and we  
strongly recommend  
that you keep them  
in a safe place for  
future reference.  
Innovative AutoDrain NanoMist Technology™  
Patent Pending  
WWWꢀAMCORGROUPUSAꢀCOM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
THANK YOU ………………………………………………………………………2  
Energy SavingTips ……………………………………………………………2  
SPECIFICATIONS …………………………………………………………………3  
BEFORE USE ………………………………………………………………………4  
THE PVMB UNIT / PARTS …………………………………………………………5  
AUTODRAIN NANOMIST TECHNOLOGY™ ASSEMBLY ……………………6  
INSTALLATION OFTHE WINDOW KIT …………………………………………7  
Window Kit Installation ………………………………………………………7  
INSTALLATION ……………………………………………………………………8  
OPERATION ………………………………………………………………………9  
Turning the Unit On …………………………………………………………9  
Setting the Clock ………………………………………………………………9  
Setting theTemperature ………………………………………………………9  
Mode Button …………………………………………………………………9  
Fan Speed ……………………………………………………………………9  
To Set theTimer ………………………………………………………………9  
Canceling theTimer Function …………………………………………………11  
Sleep Mode ……………………………………………………………………11  
REMOTE CONTROL ………………………………………………………………12  
EMPTYINGTHE INTERNAL WATER CONTAINER ………………………………13  
MAINTENANCE…………………………………………………………………14  
Cleaning the Unit………………………………………………………………14  
Cleaning the Filter ……………………………………………………………14  
End of Season Storage…………………………………………………………14  
TROUBLESHOOTING ……………………………………………………………15  
WARRANTY ………………………………………………………………………18  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Thank You!  
Thank you for purchasing an AMCOR Portable Air Conditioner. AMCOR is a leading brand in indoor air  
treatment. We would like you to enjoy the many benefits this unit offers, so please read this  
manual carefully and take full advantage of the many advanced features that your AMCOR Portable Air  
Conditioner offers you.  
AMCOR has specialized in complete indoor environment control, manufacturing world-class air  
conditioners, dehumidifiers and air purifiers with innovative technology.  
In designing these advanced products, we have listened carefully to our customers and have passed  
their views on to our research and development laboratories.  
We wish you many years of enjoyable use.  
After reading this manual, please keep it in a safe place for future reference.  
Energy Saving Tips  
• Do not locate the air conditioner where furniture or other objects can obstruct the airflow.  
• Keep doors closed so cool air does not escape.  
• Keep the filters clean.  
Set the unit to maximum cooling and high speed fan initially, then adjust the unit to a comfortable setting.  
NOTE: Use the Temperature Control (UP/DOWN) to adjust Air Conditioner  
cooling to a desired level.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
PVMB-12000E  
Model  
Cooling Capacity  
12,000 BTU/h  
Cooling Power Consumption  
Power Supply  
Dehumidification  
Recommended room size  
Refrigerant  
1,100 W / 9.8 A  
115V / 60Hz / 1 Phase  
80 pints / Day  
Up to 400 sq. ft.  
R-22  
Compressor  
Rotary  
Fan Speeds  
3 (2 + 1Turbo)  
64º - 90º F  
Thermostat  
Timer  
0-24 hours  
Dimensions  
20”W x 16”D x 33”H  
75 lbs.  
Weight  
REMARKS:  
The cooling capacity of the unit may be affected by the  
height of the ceiling, quality of insulation, number of windows, etc.  
Subject to modifications without prior notice.  
Please refer to the rating label for greater precision.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before Use  
IMPORTANT!  
• Leave the unit in an upright position for at least 2 hours before use.  
• Always place the unit on an even surface.  
• The power cord has a built-in L.C.D.I. (Leakage Current Detection and Interruption)  
circuit breaker for added safety. If the power supply is interrupted, please press the reset  
button to reconnect the unit to the power source. The green light should be on.  
• Make sure the unit is connected to a correctly grounded power supply.  
• For proper operation, the unit must be vented to the outside.  
• Do not cover or obstruct the appliance inlet or outlet grilles.  
• To avoid the risk of shock, the product should never be used in bathrooms, shower rooms  
or in any other steamy or wet areas.  
