Amana Microwave Oven AMV1154BA User Manual

®
Over the Range Microwave Oven  
CABINET OPENING DIMENSIONS  
PRODUCT MODEL NUMBERS  
AMV1154BA  
AMV5164BA  
AMV5164BC  
Bottom edge of  
cabinet needs  
to be 33" or  
more from the  
cooking  
Electrical: Product rating is 120 volts AC, 60 Hz, 14.5 amps (13 amps  
CANADA) and 1.65 kilowatts (1.5 kilowatts CANADA). This product must be  
connected to a supply circuit of the proper voltage and frequency. Wire size  
must conform to the requirements of the National Electrical Code or the  
prevailing local code for this kilowatt rating. The power supply cord and  
plug should be brought to a separate 20-ampere branch circuit single  
grounded outlet. The outlet box should be located in the cabinet above the  
microwave oven. The outlet box and supply circuit should be installed by a  
qualified electrician and conform to the National Electrical Code or the  
prevailing local code.  
16-½ "  
surface  
33"min.  
2"  
Backsplash  
PRODUCT DIMENSIONS  
C
A
NOTES:  
B
• The space between the cabinets must be 30" (76.2 cm) wide and free  
of obstructions.  
• This microwave oven is for installation over ranges up to 33" (83.8 cm)  
wide.  
• If you are going to vent your microwave oven to the outside, see  
Venting Requirements for exhaust duct preparation.  
When installing the microwave oven beneath smooth flat cabinets be  
careful to follow the instructions on the top cabinet template for  
power cord clearance.  
Width (A)  
29-7/8"  
(75.9 cm)  
29-7/8"  
(75.9 cm)  
29-7/8"  
(75.9 cm)  
Depth (B)  
15"  
(38.1 cm)  
15-1/4"  
(37.7 cm)  
15-1/4"  
(37.7 cm)  
Height (C)  
16-1/2"  
(41.9 cm)  
16-1/2"  
(41.9 cm)  
16-1/2"  
(41.9 cm)  
AMV1154BA  
AMV5164BA  
AMV5164BC  
VENTING REQUIREMENTS  
NOTE: It is important that venting be installed using the most direct route  
and with as few elbows as possible. This ensures clear venting of exhaust  
and helps prevent blockages. Also, make sure dampers swing freely and  
nothing is blocking the ducts.  
For best performance, use no more than three 90° elbows.  
To calculate the length of the system you need, add the equivalent length  
for each vent piece used in the system. See the following examples:  
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should  
be used.  
The total length of the vent system including straight vent, elbow(s),  
transitions and wall or roof caps must not exceed the equivalent of 140 ft  
(42.7 m) for either type of vent.  
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following  
carefully.  
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)  
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)  
The following chart describes an example of one possible ductwork installation.  
The following chart describes an example of one possible ductwork installation.  
DUCT PIECES  
EQUIVALENT  
LENGTH*  
NUMBER  
USED  
EQUIVALENT  
LENGTH  
DUCT PIECES  
EQUIVALENT  
LENGTH  
NUMBER  
USED  
EQUIVALENT  
LENGTH  
x
=
x
=
Roof Cap  
40 Ft.  
(12.2 m)  
x
(1)  
(1)  
(2)  
=
40 Ft.  
(12.2 m)  
Roof Cap  
24 Ft.  
(7.3 m)  
x
(1)  
(1)  
=
24 Ft.  
(7.3 m)  
3 Ft. Straight Duct  
(3¼" x 10"  
Rectangular)  
3 Ft.  
(1 m)  
x
x
=
=
3 Ft.  
(1 m)  
12 Ft. Straight Duct  
(6" Round)  
12 Ft.  
(3.7 m)  
x
x
=
=
=
12 Ft.  
(3.7 m)  
90° Elbow  
10 Ft.  
(3 m)  
20 Ft.  
(6.1 m)  
Rectangular-to-Round 5 Ft.  
(1.5 m)  
(1)  
5 Ft.  
(1.5 m)  
Transition Adaptor*  
Equivalent lengths of duct pieces are based on actual  
tests and reflect requirements for good venting  
performance with any vent hood.  
Equivalent lengths of duct pieces are based on actual  
tests and reflect requirements for good venting  
performance with any vent hood.  
Total Length  
=
63 Ft.  
(19.2 m)  
Total Length  
41 Ft.  
(12.5 m)  
NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be  
prepared at the time it is constructed by leaving enough space between the wall studs to accommodate  
exhaust.  
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have  
to be cut to fit, using tin snips, in order to allow free movement of the damper.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8101P679-60  
09-15-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

ADC Network Card 105968AE User Manual
Advantech Computer Monitor PPC A84 A120 X5X User Manual
AEG Washer 73742 User Manual
Aiphone Musical Table AI SSV User Manual
Aiwa CD Player XP R970 User Manual
Allied International Digital Camera GX1660 User Manual
Allied Telesis Power Supply AT FAN01 User Manual
Audiovox Satellite TV System SRSIR 001FM SRSIR 001FMR User Manual
Audiovox Speaker AVW100 User Manual
Behringer Speaker GEQ3102 User Manual