Amana Range AGR3300XD User Manual

Gas Range  
PRODUCT MODEL NUMBERS  
INSTALLATION CLEARANCES  
AGR3300XD  
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop  
depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop  
height.  
If the cabinet depth is greater than 24" (61.0 cm), oven frame must  
extend beyond cabinet fronts by ¹⁄₂" (13.0 mm) minimum.  
IMPORTANT: If installing a range hood or microwave hood  
combination above the range, follow the range hood or microwave hood  
combination installation instructions for dimensional clearances above  
the cooktop surface.  
GAS SUPPLY REQUIREMENTS  
Natural gas:  
This range is design-certified by CSA International for use with Natural gas or,  
after proper conversion, for use with LP gas.  
This range is factory set for use with Natural gas. See “Gas Conversions”  
section. The model/serial rating plate located behind the storage drawer on  
the right-hand side oven door frame has information on the types of gas that  
can be used. If the types of gas listed do not include the type of gas  
available, check with the local gas supplier.  
LP gas conversion:  
Conversion must be done by a qualified service technician.  
No attempt shall be made to convert the appliance from the gas specified on  
the model/serial rating plate for use with a different gas without consulting the  
serving gas supplier. See “Gas Conversions” section.  
D
B
C
Gas Supply Line  
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A  
smaller size pipe on longer runs may result in insufficient gas supply. With  
LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas  
suppliers determine the size and materials used in the system.  
NOTE: Pipe-joint compounds that resist the action of LP gas must be used.  
Do not use TEFLON®† tape.  
A
E
G
Flexible metal appliance connector:  
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to  
152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance  
connector may be used for connecting range to the gas supply line.  
K
F
J
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe  
threads of the inlet to the appliance pressure regulator.  
Do not kink or damage the flexible metal tubing when moving the range.  
I
Rigid pipe connection:  
H
The rigid pipe connection requires a combination of pipe fittings to obtain  
an in-line connection to the range. The rigid pipe must be level with the  
range connection. All strains must be removed from the supply and fuel  
lines so range will be level and in line.  
Must include a shutoff valve:  
The supply line must be equipped with a manual shutoff valve. This valve  
should be located in the same room but external to the range opening, such  
as an adjacent cabinet. It should be in a location that allows ease of opening  
and closing. Do not block access to shutoff valve. The valve is for turning on  
or shutting off gas to the range.  
A. 18" (45.7 cm) min. clearance upper side cabinet to countertop  
B. 13" (33 cm) max. upper cabinet depth  
C. 30" (76.2 cm) min. opening width  
D. For minimum clearance to top of cooktop, see NOTE*.  
E. 30¹⁄₈" (76.5 cm) min. opening width  
F. 17" (43.2 cm)  
†®TEFLON is a registered trademark of E.I. Du Pont Nemours and Company.  
OVERALL DIMENSIONS  
G. This shaded area recommended for installation of rigid gas pipe.  
H. 2" (5.1 cm)  
I. 4" (10 cm)  
J. 2" (5.1 cm)  
K. 2" (5.1 cm) min. clearance from both sides of range to side wall  
or other combustible material.  
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal  
cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant  
millboard covered with not less than No. 28 MSG sheet steel, 0.015"  
(0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020"  
(0.5 mm) copper.  
36"  
26³⁄₄"  
(67.9 cm)  
(91.4 cm)  
30" (76.2 cm) minimum clearance between the top of the cooking  
platform and the bottom of an uncovered wood or metal cabinet.  
42"  
(106.7 cm)  
IMPORTANT: Some cabinet and building materials are not designed to  
withstand the heat produced by the oven for baking and self-cleaning.  
Check with your builder or cabinet supplier to make sure that the  
materials used will not discolor, delaminate or sustain other damage.  
24¹⁄₄"  
(61.6 cm)  
29⁷⁄₈" (75.9 cm)  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10325493A  
1/17/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Actiontec electronic Network Router GE344000 01 User Manual
Addonics Technologies Computer Drive AD5SAPM User Manual
ADTRAN Network Card TSU LT User Manual
ADT Security Services Home Security System BHS 4000A User Manual
Aiphone Intercom System JB DV User Manual
Alpine DVD Player IVA D105 User Manual
American Standard Furnace Condensing Gas Furnaces Fan Assisted Combustion System User Manual
Audiovox Radio P 963ESP User Manual
Avital Remote Starter 4113 User Manual
Axor Indoor Furnishings 92720000 User Manual