• Always transport the unit in an upright position.  
• Do not sit or stand on the unit.  
• Do not place objects on the unit.  
• Do not touch the unit with wet/damp hands or when standing barefoot.  
• Drainage of the water container is required before moving the unit or  
putting it into storage.  
• If the electric socket is different from the plug provided, have a professionally qualified  
electrician replace the outlet with a suitable one. Avoid the use of adaptor plugs, multiple  
sockets and/or extension cords; if their use is necessary, ensure that they conform to the  
current safety regulations.  
• Do not pull the power cord or place it near a source of heat; always unroll it completely  
to avoid the possibility of dangerous overheating.  
• If the power cord is damaged, it must be replaced by a qualified person.  
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE  
INSTRUCTIONS ARE NOT FOLLOWED.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
The PVMB Unit  
Air Outlet  
Control  
Panel  
Upper air  
inlet  
Carrying  
Handle  
Exhaust air  
outlet  
Lower air  
inlet  
Water stopper/  
drain cap  
Caster  
Wheels  
Parts  
Air Filter (Pre-installed)  
O
N
/O  
FF  
U
P
FA  
N
D
O
W
N
Drain Pan  
Exhaust Hose  
Remote Control  
Insulation Strips  
Spiral Water Pipe  
with Connector  
Slide Bar  
Connector  
Adjustable Slide Bar  
Display  
COOLING  
FAN  
SLEEP  
08:15 HOURS: MINUTES  
75 ºF TEMPERATURE  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
AutoDrain NanoMist TechnologyTM Assembly  
Put spiral water  
pipe into hot air  
flexible hose.  
Attach Window  
Slide Bar  
Connector to  
Exhaust Hose by  
twisting as shown.  
1
3
5
7
2
4
6
Turn the  
connector  
90 degrees  
clockwise until it  
is locked in place.  
Connect the  
female half of the  
quick connector  
at the end of the  
spiral water pipe  
to the male part  
in the hot air  
outlet pipe.  
Assemble the  
hot air hose on  
the unit.  
Clip on the  
water atomizer  
at the end of  
the spiral pipe  
to the holder.  
Unfold flexible  
Only  
Required For  
Disassembly.  
hose with attached 8  
hose adapter  
connector, and  
snap into  
Window Slide Bar.  
In order to  
unlock the quick  
connector, push  
the tab and turn  
the connector  
90 degrees  
counter-  
clockwise.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
InstallationoftheWindow Kit
In order for this unit to function properly, it must be vented to the outside.  
Fitting the Exhaust Hose through a window is easy. Please see below.  
Adjustable  
Slide Bar  
Slide Bar  
Connector  
Exhaust  
Hose  
Window Kit Installation:  
1. Extend Exhaust Hose at least 6" and insert it into back of the unit, tightening  
into place by turning it clockwise.  
2. Attach Slide Bar Connector to the other end of the Hose by extending hose at  
least 6". Then tighten Hose by turning the Slide Bar Connector clockwise.  
3. Place Adjustable Slide Bar in the window and expand so it fits tightly.  
4. Mark Slide Bar to record width of the window.  
5. Apply Insulation Strips on top and bottom of Slide Bar.  
6. Reposition Slide Bar Connector in the window. Expand the Slide Bar to fit tight.  
Tighten the screws.  
7. Lower the window.  
8. Make sure Hose has no kinks.  
Slide Bar has 3 sections which allows installation in windows up  
to 48" in width.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
WARNING!  
The length of the exhaust pipe is specially designed according  
to the specification of this product.  
Do not extend it with your own hose, as this  
could cause the unit to malfunction  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
IMPORTANT: The air conditioner should be left in  
an upright position for at least two hours  
Reset Button  
A. Turning the Unit On:  
1. Plug the unit into a working electrical outlet.  
2. Make sure the green light on the plug is on.  
(If not, press the Reset button.)  
Test Button  
Green Light  
3. Press the unit’s ON/OFF Button on the LCD display.  
It may take a few minutes before cold air is dispersed.  
4. Adjust FAN Speed by pressing the FAN Button  
until the preferred fan speed is reached.  
5. Press the TIME Button to Set.  
B. Setting the TIME:  
1. Press the TIME button for 3 seconds to set the clock. The hour digits will flash.  
2. Press UP or DOWN to adjust the hour.  
3. Press the TIME button, the minute digits will flash.  
4. Press UP or DOWN to adjust the minutes.  
5. Press the TIME Button to Set.  
C. Setting the Temperature:  
To change the set temperature press the Up/Down button.  
The 2 digit display will indicate the set temperature.  
NOTE: Reaching the set temperature depends on the room and outdoor climatic conditions.  
The set temperature range is 64°F to 90°F.  
D. Mode Button:  
Press the Mode Button repeatedly until the icon representing the desired mode is  
displayed (Cool or Fan). On the LCD-display you will see:  
Cooling  
Fan only  
All settings will remain in memory unless power to the unit is shut off.  
At re-start unit will revert back to default temperature setting of 72°F.  
E. Fan Speed:  
To select the desired fan speed, press the fan button. Options are Slow, Medium, and Turbo.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Timer  
The TIMER function allows you to program the time the unit turns on and turns off.  
TO SET THE TIMER:  
• Press the TIME button briefly, the 2 hour digits will flash.  
• Press the UP or DOWN button to adjust the hour.  
• Press the TIME button again. The 2 minute digits will flash.  
• Press the UP or DOWN button briefly to adjust the minutes.  
• The TIME is set. After 10 seconds the time display returns.  
Programming the Timer for ON:  
• Perform the standard steps as described above.  
The linear time scale will be on between the  
OFF  
ON  
ON programmed times until 24:00.  
The flashing bar on the time scale indicates the  
real time and moves a segment ahead every  
30 minutes until it reaches the ON timer  
time, then the black segments in the linear time  
scale will disappear.  
Timer Example  
Programming the Timer for OFF:  
• Perform the standard steps as described above. The linear  
time scale will be on between the present time to the OFF  
programmed time. The flashing bar on the time scale indicates  
the real time and moves a segment ahead every 30 minutes until  
it reaches the OFF timer time, then the black segments in the  
liner time scale will disappear.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
The unit will operate daily according to the timer setting, unless changed.  
After a power failure, or after the unit has been unplugged, you will have to program the  
timer settings again.  
Canceling the Timer Setting  
In order to cancel the timer programming press the TIME button.  
Sleep Mode  
The SLEEP MODE gradually adjusts the temperature of the unit 4 degrees upward,  
over a 3 hour period, to meet the needs of a body at rest.  
To activate the SLEEP MODE:  
• Ensure the unit is operating in Cool Mode.  
• Set the desired starting temperature.  
• Press SLEEP MODE button.  
• In sleep mode fan will operate in low speed.  
• To cancel this function press SLEEP MODE button again.  
Shutting Off the Blue Light on Control Panel  
Normally there is a blue light on the LCD display.  
To shut it off, press the UP and DOWN push buttons at the same time.  
The blue backlight will blink twice, and after 3 seconds, will go off.  
Pressing any of the push buttons will re-light the blue backlight.  
Auto Grill Function  
1. When unit is being connected (plugged in) to the electricity the louvers open and  
close (and stay closed).  
2. When the ON button is pressed, the louvers open to the maximum and return to an|  
angle of 75º above the upper plane of the louvers housing (AUTO GRILL).  
3. When the swing push button is pressed, the louvers swing up & down between  
30º and 80º above the upper plane of the louvers housing (SWING).  
4. When the louvers are moving in the swing function, by pressing the swing push button,  
the louvers stop moving and remain in the same position (SWING). This enables the  
user to direct the airflow vertically via the remote control.  
5. When the OFF push button is pressed, the louvers close (AUTO GRILL).  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
To Operate the Remote Control:  
Insert batteries by pulling down on front cover (See fig. 1).  
Be sure the remote is pointed at the unit at all times.  
1. To Set the Clock:  
10:09  
72  
• Press the TIME button for 3 seconds.  
Fϒ  
• The hour digits will flash. Press UP or DOWN to adjust the hour.  
• Press the TIME button. The minute digits will flash.  
Press UP or DOWN to adjust the minutes.  
ON/OFF  
UP  
FAN  
DOWN  
• Press the TIME button when finished.  
TIME  
2. To Turn Unit ON:  
• Press the ON / OFF button  
SLEEP  
MODE  
3. To Adjust TEMPERATURE:  
SWING  
• Adjust temperature using the UP / DOWN buttons  
4. To Adjust FAN SPEED:  
• Press FAN button to select speed.  
5. To Set the TIMER:  
A. SET START TIME  
• Press timer ON button and set the On hour using  
the UP and DOWN buttons.  
• Press timer ON button and set the minutes using  
the UP and DOWN buttons.  
Slide  
Cover  
Down  
• Press timer ON to finish.  
B. SET OFF TIME  
• Press the timer OFF button and set the Off hour using  
the UP and DOWN button.  
• Press the timer OFF button and set the minutes using  
the UP and DOWN buttons.  
• Press timer OFF to finish.  
fig.1  
6. To Set SLEEP MODE:  
• Make certain unit is operating in Cool Mode.  
• Set the desired starting temperature.  
• Press SLEEP MODE button.  
7. To set Auto Grill Mode:  
• Press the SWING button for moving louvers  
• Press the SWING button again to stop louvers from moving  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Emptying the Internal Water Container  
Note: There are two instances where draining the internal water container may be recommended:  
1. In the unlikely event that the Container Full Light on the LCD display flashes  
2. Prior to storage of unit.  
When the internal water container is full, the back light on the LCD display flashes.  
The unit will shut off automatically, and must be drained before it will restart.  
To Drain the Unit:  
• Switch off the unit and remove the plug from the wall socket.  
• DO NOT MOVE THE UNIT. Doing this can result in water  
leakage, damaging your floor or carpet.  
• Place the drain pan on the floor under the drain cap.  
• Remove the drain cap and the rubber stopper from the  
drain, and let the water run out. Partially fill the drain pan,  
replace the rubber stopper, and empty the drain pan.  
This procedure must be repeated until the unit is empty.  
• Replace the rubber stopper and drain cap.  
Put plug into the wall socket, and switch the unit on.  
The warning signal should be off.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
Always unplug the unit from the wall before performing any maintenance.  
• Make sure the unit is drained before moving.  
Cleaning the Unit:  
• Only use a soft damp cloth.  
• Never use chemicals, oil-based products, detergents, or other cleaning solutions.  
These could damage the cabinet.  
Cleaning the Upper Filter:  
• Slide out the filter holder  
from the unit.  
• Separate the filter fixer from  
the filter holder (see fig. 1).  
• Remove the active carbon filter (black) and slide out the 3M™ High Air Flow filter (white).  
• To clean filters, vacuum with standard vacuum cleaner.  
• Insert the active carbon filter into the filter holder (see fig. 2).  
• Insert the 3M™ High Air Flow filter into the filter holder (see fig. 3).  
• Fix the filters by reassembling the fixer into the filter holder (see fig. 4).  
Cleaning the Lower Filter:  
• Vacuum with standard vacuum cleaner.  
NOTE:  
• Before storage be sure filters are clean and dry.  
• Should you need to replace filters, contact Amcor for replacement.  
• The screen filter must always be used.  
• The 3M™ High Air Flow filter should be cleaned periodically. Both filters can be vacuumed.  
IMPORTANT: NEVER operate the unit without a filter.  
End of Season Storage:  
• Unplug the unit.  
• Drain the condensed water COMPLETELY.  
• Clean the upper and lower filter.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Never try to repair or dismantle the air conditioner yourself. Tampering with the unit may  
result in the loss of warranty and can endanger the user and property.  
Problem  
Cause  
Solution  
Close doors and windows.  
Clean or replace filter.  
Remove blockage.  
The Air Conditioner Windows or doors are open.  
Does Not Function  
Properly  
The filter is dirty.  
Air inlet or air outlet is blocked.  
Room temperature lower than  
the selected value.  
Lower temperature selected.  
The Unit Does  
Nothing  
The overheat protection is acti-  
vated.  
Wait 3 minutes until temperature has  
decreased, then turn on again.  
No power supply.  
Make sure outlet works.  
Be sure Green Light is on (L.C.D.I. Plug)  
Press Re-start button.  
Water container is full. The LCD Drain the Unit.  
light is flashing  
Timer Function Set.  
Deactivate the Timer Function.  
The Unit is Noisy  
Unit is not standing on a level  
surface.  
Place on an even surface.  
The Remote Control Distance too great.  
Does Not Function  
Make sure the remote is aimed at the  
control panel.  
Remote control signal not detect- Control is aimed at the control panel.  
ed by control panel.  
Batteries are dead.  
Replace the batteries.  
If you have any questions regarding the operation of the this product  
please contact AMCOR at 1-866-361-2233  
REPLACEMENT FILTERS:  
To purchase Replacement Filters for this unit, contact AMCOR at  
1-866-361-2233 and request model number PVMB-12000E  
If this product is defective or not working properly,  
please DO NOT return to your retail store.  
Please contact Amcor for service or technical assistance  
Amcor Inc.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Don’t forget to register your Amcor purchase online,  
and view our broad selection of innovative products.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
One Year Limited Warranty  
(5 Years for Compressor Only)  
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the United  
States that the Amcor product with which this warranty is enclosed is free from defects in materials  
and workmanship.  
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair, free  
of charge, all defective parts, for a period of one (1) year from date of original purchase. (5 years for  
Compressor Only) ANY IMPLIED WARRANTY OF MERCHANTABILITY IS SIMILARLY LIMITED  
TO ONE (1) YEAR -(5 years for Compressor Only) FROM DATE OF ORIGINAL PURCHASE AND  
NO ACTION BASED UPON ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OTHER-  
WISE MAY BE COMMENCED AFTER EXPIRATION OF ONE (1) YEAR -(5 years for Compressor  
Only) FROM DATE OF ORIGINAL RETAIL PURCHASE. Some states do not allow limitations on  
how long an implied warranty lasts, so the above limitation -(5 years for Compressor Only) may not  
apply to you.  
The provisions of this warranty shall not apply to any product which in Amcor’s judgment has been  
(1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose for which it was  
not designed, or (4) repaired or altered in any way that adversely affected its performance or reli-ability.  
To obtain warranty service, the defective product or part must be shipped or delivered to: Amcor’s  
authorized service center. All postage, insurance and shipping charges are the responsibility of the  
Purchaser and are not included in this warranty.  
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY  
OTHER ( LIABILITY IN CONNECTION WITH ITS PRODUCTS, THERE ARE NO WARRANTIES  
WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. NO RESPONSIBILITY  
IS ASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES THAT MAY RESULT FROM  
THE USE OF AN AMCOR PRODUCT, NOR FOR THE DAMAGES DUE TO ACCIDENT, ABUSE,  
LACK OF RESPONSIBLE CARE, THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT,  
LOSS OF PARTS, OR USE AT A VOLTAGE OTHER THAN SPECIFIED. Some states do not allow  
the exclusion of limitation of incidental or consequential damages, so these limitations may not  
apply to you.  
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained  
from or by service at any service center other than Amcor’s authorized service center.  
This warranty gives you specific legal rights, and you may also have other rights which vary from state  
to state.  
Product: AMCOR Plasma 120000 Portable Air Conditioner  
Date Purchased:__________________________________ Production Code:________  
Model: PVMB-12000E  
Dear Customer: Please keep this warranty for your record. DO NOT return it.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acer Laptop N260G User Manual
ADS Technologies Network Card version 52b1 User Manual
Agilent Technologies Yogurt Maker 4291B User Manual
Allied Telesis Switch PN 613 User Manual
American Aldes Ventilation Hood DHV 150H User Manual
American Audio Stereo Amplifier Vplus Series User Manual
American Standard Hot Tub 2394 User Manual
Audiovox Remote Starter PRO 9171FT User Manual
Axis Communications Security Camera P3365 V User Manual
Behringer TV Cables UFO202 User Manual